Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC 1ST FLOOR GURJEET MARKET DHANGU ROAD | L1 | Accepted-AOC Lowest | |
| 2 | L2₹13.2 L+₹1.8 L (15.8%)Rejected-AOC | L2 | Rejected-AOC More Than Lowest | |
| 3 | L3₹15.6 L+₹4.1 L (36.3%)Rejected-AOC | L3 | Rejected-AOC More Than Lowest |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
5 Oct 2020, 6:00 pmClosed
GE (NORTH) MAMUN
GE (NORTH) MAMUN C/O 56APO
REPAIR / REPLACEMENT OF LIGHTING PROTECTION AND OTHER MISC E/M WORKS UNDER AGE E/M-I OF GE NORTH MAMUN.
2020_MES_375078_1
GE(N)/M- /2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (N) Mamun
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(NORTH) MAMUN
₹24,000
Yes
27 Nov 2020
5 Sept 2020
7 Oct 2020
5 Sept 2020
5 Oct 2020
21 Sept 2020
Amount
Supply, and fixing of aluminium strip for lightening conductor of size 25 x 3.15 mm with saddles and fixing screws on roof/wall with porcelain insulators all as specified and as directed.
M&L for galvanised Galvanised iron strip 32 x 6mm buried in ground including connecting nut, bolt and inter linking with earth point with protection pipe and all as specified and as directed .
S&F termination rod single pointed made of aluminium rod 12 mm dia and 300 mm long fixing on roof with aluminium strip all as specified and as directed.
M&L for test point terminal block made of gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia long hex screws and all as specified and as directed.
S&F 32 mm light grade steel tubing along the fitting grouted on floor with PCC (1:3:6) at junction point of aluminium strip to mount the air termination rod of 12 mm dia 300 mm long to arrest the lightening and all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI light grade pipe 15mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed.
M&L for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron strip of 32x6mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI light grade pipe 40mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed.
Repair and servicing of DG set consisting of normal repairs, including repair of defective/ wornout parts by new spares such as filters, gaskets, V belts, Engine oil, rubber hoses, worm drive clamps, nuts & bolts and cleaning of alternator with vaccum cleaner including greasing of bearings etc for capacity upto 63 KVA DG Set .
Diesel filter element, primary and secondary suitable for DG set upto 63KVA
Oil filter element suitable for DG set upto 63KVA
Air filter element suitable for DG set upto 63KVA
Fan belt suitable for DG set upto 63KVA
Rubber hosepipe set suitable for DG set upto 63KVA
Battery leads set copper conductor 70 Sqmm 1.25 mtr long suitable for DG set upto 63KVA
Engine oil 2040w Make :- Indian oil/ Hindustan petrolium / Castrol.
Coolant
Radiator servicing complete of DG set upto 63KVA.
Cleaning of fuel tank both internally and externally of DG set upto 63KVA.
Fuel injection pipe set suitable for DG set upto 63KVA
Repair/overhauling of self starter 12 volts of DG upto 63KVA including replacement of carbon brushes, bearing, and warnishing complete.
Fuel pipe steel suitable for DG set upto 63KVA
Scrapping and painting of DG set.
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Excavation in trenches in Sof / loose soil n. exc. 1.5 Mtr in width and exc. 1.5 Mtr but not exc. 3.00 Mtr In depth and getting out all as required for laying of cable/ poles complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed.
Returing filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
M&L for Sub Class 'B' bricks old size, laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required as in protection of cable complete all as specified and directed.
Laying only for Sub Class 'B' bricks old size, laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required as in protection of cable complete all as specified and directed.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable all as directed. Note: Punned thickness of 18cm will be measured .
M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) for foundation bed of pole including form work complete all as specified.
M&L for cement concrete 1:3:6 type C1 ( using 20mm graded stone aggregate) for foundation of pole or repair of road/floor cutting including form work complete all as specified.
M&L for cement concrete 1:2:4 type B1 ( using 20mm graded stone aggregate ) in coping of poles studs including form work etc complete all as specified.
Dismantling and taking down old UNSV concrete pole/Strut any size and removal from site. Distance within 50 mtr for side or reuse complete all as specified and directed.
Dismantling and taking down old UNSV steel pole/Strut any size and removal from site. Distance within 50 mtr for side or reuse complete all as specified and directed..
Material and labour for prestressed cement concrete pole 9 mtr long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10 complete, erected truly in vertical position and painting the poles with synthetic enamel paint upto 1.5 mtr from the coping above the ground level with alternate layer of 30 cm width with black and yellow paint complete all as specified and directed.
Material and labour for erection of steel tubular swaged pole 9mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative green & white strips of 30 cm height upto 1.5 mtr above ground level all as required at site complete all as specified and directed.
Taking down carefully aluminium conductor of any size from OH Lines (running on 9/11 poles) after unbinding from insulators for replacement of multijointed / undersize conductors or restreching the serviceable conductor complete all as specified and directed..
Restringing and restretching aluminium conductor reterived under item Srl 37 above including necessary binding with insulators using alunimium binding wire, connections of incoming and out going cables complete all as specified and directed.
M&L for ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed.
Restretching aluminium conductor or GI wire on existing over head lines (running on 9/11 Mtrs pole) without removing including unbinding from insulator and rebinding to insulator using aluninium binding wire , connections of incoming and out going cables, binding with spacers where required, complete all as specified. (Note ;- For measurement length of each conductor shall be taken seperately.)
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use complete all as specified and directed .
Fixing only cross arm with cross arm supports/ angle iron induct frame etc incl nut, bolt, washer, welding, bending, hot or cold drilling holes for insulators bolts in any size or shape complete all as specified and directed.
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Dismantling and taking old/UNSV stay assembly including Stay wire and insulator complete all as specified and directed .
M&L for stay assy complete with MS stay plate of size 300x300x6mm thick, stay rod 20 mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I complete all as specified and directed.( Excavation, PCC, saty wire and loop type insulators will be measured separately).
M&L for repair and replacement of galvanized stay strand of size 7/4 mm complete all as specified and directed.
M&L in replacement of loop type insulator large size with overall dimensions (90 x140) mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified and directed.
Dismantling insulators of any type, any size all as directed.
Fixing of shackle type insulators of 100mm high, 115mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified, required at site or directed.
Fixing only Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 1100 volts grade complete all as specified and directed.
M&L for shackle type insulators of 100 mm high, 115 mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified, required at site complete all as specified and directed.
M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 1100 volts grade complete all as specified and directed.. Make : BHEL/ Jaipuria/ Rashtriya.
M&L for Disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for conductors, working pressure 1100 volts complete all as specified and directed.
Taking out from trenches or wall/ pole or pipe cable LT 1100 volts grade heavy duty , armoured with steel strip of wire , with stranded aluminium conductor of any size upto 35 Sqmm, any core , for rectification of faults or replacement. Seggregating serviceable cable and unserviceable length by meggering or any other suitable and recommended method. Removing unserviceable from site and keeping aside serviceable for reuse at same location or any other location complete all as rquired at site or directed. (Earth work will be measured and paid separately under respective item).
All as per Srl Item 54 above but of size 50 Sqmm to 70 Sqmm complete all as specified and directed.
All as per Srl Item 54 above but of size 95 Sqmm to 120 Sqmm complete all as specified and directed.
Laying only in trenches or fixed to wall/pole or passing through pipe cable LT 1100 Volts grade heavy duty, armoured with aluminium conductor of size up to 50 Sqmm any core complete all as specified and directed.. (Serviceable cables retrieved against srl item above will be reused or will be provided by department).
All as per Srl Item 57 here in above but of size 70 Sqmm to 95 Sqmm, 3.5 Core complete all as specified and directed.
All as per Srl Item 57 here in above but of size 95 Sqmm to 120 Sqmm, 3.5 Core complete all as specified and directed.
Taking down street light fitting or flood light, garden lights fitting any type and rating from poles, walls or any other indicated situation/location including removal of unsv GI bracket pipe as directed, after disconnecting electrically. and unservicable fittings and accessories from site complete all as specified and directed..
Supply, fixing, testing & commisioning of high-quality finless, MC PCB type LED Street Light with a minimum system lumen of 5400 Lm and system wattage not exceeding 45W with efficacy not less than 120 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI> 70. The housing should be of non-corrosive high-pressure die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF >0.95. LM-79 and LM-80 test report with 50000 buring hours LED life @L70 from NABL lab shall be provided. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with and IK-08 rating. Optical and control gear compartments shall be maintainable/replaceable . The Luminaire should have a 20 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The LED used in the luminaire shall be SMD type only. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Potted drivers should be Isolated with inbuilt not less than 4 KV surge protection & not a printed circuit board without casing mounted inside the luminaire. Suitable arrangement to be made for fixing of light in existing bracket. The Luminaires shall be aesthetically appealing and should have no extremal visible fins. LED's, driver and fixture should be BIS approved and same make, complete making connections with street light terminal box with and including PVC insulated & sheathed single core cable of size 1.5 Sqmm 3 run for phase, earth,neutral complete all as spd and directed. Make of LED light fitting:- Philips Cat No : BRP056 LED 54 CW SLA PSU GR SPD or equivelent in Osram/ Bajaj/ Wipro
Supply, fixing, testing & commisioning of high-quality, MC PCB type LED Street Light with a minimum system lumen of 11250 Lm and system wattage not exceeding 90W with efficacy not less than 125 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI : 70. The housing should be of non-corrosive high-pressure single piece compartment die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF> 0.95. LM-79 and LM-80 test report with 50000 buring hours LED life @L70 from NABL lab shall be provided. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 07. Optical and control gear compartments shall be openable with Toggles and should be maintainable/ replaceable. The Luminaire should have a 20 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire shall be openable with toggles, the luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The LED used in the luminaire shall be SMD type only. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Potted drivers should be Isolated with inbuilt not less than 4 KV surge protection & not a printed circuit board without casing mounted inside the luminaire. Suitable arrangement to be made for fixing of light in existing bracket. The Luminaires shall be aesthetically appealing and should have no extremal visible fins. LED's, driver and fixture should be BIS approved and same make, complete making connections with street light terminal box with and including PVC insulated & sheathed single core cable of size 1.5 Sqmm 3 run for phase, earth,neutral complete all as spd and directed. Make of LED light fitting:- Philips Cat No : BRP409 LED 115 or equivelent in Osram/ Bajaj/ Wipro/GM
Supply, fixing, testing & commisioning of LED based Flood light, housing made up of pressure die cast aluminium with effective thermal management, sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of 11000 lumens and maximum system wattage of 100 Watt. The fixture shall have a CRI of minimum 70; SDCM<5; Color temperature should be of 5700K. The fixture shall be designed for a system life of 50,000 hours @L70B50. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK07. The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=4KV, PF >0.9 and THD<10%. The fixture should comply with the parameters as per IS10322. The LED driver should have Fixed output, High Cut @325V , capable to withstand 440V for 8 Hrs and auto restart feature. Driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.Suitable arrangement to be made for fixing of light in existing bracket. The Luminaires shall be aesthetically appealing and should have no extremal visible fins. LED's, driver and fixture should be BIS approved and same make, complete making connections with street light terminal box with and including PVC insulated & sheathed single core cable of size 1.5 Sqmm 3 run for phase, earth,neutral complete all as spd and directed. Make of LED light fitting:- Philips Cat No : BVP192 LED110 CW HO NB FG GR PSU or equivelent in Osram/ Bajaj/ Wipro
Supply and fix in replacement surge protection devices having capacity 10 KV ISI Approved company made as Crompton, Wipro, Halonix, C.G. , HPL etc. suitable for LED fittings upto 150 watt any type and make complete all as specified and directed
Supply and fix in replacement electronic driver ISI approved company made as crompton/wipro/Halonix/C.G/HPL/Polycab suitable for LED fittings 45 watts any type and make complete all as specified and directed .
Supply and fix in replacement electronic driver ISI approved company made as crompton/wipro/Halonix/ C.G./HPL/Polycab suitable for LED fittings 60 watts any type and make all as specified and directed
Material and labour for GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.
Material and labour for GI tubing light grade 40mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.
S&F in replacement post top light fitting with B-22 holder incl LED bulb 9 to15Watt incl necessary arrangement for fixing on existing pipe complete all as specified and directed .
Removing all connections from Security Lights Panel any Capacity or type for repair & servicing. Seggregating serviceable and unsv items, Cleaning properly all serviceable parts by removing dust, carbon deposits etc, replacing unsv MCB,contactor,time switch of exisitng size/make, replacing old unsv bus bar from junction boxes, replacing unsv thimbles if any of connections and refixing the serviceable items and making electric connections incl fixing panel doors with nuts, bolts and washers and testing complete all as required at site or directed.
Removing all connections from high mast light Panel any Capacity or type for carrying out minor repair or servicing. Cleaning properly all serviceable parts by removing dust, carbon deposits etc, replacing unsv MCB,contactor,time switch of exisitng size/make, replacing unsv thimbles if any of connections and refixing the serviceable items and making electric connections incl fixing panel doors with nuts, bolts and washers and testing complete all as required at site or directed . Note: Replacing unsv items upto Rs 200 deemed to be incl in the rate quoted by the contractor.
KULBHUSHAN AGGARWAL
M/s USHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .