Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Mar 2021, 6:00 pmClosed
GE (AF) TECH AREA AGRA
GE (AF) TECH AREA AGRA
REPAIR AND MAINT OF SECURITY LIGHT WIRING AND CONNECTED ACCESSORIES ON HANGAR INCLUDING ANNEXES AND BLDGS IN TECH AREA UNDER GE (AF) TECH AREA AGRA
2021_MES_421771_1
8200-1319/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) TECH AREA AGRA
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA AGRA
₹90,000
Yes
28 Apr 2021
13 Feb 2021
6 Mar 2021
13 Feb 2021
4 Mar 2021
20 Feb 2021
13 Feb 2021 - 16 Feb 2021
Amount
Taking down carefully Aluminium/copper point wiring (Light/ Fan/Socket or power) complete including fitting fixture such as switches, sockets, ceiling rose, brackets, holders, bulk head fitting etc and making good disturbed surface of wall/ceiling etc. complete all as specified and directed.
Taking down security light any type by disconnecting the electric supply complete all as specified and directed.
Taking down main switch/MCB DB/AC enclosure/Three phase enclosure by disconnecting the electric supply complete all as specified and directed.
Taking down old U/S sub main wiring aluminium/copper including batten/conduit and making good disturbed surface to match the existing surface complete all as specified and directed.
M&L for point wiring for security light complete with multi stranded copper conductor 1.5 Sq mm size (Nominal area) PVC insulated unsheathed cable FRLS in and including PVC conduit on surface ISI marked not less than 20 mm dia complete with all accessories complete all as specified and directed.
M&L for point wiring for hanger light/security light complete with multi stranded copper conductor 2.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLS in and including surface PVC conduit on surface ISI marked not less than 20mm dia with including 2.5 sqmm multi stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories fo two hanger light controlled by one MCB SP all as specified and directed. Note for items No 5 & 6 :- (i) Average Length of Point Wiring for Hangar Lights is Apporximately 30 RM (ii) The Working Heigth For Hangars Lights is Appx 21 mtrs above Ground Level. Cost of Scafolding and other T&P shell Deemed to be included in the unit rate quoted. No extra Charge shell be paid for this propose.
S&F in repair LED street light fitting made up of pressure die cast aluminium housing with toughned glass and high power LED with IP 66 with 10 KV SPD 45 watt LED bulb complete all as specified and directed. Make Crompton cat part LSTS-45-CDL-M or Havells cat part ENDURAPEARLNEOSL40WLED757PASYTOPC or equivalent in specified makes as approved by GE.
S&F in repair LED street light fitting made up of pressure die cast aluminium housing with toughned glass and high power LED with IP 66 with 10 KV SPD 60 watt LED bulb complete all as specified and directed. Make Crompton cat part LSTP-60-CDL-M or Havells cat part ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent in specified makes as approved by GE.
S&F in repair LED street light fitting made up of pressure die cast aluminium housing with toughned glass and high power LED with IP 66 with 10 KV SPD 100 watt LED complete all as specified and directed. Make Crompton cat part LSTP-100-CDL-M or Havells cat part ENDURAPEARLMAGNUMSL100WLED757PASYTOTGAST or equivalent in specified makes as approved by GE.
S&F in repair 120 watt LED flood light fitting suitable fixing on hanger and building including all fixing arrangement high grade aluminium pressure die cast and toughened glass high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of IP 66 complete all as specified and directed . Make Crompton ordering code LFLN-120-CDL/60-M or Havells cat part JETAIRISSFLS120WLED757APWBLTG or equivalent in specified makes as approved by GE.
S&F in repair 150 watt LED flood light fitting suitable fixing on hanger and building including all fixing arrangement high grade aluminium pressure die cast and toughened glass high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of IP 66 complete all as specified and directed with ordering code- LFLN-150-CDL/60-M make crompton or make havells ordering code JETAIRISSFLS150WLED757PSYMLTG or equivalent in specified makes as approved by GE.
S&F in repair 200 watt LED flood light fitting suitable fixing on hanger and building including all fixing arrangement high grade aluminium pressure die cast and toughened glass high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of IP 66 complete all as specified and directed with make Crompton ordering code LFLN-200-CDL/60-M or havells Ordering code JETAVALOURFL200WLED757PINTWBLTG or equivalent in specified makes as approved by GE.
M&L for sub main wiring drawn in and including multi stranded copper conductor 2.5 Sqmm size (Nominal area) 2 Nos PVC insulated unsheathed cable FRLS in and including PVC conduit on surface ISI marked not less than 20mm diawith fitting and fixture complete and 2.5 sqmm stranded copper conductor, 1 No PVC insulated cable of green colour as earth continuity connected to common earth dolly complete all as specified and directed
Supply, laying, testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire , armoured heavy duty electric under ground LT cable 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core and laid in trenches/passing through pipe/ducts or on pole with Fixing arrangemant complete all as specified and directed.
S&F MCCB TPN DB,4 way Vertical type,440V,3 phase with rated busbar 100 Amps, double door type suitable for MCCB as a incomer and MCBs as out going, IP 54 and IP43-IK 09 with metal door double door type, grouted in walls with with Fixing arrangemant complete all as specified and directed. Make-Legrand cat No-5077 50 or equivalent in L&T / Schneider in specified makes as approved by GE.
M&L for MCB DB of sheet metal enclosure double door acrylic door type, single pole and neutral 8 way with 200 Amp rated bus bar 240V and with Fixing arrangemant complete all as specified and directed.
M&L for MCB DB of sheet metal enclosure double door acrylic door type, single pole and neutral 4way with 200 Amp rated bus bar 240V and with Fixing arrangemant complete all as specified and directed.
S & F MCB SP 6 to 32 Amps, 240V 'C' Series 10 KA all as specified and directed.
S & F MCB SPN 40 to 63 Amp 240 Volts 'C' series 10 KA all as specified and directed.
S & Fixing MCCB DPX 160 thermal magnetic of 63 Amps 4 pole 16 KA, 415 Volts 50 Hz complete including connecting all incoming and outgoing connection by means of suitable size of lugs/thimbles all as specified and directed Make : Legrand Cat No 4207 13 or equivalent in specified makes as approved by GE.
S&F security light bracket made up of GI pipe 40mm dia light grade for mounting, bracket bent to safe 1.5 Meter with 1 coat of zinc oxide primer and 2 coat of aluminium paint including suitable FI clamp and nut bolts complete all as specified and directed.
S&F for sub main wiring with PVC insulated sheathed 2x4 sqmm and 1x4sqmm single core FRLS cable multi stranded copper stranded copper conductor 1100 volt grade be use as continuous earth connected to earth down and incl into surface PVC condute not less than 25mm dia with all accessories complete all as specified and directed.
S&F for sub main wiring with PVC insulated sheathed 2x6 sqmm and 1x6sqmm single core FRLS cable multi stranded copper conductor 1100 volt grade be use as continuous earth connected to earth down and incl into csurface PVC condute not less than 25mm dia all accessories complete all as specified and directed.
M&L for bracing,supports,clamps and back plate fabricated from structural steel, section including nut,bolts,washers,welding, bending cold or hot, drilling holes for bolts, in any shapes or size as indicated or directed for fixing switch board, DBs and for mounting of security light bracket bent etc all as specified and directed. Note : Contractor should coat the prices as certain light are required to be changed/ repair at hangar upto the hight 21 mtr hangar wall and other hangar contractor has to arrange own T&P for repair and replacement the same for serviceable.
Unnati Engineers
Balaji Associate
UNIQUE INDIA CONSTRUCTIONS
S.D.TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .