| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹43.6 L+₹7.8 L (21.8%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹44.5 L
EMD Value
₹88,900
Closing Date
24 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engr
HQ 134 Wks Engrs PIN-914134 C/o 56 APO
REPAIR/ MAINT OF 11 KV HT ELECT NETWORKS INCLUDINGS CONNECTED ITEMS SUCH AS TRANSFORMERS, VCBs, CT/PT, GOD, DO FUSES, AVR, CABLES ETC AT OAF UNDER GE 970 EWS
2022_MES_554025_1
134 WE-46(T)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Srinagar
9 documents required · 9 mandatory
₹500
GE 970 EWS
₹88,900
Yes
6 Dec 2022
23 Sept 2022
26 Oct 2022
24 Sept 2022
24 Oct 2022
9 Oct 2022
24 Sept 2022 - 1 Oct 2022
Amount
Excavation in trenches not exc 1.5mtr wide and not exc 1.5mtr in depth and getting out in any type of soil for taking or laying of cables, pipes, erection of pole etc, complete all as specified and directed.
Excavation in trenches exc 1.5mtr wide and exc 1.5mtr in depth and getting out in any type of soil for taking or laying of cables, pipes, erection of pole etc, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing excavated soil to a distance not exc 50 mtr and deposting where directed at a level not exc 1.5m above the starting point, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick after laying the cable, and laying in duct of any thickness of sand, complete all as specified and directed. Note :- Punned thickness of sand provided for cable protection shall be measured & paid.
M&L for brick well burnt locally available sub class 'B' brick over sand cushioings to cable in per trenches keeping width of brick parallel to the length of cable, complete all as specified and directed.
M&L for GI tubing light grade 80mm bore with all fittings, laid in trench or fixed on wall, along with pole for protection of cable including taking up or down old existing GI tubing, complete all as specified and directed by Engr-in-Charge.
All as per Ser item No 7.00 here-in-above but 100 mm bore.
M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in foundation, mass concrete etc including necessary form work, complete all as specified and directed.
M&L for PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregates) as in foundation, coping etc including necessary form work, complete all as specified and directed.
M&L for coarse aggregates (broken stone or boulders) of size 40-80mm, laid or filling in sub station yard, complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in stay filling, coping etc, including necessary form work, complete all specified and directed.
Dismantling old and unserviceable prestressed concrete poles of any type including breaking cement concrete complete and supply and erection new steel tubular swaged pole with cast iron base plate finial tapper plug, bolts, nuts and screws and type 410-SP-55 (11 mtr long) in truly vertical position 1.5 mtr length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30cm width (black and yellow alternatively) and painting complete with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts, complete all as specified and directed by Engr-in-Charge. Note :- Earth work and PCC shall be measured and paid seperately under respective items of BOQ.
Dismantling existing old unserviceable ACSR conductor of any size and any description and S&F new ACSR conductor including stringing through existing RCC/ steel poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc. complete of different sizes, complete all as specified and directed. Note :- Rates for new aluminium tape / copper binding wire shall be deemed included in quoted rates.
S&F mild steel cross arms channel, bracing, support, clamps etc, fabricated from structured steel, sections including nuts, bolts, washers etc and cutting to required length beat to any shape, drilling holes, fixed on poles or jointed by means of elect welding complete including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer after preparation of surfaces including taking down / dismantling the old items, complete all as specified and directed.
Dismantling of existing old unserviceable earth wire and gradle guard of any size from any position and S&F new GI wire 4mm dia (8 SWG) on poles to continuous earth wire and cradle guard etc, complete all as specified and directed.
M&L for stay assembly complete with 20mm dia stay rod with accessories, shown in electric plate No. 01 including stay clamps and including dismantling old unserviceable stay assy, complete all as specified and directed. Note :- Loop insulator, stay wire, excavation and cement concrete shall be measured and paid seperately under respective items of BOQ.
S&F in replacement galvanised stay wire of size 7/4mm, complete all as specified and directed.
S&F in replacement loop insulator, vitreous porcelian white or brown of size 90mm X 140mm, clearance hole 25.5mm, complete all as specified and directed.
S&F in replacement disc type porcelain vitreous brown or white insulator, suitable for 11 KV HT working pressure, size 145mm height and 255mm dia including one galvanised mild steel spindle, two galvanised iron washer and one GI nut, complete all as specified and directed.
S&F in replacement pin type porcelain vitreous brown of white insulator, suitable for 11 KV HT of working pressure, size 150mm height and 150mm dia including one galvanised mild steel spindle, two galvanished iron washer and one GI nut, complete all as specified and directed.
S&F in replacement pin type porcelain vitreous brown of white insulator, suitable for 11 KV HT of working pressure, size 100mm height and 65mm dia including one galvanised mild steel spindle, two galvanished iron washer and one GI nut, complete all as specified and directed.
S&F in replacement shackle type porcelain vitreous brown or white insulator of size 115mm dia and 100mm height including GI strap of size of 31x5mm, insulator bolt of 14mm dia, nuts and washers for working pressure 1100 Volts, complete all as specified and directed.
S&F in repairs incl testing of swing out explusion fuse isolated assembly with fuse carrier out door type 11 KV supply 50 Amp (DO Fuse) incl mounting bracket & post insualtor, complete all as specified and directed.
S&F in repairs transmission class type drop out fuses 11000 volts ratings 25-50 amps, outdoor type, complete all as specified and directed.
Taking down triple pole mechanism complete with DO Fuse unit from the site and Supply and Install new DO fuse unit triple pole, mechanically operated, mounted on insulator and steel frame with opertaing mechanism worked from ground level with GI pipe medium grade, for current rating upto 200 Amps and air break (switch) insulator suitable for HT 11 KV, outdoor type 50 Amps (DO Fuse), complete all as specified and directed. Make :- Atlas / GEC / Pactil
S&F in replacement lightning arrester, expulsion type complete with all fittings transmission class, discharge capacity 65 kilo Amps, suitable for 11 KV, complete all as specified and directed.
S&F in replacement cable jointing kit for 11 KV grade cable, Outdoor termination, shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed. Make :- 3M / Birla / Denson
All as per Ser item No 28.00 here-in-above but 3 core 120 to 185 Sqmm size.
S&F in replacement cable jointing kit for 11 KV grade cable, Indoor termination, heat shrink type joint, complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed. Make :- 3M / Birla / Denson
All as per Ser item No 30.00 here-in-above but 3 core 120 to 185 Sqmm size.
S&F in replacement cable jointing kit for 11 KV grade cable, Straight through joint, heat shrink type joint, complete with jointing material and accessories, suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed. Make :- 3M / Birla / Denson
All as per Ser item No 32.00 here-in-above but 3 core 120 to 185 Sqmm size.
M&L for painting of HT/LT panel of any description with one coat of synthetic enamnel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun etc complete all as specified and directed.
Supply, laying, testing and commissioning XLPE PVC insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed) of size 3 Core 95 Sqmm, laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas, complete all as specified and directed.
All as per Srl item No. 35.00 here-in-above but cable size 3 Core 120 Sqmm.
S&F in repair / replacement of plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cut to required shape and size for cable duct or any other description, confirming to Fe- 410-W (Gde-E-250) quality 'A', complete all as specified and directed.
S&F in repair post insulator suitable for 11 KV HT working pressure in GOD /DO arrangements of any description, complete all as specified and directed.
Repairing/serviceing the Air break isolating switch HT 11 KV 200/400 Amps by repacing the defective major spares including provn of minor bolts nuts etc, complete all as specified and directed. Note :- Major spare will be measured & paid seperately under relevent item of Sch 'A' item No 40.1 to 40.5 here-in-below.
S&F in repair 11 KV Airbreak switch spares, complete all as specified and directed:-
Male contact/moving contact blade
Female contact/fix contact Jaw
MS jumper carrier
Back connector plate
Petroleum Jelly
Repairing/ servicing the Air break isolating switch HT 33 KV 200/400 Amps by replacing the defective major spares includings provn of minor bolts nuts etc, complete all as specified and directed. Note :- Major spare will be measured & paid seperately under relevent item of Sch 'A' item No 42.1 to 42.5 here-in-below.
S&F in repair 33 KV Airbreak switch spares, complete all as specified and directed:-
Male contact/moving contact blade
Female contact/fix contact Jaw
Rotating contactor pipe 200A/400 A
MS jumper carrier
Back connector plate
Re-stringing only existing HT 11/33 KV / LT OH line / Jumpers including dismantling of existing old binding wire for tightening, complete all as specified and directed. Notes :- (a) Re-stringing of each wire shall be measured as in RM. (b) New binding wire shall be measured and paid separately under respective item of BOQ.
S&F in replacement for PVC insulated armoured heavy duty single strand solid copper conductor electric cable with 1100 volt grade with cross section area 12 Core 2.5 Sqmm, complete all as specifed and directed.
S&F in replecement drop out (DO) fuse unit, expulsion type, outdoor three pole 200 Amps suitable for HT 11 KV, comprising of 6 Nos post insulators, GI steel base mounting frame, GI nut bolts etc. with 30A, HT barrel type fuse, complete all as specified and directed.
Supplying, fixing in repair including testing and commissionin of gang operated air breaker switch horizontal/vertical type mounting complete, double break and operation rod of suitable length 400 Amp capacity with 09 Nos post insulators and suitable for 33 KV HT supply, complete all as specified and directed.
S&F in repairs lighting arrestor Zinc oxide gap less type, station class suitable for 33 KV/10 KA complete with all fittings all as specified and directed.
S&F in repair single post insulator, 33 KV with mounting sprindle etc, complete all as specified and directed.
S&F in repair Pin insulator, 33 KV with mounting, spindle etc, complete all as specified and directed.
S&F in repair disc insulator, 33 KV with hardware fittings etc, complete all as specified and directed.
M&L for preparation of old painted surfaces, removing dust and other deposited materials on HT tubular pole of 11 Mtr long by scraping and applying one coat of aluminium paint paint up to 1 Mtr from bottom and painting the rest of the pole including cross arms, clamps etc, complete all as specified and directed. Note for 51 & 52: This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in the structures and each job will be measured and paid.
All as per Srl item No. 51.00 here-in-above but for 4 pole structure.
M&L for preparation of old painted surfaces of HT 33/11 KV MRS yard (Old system & New map system) at Old Air Field consisting of steel poles/ ISMBs, cross arms, GOD pipe, clamps etc. having of any description and applying one coat of :- Note :- (a) This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item. (b) This painting work will be carried out during Holiday only to avoid elect shut down.
M&L for removing vegitation, grass scrubs, creepers and bushes growing in sub station yard, around the poles/stays etc, alongwith fancing by mannually/ mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Notes :- (a) Unit are quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleanig will be measured and paid separately.
S&F in repairs including testing of metering & protection current transformer Oil filled out door type of 33 KV capacity ratio 100-50/5 or 200-100/5 class=5P, 10/1 15 VA including dismantling old existing CT complete all as specified and directed. Note :- Calibration & testing record for the sane should be submitted by the contractor to Engr-in-Charge.
S&F in repairs cable and box heat shrinkable type outdoor, suitable for XLPE cable 3 core, 185 Sqmm, 33 KV HT supply, complete all as spefied and directed.
Dismantling old and burnt out PT unit 11000/110 volts volts draw out type expoxy resin cast type taking out contact with lead and bushing from the bus bar and PT, replacing by new one of same model suitable for 11 KV VCB incl testing on completion complete all as specified and directed.
M&L for Cutting and trimming of tree branches from any height and type of trees in route of HT over head line or near to the HT over head line or obstructing illumination of street light as per the direction of Engr-in-charge and cleaning of site. Notes : (a) The tree branches shall be 2 Mtr away from the outer conductor of OH lines after cutting. (b) Any damage cause due to contractor's labour will be rectified by the contractor without any extra cost to Govt. (c) T&P such as ladder, rope, cutter, Axes and other required tools shall be provided by the contractor.
S&F in replacement insulating rubber mat ISI marked 1mtr x 2mtr x 19mm suitable for 11 KV at 33 KV MRS OAF, complete all as specified and directed.
M&L for replacement of temperature guage size for power transformer /AVR of any capacity, complete all as specified and directed.
M&L for PVC sleeves suitable for LT/HT ACSR conductor/ Jumper in any type in RYB colours superior quality inserted over the existing ACSR complete all as specified and directed.
M&L for preparation of old surface, cleaning of the steel pole (HT), 11 Mtr long pole structures above the ground level including coping area and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and it's connected parts, complete all as specified and derected.
S&F in repair bolted type LM 6 alloy aluminium rigid stud terminal connector of type universal connector suitable for 33/11 KV type ACSR conductor/busbar complete all as specified and directed.
S&F in repair bolted type LM 6 alloy aluminium rigid pad type terminal connector for pad to connector suitable for 33/11 KV type ACSR conductor complete all as specified and directed.
S&F in repair bolted type LM 6 alloy aluminium rigid parallel connector conductor to conductor suitable for 33/11 KV type ACSR conductor complete all as specified and directed.
Taking out the exisitng HT AVR unit 11000 volts grade of Make 'Yule Brentford' carefully by dismantling all incoming & outgoing elect/mechanical connections, lifting and transport to reputed work shop by means of using suitable tools & plants, opening the body of AVR units find out the defects and servicing, repair/removing including relplacing the defective spare parts and re-assembling, complete all as specified and directed by Engineer-in-Charge. The job involves the following :- (a) Dehydration of oil / new winding will be measured and paid under relevent item of BOQ. (b) Dismantling & taking down carefully from plant room by disconnecting all electrical / mechanical connection from HT and LT side including transporting to work shop. (c) Opening the body of the AVR/buck booster units complete, drain out the oil, lift the cover and coil assembly, checking the serviceability state of spares such as moving carbon roller, windings, insulating oil, LT/HT elect connections, HT/LT bushings, HT/LT brass terminals, Tig & Tag connectors, chain rack, limit switch, bearings, couplings, motor, Microprocessor based PCB card, CT/PT assy, Aux / Reverible contactors, Winding/Oil temp/Buchloz relays assy, earthing connections, copper strip, etc and repair / replace the same of existing model/make and making fully serviceable state of AVR/Buck booster assy at site incl testing as per OEM specifications complete all as directed, (d) Cleaning the core laminations assembly by oil complete, removing the carbon sediments / dust in the coil and core gently without making any damage to coil and core. (e) Re-assembling all dismantled parts including provision of new gasket, nut, bolts, refilling with transformer oil and transporting back to original location including electric/mechanical connection testing and commissioning complete.
S&F in repairs moving carbon rollers of existing size and make suitable for 2000 KVA AVR unit complete all as specified and directed.
S&F in repairs Tie & Tac brass connector suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs chain rack (double) incl bearing, complete all as specified and directed.
S&F in repairs limit switch suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs SS coupling suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs chain assy suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs synchronous motor suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs PCB card suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs PT unit 11000/110 volts suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs Reversible contactor 3 pole 800 Amps suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs winding terperature relay complete suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs Oil termperature relay complete suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs Buchloz relay asy complete suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs copper strip of any size suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs connector strip 16 way/24 way suitable for 2000KVA AVR unit complete all as specified and directed.
S&F in repairs Aux contactor suitable for 2000KVA AVR unit complete all as specified and directed.
Taking down carefully the existing 11KV/433 Volt distribution transformer of capacity 100 KVA to 600 KVA by disconnecting HT overhead connection/underground cables and earth strips etc from any substation/location using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully, reloading the transformer after repairs and testing of transformer, transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed by Engr-in-Charge. Note :- All the T&P required for disconnection, connection, loading and unloading including necessay petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted.
M&L for repair toTransformer step down 11KV / 0.433 KV of any type, of capacity 100 KVA to 250 KVA, after dismantling the transformer body carefully, opening the top cover of transformer for inspection/repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, renewal/replacement of unsv rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside by weather proof type using spray gun, marking of MES/SM Number etc, replacement of conservator tank glass, reinstalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, meggering the LT and HT side of the transformer and testing (testing repaort shall be done in presence of Engr-in-Charge and record thereof shall be kept duly signed and approved by GE), complete all as specified and directed. Note :- Winding wire for making of coils and LT/HT bushes will be measured & paid seperately under respective item of BOQ.
Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation/ leakage/ losses due to dehydration in HT 33 KV transformer / HT 11 KV AVR / distribution transformer 100 to 600 KVA or for replacement complete including draining of old unservicable transformer oil, complete all as specified and directed.
M&L for conducting oil filtration by stream line / vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer including routine testing after filtration for any capacity of transformers/AVR/CT/PT units, complete all as specified and directed. Note :- The contractor shall be change the filter assy before starting the filtration of transformer / AVR of capacity 600 KVA and more capacities in presence of Engineer-in-Charge.
S&F in replacement of brass terminal rod with nuts, bolts washers & bushings, suitable for HT side of the transformer of any make and capacity from 100KVA to 300 KVA, complete all as specified and directed.
All as per Ser item No 87.00 above but LT side.
S&F in replacement of brass terminal rod with nuts, bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 315 KVA to 600 KVA, complete all as specified and directed.
All as per Ser item No 89.00 above but LT side.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100 KVA to 300 KVA transformer, complete all as specified and directed.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA to 600 KVA transformer, complete all as specified and directed.
M&L for painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc, paint free after painting including writing the MES/SM Number with white enamelled paint, complete all as directed for capacity of transformer 100 KVA to 600 KVA (Indoor/outdoor type), complete all as specified and directed.
All as per Ser item No 93.00 above but for capacity of transformer 1000 KVA to 2000 KVA (Indoor/outdoor type).
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 1000 KVA to 2000 KVA transformer / AVR units, complete all as specified and directed.
M&L for earthing complete with GI earth plate of size 60cmx60cmx6mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip of size 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, 40mm dia light grade protection pipe and salt etc. and connected to earthing test point including dismantling of old unserviceable earthing and takingn out material, complete all as specified, directed and testing after completion.
S&F in replacement off load tap changer for distribution transformer of any make and capacity from 200-600 KVA, complete all as specified and directed.
M&L for super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding the HT/LT transformer / HT AVR of any capacity and any make, complete all as specified and directed.
M&L for super enamelled aluminium conductor wire of suitable gauge and size as per requirement for rewinding the LT transformer/AVR of any capacity and any make, complete all as specified and directed.
S&F in replacement of brass terminal rod with nuts, bolts washers & bushings, suitable for 33KV side of power transformer of any make and capacity from 1000KVA to 2000 KVA, complete all as specified and directed.
S&F in replacement of brass terminal rod with nuts, bolts washers & bushings, suitable for 11KV side of power transformer of any make and capacity from 1000KVA to 2000 KVA, complete all as specified and directed.
S&F in replacement of bush type insulator white/brown/green, working pressure 11000Volts HT side, complete all as specified and directed.
S&F in replacement of bush type insulator white/brown/green, working pressure 433 Volts LT side, complete all as specified and directed.
M&L for servicing and repairing of OLTC (ON load Tap changer) for 33 KV Transformer by disconnecting and dismantling all burnt out cables / fuses/ relays / contactors, toggle switch/knobs /indicators/reading units and other accessories repairs / replace the unserviceable items and making the OLTC serviceable condition and connecting back to its original position, complete all as specified and directed.
M&L for servicing of 33 KV VCB/ 11KV VCB / bus coupler by dismantling, cleaning, greasing the complete VCB with attached relays bus bar etc. insulation testing, setting the contact gap by measuring as required re-assembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning, complete all as specified and directed. Note :- New spares parts shall be measured and paid separately under respective items of BOQ.
M&L for carrying out primary & secondary injection test of 11 KV indoor / outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning including submitting the test report, complete all as specified and directed. Note :- PIT/SIT for VCB will be carried out in 6 months intervals and each primary & secondary injection test will be measured and paid and considered as one unit.
Supply only the following spares for outdoor VCB 33 KV 800 A 750 MVA fault level 36V-26/2000 & VCB 11 KV 400 A 25 KA 250MVA as approved by GE against Ser item No 105 above :-
Closing coil 24/30V DC.
Tripping coil 24/30V DC.
Antipumping device 24/30V DC.
33 KV porcelain bushing for VCB top.
33 KV porcelain bushing for VCB bottom.
Connector strip 16 way.
Earth fault and over current relay, L&T Model No. MC61A 24-110V.
Digital type power factor indicator meter.
Digital type Voltmeter / Ammeter, 96mm x 96mm size.
LED type indicator lamp assembly.
Vacuum interrupter for indoor VCB.
Spout incoming side.
Spout outgoing side.
Epoxy insulators bushings for incoming / out going cables / bus bar supports as per existng size of VCBs.
Insulated copper bus bar of existing size and thickness for VCBs.
Gear system assy complete with handle for charging / discharging of VCBs.
Spring charging motor for VCBs.
Supply only DO fuse elements 11 KV grade having fire resistant tube and soldred joint with ferrule, 24.5" long crimped joint stranded silver/tin coated wire of 2.5 to 25 Amp capacity.
All as per item ser No 1108 here-in-before but 30 Amp to 40 Amp capacity.
All as per item ser No 1108 here-in-before but 50 Amp capacity.
Supply only DO fuse elements 33 KV grade having fire resistant tube and soldred joint with ferrule, 33" long crimped joint stranded silver/tin coated wire of 2.5 to 25 Amp capacity.
All as per item ser No 111 here-in-before but 30 Amp to 50 Amp capacity.
M/S Noor Mohammad Shalla
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .