| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹276.5 CrAccepted-AOC 4B TOWN SQUARE CHINAR PARK RAJARHAT KOLKATA 700 136 | ₹276.5 Cr Quoted ₹288 Cr | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical NON RESPOSNIVE |
| 3 | Rejected-Technical | - | - | Rejected-Technical NON RESPONSIVE |
| Sl No | Description | Qty | Unit | Tribeni Constructions ltd L1 |
|---|---|---|---|---|
| 1.00 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. | 3,239.12 | Cum | 500 ₹16.2 L |
| 2.00 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. | 25 | Cum | 1,000 ₹25,000 |
| 3.00 | Dismantling RCC work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. | 1,023.93 | Cum | 2,000 ₹20.5 L |
| 4.00 | Taking down old door and window shutter including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. | 4,515 | Each | 50 ₹2.3 L |
| 5.00 | Removing dry or oil bound distemper, water proofing cement paint, all paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | 2,37,849.52 | Sqm | 20 ₹47.6 L |
| 6.00 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm | 42,742 | Sqm | 50 ₹21.4 L |
| 7.00 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | 4,000 | Sqm | 50 ₹2 L |
| 8.00 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed
by Engineer-in-charge. | 8,573 | Sqm | 50 ₹4.3 L |
| 9.00 | Demolishing mud phaska in terracing and disposal of material within 50 metres lead. | 1,028.76 | Cum | 750 ₹7.7 L |
| 10.00 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. | 3,540 | Nos | 100 ₹3.5 L |
Tender Value
Refer Docs
EMD Value
₹2.8 Cr
Closing Date
20 Jun 2025, 5:00 pmClosed
Nodal Officer
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Beside Jharkhand Mantralaya, Dhurwa, Ranchi-834004.
Renovation and Augmentation Work of Old IPD Block at RIMS, Ranchi
2025_JSBCC_101321_1
JSBCCL/14/2025-26
Open Tender
Civil Works - Buildings
730 days
Ranchi
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹2.8 Cr
JSBCCL
20 Jan 2026
23 May 2025
23 Jun 2025
23 May 2025
20 Jun 2025
23 May 2025
30 May 2025
Amount
Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Dismantling RCC work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Taking down old door and window shutter including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Removing dry or oil bound distemper, water proofing cement paint, all paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
Demolishing mud phaska in terracing and disposal of material within 50 metres lead.
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Dismantling uPVC. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :
75 to 80 mm dia pipe internal
100 mm dia pipe
150 mm dia pipe
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.
Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge.
Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete.
Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge.For door/ window/ clerestory window
Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener.
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.
EARTH WORK
Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
CONCRETE WORK
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying in position cement concrete of specified grade Excluding the cost of centering and shuttering - All work upto plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded stone aggregate 20 mm nominal size
REINFORCED CEMENT CONCRETE WORK
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing and fixing in position stainless steel grade 304 plate-1.0 mm thick as per design for expansion joints 200 mm wide
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063) floor 100mm
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).Wall joint of 100 mm gap
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre- engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063).Roof joint of 100 mm gap
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, cement content as per approved design mix, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.
All works upto plinth level
All works Above plinth level
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.
Centering and shuttering including strutting, propping etc. and removal of form for: lintels, beams, plinth beams. girders. bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts.
Centering and shuttering including strutting, propping etc. and removal of form for: Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.
Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls. Under 20 cm wide
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. includIng cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landings, beams and balconies (Plan area to be measured).
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 50mm thick
Providing Tor steel reinforcement of 8mm. dia.TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 10mm,28/32mm dia. TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 12/16mm. & 20/25mm. dia. TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Extra for filling grooves with polysulphide 5mm wide, 10mm deep.
BRICK WORK
Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforced designation 100A brick work with flyash lime brick (FLAG) in (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary
Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of Ell.
WOOD WORK
Supplying fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and laxes all conrplete as pe building specrfication and direction of E/l.
Supplying fitting and fixing 35mm thick solid core type decorative double leaf flush door sltutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and laxes all conrplete as pe building specrfication and direction of E/l.
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs,
floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.
66mm overall thickness partition using 8mm thick double skin multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process (High pressure steam cured) as per IS : 14862 with suitable fibre cement screws
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer- in-charge Profile C Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5.50 mm thickness
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : Rectangular or square.
Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 35 mm thick shutters- Second class teak wood with ISI marked M.S. pressed butt hinges bright finished of required size
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality 1.0 mm thick.
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strengh congorming to is;4454-part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25mm M.S. laths with 1.25 mm thick top cover.
Providing and fixing ball bearing for rolling shutters.
Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-charge.(area of grill to be measured).
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete:
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete:
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade wiIh necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete Twin rubber stopper
Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete 255 X 19 mm
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Polyester Powder coated minimum thickness 50 micron aluminium tubular handle bar.
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Polyester Powder coated minimum thickness 50 micron aluminium.
Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge Polyester Powder coated minimum thickness 50 micron aluminium
STEEL WORK
Supplying, fitting and fixing 16mm dia M.S. Gratings (inclusive) of one 25X 6mm M.S. Flate for height exceeding 1M . With necessary holes) to windows making holes in choukhats, cutting bars to size, fittingand fixing the same in position including straightening the bars all complete as per building specification and direction of E/I.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge.Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
FLOORING WORK
Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing and laying 25mm thick. Kotah stone slab flooring of approved size, texture and colour over 19mm thick base of lime mortar (1:1:1) (lime putty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royality all complete as per building specification and direction of E/I. (iv) 600 x 600 mm size
Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Medium shade pigment using 50% white cement 50% Grey cement
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry@ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
providing and laying, vitrified step/dado tiles in with water absorption less than 0.08% and conforming to lS 15622/ of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 1200x300 mm X15MM
providing and laying, Doublecharge vitrified floor tiles in different sizes (thickness to be specified by lhe manufacturer) with water absorption less than 0.08% and conforming to lS 15622/ISO 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 600x600 mm
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills. facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, induding rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels.Granite of any colour and shade.Area of slab upto 0.50 sqm
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills. facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, induding rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm.
Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. 8.mm thick Granite of any colour and shade
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing & Fixing flexible Conductive PVC sheet flooring of Armstrong/ Forbo/ Polyflor having a total thickness of 2mm and weight of 3kg/m².Colors and pattern detail shall be dispersed throughout the thickness of the wear layer. It shall conform to Group P of Wear Resistance as per EN 649, Flammability of class Bfl-s1 as per EN 13501-1, Slip resistance as per DIN 51130 group of R9 , having REACH Registration No, 1907/2006 contains no substance mentioned in SVHC list. Impact sound reduction of 3 dB as per ISO 140-8, Residual indentation of 0.05 mm as per EN 433, Color fastness rating ≥6 as per ISO 105-B02, Vertical resistance(R1) less than 1 x 10⁶- 1x 10⁸Ω as per EN 1081, and surface resistance less than 1 x 10⁶- 1x 10⁸ Electrical insulation to ground greater than 50 kΩ as per VDE 0100, Static electrical charge of ≤2.0kV as per EN 1815, Thermal resistance of 0.04m²K/W as per EN 12667, Thermal conductivity of 0.25 W/mK. Equivalent to Armstrong PASTELL. Installation:It is important to ensure the sub floor on which the sheet is being laid is smooth, flat & hard & free from moisture, grease, etc. In case of uneven sub floor the same should be leveled by self leveling compound. The moisture level present in the subfloor should be less than 8% before installation of the floor. The sheet should be laid using adhesive recommended by company.Each row of tiles/strip of floor covering must be linked crosswise with a continuous copper strip. Individual rows/strips must be at least 3 m² in size and linked to the rest of the area with a copper tape. In rooms of up to 40 m², connection points for equipotential bonding should be provided in at least one point in the room. Approv make- Armstrong, Polyflor, Forbo
Supply and installation of PVC sheet flooring 2 metre wide and overall thickness of 2mm of Armstrong/ Forbo/ Polyflor. The product should be homogeneous and single layered. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVCwith DIAMOND 10 technology, Plasticizers without DOP, Urethane, color pigments and filler calendered to form a sheet. Product shall conform to group "T" wear resistance as per EN 649, Flammability resistance of class Bfl-s1 as per EN13501-1, Dynamic coefficient of friction of class DS as per EN 13893, Impact sound reduction of 3dB as per ISO 10140, Slip Resistance of class R9 as per DIN 51130, Color fastness rating of ≥6 as per ISO 105-B02, total weight being 3.3 kg/m2 as per EN430. The product shall be suitable for applications in class 23/34/43 areas as per EN685. Product shall exhibit antistatic behaviour, resistance to bacteria,resistance to chemical, resistance to staining,suitability to castor chair. Equivalent to Armstrong Simpurity Installation- It is important to ensure the subfloor on which the sheet is being laid is smooth, flat, hard and free from moisture, grease etc. In case of uneven subfloor the same should be levelled using self leveling compound which will charged extra. The moisture present in the subfloor should be less than 8% before installation of the floor adhesive. The installation shall be undertaken as per manufacturers installation instructions.
Providing & fixing Rockfone Stonewool Acotsical Ceiling PACIFIC High NRC (0.80), Fire Rating A1 (EN 13501-1), RH 100% (No visible deflection in high humidity), Superior Class Light Reflection, Sag Resistant 12mm thick Ceiling Tiles of size 600x600 A-Edge (Square) with AntiBacterial Properties & M1 Class Emission Certification made up with Natural Stone (Bassalt Rock) a complete Green Product & perfect suitable for any kind of False Ceiling application in builiding & costruction. The Visible side is a smooth white painted fleece, the Rear side: back fleece with complete facctory finish Painted edges.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.
The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all Tsections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
With 16 mm thick beveled tegular mineral fibre Antimicrobial false ceiling tile confirming to ISO 5 (class 100 ) specifications
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
Supply and installation of Wallflex PUR Vinyl Sheet wall covering manufactured by Armstrong World Industries, Inc or equivalent, 1.5m wide, having a nominal total thickness of 1mm. The nominal thickness of the wear layer would be 1mm. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVC, Plasticizers, Urethane, color pigments and filler calendared to form a sheet. Colors shall be dispersed throughout the thickness of the wear layer. Wallflex shall conform to Group M of Wear Resistance as per EN 660-2, Fire resistance of group 2 as per AS/NZS3837, Residual indentation of ≤0.10mm as per EN433, curling after exposure to moisture ≤8mm as per EN434, Seam strength of mean≥240N/50mm as per EN684.
WATERPROOFING WORK AND ROOF WORK
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :v) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. vi) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.vii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. viii) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
Water proofrng for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :-
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd.
/ MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat For the purpose of measurernent tte entire treated surface will be measured."
(c) :2nd Coat:- To apply the 2nd coat of two component acrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/c.
The Watqrproofing Brand:*Sil<a Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A.Acrylic copol;,mer, Part 13 Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +270C Tensile Strength -2 N/mm2 after 28 Days (with Fibre cloth) (According to ASTM D 2370)Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.
4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (According to ASTM D 2370)
D Protection of treated with pcc :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( 1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. integral water proofing admixture conforming to lS 2645 @ of 100 ml perbag of of cement to be added in the screed concrete (paid separately for thts ltems
all corners shall be charfered with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose of measurement the entire treated surface will be measured."
(e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc
Covering of treated surface wrth PCC :- Providing 50 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
Covering of treated surface wrth PCC :- Providing 50 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
Provrding and filling of Groove between 50 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and Technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement laster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
FINISHING WORK
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5with 5% cico or any other approved water proofing compoundincluding taxes and royalty all complete as per building specification and direction of E/l.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Providing two coats of Synthetic Enamel paint of Approved shade & make over Steel Surface
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. One or more Coats
Finishing walls with 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Finishing walls with textured exterior paint of required shade:New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coat applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
WALL CLADDING WORK
Providing and laying of 2 - 3 mm average thick layer of cementations smoothening compound of UZIN NC 149 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer over and including a priming compound of UZIN PE 360 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer and installation team on concrete surface to provide a smooth & homogenous surface for laying of vinyl sheet flooring complete to the entire satisfaction of Engineer-in-charge.
CARRAIGE OF MATERIALS
SAND ( 10KM )
CHIPS ( 22 KM )
METAL ( 22KM )
BRICKS ( 1+7KM )
MISCELLANEOUS WORK
Supplying, installation, testing & commissioning of MACHINE ROOM LESS 20 passenger lift /1360kg/1.25 m/s speed / 6 floor / 6 stops / stainless steel ( 1.5mm ) Car cabin, Differently Abled people friendly. Provisions of General CPWD specifications for lift works are to be followed. Controller - Micro processer based AC variable voltage & variable frequency Control Automatic rescue device complete with dry maintenance free batteries as required. Operation - Microprocessor based Simplex Full Collective without attendant. Power - 415 V ±10%, 3 Phase, 50 H Car door - Power operated centre opening horizontal sliding stainless steel Scratch resistant Door operation - Full Height Infra-red cross-multi beam Landing doors - Centre opening, stainless steel scratch resistant at all floors. It must be fire-rated for minimum 1-Hrs and supplier must provide the certificate for the same along with material supply. Car operating Panel / Landing operating panel - Only Emergency button Inside the Car Hand rail - Shall be SS finish fixed above 900mm from the car-floor level on rear-wall or side wall. Voice announcement system - In car to announce the position of the elevator in hoist way as the car passes or stop at a floor served by the elevator Intercom system - 3-way intercom Clear Opening of Doors - 1000 X 2000 mm (Wide x Height). Makes - Johnson, Kone, TKE, Schindler
Demolishing of existing passenger lift in all complete as per engineer in charge.
STRUCTURE REPAIR & RESTORATION
Stagging/Supports/Scaffoldings
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
Removal of Unsound Concrete & Chipping of Concrete
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
75mm average thickness
50mm average thickness
25mm average thickness
Rust Removal, Anti corrosive coating & Galvanic sacrificial Anodes : Corrosion Treatment
Providing and applying Reebaklens RR, a combination of acid based material, corrosion inhibitors and dispersing agents rust remover, for removal of all rust/ scales/corrosion from reinforcement bars before microconcreting or patch repair, having Specific Gravity 1.16-1.22 @25°C. Reebaklens RR Shall be applied with brush for complete wetting of rusted metal surface at coverage of 2-2.5 Sqm/ltr. & allow it to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal /steel for about 5-7 days. Before applying any protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth. (Mode of measurement- per sqmt of breaking area of concrete)
Provide and install sacrificial zinc anodes Fosroc Galvashield XPI, to prevent the initiation of corrosion in steel reinforcement within chloride-contaminated or carbonated concrete, or in new construction. Each anode unit must contain a minimum of 60 grams of zinc, compliant with ASTM B418-95a, Type I, die-cast around steel tie wires, ensuring proper separation if multiple tie wires are used. The anodes must be encapsulated in a highly alkaline cementitious mortar with a pH of 14 or higher, free from sulfates, chlorides, bromides, or any other corrosive elements to steel. The encapsulating mortar should feature an interconnected and fine pore structure to dissolve, transport, and accommodate zinc corrosion products away from the anode surface without causing additional stress to the concrete cover, maintaining a pH > 14 near the uncorroded zinc for the specified service life. Anode units shall be supplied with integral, well-separated tie wires (without splices if multiple wires are used) and loop ties for direct attachment to the reinforcing steel. Anodes should be covered with a bed mortar with resistivity less than 50 kOhm-cm or similar to the parent concrete on cleaned steel reinforcement before applying passivation coating. The scope includes supply, installation, spacing calculations, quality assurance procedures, and must adhere to manufacturer specifications. Approved brand shall be M/s Fosroc Galvashield Anodes/Vector Galvashield/IPSS
1. Spacing at column shall be at 600mm C/C
1. Spacing at slab shall be considered as 2 Nos. in 1 Sqm.
Providing and applying Nitozinc Primer an epoxy based zinc rich anti corrosive primer having adhesive bond strength ≥ 1.5 MPa as per ASTM D4541, & shall comply to per ASTM B-117 to be applied on well cleaned, fully exposed and all loose scale, rust free surface obtained by grit blasting or suitable means, to be done with coverage @4.5sqm/litres to achieve a minimum thickness of 40 microns DFT or as per direction of Engineer-In charge. (Mode of measurement- per sqmt of breaking area of concrete )(Fosroc- Nitozinc Primer & Sika- Sika® FerroGard®-950 IN
Crack repair/Epoxy grouting
Surface Preparation: Make a 'V' groove 5 mm wide and 5 mm deep over the crack line using an electrically operated angle grinder with a diamond concrete saw blade. Clean the groove thoroughly with an air blower as directed by the Engineer-in-charge.
Sealing with Epoxy Repair Mortar: Seal the exposed 'V' groove (5 mm deep, 5 mm wide) with a solvent-free, moisture-tolerant, thixotropic, two-part structural adhesive and epoxy repair mortar cum surface leveling mortar. Ensure the epoxy repair mortar has compressive strength ≥ 60 N/mm² (7 Days, BS 6319), flexural strength ≥ 20 N/mm² (7 Days, BS 6319), and tensile strength ≥ 10 N/mm² (7 days, ASTM C 307). Use products like NITOMORTAR S OF FOSROC, Sikadur®-31 of Sika, MasterBrace 2200 BASF, or equivalent of Pidilite.
NRV Nozzles Installation: Drill and fix NRV nozzles in RC members, including (fixing material: Renderoc Plug of Fosroc / Sikadur-31 of Sika/ MasterBrace 2200 of BASF or equivalent of Pidilite& Krishna Conchem). Drilling Holes: Drilling 12 mm dia, 50 to 75 mm deep holes or upto required depth in structural members of the intervals of 350 mm in staggered manner or as directed by the Engineer-in-charge in RC structural elements. Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. Fixing of Nozzles: Insert 12mm dia. NRV nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun. Fix it inside the holes by applying thyrotrophic epoxy putty to ensure complete sealing. Cure the system for min. 12 hrs. Cuttting of Nozzles: Cut the nozzles by chisel after completion of grouting without damaging structural elements.
Pressure Grouting with Epoxy Resin: Perform pressure grouting using Conbextra EP10, a low viscous solvent-free two-component epoxy resin with a density of 1050 kg/m³. Ensure the epoxy resin has viscosity < 0.6 poise (ASTM D1200), compressive strength > 80 MPa (ASTM D 695), and bond strength > 4 MPa (ASTM C882). Use products with CE marking and compliance according to Construction Products Directive 89/106/EEC. Mix epoxy resin components in required quantities as per manufacturer's instructions. Fill the grouting gun with epoxy resin and maintain desired pressure using an air compressor. Grout the material through prefixed nozzles in structural elements until refusal, sealing the nozzles with epoxy putty afterward. Monitor and seal leakages through other nozzles as required. Complete the operation within the pot life of the material. Clean the grouting gun and accessories with thinner after the operation to prevent jamming. (Low Viscous epoxy grout : conbextra EP10 of Fosroc/ Sikadur®-52 of Sika/ MasterInject 1315 of BASF or equivalent of Pidilite).
Water-stopping crack injection resin foam shall be Nitofill WS60, a two-part foaming liquid polyurethane. When mixed in the supplied proportions and injected into concrete cracks, the resin reacts with moving water to create a foam barrier that stops water infiltration. The resin's properties include a pot life of 6-8 hours at 20°C, specific gravity of 1.11 ± 0.03, and foam density of 0.024g ± 0.003. Used alongside Nitofill UR63, a flexible two-part polyurethane injection resin, it ensures a permanent seal in cracked concrete. Nitofill UR63 is a solvent-free liquid polyurethane that, when mixed and injected into cracks, forms a slightly flexible and impermeable barrier in dry and damp conditions. This polyurethane system features a pot life of 60 to 80 minutes at 25°C, reaction time of 70 to 90 minutes at 25°C, viscosity of 40-60 cps at 25°C, and specific gravity of 1.1. When combined with Nitofill WS60, the foaming polyurethane resin, it guarantees a durable seal in cracked concrete.
Nitofill WS60
Nitofill UR63
Reinforcement bar/ Rebaring
For Shear Connector/Ties/Stirrups: Supply and fixing of shear connectors/ties/stirrups using rebars of designated dia for column/beam/Shear walls etc at designed embedement length wherever required , including power drilling, cleaning of holes, then rebars should be inserted in holes that should be filled with FIS V Plus of Fischer or equivalent, hybrid based rebarring chemical with ETA approval, DIBt, approved for diameter range from 8 mm to 28mm reinforcement bar as per manufacturer's specification as per the direction of Engg In-charge. Drilling of hole should be done upto provided embedment depth as per the design from manufacturer approved by EnC, followed by cleaning with blow pump, wire brush and blow pump for 4 times, complete as per the manufacturer's methodology. The chemical shall have tested service life of 50years as per ETA. Cost of providing, cutting, bending of rebar shall be paid separately as per approved item.
At 10D Depth
For 8mm x 100mm
For 10mm x 100mm
For 12mm x 120mm
For Main Reinforcement: Supply and fixing of main reinforcement using rebars of designated dia for column/beam/Shear walls/Foundations at designed embedement length wherever required , including power drilling, cleaning of holes, then rebars should be inserted in holes that should be filled with FIS EM Plus of Fischer or equivalent, a heavy duty pure epoxy based rebarring chemical with ETA approval, DIBt, approved for diameter range from 8 mm to 40 mm reinforcement bar as per manufacturer's specification as per the direction of Engg In-charge. Drilling of hole should be done upto provided embedment depth as per the design from manufacturer approved by EnC, followed by cleaning with blow pump, wire brush and blow pump for 4 times, complete as per the manufacturer's methodology. The chemical shall be approved for diamond-drilled and water-filled drill holes as well as seismic applications in performance categories C1, C2 for rebar connections. Product shall have test certificate for 120years of service life & shall have ETA complying to EAD 332402-00-0601-v01. Cost of providing, cutting, bending of rebar shall be paid separately as per approved item.
At 15D Depth
For 12mm x 180mm
For 16mm * 240mm
For 20mm * 300mm
For 25mm * 375mm
For 32mm * 480mm
Epoxy bonding agents for bonding old Concrete & Repair materials
Providing and applying bond coat on the prepared surface with two component epoxy based bonding coat Nitobond EP of Fosroc make or equivalent, having specific gravity 1.15 to 1.2 gm/cc,. The bonding agent shall be applied by brush & should remain in tacky state after application for a minimum period of 5-6 hrs at 20 deg C & 2-3 hrs at 30 deg C. Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat.
Supply and apply Nitobond AR, an acrylic-based emulsified solution containing a minimum of 43% solids and compatible with cementitious materials. The bonding agent shall provide sufficient bond strength when applied directly on concrete or when mixed with neat cement. Ensure proper application to achieve effective adhesion between substrates and subsequent layers of cementitious materials, adhering to manufacturer's recommendations for optimal performance and durability in construction applications. Nitobond AR is particularly suitable when a longer working period after applying the bonding agent is required
Microconcrete
Provide and apply single-component, free-flowing, non-shrink cementitious microconcrete at a water-to-powder ratio of 0.15. The microconcrete should have a fresh wet density of 2200 kg/m³ at 27°C and an unrestrained expansion of 1 to 4% as per ASTM C827. It must achieve a flowable consistency and compressive strength of not less than 10 N/mm² after 24 hours, 35 N/mm² after 7 days, and 45 N/mm² after 28 days at 30°C. The cured microconcrete shall be free from metallic aggregates and chlorides, and it must be shrinkage-compensated in the plastic state. Payment will be based on the consumed dry material of the microconcrete mix (Product :- Renderoc RG 45 of Fosroc/ SikaRep® Microcrete -4 of Sika / MasterEmaco S-346 of BASF or equivalent of Pidilite)
a) Without addition of aggregate
b) With addition of 6 mm down aggregate in 3:1 (3 Micro concrete: 1 aggregate 6 mm & down)
Providing mixing & applying pre-batched one component polymer modified dual shrinkage compensated thixotropic cementitious patch repair mortar as per the manufacturer specifications and as per the direction the Engineer-in-charge. The compressive strength of polymer modified mortar shall be ≥ 45 Mpa (28 Days) according to (BS 1881 Pt.116), Flexural strength >7 N/mm2 at 28 days (BS 6319 Pt.3) and Tensile strength >2.5 N/mm2 at 28 days (BS 6319 Pt.7). (Product :- Renderoc SP40 of Fosroc/ SikaTop® 122 HS of Sika / MasterEmaco S 348 of BASF or equivalent of Pidilite)
For 20 mm thickness over slab, beams, columns and stair case slabs
Add/ deduct for every 10 mm thickness
Curing Compound
Supply and apply Concure WB White, a water-based concrete curing compound, to prevent premature water loss from freshly placed concrete. Ensure complete coverage of all exposed concrete surfaces according to manufacturer's recommendations for effective curing and hydration, promoting optimal strength development and durability of the concrete structure
Strengthening: Carbon fibre wrap/Carbon Laminates
Providing and applying uni directional, high strength carbon fiber sheets Nitowrap CWS of 450 GSM/ dry fabric thickness.The FRP fabric used shall be of zero degree unidirectional fibers having fiber density of 1.8 g/cc and shall have tensile strength > 4900 MPa ; tensile modulous > 230 GPa and ultimate elongation of 2.1%. The substrate shall be primed with Nitowrap 30 epoxy primer & Nitowrap 410 impregnating resin saturant shall be used for saturating the fibers. Saturant used shall have tensile strength of >30 MPa; Elongation > 2% ; Flexural strength > 30 MPa ; Tensile Modulous > 2400 MPa & Flexural Modulous > 1700 MPa when tested as per ASTM D638 Type I and ASTM D 790 & Glass Transition Temperature > 50 deg Celcius as per ASTM E 1356.The adhesion of the entire system(FRP Sheet, Saturant and primer combined) with concrete shall be > 3.5 MPa with concrete failure as per ASTM D 4541. (Product :- Nitowrap CWS of 450 GSM of Fosroc, Sikawrap® 930 G of Sika / MasterBrace FIB 73/900 of BASF) Surface preparation: Grinding/ moulding concrete substrate cleaning it with wire brush removing oil, laitance if present, rounding sharp edges to min 25mm radius etc. complete. Profiling : Applying compatible primer of approved make and brand on prepared substrate, filling the holes and uneven surface with thixotropic putty etc. complete. Wrapping : Wrapping the fiber sheet with recommended overlapping to structural element at desired oriention using tamping roller to avoid any air voids etc. repeat the same procedure for multiple layer with the interval of 8 hrs. Sand Pasting : Applying second coat of saturated after 12 hrs. rectify air voids if any, paste the coarse sand on it to make surface rough to take any further finishes (Mode of measurement : Per sqm surface area of application per layer).
Supply and install fiber anchors to be embedded at a depth of 75 mm with 75 mm protrusion, spaced at 500 mm center to center. (Product make: Fosroc/ Sika/ BASF)
Providing and applying Carbon Fiber FRP Pultruded Laminate strips Nitoplate CPS to the prepared substrate using thixotropic epoxy adhesive. The FRP laminate used shall be of zero degree unidirectional fibers having volumetric fiber content of 68%, fiber density of 1.5 g/cc and shall have tensile strength of 3000 MPa ; tensile modulous of 165 GPa and ultimate elongation of 1.7%. The thixotropic epoxy bonding adhesive shall be applied at 1mm thickness on the substrate and 2mm thickness on the laminate. The adhesion of the entire system(Laminate and adhesive combined) with concrete shall be > 3.5 MPa with concrete failure as per ASTM D 4541. The adhesive used shall have tensile modulous > 2700 MPa (ASTM D638) ; flexural modulous > 48000 MPa (ASTM D790 ) ; Elongation > 2.5% & Glass Transition TemPerature > 100 deg C (ASTM E 1356). The ends of the laminates shall be anchored suitably.,etc complete. Laminates shall be having 1.4mm Thickness and 100mm width.
Exposed surface area painting
Supply and apply Dekguard E2000, a high-performance elastomeric protective anticarbonation coating for concrete and masonry. The protective coating system includes a penetrating silane-siloxane primer (Dekguard Primer) and a single-component elastomeric anticarbonation aliphatic acrylic coating (Dekguard E2000). Ensure the total dry film thickness of the protective coating system is not less than 200 microns. The coating system shall provide CO2 diffusion resistance of at least 50 meters (equivalent air layer thickness), static crack accommodation of minimum 2mm, and adhesion greater than 1.0 N/mm² as per ASTM D 4541. The product used must meet specified performance standards for durability and protection against carbonation. Apply in accordance with manufacturer's guidelines to ensure effective long-term performance and adherence to project requirements
FURNITURE WORK
Providing and Fixing reception backdrop panneling 150mm thick size as per drawing , made in hard wood frame(mirandi wood) 50mm x 50mm thick & c/c 600mm maximun both ways joint rigidly horizontally & vertically with nails, screws etc. fixed to wall/ceiling & columns with wooden plugs. 11 mm thick MDF Board is to be fixed on top of frame with 10x8 mm deep grooves on both sides of the center panel. 11mm MDF Board is to finished with laminate on both side of approved design and all groves to be finished with laminate shade. Center panel is of 19mm MDF jali /Engg. stone cladding of aprooved design and of size: The visible part through MDF Jali is to be finished with lacqured glass of approved design. All work is to be carried out as per drawing and instructions of engineer in charge. ( MDF Board/ MDF Jali & Laminate Make Green ply/Century /Merino or Equivalent ), (Adhesive make Pidilite or equivalent)
Providing and Fixing reception backdrop panneling 150mm thick size as per drawing , made in hard wood frame(mirandi wood) 50mm x 50mm thick & c/c 600mm maximun both ways joint rigidly horizontally & vertically with nails, screws etc. fixed to wall/ceiling & columns with wooden plugs. 11 mm thick MDF Board is to be fixed on top of frame with 10x8 mm deep grooves on both sides of the center panel. 11mm MDF Board is to finished with 4mm veneer on both side of approved design and all groves to be finished with shade. Center panel is of Engg. stone cladding of aprooved design and of size: The visible part finish with melamine polish and mirror polish of approved design. All work is to be carried out as per drawing and instructions of engineer in charge.
Providing and fixing reception table made out of 19mm thick commercial board with working platform to be made out of 19mm thick corian Top of approved shade. The reception table will consist of vertical support in front and sides of 19mm thick commercial board finished with 1mm thick laminate of approved colour, pattern,texture and shade. All internal surfaces to be enamel painted. Counter should have the mobile pedestal unit of size 450mm wide and 750mm height.The pedstal unit should have 1 no. of drawer & remaining space should be made storage with shutter.The darwer shall be made out of 19mm thick commercial board for the sides & base shall be of 6mm thick commercial plywood with wooden lipping all around.The drawer is to be mounted on telescopic drawer channel on G.I. guides. All edges of working platform to be provided with moulding of size 30mm x 40mm finished in melamine polish of approved shade. On front face a decorative panel to be placed made out of 19mm thick board finished in 1mm thick laminate of approved shade. 1.5 mm thick acrylic sheet facia supported by 4nos. of S.S. member and 12mm thick mdf jali facia combination to be placed over decorative panel all complete as per drawing and instructions of Engineer in charge.
GROUND FLOOR DOUBLE HT ENT. HELP DESK reception table of size 4600 x 600 x1050 (1 NOS side unit 4000X600X750) (LEFT SIDE)
GROUND FLOOR DOUBLE HT ENT. HELP DESK reception table of size 3700 x 600 x1050 (1 NOS side unit 3100X600X750) (LEFT SIDE)
GROUND FLOOR DOUBLE HT ENT. HELP DESK reception table of size 3700 x 600 x1050 (1 NOS side unit 3100X600X750) (RIGHT SIDE)
P/Fixing Wall paper as per approved brand and manufacture to give an even shade and color as approved by architect. & instructionof Engineer in charge.
Providing and Fixing MDF Wall Panneling made in hard wood frame (mirandi) 35mm x 50mm thick c/c 600mm horizontally & vertically, fixed to wall/columns with wooden plugs,then 11 mm thick Medium Density Fiber Board fixed on top of frame with 10x8 mm deep Groove & same finished with 1.0 mm thick laminate of approved quality pasted with the help of adhesive with provision of pin up board for backlit , making of niche as /dwg fixed nails screws etc. All grooves to be finished with lacquer polish maching with laminate shade as per Technical specification, drawing and instructions of Engineer in charge.
Providing & Fixing premium quality Roller blinds Micro-Aerated - coated fabric to provide subtle view of the side of the blind and insulates and dissipates heat.Fabric shall be recycleable. Composition: 40% Polyester / 60% PVC Weight:400 g/m2 (+/-5%)Thickness:0.45 mm (+/-5%)Fabric Openess Factor: 4%Visible Light Transmission: 3% - 5% (N-N)Solar Transmission : 4% - 21%Solar Transmission : 4% - 21%Solar Reflectance : 7% - 70% Solar Absorption : 9% - 89%Tensile Strength (Warp/Weft): 220/220 daN / 5cmTearing Strength (Warp/Weft): 30/25 daN Management system for Quality : ISO 9001 Fire Retardancy:M2 (NFP92-507)Fabric Warranty: 5 Years Roller Tube shall be of extruded Aluminum alloy 38mm O.D (or as per system dimension) with a minimum wall thickness of 1.0mm duly anodized for long life. Clutch shall be wrap spring design with high strength fiberglass reinforced polyester assembly and high carbon steel springs to transmit motion from driving to driven members of clutch mechanism. Clutch shall operate by directionally with the use of an endless beaded chain. Clutch mechanism shall be crash proof, prevent slippage and shall raise and lower smoothly to any desired height. Clutch shall never need adjustment. Idler shall be of high strength fiberglass reinforcedpolyester, consisting of an outside sleeve and center shaft. Sleeve shall provide bearing surface for roller tube and rotate freely on center shaft, providingsmooth,quiet and long wearing operation. Brackets shall be of atomized steel powder coated to give superior finish. Bracket shall accommodate overhead, side or face mounting with clutch assembly on either end of the roller. Bottom of the blind shall be provided with aluminum tube powder coated. The fabric shall be enclosed in the suitably created pocket along with the tube. The tube shall be closed from sides with end caps to give a neat look. The blinds shall be of mullion to mullion width.
Providing & Fixing laminated wooden false ceiling , made in 50x50mm Hard wood frame (Mirandi) center to center 600mm both ways, hang to ceiling with help of hanger support 'L' type G.I angle (25x25mm) and anchor bolt etc. over fixed 11mm thick MDF board with 10x8mm deep groove finish with lacqure polish, 1.0 mm thick approved shade laminate to fixed on MDF board, defects free bubbles free with help of adhesive. as per drawing and to the entire satisfaction of Engineer in charge.
Providing and making cove in gypsum board false ceiling with all accessories.as per drawing and instructions of Engineer in charge .
Providing and Fixing 50mm extruded Acrylic LED backlit indoor signage for reception back wall as per as per design/art work/logo ,direction by architect.
Providing and Fixing false ceiling made in Channelled Woodworks perforated panels of width 128mm, thickness of 16mm and length 2440 mm , made of a high density particle board substrate with a laminated / veneered facing as per the approved shade/ species & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a (“Helmholtz” fluted perforation of 2mm width and 14mm of visible panel / 4mm width and 28mm visible panel) each. The panels shall provide a minimum sag resistance of RH90 and a fire rating class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece. The panels shall be mounted on special aluminium splines using clips. Installation: Install wooden battens of section 50mmx50mm on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for channelled woodworks (GTPT001) provided by Armstrong over the lowest and second wooden batten at an on-center distance of 600mm. Install the first set of wooden panels by inserting the clips for border channelled woodworks (GTPT002) and insert the groove of the panel into the projecting flange of the aluminium clip.
Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing clips for inside channelled woodworks (GTPT003) into the next keel till the actual height is achieved. Use clips for border channelled woodworks (GTPT002) to finish off the installation. Finish off the edges using wooden moulding of matching colour complete in all respects & to the instruction of Engineer in charge.
Providing and Fixing Wall paneling made in Armstrong Channelled Woodworks perforated panels of width 128mm, thickness of 16mm and length 2440 mm , made of a high density particle board substrate with a laminated / veneered facing as per the approved shade/ species & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a (“Helmholtz” fluted perforation of 2mm width and 14mm of visible panel / 4mm width and 28mm visible panel) each. The panels shall provide a minimum sag resistance of RH90 and a fire rating class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece. The panels shall be mounted on special aluminium splines using clips. Installation: Install wooden battens of section 50mmx50mm on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for channelled woodworks (GTPT001) provided by Armstrong over the lowest and second wooden batten at an on-center distance of 600mm. Install the first set of wooden panels by inserting the clips for border channelled woodworks (GTPT002) and insert the groove of the panel into the projecting flange of the aluminium clip.
Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing clips for inside channelled woodworks (GTPT003) into the next keel till the actual height is achieved. Use clips for border channelled woodworks (GTPT002) to finish off the installation. Finish off the edges using wooden moulding of matching colour complete in all respects & to the instruction of Engineer in charge .
P/Fixing wooden beam on ceiling made in 19mm thick com board finish with 4 mm.thk.specified veneer with melaminae polish all complete with drawing ,all woods parts to be finish in melamine polish.
ADMINISTRATIVE FURNITURE WORK
Providing and supplying HNI or equivalent R 1 Registration Table having Dimension L SHAPE SIZE - 4800/3600 X 600/600 X 1050 Height . It has 25mm thick Worktop and Gable Ends made of pre Laminated Particle Board sealed with PVC Edge Banding. Front and Modesty Panel are 18mm thick Pre Laminated ParticleBoard Sealed with PVC EdgeBanding . The Counter Top is 25 mm Thick Postformed ParticleBoard.Table has a Laminate pedestal unit having Dimension 400mm W x 450mm D x 635 Ht and shall consist of One pencil tray, 2 drawers and one filing box. It is made of 18mm prelaminated particle board . It shall be provided with 2 lockable and two free twin wheeled castors. The pedestals shall have central locking mechanism. It has roller slide mechanism for 2 Drawers and Ball bearing slide for 1 Filng Unit.The pencil tray shall be made of 2mm moulded HIPS and shall be fitted inside the first drawer. It should freely slide in horizontal direction. The pencil tray shall have necessary compartments (Miniumum 3 compartments) for keeping stationary items. Warranty 5 years .
Providing and supplying HNI or equivalent R 1 Registration Table having Dimension L SHAPE SIZE - 2400/2250 X 600/600 X 1050 Height . It has 25mm thick Worktop and Gable Ends made of pre Laminated Particle Board sealed with PVC Edge Banding. Front and Modesty Panel are 18mm thick Pre Laminated ParticleBoard Sealed with PVC EdgeBanding . The Counter Top is 25 mm Thick Postformed ParticleBoard.Table has a Laminate pedestal unit having Dimension 400mm W x 450mm D x 635 Ht and shall consist of One pencil tray, 2 drawers and one filing box. It is made of 18mm prelaminated particle board . It shall be provided with 2 lockable and two free twin wheeled castors. The pedestals shall have central locking mechanism. It has roller slide mechanism for 2 Drawers and Ball bearing slide for 1 Filng Unit.The pencil tray shall be made of 2mm moulded HIPS and shall be fitted inside the first drawer. It should freely slide in horizontal direction. The pencil tray shall have necessary compartments (Miniumum 3 compartments) for keeping stationary items. Warranty 5 years .
Providing and supplying HNI or equivalent Model Certo Medium Back Chair .This is a Medium back chair with Mesh Back with back tilt tension adjustable . The chair has Anchored Lumber Support . The Chair has Nylon base with 50 mm twin wheel castors .Chair comes with 1-D adjustable PP armrests . Seat size is 500 mm W x 520 mm D and the Chair Height 985 mm - 1080 mm . Overall size of the chair is 635mm W x 605 mm D x (985 mm- 1080mm) H . The PU foam used for chair seat is fire retardant . The chair has Pneumatic Gas Lift with Stroke=85 mm . WARRANTY: 3 Years from the date of invoice .
Providing & Supplying HNI or equivalent Make Cabin Table with Main Table Dimension 1650mm L x 750 mm D and side storage 900mm L x 450mm D . The Worktop is made of 25mm thick Prelaminated particle board with 2 mm thick PVC Lipping on the edges. The worktop is supported on U Shape Metal Legs 50mm x 50mm , powder coated understructure with Laminate Modesty panel. The Metal legs are connected by Metal Beams for stability and . The Table tops should have metal inserts on underside for modularity. The screw used should be blunt headed and not sharp headed for metal to metal coupling . Colour as per direction of Engineer in Charge. Side Storage unit is made of combination of hinged door unit and 3 Drawer unit - Storage body is made of 18mm thick pre laminated partical Board conforming to IS : 12823. The back of the unit is made from 18mm prelaminated board. All the exposed edges are with 2mm PVC egde Imported banding & sealed edges are with 0.8mm thick PVC Imported edge banding. The top, side and hinged shutters are sealed with 2mm thick PVC edge banding. The units are assembled by knock down fittings such as Minifix & Dowels. All the hardware and Hinges are from Hettich/Ebco. Warranty 5 years .
Providing and supplying HNI or equivalent Model Quip High Back Chair with head rest .This is a High back chair with Mesh Back with back tilt tension adjustable . The chair mesh is available in 6 different colours ( Green / Ruby / Cinnamon / Magenta / Indigo / Black ) with matching or contrast seat fabric according to the choice of the client..The chair has Adjustable Lumber Support . The Chair has Nylon base with 60 mm twin wheel castors .Chair has 1-D adjustable armrests with PU Pads . Seat size is 490 mm W x 435 mm D and the Chair Height 1135mm - 1225mm . Overall size of the chair is 640mm W x 665mm D x (985 mm- 1220mm) H .The chair has Pneumatic Gas Lift with Stroke=85 mm . Chair carries a warranty of 5 years.
Providing and Supplying HNI or equivalent Visitor Chair 1. Leatherette Upholstered Seat & Back 2. Seat Size-530 mm W X470 mm D 3. Back Size – 530 mm W X460 mm HT 4. Base - Powder Coated fixed Base 5. Overall Chair Size - 618 mm W X 615 mm D X 815 mm H . Warranty 3 years .
Providing and Supplying HNI or equivalent Lab Stool with Seat Dia minimum 30 cm. The seat should be made up of 12mm thick hot pressed plywood upholstered with fabric / Leatherite and moulded polyurethane foam. Chair should be on a 4 legged Metal Pipe frame assembly with Height adhustability for seat and is duly powder caoted and provided with gliders as per manufacturer's specifications, drawings & direction of Engineer in charge. The above furniture should be as per specification and sample approved by client.
Providing & Supplying HNI or equivalent Make Cabin Table with Main Table Dimension 1650mm L x 750 mm D and side storage 900mm L x 450mm D . The Worktop is made of 25mm thick Prelaminated particle board with 2 mm thick PVC Lipping on the edges. The worktop is supported on U Shape Metal Legs 50mm x 50mm , powder coated understructure with Laminate Modesty panel. The Metal legs are connected by Metal Beams for stability and . The Table tops should have metal inserts on underside for modularity. The screw used should be blunt headed and not sharp headed for metal to metal coupling . Each Table has 3 Drawer Laminate Pedestal with Castors 400mm W x 450 D x 680mm Height . Back Storage 2400W X 450D X 750H is a hinged door unit and its body is made of 18mm thick pre laminated partical Board conforming to IS : 12823. The back of the unit is made from 18mm prelaminated board. All the exposed edges are with 2mm PVC egde Imported banding & sealed edges are with 0.8mm thick PVC Imported edge banding. The top, side and hinged shutters are sealed with 2mm thick PVC edge banding. The units are assembled by knock down fittings such as Minifix & Dowels. All the hardware and Hinges are from Hettich/Ebco.
Providing and supplying HNI or equivalent Model Quip High Back Chair with head rest .This is a High back chair with Mesh Back with back tilt tension adjustable . The chair mesh is available in 6 different colours ( Green / Ruby / Cinnamon / Magenta / Indigo / Black ) with matching or contrast seat fabric according to the choice of the client..The chair has Adjustable Lumber Support . The Chair has Nylon base with 60 mm twin wheel castors .Chair has 1-D adjustable armrests with PU Pads . Seat size is 490 mm W x 435 mm D and the Chair Height 1135mm - 1225mm . Overall size of the chair is 640mm W x 665mm D x (985 mm- 1220mm) H .The chair has Pneumatic Gas Lift with Stroke=85 mm . Chair carries a warranty of 5 years.
Providing and Supplying HNI or equivalent Metal Waiting chair Model ES 909 having Seat made of Perforated Cold Rolled Steel Epoxy Powder coated having thickness of 1.2mm . Arms and Legs are made of Aluninium for superior Strength and durability. Seat Seat Frames are supported on Steel Beams with thickness of 2mm duly powder coated. Seat and Back are single piece duly Epoxy powder coated.
Providing & Supplying HNI or equivalent Locker Steel Single Tower Locker Cabinets with in built Locks having dimension of 1800mm H x 460mm D x 390mmW made of 0.8 mm thick CRCA sheet duly powder coated to thickness of 40-60 micron.Each vertical unit has SIX Nos Locker unit. Each unit has independent door with concealed hinges and 7 lever cam lock and label holder the product has leveler for good ground support. All the components are finished 40 to 50 microns thick epoxy polyester powder coating oven baked at 180 to 200 deg.C. The above furniture should be as per specification and sample approved by client. Model LR 6
Providing and Supplying HNI or equivalent R 2 Model Reception and Registration Counter . It is Made of 50mm thick Metal frame and Laminate finish on both side of frame . The Reception Table Frame Height is 1050mm and is provided with a counter top at this Height. Counter Top is running along the Entire Length of Counter and has Depth of 450mm and thickness of 25mm with PVC 2mm Edge Banding. The Working top inside the reception table is at 750mm Ht and has 600mm Depth and 25mm thickness. All Table tops and Counter tops are made in PLPB with 2mm PVC edge banding on user side and 0.8mm on other sides. A divider Frame is given every 1050 mm Length till height of 1350mm . Frame is made of 50mm Partition with Laminate Finishing Tile on both sides. Clear Glass 12 mm thick is provided above counter top from 1050mm Ht till 1500mm Height . Glass has polished edges and is fixed with D brackets with Counter Top and and also with Divider frame. Glass is provided with a Suitable cut for enabling transaction over the counter top.
4600mm L + 4600 L x 1500mm Ht x 600mm D
2000mm L + 1700 L x 1500mm Ht x 600mm D
4250mm L + 2000 L x 1500mm Ht x 600mm D
HOSPITAL FURNITURE
Supply and Installation of FOWLERS BED(MOTRIZED) Plastic/ABS Bed Head Panels Size of 2030 L x 900 W x 600 H Pre treated and Epoxy Powder Coated, Manually Crank Operated with Hi-Lo postion Frame & Plateform should be made of CRCA steel with100 mm Swivel castor, along with Matress on site. Including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of FOWLERS BED Plastic/ABS Bed Head Panels Size of 2030 L x 900 W x 600 H Pre trated and Epoxy Powder Coated,Manually Crank Operated with Hi-Lo postion Frame & Plateform should be made of CRCA steel with100 mm Swivel castor, along with Matress on site. Including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of BED SIDE LOCKER Single Storgage box,Size of 400 L x 400 Wx 800 mm H epoxy powder coated ,Frame should be CRCA Sheet/Tube closed on threeside with SS top,having two PVC shpe and two 50 mm castors, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of OVER BED TABLE Frame made of CRCA steel tube with epoxy powder coated,laminated wooden board with adjustable gear. Dimension of top : 750 L x 400 w mm ,Table stand on 50 mm castors, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of Pre treated epoxy powder coated SS revolving stool made of CRCA steel tube with four leg height adjustable upto 675mm,reinforced with steel frame.Foot rest ring on PVC shoes, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of SS STOOL HDU/ICU BED/SICU BED ICU Bed having four function with high low, backrest & knee rest functions powered by means of three actuators. The fourth function of trendelenburg can be adjusted with manual crank. Overall Sizes (in mm): 2312L X 1060W X Adjustable from 490-770H Lying Surface: Sheet metal Lying surface of 1.2mm thickness. Lying surface area consists of mattress retainer to define the position of the mattress. Castors: High endurance Plastic injection molded castors with dual locking arrangement diagonally placed. Wheel Dia. 125mm & Stem dia is 22mm. Diagonal locking provides better stability to bed in locked position. Mattress: 4 Section Mattress 100mm thk for ICU Bed. FOAM Density: 40±2 kg/m3 & Hardness in Kg: 45±2 as per IS:7888 for 25% Compression. UPHOLSTRY Stitched Upholstry Cover Material: Helium Heavy A/F F/R SM Color: Navy Blue (350 GSM, 0.45 THK) with Fire Retardent and Antimicrobial Properties, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of examination table, it should be made of sturdy structure with a ratchet mechanism for tilting the backrest .Over all dimension :1830mm(L)X600mm(W)X850mm(H).Leg frame made of MS ERW tube .Leg shoew made of nylon and lying surface of MS Sheet .Ratchet of MS plate .Finishing of powder coating of wpoxy polyester .Max patient weight :135 Kg. including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of PAEDIATRIC BED As per Medikraft Model No.50-1200 G or Equivalent along with Matress on site. Including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of Instrument Trolley (Stainless Steel) As per Medikraft Model No.50-5100 DS or Equivalent, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of Dressing Trolley (Stainless Steel) As per Medikraft Model No.50-5300 DS or Equivalent, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of Crash Console As per Medikraft Model No.55-5800 SM or Equivalent, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of Patient Trolley With Removable Stretcher As per Medikraft Model No.50-7100 or Equivalent, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of Aluminium Alloy Folding Stretcher As per Medikraft Model No.83-2100 D or Equivalent, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of Ultra Emergency cum Recovery Trolley (Hydraulic) As per Medikraft Model No 50-7400 For Equivalent, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of Soiled Linen Trolley (SS) As per Medikraft Model No.50-6000 DS or Equivalent, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge
Supply and Installation of Wheelchair as per Medikraft Model No.Liberty -AT or Equivalent including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge
Supply and Installation of Scrub Station Automatic Wall Mounted ( Double User) As per Medikraft Model No.80-2200 A or Equivalent including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge
Supply and Installation of EXAMINATION COUGH EMERGENCY RECOVERY The emergency trolley should be height adjustable, back rest should be adjustable and have tredelenburg and reverse trendelenburg functions. 2. Overall Size should be in-between L 2100 to L2200 X W (900)mm to W1000mm X (H) Adjustable from 700mm to 1080 mm 3. Bed Frame should be made of ERW 25X50 tube with thickness of 1.6 mm 4. Base frame should be made of ERW 25X50 tube with thickness 0f 1.6mm 5. The bed should have smooth Trendelenburg and reverse trendelenburg function with assist of 2 nos Gas Spring .the gas springs should be of 530 mm length and 168 mm stoke. 6. The bed frame should be height adjustable by assist of Hydraulic Pump stroke of 140mm.It should be smooth functioning and consistent motion during operations is required.7. The trolley should be provided with detachable stretcher which should be have x-ray permeable top made of high pressure compact laminate of 6mm thick. The top should be exceptional chemical and stain resistance. The fixed portion of the top should be 1065 mm (L) x 590 mm (W) and tilted back portion should be 728 mm (l) x 590 mm (W). including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
Supply and Installation of OT TABLE Low height electrically operated Minor Operation Table with the following Speficifations: Overall Length 1800mm & Width 560mm Mattress Support Section Sizes: Headrest section size- 485x260x40 mm, Back rest section size- 505x430x40 mm, Pelvic section size- 510x500x40 mm, Pelvic Extension section size- 510x310x40 mm, Dual joint leg rest section size- 665x245x40 mm, Base foot print: Length -900mm, Width-530mm / 380mm & Height-145mm Ground clearance: 10mm (unlocked position), Mattress thickness: 40mm, including carriage to site and all necessary installation. Complete in all respect as per instruction of Engineer In Charge.
MGPS WORK
Supply Installation, Testing & Commissioning of Medical Gas Pipeline System (MGPS)
Oxygen Supply System
20+20 size Primary Main Oxygen Manifold Free Standing complete with NRvs and pig tail pipes. (Cylinder will be provided by the Hospital)
Fully Automatic control panel for Oxygen Having a constant flow out put of over 2000 lpm at 4.2 bar pressure.
10+10 cylinder Free Standing Oxygen emergency manifold complete with NRVs and pig tail pipes. (Cylinder will be provided by the Hospital)
EMERGENCY Fully Automatic control panel for Oxygen Having a constant flow out put of over 1500 lpm at 4.2 bar pressure.
Oxygen Gas Outlets complete with probe
BPC Oxygen flow meter with Humidifier Bottle. 0-15 L/min standard flow rate.
Oxygen High Pressure Rubber tube white color.
Nitrous Oxide (N2O) System
(8+8) Cylinder size of Primary Main Free Standing Nitrous Oxide Manifold complete with NRvs and pig tail pipes. (Cylinder will be provided by the Hospital)
Fully Automatic control panel for Nitrous Oxide Having a min. flow out put of 1500 LPM at 4.2 bar pressure.
4+4 Cylinder size of N2O Emergency Free Standing cylinder manifold complete with NRvs & Pig tail pipes. (Cylinder will be provided by the Hospital)
EMERGENY Fully Automatic control panel for Nitrous Oxide Having a min. flow out put of 500 LPM at 4.2 bar pressure.
Nitrous Oxide Gas Outlets complete with probe
Nitrous Oxide High Pressure Rubber tube Blue color.
CO2 CARBON DIOXIDE SYSTEM
(8+8). Cylinder size of Primary Main Nitrous Oxide Manifold Free Standing complete with NRvs and pig tail pipes. (Cylinder will be provided by the Hospital)
Fully Automatic control panel for Nitrous Oxide Having a min. flow out put of 1500 LPM at 4.2 bar pressure.
4+4 Cylinder of CO2 Emergency Free Standing cylinder manifold complete with NRvs & Pig tail pipes. (Cylinder will be provided by the Hospital)
EMERGENCY Fully Automatic control panel for Nitrous Oxide Having a min. flow out put of 500 LPM at 4.2 bar pressure.
Carbon Dioxide Gas Outlets complete with probe
Carbon Dioxide High Pressure Rubber tube
Vacuum Pump
It should be quadruplex Oil free Rotary Vane Type to produces the plant output of Tolerance of +/-5% is acceptable in plant flow capacity of 10000 LPM Primary + 10000 LPM as standby.as per tender Spech.
Vacuum Receiver of 4000 Ltrs Capacity.
Bacterial Filter
Vacuum Gas Outlets.
Ward Vacuum Unit with Regulator, Collection Jar of 600 ml with Bracket.
Theatre vacuum unit trolley mounted complete with 1no. of high suction regulator along with twin vacuum collection jar of Polycarbonet of 2000ml with lid.
Vacuum High Pressure Rubber tube Yellow color.
Vacuum Low Pressure tube
Air Compressor (Screw / Scroll)
The design of medical air plant shall fully comply with the requirement of HTM 02-01/ISO 7396 for flow of 7500 LPM+/- 5% in quadruplex configuration. It should be Oil injected Screw air compressor with output at 0.80 Mpa should be equal to or more than 3150 LPM.Modules should run to provide a primary flow rate of 6300LPM+/-5% and one or more or more compressor modules to provide 7500LPM +/- 5% as standby.
Air Receiver of Capacity 2000 Ltrs
3-stage Air Filtration System
Duplex desiccant dryer
Pressure Reducing System
Medical Air 4 Bar Gas Outlets
Medical Air 7 Bar Gas Outlets
Compresed Air High Pressure Rubber tube Black color.
AGSS PLANT SYSTEM
Duplex AGSS PUMP each plant capacity of a minimum 2000 LPM
AGSS Gas Outlets WITH PROBE
AGSS High Pressure Rubber tube
MISCELLANEOUS ITEMS
Combined Electrical Control Panel for Vacuum System, AGSS System and Compressed Air System (Cascading / seq.) complete with plant Room wiring.
Distribution Copper Pipe : Llyod Company with Testing Certificate
108 mm OD x 1.2 mm thick
76 mm OD x 1.2 mm thick
54 mm OD x 1.2 mm thick
42 mm OD x 1.2 mm thick
28 mm OD x 0.9 mm thick
22 mm OD x 0.9 mm thick
15 mm OD x 0.9 mm thick
12 mm OD x 1.0 mm thick
Zonal Valve Box with Ball Valve & Pressure Gauge.
6 Service (5 Gas+1 Vacuum)
2 gases (1 Gas+1 Vacuum)
Medical Gas Area Alarm - Touch screen min. 9 inches
6 Service (5 Gas+1 Vacuum)
2 gases (1 Gas+1 Vacuum)
Master Alarm with touch screen (Digital)
Isolation Valve
Bed Head Panel without Out - Let provision
2 GAS BHP OXY-1, & VAC-1, 900MM LONG as per Tender Spech.
HANDRAIL, CRASHRAIL AND CORNER GUARD
Providing and fixing 700 series superior impact resistance Wall Guard Vinyl (Lead Free) Snap on cover of .080" (2mm) thickness shall be extruded from chemical and stain resistant polyvinyl chloride with the addition of impact modifiers. No plasticizers shall be added (plasticizers may aid in bacterial growth) cis. Surface shall have a Pebblette texture for scratch resistannce and Continuous aluminum retainer of .080" (2mm) thickness shall be fabricated from 6063-T5/T6 aluminum, with a mill finish. Dimensions to be of 7 3/4" (197mm) height x 1" (25mm). Inner snap-on vinyl impact black bumper of .080" (2mm) thickness x 3.930" (100mm) width x 21mm height which shall be extruded from chemical and stain resistant unplasticized polyvinyl] chloride (uPVC). The system shall resist an Impact Strength of 45.5 ft-lbs/inch while producing no visual blemishes upon the vinyl cover surface and no deformations in the aluminum retainers, as tested in accordance with applicable provisions of ASTM F 476-84, paragraph 18, Impact Test and shall not support fungal or bacterial growth inaccordance with ASTM G-21 and G-22. The system shall also conform to class A fire rating and ASTM D-543 for chemical and stain resistance. It shall include standard quantity, as per manufacturer, of Molded End Returns.
Providing & Fixing 150 series high impact resistant surface mount Corner Guard having Vinyl Snap on cover (Lead Free) of .080" (2mm) thickness shall be extruded from chemical and stain resistant polyvinyl chloride with the addition of impact modifiers No plasticizers shall be added (plasticizers may aid in bacterial growth). Surface shall have a Pebblette texture for scratch resistance. Continuous Aluminum Retainer of .070" (1.8mm) thickness shall be fabricated from 6063-T5/T6 aluminum, with a mill finish. Dimensions to be of 3" (76mm) x 3" (76mm), 90 degree. The rigid vinyl profile shall resist an Impact Strength of 30.2 ftlbs/ inch as per ASTM D-256-90b and shall cis not support fungal or bacterial growth inaccordance with ASTM G-21 and G-22. The system shall also conform to class A fire rating and ASTM D-543 for chemical and stain resistance. It shall include standard quantity, as per manufacturer, of Molded Top / End Caps.
Providing and fixing 3110 series Handrail with integrated vinyl wall guard having Rigid Vinyl Snap-on cover (Lead Free) of .080" (2mm) thickness extruded from chemical and stain resistant unplasticized polyvinyl chloride (uPVC) with the addition of impact modifiers. No plasticizers shall be added (Plasticizers may aid in bacterial growth). Surface shall have a pebblette texture for scratch and stain resistant with rigid vinyl cover mounted on a sturdy continous Aluminium Retainer of .080" (2mm) thickness that shall be fabricated from 6063- T5/T6 Aluminium with a mill finsh. Dimesnions to be 6-1/8 " (155mm) height x 1-1/2" (38mm) full round gripping diameter, system extends 3-1/8" (79mm) from the wall. Integrated vinyl cover, 4" (101mm) high. Inner snap-on vinyl impact black bumper of .070" (1.8mm) thickness and 2-1/4" (57mm) high shall be extruded from chemical and stain resistant unplasticized polyvinyl] chloride (uPVC). The system shall resist an Impact strength of 45.5 ft-lbs/inch while producing no visual blemishes upon the vinyl cover surface and no deformations in the aluminum retainers, as tested in accordance with applicable provisions of ASTM F 476-84, paragraph 18, Impact Test cis. The rigid vinyl shall not support fungal or bacterial growth inaccordance with ASTM G-21 and G-22. The system shall also conform to class A fire rating and ASTM D-543 for chemical and stain resistance. It shall include standard quantity, as per manufacturer, of Molded Mounting Brackets / End Returns.
NURSE CALL SYSTEM
The system switch forms a decentralised communications node for exchanging data between the connected system devices and the rest of the communications system, consisting of : - 1 x RJ45 socket, 100Mb IP Port (IEEE802.3 100BaseTX), galvanically isolated conforming to EN 60950 and VDE 0834; - 7 x RJ45 sockets, each for a 100Mb IP system port (IEEE802.3 100BaseTX) for connecting all IP capable system modules; - 1 x RJ45 socket, 100Mb IP Port (IEEE802.3 100BaseTX) for connecting communications, staff and ward terminals as well as control panel PCs or for redundant Connection. - Control LEDs for indicating the current operating state; - 2 x RJ45 sockets for connection of the external data bus; - All IP system modules are supplied with power using Power over LAN technology;
VDE 0834 certified / approved Nurse Station Terminal
Nurse Station shall comprises of minimum 7“ large touch screen LC colour graphic display for displaying all details , a smash proof glass panel (to protect the sensitive display from unnecessary contact during cleaning and other processes) , Querying receiver for speaking discretely, Microphone and loudspeaker for hands-free speech (incl. volume control), automatic changeover between hands-free and discrete speaking , Electronic circuit board with controller and FlashProm, 100BaseTX interface to the system switch, PC interface to the communications control panel , 2.8m connection cable with an RJ45 connection plug, which is protected, from disconnection, for connecting to a connection module . The ward terminal shall display date and time, indication of all presence, all set reminedrs, indication of all calls in accordance with VDE0834. All call indications follow the priority and must display the exact location of the calls. The ward terminal shall be provided along with suitable connection module & back box
Nurse station with External monitor VDVI Module - DVI output to display nurse call on external monitor (Incase DVI input not available in external monitor, DVI to HDMI convertor may be used for HDMI output) External Monitor - To display call generation on external bigger display Min. 21" LCD/ LED monitor with mounting accessories having DVI/ HDMI port (Seven segment display is not accepted)
VDE 0834 certified/ approved Call & Cancel Button - For General IPD ward Call & Cancel button for general IPD wards: - 1 call button (Red) including a finder light & reassurance light, - 1 presence button (green) incl. control LED, - integrated finder lights or reassurance light - Moisture Protected - a membrane keypad - should be connected in loop technology.
Supply ,Installation ,Testing and commissioning of of VDE 0834 certified/ approved Patient Handset - Without Speech
consisting of a plastic case in antimicrobial finish having - Call button with nurse symbol with integrated finder and reassurance light on the top end of the unit, - Membrane keypad in antimicrobial/ anti fungal finish with integrated LEDS for operation, consisting of: - 2 call key, - 2 lighting keys - 2.80 metre connection cable with auto-disconnecting RJ45 connector plug. It shall be supplied with cradel for holding patient terminals & necessary connection module.
Supply ,Installation ,Testing and commissioning of of VDE 0834 certified/ approved connection module for Patient Terminal
Connection module for patient handset shall consist of: - 1 x RJ45 socket marked in colour and with measures to ensure that the push button is correctly connected, including auto disconnect mechanism, - 1 membrane keypad with: - 1 call button (red with nurse symbol) including a finder/reassurance light, - 1 presence key/ cancel button (green) including a control LED, - 1 DIN Socket for interfacing with other medical devices - should be connected in loop technology.
VDE 0834 certified/ approved Pull Cord with cancel Button for Bath area
Pull cord for WC shall consist of: - 1 call button (pull cord) including a finder light & reassurance light, - 1 presence button (green) incl. control LED, - integrated finder lights or reassurance light - micro switch with a 2 metre pull cord and a luminous grip with a nurse call symbol, Pull cord characteristics: max. force at break: 120N (ca. 12 kg): for hygiene reasons it must also be possible to change the pull cord very easily using a snap hook; - Moisture Protected - should be connected in loop technology.
VDE 0834 certified/ approved Code Blue button - Doctor call-Cancel button for wards
1 doctor call key (blue) including a finder light / reassurance light, - Doctor cancel button - a membrane keypad - Integrated sounder -2 RJ45 ports for loop connectivity - should be connected in loop technology.
Supply of VDE 0834 certified/ approved Loop Powered Lamp Module
For optical indication of calls, presences and reminders in the relevant colours consisting of: - 5 light chambers with light reflectors for homogeneous illumination, - 1 light chamber fitted with 3 ultra bright red LEDs, - 1 light chamber fitted with 3 ultra bright white LEDs, - 1 light chamber fitted with 3 ultra bright green LEDs, - 1 light chamber fitted with 3 ultra bright blue LEDs, - 1 light chamber fitted with 3 ultra bright Yellow LEDs, - 2 RJ45 ports for loop connectivity - the LED life expectancy is approximately 100,000 operating hours, - should be connected in loop technology.
Networking, Software & Integration
Supply of Management center - Nurse Call Server
Management Centre Server for Nurse Call System for uploading the firmware and the system configuration, for operating interfaces to foreign systems, for logging of all system events and as a central location for system configuration and remote maintenance as per VDE 0834 - Intel Xeon 3220 2,4GHz or similar - 2 GB RAM, 1 x 160GB HDD - 1 x DVD harddrive, 2 x Gbit LAN Ethernet RJ45 - 1 x serial connection RS232 and 2 x USBV2.0 - 1 x PCI or 1 x PICe socket, support for SUSE Linux enterprise Server from V10.1
Supply of Backbone Switch
Floor Switch: Uplink connections: 2 x 1Gb uplink ports, RJ45 (GBIC capable, possibility for LWL) Connections downlink: 24 x 100Mb downlink ports, RJ45 Switch must have all the Layer 2 and Layer 3 function which is mentioned.
Software- Event Database Software
Software pack installed on the system server for automatically logging all events in the entire communications system, such as, e.g., calls, presence markings, call acknowledgements, reminders.
BIOMEDICAL WASTE MICROWAVE SYSTEM
SITC of Waste Microwave Sterilizer of capacity per batch: 60 litres to 70 litres with standard accessories + Needle Destroyer as a whole Package along with turnkey/internal designing work required for installation & commissioning & other requirement for the operationalization of the Unit). Needle Destroyer: 4 Numbers. Puncture proof containers-3 Nos. Biological or Chemical indicator
SIGNAGE WORK
Providing and fixing Laser Cut Acrylic Letters with Stain less Steel sides along with Korean Led Lights, Letters will be directly fixed over the Main Facade. 6 Feet by 3 Feet
Providing and fixing Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back. 4 Inch18 Inch by
Providing and fixing Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required.2 Feet by 4 Feet
Providing and fixing Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required.4 Feet by 4 Feet
Providing and fixing Backlit Acrylic Box Lit with Korean Led.2 Feet by 1 Feet
Providing and fixing 3 mm Acrylic with Desired Color with Plotter Cut Vinyl Letters.6 Inch by 3 Inch
Providing and fixing Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required.4 Feet by 3 Feet
Providing and fixing Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required installed on Wall with Studs.4 Feet by 2 Feet
CSSD EQUIPMENT
SITC of Steam Sterilizer with pass through double door (1450 -1500 liters) :- The Steam Sterilizer with minimum 18 STU capacity with Internal Trolley - 02 Nos, External Trolleys - 2Nos & Stainless Steel Baskets - 18Nos. complete as per technical specifications attached with 15 inch touch screen and carbon fiber front from on top of SS panel.
SITC of Steam Sterilizer with pass through double door (850 -900 liters) :- The Steam Sterilizer with minimum 12 STU capacity with Internal Trolley - 02Nos, External Trolleys - 2Nos & Stainless Steel Baskets - 12Nos. complete as per technical specifications attached with 15 inch touch screen and carbon fiber front from on top of SS panel.
SITC of Low Temperature Steam Formaldehyde (LTSF) double door :- Low Temperature Steam Formaldehyde (400-450 liters) with 06 STU capacity with 1 No. Internal & 2Nos. External Trolleys & 06 Nos. Stainless Steel Baskets of 1 STU.
SITC of Double Door Washer/Disinfector with minimum 15 DIN :- Washer/Disinfector capacity including Surgical Instrument Trolley- 2Nos, External Trolley -2Nos. & 15Nos. 1DIN Trays The washer disinfector should be suitable for cleaning and disinfection of surgical instruments/goods. The process should include pre wash, detergent wash and hot water disinfection, rinse and drying cycles.
SITC of Ultrasonic cleaner bench top of capacity 45 Liters suitable for operation on 230V, 50 Hz AC Supply. The units should be a compact bench top model, with a built-in tank, manufactured from high-quality SS 304/316 stainless steel and a solid-state generator that sends ultrasonic (approx. 40 KHz) impulses through wash water containing detergent and electrical heating;
SITC of Tracking & Bar coding software : Software for tracing and monitoring with minimum touch screen of 21" inches connected to all sterilizer and washer + 3 computer of i7 intel windows based.
SITC of Heat Sealing machine:- Rotary heat sealers should provide validated sealing of sterilization bags and clear-view pouches (paper/plastic laminate). It should be microprocessor-controlled."
SITC of Air & Water Gun :- Spray gun rinse unit should be designed for connection to water or compressed air, to use for assisted cleaning of pipettes, catheters, cannulas, syringes etc."
SITC of ETO Machine 250 ltr.
Furniture for CSSD
SITC of Double door Drying Cabinet of capacity 280 Litres It Should be automatic in operation and Inner chamber should be made up of stainless steel and outer chamber should be of epoxy painted CRCA sheets.It Should have heaters of minimum 2 KW."
SITC of SS Washing Station with 2 sink
SITC of SS Control & Packing table
SITC of SS Linen Fold table
SITC of SS Storage Shelf
SITC of SS Pass Box
SITC of SS Closed Trolley for Sterile material transport
SITC of SS Working table
SITC of Basket Trolley suitable to accomdate basket complete with all accessories
SITC of SS Stool for operators
SITC of Change Locker - 4 compartments
SITC of Closed Sterilization Containers 300mm x 290mm x 110mm (+/-10%)
SITC of Closed Sterilization Containers 300mm x 290mm x 140mm(+/-10%)
SITC of Closed Sterilization Containers 590mm x 280mm x 260mm (+/- 10%)
SITC of Shoe Rack
SITC of Receiving Counter
SITC of Issue Counter
SITC of Waste Bin Pedal Operated - SS
SITC of Storage Cupboard
SITC of Inspection lamp with magnifier
SITC of SS Roll holder with cutting knife
SITC of Gauze cutting machine
SITC of Documentation Labeller
Providing & fixing of Office Table
Providing & fixing of Visitors Chair
KITCHEN EQUIPMENT
PLATEFORM TROLLEY Unit should be made of 16 swg SS construction. Handle frame to be made of 25 mm Ø round tubing. Under construction should be of SS angle frame work with 100 mm Ø, noise free rubber castors to be provided with 2 Nos. wheels should have a locking arrangement.1200X700X850
WEIGHT SCALE Unit should have SS Platform of size 900 x 900 mm with a digital instrument panel connected on a vertical stand.500Kgs
WORK TABLE WITH DRAWER The work top should be 16 swg SS SS welded to 38x38x 3mm SS angle frame supported. The legs should be made of 38mm dia 16 swg SS with adjustable S.S. bullet feet .1800X750X850+150
WEIGHT SCALE Unit should have SS Platform of size 900 x 900 mm with a digital instrument panel connected on a vertical stand.50Kgs
AIR CURTAIN Suitable for Door of Height: 1.8 Meter & Width: 1 Meter - MS power coated body - Velocity: 16 m/sec or more - With Infrared Sensors - With Door Magnetic Sensor - With Micro Switch - With Installation.1800mm LENGTH
WORK TABLE WITH UNDERSHELF The work top should be 16 swg S.S.and an under shelf of 18 swg SS 304 welded to 38 x 38 x 3mm SS angle frame supported. The legs should be made of 38mm dia 16 swg SS 304 with 4" Wheel.1500X750X850+150
VEGITABLE WASHER MACHINE Features: Dimensional accuracy Smooth surface finish Different shapes High functioning Sturdy construction.1500X900
WORK TABLE WITH UNDERSHELF The work top should be 16 swg SS and an under shelf of 18 swg S.S.welded to 38x 38 x 3mm SS angle frame supported. The legs should be made of 38mm dia 16 swg SS.with 4" Wheel.1500X750X850+150
HAND WASH SINK Top & Sink Bowl will be reinforced with SS under construction. Sink will be of 16 swg SS 304. Sink should be provided with CP 38 mm BSP Drain Coupling. Sink bowl size: 450 x 450 x 250 mm deep.350X350X250
ONION/POTTATO BIN The Top, Rear, Left, Right and Front should be of 18 swg MS Perforated Sheet, powder coated. Base should be made of 16 swg SS with stiffeners. The partition should also be perforated made of 18 swg MS. The lid should have extra strong hinges with a stopper and a strong latch, which also act as a handle. The unit should have a 18 swg S.S.sliding door with a SS rod handle. The unit should be fitted with heavy-duty GI castors of 150 mm Ø rubber wheels.900X750X900
HOSE REEL Open epoxy coated steel hose reel, high flow spray valve, 3/8" x 50' heavy duty non-marking hose, ratcheting system, multi- fit bracket, adjustable hose bumper and 3/8" NPT female inlet.90MTRS
STORAGE RACK Shelves should be made of 18 swg SS sheet. Each rack will have 4 shelves spaced equidistantly from each other and reinforced with 25 x 100 x 25 mm inverted 16 swg S.S.angle. The bottom shelf should be spaced at 150 mm above ground level. The shelves will be welded to SS uprights. Uprights will be made of 38 mm Ø x 16 swg SS.pipe / legs with adjustable bullet feet.900X450X1800
TEA SERVICE TROLLEY SS Construction 18 Swg. 18 Swg three side covering front door with handle &lockable U/S 18 Swg 100 mm Ø, noise free rubber castors to be provided with 2 Nos. wheels should have a locking arrangement.900X600X900
HOT FOOD SERVICE TROLLEY Top 16 Swg, SS outer pinling 20 swg and front door.Under shelf 18 Swg, SS tray slide angle 16 Swg 38x38mm with handle. Two side 25mm dia SS tube 4 side corner rubber safety guard with door locking system. Automatic heating control system with ON/OFF rocker switch. Electric load 1.5KW, 60mm thick Glass insulation. 6" dia wheel with two brake.700X600X1800
BUSSING TROLLEY Unit should be made of 18swg SS construction. Handle frame to be made of 25 mm Ø round tubing. angle frame work 38x38x3mm Under construction should be of SS frame work with 100 mm Ø, noise free rubber castors to be provided with 2 Nos. wheels should have a locking arrangement.1200X700X850
PLATEFORL TROLLEY Unit should be made of 14swg SS construction. Handle frame to be made of 25 mm Ø round tubing. angle frame work 40x40x5mm Under construction should be of SS frame work with 100 mm Ø, noise free rubber castors to be provided with 2 Nos. wheels should have a locking arrangement.1200X600X850
AIR CURTAIN Suitable for Door of Height: 1.9 Meter & Width: 1 Meter - MS power coated body - Velocity: 16 m/sec or more - With Infrared Sensors - With Door Magnetic Sensor - With Micro Switch - With Installation.1900mm LENGTH
STRIP CURTAIN Visible light quantity transmitted through the material. 80 Index based on a flat indenter's penetration depth. Scale from 0 (Soft) to 100 (Hard). 55 Minimum tensile stress required to tear a pre-slit sample. 18 Maximum tensile stress that a material can be subjected to before break. 300 Elongation of the specimen at the break point under tensile stress. 62 Permanent elongation of the specimen measured after rupture in a tensile test. Ability to conduct heat. The Lower it is, the more insulation. -25 Temperature at which the specimen break under torsion stress. Brittle point (CLASH & BERG). -15 +50 Temperature range where material keep its mechanical properties (flexibility). 50 Temperature at which the specimen is penetrated to a depth of 1 mm by a 1 kg flat indenter of 1 sq. mm. 1,6 Heat energy required to increase the temperature of one kilogram of the material by one degree Celsius. >35 Average sound level (freq. 0,1 to 3,2 kHz) decreased by a 1,76 sq.m. and 5 mm thick PVC curtain. EN 1598* Standard classification of material self-extinguishing and resistance to combustion. Filter* Ability to filter welding rays allowing the use of this material as a welding protection screen. High Ability to resist to UV (Sun, welding arc). Yes Earthed sample is rubbed with cotton, acrylic and nylon rubbers. At electrode approach, spark appears or doesn't. 4.1013 Material surface electric resistivity measured with a 500 V direct voltage. -o,2 Material mass variation after exposure to humid conditions. (<0 if released / >0 if absorbed) Special ability No Special ability to keep insects away.(Food processing plants, tropical regions) 1,22 to 1,33 Mass per unit volume.1900mm LENGTH
DISH SLIDING TABLE (CONVAYER TYPE) Top 16sg of Grade SS with Chute Legs ,welded to 38x 38x 3mm SS 202 angle frame supported made of 38 mm Ø x 16 swg SS pipe with adjustable nylon bullet feet.2650X900X850
SOILED DISH LANDING TABLE WITH GARBACE CHUTE & GLASS RACK SHELF Top 16sg S.S. Grade SS with Chute Legs ,welded to 38 x 38x 3mm SS angle frame supported made of 38 mm Ø x 16 swg SS pipe with adjustable nylon bullet feet.2300X900X850+150
DUST BIN S.S. construction 450mm round 4 castor wheels.ø450mm ROUNG
TWO SINK UNIT SS SGL Bowl Sink unit with splash.The work top should be SS 16 SWG and an under construction of the sink of 16 SWG S.S. reinforced & welded to 38x38x3mm SS angle frame supported on 16 SWG. The legs should be of 38mm dia with adjustable nylon bullet feet.1600X750X850+150
Pre-Rinse Unit with single hole deck mounting for hot or cold water supply and standard spray head SPECIFICATION EasyInstall Pre-Rinse unit with single hole deck mounting base for either hot or cold water supply. Fitted with ceramic cartridge mechanism with quarter turn operation. Manufactured in brass, with copper striking and high density chrome plate finish. Easy install ‘Pop and Lock’ assembly, with a lock washer to prevent the riser from rotating, variable rate steel spring and a reinforced inner hose with stainless steel flexible casing. Supplied with finger hook and 305mm wall bracket for extra stability. Rose pattern spray valve provides a flow rate of 5.375 litres/minute at 4bar pressure. A WRAS approved product.
CONVAYER TYPE DISH WASHING UNIT Theoretical capacity- racks/hr: 90 Theoretical capacity- plates/hr: 1620 Rack Dimensions: 500 X 500 mm Overall size: Door closed 1600X750X1575 mm Door open 1600X750X1900 mm Clear Entry Height: 400 mm Tank Heating: Cold Water Supply 9 KW Boiler Heating: Cold Water Supply 18 KW Total electrical load: Cold Water Supply 29 KW Wash: Wash Pump (HP)2.0 Tank Capacity100 L Tank temperature: 60C Boiler temperature: 82C Rinse water requirement at 3 bar pressure: 3 L/rack Automatic wash and rinse zone sensors in case racks are detected Rinse Aid Pump and Detergent Dosing pump included
VAPOUR HOOD Hoods are constructed of 18 gauge steel · Grease Filters are 20” baffle type which carry a U.L. listing and constructed of light Grease trough is made to receive grease extracted by the filter · Each Grease trough is equipped with a stainless steel cup · Notes: Factory does not cut holes in hood Hoods 10' and Larger Receive 6 Hanger Brackets Total.2400X900X500
CLEAN DISH LANDING TABLE Stainless Steel angles to be provided below the unit for sliding the empty dishwasher racks of size 500 x 500 x 100 mm. At the end the stopper should be provided to hold the basket in the tray rack. Other details as per general specifications.1800X750X850+150
CLEAN DISH RACK Drain S.S. GUAGE 16SG SHEET AND GRATING SS STRIP OF 25 MM X3MM.900X450X1800
HOSE REEL Open epoxy coated steel hose reel, high flow spray valve, 3/8" x 50' heavy duty non-marking hose, ratcheting system, multi- fit bracket, adjustable hose bumper and 3/8" NPT female inlet.90MTRS
WORK TABLE WITH 2UNDERSHELF The work top should be 16 swg S.S.and an under shelf of 18 swg SS 304 welded to 38x 38x 3mm S.S.angle frame supported. The legs should be made of 38mm dia 16 swg SS with 4" Wheel.1800X700X850+150
WORK TABLE WITH 2SINK UNIT Top & Sink Bowl will be reinforced with SS under construction. Sink will be on the Right Hand Side made of 16 swg S.S. Sink should be provided with CP 38 mm BSP Drain Coupling. Sink bowl size: 450 x 450 x 250 mm deep.1800X700X850+150
MOCROWAVE OVEN Function: Grill Capacity (Litre): 20 Cavity Type: Powder Coated Control Type: Mechanical Microwave Power Levels: 4 Led Display: Yes Features: 360 Degree Clean, Auto Defrost, Child Lock, Cooking Completion Indicator, Smartwave Technology, Tandoori Heater Voltage (Watts): 700 Warranty: 3 Year(s) Color: White Dimensions: 335x452x425
INDUCTION PLATE Materials of main body:Mircro crystal plate Height :65 mm Width :291 mm Depth: 366 mm Color(s):BlackTechnical specifications Voltage :220-240 V Frequency:-50 Hz Wattage :2100 W Fast cooking better seals nutrition into food Auto-off program cooks food safely More comfortable cooking without flame Cool-to-touch surface cooks foods safely
COFFEE MACHINE Dimension (Inches) (W x D x H) : 20 x 24 x 20 Capacity Espresso Coffee/Hr : 240 Power : 230V 1ph Wattage : 2850 Number of Boilers/Capacity : 6 lts x 1 Key Features:- Equipped with microprocessor to control the Coffee Dosages Volumetrically Group Auto Cleaning 4 Different Dosage Setting per group Boiler's Auto Refill
FOUR DOOR VERTICAL REFRIGERATOER Unit shall be of full SS construction with interior and the exterior of 20 swg S.S.The inner wall will be suitably insulated with 65 mm thick PUF. It have 2 doors, constructed of 18 swg S.S. . It should be fitted with digital temperature indicator, control switches and indicator lights. An Isolator switch on the front panel near digital thermometer to be provided for On - Off of the refrigerator. The equipment should be able to maintain a temperature range of +2°C to +8°C. The unit shall be provided with a removable SS drip tray below. The compressor unit will be top mounted and should be of a reputed make from Kirloskar / Techmshah. Legs should be made of 50 mm Ø x 16 swg S.S. pipe with adjustable nylon bullet feet at 150 mm above finished floor level. The refrigerator will have a forced draft type cooling.1350X800X2100
CHEST FREEZER .150LTRS
STORAGE RACK. 900X550X1800
HOT PLATE WITH HALF RIBBED.1200X700X850+150
WORK TABLE WITH 2UNDERSHELF he work top should be 16 swg SS. and an under shelf of 18 swg SS welded to 38x38x3 mm SS angle frame supported. The legs should be made of 38mm dia 16 swg SS with 4" Wheel.650X700X850+150.
THREE BURNER RANGE consisting of SS framework. The top sheet will be of 16 swg SS . Rear & both sides will be of 20 swg SS and provided with cross support of 25 mm Ø x 16 swg SS pipe. The front and control panel will be of 18 swg SS . It will be provided with 3 No. heavy-duty cast iron vessel rests and 3 No. high-pressure burners rated at 72,000 BTUs per hour with individual 3 No. pilot and needle control knob. 3 No. of removable drip trays to be provided. Legs should be made of 40 mm Ø x 16 swg SS pipe with adjustable nylon bullet feet.1800X700X850+150
SINK TABLE Top & Sink Bowl will be reinforced with SS under construction. Sink will be on the Right Hand Side made of 16 swg SS Sink should be provided with CP 38 mm BSP Drain Coupling. Sink bowl size: 450 x 450 x 250 mm deep.650X700X850+150
EXHAUST HOOD WITH S.S. FILTER Hoods are constructed of 18 gauge steel · Grease Filters are 20” baffle type which carry a U.L. listing and constructed of light Grease trough is made to receive grease extracted by the filter · Each Grease trough is equipped with a stainless steel cup · Notes: Factory does not cut holes in hood Hoods 10' and Larger Receive 6 Hanger Brackets Total.7550X900X500
WORK TABLE WITH 2UNDERSHELF he work top should be 16 swg SS and an under shelf of 18 swg SS welded to 38x38x3mm SS 202 angle frame supported. The legs should be made of 38mm dia 16 swg SS with 4" Wheel.1950X700X850+150
THREE DOOR UNDERCOUNTER REFRIGERATOR.1700X700X850+150
WORK TABLE WITH UNDERSHELF The work top should be 16 swg SS and an under shelf of 18 swg SS welded to 38x38x 3mm SS 202 angle frame supported. The legs should be made of 38mm dia 16 swg SS with 4" Wheel.500X700X850+150
HOT BAIN MARIE The tank of the Bain Maire will be provided with an on-line connection with a ball valve of 15mm Ø and a drain valve of 15mm Ø to be provided. . Unit will have 3 kw water immerse heater with rotary On-OFF switch, indicating lamps and imported Thermostat of JUMO or EGO.1800X700X850+150
WORK TABLE WITH SINK Top & Sink Bowl will be reinforced with SS under construction. Sink will be on the Right Hand Side made of 16 swg SS Sink should be provided with CP 38 mm BSP Drain Coupling. Sink bowl size: 450 x 450 x 250 mm deep.1800X700X850+150
WORK TABLE WITH UNDERSHELF The work top should be 16 swg SS and an under shelf of 18 swg SS welded to 38x 38 x 3mm SS angle frame supported. The legs should be made of 38mm dia 16 swg SS with 4" Wheel.1800X700X850+150
GN PAN TROLLEY.650X700X1800
PACKING MACHINE
CHAPATI MACHINE(FULLY AUTOMATIC) This will be an Electrical & Gas operated machine. The machine should have a capacity to produce 1000 Chapatti per hour. The machine should have two seprate plate with a different speed with a round Gas burner with it's control valve & pilot. There should be one or two seprate burners for puffing Chapatti.The machine should have a digital temprature indicatior for both the plate. The control knob panel should be at the top right side. The unit should have removable panel from all side. The dough pressing plate sould have a heating element fixed on it with Thermostat to maintain the correct temprature. The machine sould have a dischage lip from where cooked Chapatti will come out. The electrical motor & it's other componant should be properly coverd & should have prevention from heat. The operating voltage should be 3~N415V. This should be as supplied as Neo Concept, 2400X900
EXHAUST HOOD are constructed of 18 gauge steel · Grease Filters are 20” baffle type which carry a U.L. listing and constructed of light Grease trough is made to receive grease extracted by the filter · Each Grease trough is equipped with a stainless steel cup · Notes: Factory does not cut holes in hood Hoods 10' and Larger Receive 6 Hanger Brackets Total.2850X1200X500
CHAPATTI TROLLEY.600X600X850
WORK TABLE WITH SINK Top & Sink Bowl will be reinforced with SS under construction. Sink will be on the Right Hand Side made of 16 swg SS Sink should be provided with CP 38 mm BSP Drain Coupling. Sink bowl size: 450 x 450 x 250 mm deep.1900X750X850+150
DOUGH KNEADER Round Drum : SS. Thickness of the sheet : 16 G.A. Body : Cast Iron 2 Hp Chrompton Motor 30KGS
WORK TABLE WITH SINK Top & Sink Bowl will be reinforced with SS under construction. Sink will be on the Right Hand Side made of 16 swg SS Sink should be provided with CP 38 mm BSP Drain Coupling. Sink bowl size: 450 x 450 x 250 mm deep.1750X750X850+150
AATA/MAIDA BIN.450X600X700
FOUR DOOR VERTICAL REF. Unit shall be of full SS construction with interior and the exterior of 20 swg SS The inner wall will be suitably insulated with 65 mm thick PUF. It have 2 doors, constructed of 18 swg SS . . It should be fitted with digital temperature indicator, control switches and indicator lights. An Isolator switch on the front panel near digital thermometer to be provided for On - Off of the refrigerator. The equipment should be able to maintain a temperature range of +2°C to +8°C. The unit shall be provided with a removable SS drip tray below. The compressor unit will be top mounted and should be of a reputed make from Kirloskar / Techmshah. Legs should be made of 50 mm Ø x 16 swg SS 304 pipe with adjustable nylon bullet feet at 150 mm above finished floor level. The refrigerator will have a forced draft type cooling.1500X750X2100
STAND FOR COMBI OVEN.1800X900X700
COMBI OVEN.10GN
EXHAUST HOOD WITH S.S, FILTERS Hoods are constructed of 18 gauge steel · Grease Filters are 20” baffle type which carry a U.L. listing and constructed of light Grease trough is made to receive grease extracted by the filter · Each Grease trough is equipped with a stainless steel cup · Notes: Factory does not cut holes in hood Hoods 10' and Larger Receive 6 Hanger Brackets Total.7500X1200X500
3 DOOR UNDERCOUNTER REFRIGERATER Inner & Outer Body:- 22 SWG Top made by :- 18 SWG rame work:- MS Angle 38x38x3mm Compressor:- Emmersion Tem:- -+0 to +4 Deg C.1700X700X850+150
SINK TABLE Top & Sink Bowl will be reinforced with SS under construction. Sink will be on the Right Hand Side made of 16 swg SS Sink should be provided with CP 38 mm BSP Drain Coupling. Sink bowl size: 450 x 450 x 250 mm deep.750X700X850+150
WORK TABLE The work top should be 16 swg SS an welded to 38x 38x 3mm SS angle frame supported. The legs should be made of 38mm dia 16 swg SS with 4" Wheel.800X700X600
STOCK POT RANGE consisting of SS framework. The top sheet will be of 16 swg SS Rear & both sides will be of 20 swg SS and provided with cross support of 25 mm Ø x 16 swg SS 304 pipe. The front and control panel will be of 18 swg SS . It will be provided with 1 No. heavy-duty cast iron vessel rests and 1 No. high-pressure burners rated at 72,000 BTUs per hour with individual 1 No. pilot and needle control knob. 1 No. of removable drip trays to be provided. Legs should be made of 40 mm Ø x 16 swg SS pipe with adjustable nylon bullet feet.700X700X600
EXHAUST HOOD WITH S.S. FILTER Hoods are constructed of 18 gauge steel · Grease Filters are 20” baffle type which carry a U.L. listing and constructed of light Grease trough is made to receive grease extracted by the filter · Each Grease trough is equipped with a stainless steel cup · Notes: Factory does not cut holes in hood Hoods 10' and Larger Receive 6 Hanger Brackets Total.7600X900X500
3DOOR UNDERCOUNTER REFRIGERATER Inner & Outer Body:- 22 SWG Top made by :- 18 SWG rame work:- MS Angle 38x38x3mm Compressor:- Emmersion Tem:- -0 to 4 Deg C.1700X700X850
TILTING BRATT PAN.100LTRS
TILTING RICE BOILER.100LTRS
EXHAUST HOOD WITH S.S. FILTER Hoods are constructed of 18 gauge steel · Grease Filters are 20” baffle type which carry a U.L. listing and constructed of light Grease trough is made to receive grease extracted by the filter · Each Grease trough is equipped with a stainless steel cup · Notes: Factory does not cut holes in hood Hoods 10' and Larger Receive 6 Hanger Brackets Total.7500X1200X500
POTATO PEELER The Top, Rear, Left, Right and Front should be of 18 swg MS Perforated Sheet, powder coated. Base should be made of 16 swg SS with stiffeners. The partition should also be perforated made of 18 swg MS. The lid should have extra strong hinges with a stopper and a strong latch, which also act as a handle. The unit should have a 18 swg SS 304 sliding door with a SS rod handle. The unit should be fitted with heavy-duty GI castors of 150 mm Ø rubber wheels.15KGS
MASALA GRINDER 1 HP Motor (Crompton)30KGS
WORK TABLE WITH SINK Top & Sink Bowl will be reinforced with SS under construction. Sink will be on the Right Hand Side made of 16 swg SS Sink should be provided with CP 38 mm BSP Drain Coupling. Sink bowl size: 450 x 450 x 250 mm deep.1700X650X850+150
WORK TABLE WITH 2UNDERSHELF The work top should be 16 swg SS and an under shelf of 18 swg SS welded to 38x38x3mm SS angle frame supported. The legs should be made of 38mm dia 16 swg SS 304 with 4" Wheel.1600X650X850+150
PULVERISER Side covering 22 swg ss sheet, ss pipe 1.25" with adjustable with nylone bullet feet. 2 HP crompton motor 15Kgs
ONION/POTATO BIN he Top, Rear, Left, Right and Front should be of SSwire Rod Sheet, d. Base should be made of 16 swg SS with stiffeners.900X750X900
TWO SINK UNIT WITH THREE SIDE CROSS BRESING SS SGL Bowl Sink unit with splash.The work top should be SS 16 SWG and an under construction of the sink of 16 SWG SS reinforced & welded to 38x38x3mm SS angle frame supported on 16 SWG. The legs should be of 38mm dia with adjustable SS bullet feet.1800X700X850+150
DIST BIN S.S. construction 450mm round 4 castor wheels.ø450mm ROUND
CHOPPINK BLOCK (GREEN) Chopping Board stand made of 38 mm Ø x 16 swg SS pipe / legs with adjustable nylon bullet feet. The top frame will be made of 30 mm square pipe of 16 swg SS with proper support & cross bracing. The unit will have a top of 40 mm removable Teflon board, which willbe inserted and can be removed easily for cleaning work in the top frame. An arrangement to keep the knives to be made.700X700X850+150
WORK TABLE WITH 3SIDE CROSS BRASING.1800X700X850+150
MOBILE CHOPPING BOARD SANITZER TROLLEY Chopping Board stand made of 38 mm Ø x 16 swg SS pipe / legs with adjustable nylon bullet feet. The top frame will be made of 30 mm square pipe of 16 swg SS with proper support & cross bracing. The unit will have a top of 40 mm removable Teflon board, which willbe inserted and can be removed easily for cleaning work in the top frame. An arrangement to keep the knives to be made.600X600X600
VEGITABLE CUTTING MACHINE MAKE : SIRMAN, ITALY POWER WATT : 515-Hp 0.7 POWER SOURCE : 230-400V/50HZ DISC REVOLUTIONS : RPM 300 NET WEIGHT 18.5KG GROSS WEIGHT : 22KG
DRAIN TROUGH GRATING Unit constructed of 14/304 stainless steel all-welded construction. Drain pan has built-in pitch towards drain, accommodates up to a 4˝-diameter pipe, and comes standard with a stainless steel removable perforated basket. Type 304 stainless steel subway style grating shall be 3 ⁄16˝ x 1˝ vertically positioned bars spaced 1˝ apart for ease of drainage. Two 5 ⁄8˝ stainless steel rods, set 21 ⁄4˝ in from each edge, are welded to the bars to eliminate swaying. 900X300X100
PACKING MACHINE
WORK TABLE WITH UNDERSHELF The work top should be 16 swg SS and an under shelf of 18 swg SS welded to 38 x 38 x 3mm SS angle frame supported. The legs should be made of 38mm dia 16 swg SS with 4" Wheel.1500X700X850+150
COLD ROOM.6600X3450X2400
S.S. STORAGE RACK Shelves should be made of 18 swg SS sheet. Each rack will have 4 shelves spaced equidistantly from each other and reinforced with 25 x 100 x 25 mm inverted 16 swg SS angle. The bottom shelf should be spaced at 150 mm above ground level. The shelves will be welded to SS uprights. Uprights will be made of 38 mm Ø x 16 swg SS pipe / legs with adjustable bullet feet.900X450X1800
WORK TABLE WITH UNDERSHELF The work top should be 16 swg SS and an under shelf of 18 swg SS welded to 38x38x 3mm SS angle frame supported. The legs should be made of 38mm dia 16 swg SS with 4" Wheel.1400x700x850+150
VEG. SLICER
INSECT KILLER
KNIFE STANISER
TWO SINK UNIT SS SGL Bowl Sink unit with splash.The work top should be SS 16 SWG and an under construction of the sink of 16 SWG SS reinforced & welded to 38x38x3mm SS angle frame supported on 16 SWG. The legs should be of 38mm dia with adjustable bullet feet.1800X700X850+150
CHOPPING BLOCK (RED) Chopping Board stand made of 38 mm Ø x 16 swg SS pipe / legs with adjustable nylon bullet feet. The top frame will be made of 30 mm square pipe of 16 swg SS with proper support & cross bracing. The unit will have a top of 40 mm removable Teflon board, which willbe inserted and can be removed easily for cleaning work in the top frame. An arrangement to keep the knives to be made.700X700X850+150
DUST BIN S.S. construction 450mm round 4 castor wheels.ø450mm ROUND
WORK TABLE WITH UNDERSHELF The work top should be 16 swg SS and an under shelf of 18 swg SS welded to 38 x 38 x 3mm SS angle frame supported. The legs should be made of 38mm dia 16 swg SS with 4" Wheel.1600X700X850+150
MOBILE CHOPPING BOARD SANITZER TROLLEY Chopping Board stand made of 38 mm Ø x 16 swg SS pipe / legs with adjustable nylon bullet feet. The top frame will be made of 30 mm square pipe of 16 swg SS with proper support & cross bracing. The unit will have a top of 40 mm removable Teflon board, which willbe inserted and can be removed easily for cleaning work in the top frame. An arrangement to keep the knives to be made.600X600X600
MEAT MINCER POWER : 735watt CAPACITY: 120 kg/h POWER SOURCE : 230-400V/50HZ STANDARD PLATE : 4.5mm OUTPUT/h : 150KGS./H NET WEIGHT: 18KGS. GROSS WEIGHT: 20KGS. DIMENSION-320X460X470
MEAT SLICER
PACKING MACHINE
DEEP FREEZER Unit should be made from 60 mm thick prefab rigid PUF sandwich panels with 0.60 mm thick pre-coated G.I.sheet outside and inside 0.50 mm thick SShaving a density of 40 kg/m3. The flooring to be of kotah flooring. The cold room should be with ceiling and wall panels interlocked through a cam lock mechanism. The Condensing unit should be fitted with a hermetic compressor (Kirloskar /Techmshah or equivalent). The condensing unit should be Unitary type & air cooled. The unit should be supplied with a swing type and flush type large insulated door having magnetic gasket, safety latch, lock and heavy duty hinges. The room should maintain a temperature of +2°C to +8°C. An emergency switch for alarm which will be fitted out side should be provided from inside the cold room in case of emergency / accidents. All accessories like light, light switch, temperature indicator should be provided with the unit. 3685X3455X2400
S.S. STORAGE RACK Shelves should be made of 18 swg SS sheet. Each rack will have 4 shelves spaced equidistantly from each other and reinforced with 25 x 100 x 25 mm inverted 16 swg SS angle. The bottom shelf should be spaced at 150 mm above ground level. The shelves will be welded to SS uprights. Uprights will be made of 38 mm Ø x 16 swg SS pipe / legs with adjustable bullet feet.900X450X1800
STRIP CURTAIN.1800mm LENGTH
KNIFE STANISER
POT RACK Unit to be provided with three (3) shelves, starting at 150 mm and then at equidistant, The uprights should be made of 32 mm dia SWG 16 SS pipe. The top sides of the uprights should be sealed and properly rounded. Shelves should be constructed with 25 mm dia SS pipe of 16 SwG.with internal grid of 19 mm dia SS pipe at 100 mm spacing. Four numbers, 38 mm SWG 16 SS tubular legs with adjustable bullet feet.1200X600X1500
MODULAR OPERATION THEATRES
Providing and installing Walls & ceiling panels, constructed with 0.8 mm Stainless steel 304 grade PUF Panels with tongue and groove mechanism for jointing and minimum width of 1200mm. The puff panel shall be made by injecting high pressure polyurethane foam with minimum density 40 kg/m3. The thickness of wall panels shall be 50 mm thick and ceiling panel shall be 30 mm thick. The inner surface walls will be fixed to the bricks wall with essential supports. The individual wall panels will not be spot welded together so as to ease removal for maintenance at a later date. All joints will be filled with metal filler and sanded flush on site ready to receive the plastic finish.
Providing and applying Antibacterial Paint: The internal surfaces of the room walls will be sprayed with water based liquid plastic, wall glaze or equivalent anti-bacterial paint, approved by the architect to a minimum dry film thickness of 300 microns. The plastic coating will overlap the floor covering ceiling system and doorframes by 25mm to provide a continuous sealed surface. The plastic coating will be non- reflective and the Colour will be submitted to the architect for approval.
Supply Installation, Testing & Commissioning of Ceiling filtration system 2400x2400mm: The ceiling filtration system shall be 2.40 meters x 2.40 meters and will be integrated with the adjacent false ceiling. The ceiling shall be constructed with a plenum box supplied with conditioned air from the central system via 8 nos. HEPA filters (European Norm EN 1822:2009; Class H 14; DOP 99.97-99.9999% efficiency for 0.3 micron particles) with pressure drop of 300 Pascal’s at its nominal flow rates (supplied with the Plenum), mounted on the exit from the supply ducting.
Supply Installation, Testing & Commissioning of Operation theatre flooring (antistatic conductive) : 2 mm Full Body Conductive Vinyl, laid on a semiconductive adhesive base. The floor finish should terminate at the room perimeter passing over a concealed cove former and continuing up the wall for 100mm. All joints should be welded with electrodes of the same compatible material to provide a continuous sealed surface
Fabrication, Supply, installation, testing & commissioning of sliding type Hermetically Sealed OT door having high density particle board cores, high pressure laminate face on both sides, viewing window 300 x 300mm. Size: 1500 x 2100 mm (W x H). Automatic Doors: Provided with Radar Switch - 2 Nos., Foot Switch - 2 Nos. and Photocell Sensors (Anti Crush Feature) & as per tech. specs. attached. Automatic Door (1500 mm x 2100 mm)
Supply, installation, testing & commissioning of Operation theatre control panel touch type full HD resistive 32 inches or more with:
· Time Day Clock
· Time Elapse Clock
· General and RGB Lighting System control (Peripheral Lights and plenum lights with dimming)
· Medical Gas Alarm Panel 5 Gas – low, normal and high pressure with sequencing as per HTM 02 01
· Hand Free Telephone set with speaker
· Temperature & humidity indicator with controller
· HEPA Filter Status module
· Room Pressure Indicator / differential pressure indicator
· USB Stick port
Supply, installation, testing & commissioning of Twin Plate LED X ray viewing screen: Size: 940 x 640 x 50 mm approx. with viewing area, Two plate X-ray view screen (120 W), LED based technology with colour temperature > 6000K and lamp life >50,000 hrs and brightness in excess of 4000 lux.
Supplying & fixing of sturdy writing Operating list board: made of ceramic surface having Magnetic properties and should be flushed to the wall of the operating room. Size 940mmx640mmx50mm
Supply, installation, testing & commissioning of SS Fabricated Cascade Pressure relief dampers: Suitably sized air pressure relief damper should be placed enabling differential room pressure to be maintained. Counter- weight balancing system should be provided in the PRD to maintain positive pressure inside the operation room.
Supply Installation and Commissioning of 42W Bottom Opening Room fixture with IP 65, Led make should be Nichia /Seoul < 5 SDCM , Own make BIS certified Islocated Driver , Flicker Free , Class 2 SELV driver, Operating temperature: -10°C to +45°C, Operating voltage range: 140-270V, Surge protection >3.5 KV, High Efficiency driver: 80-85% ,Low Voltage Cut Off below 130V, Output short circuit protection , Fixture Made up of MS powder coated white after phosphochromate treatment provided as standard with sheet thickness of 1.2MM, Diffuser of High impact polycarbonate opal diffuser with thickness 1.5MM for glare free uniform light distribution, power coating : 60 Microns , Lamp Source :High efficiency long life LED package in integral module with lumen efficacy of >140 lm/W and viewing angle of 120° to ensure better uniformity,Average life L70B50: 50000 hours, THD<10%, PF>.95, System efficacy >95-100 Lm/W, CRI>80 ,IP65, IK05 Impact rating, . Dimension Will Be 1240X330X115mm, Safety test as per IS:15885 Part 2/Sec 13.
Providing & fixing of Ceiling mounted double arm pendant systems for surgeon: The Weight carrying capacity of the arm should not be less than 180 Kgs load. There should be 5 or 6 nos. equipment loading shelves. double column of 1500mm. Double Arm Pivot range minimum 900mm and 300mm or above. The brake (Electromagnetic) supplied with Indian Origin Multipin 6/16amp electrical switch + socket – 10 nos., It should have 2 no. RJ 45 data socket. It should have provision for 06 gas outlet points
· 1 Oxygen,
· 2 Vacuum
Capable of 340 degrees of rotation. Medical gas terminal units shall be provided by the MGPS vendor and shall be installed in the pendant.USFDA
Ceiling mounted rigid pendant systems for anaesthesia: Double Arm motorized type pendants Made of Aluminum, powder coate with electromagnetic Brakes Swivel angle 0-330 degree
Dimensions: Double Vertical column 1200 mm
Vertical lift: 600 mm Horizontal arms – total 1800 mm (900 mm+900mm or 1000mm+800mm+800mm +1000mm) Pendant should be prepiped Provided with 10 nos medical gas outlets. Outlets shall be connected to dual circuit being provisioned for all Oxygen 2 outlets Nitrous Oxide 2 outlets Vacuum 2 outlets Medical Air 2 outlets AGSS 2 outlet colour coded high pressure tubing for each gas with NIST connectors at ceiling Provided with prewired 10 nos 6 / 16 amps sockets and two data sockets RJ 45
Instrument loading capacity 180 kgs. Shelves:
Two with handle and two rails each with capacity of 40 kgs Drawers one with handle and two rails
load capacity 40 kgs Swiveling stainless steel vertical pole
Supplying, Installation, Testing & Commissioning of floor mounted, Scrub station: Compact surgical 2 bay scrub sink designed for use in OT complex. Each fixture fabricated from heavy gauge 1 mm thick type 304 stainless steel of seamless welded construction, polished to a smooth finish with a front access panel which should be easily removed for access to the water controlled value, waste connections, stoppers and strainers. Hands free operation should include infra-red sensors with built-in range of adjustment. Thermostatic mixing, valve control should be located behind the access panel and maintain constant water temperature. User defined setting of approximately 1 to 3 min should be available.(Size: 1500mm X 675mm X 1105mm for 2 persons)
Supply, Installation, Testing and commissioning of ELECTRICAL CONDUITING WIth ELECTRICAL D.B AND WIRRING INSIDE OT . All wires should run within PVC conduits of 25mm size . Electrical distribution board complete with all accessories. Internal wiring with FRLS wires of reputed brands such as Bonton /finolex etc ,Wires will be of size 2.5Sqmm,4sq.and 6sqmm..Electrical Switchsockets of 6/16amp of approved make min 4 nos on each walls.
Providing and Fixing View window: Double insulated fixed glazing with not less than 5mm thick toughened glass. Window frame shall be powdered coated Aluminium of approved shape flush mounted with wall paneling Motorized horizontal Venetian Blinds of powder coated Aluminium strips of Vista level or equivalent of approved shade including necessary accessories. The motor shall be of reputed brand. The Venetian blinds should be motorized for 90 degree rotation and up and down movement. Size 1000x1000 mm
Storage unit: 1 mm thick Stainless Steel sheet 304. The storage unit should be divided 4 equal parts and each part should have individual swing 8 mm toughened glass doors with high quality stainless steel self-closing hinges capable of 180 degree swing out and secure locking system. Each part will be provided with removable stainless steel racks made from ½” circular (outer diameter) seamless Stainless Steel 304 tubes of 1 mm thickness placed at intervals of 1.5” center to center. The overall dimension of the storage unit shall be 1500mm (Width) x 2100mm (Height), 350mm depth being variable to suit architectural layout.
SITC of LED operating light having following specifications:- Maximum luminance (1m): 160,000 + 160,000 Lux at 1m distance, Electrical power: 150 + 90 W, Power consumption: 2x 11 A, Fitting: Ceiling anchoring ring ceiling pendant with 2 brackets and 2 spring arms, Range of movement: 1x 360° / 1x 330°, Recommended room height: at least 2.45 m, Max. ceiling load: 2x 218 Nm / 650 N, Light body weight: 9.2 + 7.5Kgs, Light body depth: 1x 130 cm / 1x 140 cm, Air shielding surface: 2 x 330 cm2 Transformers: 2x 450VA/230V/26V, Brightness regulator: 2x 20 – 500 VA (primary voltage), Provided with 2 Sterilisable handles with each dome, Easy positioning by sterilisable handle, Focus adjustable by sterilisable handle, Life time of Bulbs : 50,000 hours
Supply Installation, Testing & Commissioning of Medical Isolation Panel (20 KVA): Medical Isolation Panel should have digital output It should be specific for the supply of electrical systems in medical areas, in accordance with the regulation CEI 64-8 to guarantee total protection from macro and micro shock through electrical segregation between user and electric supply circuit. Medical Isolation Panels should have electrical features for use in medical spaces in accordance with the regulations:
· CEI 64-8/7 CAP.710
· CEI EN 61558-2-15
Capacity: 20 kVA, (10 kVA + 10 kVA), 6 line MCB + 6 line MCB (12 MCB). One for each OT.
SITC of True online double conversion Sinewave IGBT based rectifier and inverter 2 nos of 120 KVA Modular UPS connected in dual bus N + N configuration with the modules sized <10 kVA ( minimum 10 modules to be provided ) at unity PF ( KVA = KW ) 3 phase (415 V + 15% & -20%) Volts input & 3 phase output (415 V + 1%), 50 Hz, Input harmonic Current THD < 3% typical at 100% load at the input side , automatic bypass both static and electromechanical , with manual bypass , minimum 3 nos of control switch in the UPS,UPS efficiency upto 99% , complete in all respect including supporting steel structure for UPS i/c suitable rating single core copper conductor cable connecting UPS to batteries and transformer & as per specification etc as required. I/C ,S/I/T/C of Batteries for providing 30 minutes back up
For 100 KVA UPS . minimum 90720 VAH to be provided for each UPS along with suitable rack, cable and supporting steel structure for Battery cabinet complete & as per specification etc as required.
LAUNDRY EQUIPMENT
Supply Installation, Testing and Commissioning of Industrial Drying Tumbler. Front Loading Open Pocket, Reversible, Steam Heated 60 KG Capacity, Automatic Cool Down Feature.60 kg Capacity, Steam Heated.
Supply Installation, Testing and Commissioning of Flat Bed Press. Pneumatic, Automatic, Steam heated. Automatic digital timed. Powerful moisture suction blower. Pneumatic raising & lowering of spring suspended & Teflon lined Head. Adjustable ironing pressure. Head Size : 1500 x 750
Supply Installation, Testing and Commissioning of Flat Work Drying Ironer. 1 Roll. Heated Chest Type, Front Feed, Rear Return,Steam Heated,
Supply Installation, Testing and Commissioning of Washroom Trolley. S.S. 100 kg capacity , Overall Size : 1250 x 675 x 780 ht.
Supply Installation, Testing and Commissioning of Dry Linen Trolley. S.S. 50 kg capacity , Overall Size : 1100 x 600 x 1500 ht.
Supply Installation, Testing and Commissioning of Shelf Trolley. S.S. 100 kg capacity Overall Size : 1200 x 600 x 1700 ht.
Supply Installation, Testing and Commissioning of Mobile Table. S.S. Top Size : 1150 x 750
Supply Installation, Testing and Commissioning of Laundry Scrub Station with 2 Sinks. All S.S. Size: 1600 x 550 x 900 height.
Supply Installation, Testing and Commissioning of Vacuum Finishing Table. Table Size : 1200 x 750, Electric Steam Iron, Teflon shoe, aluminium armoured & Spring loaded Condensate separator.
Supply Installation, Testing and Commissioning of Industrial Washer Extractor. 30 kg Capacity High Spin, Suspended.Computer Controlled, steam heated.
Supply Installation, Testing and Commissioning of Industrial Washer Extractor. 60 kg Capacity High Spin, Suspended. Computer Controlled, steam heated.
Supply Installation, Testing and Commissioning of Mobile Table - S.S.Top Size : 2350 x 750
Supply Installation, Testing and Commissioning of Air Compressor, 3 HP Double Stage, 160 ltrs Tank
Supply Installation, Testing and Commissioning of Steam Boiler, 500 kg Capacity with Water Softener
Pneumatic Tube System (PTS)
Supply, Installation, Testing and Commissioning of Main Control & Linux Software System.
Supply, Installation, Testing and Commissioning of NW 160 mm Top load station Pass with RFID Reader Card.
Supply, Installation, Testing and Commissioning of NW 160 mm Multi Send Station Pass with RFID Reader Card.
Supply, Installation, Testing and Commissioning of NW 160 mm Multi Received Station Pass with RFID Reader Card.
Supplying, installation, testing & commissioning of Rotary Transfer Unit - 160 mm 1. Compact Rotary Transfer Unit 2. Should be able to connect 10 lines (for future expansion) without the need of a diverter. 3. carrier holders shuould rotate clock wise and anticlockwise in a circular movement to transfer carriers from one line to another. 4. should have minimum 24 empty carrier holding dedicated space to hold emergency carriers at all given times.
Supply, Installation, Testing and Commissioning of Diverter 160 mm, 3-Way, Air Tight, Microprocessor Controlled, With Touch Free Position and Tube Switches, Steel Housing. Provided with Optical Sensors.
Supply, Installation, Testing and Commissioning of Blower with VFD. (2.2KW)
Supply, Installation, Testing and Commissioning of 160mm dia UPVC tube grey.
Supply, Installation, Testing and Commissioning of 160mm dia UPVC tube grey Bends.
Supply, Installation, Testing and Commissioning of 160mm dia UPVC transparent tube.
Supply, Installation, Testing and Commissioning of 160mm dia UPVC Tube transparent Bends.
Supplying, installation, testing & commissioning of Carrier 160 mm with 2 programmable RFID tag for easy return of empty carrier.(Inload size: 330x115)
Supplying, installation, testing & commissioning of Carrier 160 mm with 2 programmable RFID tag for easy return of empty carrier. (Inload size: 400x115)
Misc. Installation accessories sourced from India including Pipe Clamps, Srew Bolts, Cable Clips, Hose Clamps & Baskets, Cushions and Racks for Stations etc etc
CURTAIN TRACK SYSTEM
Providing and installation of Cubical tracks system made of Powder coated Aluminium alloy, mounted on the ceiling using Suspension hangers and bushes, powder coated wall bracket and Track Joiners wherever required.This system shall be complete with stain free polyster fabric, Water repellent Curtains having 18" Net on top. The curtain shall be approx 7X4 feet, with two curtains stiched together wherever required. Curtains shall also be provided with smooth movement, non sticking runners, with Stainless steel hooks, for easy movement. The system shall have curtain removal points and end cap, wherever required.
Supplying & installation of 1 Pc of I.V. Hanger with 5 hooks, made from mirror finish stainless steel, 304 grade with adjustable height, provided with 4/6 feet aluminium alloy track powder coated with endcap of tracks, 1 pc of trolley for smooth IV Hanger movement on track, 2 pcs of suspension hanger powder coated, top & bottom bush, powder coated, for easy fitting and better aesthetics.
HVAC WORK
AHRI CERTIFIED CENTRIFUGAL WATER COOLED CHILLING MACHINE
Supply, installation, testing and commissioning of Water Cooled Centrifugal Chilling M/C of 600 TR actual capacity at below mentioned operating conditions with ozone friendly, CFC-HCFC free (R-134 A) refrigerant, open / semihermatic / hermatically sealed Centrifugal compressor, direct / gear driven by suitable KW Sq. Cage induction motor complete with variable speed drive, water-cooled shell & tube condenser, insulated shell and tube flooded chiller, flow switches at condenser & chiller outlet, refrigerant piping, Refrigerant and Oil (First Charge), flexible pipe connector at condenser & chiller inlet / outlet, integral lubrication system, Microprocessor based control panel, factory supplied chiller mounted / floor standing Variable Speed Drive(VSD) with Active harmonic filter (Harmonics limit within 5%) & accessories etc. all mounted on M.S. frame. Suitable capacity squirrel cage induction motor with class 'B' insulation suitable for operation on 400+/-10% volts, 50Hz, A.C. supply. The Unit shall be mounted IP 54 rated VFD Starter of suitable capacity. The chilling m/c as described above shall be in line with specifications & shall have interface card compatible with BMS system.
Twin rotor based semi-hermetic type single/ multiple horizontal compressor complete with automatic capacity control from 100%-20%, safety switches, forced feed lubrication system etc., as per specifications. 1 no. - matching shell & tube flooded/falling film type even water pass chiller for Centrifugal type units of MS shell and copper tubes and pressure drop not exceeding 10.0 meters as per CPWD Specifications. Evaporator and condenser shall be manufactured, tested and stamped with ASME(U) pressure vessel code.
All Chiller shall be tested at 4 points at 100%, 75%, 50% and 25% at AHRI conditions at manufacturer test bed before dispatch.
Water flow switches at outlet of condenser & chiller, water drain, air purge valves, thermometers and pressure gauges wherever required.
Initial/first charge of refrigerant gas & compressor oil shall be factory charged. Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications, liquid level control etc.
Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti-vibration pads/springs. RCC / cement concrete foundation for the chilling unit.
CONDENSOR SIDE
CDW IN - 32.22º C.
CDW OUT - 37.77º C.
FLOW - 6820 LPM
Fouling Factor (MKS) - 0.0002
Pressure Drop Max - 8.5 Meter
CHILLER SIDE
CHW IN - 12.20º C.
CHW OUT - 6.67º C.
FLOW - 5450 LPM
Fouling Factor (MKS) - 0.0001
Pressure Drop Max - 7.5 Meter
IKW / TR (Maximum) - 0.68
ARI Certified Centrifugal Water Cooled Chilling Machine With Variable Speed Drive & Microprocessor Based Control Panel Of Capacity 600 TR (3W + 1S) The price quoted for supply, installation, testing & commissioning of Centrifugal Chilling Unit shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees.
CHILLER PLANT OPTIMISER
Supply, installation, testing and commissioning of 64 bit, UL Listed BACnet (BTL certified) Supervisory Controller for management level interface in MS Mild Steel Enclosure powder coated grey colour for SUPERVISORY CONTROLLER, IO CARDS (with accessories like Transformer, MCB, internal wiring and Relays with bases) (A) The Network supervisory Controller shall have imbedded graphic capability for generating web based user graphics and support Multi user with simultaneous minimum 4 user login facility (B) Unlimited user without additional license (C) Shall be browsed by Microsoft Internet Explorer and Netscape Navigator (D) BTL certified (E) Web engine should be 64 bit configuration (F) Should have inbuilt IO points (G) Functionally able to act as a DDC controller also apart from Supervisory controller function (H) Web engine should support ASHRAE standard BACnet MS/TP protocol, Proprietary Protocol shall not be accepted (I) Web engine should support integration of third party protocol ( eg Modbus-RTU) seamlessly without adding additional hardware (J) Web engine should support DHCP function for IP addressing. (K) All Peripheral Systems required to complete the work of CPO.
All equipment in the Centralized Chilled Water Plant Shall be Controlled through Chiller Plant Optimiser.
All field devices and sensors required for the operation of CPO shall be paid separately under BMS BOQ
All Cables used for the CPO shall be screened LSZH type. The cables, conduits, cable tray & glands will be paid separately as per actual measurements in Electrical BOQ.
PRIMARY CHILLED WATER PUMPS
Supply, installation, testing and commissioning of End Suction chilled water centrifugal pump sets with bronze impeller for chilled water recirculation complete with TEFC Sq. Cage induction motor with class "F" insulation, base plate, coupling guard, vibration isolators, SS Shaft, factory fitted mechanical seal, flexible pipe connector at inlet and outlet etc. conforming to technical specification & as per following parameters. The chilled water pumps shall also include the cost of thermal insulation. (4W+1S)
Capacity of Each Pump (LPM) 5450
Pump Head (Mt) 20.00
Motor HP 40.0
Minimum Efficiency 70 %
Chilled Water Pump Sets (4W+1S) as mentioned above. The price quoted for supply, installation, testing & commissioning of imported Pumps shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees.
SECONDARY CHILLED WATER PUMPS
Supply, installation, testing and commissioning of End Suction chilled water centrifugal pump sets with bronze impeller for chilled water recirculation complete with TEFC Sq. Cage induction motor with class "F" insulation, base plate, coupling guard, vibration isolators, SS Shaft, factory fitted mechanical seal, flexible pipe connector at inlet and outlet etc. conforming to technical specification & as per following parameters. The chilled water pumps shall also include the cost of thermal insulation. Secondary chilled water pumps shall be suitable for operation on adjustable frequency drives & conforming to the specifications of variable speed pumping system.
Capacity of Each Pump (LPM) 5450
Pump Head (Mt) 35.00
Pump Motor HP 75
Minimum Efficiency 80 %
Working + Standby 4+2
Chilled Water Pump Sets (3W+2S) as mentioned above. The price quoted for supply, installation, testing & commissioning of imported Pumps shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees.
VARIABLE SPEED PUMPING SYSTEM
Supply, installation, testing and commissioning of Variable Speed Pumping system consisting of four numbers 80 HP adjustable frequency drive (AFD) suitably interfaced with other system components, hand / auto macro designed for pumping application, 01 no. dedicated microprocessor based pump logic controller, parallel pumping software duly downloaded, 02 No. Differential Pressure Sensor / Transmitters, interfacing amongst all components and compatibility of I/O signals etc. complete with other accessories as required.
The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees. (For Chilled Water Secondary Pump & Condenser Water pump)
AIR SEPARATOR
Supply Installation Testing and Commissioning of In-line Air Separator removing of free air, bubbles and microbubbles within chilled water system. The acceptable design shall incorporate a separating element to force inline water into tranquillity zones for air removal. A nozzle shall force de-aerated water into the main flow to divert contaminated water through the separating element.Floating debries and scum shall be removed via a high level drain valve.A high capacity, conical brass automatic air vent shall be installed on the top of the vessel for air discharge. It shall be able to remove at least 15% of 70 µm microbubbles per cycle. The Microbubble Air separator shall be sized appropriate to the maximum operating pressure and flow velocity of the system. Inlet and outlet of the unit (Dia-500mm). Manufactured and designed in accordance with European Pressure Equipment Directive PED 97/23/EC. Material shall be EN/ISO: S235JR+N, shall be via horizontally-opposed, coaxial flanged connections in accordance with EN 1092-1 PN 10 Suitable for glycol solution upto 50%, Temperature range -10 °C to 120 °C Line Size:300 mm diameter. Air Separator shall have third party certificate (TUV / lloyds registered). Line Size:400 mm diameter. Line Size:500 mm diameter Approved Makes : Flamco/IMI/Spirotech/Caleffi
The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees.
Supply Installation Testing and Commissioning of In-line Air & Dirt Separator. removing of free air, bubbles and microbubbles in combination with separation and removal of dirt particles within chilled water system. The acceptable design shall incorporate a separating element to force water into tranquillity zones for air and dirt removal. A nozzle shall force de-aerated water into the main flow to divert contaminated water through the separating element.The use of tube mesh and wire mesh made of copper or any metal is not permitted for separation purpose, wire mesh/tube increases the pressure drop and maintenance requirement. A high capacity, conical brass automatic air vent shall be installed on the top of the vessel for air discharge. Drain valve for removal of floating debris and dirt. Heavier than water dirt particles shall be removed via a blow down valve on the base of the vessel whilst ferrous particles down to 4 µm shall be captured by a magnetic device(25 Neodymium Supermagnets) in the lower part of the vessel. It shall be able to remove at least 15% of 70 µm microbubbles per cycle and at least 35% of 150 µm dirt particles per cycle. Manufactured and designed in accordance with European Pressure Equipment Directive PED 97/23/EC. Material shall be EN/ISO: S235JR+N. The Microbubble Air and Dirt Separator shall be sized appropriate to the maximum operating pressure of the system. Inlet and outlet of the unit (Dia-250 mm.) shall be via horizontally-opposed, coaxial flanged connections in accordance with EN 1092-1 PN 16. Suitable for glycol solution upto 50%, Temperature range -10 C to 120 C. Line Size:450 mm diameter
The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees.
FRP INDUCED DRAFT COOLING TOWER (700 TR)
Supply, installation, testing and commissioning of FRP Induced draft, cross/counter flow, twin/four cell, direct/ gear driven, site erected cooling tower of capacity 700 TR (26,47,400 Kcal/Hr.) based on the parameters given below and complete with PVC Fill, Louvers, Drift Eliminator, TEFC Motor, Propeller Fan, PVC Sump & Steel Ladder etc. The cooling tower shall conform to technical specifications given in the tender. The maximum allowable sound power at a distance of 1 M from the cooling Tower shall be less than 75 dB. The cooling Tower Model shall be to suit site condition.
Duty Parameters
Capacity -700 TR (26,47,400 Kcal/Hr)
Designed Wet Bulb Temperature - 28.3 °C
Water Inlet Temperature - 37.77 °C
Water Outlet Temperature - 32.22 °C
The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, etc. as required in Indian Rupees.
CONDENSER WATER PUMPS
Supply, installation, testing and commissioning of Horizontal Split Casing condenser water centrifugal pump sets with bronze impeller for condenser water recirculation complete with TEFC Sq. Cage induction motor with class "F" insulation, base plate, coupling guard, vibration isolators, SS Shaft, factory fitted mechanical seal, flexible pipe connector at inlet and outlet etc. conforming to technical specification & as per following parameters: (4W+1S)
Capacity of Each Pump LPM 6820
Pump Head (Mt) 35.00
Motor HP 100.0
Minimum Efficiency 80 %
The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, etc. as required in Indian Rupees.
SIDE STREAM FILTRATION SYSTEM
Supply, Installation, testing and commissioning of SIDE STREAM FILTRATION SYSTEM to remove unwanted solids from Condenser loop using Lakos centrifugal-action Lakos vortex separator. Control of solids in the recirculated cooling water system shall be accomplished via a side-stream flow of 10-25% of the full-stream system flow through a completely assembled separation / filtration package. The package's pump shall provide sufficient pressure for the re-introduction of side-stream fluid back into system flow.The side stream filteration unit shall be of suitable for 840 USGPM flow rate and pressure drop of 0.2 - 0.8 Bar, Maximum working pressure of 10.3 Bar and Maximum operating temperature of 60 deg.C. The complete packaged unit shall consist of the following
End-suction, single stage; TEFC motor; iron / Bronze impeller; flooded suction required.
Seperator
Centrifugal-action accessible design, incorporating a true tangential inlet and mutually tangential Swirlex internal accelerating slots, employed to promote the proper velocity necessary for the removal of the separable solids. The internal accelerating slots shall be spiral-cut for optimum flow transfer, laminar action and particle influence into the separation barrel. Avoid Dome type or Dumbbell type of Separator construction to prevent the lack of internal method of acceleration & efficiency. The separator's internal vortex shall allow this process to occur without wear to the accelerating slots. Separated particle matter shall spiral downward along the perimeter of the inner separation barrel, in a manner which does not promote wear of the separation barrel, and into the solids collection chamber, located below the vortex deflector plate. The separator shall be of unishell construction with SA-36, SA-53B or equivalent quality carbon steel, minimum thickness of .25 inches (6.35 mm). Level of filtration & effectiveness must be as per given specification, Performance Testing must be done by an independent and identified testing laboratory for any of the separator.
Automatic Purge Valve
An electrically-actuated valve programmed at appropriate intervals and duration in order to efficiently and regularly purge solids from the separator's collection chamber.
Electrical control
Skid Plate
Steel, 3/16-inch (5 mm) minimum thickness or Steel Structural base Approved Make : Lakos/Towerflo/Towerscour
HOT WATER GENERATOR
Supply, installation, testing and commissioning of Hot Water Generator With VFD for Monsoon Reheat of capacity 250 KW in three banks complete with controls, electrical panels etc. confirming to technical specifications Section.
Inlet Water Temperature 44.44 °C (112°F)
Outlet Water Temperature 54.44 °C (130°F)
The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees. (2W+1S)
HOT WATER PUMPS
Supply, installation, testing and commissioning of Monoblock hot water centrifugal pump sets with VFD.Pump Sets having bronze impeller for hot water recirculation complete with TEFC Sq. Cage induction motor with class "B" insulation, base plate, vibration isolators etc. conforming to techinical specification and as per following parameters. The hot water pumps shall include thermal insulation & cladding.
Capacity of Each Pump LPM -360
Pump Head (Mt) -35.0
Motor HP -15 HP
The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, etc. as required in Indian Rupees. (2W+1S)
VARIABLE SPEED HYDROPNEUMATIC SYSTEM
Supply, installation, testing and commissioning of variable speed (VSPS) hydropneumatics system mounted on a common base plate comprising of vertical centrifugal pumping set with S.S body, stainless steel impeller and mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, one No. microprocessor based controller, dedicated variable frequency drive for each pump, one No.remote sensors, pressure transducers, sequence running controller, dry running Protection, motor control center, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 90 liter capacity M.S diaphragm tank with interchangeable butyl rubber membrane, complete in all respects including stainless steel grade 316 pipe suction and delivery headers and isolation/ control valves( ball valves/butterfly valves/ Nan return valves/ vibration eliminators etc. as required) , power box, equipped with fuses/ isolators/circuit breakers as required.
Hyd. System for Soft Water Supply Pump (SS BLOCK)
Flow rate : 310.0 LPM each (4hr Working)
Pumping Head - 60/65 m
Approx. H.P. - 15 HP or as per manufacturer recommendation.
1 Set = 3 Nos. pump (2 working+1 standby)
AIR COOLDED VARIABLE REFRIGERANT VOLUME/FLOW AIR CONDITIONING SYSTEM
Supply, Installation, testing and commissioning of air cooled Variable Refrigerant Volume/Flow modular type air-conditioning system Invertor Controlled with step less modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications and having following items: Refrigerant to be used shall be - R - 410 A.
OUTDOOR UNIT
Supply, Installation, testing and commissioning of Both Cooling & Heating Modular type outdoor units suitable to operate at 415 ± 10 % volt, 50 Hz, 3 phase AC supply and suitable for cooling & Heating application by using 100 % inverter driven capacity control compressors (Hermetically sealed scroll type) with stepless modulation complete with special acryl precoated heat exchanger, minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), low noise condenser fan , auto check function for connection error in display panel, auto address setting as per specifications. The COP at AHRI conditions shall not be less than 3.8 . Complete Set (Indoor and Outdoor) of equipment testing shall be done in the presence of client representative at AHRI Conditions without any extra cost. The units shall be complete with necessary mounting frames and capacity as mentioned below and as per specification.
The cost should include the following :
Nitrogen pressure testing for refrigerant pipe leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts. Refrigerant gas & oil charging as per OEM standard.
Necessary corrosive treatment of copper coil of the ODU with Aluminium hydroxide, 25 microns thickness or equivalent coating as per manufacturer standard to protect from corrosion, sulphur and other chemical contaminants present in the air. The coating should be done in the presence of OEM representative. The coating shall be carried-out by the authorized applicator of coating manufacturer.
Note : The ODU provided with cowl duct for exhaust air should have minimum 5 mm ESP. GI wire mesh (minimum 16 SWG thickness) type bird screen with framing at the Mouth of exhaust air Cowl duct of Outdoor Units, where ever required.
ODU Units Mounted on MS Frame/Masonry Pedestal with required anti-vibration mounting.
Note For Computer Lab-AC Machine will Be Cooling Only
12 HP (1x12 HP)
14 HP (1x14 HP)
16 HP (1x16 HP)
18 HP (1x18 HP)
20 HP (1x20 HP)
Indoor VRV/VRF Units
Supply, Installation, testing & commissioning of metallic body indoor (Hi-Wall, Cassette & Ducted) Units of following minimum capacity suitable to operate at 230+/-10% volt, 50 HZ, 1 phase power supply and having multispeed motor, blower, coil section with DX coil, outer cabinet, drain pan, drain pump, drain water lift-up mechanism, insulation, pipe connections, fittings & required cable to connect indoor unit to MCB etc. complete in all respect and as per specification.
Indoor Units powder coated MS Hanging arrangement/wall Brackets with required anti-vibration mounting.
CEILING MOUNTED 4-WAY/1-WAY CASSETTE UNITS
Supply, installation, testing and commissioning of following minimum capacity 1-Way/4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
Indoor Units powder coated MS Hanging arrangement/wall Brackets/Spring Isolators with required anti-vibration mounting.
4-Way Cassette Unit
0.8 TR (275 CFM)
1.2 TR (400 CFM)
1.5 TR (550 CFM)
2.0 TR (700 CFM)
2.5 TR (800 CFM)
3.0 TR (1050 CFM)
4.0 TR (1250 CFM)
WALL MOUNTED HIGH WALL TYPE
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
Indoor Units powder coated MS Hanging arrangement/wall Brackets/Spring Isolators with required anti-vibration mounting.
1.1TR (350 CFM)
1.6 TR (525 CFM)
2.1 TR (625 CFM)
CEILING SUSPENDED DUCTED TYPE UNITS
Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pump, drain pan, fire retardant non-porous double layer flexible connection, other necessary supports etc., suitable for operation on single phase AC supply 230 V± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
Indoor Units powder coated MS Hanging arrangement/wall Brackets/Spring Isolators with required anti-vibration mounting and Fire Rated Flexible Connection.
Mid Static Ductable units (minimum 50 pascal external static pressure)
1.0 TR (375 CFM)
1.3 TR (450 CFM)
1.5 TR (525 CFM)
Mid Static Ductable units (minimum 100 pascal external static pressure)
2.0 TR (700 CFM)
2.5 TR (900 CFM)
3.0 TR (1200 CFM)
High Static Ductable units (minimum 150 pascal external static pressure)
4.0 TR (1400 CFM)
4.5 TR (1800 CFM)
5.5 TR (2100 CFM)
6.5 TR (2600 CFM)
8.0 TR (3000 CFM)
CEILING SUSPENDED TREATED FRESH AIR UNITS
Supplying, installing, testing and commissioning of Ceiling Suspended Treated Fresh air Units each complete with coil, filter, etc. Air conditioners with evaporating unit comprising of cooling coil, blower with motor and 220 volt, 1 phase, 50 Hz, AC supply all as per specifications. The rate will also include entire drain pipes and nothing extra shall be payable.
5.5 TR (800CFM)
6.5 TR (950CFM)
Refrigerant Joints and Headers
Supply, Installation, Testing and Commissioning of copper Y-Joints sets, distributer and headers, suitable for various sizes of gas and liquid line of VRF System complete as required for the above system.
Corded/Cordless Remote Controller
Supply, Installation, testing and commissioning of self diagnostic type Corded/Cordless remote controllers for operation of indoor units.
Central Remote Controller
Supply, Installation, testing & commissioning of Main intelligent central controller with Scheduled Timer system Touch screen/Gate Way Type suitable for groups of indoor units to operate, monitor, on/off, cyclic operation setting, temperature setting etc. The controller shall be able to control up to minimum nos. of indoor units with zoning option as mentioned below. The controller shall have wide screen user friendly colour LCD Touch screen display and can be wired by a non-polar transmission cable The CRC shall be provided with suitable size metallic box with lock arrangement. The controller shall be integrated to BMS system thru software for monitoring & controlling of all above parameters including start/ stop of each indoor / outdoor unit. All necessary interface cards / units should be supplied as a part of the system to integrate to the BMS Software.
Maximum 64 Nos of Indoor Units
Air Cooled Ductable Unit
Supplying, installing, testing and commissioning of Air Cooled Ducted Air conditioners suitable for R410A or eco-friendly refrigerant with evaporating unit comprising of cooling coil, blower with motor in Metallic (Steel) casing and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, Expansion kit to connect with DX AHU, and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting.
Providing, fixing and testing of copper refrigerant piping of appropriate sizes duly insulated with nitrile rubber insulation of 19 mm thickness. The pipes plus nitrile rubber insulation and cable are to be covered with PVC flexible conduits for protection.
Note: Providing and fixing of Powder coated M.S. angle iron frame work/Masonry Pedestal with required anti-vibration mounting for outdoor unit is also included in the above scope. Contractor to submit design/Scheme for Iron frame and obtain approval of engineer/employer before proceeding purchase & installation.
Nitrogen pressure testing for refrigerant pipe leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts. Refrigerant gas & oil charging as per OEM standard.
Necessary corrosive treatment of copper coil of the ODU with Aluminium hydroxide, 25 microns thickness or equivalent coating as per manufacturer standard to protect from corrosion, sulphur and other chemical contaminants present in the air. The coating should be done in the presence of OEM representative. The coating shall be carried-out by the authorized applicator of coating manufacturer.
4.0 TR (1600 CFM) Ductable Split Unit
5.5 TR (2200 CFM) Ductable Split Unit
8.5 TR (3400 CFM) Ductable Split Unit
11.0 TR (4400 CFM) Ductable Split Unit
REFRIGERANT PIPING
Supply, fixing, testing and commissioning of interconnecting soft/hard drawn copper refrigerant pipe work of following outer diameter duly insulated with fire rated class'O' closed cell elastomeric nitrile rubber insulation (19mm/13mm thick) between indoor & outdoor units & protected with 26 G aluminium sheet cladding as per specifications. All piping should be laid on Galvanized/Powder Coated tray supported by Galvanized M S Hangers & Clamps and all external piping shall run in covered cable trays. The rate includes all the items required to complete the piping work and nothing extra should be payable except the cable tray.
Vaccumiazation & Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU.
Civil Work such as wall hole making , wall chiselling ,refilling of chiselling part with mortar etc. as per site condition.
Covering of External refrigerant piping insulation shall be done with 26 G aluminium sheet cladding as per specifications.
Internal Refrigerant piping insulation shall be covered with Aluminium Foil as per specifications.
6.4 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
9.5 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
12.7 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
15.9 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
19.1 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
22.2 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
25.4 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
28.6 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )
31.8 mm outer dia Hard Drawn with Tube Thickness-1.62mm ( Insulation-19 mm )
34.9 mm outer dia Hard Drawn with Tube Thickness-1.62mm ( Insulation-19 mm )
38.1 mm outer dia Hard Drawn with Tube Thickness-1.62mm( Insulation-19 mm )
41.3 mm outer dia Hard Drawn with Tube Thickness-1.62mm( Insulation-19 mm )
AIR CONDITIONING EQUIPMENTS LOW SIDE
DOUBLE SKIN FLOOR MOUNTED AIR HANDLING UNIT WITH PRE-FILTER
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/ PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 4/6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for variable frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities
The cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90%, complete with motor, belt drive etc. without face and bypass dampers. The AHU panels shall be insulated with 25mm thick & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminium extruded section with starter panel. The complete AHU shall conform to standard specification. The face velocity across cooling coil shall be limited to 152 MPM maxm. The capacity of Air-handlers shall be as follows:
Chemical, Biological and Radiological (CBR) filtration with dia-electric media with efficency not less than <90 % of PM .1 micron alongwith <95 % of gases contamination removal with 350 mm depth (CBR- Certification IACS for filteration efficiency, Green Pro, ISO, FDA & RoHS - refer details specifcation for CBR Filter for compliance) in the AHU along with necessary frames, Air Decontamination Chamber in the supply air/ plenum comprising of nanoX coating plasmOX having EPA approved metallic compound of five metals targeted on Alumninum matrix cell duly enclosed by a poly quartz casing tube with the capability to produce ionized Hydroxyl oxidizers having required wattage for different CFM's. The Equipment shall a microbiological testing report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along with a Virology report from ICMR approved lab with an minimum efficiency of 99 percent against SARS COV2 within 45 minutes
5,000 CFM (8500 CMH), 50 mm St. Pr., 6 Row CC
6,000 CFM (10200 CMH), 50 mm St. Pr., 4 Row CC
6,000 CFM (10200 CMH), 50 mm St. Pr., 6 Row CC
7,000 CFM (11900 CMH), 50 mm St. Pr., 4 Row CC
7,000 CFM (11900 CMH), 50 mm St. Pr., 6 Row CC
8,000 CFM (13600 CMH), 50 mm St. Pr., 4 Row CC
8,000 CFM (13600 CMH), 50 mm St. Pr., 6 Row CC
9,000 CFM (15300 CMH), 50 mm St. Pr., 4 Row CC
9,000 CFM (15300 CMH), 50 mm St. Pr., 6 Row CC
10,000 CFM (17000 CMH), 50 mm St. Pr., 4 Row CC
10,000 CFM (17000 CMH), 50 mm St. Pr., 6 Row CC
11,000 CFM (18700 CMH), 50 mm St. Pr., 4 Row CC
12,000 CFM (20400 CMH), 50 mm St. Pr., 4 Row CC
DOUBLE SKIN FLOOR MOUNTED AIR HANDLING UNIT WITH FINE FILTER
Supply, installation, testing and commissioning of factory fabricated Double Skinned Chilled Water Air- handling unit floor mounted fabricated out of extruded aluminium section with 0.8mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.8 mm Galvanised steel sheet inside with fan & fan section, fan motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 4/6 row cooling & 2 row heating coil made of Aluminium finned Copper tube, Copper header with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90%, fine filter section with filters of non woven synthetic media of 5 micron particle size, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with motor, belt drive package, guard etc. without face and bypass dampers. The AHU panels shall be insulated with 23mm thick & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminium extruded section only with starter panel. The complete AHU shall conform to standard specification. The face velocity across cooling / heating coil shall be limited to 152 MPM maxm. The capacity of Air-handlers shall be as follows:
Chemical, Biological and Radiological (CBR) filtration with dia-electric media with efficency not less than <90 % of PM .1 micron alongwith <95 % of gases contamination removal with 350 mm depth (CBR- Certification IACS for filteration efficiency, Green Pro, ISO, FDA & RoHS - refer details specifcation for CBR Filter for compliance) in the AHU along with necessary frames, Air Decontamination Chamber in the supply air/ plenum comprising of nanoX coating plasmOX having EPA approved metallic compound of five metals targeted on Alumninum matrix cell duly enclosed by a poly quartz casing tube with the capability to produce ionized Hydroxyl oxidizers having required wattage for different CFM's. The Equipment shall a microbiological testing report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along with a Virology report from ICMR approved lab with an minimum efficiency of 99 percent against SARS COV2 within 45 minutes
3,000 CFM, 50 mm St. Pr., 6 Row CC, 2 Row HC
4,000 CFM, 50 mm St. Pr., 6 Row CC, 2 Row HC
5,000 CFM, 55 mm St. Pr., 6 Row CC, 2 Row HC
6,000 CFM, 55 mm St. Pr., 6 Row CC, 2 Row HC
7,000 CFM, 55 mm St. Pr., 6 Row CC, 2 Row HC
8,000 CFM, 65 mm St. Pr., 6 Row CC, 2 Row HC
9,000 CFM, 65 mm St. Pr., 6 Row CC, 2Row HC
10,000 CFM, 65 mm St. Pr., 6 Row CC, 2Row HC
DOUBLE SKIN FLOOR MOUNTED AIR HANDLING UNIT WITH HEPA FILTER
(For OT With 10 ACPH/Hr)
Supply, installation, testing and commissioning of factory fabricated Double Skinned Chilled Water Air- handling unit floor mounted fabricated out of extruded aluminium section with 0.8mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.8 mm polished SS sheet inside with backward curved fan in supply and forward curved in exhaust with fan section and fan motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 8 row cooling & 2 row heating coil made of Aluminium finned Copper tube, Copper header with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% in both the supply & exhaust side of AHU, fine filter section with filters of non woven synthetic media of 5 micron particle size in supply after fan, (Hepa filters shall be at terminals along with laminar flow plenum & not to be included in the cost), mixing chamber, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with motor, belt drive package, guard etc. without face and bypass dampers. The AHU panels shall be insulated with 48mm thick & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminium extruded section only with starter panel. These AHUs shall have air inlet / outlet connection made of aluminium 20 G & all fixing arrangement / blank off shall be of SS The complete AHU shall conform to standard specification. The face velocity across cooling / heating coil shall be limited to 152 MPM maxm. The capacity of Air-handlers shall be as follows:
3000 CFM Supply Air, 8 Row CC, 2 Row HC, 125 mm St. Pr., For Supply Fan, Supply Fan, 1000 CFM Ex. Air Blower, 40 mm St. Pr. for Exhaust fan with other accessories as specified)
DOUBLE SKIN FLOOR MOUNTED AIR HANDLING UNIT WITH HEPA FILTER
(For OT With 100% FRESH AIR)
Supply, installation, testing and commissioning of factory fabricated Double Skinned Chilled Water Air- handling unit fabricated out of extruded aluminium section with 0.8mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.8 mm polished SS sheet inside with backward curved fan in supply and forward curved in exhaust with fan section and fan motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 8 row cooling & 2 row heating coil made of Aluminium finned Copper tube, Copper header with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% in both the supply & exhaust side of AHU, fine filter section with filters of non woven synthetic media of 5 micron particle size in supply & exhaust after fan, (Hepa filters shall be at terminals along with laminar flow plenum & not to be included in the cost), Heat Recovery Wheel with HRW Section, mixing chamber, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with motor, belt drive package, guard etc. without face and bypass dampers. The AHU panels shall be insulated with 48mm thick & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminium extruded section only with starter panel. These AHUs shall have air inlet / outlet connection made of aluminium 20 G & all fixing arrangement / blank off shall be of SS The complete AHU shall conform to standard specification. The face velocity across cooling / heating coil shall be limited to 152 MPM maxm. The capacity of Air-handlers shall be as follows:
NOTE: The supply & exhaust part of this AHU shall have items / sections as mentioned above in the the following order.
Supply Part : Fresh air intake, pre filter section, HRW, cooling & heating coil, supply fan, Fine Filters, Outlet.
Exhaust Part : Return air intake, pre filters, HRW, exhaust air fan, Fine Filters & exhaust.
3500 CFM Supply Air, 8 Row CC, 2 Row HC, 140 mm St. Pr., For Supply Fan, Supply Fan, 3000 CFM Ex. Air Blower, 60 mm St. Pr. for Exhaust fan with other accessories as specified)
DOUBLE SKIN CEILING SUSPENDED AHU
Supply, installation, testing and commissioning of factory fabricated Double Skinned Chilled Water Air- handling unit ceiling suspended type fabricated out of extruded aluminium section with 0.8mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.8 mm plain Galvanised steel sheet inside with blower, blower section and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 4 Row cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90%, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with motor, direct / belt drive as mentioned below etc. without face and bypass dampers. All direct driven fan motor shall be sourced from fan manufacturer & factory fitted only. The AHU panels shall be insulated with 23mm thick & 36 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only with starter panel. The complete AHU shall conform to standard specification. The face velocity across cooling coil shall be limited to 152 MPM maxm. The capacity of Air-handlers shall be as follows:
Chemical, Biological and Radiological (CBR) filtration with dia-electric media with efficency not less than <90 % of PM .1 micron alongwith <95 % of gases contamination removal with 350 mm depth (CBR- Certification IACS for filteration efficiency, Green Pro, ISO, FDA & RoHS - refer details specifcation for CBR Filter for compliance) in the AHU along with necessary frames, Air Decontamination Chamber in the supply air/ plenum comprising of nanoX coating plasmOX having EPA approved metallic compound of five metals targeted on Alumninum matrix cell duly enclosed by a poly quartz casing tube with the capability to produce ionized Hydroxyl oxidizers having required wattage for different CFM's. The Equipment shall a microbiological testing report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along with a Virology report from ICMR approved lab with an minimum efficiency of 99 percent against SARS COV2 within 45 minutes
2,000 CFM, 32 mm St. Pr., 4 Row CC
2,000 CFM, 35 mm St. Pr., 6 Row CC
2,500 CFM, 32 mm St. Pr., 4 Row CC
2,500 CFM, 32 mm St. Pr., 6 Row CC
3,000 CFM, 35 mm St. Pr., 4 Row CC
3,500 CFM, 35 mm St. Pr., 4 Row CC
4,000 CFM, 35 mm St. Pr., 4 Row CC
4,500 CFM, 35 mm St. Pr., 4 Row CC
5,000 CFM, 35 mm St. Pr., 6 Row CC
6,000 CFM, 35 mm St. Pr., 6 Row CC
FAN COIL UNIT (FCU)
1.0 TR (400 CFM)
1.5 TR (600 CFM)
2.0 TR (800 CFM)
2.5 TR (1000 CFM)
3.0 TR (1200 CFM)
4.0 TR (1600 CFM)
THERMOSTAT FOR AHU & FCU
Supply, installation, testing and commissioning of digital display type thermostat for air handling unit for cool / heat application suitable for four pipe system & humidistat suitable for working with humidifier and hot water coil control valves for various air handling Units.Controller have provision to display differential pressure accress OT if required. The thermostat shall have provision of setting of space temperature and display of the same.
The humidistat shall have provision of setting space RH and display of the same. The quoted price of thermostat / humidistat shall include the cost of 20mm MS conduits, control cabling, MS Box etc as required. The cost quoted shall be excluding the control valves and humidifier
Cooling / heating Digital display type common thermostat & humidistat to be installed in OT & shall have temperature & RH setting control from OT as & when required.
Cooling / heating thermostat for balance AHU
Snap Acting Humidistat at air-handler.
THERMOSTAT FOR FCU
Supply, installation, testing and commissioning of automatic control for Fan Coil Units consisting of pressure independent balancing cum two way control valve (already quantified above) & digital thermostat, which will have provision of setting of room temperature, setting of fan speed (High, Medium, Low) and shall display the inside RH.
HUMIDIFICATION PACKAGE
Supply, installation, testing and commissioning of Humidification package with all necessary controls as required as per standard specification & of following capacities:
LAMINAR AIR FLOW
Supply, installation & testing of factory fabricated Laminar air flow pattern perforated plenum made of 16 G aluminium sheet with hepa filters & suitable for operation theatre with all accessories as required to suit, site condition as per specifications.
SIZE-2.4mx2.7m
SIZE-2.4mx2.4m
AIR OZONE SYSTEMS
Supply, installation, testing, commissioning and handing over the air ozone systems for maintaining indoor air quality. The components of the system must be in strict conformity with the technical specifications. The price to include all connected wiring between the duct mounted ozone generator, VOC sensor / controller. The single phase power supply to the ozone generator / monitor shall be provided near the controllers. Common area ceiling hung AHU shall not have this facility.
The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees.
Ozone Generator With Sensor & VOC Controller (at Each Floor)
ULTRA VOILET GERMICIDAL IRRADIATION SYSTEM (UVGI )
DBD Bi Polar Ionization
Supply, installation, testing & commissioning of Dielectric Barrier Discharge (DBD) Bi-Polar Ionization System to remove the odour, VOCs, Molds, Viruses, Bacteria's, Pathogens, PMs . Bipolar ionization system must have compliances to below reference codes and standards : 1.UL 2998 Ozone Free Compliance 2. UL 867-2013 Ozone Standard for Electrostatic Air Cleaners including ozone chamber test 3. IP66 Enclosures 4. UL 1995 Heating and Cooling Equipment. 5. UL 2043 Standard for Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces. 6. OPA 2807-10, OPA 2808-10 7. ASHRAE 62.1
The bipolar ionization air purifiers shall have been independently tested by a third-party to ANSI/AHAM AC-1-2002 and provide a minimum Clean Air Delivery Rate (CADR) performance of 125 Dust CADR and 190 Mold CADR. Any bipolar ionization system not tested or rated above a 100 CADR is not allowed. Bipolar ionization manufacturer must have third party laboratory testing results proving contaminant and pathogens reductions against COVID thru ASTM Test Method(> 99.9% efficiency), VOCs and TVOC (90% efficiency), MS2 (>95% efficiency), Staph (>95% efficiency), E. Coli (>95% efficiency), Dust-Particulate Matter 0.3 (>86% efficiency), Mold (>90% efficiency), and C. Dificile (>95% efficiency). Manufacturer shall furnish these reports on request. Ionization tubes must be constructed from durable, shatterproof composite material, not glass. Composite tubes must be able to last for 17,600 hours or more. Glass tubes are not be permitted due to potential of shatter caused by vibration. Tube must retain 90% of ion output efficiency at 17,600 hour mark. The units to be as per as per Specification for all re-circulating systems of following capacity of units as mentioned below. (Ground To Ninth Floor)
VARIABLE AIR VOLUME (VAV) BOX
Supply, installation, testing, and commissioning of pressure independent VAV boxes for cooling / heating application including 220 / 24 V transformers, wiring between transformers, temperature sensors for VAV box suitable for following air Quantity (CFM)
1000 to 1200 CFM
1201 to 1500 CFM
1501 to 1800 CFM
1801 to 2200 CFM
2201 to 2700 CFM
2701 to 3200 CFM
3201 to 3600 CFM
3601 to 4000 CFM
VARIABLE AIR VOLUME (VAV) Diffusers
Supply, Installation, Testing & Commission of 4-way Analog Type variable geometry VAV Diffuser (electronically Controlled) complete with Vary-Drive actuator, housing & appearance panel as per specifications.
Wall mounted Thermostat Unit
USB – Commissioning Module with cable
Power Module Unit
AIR COOLED SPLIT TYPE SPLIT UNITS AIR-CONDITIONER
Supplying, installing, testing and commissioning of Air Cooled Invertor Split type wall mounted /Ceiling suspended 5 Star Air conditioners suitable for R410A or eco-friendly refrigerant with evaporating unit comprising of cooling coil, blower with motor in Metallic (Steel) casing and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, drain pipes and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting. Nothing extra shall be paid on any account i.e. refrigerant pipes, drain pipes etc.
Providing, fixing and testing of copper refrigerant piping of appropriate sizes duly insulated with nitrile rubber insulation of 19 mm thickness and cabling for all types of split AC units. The pipes plus nitrile rubber insulation and cable are to be covered with PVC flexible conduits for protection.
Note: Providing and fixing of Powder coated M.S. angle iron frame work for outdoor unit is also included in the above scope. Contractor to submit design/Scheme for Iron frame and obtain approval of engineer/employer before proceeding purchase & installation.
Suitable Type Refrigerant & Drain Piping With Insulation, Control Cable, automatic voltage Stablizer and outdoor stand extra Cost shall be as per JSR-2022-E&M
Capacity : 1.5 TR 5 Star Split AC Inverter Type IS 1391 Part-II
Capacity : 2.0 TR 5 Star Split AC Inverter Type IS 1391 Part-II
Refrigerant Piping
Copper Tube of Size-6.4mm for Split Unit AC 1/1.5/2/3 TR Capacity
Copper Tube of Size-9.5mm for Split Unit AC 1/1.5/2/3 TR Capacity
Copper Tube of Size-12.7mm for Split Unit AC 1/1.5/2/3 TR Capacity
Copper Tube of Size-15.9mm for Split Unit AC 1/1.5/2/3 TR Capacity
Automatic Voltage Stablizer
4KVA Wall Mounted Automatic Voltage Stablizer from Range 140V to 280V
5KVA Wall Mounted Automatic Voltage Stablizer from Range 140V to 280V
Drain Pipe
Drain Pipe for AC
Outdoor Stand
Outdoor Stand for 1/1.5 TR Split Units
SCHEDULED TIMER FOR SPLIT AC
Supply, installation, testing and commissioning of Scheduled Timer for wall mounted split type Air conditioning units.
AXIAL FLOW FANS (SMOKE EXTRACTION/EXHAUST FAN)
Supply, installation testing & commissioning of Fire Rated direct driven Axial flow fan. Each fan shall be complete with casing made from mild steel duly enamel painted, adjustable pitch die cast aluminum impeller (HUB & BLADES), mounting clits, structural frame with blank-off sheet, anchor fastener with vibration isolation Springs, back draft damper(wherever required), bird screen at one sides (entry for supply air and exit for exhaust air) and rated Motor with class-H insulation. Motor shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply. with starter panel.
Fan and motor shall be fire rated to 250 Deg C for 2 hours or as indicated in the specifications
Back draft Damper : Where required for system design roof-mounted fan shall be equipped with a rattle-free back draft damper to prevent air from re entering the fan when fan is not in operation, thus sealing completely in closed position. Damper shall be chatter proof under all conditions.
Note:-These fans would be connected to the fire alarm system & BMS system of the building and would start automatically in case of Fire
1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second)
2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second)
3. Fan motor shall meet IE3 or above standard as per IS-12615
5. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm.
6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted.
Capacity 4000 CFM, SP 20 mm wg
Capacity 5000 CFM, SP 20 mm wg
Capacity 6000 CFM, SP 25 mm wg
Capacity 7000 CFM, SP 25 mm wg
Capacity 8000 CFM, SP 25 mm wg
Capacity 9000 CFM, SP 30 mm wg
Capacity 10,000 CFM, SP 30 mm wg
Capacity 11,000 CFM, SP 30 mm wg
Capacity 12,000 CFM, SP 30 mm wg
Capacity 14,000 CFM, SP 30 mm wg
Capacity 15,000 CFM, SP 30 mm wg
Capacity 16,000 CFM, SP 35 mm wg
Capacity 18,000 CFM, SP 35 mm wg
Capacity 20,000 CFM, SP 35 mm wg
Capacity 22,500 CFM, SP 35 mm wg
Capacity 25,000 CFM, SP 35 mm wg
AXIAL FLOW FANS (SUPPLY/PRESSURISATION FAN)
Supply, installation testing & commissioning of direct driven Axial flow fan. Each fan shall be complete with casing made from mild steel duly enamel painted, adjustable pitch die cast aluminum impeller (HUB & BLADES), mounting clits, structural frame with blank-off sheet, anchor fastener with vibration isolation Springs, back draft damper (wherever required) bird screen at both sides and rated Motor with class-F insulation. Motor shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply with starter panel.
Back draft Damper : Where required for system design roof-mounted fan shall be equipped with a rattle-free back draft damper to prevent air from re entering the fan when fan is not in operation, thus sealing completely in closed position. Damper shall be chatter proof under all conditions.
Note:-These fans would be connected to the fire alarm system & BMS System of the building and would start automatically in case of Fire
1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second)
2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second)
3. Fan motor shall meet IE3 or above standard as per IS-12615
5. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm.
6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted.
Capacity 4000 CFM, SP 20 mm wg
Capacity 5000 CFM, SP 20 mm wg
Capacity 6000 CFM, SP 25 mm wg
Capacity 7000 CFM, SP 25 mm wg
Capacity 8000 CFM, SP 25 mm wg
Capacity 9000 CFM, SP 30 mm wg
Capacity 10,000 CFM, SP 30 mm wg
Capacity 11,000 CFM, SP 30 mm wg
Capacity 12,000 CFM, SP 30 mm wg
Capacity 14,000 CFM, SP 30 mm wg
Capacity 15,000 CFM, SP 30 mm wg
Capacity 16,000 CFM, SP 35 mm wg
Capacity 18,000 CFM, SP 35 mm wg
Capacity 20,000 CFM, SP 35 mm wg
Capacity 22,500 CFM, SP 35 mm wg
Capacity 25,000 CFM, SP 35 mm wg
ROOF MOUNTED FAN (SMOKE EXTRACT/FRESH AIR )
Supply, installation testing & commissioning of Roof mounted smoke extract /Fresh Air fan shall be vertical discharge type, direct driven as shown on drawing and required to meet system design requirement., complete with impeller , motor and weather proof aluminum housing Roof mounted smoke fans should be able to withstand the temperature of 250deg C/2hr with starter panel. The certifications should be in accordance with UL standards and as per specifications. Structural frame with blank-off sheet, anchor fastener with vibration isolation Springs.
a. Housing: shall be constructed of 16 gauge steel sheet. The housing shall have an adjustable flange to facilitate installation and shall be especially adapted to receive fan, motor, and drive. The, motor shall be installed in ventilated water proof housing outside the air stream. The discharge cowl shall be hinged along one edge for easy access to motor and drive, for inspection and maintenance. The entire assembly shall be weatherproof and raised from the roof terrace sufficiently to prevent down flow of rain water accumulated on the terrace. 18 gauge galvanized steel mesh bird screen shall be provided on all discharge cowls around the outlet area.
b. Fans : shall be propeller type as required, designed for maximum efficiency, minimum turbulence and quiet operation. Fan shall be statically and dynamically balanced.
c. Motor : shall be energy efficient IE 3 ( as per IS 12615) squirrel-cage, totally- enclosed, fan cooled, standard frame, constant speed, continuous duty, single winding, suitable for 415±10% volts, 50 cycles, 3 phase AC power supply, provided with class `F’ insulation. designed for quiet operation and IE3 efficient. Bearings shall be designed for vertical mounting. Motor name-plate horse-power shall be such that the motor shall not be overloaded in the entire range of rated speed. Motor and fan assembly shall be easily removable. Motor power supply characteristic and maximum speed shall be as specified for propeller fans with starter panel.
d. Fan Bearings : shall be heavy duty, self-aligning sleeve/ball bearings designed for thrust load and sealed for grease retention.
e. Back draft Damper : Where required for system design roof-mounted fan shall be equipped with a rattle-free back draft damper to prevent air from re entering the fan when fan is not in operation, thus sealing completely in closed position. Damper shall be chatter proof under all conditions.
f. Vibration Isolation :The motor and fan assembly shall be isolated from the base with vibration isolators.
Noise level shall be 80 dBA @ 1m Distance.
Note:-These fans would be connected to the fire alarm system & BMS System of the building and would start automatically in case of Fire
Capacity 5000 CFM, SP 25 mm wg
Capacity 6000 CFM, SP 25 mm wg
CABINET TYPE CENTRIFUGAL FAN :
Supply, installation, testing, commissioning of direct driven double skin Cabinet type centrifugal fan with 25mm thick PUF insulation fan section consist of Centrifugal Fan, forward curve, with radial tip double wheel, double inlet, consisting of motor, drive arrangement, aluminum common frame for fan and motor, cushy foot mounting, aluminum base frame for the unit, VCD on the outlet of fan, filter and accessories as per specification and drawing complete with 25mm thick five layer GI wire mesh filter, Structural frame with blank-off sheet, anchor fastener with vibration isolation Springs and starter panel.
The motor shall be spark-proof. The starter panel shall be provided with in-built timer to switch OFF the fan after a preset time (say 300 seconds) once triggered
The cost include with approximate 10 RM suitable cabling between starter & unit.
Note:-These fans would be connected to the fire alarm system/BMS System of the building and would start automatically in case of Fire
1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second)
2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second)
5000 CFM with 40 mm static Pressure
6000 CFM with 40 mm static Pressure
7500 CFM with 40 mm static Pressure
8000 CFM with 40 mm static Pressure
9000 CFM with 40 mm static Pressure
10000 CFM with 40 mm static Pressure
11000 CFM with 40 mm static Pressure
12000 CFM with 40 mm static Pressure
14000 CFM with 40 mm static Pressure
15000 CFM with 40 mm static Pressure
CABINET TYPE CENTRIFUGAL FAN (Fire Rated) :
Supply, installation, testing, commissioning of direct driven double skin Cabinet type centrifugal fan with 25mm thick PUF insulation fan section consist of Centrifugal Fan, forward curve, with radial tip double wheel, double inlet, consisting of motor, drive arrangement, aluminum common frame for fan and motor, cushy foot mounting, aluminum base frame for the unit, VCD on the outlet of fan, filter and accessories as per specification and drawing complete with 25mm thick five layer GI wire mesh filter, Structural frame with blank-off sheet, anchor fastener with vibration isolation Springs and starter panel.
The motor shall be spark-proof. The starter panel shall be provided with in-built timer to switch OFF the fan after a preset time (say 300 seconds) once triggered
Fan and motor shall be fire rated to 250 Deg C for 2 hours or as indicated in the specifications
Note:-These fans would be connected to the fire alarm system/BMS System of the building and would start automatically in case of Fire
1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second)
2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second)
1000 CFM with 15 mm static Pressure
INLINE FAN (Ceiling suspended)
Supply, installation, testing, commissioning of Inline fan with vibration isolators & speed regulator, complete as per specification and drawing. The Motor shall be suitable to run on 1 phase/50 hz/ 220 v electrical power.
400 CFM with 10 mm static Pressure
500 CFM with 12 mm static Pressure
600 CFM with 12 mm static Pressure
700 CFM with 12 mm static Pressure
800 CFM with 12 mm static Pressure
900 CFM with 12 mm static Pressure
1000 CFM with 15 mm static Pressure
1100 CFM with 15 mm static Pressure
1200 CFM with 15 mm static Pressure
1400 CFM with 15 mm static Pressure
1500 CFM with 15 mm static Pressure
2000 CFM with 15 mm static Pressure
PROPELLER FAN (Mettalic Type):
Supply, installation, testing and commissioning of wall mounted Propeller type heavy duty exhaust Fan of metallic construction complete with speed regulator, bird screen, gravity louvers, vibration isolators, required cable, plug & other accessories compete as required, suitable for single phase, 240± 10 volts, 50Hz AC. supply of following capacities:
300 mm sweep dia (900 RPM)
380 mm sweep dia (900 RPM)
450 mm sweep dia (900 RPM)
ABS PLASTIC TYPE PROPELLER FAN
Supply, installation, testing & commissioning of Wall mounted Propeller type exhaust air fans of high grade ABS plastic construction complete with electric motor suitable for operation on 230 V+ 10%,50 Hz, 1 phase AC supply fitted with speed regulator, mountings frames, louvers and bird screen, required cable & plug to connect with socket etc. complete as required of following capacities.
200 mm sweep dia (900 RPM)
250 mm sweep dia (900 RPM)
300 mm sweep dia (900 RPM)
CARBON MONO-OXIDE SENSOR
CO Sensors along with PLC controller and suitable cable as per specifications with IP-65 protection. CO sensors having range 0 to 300 ppm with analog output 4 to 20mA or 0 to 10 V DC output signal. These CO sensors and controller are interface with fire alarm panel/BMS (as available). All CO Sensors specification meets with NBC-16 requirements & Specification.
PLC Controller
CO Sensors
HYDROGEN (H2) SENSOR
H2 Sensor for Battery room with IP-65 protection, long life, fast response with high accuracy and integrated with BMS Panel. Hydrogen level in Battery room as per Fire Code and CE/UL approved. These H2 sensors and controller are interface with fire alarm panel/BMS (as available) & Specification.
Response Time<10 sec
Output-4-20mA or 2-10V, Supply-24V DC
Controller
H2Sensors
AIR SCRUBBER (DRY TYPE)
The unit shall provide efficiency of 90% or better for single pass base on ASHRAE test method at flow rates of 800 – 1500 CFM per module (supported by sample test report by a US laboratory).
Housing shall be constructed with minimum 1.4 mm thick galvanized steel sheet (16 gauge) with reinforced structure and powder coated to protect against rust and corrosion. It shall have a hinged door for cell access, located one side to the unit. The door shall be gasketed to prevent air leakage. There shall be a safety interlock switch to cut off primary supply when the access door is opened.
Ionizing-Collecting Cell(s) shall be of one-piece construction consisting of a series of repelling and collection plates. Both repelling and collector plates shall be aluminum alloy material, rigidly retained in place with tubular spacers and tie rods. Each plate shall be corrugated, perpendicular to airflow direction. Each cell shall weigh not more than 16 kg with at least 9 ionizing wires.
Ionizing electrodes / wires shall be of tungsten material, rigidly supported both vertically and laterally. Ionizing electrode to ground electrode spacing shall be 1.0” (25 mm). High voltage support insulators shall be of Teflon material for dielectric strength.
Each Ionizing / Collecting Cell shall be capable of handling up to 3000 cmh of air. There shall be one to four such ionizing / collecting cells per module. Each module shall handle up to 3000 CMH, 6000 CMH, 9000 CMH and 12000 CMH per module respectively. Multiple units of the same or different modules may be needed to handle higher air flow capacities.
Sound level at 3mt distance at 1.5mt Height from fan outlet shall not be more than 80dbA.
Power supplies shall be 100% solid state, operate on 240 VAC, 50 HZ, 1 Phase input and provide a dual high voltage output of 12 to 13 KVDC for the ionizer and 6.0 to 6.5 KVDC for the collector, in normal operation conditions. Current output at the high tension shall be 12mA. A maximum power output for the solid-state power supply shall be from 50 watts to up to 150 watts to maintain the specified collection efficiency.
The rated efficiency shall be up to 95% based on the NIOSH 5026 OIL MIST TEST. Past on situ test reports of 90% to 95% of the said test method must be submitted.
10,000 CFM with 60 mm static Pressure
25,000 CFM with 65 mm static Pressure
AIR WASHER :
Supply, Installation, Testing & Commissioning of factory fabricated Double Skinned Air-washer unit floor mounted type fabricated out of extruded aluminum section with 0.8mm pre-plasticized /pre-coated Galvanized steel sheet outside & 0.8 mm plain Galvanized steel sheet inside with blower, blower section and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply. Air washer having minimum 90% efficiency with consisting of centrifugal fan, mounting arrangements, mentalistic vibration isolation, belt drive arrangement, VCD, distribution headers, access door, pump, stainless steel water tank, suction screen, impregnated cellulose paper fills, nylon prefilter, GI ‘B’ class piping & associated works, quick fill, makeup & drain connections with butterfly & float valves etc. complete as per specifications & drawings. The unit shall be fire retardant, water proof double flexible connection at fan outlet and with starter panel.
Filters section shall incorporate synthetic washable filters of at least 50 mm thickness in suitable aluminum frame. Velocity of air across the fillers shall not exceed 500 fpm (2.5m/s).
8000 CFM with 50 mm static Pressure
20000 CFM with 50 mm static Pressure
CHILLED /CONDENSOR/HOT WATER PIPING & VALVES
Supply, installation, testing and commissioning of bare chilled / Hot water piping of M.S 'Heavy' , complete with fittings like elbows, tees, reducers, bends, MS flanges, supports, welding, painting etc. but excluding valves as required conforming to IS:1239 / 3589 & technical specification. All Chilled Water and hot water pipes are insulated with Class-O closed cell elastometric nitrile rubber tubular Insulation having duly laminated aluminum foil of mat finish as given below or in technical specification.
Chilled Water Pipe (With Nitrile Rubber tubular Insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class ‘O’ insulation applied by suitable rubber based adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Insulation duly laminated with aluminum foil of mat finish as given below or in technical specification
Note:-The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes up to 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
500 mm dia (32 mm Thick NR)
450 mm dia (32 mm Thick NR)
400 mm dia (32 mm Thick NR)
350 mm dia (32 mm Thick NR)
300 mm dia (32 mm Thick NR)
250 mm dia (32 mm Thick NR)
200 mm dia (32 mm Thick NR)
150 mm dia (32 mm Thick NR)
125 mm dia (32 mm Thick NR)
100 mm dia (32 mm Thick NR)
80 mm dia (32 mm Thick NR)
65 mm dia (32 mm Thick NR)
50 mm dia (32 mm Thick NR)
40 mm dia (32 mm Thick NR)
32 mm dia (19 mm Thick NR)
25 mm dia (19 mm Thick NR)
Pressure Independent Balancing Cum Two Way Control Valve
Supply, Installation, Testing and Commissioning of Pressure Independent Balancing Cum Two way Control valve having differential pressure controller & self- balancing for chilled water with electrical actuator. Pressure independent type dynamic balancing valve integrated with 2 way modualating control valves in a single body. Body material shall be brass or cast steel. All working parts like stem & spring shall be in SS. Balancing should be done only in Valve not in actuator so that at any given condition of failure, balancing is not lost and easily accessible. The actuator versions should be directly mounting on valves without any adjustments. All the electrical actuator shall be operated through 24 V AC and should be modulated through control signals 0…10 V DC, 4….20 mA, through BMS or display thermostats. The actuators should have stroke position indication and manual override mean to manual open and close the actuators when commissioning. Maximum close off pressure shall not be less than 6 Bar for up to 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.
Electronic modulating actuator working on 2-10 V DC, 4- 20 mA electric signal. The minimum close off Pressure of actuator must be 1.5 times shut off head of pump as per specifications of following sizes:
100 mm Dia, Maximum 220 GPM
80 mm Dia, Maximum 132 GPM
65 mm Dia, Maximum 72 GPM
50 mm Dia, Maximum 50 GPM
40 mm Dia, Maximum 26 GPM
32 mm Dia, Maximum 17 GPM
25 mm Dia, Maximum 8 GPM
Motorised Butterfly Valves
Supply, installation, testing and commissioning of motorised on / off butterfly valves with modulating motor in return chilled & condenser water line of each chiller, condenser & cooling tower operated through BMS & of following sizes:
250 mm dia (For Chillers)
100 mm dia (For Hot Water Generator)
BUTTERFLY VALVE (MANUAL)
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified
250 mm dia (32 mm Thick NR)
150 mm dia (32 mm Thick NR)
100 mm dia (32 mm Thick NR)
80 mm dia (32 mm Thick NR)
65 mm dia (32 mm Thick NR)
50 mm dia (32 mm Thick NR)
40 mm dia (32 mm Thick NR)
Brass Ball Valves With Y-Strainer
PN 16 pressure rating for chilled water/hot water circulation as specified
25 mm dia
32 mm dia
Automatic Balancing Valves
Supply, installation, testing and commissioning of automatic balancing valves in return chilled and condenser water line of each chiller, condenser and cooling tower as per tender specification & of following sizes:
250 mm dia (For Chillers) With Insulation
100 mm dia (For Hot Water Generator)
80 mm dia
BALANCING VALVE
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
125 mm dia (32 mm Thick NR)
100 mm dia (32 mm Thick NR)
80 mm dia (32 mm Thick NR)
65 mm dia (32 mm Thick NR)
50 mm dia (32 mm Thick NR)
40 mm dia (32 mm Thick NR)
NON RETURN VALVE
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.
250 mm dia (32 mm Thick NR)
150 mm dia (32 mm Thick NR)
125 mm dia (32 mm Thick NR)
100 mm dia (32 mm Thick NR)
80 mm dia (32 mm Thick NR)
65 mm dia (32 mm Thick NR)
Y-STRAINER
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
250 mm dia (32 mm Thick NR)
150 mm dia (32 mm Thick NR)
125 mm dia (32 mm Thick NR)
100 mm dia (32 mm Thick NR)
80 mm dia (32 mm Thick NR)
65 mm dia (32 mm Thick NR)
50 mm dia (32 mm Thick NR)
40 mm dia (32 mm Thick NR)
Auto Air Vent Valve
15 mm dia
19 mm dia
25 mm dia
PRESSURE GAUGE (ALL SS TYPE)
THERMOMETERS
Providing & fixing in position the mercury in glass industrial type thermometers Thermometers of approved make & shall be of mercury in steel type with range suitable for the temperature services. It should be installed in the thermowells as explained in the tender specifications.
FLOW SWITCH
Supplying, fixing, testing and commissioning of SG Iron Body flow switch with necessary control wiring and interlocking at Chilled Water Pump
DRAIN VALVES
Supply, Installation, Testing & Commissioning for Drain Valves in dirt legs complete with nipples as per specifications.
50 mm Dia
40 mm Dia
32 mm Dia
25 mm Dia
CONDENSOR WATER PIPES
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. But excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.
Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes up to 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
All outdoor condenser water piping shall be treated with Zinc Cromate Primer plus two coats of Epoxy Paints.
500 mm dia
450 mm dia
400 mm dia
300 mm dia
250 mm dia
200 mm dia
150 mm dia
125 mm dia
100 mm dia
Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.
BUTTERFLY VALVE
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 300 mm dia
NON RETURN VALVE
NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified. 300 mm dia
MOTORIZED BUTTERFLY VALVE
Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting up to 10V DC and up to 20mA electric signal and providing similar transduced feedback output to control system as required.
300 mm dia
150 mm dia
Automatic Balancing Valves
Supply, installation, testing and commissioning of automatic balancing valves in return chilled and condenser water line of each chiller, condenser and cooling tower as per tender specification & of following sizes:
300 mm dia
Pot Strainer
500 mm dia
DRAIN VALVES
Supply, Installation, Testing & Commissioning for Drain Valves in dirt legs complete with nipples as per specifications.
50 mm Dia
40 mm Dia
25 mm Dia
GI Condensate Drain Piping
Supply, installation, testing and commissioning of condensate drain water piping of GI 'Medium' class complete with fittings like elbows, tees, reducers, bends, MS flanges, supports, welding, painting etc. as required conforming to tender specifications and of following sizes. Pipe Shall be duly insulated with 6 mm thick closed cell expanded polythene.
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
UPVC Condensate Drain Piping
Supply,installation,testing and commissioning of UPVC drain piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell expanded polythene.
DUCTING,INSULATION,DAMPER, GRILLE & DIFFUSER
Supply, fabrication, installation & testing of Aluminium sheet metal ducting duly polysulphide sealed complete with Splitter Damper, vanes etc. as required for OT and as per ISI specifications and as per approved shop drawings.
Supply. Installation, testing and commissioning of insulation on the surface of the duct with duly laminated aluminum foil of mat finish closed cell nitrile rubber (Class 'O' ) with suitable adhesive, as per specifications and drawings. The Joints shall be sealed with 50mm wide and 3 mm thick self adhesive nitrile rubber tape Insulation. The rates shall include all materials of the insulation and labour works with adhesive, complete as required and specifications.
The joint between the ducts shall be done by means of polymer “flange / slide-in channel” system to prevent air leakages. Turning vanes, elbows and reducers to be considered as part of supply of ducts. Ducts shall be supported by cable supports / GI slotted channels with threaded rods. Internal Stiffeners shall be used to prevent bulging of ducts for the sizes above 800 mm.
0.80 MM (22 Gauge ) With 32mm Insulation
1.00 MM (20 Gauge ) With 32mm Insulation
1.25 MM (18 Gauge) With 32mm Insulation
FACTORY FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS
Supply. Installation, testing and commissioning of factory fabricated Galvanized Steel (GSS) Sheet metal ducts with flanges, inbuilt sealant, gasket, supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.
Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
0.63 MM (24 Gauge )
0.80 MM (22 Gauge )
1.00 MM (20 Gauge )
1.25 MM (18 Gauge) Plenum
SITE FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS
Supply, Fabrication, installation and testing of Galvanized Steel (GS) sheet metal ducts & finally applying fire rated paint as per BS 476 Part 24 (Site FABRICATED DUCTS For Connection /Plenum etc.) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, etc., as per specifications.
Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006
0.63 MM (24 Gauge )
0.80 MM (22 Gauge )
1.00 MM (20 Gauge )
1.25 MM (18 Gauge)
FIRE RATED FACTORY FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS
Supply. Installation, testing and commissioning of Fire rated sheet metal ducts shall be fabricated from Lock Forming Quality grade prime galvanized steel sheet with flanges complete with supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Supporting distance shall not exceed 1.2 Mtr with 6mm thick fire retardant gasket suitable for 250 deg C 2 hr shall be used in duct joints along with fire sealants. Suitable access doors shall be provided at every 3m. The rates shall include all materials of the duct and labor for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.
All fire rated duct, smoke exhaust ducts shall be quoted with flame bar BWII or equivalent to achieve the required fire rating, also all the related accessories gaskets shall be suitable for the required fire rating.
Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
1.25 MM (18 Gauge) Plenum & Exhaust Duct
Duct Insulation
Supply. Installation, testing and commissioning of insulation on the surface of the duct with duly laminated aluminum foil (26G) of mat finish closed cell nitrile rubber (Class 'O' ) with suitable adhesive, as per specifications and drawings. The Joints shall be sealed with 50mm wide and 3 mm thick self adhesive nitrile rubber tape Insulation. The rates shall include all materials of the insulation and labour works with adhesive, complete as required and specifications.
AHU ROOM ACCOUSTIC LINING
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications. 50 mm thick
Duct Acoustic Lining
Supply and fixing of acoustic lining of supply air duct and plenum with thick Engineered Nitrile Rubber open cell foam having a Noise Reduction Coefficient of 0.55 with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Supply. Installation, testing and commissioning of G.I construction Duct/ Volume control Dampers for Controlling the Airflow in Ducts with neoprene rubber gaskets,nuts, Bolts, Centrifugals Linkages, Flanges etc. as per specification.
MOTRIZED VOLUME CONTROL DAMPER
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room.
Motorized (ON-OFF Type) duct mounted GI volume control damper
Motorized (ON-OFF Type) duct mounted GI volume control Actuator
BACK DRAFT DAMPERS
Supply, Installation, testing and commissioning of 18 Gauge G.I construction Back draft Dampers for Controlling the recirculation of air with neoprene rubber gaskets,nuts, Bolts, Centrifugals Linkages, Flanges etc. as per specification. Louvres shall be made powder coated extruded aluminum.
PRESSURE RELIEF DAMPERS
Supply,. Installation, testing and commissioning of 18 Gauge aluminum alloy extrusions with welded/cleated frames Pressure Relief Dampers for Controlling the Excess pressure up to 60pa with neoprene rubber gaskets,nuts, Bolts, Centrifugals Linkages, Flanges etc. as per specification. Louvres shall be made powder coated extruded aluminum with suitable thickness.
GRILLES AND DIFFUSERS
Supply. Installation, testing and commissioning of powder coated extruded aluminum sections grills as per specification.
Grilles with Dampers
Supply. Installation, testing and commissioning of powder coated extruded aluminum section grills with dampers for supply air terminal for air-conditioning as per specification.
Diffusers
Supply. Installation, testing and commissioning of powder coated extruded aluminum square diffusers with antismudge ring and removable core.
Supply air with dampers
Return air without damper
Flexible Duct
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Supply. Installation, testing and commissioning of thermal flexible aluminum duct of following sizes duly supported at regular interval as per site requirement & spefications. 200 mm
Slot Diffusers
Supply. Installation, testing and commissioning of slot diffusers with/without damper as specified below and as per specification.
3-Slot Diffuser
2-Slot Diffuser
Linear Grille
Supply. Installation, testing and commissioning of powder coated extruded aluminum Linear Grille.
Exhaust/Fresh Air Louvers
Supply. Installation, testing and commissioning of exhaust air/fresh air louvers of powder coated extruded aluminum construction with bird screen, minimum 80 mm deep.
Fire Damper with Spring and Fusible Link
Supplying, installation, testing and commissioning of Fusible Link type fire and smoke dampers of 18 gauge GI sheet construction suitable for 120 minute fire rating.
Fire Dampers & Actuator
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Duct/Wall mounted multi blade, motorised fire & smoke dampers with spring return actuator. The damper shall be of at least 1.5 hr. fire rating and actuated with the help of 24 V electric actuator excluding. The damper shall be as per UL listed UL 555; 1995 and CBRI approved. The damper shall be constructed out of 16G galvanised steel sheet & as per specification with Control Cable to Potential Free Contact for tripping of AHU fan motor.
Supply, installation, testing and commissioning of Motorised Spring Return Actuator for devices up to 0.8 sq. meter with control panel & temperature sensor.
Fire Damper
Actuator
Under Deck Insulation of Exposed Roof
Providing and Fixing Underdeck Insulation with 50 mm thick with closed cell Nitrile Rubber with prelaminated Aluminum foil on one side having a low stable k value of 0.035 k.cal/hr.m at 10.C and minimum density of 40-55 ± 3 kg/cum.The R-value should be as per ECBC Code. 50mm
ELECTRICAL WORKS
ISOLATOR FOR OUTDOOR UNIT
Supply, Installation, Testing & Commissioning of following Switchgears as an Isolator in IP-65 rated in power coated 16 SWG sheet steel enclosure .
40A 4P MCCB(25 KA)
63A 4P MCCB(25 KA)
100A 4P MCCB(25 KA)
CUBICAL PANEL BOARD FOR HIGH SIDE EQUIPMENTS
Design, Manufacture, Supplying, Transport to the site, Receiving, Unloading, Shifting to various locations, handling, assembling, installation in correct aligned position, grouting with dash fasteners, GI nuts-bolts, testing and commissioning of Totally Type Tested Panels (Form-4B construction) complying to IEC:61439 -1/2 cubical with Internal arc withstand of 50kA for 0.3 second and minimum impact resistance IK10 as per IEC:62262 with each compartment front unbreakable glazed door cover and back solid door. The degree of protection of minimum IP:42 for indoor and IP:65 for outdoor use. Panels shall be tested for an Impulse Withstand Voltage of 12kV. Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply system bolted fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plate, bottom base channel of MS section not less than 100mmx 50mmx50mmx 5mm thick for Main L.T. Panel and capacitor panels and 40mmx25mmx25mmx 5mm thick plates for MDB/MCC and SDBs etc.
Including cleaning & finishing complete, SMC bus bar supports, with short circuit withstand capacity of minimum 50kA for 1 Sec., fabrication shall be done in transportable sections and all front and back doors shall be hinged type and earth with frame, Entire panel shall have a common copper continuous earth bar of size 40mm x 6mm or as specified below at the rear with 2 Nos. earth stud each side, solid inter connections from main bus bar to switch gears up to cable alley with required size. bus bars and insulated control wiring with suitable size of FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates in two half, incl. providing following switch gears :-
Panels will be powder coating (60-80micron as per IS:13871 for indoor and 90-100 micron for outdoor), include one size higher terminal block in cable alley and interconnecting wires between bus bars and terminals via MCB. All Bus-Bar alley and relay compartments shall be provide fully automatic control thermostat with strip heater.
4# 600TR Water Cooled Centrifugal Chiller-4Nos (3 Working+1Stand by)
4# Primary Pumps ( 3W+1S)(40 HP EACH)
5# Secondary pumps (3W+2S) (75 HP EACH)
3# 250 kW Hot Water Generator(2w+1s)
2# Hot Water Pumps (2W+1S)(20 HP EACH)
4# CDW Pumps (3W+1S)(100 HP EACH)
4# 700TR Cooling Tower ( 3W+1S) (4 #15.0 HP each )
INCOMER
Incomers –2 Nos 2500 Amps 4P ACB 50 kA for O/C , S/C& E/F protection ,reverse power relay- trip & RS485 Port, cable connection on one side and Busbar connection on the other side.
INDICATING PANEL
Provide 1nos phase indicating lamps LED each backed up with fuse and switch.
Provide 2500/5a CT CI-1,15VA operated Digital Ammeter for all in-comers and outgoings including C/T's.
Two numbers indicating lamps LED on each incoming and outgoing feeder for indicating the status of feeder.
One number indicating lamp LED on each incoming and outgoing feeder for indicating that the feeder has tripped due to fault condition.
1 No. Power factor meter
1 No. Digital type energy meter.
Break Control Switch (T-N-C)
Control Fuse Base
BUS COUPLER
Incomers –1 Nos 2500 Amps 4P ACB 50 kA for O/C , S/C& E/F protection trip & RS485 Port, cable connection on one side and Busbar connection on the other side.
BUSBARS
Sections of 3Nos x 3200 Amps TPN bus bar chamber of suitable lengths with Aluminium bus bars. All bus bars and interconnections shall be of suitable size Al strips. Current density of Al shall not be more than 1.0 Amps/ sq.mm cross sectional area of Bus Bar
Incomer and 3Nos x2500 A EDO 4P ACB bus coupler shall be mechanically & electrically interlocked to avoid paralleling of the two supplies.
OUTGOING
4# 600TR Water Cooled Centrifugal Chiller-4Nos (3 Working+1Stand by)
1000A 4P ACB of suitable rating with overload, short circuit protection, on /off /trip indication light with control MCB. MCCB Shall be 50 KA (ICU=ICS) SET - 06 ( Extra 2 Nos Spare)
4# Primary Pumps ( 3W+1S)(40 HP EACH)
5# Secondary pumps (3W+2S) (75 HP EACH)
3# 250 kW Hot Water Generator(2w+1s)
630A 4P ACB of suitable rating with overload, short circuit protection, on /off /trip indication light with control MCB. MCCB Shall be 50 KA (ICU=ICS) SET - 04 (1Nos Spare )
2# Hot Water Pumps (2W+1S)(20 HP EACH)
4# CDW Pumps (3W+1S)(100 HP EACH)
4# 700TR Cooling Tower ( 3W+1S) (4 #15.0 HP each )
POWER CABLING
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender.
A) Power cabling (XLPE insulated Aluminum / Copper conductor as given below armoured / unarmoured cables of 1.1 KV Grade) including cable end termination with brass compression glands & lugs etc. as per specification.
Note:- Power cable with earthing shall be made available near indoor / outdoor units. Only termination into HVAC equipment's (Indoor & Outdoor) shall be done by HVAC Contractor.
3.5 Cx 25 Sqmm Al Conductor
3.5 Cx 35 Sqmm Al Conductor
3.5 Cx 50 Sqmm Al Conductor
3.5 Cx 70 Sqmm Al Conductor
3.5 C x 95 Sq. mm Al Conductor
3.5 C x 120 Sq. mm Al Conductor
3.5 C x 150 Sq. mm Al Conductor
3.5 C x 185 Sq. mm Al Conductor
3.5 C x 240 Sq. mm Al Conductor
3.5 C x 300 Sq. mm Al Conductor
Supply and laying ,testing and commissioning of following sizes of Copper conductor control cables with PVC conduit & fixing clamps and effecting proper connections to equipment etc. of following sizes :
4C x 16 Sq. mm Copper Conductor (Armoured)
4C x 10 Sq. mm Copper Conductor (Armoured)
4C x 6 Sq. mm Copper Conductor (Armoured)
4C x 4 Sq. mm Copper Conductor (Armoured)
3C x 1.5 sq. mm Copper Conductor (unarmoured)
3C x 2.5 sq. mm Copper Conductor (unarmoured)
3C x 4 sq. mm Copper Conductor (unarmoured)
3C x 10 sq. mm Copper Conductor (Armoured)
3C x 16 sq. mm Copper Conductor (Armoured)
GI CABLE TRAY
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
EARTHING STRIP/WIRES
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply & laying 25x5mm GI strip at 0.5mt below ground as strip earth electrode including connection/terminating with GI nut,bolt,spring,washer etc. as required.)jointing shall be done by overlapping &with 2sets of brass nuts bolt spring washer spaced at 50mm) 25mm x5mm
INTERNAL ELECTRICAL WORK
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
CIRCUIT / SUBMAIN WIRING
2x1.5 sq mm + 1x1.5 sq mm earth wire
2x2.5 sq mm + 1x2.5 sq mm earth wire
2x6 sq mm + 1x6 sq mm earth wire.
2x10 sq mm + 1x6 sq mm earth wire.
2x16 sq mm + 1x6 sq mm earth wire.
4x2.5 sq mm + 2x2.5 sq mm earth wire
4x6 sq mm + 2x6 sq mm earth wire.
4x10 sq mm + 2x6 sq mm earth wire.
4x16 sq mm + 2x6 sq mm earth wire.
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required.
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
CIRCUIT / SUBMAIN WIRING
2x1.5 sq mm + 1x1.5 sq mm earth wire
2x2.5 sq mm + 1x2.5 sq mm earth wire
2x6 sq mm + 1x6 sq mm earth wire.
2x10 sq mm + 1x6 sq mm earth wire.
2x16 sq mm + 1x6 sq mm earth wire.
4x2.5 sq mm + 2x2.5 sq mm earth wire
4x6 sq mm + 2x6 sq mm earth wire.
4x10 sq mm + 2x6 sq mm earth wire.
4x16 sq mm + 2x6 sq mm earth wire.
Supplying and drawing Following pair 0.5 mm dia FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20mm dia
25mm dia
32mm dia
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps one way switch
15/16 amp one way switch
5/6 amp 3 pin socket outlet
5/16 amp 6 pin socket outlet
Telephone Socket Outlet
TV anteena Socket Outlet
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet.
4/5 Module (78mm x140mm x 50mm)
6 Module (78mmX205mmx50mm)
8/9 Module (78mmX230mmx60mm)
12 Module (135mmX205mmx60mm)
Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing Ding dong sound call bell single phase, 230 volts, complete as required.
Installation, testing and commissioning of pre wired fluorescent fitting / Compact fluorescent fitting off all type complete with all accessories and tube etc directly / wall including connection with 1.5 sq.mm FR PVC insulatted. copper conductor single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required.
Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan, making good the damage, connection, testing, commissioning etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (For UPS Supply)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
20mm dia
25mm dia
Supply & drawing following sizes of FR PVC insulated copper conductor single core cables in existing surface/recessed steel / PVC conduit including dismantling as required.
2 x 1.5 sq.mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 Way Double Door
12 Way Double Door
Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 Way (4+18), Double Door Horizontal Type
8 Way (4+24), Double Door Horizontal Type
Supplying and fixing following ways surface / recess mounting Vertical type 415 Volts TPN MCB distribution board, of sheet steel dust protected duly power painted inclusive of 200 Amps tinned copper bus bar common, neutral link, earth bar, din bar, for mounting MCB's (But without MCB's and incomer) as required. ( Note:- Vertical Type MCB TP DB is normally used where 3phase outlets are required.
8 Way (4+18), Double Door Vertical Type
12 Way (4+24), Double Door Vertical Type
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required.
6 / 32 Amp Single Pole
40 Amp DP
50/63 Amp DP
6/32 Amp TPN
40 Amp TPN
50/63 Amp TPN
Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing of following rating double pole ( Single pole & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required.
Providing and fixing M.V. danger Notice plate of 200mm x 150 mm of made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird
Providing and fixing H.T. danger Notice plate of 250mm x 200 mm of made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird
Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required.
For 10 way, Double door SPN MCBDB
For 14 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415V, on surface/ recess, complete with testing and commissioning etc. as required.
For 6 way, Double door TPN MCBDB
For 8way, Double door TPN MCBDB
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required.
Providing and fixing 50 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing of lighting conductor finial made of 25 mm dia 300 mm long, GI tube having single prong at top with 85 mm dia 6mm thick G.I Base plate including hole etc. as required
Providing and fixing GI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. ( for Horizental Run)
Providing and fixing GI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. ( for Vertical Run)
Providing and fixing testing Jointing made of 20mmx 3mm thick G.I Strip 125 mm Long. With 4 nos of G.I bolts. Nuts chuck nuts and spring washers etc. as required
Providing and Laying G.I tape 32mm x 6mm from earth electrode directoly in ground as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
INSPECTION CHAMBER:
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
2 run of cable
3 run of cable
Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming to IS-7098. (Part-I).
3.5 core, 300 sq.mm.
3.5 core, 240 sq.mm.
3.5 core, 185 sq.mm.
3.5 core, 150 sq.mm.
3.5 core, 120 sq.mm.
3.5 core, 95 sq.mm.
3.5 core, 70 sq.mm.
3.5 core, 50 sq.mm.
3.5 core, 35 sq.mm.
4 core, 16 sq.mm.
4 core, 10 sq.mm.
4 core, 6 sq.mm.
2 core, 16 sq.mm.
2 core, 10 sq.mm.
2 core, 6 sq.mm.
Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor PVC insulated cable including termination complete as required in existing cable tray.
1C x 240 sq.mm PVC Insulated cu wire including termination etc.
1C x 25 sq.mm PVC Insulated cu wire including termination etc.
1C x 16 sq.mm PVC Insulated cu wire including termination etc.
Supply & Laying of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming to relevant IS.
4 core, 2.5 sq.mm.
10 core, 2.5 sq.mm.
12 core, 2.5 sq.mm.
33 KV H.T. CABLE:
Supplying & Laying of 33 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required. 3C x 300 Sqmm, 33 KV XLPE
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with cable tie)
Above 35 sq. mm and upto 95 sq. mm (clamped with cable tie)
Above 95 sq. mm and upto 185 sq. mm (clamped with cable tie)
Above 185 sq. mm and upto 400 sq. mm (clamped with cable tie)
Laying of one number additional PILCA / PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of size exceeding 120 sqmm but not exceeding 400 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 x 6 sq. mm (19mm)
2 X 10 sq. mm (19mm)
2 X 16 sq. mm (22mm)
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (50mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
4 X 10 sq. mm (25mm) including (4x6mm)
4 X 16 sq. mm (28mm)
11 KV END TERMINATION:
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3C x 300 Sqmm, 11KV XLPE
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm atnominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.
400 A 25kA SC for 1 sec
630 A 50kA SC for 1 sec
1000 A 50kA SC for 1 sec
1250 A 50kA SC for 1 sec
3200 A 50kA SC for 1 sec
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required
125 A 15kA SC for 1 sec (including 100A)
200 A 25kA SC for 1 sec (Including 160A)
250 A 30kA SC for 1 sec
400 A 35kA SC for 1 sec (Including 300A)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes cubicle panel, making connections, etc. as required.
100 A, 35 KA,TPMCCB
200 A,36KA,FPMCCB
250 A,36KA,FPMCCB
400 A,35KA,FPMCCB
Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with rovision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required
630 A 50kA SC for 1 sec
1000 A 50kA SC for 1 sec
1250 A 50kA SC for 1 sec
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes cubicle panel, making connections, etc. as required. 630 A,50KA,FPMCCB
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Testing & Commissioning of following End Feed Unit housing fabricated out of 14G CRCA powder coated (as approved) sheet steel for the Rising Mains fitted with following ACB. The End Feed Unit should complete with solid aluminium links of rated capacity of ACB to Rising Mains. The End Feed Unit should be complete with suitable size of glands plate for incoming cables. All MCCB / ACB shall have Ics value of 50 KA. Each end feed unit shall have a set of 3 nos. phase LED Type indicating lights with control fuses.
1000A FP MDO ACB, 50 KA
1250A FP MDO ACB, 50 KA
Supply, erection, testing and commissioning of following sizes of TV splitter of aluminium die cast body in suitable size of G.I. Box. 4 way
Supply, erection, testing and commissioning of following co-axial cable in existing conduit. RG-11
Supply & installation of 32 Amp 3 phase, 415 volt, 50 Hz water tight (IP-55) socket outlet with interlocking switch complete with all fixing accessories.
Supply & installation of 32 Amp single phase 240 Volt, 50 Hz, water tight (IP-55) socket outlet with interlocking switch complete with all the fixing accessories as below.
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification.
100 mm wide x 40 mm deep.
150 mm wide x 40 mm deep.
200 mm wide x 40 mm deep.
250 mm wide x 40 mm deep.
300 mm wide x 40 mm deep.
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification.
150 mm wide x 50 mm deep.
200 mm wide x 50 mm deep.
250 mm wide x 50 mm deep.
300 mm wide x 50 mm deep.
350 mm wide x 50 mm deep.
Supply, Installation, Testing & Commissioning of Earthing Junction Box size - 400mm x 300mm x 80mm made out of 16 SWG CRCA sheet with seven tank process & powder coating, earthing link (32mm x 6mm copper strip) front door with glass as complete as required.
Supply & Fixing of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006.
Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.
Supplying & Placing of First aid box as approved by St.John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963 etc as reqd.
Supplying & Installation of Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English) etc. as reqd
FIRE ALARM SYSTEM (ADDRESSABLE TYPE) AND PA SYSTEM
Ten Loop Panel.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector acclimate type sensetive level (0.524%) OVS/ft. complete with mounting base complete as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. (75 DBA @3 mtr. & 75CD flashing)
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supply, installation, testing and commissioning of addressable monitor module complete as per specification.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. Same make as of Fire Alarm System
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. Same make as of Fire Alarm System
Supply Installation, Testing & Commissioning of fire fighter main console at control room including power supply and accessories.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 480 Watt, supply complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmm
SUPPLY & INSTALLATION OF LIGHT FIXTURES & FANS
SITC of following rating recess / surface mounted LED round / square shape down light luminarie with pressure die cast housing for single phase supply voltage Luminarie shall be confirm to IS: 10322 part -5 / section -2 or IEC :62722 withh all neccesary accessories as required.
12W LED Round Down Light
15 / 16 W LED Round Down Light
18 /20 W LED Round Down Light
18 /20 W LED Round Down Light
2' x 2' LED Panel Light
Bulk Head fitting with 9/10Watt LED.
S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required.
10/12 W LED Tube Light
20/22 W LED Tube Light
SITC of 300 mm (12") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required.
Supply Installation, Testing & Commissioning of following sizes ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard (up to 30cm) with 1.5 sq.mm FR PVC insulated copper wire suitable for 230V 50 Hz, Single phase supply etc. complete as required. 1200 mm ( 48") BLDC 5 Star rating 32W Ceiling Fan
Supply of 31W Watt, surface Type, LED Bed Head light fixture, having minimum system lumen output of 100 Lumen / watt complete as requried. (Make : Wipro Cat. No.LW04-411-XXX-57-WS, Bed Head Light)
S.I.T.C of Following rating LED Street Lighting luminare with pressure die cast housing and toughened glass cover (IP 66 protection ) in existing pole / pipe for supply voltage 100-270 AC 50Hz Luminare shall be confirm to IS :10322 part 5/ section-3 and shall be complete with all nessessary accessories as required. 60W LED Street Light
S.I.T.C of Following rating LED Post Top lamp made in die cast aluminium housing with decorative clear / opel acrylic diffuser on existing pipe including connection with 1.5sq.mm coppwr conductor etc all complete as required. 20/25W LED Post top lamp clear
S.I.T.C of Following rating approved make LED Bpllard Fitting with cylindrical shape and inverted cone shape head of height 600 to 850 mm power input -8/9 watt with die cast aluminium housing opel with PC diffuser, IP-65/54 protection, conferming to IS : 10322 part 5 etc all complete as requird. (Excluding Plinth Charge.)
Supplying & installation of 7 mtr. Height Octagonal Hot Dip galvanized pole (BOP. 7030) with top dia 70 mm bottom dia 130 mm & made of 3 mm thick sheet base plate dimensions 200x200x12 mm (LxBxT) including suitable size of foundation bolt all complete as required (without Arm).
1m Single Arm Suitable for 70MM Top
UPS SYSTEM
Supply, Installation, Testing & Commissioing of 250 KVA UPS in paralleling mode at 0.99 input power factor with SNMP card, compatible for BMS connectivity on backnet/MODBUS, Inbuilt Isolation transformer as per specification given in the document with following broad features.
THD(i) shall be less than 3% in the entire loading range.
UPS shall carry design output at 40 deg.
Shall have soft start and hold of for incoming supply.
Invertor capability to supply 150% load for 5 sec.
Three Phase Input and Three Phase Output. (Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.)
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
Battery shall be external type with rack and suitable for 30 minute backup on 100% load.
Suitable size of copper cable between UPS and battery bank shall be provided
UPS shall be compatible for 6 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS.
UPS described as above
Supply, fitting, fixing, testing and installation of 30 KVA, ON Line UPS three phase input and three phase out put power system of in put voltage range 360V/380/V/400V/485V AC , Frequency range 40 HZ to 60 Hz, +/- 10% and out put voltage range 415V +/-1%, AC frequency range, 50Hz, +/-1% poower factor 0,8/3.1, Harmonic distrortion -< 2% THD (Linear Load): 5% THD (Non- Liniear Load) along with required Batteries, Battery Stand, UPS Box Battery Lead etc as required.
UPS shall carry design output at 40 deg.
Shall have soft start and hold of for incoming supply.
Invertor capability to supply 150% load for 5 sec.
SNMP card, compatible for BMS connectivity on backnet/MODBUS, Inbuilt Isolation transforme.
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
Battery shall be external type with rack and suitable for 90 minute backup on 100% load.
Suitable size of copper cable between UPS and battery bank shall be provided
UPS shall be compatible for 3 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS.
SITC of MS Battery Rack suitable for 30 to 35 UPS Battery Installation.
SITC of 72 nos. 65 AH Flat type Sealed Maitanace Free (SMF) Battery with 24 months replacement warranty. IS:1652:1991. (VAH Required minimum 56160 for 50 KVA UPS (65AH x 72 Nos. x 12V = 56160 VAH)
Total cost of 1 Set 30 KVA UPS, Batteries & Accessories (A+B+C)
DATA, TELEPHONE SYSTEM INCLUDING ACTIVE COMPONENTS
Supply, Installation, Testing & Commissioning of Patch Panel Cat 6 U/FTP 24 Port- Loaded as per technical specification.
Supply, Installation, Testing & Commissioning of Patch Panel Cat 6 U/FTP 48 Port- Loaded as per technical specification.
Supply, Installation, Testing & Commissioning of Patch Cord Cat 6 U/FTP 3 feet as per technical specification.
Supply, Installation, Testing & Commissioning of Patch Cord Cat 6 U/FTP 7 feet as per technical specification.
Supply, Installation, Testing, Commissioning of Cat 6, 10G, U/FTP, Information Outlet including G.I. Box and modular cover plate as per technical specification.
Supply , Installtion , Testing and comissioning of 15U wall mount rack with fans , 2 cable managers, satationary shelf , 2 Nos of hardware pkts as per technical specification.
Supply, Installation, Testing & Commissioning of Network Rack 42 U with below included: Network Rack 800W x 2000H x 800D, Top cover with 4 x cutout, 2 x cutout for cable entry. Bottom cover with 4 x cutout for cable entry. All cutouts blanked with Plastic caps. 2 pairs, 42 U 19" Profile Type angle,Front & etc. complete as per technical specification.
Supply, Installation, Testing & Commissioning of 24 port 10/100/1000Mbps, 4SFP module, L-2 Switch, POE as per technical specifications.
Supply, Installation, Testing & Commissioning of 48 port 10/100/1000Mbps, 4 SFP Module, L-2 Switch, POE as per technical specifications.
Supply, Installation, Testing & Commissioning of IP Based voice Communication System with 04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility , 500 IP users License ,01 Nos. IP Operator Console, 30 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, - Redundant server in active-Active mode as per technical specification.
Supply, Installation, Testing & Commissioning of Type 1 IP Phone . Graphic LCD display with backlight 3 user accounts with multi-line appearance keys Local and company-wide phone directories.
Supply, Installation, Testing & Commissioning of Type Basic Phone account , Full duplex speaker phone, .
Supply, Installation, Testing & Commissioning of Core Switch 24 1Gb/10GBASE-T ports, 2 10Gb/40Gb QSFP+ ports, 4 10Gb/25Gb/40Gb/50Gb/100Gb capable QSFP28 ports, 2 populated power supplies slots, with suitabe fan module slots, supporting RIP, OSPF, VRRP L3 protocols from day one as per technical specification.
Supply, Installation, Testing & Commissioning of SFP+ 10GBASE-SR 10 Gigabit Ethernet Optics, 850 nm for up to 300 m,transmission on multimode fiber (MMF).
Supply, Installation, Testing & Commissioning of 6 Core OM4 Multimode Fiber Cable as per technical specification.
Supply, Installation, Testing & Commissioning of 24 Port LC multimode loaded LIU.
Supply , Installtion , Testing and comissioning of 48 port loaded LIU for core switch to access switch connectivity over fiber.
Supply, Installation, Testing & Commissioning of LC - LC Fiber patch cord OM4, 3 Mtrs.
Supply, Installation, Testing & Commissioning of 6 Core, Single Mode, OS2 as complete as required.
Supply, Installation, Testing & Commissioning of wifi Access point as complete as required.
IP CCTV SYSTEM
Supplying, installation, testing & commissioning of 4MP or better IP Network TDN Low-Light IR Rugged Dome Camera, 1/3" CMOS or better, 4MP (2592 x 1520) @ 20fps or better, triple stream at various resolution up to 25fps, Min. Illumination required 0.01 lux @ F2.0 (color), 0 Lux IR On, 4 IR LEDs Smart IR with upto 30m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 55db, Shutter Speed 1 - 1/100,000; Adavance Video Compression technology such as H.265 & H.264 High Profile & MJPEG , Triple stream, , Stream Encryption, 256GB SD card support, PoE (802.3 af) and 12V DC, Max 6W, IP 66/67, IK 10 vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant, UL.
Supplying, installation, testing & commissioning of 4MP IP Network TDN Low-Light IR Rugged Bullet Camera, 1/2.7" CMOS or better, 4MP (2592 x 1944) @ 25fps or better, triple stream at various resolution up to 25fps, Min. Illumination required 0.008 lux @ F1.6 (color), 0 Lux IR On, 4 IR LEDs Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video Compression technology such as H.265 & H.264 High Profile & MJPEG , Triple stream, 2.7 to 13.5mm 5X motorized focus & zoom lens, Field of View FoV H:85°-24°, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence Video Analytics : Motion Detection, Face Detection, 4Privacy Mask, 4 Region Of Intreset, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 256GB SD card support, PoE and 12V DC, Max 6W, IP 66/67, IK 10 vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant, UL.
Supplying, installation, testing & commissioning of Outdoor 1/2.8 inch CMOS 2MP or better, IR PTZ Camera ; 40x Optical Zoom & 16x Digital Zoom, tripple stream; IR distance: 200 meter or better; Lens 4 -175mm Motorized Auto focus zoom lens; Memory card slot: Min 256GB support. Minimum Illumination- Sense up on- Color: 0.001 lux color, B/W: 0 lux IR On, WDR 120dB, Edge Video Analysis Video Motion Detection, Intrusion, Lioter, Counter & Tampering, 3DNR, BLC, HLC, White Balance, EIS, Defog, Mechanical switchable IR filter (Auto ICR), Pan Range 360° continuous, Tilt Range -10° to 90°, Pan/Tilt Modes - Pan: 0.1°/s - 180°/s; Tilt: 0.1°/s - 90°/s, Presets 200, Preset Accuracy 0.25 Deg, 16 Patrol & Tours, Alarm I/O - 2In/2Out, 2-Way Audio- 1/1 Channel In/Out, 256GB Memory card slot, 4 individually configurable privacy masks, 4 Region of Interest, POE+ or 24VAC 3A for indoor/Outdoor application, IP66/67, IK 10 ; Certifications: ONVIF Profile S/G/T compliant, UL.
Supplying, installation, testing & commissioning of IP Network Video Storage Manager Server Channel Network Video Storage Manager Server - NSM shall have Intel® Xeon Silver 4210R, 2.2 GHz or better, Mnimum 32GB RAM, 1+1 750W hot plug redundant power supply, OS drive: 2 x 240 GB in RAID 1; 12 field upgrade up to 20 TB SATA/SAS hard drive options for Video Recording, Data RAID Level: 0, 1, 5, 6, 10. NIC card 4 x 1GbE supporting network throughput of 800 MBPS, Windows Server 2019 R2 64- bit/Windows10 64-Bit IOT Operating System, Microsoft SQL Server/Express 2019. NSM Shall support upto 128 Cameras @ 1080P, 25fps, 09 Remote Client Licenses inbuilt, Web Clients, Monitor Layout up to 4x4, Digital Signature for Video Clip, Continous & Motion Based Recording options, up to 8X forawrd & backward palyback, Playback search as date/time timeline, time jump FWD/REV, bookmarks, calendar, preview, film strip, event search and SMART Motion Search as a min. NVR shall be ONVIF S/G/T certified and liested on ONVIF Website. NVR shall Support Two -Way Audio with cameras equiped with Microphone & Speaker. Each NSM shall be offered with 128TB Video Stoarge for Recording for 30 days.
Supply, Installation, Testing and commissioning of Managable 24 port Switch with Power on Ethernet (PoE) enabled, 10/100, RJ45 Access ports with PoE complete as required.
Supply, installation, testing and commissioning of of 16 TB HDD all accessories complete as required.
Supply installation and commissioning of 48 inch LED monitor for disply of camera.
SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM
Supplying installation testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including all the required accessories like Solar PV module, Grid Tie invertor, arrey junction box, cabling & wiring, earthing, surge protection device, FRLSame structure for mounting of solar panel. The cell shall be poly crystaline silicon cells of 6 inch each and module efficiency shall be more than 17%. Solar module shall have linear output warranty with degradation not exceeding 0.7% FRLSom 2nd Year onwards. Minimum 80% power output must be assured at end of 25 years. The FRLSont glass of solar module shall be low iron tempered glass ARC type. Termination box shall be Thermo-plastic, IP 67 or better, UV resistant with built-in-bypass. The nominal power of a single PV module shall be minimum 540 Wp or higher. Positive power tolerance modules only to be used. RF identification tag for each solar module shall be provided inside the module and must be able to withstand environmental conditions. The solar panel shall be complience of IEC 61215, IEC 61730 certified by TUV Rheinland / UL. The solar panel shall be installed as per BOQ & detailed technical specification.
AUTOMATIC FIRE DETECTION GAS SUPPRESSION SYSTEM
For Main LT Panel, Lift Panel & Fire Fighting
Supply, fixing, testing and commissioning of Supply, fixing, testing and commissioning of Automatic Linear pneumatic Tube Detection based FK 5-1-12 Pre-Engineered System for Electrical Panels (consisting of the following components.) Approved Makes - Firemech / Ceasefire / Tyco / Honeywell
4.0 KG UL Listed Cylinder Automatic Pre-Engineered System filled with Clean Agent FK 5-1-12, Fitted with DLP Valve mounted on Cylinder Push-In-Connector for Tube, Mounting Bracket, End of Line Adopter and UL Listed Low Pressure Switch for Monitoring System Activation.
9.0 KG UL Listed Cylinder Automatic Pre-Engineered System filled with Clean Agent FK 5-1-12, Fitted with DLP Valve mounted on Cylinder Push-In-Connector for Tube, Mounting Bracket, End of Line Adopter and UL Listed Low Pressure Switch for Monitoring System Activation.
UL Listed Linear Pneumatic Heat Detection Tube with all necessary fittings & supports, HR Grade,UV Protected, MultiLayered, Made of Special Modified Polyamide Material, Inner diameter 4mm, Outer Diameter 6MM, Operating Pressure 15 8Bar, Maximum Pressure 30 Bar at maximum Temperature of +65 Degree C, Pressurized.
Master Control Unit with Audio Visual Alarm with wiring to make complete system operational. The Control Panel should have provision for integration with Fire Alarm/SCADA/BMS System (Supply to be provide by the end client at 220 Volt AC).
For Server Room
Supply, fixing, testing and commissioning of UL Listed & PESO Approved High Pressure Seamless BIS 7285 approved Cylinders with contact Pressure Gauge & PESO Approved Valve, Including all fittings and accessories with Respective size mounting bracket. The cylinder size to be considered respective to filling density allowed by OEM
140 Ltr (Master Cylinder)
140 Ltr (Slave Cylinder)
FK 5-1-12 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions.
Master Cylinder Kit complete Comprising all mandatory accessories : Electric Actuator, Manual Release Device, Discharge Hose - DN 50, Manifold Check Valve, Reset Toolkit, Cylinder Strap, Caution Advisory Signage’s, System should include Electric Control Head operated electrically from the detection and control system with a manual actuator and Wire Braided Flexible Rubber Hose with Elbow and connectors complete assembly to Connect FK 5-1-12 Cylinder Assembly Discharge outlet with Discharge Pipe or Discharge Manifold. On any displacement of solenoid valve, master cylinder kit shall be able to notify the fault by audio/visual mean.
Slave Cylinder Kit Complete Comprising all mandatory Accessories: Pneumatic Release Device, Actuation Hose, Discharge Hose - DN 50, Manifold Check Valve, Cylinder Straps & Caution Advisory Signage’s to Connect FK 5-1-12 Slave Cylinders.
Discharge Nozzles to Discharge FK 5-1-12 Gas in the Hazard Area as hydraulic calculation and flow rate required in 180 Deg/360 Deg Discharge Pattern.
Supply, fixing, testing and commissioning of 'Discharge Pipe with Support and Fittings, CS Seamless to ASTM A-106 Schedule 40/50. along with threaded fittings of 3000# conforming to ANSI B 16.11
Supply, fixing, testing and commissioning of 2 Zone Microprocessor Based Automatic Gas Extinguishing Panel with 2 Batteries. Two Zone automatic extinguishing panel should be CE Approved and Operates on 220-240 VAC, 10%, 50 Hz, 100W. Consisting Smoke Detector/Heat Detector/Multi Detector, Manual Release Switch. The Manual release switch module shall comply with the requirements of BS7273-1/UL, Abort Switch. The Abort switch module shall comply with the requirements of BS7273-1/UL, Hooter with Strobe Light, Response Indicator & Discharge And Pre Discharge Indicator., along with Loop Cable (2C x1.5mm) Armoured.(Fire Alarm System with respect to Room size)
ACCESS CONTROL SYSTEM
Supply ,Installation ,Testing & Commossioning of 4 Door 4 reader access control panel with onboard 32 Bit RISC ARM CPU, 8MB flash memory, shall support up to 30000 card user, 100000 event transactions, TCP/IP, the panel should have inbuilt 4 GB SD memory card to take mirror image of device configuration. data shall support standard Wiegand readers, Access Control panel should have MODBUS connectivity to integrate the panel with BMS (Building Management System), with metal enclosure & inbuilt power supply, facility of din-rail mounting should available. capable to integrate with IP/CCTV & NVR for access event alerts, Inbuilt door interlocking facility, SNMP alerts facility, Low battery and AC fail alert facility & reader Tamper detection alert facility should available.
Supply ,Installation ,Testing & Commossioning of 2 Door 2 reader access control panel with onboard 32 Bit RISC ARM CPU, 8MB flash memory, shall support up to 50000 card user, 200000 event transactions, TCP/IP, the panel should have inbuilt 4 GB SD memory card to take mirror image of device configuration. data shall support standard Wiegand readers, Access Control panel should have MODBUS connectivity to integrate the panel with BMS (Building Management System), with metal enclosure & inbuilt power supply, facility of din-rail mounting should available. capable to integrate with IP/CCTV & NVR for access event alerts, Inbuilt door interlocking facility, SNMP alerts facility, Low battery and AC fail alert facility & reader Tamper detection alert facility should available .
Supply, installation, testing and commissioning Short Range (up to 9 cm ) Smart Card Reader For Exit of Lift Access Doors , tripod/Flap barrier- Entry & Exit (doors) as per the specification.
Supply, installation, testing and commissioning of contactless Clamshell 2K /2Application Area Smart Card suitable for Access Door as per the specification.
Supply, installation, testing and commissioning Access Control System Server Software consisting of Access Control system , Alarm Document , Alarm management , All these along with high end security features consist in single package as per specification. Approved.
Supply, Installation, testing & commissioning of Single Leaf Electro Magnetic Lock of Suitable Capacity(Min 600 lbs) as per specification .Approved.
Single Door Leaf
Double Door Leaf
Supply and Laying of of 8 Core x 0.2 sq mm multi strand, copper, unarmored shielded Cable as per specification (between the every card readers & the access controllers)
Power Supply- Supply, Installation , testing and commissioning of 12 V SMPS DC Power Supply Unit, highly regulated and spikes free terminal voltage and heavy sourcing current for regulated terminal voltage.
Magnetic Contact- Supply, Installation, Testing and commissioning of Magnetic Contact.
Supply , Installation , Testing and commissioning of Single Front Facia Plate consisting of Soft Touch Push Buttons Emergency Exit Door Release and indicator LED to show the door status.
Supply Installation testing and Commissioning of Biometric 50,000 templates (1: N) and 800,000 transaction records 3.5 in color TFT display Internal Camera supports capture and display (or storage) of the user’s image Standard backup battery Optional integrated proximity or smart card reader Built-in USB port allows for manual data transfer when the network isn’t available 8 user-defined function keys Relay contacts for access control applications Multi language support Audible and Visual indications for acceptance/ rejection of valid/invalid fingers SDK is available for OEM customers and software developers (Approved Make- Timewatch / / Timewatch) (for attendence purpose).
AV SYSTEM
GROUND FLOOR RECEPTION
Display System
Supply Installation Testing and Commissioning of Fine Pitch Active LED Wall of 2.5 mm pixel pitch of Size 6.60 m x 2.03 m, Resolution: 2640 x 810, Pixel Density (pixels/m²): 1,60,000, Cabinet Material: Die-casting Aluminum, Refresh Rate: 3840 Hz, Viewing Angle (H × V): 160° x 150°, IP Rating (Front/Rear): IP50/IP50, LED Controller to manage the LED screen, Certifications: CE, FCC, CB, RoHS, REACH with Mechanical Structure to mount the LED screen.
Supply Installation Testing and Commissioning of Fine Pitch Active LED Wall of 2.5 mm pixel pitch of Size: 2.40 m x 1.35 m, Resolution: 960 x 540, Pixel Density (pixels/m²): 1,60,000, Cabinet Material: Die-casting Aluminum, Refresh Rate: 3840 Hz, Viewing Angle (H × V): 160° x 150°, IP Rating (Front/Rear): IP50/IP50, LED Controller to manage the LED screen, Certifications: CE, FCC, CB, RoHS, REACH with Mechanical Structure to mount the LED screen.
Switching System
Supply Installation testing and Commissioning of Display and Projection system for MultiFormat Matri Switcher shall support full featured 2x USB-C connectivity at 4K, with 2x HDMI2.0 and USB 3.1 input. Supports HDMI 4K signal formats (4K UHD @60Hz RGB 4:4:4, up to 18 Gbps).Shall support built in control features, with 2x RS-232, TCP/IP, IR, 6x GPIO port and audio de-embedding functionality. It should have HDCP2.2, built in oscilloscope, advanced EDID manager for real time diagnostics of signal. Occupancy sensor connection (with 24V power supply). Must have 4x USB 3.1 hosting for peripherals device. 60 watt charging over single USB-C cable along with audio and video transmission; etc all complete.
Cable Cubby
Supply Installation testing and Commissioning of Cable Cubby Enclousre with HDMI, USB-C Connectivity, Flush mounted with all required accessories etc all complete.
Cables. & Accessories
Supply Installation testing and Commissioning of High Speaed HDMI Cable - 1 Meter with 4K UHD Support etc all comlete.
Supply Installation testing and Commissioning of High Speaed HDMI Cable - 5 Meter with 4K UHD Support etc all comlete.
Supply Installation testing and Commissioning of USB Type–C to USB-C Cable: 3 Feet etc. all complete.
Supply Installation testing and Commissioning of Type A Male to Type A Female USB cable - 3 Meter.
MEETING ROOM -12 PAX
Display System
Supply Installation Testing and Commissioning of DLP / LCD laser projector, LCD Panel: 0.64" * 3 BrightEra LCD Panel Brightness: 5300 Lumens, Center lumens- 5800 Lumens, Resolution: 69,12,000 (192012003) Pixels, WUXGA (1920*1200) Contrast Ratio: ∞:1 (Infinite) Light Source: Laser Diode Lamp Life: 20,000 Hours Zoom Ratio: Manual (Approx. 1.6X) Throw Ratio: 1.23:1 to 1.97:1 Lens Shift: Manual; Vertical: -35% to +55%; Horizontal: +/- 15% Speaker Output: 16W Keystone Correction: Vertical: +/- 30 degrees; Horizontal: +/- 30 degrees Input Ports: Mini D-sub 15-pin, HDMI (2), HDBaseT, Video In, Audio In, Audio Out Control Ports: RS232, USB Type A, RJ45 Special Features: Reality Creation, Intelligent Settings, Bright View Dimensions: Approx. 422 x 129 x 338 mm (16 5/8 x 5 3/32 x 13 5/16 inches) Weight: Approx. 6.8 kg (15 lb)e.
Supply Installation Testing and Commissioning of Motorized Projection Screen, Image Size: 123 inch diagonal, Fabric: Matt White, Aspect Ratio: 16:10, With Low Voltage Control Module & RF Remote Control etc all complete.
Supply Installation Testing and Commissioning of Wireless presentation platform, BYOD wireless screen sharing, 4K UHD output resolution, No apps, no buttons, Enterprise level security.
Switching System
Supply Installation Testing and Commissioning of Switcher for VGA, DVI-I, HDMI and DisplayPort with Audio embedding, VGA, YPrPb, DVI, HDMI 1.4 and DP 1.1 with analog stereo audio from local inputs or embedded 7.1 HDR audio, Advanced EDID Management, No signal latency, zero frame delay, Pixel Accurate ReclockingSupports HDMI 4K signal formats (4K UHD @30Hz RGB 4:4:4 or @60Hz YUV 4:2:0, up to 9 Gbps).
Cable Cubby
Supply Installation Testing and Commissioning of Cable Cubby Enclousre with HDMI, VGA+Audio, USB-C to HDMI Cable Pass Through, Flush mounted with all required accessories etc all complete
Supply & Laying of following size Cables & Accessories
HDMI Cable
VGA + Audio Cable
USB-C to HDMI Cable
HDMI Cable
Supply Installation Testing and Commissioning of Chairman Unit Compact, attractive, ergonomic design, with LED indicator in the Discussion Device and in head of microphone. Unit shall have integrated Loudspeaker and Built-in headphone socket with output level control,The chairman has a separate microphone button and priority button enable the user to function as the chairperson at a conference or meeting. The chairperson’s microphone shall be activated when the priority button is pressed and held in with Frequency response 200Hz-12.5kHz and Loudspeaker nominal output 72dB SPL.
Supply Installation Testing and Commissioning of Delegate Unit Compact, attractive, ergonomic design, with LED indicator in the Discussion Device and in head of microphone. Unit shall have integrated Loudspeaker and Built-in headphone socket with output level control,Color-coded light-ring indicator in head of microphone: green shall indicate that a request-to-speak has been added to the waiting list; green flashing shall indicate that the participant is first in the waiting list; red shall indicate that the microphone is active with Frequency response 200Hz-12.5kHz and Loudspeaker nominal output 72dB SPL.
Supply Installation Testing and Commissioning of Digital Controller with Plug-and-play functionality for quick and easy connection of Discussion Devices. System control shall have Web browser control to view and manage system settings and loudspeaker and headphone socket for listening to recorded discussions before replaying them to the Floor, or listening to recordings,System controller shall have Built-in Digital Acoustic Feedback Suppression (DAFS) .Controller shall support up to 80 Discussion Devices with Frequency response 200Hz-12.5kHz Max. input (110 db SPL) <0.5% Sample rate 44.1kHz
Supply Installation Testing and Commissioning of two-way, full-range surface mount speaker, LF transducer housed in a fire rated ABS plastic enclosure for extended LF performance down to 75 Hz. Maximum SPL 98.5 dB Sensitivity: 86.5 dB 15W transformer, weather-resistant IP54 as per IEC-60529. Transformer taps: 100 V: 15 W, 7.5 W. Frequency response (-10 dB):75 Hz - 20 kHz.
Supply Installation Testing and Commissioning of 4 mic/line inputs, music source input, single zone Mixer amplfier with 120Watt RMS power, 100V Output, Individual Volume control, Master Bass and Treble Control. Mains power supply 230 VAC ±10%, 50 Hz Frequency response (Line) 80 Hz to 18 kHz (+1/‑3 dB @‑10 dB ref. rated output) Frequency response (Mic.) 80 Hz to 18 kHz (+1/‑3 dB @ ‑10 dB ref. rated output) Distortion <1% @ rated output power, 1 kHz Mic./Line input 4 x
Supply Installation Testing and Commissioning of 19 "Equipment Rack,36 U Made of MS for housing of all above equipment , front lockable glass door, Fan tray fro colling, Caster wheel base , Main Panel with Spike Buster, Indivdual FUSE power supply unit, including all internal wiring/ interconnection as required
Supply Installation Testing and Commissioning of of Handheld Wireless Mic with Cardiod polar pattern for transmitter,Dynamic microphone with Neodymium magnet , Receiver frequency response 80Hz-18kHz,Receiver RF sensitivity < 1.0 µV,Receiver Image rejection>55dB,Receiver Dyanmic range >95dB and receiver having 32 channels possible,Receiver S/N ratio >100dB A,distortion <1 %, Transmitter sensitivity - 3.2 mV/Pa,modulation:+/-40kHz.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
Speaker cable Single pair, 2-core, 1.5 sqmm
MEETING ROOM - 35 PAX
Display System
Supply Installation Testing and Commissioning of DLP / LCD laser projector, LCD Panel: 0.64" * 3 BrightEra LCD Panel Brightness: 5300 Lumens, Center lumens- 5800 Lumens, Resolution: 69,12,000 (192012003) Pixels, WUXGA (1920*1200) Contrast Ratio: ∞:1 (Infinite) Light Source: Laser Diode Lamp Life: 20,000 Hours Zoom Ratio: Manual (Approx. 1.6X) Throw Ratio: 1.23:1 to 1.97:1 Lens Shift: Manual; Vertical: -35% to +55%; Horizontal: +/- 15% Speaker Output: 16W Keystone Correction: Vertical: +/- 30 degrees; Horizontal: +/- 30 degrees Input Ports: Mini D-sub 15-pin, HDMI (2), HDBaseT, Video In, Audio In, Audio Out Control Ports: RS232, USB Type A, RJ45 Special Features: Reality Creation, Intelligent Settings, Bright View Dimensions: Approx. 422 x 129 x 338 mm (16 5/8 x 5 3/32 x 13 5/16 inches) Weight: Approx. 6.8 kg (15 lb) etc all complete.
Supply Installation Testing and Commissioning of Motorized Projection Lift, Aluminium Tubular Motorized Lift with LVC, RF remote, Max Projector size it can take : 600 x 600 x 250 ( W X D X H), , Carrying Weight Capacity : 25 kgs, Drop : 1000 mm ( 1 Mts) etc all complete.
Supply Installation Testing and Commissioning of Motorized Projection Screen, Image Size: 130 inch diagonal, Fabric: Matt White, Aspect Ratio: 16:10, With Low Voltage Control Module & RF Remote Control etc all complete.
Switching System
Supply Installation Testing and Commissioning of Display and Projection system for 6x2 matrix switcher:- 6 video inputs and 2 video outputs - 4 HDMI 1.4 and 2 HD BaseT inputs and 2 independent HDMI outputs. 4K@30Hz, 3D capabilities and HDCP fully supported. should have 4 audio connectors for audio insertion and 2 audio outputs for de-embedding, PoE 48V remote (both inputs and outputs) etc. all complete.
Supply Installation Testing and Commissioning of Multiformat Transmitter, HDMI, VGA, and Audio inputs, Extends VGA, DVI, HDMI 1.4 , Audio, Ethernet, RS-232, up to 120 Meter over one CAT5/6/7 cable, HDMI 1.4, HDCP 1.4 and DVI 1.0 compliant, HDBaseT compatible, Pixel Accurate Reclocking, Supports HDMI 3D signal formats, Bi-directional RS-232 and IR extension (pass-through and control), Supports HDMI 4K signal formats (4K UHD @30Hz RGB 4:4:4 or @60Hz YUV 4:2:0, up to 9 Gbps) etc all complete
Audio System
Supply Installation Testing and Commissioning of Wireless system controller which shall be used as a standalone central control device for wireless connection and control of the Wireless Devices. System controll shall have web interface for system setup, configuration, control and licensing, Remote interfacing, using API to control microphones and 3rd party camera systems.Controller have possiblity to upload customer loog on all devices with Seamless automatic wireless frequency channel switching; up to 44 channels in the 2.4/5 GHz band.
Supply Installation Testing and Commissioning of Charger for five ‘Batteries’ shall include charging status indicators per Battery Pack. It shall be possible to loop-through the mains power supply of 2 to maximum five Chargers (the maximum number of loop-through Chargers is depending on the country mains supply voltage) so that up to 25 Battery Packs can be charged at the same time. A mains power supply, loop-through socket and mounting bracket shall be included with the product
Supply Installation Testing and Commissioning of Handheld Wireless Mic with Cardiod polar pattern for transmitter,Dynamic microphone with Neodymium magnet , Receiver frequency response 80Hz-18kHz,Receiver RF sensitivity < 1.0 µV,Receiver Image rejection>55dB,Receiver Dyanmic range >95dB and receiver having 32 channels possible,Receiver S/N ratio >100dB A,distortion <1 %, Transmitter sensitivity - 3.2 mV/Pa,modulation:+/-40kHz
Supply Installation Testing and Commissioning of Lapel Wireless Mic system that has a min of 14-hour battery life from two AA alkaline batteries. uni-directional polar pattern,condensor microphone ,frequency response 83Hz-18kHz,RF sensitivity < 1.0 Uv,Image rejection>55dB,Dyanmic range >95dB and receiver having 30 channels possible,S/N ratio >100dB A,dynamic range >95db B,distortion <1 %,frequency band:618-634MHz,modulation:+/-40kHz
Supply Installation Testing and Commissioning of 4 mic/line level inputs with AEC, 4 mic/line level outputs, up to 8 channels of configurable USB audio, a 2-channel VoIP interface, and a standard FXO telephone interface, configuration and control for signal routing, mixing, equalization, filtering, and delay
Supply Installation Testing and Commissioning of 8 channel Compact Mixer Class D Amplifier (5 x Mono + 3 x Stereo), Auxiliarys (FX, AUX) : 1 Pre, 1 Post, Class D Amplifier with Frequency Response, -3 dB: 22 Hz to 22 kHz, Crosstalk, 1 kHz Channel to Channel < -78 dB, Max. dual channel output power : > 2 x 550 W @ 4 Ω; > 2 x 320 W @ 8 Ω ,stereo 24/48-bit multi effects processors, > 30 Factory Presets, Tap-Delay, Digital Audio Interface Channels : 2 In / 2 Out, AD/DA Conversion, Sampling Rate : 32/44.1/48 kHz, Phantom power, switchable 48 V DC.
Supply Installation Testing and Commissioning of Dual 4" two-Way Speaker with a Frequency Response(-10dB):- 70Hz-20Khz & Long Term Program Power Handling of ≤ 200W (at Nominal Impedance of 8ohms). The Loudspeaker should have a Sensitivity(1W/1m) of atleast 88dB with a Max. SPL of >112dB. It should have Built in LMT with Power Taps of 7.5/15/30W at70/100V Line. The Sound Dispersion should be 120x70 Degrees or more. The Speaker Should Come with OEM wall Mounting Bracket.
Cable Cubby
Supply Installation Testing and Commissioning of Cable Cubby Enclousre with HDMI, VGA+Audio, Cable Pass Through, Flush mounted with all required accessories etc all complete.
Supply & Laying of following size Cables & Accessories
HDMI Cable
VGA + Audio Cable
CAT6A cable F/UTP (as per actual) etc all complete
Sheilded Audio Cable (as per actual) etc all complete
Connector and Accessories
Supply Installation Testing and Commissioning of Rack Structure 16U Air Cooled AV Equipment Rack with 4 Nos. of Vertical Power Strips, Cantilever Selves, Cable routing perforations, 4 No. of Spin Wheels.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmm
DIESEL GENERATING SET
Supply, testing and Commissioning of Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per lates CPCB norms) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following.
Diesel Engine -
Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system.
Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings :
Start stop switch with key
Water temperature indication
Lubrication oil pressure indication.
Lubrication oil temperature indication.
Battery charging indication
RPM indication
Over speed indication
Low Lube oil trip indication
Engine hours indication
Alternator -
Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for bus duct termination / cable termination as required.
Note : - Alternator should have with all other accessories as per specified in Technical specfications.
Provision of installation of CT's before star point for Differential protection scheme. (DG sets for 2000 KVA only)
6 nos of 3200 / 5 A CT's of PS class of suitable knee point voltage, magnetizing current & resistance.(3 CT's should be installed before star point of alternator) & 1 No. 1600 / 5A CL-5P10 (DG sets for 2000 KVA only)
Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.
Microprocessor based Power command controller (P.C.- 3.3 Jakson or equivalent) suitable for auto / manual synchronization & auto load sharing.
Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete.
Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required.
Exhaust Silencer - Exhaust manifold with residential silencer.
The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system.
Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.
Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.
Supply, Fixing, testing and Commissioning of Exhaust gas piping system of Class `B' MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with mineral wool / rock wool insulation of minimum 75 mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil. The measurement shall be done on the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will go well above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will be confirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval)
450 mm dia (wall thickness - 5.20 mm)
Supply & fixing of SS Bellow of following diameter
450 mm dia
Supply & fabrication of D G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MS angle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation.
SUB- STATION WORK
33 KV HT VCB FOUR BREAKER PANEL BOARD (INDOOR TYPE) (1 INCOMMING + 6 OUTGOING)
Supplying, Installation, Testing & Commissioning of indoor type floor mounted metal clad, 33 KV VCB panel with 6nos VCBs, totally inclosed & fully interlocked, horizontal drawout, horizontal isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and manually closing breaker suitable for use on 33 KV, 3 phase, 50 Hz A.C. supply with short circuit fault level of 1000 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 1250 Amp capacity, breaker featured with mechanical ON/OFF indicator with hand trip device.
Spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switchgears and accessories i/c connections for 3C, 300 sq.mm. XLPE 33 KV cable (cable entry from bottom), end termination with heat shrinkable jointing material etc. as required. (Note - Cost of end termination not included in this item).
a) Incomming - 1 Nos, 1250 Amp, VCB.
d) 1 No - Microprocessor based numericak relay with O/C, E/F and S/C protection.
e) 1 No - set of dual core dual ratio 3 CTs 200/5A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection.
f) 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
g) 1 No. hooter with hooter acceptance and reset push button.
h) 1 No - Red, Yellow & Blue for phase indication.
i) 1 No - Amber for Trip indication.
j) 1 No - Red `ON' Green `OFF'indication.
k) 1 No - Spring charge indication.
l) 1 No - Auto trip indication.
m) 1 No. hooter with hooter acceptance and reset push button.
n) 1 No. master trip relay. ( Electromechanical Type )
o) 1 No.Trip ckt supervision relay. (Electromechanical Type )
a) Outgoing - 6 No, 1250 Amp, VCB.
c) 3 No - Microprocessor based numericak relay with O/C, E/F and S/C protection.
d) 3 No - set of dual core dual ratio 3 CTs 50/5 A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection.
e) 3 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
f) 3 No. hooter with hooter acceptance and reset push button.
g) 3 No - Red, Yellow & Blue for phase indication.
h) 3 No - Amber for Trip indication.
i) 3 No - Red `ON' Green `OFF'indication.
j) 3 No - Spring charge indication.
k) 3 No - Auto trip indication.
l) 3 No. hooter with hooter acceptance and reset push button.
m) 3 No. master trip relay. ( Electromechanical Type )
n) 3 No.Trip ckt supervision relay. (Electromechanical Type )
o) 3 No.auxiliary relay for transformer fault.
p) Power pack.
H.T. Panel described as above
2000 KVA, 33KV/433V OIL TYPE TRANSFORMER
Design, manufacture, supply, installation, testing and commissioning of 2000 KVA, 33 KV /0.433 KV, 3 phase, 6.25 % impedance, 50 Hz delta/star-11 connected, outdoor type, copper wound transformer, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent with ON Load Tap changing arrangement on HV side with Tapping for variations of high voltage from (+) 5% to (-) 15% in steps of 2.5% each with integrated microprocessor based RTCC Panel, bi-directional roller, diagrams & rating plate, Oil temperature indicator, & Winding temperature indicator, Buchholz relay, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.T/L.T cable box etc. complete as per specification. All relays, contacts & CT terminals to be wired upto marshalling box. The Transformer losses should confirm to IS - 1180 Part-1 (2014) with energy efficiency level-1
ELECTRICAL PANEL
Main L.T. Panel with PLC based load manager
All Incoming / bus coupler / Outgoings ACB's shall have inbuilt microprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases. All ACB should have Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature & shall be supplied with adopter terminal connection whose orientation can be changed at site. All ACB shall be supplied with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947
All Incoming / bus coupler / Outgoings ACB's shall have inbuilt current, volatage metering, ZSI (for discrimination) with trip history. All four pole ACB's shall have neutral protection at 50% and 100% . All ACB Shall have common frame till 3200 Amp.
All incoming & outgoing MCCB's shall be microprocessor based with O/L & S/C and E/F protection with inbuilt trip history (Faulty phase, type of fault and interupted Current).
All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement. All TP MCCB shall be with heavy duty solid isolable neutral link. All four pole MCCB's shall have neutral protection at 50% and 100%. All MCCB shall be Single Fram till 250A.
Each section of Panel shall have door opearted light of sufficent lux to illumunate that section & each section of capacitor, buscoupler, transformer and DG incomers shall have exhaust fans for ventilation purpose.
All Energy Analyser / TVM Shall have RS 485 Modbus RTU on board Communication protocol for SCADA communication.
The fault withstanding capacity of panel & its control gear shall be min. 50 KA rms for 1 sec.
The Panel shall have a provision for AUTOMATIC FIRE DETECTION GAS SUPPRESSION flooding system for complete panel of each compartment / section including gas bank of required capacity (Note - Gas Supression flooding sysytem having seperate item).
Note - Complete panel have BMS compactible. Manufacturer shall provide all types of ports, Potential free contact, Aux contactor as required for integration with BMS.
INCOMERS from 5 Nos. 2000 KVA Transformers
1 nos. 3200 AMP. Four Pole, Electrically operated 3 position motorized (220 V AC) drawout type Air Circuit Breaker with all inbuilt protections, with microprocessor based release, over current, earth fault, short circuit, Instantaneous short circuit, closing coil (220 V AC), trip coil (24 V DC), shunt trip release, inbuilt U/V release with LCD / LED display for event history & measurement of current parameters, 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947
The ACB shall be electrically interlocked with the bus coupler, DG incomers and other transformer incomers.
1 nos. 32 amp TP MCCB (50 KA) for OLTC (for each transformer incomer)
1 nos. 630 amp TP MCCB (50 KA) (without U/V protection) for Fire Fighting Pump Panel (As per SLD only)
1 nos. 60 KVAR capacitor bank with 160 amp TP MCCB (50 KA) for each transformer incomer.
Protection releases / relays, Metering & Accessories for each Transformer incomers
Surge Protection Device - Type - 01 (Class - B), 10/350 µ sec. (100 / 25KA)
Over Voltage / Under Voltage relay / release (3 phase) with timer.
Backup earth fault relay.
Restricted earth fault relay.
There shall be a provision : - If REF operates, they send a signal to Upstream HT breaker of Transformer incomer ( in HT Panel) to make it "OFF" for protection of transformer.
Master trip relay.
Trip Circuit Supervison relay.
TNC switch.
1 set of 3 CT's of ratio 3200/5A, Class 1.0 accuracy 15 VA burden for metering.
1 set of 3 CT's of ratio 3200/5A, Class 1.0 accuracy 15 VA burden for APFCR.
1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse.
1 set of 4 CT's of ratio 3200/1A, Class PS for protection.
1 no. CT's of ratio 3200/5A, Class 5P10 for protection.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. (or Dual meter)
Power factor meter.
Frequency meter.
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB.
INCOMERS from 4Nos. 2000 KVA D G sets
1 nos. 3200 AMP. Four Pole, Electrically operated 3 position motorized drawout type Air Circuit Breaker with all inbuilt protections, with microprocessor based releases/relays, over current, earth fault, short circuit, Instantaneous short circuit, shunt trip release, closing coil (220 V AC), trip coil (24 V DC), inbuilt U/V release with LCD / LED display for event history & measurement of current parameters with intruppted current value during fault , 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947
Protection releases / relays, Metering & Accessories for each D G set incomers
Over Voltage / Under Voltage relay / release (3 phase) with timer.
IDMT earth fault relay.
Backup earth fault relay.
Master trip relay.
Trip Circuit Supervison relay.
Reverse power relay.
Voltage restrained over current relay.
TNC switch.
1 Set - 415 /v3 / 110 / v3 Volts PT Class 1.0 accuracy and 100 VA burden along with primary & secondary MCB.
1 set - 3 CTs of ratio : 3200/5A , Class 1.0 accuracy 15 VA each burden for metering.
1 set - 3 CTs of ratio : 3200/5A , Class 5P20 accuracy 20 VA each burden for protection.
2 sets - 3 CT's of ratio : 3200/1A , Class PS for Differential protection scheme (out of which 1 set of 3 CT's shall be provided by the panel manufacturer in loose condition to client or DG manufacturer).
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. (or Dual meter)
Frequency meter.
Power Factor meter.
1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing.
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.
12 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares.
Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop.
Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps.
D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out.
1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (2000 KVA)
Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same.
The ACB shall be electrically interlocked with the bus coupler and Transformer incomers.
BUSCOUPLER
4 no 3200 AMP Four Pole, Electrically operated 3 position motorised (220V AC) drawout type ACB's, closing coil (220V AC), trip coil (24V DC), with 50 KA Breaking Capacity with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:13947-2.
Protection releases / relays, Metering & Accessories for Bus Coupler (s)
Trip circuit supervision relay
TNC switch.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.
The bus coupler shall be electrically interlocked with all incoming ACB's in such a way that at any one time two supply should not get mixed up.
BUSBARS
4000 Amp TPN busbars of aluminium alloy as per SLD.
MICRO PLC FOR AUTO OPERATION OF INCOMER / BUSCOUPLER ACB's.
Auto changeover.
Incomers & Buscouplers switching.
Necessary hardware shall be provided to achieve above functions including micro PLC with real time clock, digital inputs/outputs, MMI with 2 line display, power supply, auxillary relays, PB's indication etc. & software for the above.
Automatic system shall be user friendly and shall have manual override.
BATTERY & BATTERY CHARGER
1 No. 24V, 72AH SMF Battery with suitable battery charger for control supply.
OUTGOING
All outgoing feeder shall be provide with ON / OFF / Trip indication lamp with protection MCB's, Dual Source energy Meter.
04 Nos 2500A FP MDO Air Circuit Breaker (50KA)
03 Nos 1600A FP MDO Air Circuit Breaker (50KA)
02 Nos 1250A FP MDO Air Circuit Breaker (50KA)
02 Nos 630A TP MCCB (50 KA)
01 No 630A FP ON Load Changeover (50 KA)
01 No 400A TP MCCB (50 KA)
03 No 250A TP MCCB (50 KA)
Main L.T. Panel Described as Above.
AUTOMATIC POWER FACTOR CORRECTION PANEL (CAPACITOR PANEL)
supply, installation, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type 750 KVAR A P F C Panel with 14% Detuned LC Filter consisting of 5 /10 / 25 / 50 / 100 KVAR (at 415 Volts rated voltage of bank shall be 525 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 4x, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . Panel shall be of (TTA) Type Tested Assembly with form 4B seperation as per IEC 61439-1 & 2 (TTA panel- L&T-Ti,Schneider-Blokset,Seimens-seipan,ABB-ar2k)
The Panel shall have a provision for AUTOMATIC FIRE DETECTION GAS SUPPRESSION flooding system for complete panel of each compartment / section including gas bank of required capacity (Note - Gas Supression flooding sysytem having seperate item).
All out going MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C release.
AC3 duty contactors should be used for switching individual capacitor banks.
The fault withstanding capacity of panel & its control gear shall be min. 50 KA rms for 1 sec.
Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation purpose.
INCOMING
Incomer circuit breaker has been included in the main panel.
1 set- 3 CTs , ratio 1600 / 5A Class 1.0 accuracy 15 VA burden for metering.
Micro processor based automatic power factor control relay (3 phase) (including power factor meter) in 16 steps for automatic cut off or add on capacitor units to keep the power factor at 0.95 with variation of loads. All associated auxiliary contactors / relays shall be provided with in the scope of work.
Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to indicate On/Off status of capacitor unit.
BUS BARS
2000 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coding and insulated by heat shrinkable sleeves and clips on shrouds for joints.
OUTGOINGS
Capacitor Panel as described above
MAIN ELECTRICAL PANEL
supply, installation, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main Electrical Panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 4X, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable as required. Panel shall be of (TTA) Type Tested Assembly with form 4B seperation as per IEC 61439-1 & 2 (TTA panel- L&T-Ti,Schneider-Blokset,Seimens-seipan,ABB-ar2k)
All Incoming / bus coupler / Outgoings ACB's shall have inbuilt microprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases. All ACB should have Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature & shall be supplied with adopter terminal connection whose orientation can be changed at site. All ACB shall be supplied with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947
All incoming & outgoing MCCB's shall be microprocessor based with O/L & S/C and E/F protection.
All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link.
MAIN ELECTRICAL PANEL
INCOMING
2 Nos. 2500 Amp FP EDO ACB (50 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS COUPLER
1 no 2500 AMP Four Pole, Electrically ACB's,
BUSBAR
3200 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
6 Nos. 1250 Amp TP MDO ACB (50 KA)
2 Nos.630 Amp FP MCCB (50KA)
06 Nos. 400 Amp FP MCCB (50 KA)
10 Nos. 250Amp FP MCCB (50KA)
02 Nos. 200 Amp FP MCCB (50 KA)
02 Nos. 160 Amp FP MCCB (50 KA)
10 Nos. 100 Amp FP MCCB (50 KA)
Panel described as above
MAIN VENTILATION & AHU PANEL
INCOMING
2 Nos. 1250 Amp FP EDO ACB (50 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS COUPLER
1 no 1250 AMP Four Pole, Electrically ACB's,
BUSBAR
1600 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
2 Nos. 1250 Amp FP MDO ACB (50 KA)
4 Nos. 1000 Amp FP MDO ACB (50 KA)
06 Nos. 200 Amp FP MCCB (50 KA)
02 Nos. 160 Amp FP MCCB (50 KA)
04 Nos. 100 Amp FP MCCB (50 KA)
Panel described as above
MAIN ELECTRICAL PANEL-02 ( ACADEMIC BLOCK)
INCOMING
2 Nos. 1250 Amp FP EDO ACB (50 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS COUPLER
1 no 1250 AMP Four Pole, Electrically ACB's,
BUSBAR
1500 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
4 Nos.630 Amp FP MCCB (50KA)
06 Nos. 400 Amp FP MCCB (50 KA)
10 Nos. 250Amp FP MCCB (50KA)
06 Nos. 200 Amp FP MCCB (50 KA)
06 Nos. 160 Amp FP MCCB (50 KA)
10 Nos. 100 Amp FP MCCB (50 KA)
Panel described as above
MAIN ELECTRICAL PANEL-03 ( OPD BLOCK)
INCOMING
2 Nos. 1000 Amp FP EDO ACB (50 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS COUPLER
1 no 1000 AMP Four Pole, Electrically ACB's,
BUSBAR
1250 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
2 Nos.630 Amp FP MCCB (50KA)
06 Nos. 400 Amp FP MCCB (50 KA)
10 Nos. 250Amp FP MCCB (50KA)
06 Nos. 200 Amp FP MCCB (50 KA)
06 Nos. 160 Amp FP MCCB (50 KA)
10 Nos. 100 Amp FP MCCB (50 KA)
Panel described as above
DISTRIBUTION PANEL
L+P PANEL-1 & 2
INCOMING
1 No. 100 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
06 Nos. 25 Amp FP MCB (10 KA)
06 Nos. 40 Amp FP MCB (10 KA)
Panel described as above
L+P PANEL -3 & 4
INCOMING
1 No. 100 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
6 Nos. 25 Amp FP MCB (10 KA)
2 No. 40 Amp FP MCB (10 KA)
8 No. 63 Amp FP MCB (10 KA)
Panel described as above
L+P PANEL -5 to 24
INCOMING
1 No. 200 Amp FP ON LOAD CHANGEOVER MCCB (35 KA)
1 No. 200 Amp FP MCCB (35 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
250 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
06 Nos. 25 Amp FP MCB (10 KA)
04 No. 40 Amp FP MCB (10 KA)
12 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
AHU PANEL -1 & 2
INCOMING
1 No. 200 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
08 No. 25 Amp FP MCB (10 KA)
04 No. 32 Amp FP MCB (10 KA)
04 No. 40 Amp FP MCB (10 KA)
04 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
AHU PANEL -3 to 22
INCOMING
1 No. 200 Amp FP ON LOAD CHANGEOVER MCCB (35 KA)
1 No. 200 Amp FP MCCB (25 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
250 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
04 No. 25 Amp FP MCB (10 KA)
04 No. 32 Amp FP MCB (10 KA)
08 No. 40 Amp FP MCB (10 KA)
06 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
LIFT PANEL-1, 2, 3 & 4
INCOMING
2 No. 400 Amp FP MCCB (35 KA)
1 No Fixed type Automatic transfer switch 400 Amp rating in open frame with live to live transfer time <150ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
500 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
13 Nos.63 Amp FP RCCB (300 mA).
08 Nos.25 Amp FP MCB (10 KA).
04 Nos.40 Amp FP MCB (10 KA).
Panel described as above
PRESSURIZATION PANEL-1, 2, 3 & 4
INCOMING
1 No. 400 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
500 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
20 Nos.63 Amp FP MCB (10 KA).
07 Nos.40 Amp FP MCB (10 KA).
Panel described as above
VENTILATION PANEL
INCOMING
1 No. 200 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
300 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
12 Nos.63 Amp FP MCB (10 KA).
02 Nos.40 Amp FP MCB (10 KA).
Panel described as above
UPS I/C PANEL
INCOMING
2 Nos. 1250 Amp FP EDO ACB (50 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS COUPLER
1 no 1250 AMP Four Pole, Electrically ACB's,
BUSBAR
1600 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
6 Nos. 630 Amp FP MCCB (35 KA).
Panel described as above
UPS O/G PANEL
INCOMING
4 No. 630 Amp FP MCCB (35 KA)
4 Set of phase indicating lamps with Single Pole MCB.
4 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
1600 Amp TPN copper busbar with coloured heat shrinkable sleeve.
OUTGOING
4 Nos. 630Amp FP MCCB (35 KA).
4 Nos. 200Amp FP MCCB (35 KA).
4 Nos. 160Amp FP MCCB (35 KA).
6 Nos. 100Amp FP MCCB (35 KA).
4 Nos. 63Amp FP MCCB (35 KA).
Panel described as above
UPS PANEL-1 & 2
INCOMING
1 No. 100 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
6 Nos.40 Amp FP MCB (10 KA).
02 Nos.25 Amp FP MCB (10 KA).
Panel described as above
UPS PANEL -3 to 24
INCOMING
1 No Fixed type Automatic transfer switch 200 Amp rating in open frame with live to live transfer time <150ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS.
1 No. 200 Amp FP MCCB (35 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
250 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
08 Nos. 40 Amp FP MCB (10 KA)
08 Nos. 63 Amp FP MCB (10 KA)
06 Nos. 63 Amp DP MCB (10 KA)
Panel described as above
EMERGENCY LIGHTING PANEL-1,2 & 3
INCOMING
1 No. 100 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
06 Nos.40 Amp FP MCB (10 KA).
28 Nos.25 Amp FP MCB (10 KA).
Panel described as above
KITCHEN PANEL
INCOMING
1 No. 250 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
250 Amp TPN aluminium busbar.
OUTGOING
08 Nos.63 Amp FP MCB (10 KA).
06 Nos.40 Amp FP MCB (10 KA).
08 Nos.25 Amp FP MCB (10 KA).
16 Nos.63 Amp DP MCB (10 KA).
12 Nos.40 Amp DP MCB (10 KA).
Panel described as above
SMOKE EXTRACTION PANEL-1 To 22
INCOMING
1 No. 200 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
250 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
2 Nos. 32 Amp FP MCB (10 KA)
10 No. 40 Amp FP MCB (10 KA)
04 No. 63 Amp FP MCB (10 KA)
Panel described as above
OT ISOLATION PANEL
INCOMING
1 No. 63 Amp DP ELCB, 30mA.
1 No. 10 KVA, 230V AC medical grade Isolation Transformer.
1 No. 63 Amp DP Miniature Circuit Breaker. (10 KA)
1 No. Sensor and LIM, 0-10mA.
BUS BARS
100 Amp TPN copper busbar with coloured heat shrinkable sleeve.
OUTGOING
16 No. 6-25 Amp SP Miniature Circuit Breaker. (10 KA)
OT Isolation Panel described as above
LAUNDARY PANEL
INCOMING
1 No. 160 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
10 Nos.63 Amp FP MCB (10 KA).
07 Nos.40 Amp FP MCB (10 KA).
Panel described as above
CSSD PANEL
INCOMING
1 No. 250 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
250 Amp TPN aluminium busbar.
OUTGOING
09 Nos.63 Amp FP MCB (10 KA).
06 Nos.63 Amp FP MCB (10 KA).
Panel described as above
UPS O/G PANEL FOR ACADEMIC BLOCK
INCOMING
2 No. 630 Amp FP MCCB (35 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
1250 Amp TPN copper busbar with coloured heat shrinkable sleeve.
OUTGOING
2 Nos. 200Amp FP MCCB (35 KA).
10 Nos. 160Amp FP MCCB (35 KA).
12 Nos. 100Amp FP MCCB (35 KA).
4 Nos. 63Amp FP MCCB (35 KA).
Panel described as above
UPS O/G PANEL FOR OPD BLOCK
INCOMING
2 No. 160 Amp FP MCCB (35 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
300 Amp TPN copper busbar with coloured heat shrinkable sleeve.
OUTGOING
2 Nos. 200Amp FP MCCB (35 KA).
8 Nos. 160Amp FP MCCB (35 KA).
10 Nos. 100Amp FP MCCB (35 KA).
4 Nos. 63Amp FP MCCB (35 KA).
Panel described as above
EXTERNAL LIGHTING PANEL (OUTDOOR TYPE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker (35 KA) with 100 Amp 4 Pole Contactor & Timer.
1 Set of phase indicating lamps.
1 Set of ON/OFF indicating lamps with SP MCB.
BUS BARS
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
08 Nos. 25 Amp DP MCB (10 KA)
03 Nos. 40 Amp DP MCB (10 KA)
Panel described as above
FUEL HANDLING EQUIPMENT
Supply, Installation, Testing & Commissioning of 25 KL capacity mild steel horizontal cylindrical underground HSD tank (2.5M dia & 5.5M length) with shell 6mm and end plate 10mm thick suitable for underground installation complete with manhole accessories, fittings, piping inside the tank Decanting hose, bucket filter, foot valve etc. with paint with inside surface scrapped clean. Tank will be tested at works under hydrostatic pressure of 5 psi before being painted with two coats of Red Oxide Primer as required as per specifications.
Supply, fixing, testing and commissioning of M.S. heavy class ERW piping (Class-C) conforming to IS : l239 with necessary clamps, supports, anti vibration mountings, hangers and fittings such as bends, tees, reducers etc. painted as per specifications:
80 mm dia
40 mm dia
25 mm dia
VALVES & STRAINERS
Supply, Fixing and Testing of following valves, strainers, in the H.S.D. Fuel Handling System piping complete with companion flanges, nut bolts, gaskets, supports and painted etc. as per specifications :
Ball valves :
80mm dia.
40mm dia.
25mm dia.
Non return valves :-
40mm dia
Y-strainers :-
40mm dia.
80mm dia.
Supply, Laying, Testing & Commissioning of 1 No. 40mm dia M.S. heavy class ERW piping (Class-C) conforming to IS : 1239 complete with fittings such as bends, tees, reducer sets on surface/hume pipe or directly in ground including excavation, sand cushioning, 4 mm PYPCOT protective covering and refilling the trench etc. as required. In Ground / On surface
Supply and erection of canopy type M.S.Structure made out of 40mm medium class M.S. pipe (Class-B), 25 x 25 x 3 mm angle iron frame work and 14 SWG GI Sheet. Structure shall be grouted in C.C. 1:2:4 foundation for hanging 4 Nos. 9 litre each fire fighting buckets including providing buckets with two coats of anticorrosive paints etc. complete as required.
Supply & erection of 3 HP Flame Proof positive displacement type HSD pump inside the fuel tank yard having mechanical seal complete with all accessories, fixing on M.S. channel including making earthing as required.
110 LPM, Suction head not less than 3.5 m
Supply and fixing of flow meter for diesel line as required with Flow rate 10.3 to 11 mcu/hr
80mm dia.
25mm dia.
Supply, Installation, Testing & Commissioning of 16A TP Flame Proof out door type isolator switch, M.S. Stand, earthing etc complete as required.
PLUMBING WORKS
SANITARY INSTALLATIONS
Supplying , fitting and fixing vitreous white glazed earthen ware I.W.C of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I 'p' trap 15 liters C.I.pull and let go flushing cistren of names or other I.S.S. equivalent make , complete with all fitting , C.I.or C.C. brackets 32mm alkathene/P.V.C telescopic flush , pipe about 2 M long with one brass coupling and clamps GI ,chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less thane 50grms. 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coats of red oxide primer etc. all complete as per specification and direction of E/I.
(A) 580 mm. long
(c) With 10 lit. low level PVC Cistem
Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I.
(ii) E.W.C. with 'S' trap
(b) 10 lit. low level PVC Cistem
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Supplying fitting and fixing white glazed fire’s clay sink of approved make with overflow arrangements supported on C.I. or R.S. painted brackets 40mm. dia C.P.brass waste with C.P.brass chain and rubber plug 40 mm dia P.V.C. waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams. including cutting wall and making good the same etc. all complete as per specification and direction of E/I.
(i) Kitchen sink 600 mm x 450 mm x 250 mm
Providing and fixing N.P/C.P. brass /P.V.C. porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of Engineer - in -Charge. (c) 150mm dia P.V.C shower
(b)Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror.
(i) 600mm x 450mm size
(c) (i) C.P. brass towel rail 20mm x600mm with bracket container
(c)(iii) C.P. brass liquid soap container
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitionsby cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
Provinding and fixing wash basin wih C.I brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereever required : White Vitreous China Wash basin size 550x400 mm with a 15mm CP Brass single hole basin mixer
Providing and fixing white vitreous china laboratory sink with CI brackets , C.P brass chain with rubber plug 40 mm C.P brass waste and 40 mm CP brass trap with necessary C.P brass unions complete including painting of fittings and brackets , cutting and making good the wall wherever required : Size 600x450x200 mm
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in charge.
Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete Flexible Pipe 32mm Dia
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing PTMT Bottle Trap for Wash basin. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.
Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector.
Providing and fixing CP brass single lever low flow Sink mixer with 15 mm CP brass single lever pillar cock with pop up and waste complete including cutting and making good the walls where required.ROCA make (Model -RT5A3060C00) or Equivalent.
Providing and fixing C.P concealed four way diverter with thermostatic mixer with shut off valve and diverter, including cutting and making good the walls, wherever required. (Make:- Jaquar - Four way diverterKUB-35421, Thermostatic mixer 35671 or Equilent)
Providing & Fixing of Grab Bar size 300mm long in handicap toilet complete as required.Makes & Model No.Jaquar AKP-35701P or Equivalent.
Providing,Fixing satin finish stainless steel AISI 316 grade wall mounted coat hook on door complete. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. MAKE JAQUAR MODEL NO.- ACN-1161N or EQUIVALENT.
Supply, installation, testing and commissioning built with Drinking Water R.O. unit with micron filtration pre-treatment unit, skid mounted R.O. module with pressure pump and pressure tank, drinking water cooler (High quality SS Tank for Storage 80 lts) , complete in all respects. ( Make & Model No. Eureka Forbes Pure Chill RO Storage Cooler cum Purifier or Equivalent)
DRAINAGE INSTALLATIONS
Providing, fixing, testing and commissioning of UPVC SWR pipe type 'B' conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps etc. conforming to IS:14735-1999 and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint as required/applicable.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design:
Providing, fixing, testing and commissioning of UPVC 'P' trap/floor trap/urinal trap of self cleansing design having 50 mm water seal with or without horn conforming to IS : 14735-1999 including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 hard stone ballast 20 mm nominal size) including cost of cutting and making good the walls & floors wherever required. 110 mm inlet x110 mm outlet.
Providing, fixing, testing and commissioning of UPVC inlet fittings (hopper) receive waste from fixture waste with maximum 3 inlets 40, 50 & 63 mm OD size, fabricated from 110 OD UPVC SWR pipe, UPVC sockets, fixed to UPVC traps including solvent weld joint/rubber ring joint, complete with all civil work set in cement concreate 1:2:4 as required including cost of cutting and making good the walls & floors wherever required.
Providing, fixing, testing and commissioning of UPVC cleanout plug conforming to IS : 14735-1999 complete with all fitting; accessories and civil work. 110 mm OD
Providing, fixing, testing and commissioning of UPVC waste Pipe conforming to IS : 4985-2000 class III including all moulding fittings conforming to IS : 7834 (Part-1 - Part -7) 1987 such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including cutting and making good the walls, floors, R.C.C. work etc. (For fixtures waste).
Providing and fixing UPVC floor drain including all fitting and accessories fixed in cement mortar complete in all respect.
75 mm OD x 63 mm OD
110 mm OD x 63 mm OD
Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc.
For 100mm dia. Pipe
For 75mm dia. Pipe
Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) alround 100mm dia. SW / CI / waste pipes including bed concrete as per standard design
Providing, fixing, testing and commissioning of UPVC rain water pipes (IS : 4985-1983 class-III ) including injection moulded fittings (heavy duty) (plain or door) e.g. bends, junction, cowls, tees, offsets, access pieces etc. Clamps/Supports jointing with rubber ring/solvent cement joints including cutting chase or holes in walls and floors and making good as required at Site [For Balcony Drain + Terrace Rain Water Downtake Pipe].
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing G.I. Inlet fitting of suitable size with 2 & 3 Nos. G.I. Socket 32 & 50 welded G.I. pipe and dipped in hot bitumen complete in all respect. 100 mm diameter pipe (Hopper)
Providing and fixing floor drain made of 100 x 50 dia elbow / tee as applicable connected with 50 dia GI pipe painted with primer, two coats of black bituminastic paint,wrapping 1 mm thick PVC tape and final coat of black bituminastic paint B109 complete in all complete including cutting and making good the walls and floor wherever required
Providing and fixing flanged cleanout plug with M.S. flanged tail pieces, blind flang, 6mm dia nut & bolts, gasket and washers fixed to C.I. Pipe with drip seal joint complete in all complete including cutting and making good the walls and floor wherever required with 100 mm dia. Pipe
WATER SUPPLY INSTALLATIONS
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (Exposed on wall Terrace)
15 mm dia, nominal bore
20 mm dia, nominal bore
25 mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50 mm dia, nominal bore
65 mm dia, nominal bore
80 mm dia, nominal bore
Making connection of GI distribution branch with GI main of 50-80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete.
25 to 40 mm nominal bore
50 to 80 mm nominal bore
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)
20mm nominal bore
25 mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50mm nominal bore
65mm nominal bore
Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality
15 mm dia, nominal bore
20 mm dia, nominal bore
25 mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50 mm dia, nominal bore
65 mm dia, nominal bore
80 mm dia, nominal bore
Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete.
20mm nominal bore
25mm nominal bore
32mm nominal bore
40mm nominal bore
50mm nominal bore
65mm nominal bore
80mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm dia nominal bore
Provide and fixing PTMT ball cock of approved quality, colour and make complete with epoxy coated aluminium rod with L.P/H.P.H.D. plastic ball 50 mm dia NB, 242mm long. Weighing not less than 1240 gms.
Providing and fixing chlorinated poly vinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fitting, including fixing the pipewith clampsat 1 m spacing. This includesjointing of pipes &fittingwith one step CPVC solvent cement and cost ofcutting chases and making good the same including testing ofjoints complete as per direction of Engineer in Charge.(Concealed work including cutting chases and making good the walls etc.)
15mm nominal outer dia. Pipes.
20mm nominal outer dia. Pipes.
25mm nominal outer dia. Pipes.
32mm nominal outer dia. Pipes.
Providing and fixing insulation with thermaflex elastomeric nitrile rubber sheets complete with plastering of 20 mm thick insulation with thermaflex elastomeric nitrile rubber sheets for hot water & cold water pipes exposed and chased to sun complete with plastering.
15 mm dia, nominal
20 mm dia, nominal
25 mm dia, nominal
32 mm dia, nominal
40 mm dia, nominal
50 mm dia, nominal
65 mm dia, nominal
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50mm diameter
Providing and fixing Bronze compact(Screwed) Diaphram type pressure reducing valve (PRV) with strainer deliverying desired rate of flow. The complete system is tested to a pressure not less than 16 Kg / Sq.cm and suitable to reduce the pressure upto 1 Kg/Sq.cm) including flanges / unions, nuts, bolts and washers complete as required.
15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore
50 mm dia.
65 mm dia.
80 mm dia.
100 mm dia.
Providing, laying, Jointing, Testing and commissioning of uPVC pressure pipes of 10Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe including bed concrete and thrust blocks at bends as per standard design.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
Constructing masonry Chamber 60x45x50 cm,inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S. bricks
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Under Ground Overhead Tanks.)
25mm dia pipe, 600mm long with size of 250x250x6 mm MS plate
32mm dia pipe, 600mm long with size of 250x250x6 mm MS plate
40mm dia pipe, 600mm long with size of 300x300x6 mm MS plate
50mm dia pipe, 600mm long with size of 300x300x6 mm MS plate
65mm dia pipe, 600mm long with size of 350x350x6 mm MS plate
80mm dia pipe, 600mm long with size of 400x400x6 mm MS plate
100mm dia pipe, 600mm long with size of 400x400x6 mm MS plate
150mm dia pipe, 600mm long with size of 450x450x6 mm MS plate
200mm dia pipe, 600mm long with size of 450x450x6 mm MS plate
Providing, Fixing, Testing & Commissioning of nitrle rubber insulation on hot water supply pipes. K-Flex, A-Flex, Armacell. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.
15mm (9 mm thickness)
20mm (9 mm thickness)
25mm dia (9 mm thickness)
32mm dia (13 mm thickness)
40mm dia (13 mm thickness)
50mm dia (13 mm thickness)
65mm dia (19 mm thickness)
80mm dia (19 mm thickness)
100mm dia (19 mm thickness)
HOT WATER GENERATION SYSTEM
Supply, installion, testing and commissioning of Hot Water Generation Plant with Packaged type Air to Water Heat Pump. These units shall be completely factory assembled including 2 Nos. Scroll Hermatically Sealed Scroll Compressor(s), evaporator, Condenser and Microprocessor Control Panel etc with R410 Referigerant and COP between 3-4. The Heat Pump shall have inbuilt hot water heat exchanger, pumps, valves. expansion valve, integrated CIP system and other accessories.The Heat Pump should be capable of producing hot water at minimum 60°C temperaure at outlet (condenser circuit) temperatures at 10°C ∆T. The Machine should have an operating ambient temperature range of 5°C to 40°C. Location: Terrace Level
a. Built in electric panel as per safety norms as manufacturer standard.
b. All other mountings, fittings & controls with all accessories and safeties
c. All other mounting, fittings and controls.
d. Suitable for electric supply of 415 + 10% volts & 50 Hz.
e. All interconnecting wiring / cabling between heat pump and electrical panel.
f. The Heat pump shall have an in-built facility to start / stop depending on variation in demand at different periods.
g. System shall be complete with SS 304 Tank of 2 Hrs Storage Capacity, Primary and Seconary Circualtion pumps, Heat Exchangers, Return Recirculation Pump, interconnecting piping, valves and all accessories as required.
h. System shall have 20% of total capacity in electrical heating as standby.
i. System shall have an integrated Solar Heating system with 20% of total capacity for energy saving including Flat Plate Solar Panels, Mixing Tanks, Recirculation Pumps, etc
following capacity required for block wise specification as same for all Heat pump.
For Hospital
Heating capacity : Approx. 300 KW (200 KW x 2 working + 1 standby)
SS 304 Hot Water Storage Tank : 4000 Ltrs x 2 Nos
Solar Water Heating 20% - 191 Flat Plate Collector with 1000 Lit tank with coil
Reverse Osmosis Plant (RO) Hospital Block- suitable for 10 hrs operation including filter feed pumps,multigrade sand filter, activated carbon filter, antiscalant dosing, acid dosing, micron cartridge filter, RO high pressure pumps, RO moules, RO Cleaning System, valves, interconnected piping and accessories.
Expected Treated water characteristics after RO Treatment
Total dissolved Solids - < 50 ppm
Suspended Solids - NIL
Turbidity - As per IS:10500
Iron as Fe - NIL
Total Harness - Less Than 5 ppm
Permeate water quantity = 500 lit/hr. described above (a) to (m).
1000 LPH RO
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore
50 mm dia.
65 mm dia.
80 mm dia.
100 mm dia.
Providing, laying, Jointing, Testing and commissioning of uPVC pressure pipes of 10Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe including bed concrete and thrust blocks at bends as per standard design.
Providing & Fixing of Garden hydrant outlet consisting 1 No. 25mm dia. Ball valve,( Brass) for connecting rubber hose, pipes & fittings.
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)
20mm nominal bore
25 mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50mm nominal bore
65mm nominal bore
Constructing masonry Chamber 60x45x50 cm,inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S. bricks
HYDRO-PNEUMATIC SYSTEM
Supply, Installation, Testing And Commissioning Of Compact Self Contained Skid Mounted Hydropneumatic System (Variable Speed) As Follows:
a. Vertical, In-Line, Multisage, centrifugal pumps with SS-304 casing and impeller and SS-316 shaft, CI base & head TEFC motor (with mechanical seal)
(Vendor to submit performance curves and technical catalog of the proposed model for review & information)
b. External Pump mounted or wall mounted microprocessor PID controller(VFD) and frequency inverter integrated in a single body or as separate components with pressure sensor transmitter minimum two lined LCD display, diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocall through RS485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equiped with dry running protection
Quantity : 1 No.
c. Complete (Skid mounted wall mounted / floor mounted) electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (list to be provided by the vendor)
d. Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete.
e. Set of accessories such as pressure switches, pressure transducers, inter connecting power and control cabling etc. complete.
f. Accessories like pressure gauge, MS base frame (Synthetic enamel painted over a coat of primer)
g. GI suction and delivery header with flanges for inlet connection, common outlet header with flanges for outlet connections as required, and interconnecting piping with flexible connections, eccentric type reducers etc. all necessary indigenous accessories as required to complete the installation. Sluice valves at inlet and butterfly valves at outlet, strainer at inlet and NRV at outlet of all pumps shall be provided.
Note:Contractor to note that the suction header is required to have inlet connection from the Puddle Flange @ water tanks and to the pump suction. Provision of delivery header is required to have outlet connection from the pumps. Suitable outlet flanges from the delivery mainfold / header shall be provided as required.
Domestic Booster system for Hospital at terrace as follows:
No. of pumps (2 Working + 1 Standby)
Water Flow Rate - 300 LPM Each
Head - 30 M
WATER SUPPLY, DRAINAGE PUMPS & WATER TREATMENT EQUIPMENTS
Providing, installing, testing and commissining of variable speed (VSPS) hydropneumatic system mounted on a common base plate comprising of vertical centrifugal pumping set with S.S body, stainless steel impeller and mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, one No. microprocessor based controller, dedicated variable frequency drive for each pump, one No.remote sensors, pressure transducers, sequence running cotroller, dry running Protection,motor control centre, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 90 litre capacity M.S diaphragam tank with interchangeable butyl rubber membrane,complete in all respects including stainless steel grade 316 pipe suction and delivery headers and isolation/ control valves( ball valves/butterfly valves/ Nan return valves/ vibration eliminators etc as required) , power box, equipped with fuses/ isolators/circuit breakers as required.
Hyd. System for Domestic Water Supply Pump
Flow rate : 500.0 LPM each
Pumping Head - 70/75 m
1 Set = 2 Nos. pump (1 working+1 standby)
Approx H.P. - 9 HP or as per manufacturer recommendation.
Location - UGH Pump Room
Hyd. System for Flushing Water Supply Pump
Flow rate : 250.0 LPM each
Pumping Head - 70/75 m
1 Set = 2 Nos. pump (1 working+1 standby)
Approx H.P. - 3 HP or as per manufacturer recommendation.
Supplying, installing, testing and commissioning of SS vertical centrifugal pump. Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plate SS Shaft / Impeller / Intermediate chamber along with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, stainer (with by-pass) at suction. Pump shall be provided with mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve (25 dia). The pump shall be suitable for auto/ manual operation. The installation shall be complete with all necessary ancillaries, starter panel / control panel & accessories including base plate complete as required.
The entire Hydropneumatic system shall be factory fitted.
Filter feed pump
Flow rate : 500.0 LPM each
Pumping Head - 35 m
1 Set = 2 Nos. pump (1 working+1 standby)
Approx H.P. - 4.5 HP or as per manufacturer recommendation.
Irrigation Pump
Flow rate : 250.0 LPM each
Pumping Head - 35 m
1 Set = 2 Nos. pump (1 working+1 standby)
Approx H.P. - 1.5 HP or as per manufacturer recommendation.
Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge.
(Pumps shall be installed in a set of two pumps One working and One standby)
Basement & Pump Room Drainage Pumps
(Pumps to be suitable to handle solids upto 12 mm size)
Capacity - 5.0 LPS (Each)
Head - 20 M
H.P. - 2.0 HP Approx.
Sewage Sump Pumps
(Pumps to be suitable to handle solids upto 40 mm size)
Capacity - 5.0 LPS (Each)
Head - 20 M
H.P. - 3.0 HP Approx.
Providing, fixing, testing & commissioning of vertical MSEP filter with adequate dirt holding capacity. Fabricated from FRP sheet as per IS-2825 and manufacturer's specifications complete with intitial charge filter media including painting inside with two coats of non toxic epoxy and with one coat of zinc chromate two coats of synthetic enamel paint outside. Including concrete foudation with cement plaster complete as required. The filter shall also be provided with set of internals for raw water inlet and bottom collecting system. Complete with frontal piping (heavy) . it is designed on 1.50 m / sec velocity.
Dual Media Filter For Domestic Water Supply
Capacity- 30000 LPH
Filtration rate- 13000 LPH/Sqm.
Filter dia approx. - 1800 MM
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
Activated Carbon Filter For Domestic Water Supply
Capacity- 30000 LPH
Filtration rate- 13000 LPH/Sqm.
Filter dia approx. - 1800 MM
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
Supply Installation,Testing & Commissioning of metering pump type chemical doser with 100 lits. HDPE chemical grade solution tank,injection fitting assembly,suction and delivery hose upto the point of injection, capacity 0-6 lph, complete in all respects. Chlorination of Domestic Water
Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts.
All switchboards shall have provision for entry of cables from the top or bottom as required.
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position.
Electric Panel For Water Supply Pumps at Water Supply Pump Room
INCOMING
1 No. 63 amps TPN MCCB with the following accessories:
1 No. square flush mounting 0-500 volts scaled voltmeter with three way and OFF switch.
Three phase indicating lights.
Electrolytic high conductivity three phase and neutral tinned copper bus bar rated at 100 amps having a current density of 1 amp per Sqmm suitable to with stand symmetrical fault level of 25 MVA at 415 volts. The neutral bus bar is to be of 100% capacity.
OUTGOING UNITS
Ten 25/40 Amp. TP + NL M.C.C.B. with rotary handle of breaking capacity 25KA
Two 63 Amp. TP + NL M.C.C.B. with rotary handle of breaking capacity 25KA
8 Nos. fully automatic DOL starters with push buttons and ON/OFF indicating lights and overload relays for 1.5 to 7.5 HP pump .
6 Nos.cyclic relay for automatic duty changeover of pumps.
8 No. single phase preventors.
Space for 3 Nos. Level Controllers.
Switchgear shall be suitable for the HPS of various motors.
1 Nos. 63 Amp. TPN MCB Spare.
2 Nos. 32/40 Amp. TPN MCB Spare.
The motor control panel shall be prewired with colour coded wires with identification labels complete in all respects as required.
Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to probes of required.
Level Controller For Water Supply Pump:
To start pump when water level is low in Domestic Water U.G. tank and shut off pump when Domestic Water U.G. tank is full. Also to stop when water level is low in raw water underground tank.
Level Controller For Sump Pumps:
To start pump when water level is high in sump and shut off pump when sump is empty. Both pumps are start when sump is over flowing.
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete.
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified .
50 mm dia
65 mm dia
80 mm dia.
100 mm dia.
150 mm dia
Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified.
50 mm dia
65mm dia.
80 mm dia.
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 16 Kg/Sqcm.
50 mm dia
65 mm dia
80 mm dia
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects.
Power cable Copper 3 core 10 sq.mm
Power cable Copper 3 core 6 sq.mm
Power cable Copper 3 core 4 sq.mm
Control cable copper 2 core 1.5 sq.mm
SEWERAGE & DRAINAGE INSTALLATIONS UPTO MAIN ROAD FIRST MANHOLE
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:
150 mm diameter
200 mm diameter
250 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:
150 mm diameter S.W. pipe
200 mm diameter S.W. pipe
250 mm diameter S.W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
150 mm diameter S.W. pipe / RCC pipe
200 mm diameter S.W. pipe / RCC pipe
250 mm diameter S.W. pipe / RCC pipe
300 mm diameter S.W. pipe / RCC pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 150mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
250 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
500 mm dia. R.C.C. pipe
600 mm dia. R.C.C. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes: Size 90 x 80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68 m to 2.29 m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality HD - 20 Circular shape 560 mm internal diameter
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
For pipes 100 to 250 mm diameter
For pipes 350 to 450 mm diameter
Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing F.R.P. Grating drain cover M.S. Angle ( 35 x35 x 5 mm). ( Load Bearing cap. 5 T, suitable for car parking, basement, Pump room, Parking Area ). 377mm wide and 30mm thick
FIRE FIGHTING WORKS
PUMPS 1.NOC from fire authority shall be in the scope of Contractor . Only fee paid to the fire authority shall be reimbursed against the submission of the receipt and nothing shall be paid extra.
2. All the Fire Fighting works shall be done in compliance of Fire Fighting authority requirement.
Note-Pump shall be capable of furnishing not less than 150% of rated capacity of water at a head of not less than 65 % of rated head. The shut off head shall not exceed 120% of rated head.
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
2850 lpm at 88 m Head (For Hydrant & Sprinkler System).
1620 lpm at 56 m Head (For Water Curtain System).
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
2850 lpm at 88 m Head (For Hydrant & Sprinkler System).
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump).
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 lpm at 88 m Head (For Hydrant & Sprinkler System).
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
900 lpm at 35 m Head
CONTROL PANELS
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
Incomings
630A, 50kA 4 Pole MCCB, Ics=100% Icu rating
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps
Set of Copper Bus Bar 800A
Outgoings
Main Fire Pump
Jockey Pump
Diesel Engine Control
Control for diesel engine comprising -
Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication
All standard relays and accessories for automatic operation of diesel engine
System Controller
Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.
Supplying,Installation,testing & commissioning of dust & vermin proof double door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCA sheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.
Incomming
63 Amps. TP & N SFC with HRC fuses
Set of 3 phase indication lamp
Suitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge.
4 x 25 sqmm ( 28 mm )
3.5 x 50 sqmm ( 35 mm )
3 X 10 sq. mm (22mm)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 150 mm width x 50mm depth x 1.6 mm thickness.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred.
4 core, 25 sq.mm. Aluminium Armoured
3.5 core, 50 sq.mm. Aluminium Armoured
3 core, 10 sq.mm. Aluminium Armoured
Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as per IS 15642-2006 . Thickness of insulation mat shall be not less than 2 mm to withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge.
PIPES & ACCESSORIES
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground )
150 mm. Dia
100 mm. Dia
80 mm. Dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor)
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia (wall thickness 6.3 mm)
250 mm dia (wall thickness 6.3 mm)
300 mm dia (wall thickness 7.1 mm)
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
50mm dia
65mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
100 mm dia
150 mm dia
200 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 36 m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
2 way-100 mm dia M.S. Pipe.
4 way - 150 mm dia M.S. Pipe. (FOR UG TANK & EXTERNAL RING MAIN)
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Upright Sprinkler
Horizontal side wall sprinkler
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.
100mm dia
150mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Supplying, installation, testing & commissioning of deluge valve (to be used for water curtains) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required. 80 mm dia
Providing, installation, testing & commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required.
Providing, installation, testing & commissioning of electric release trim assembly for deluge wall with two way solelnoid valve, weather proof operation on 24 volts DC supply complete as required.
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.
Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2 & 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & "FIRE HOSE" written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE )
Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted "FIRE" in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge.
Pressure Vessel Supplying, installing, testing and commissioning of pressure vessel for pressurization of fire system complete with valves at outlet / drain to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, outside with one coat of primer & two coats of synthetic enamel paint of approved shade complete as required to operate commonly main fire pump, sprinkler pump & jockey pump at drop of pressure, automatically at required pressure setting. Complete as per manufacturer's specifications & as directed by Engineer- in-charge. working pressure:- 11 kg/sqcm test pressure: 20 kg/sqcm (450 mm dia & 2000 mm height)
Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges.
150 mm dia
80 mm dia
Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 25 mm Dia
Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser.
Providing & fixing cast iron 100 mm dia. Foot valve with nuts, bolts, 1.5 mm thick CAF gasket complete with all accessories (To be provided into UG Fire Water Tanks).
Supply and fixing of 4 Nos G.I round bottom FIRE BUCKET of 9 LTR. Capacity field with sand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIRE complete in all respects as per direction of Engineer Incharge .
Providing, fixing water flow meter on test line complete with all accessories for flow indication , monitoring & testing of fire pumps with bypass arrangment including piping & bypass valves. 150 mm dia
FIRE EXTINGUSHER
Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge.
Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge.
Providing and fixing 9.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge.
Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:13386 .
Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEY confirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285.
Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with imported Novec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions.
Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc.
Add GST 18 %
Add Labour cess 1%
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.pdf
Tender Documents • 0.53 MB
Tenderdocument_2.pdf
Tender Documents • 2.31 MB
Tenderdocument_3.pdf
Tender Documents • 12.44 MB
BOQ.xls
BOQ • 1.89 MB
Tenderdocument_4.pdf
Tender Documents • 9.74 MB
Tenderdocument_5.pdf
Tender Documents • 3.38 MB
Download all tender documents and submit your bid