Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | ₹8.3 L Quoted ₹9.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹9.4 L+₹7,390 (0.79%)Rejected-AOC HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | ₹9.4 L+₹7,390 (0.79%) | L2 | Rejected-AOC L2 |
| 3 | L3₹9.5 L+₹17,720 (1.90%)Rejected-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | ₹9.5 L+₹17,720 (1.90%) | L3 | Rejected-AOC L3 |
| 4 | L4₹9.5 L+₹18,225 (1.96%)Rejected-AOC VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | ₹9.5 L+₹18,225 (1.96%) | L4 | Rejected-AOC L4 |
| 5 | L5₹9.7 L+₹42,635 (4.58%)Rejected-AOC 240 1 A RAI COLONY CIVIL LINES JHANSI 284001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | ₹9.7 L+₹42,635 (4.58%) | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹19,980
Closing Date
31 Aug 2022, 6:00 pmClosed
AGE I TALBEHAT
LAKE VIEW CAMP MIL STN TALBEHAT 284125
REPAIR/REPLACEMENT OF OLD U/S GI PIPE/CPVC PIPE AND CONNECTED ITEMS AT ZONE 9A, 06 AND 17 AT MIL STN TALBEHAT
2022_MES_542623_1
AGE(I)/TBT/TOK-29/2022-23
Open Tender
Pipes and Pipe related activities
Item Rate
180 days
MIL STN TALBEHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I TALBEHAT
₹19,980
Yes
8 Sept 2022
2 Aug 2022
2 Sept 2022
10 Aug 2022
31 Aug 2022
17 Aug 2022
Amount
Excavation in soft/loose soil trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out incl old U/s cable cover of any type , taking out/laying/cleaning/repairing of CI/GI pipe line, cable etc including making good to disturbed surfaces complete all as specified and directed.
Returning, filling in & including spreading, leveling & well ramming in layers not exceeding 25 cm thick as in soft/loose soil complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 mtr above ground level complete all as specified and directed.
Demolition of hard standing/road for crossing of pipe line as per the authorized width for taking out/laying/cleaning/repairing of CI/GI pipe lines all as directed including making good the disturbed surfaces and cut to match with the existing surface either with bituminous macadam or with PCC 1:2:4, type B-2(using 40mm graded crushed stone aggregate) complete all as specified and directed.
Taking up unserviceable CI/DI rusted/ broken pipe line (including all fittings) with spigot and socket/ Flanged ends for reusing and removal of unserviceable part from the site including burning out joints and recovering lead complete all as specified and directed for the following sizes/bores of pipes:-. (Earth work shall be measured and paid separately).
200mm bore dia
150mm bore dia
100mm bore dia
80mm bore dia
Laying only in trenches DI/ CI pipe with spigot and socket ends complete after cleaning properly/thoroughly & removal of all blockage removing all silt and deposited organics inside using bamboo or rod with brush complete all as specified and directed for the following sizes/bore of pipes :-
200mm bore dia
150mm bore dia
100mm bore dia
80mm bore dia
Supply & laying in trenches ductile iron (DI) pipe with spigot and socket ends centrifugally cast class 'K-7' in any length laid in trenches including necessary jointing material complete and testing all as specified and directed for 100mm dia /bore of pipes (DI/CI fittings shall be measured and paid separately).
Supply and laying DI pipe with flanged ends centrifugally cast class 'K-9' laid in trenches/ wall / overhead tank of any length of 150mm dia/bore including necessary jointing material complete and testing all as specified and directed (CI/CI fittings shall be measured and paid separately).
Taking up or down steel water tubing and connections including clearing the pipes free from scaling for reusing and removal of unserviceable part complete all as directed for the following sizes :- Note :-Excavation will be measured and paid separately
80 mm dia bore
50mm dia bore
40mm dia bore
25 mm dia bore
20 mm dia bore
15 mm dia bore
Relaying/ refixing of old steel tubing and connection in new or old position including necessary cuttings, threading and new fittings such as bends, elbows, socket nipples, tapers, and reducers etc all as specified and directed:-
80 mm dia bore
50mm dia bore
40mm dia bore
25 mm dia bore
20 mm dia bore
15 mm dia bore
Supply and lay steel water tubing GI medium grade ISI marked with all necessary fittings and fixtures (Socket, elbow, bend, nipple, union etc) laid in trenches or fixed to wall etc complete for the following sizes:- Make: Jindal/Prakash/Swastik Note :- Excavation and earth work will be measured and paid separately:-
80 mm dia bore
50mm dia bore
40mm dia bore
25 mm dia bore
20 mm dia bore
15 mm dia bore
M&L for actual detecting the leakage of existing CI /DI pipe any type including excavation upto one cum and repairing the joint with new lead & jute/wool refixing after testing for leakage proof pipe line and including returning filling and making good to disturbed surface complete for following bore of CI pipe line :-
200 mm dia
150 mm bore
100 mm dia
80 mm dia
All as per item No. 12 here-in-before but by using old retrieved lead for the following bore of CI pipe line
150 mm bore
100 mm bore
80 mm bore
M&L for rubber gasket joint suitable for DI/CI pipe and fittings with size of nuts, washer & bolts etc complete all as specified and directed for the following sizes :-
200 mm bore
150 mm bore
100 mm bore
M&L for upto 150mm bore Ductile iron (DI)/ Cast iron (CI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs including taking up old unserviceable fitting complete all as specified and directed.
M&L for 200mm bore ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs including taking up old unserviceable fitting complete all as specified and directed.
M&L for actual detecting the leakage of existing GI pipe line any type laid in trenches/ wall/ floor including excavation upto one cum taking out existing pipeline and repair including replacement of GI fitting such as tee, socket, reducer, elbow, union, etc complete and refixing after testing for leakage proof pipe line and including returning filling and making good to disturbed surface complete for following bore of GI pipe line :-
40 to 80 mm GI pipe
15 to 25 mm GI pipe
S&F Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves:- Make : Zoloto/Seico/Jindal/Upadhaya/Venus
50mm bore
40mm bore
25mm bore
20mm bore
15mm bore
S&F bib tap PTMT15mm dia including taking out unserviceable tap of 15mm dia complete all as specified and directed.
S&F bib tap PTMT 20mm dia including taking out unserviceable tap of 20mm dia complete all as specified and directed.
Supply, fixing, jointing and testing in repair of cast iron sluice valve class I (ISI MARKED) PN-1 type latest IS 14846-2000 flanged ends, drilled having stainless steel spindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etc complete including taking down unserviceable sluice valve complete all as specified and directed for following bore of CI pipe line :-
200 mm dia bore
150mm dia bore
100mm dia bore
80mm dia bore
S&F in repair CPVC male brass threaded adopter for CPVC Pipe outer diameter 20mm all as specified and directed
S&F in repair CPVC female brass threaded adopter for CPVC Pipe outer diameter 20mm all as specified and directed
Dismantling old broken / damaged valve pit chamber of size 1050mm x 1050mm x 1050mm (internal dimension) complete including excavation and earth work, PCC 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in cement mortar 1:6, plastering in cement mortar 1:4 (internally) and including 3mm thick mild steel sheet cover and painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Note :- Earth and PCC work
All as per item No 24 above but size of valve chamber is 900 x 900 x 900 mm (internal) and all as specified and directed.
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
m/s bobby enterprises
HARNAM SINGH ANIL SINGH
M/S A.R BUILDERS
M/s BRIJ KUMAR RAI
M/s Indu Enterprises
ROHIT ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .