Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹23.0 L+₹46,189.65 (2.05%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹24.3 L+₹1.8 L (7.91%)Rejected-Finance DEVERTHA NO 1 SHAHGANJ AGRA | AGRA | AGRA | UTTAR PRADESH | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹52,000
Closing Date
15 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Vijay Kumar Sharma
Garrison Engineer West Agra Cantt
PROVISION OF CERTAIN SRW LBW WORKS AT 50 I PARA BDE OFP UNDER AGE BR II OF GE WEST AGRA
2021_MES_413221_1
8012/781/E8
Open Tender
Civil Works
Item Rate
180 days
GE West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE West Agra
₹52,000
19 Apr 2021
16 Jan 2021
17 Feb 2021
16 Jan 2021
15 Feb 2021
1 Feb 2021
60 days
Amount
Excavation in trenches n.exc 1.5 m wide and not exc 1.50 m depth for foundation etc not exc 10 sqm on plan and getting out in any type of soil complete all as specified & as directed.
M&L plain cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified & as directed.
Returning filling in soft / loose in trenches after laying pipes, construction of man holes etc including spreading, leveling and watering and well ramming in 25 cm thick layers complete all as specified and directed.
Removing surplus excavated materials to a distance exc 250m but not exc 500 m and depositing where directed at a level not exc 1.5 above the starting point complete all as specified & as directed.
M&L for brick work with sub class 'B' old size brick straight or curved on plan exc. 6m mean radious built in CM 1:4 complete all as specified & as directed.
M&L for rendering in CM 1:4, 15 mm thick on fair faces brick work or concrete surface, finished even and smooth (without using extra cement) complete all as specified & as directed.
M&L cement concrete 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregate) as in surface channels and drains complete all as specified & as directed.
M&L cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in coping, benching, water troughs and the like including weathering, slightly arounded or chamfered angle complete all as specified & as directed.
M&L precast cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) in cover slabs for man holes etc. set in cement mortar 1:6 complete all as specified & as directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape as required, including cranking, bending spirally, hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & as directed.
Taking down chowkats or frames (w/o taking off shutters) from the frames n.exc 1.5 Sqm each complete all as specified & as directed.
Taking down chowkats or frames (w/o taking off shutters) from the frames exc 1.5 Sqm and not exc. 4 Sqm each complete all as specified & as directed.
S&F Pressed steel door frame of size 105x60 mm with one or more rebates including necessary fixing lugs, hinges, lock & strike plate etc. complete all as specified & as directed.
M&L for PCC 1:3:6, type C-1 (using 20 mm graded stone aggregate) as in back filling of pressed steel door frames complete all as specified & as directed.
S&F 30mm thick 2nd class hard wood plain framed panelled shutter (any No.of panels), with panels of timber flat on both sides (feather edged) or of veneered particles board medium density, wooden particle board with commercial face veneers complete all as specified & as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening complete all as specified & as directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified & as directed.
S&F extruded aluminium alloy handles, fabricated, anodised, size of handle 150mm complete all as specified & as directed.
S&F aluminium anodized barrel tower bolts, 150mm long complete all as specified & as directed.
S&F aluminium alloy anodised sliding door bolts with hasp and staple (bolt type) and fixing clips of sheets cast or extruded sections and fixing bolts and sliding bolts or extruded section of cast aluminium alloy length of bolt 250mm complete all as specified & as directed.
S&F framed work such as grills, gratings etc with ends of bars shouldered or riveted or framed guard bars similar work conforming to Fe-290 Gde E-165 complete all as specified & as directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handles and steel pegstay complete with glazing bars dovetailed or welded complete all as specified & as directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified & as directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified & as directed.
S&F 3mm thick figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sq. m in each pane complete all as specified & as directed.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or with staples complete all as specified & as directed.
Dismantling of ceiling board (Fibre, pulp, insulation etc) or insulation board / slabs / any thickness including cover fillets complete all as specified & as directed.
S & F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre complete all as specified & as directed.
M&L for 4 mm thick non asbestos fibre cement building designer boards in ceiling or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified & as directed.
Demolition of cement concrete (reinforcement cut as required to facilitate demolition) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified & as directed.
M&L for reinforced cement concrete 1:2:4 (Nominal Mix), type B-1 (using 20mm graded crushed stone aggregate) as in .beams, cantilevers, bressummers, lintels upto 1.5m span complete all as specified & as directed.
M&L for TMT bars 5mm and above but including 10mm dia and ove, cut to length, bent to shape required, including crancking, bending spirally hooping ends binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality in stirrups complete all as specified & as directed.
Demolition of brickwork masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, precast concrete articles complete all as specified & as directed.
M&L brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 using old size bricks complete all as specified & as directed.
M&L brick work with subclass ‘B’ bricks (except brick), straight or curved on plan exc 6m mean radius, built in CM 1:6 using old size bricks complete all as specified & as directed.
Taking down cement plaster in any cement mortar on stone wall including racking out joints hacking for key scrubbing down with water etc complete all as specified & as directed.
M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and fair complete all as specified & as directed.
M&L for rendering 15 mm thick in CM 1:4 on surface other than fair face of brickwork or concrete surfaces including ming of WPC as per manufacturer's direction complete all as specified & as directed. (WPC will be measured & paid separately under separate items as supply only)
M&L rendering 10 mm thick in CM 1:3 on ceiling of concrete surfaces finished the surface fair and even complete all as specified & as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified & as directed.
Supply only Integral water proofing compound complete all as specified & as directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified & as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified & as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & as directed.
M&L for non - skid ceramic coloured floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 300 x 250 x 7 mm / 450 x 350 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over 20 mm thick screed bed in CM (1:6) complete all as specified & as directed.
Demolition of cement concrete ( unreinforced) in ground floor and paving n.exc 15 cm thickness below or above the gd level complete all as specified & as directed.
M&L for cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) in plinth protection 50mm thick finished even and smooth without using extra cement including making joint 12 wide to the full depth of PCC at max 3 mtrs and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified & as directed.
Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed
Dismantling timber scantlings 40 sq. cm and over in section, in any position framed work complete all as specified & as directed.
Taking down roof trusses, coupled rafters or trussed beams clear span above 4 metres & upto 8 metres complete all as specified & as directed.
S&F roof trusses (framed), trussed, purlins and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410 -W (Gde-E- 250) quality-A complete all as specified & as directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde-E- 250) quality-A complete all as specified & as directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, eachscrewed end to be fitted with washers and one hexagonal or square nut,length of bolt exc 22.5cm and n exc 30cm and diameter of neck 16mm to 20mm complete all as specified & as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550mpa as in roof covering/cladding to wall, fixed with self tapping screws in hangers all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & as directed.
M&L for preparation of new or previously untreated steel surfaces over 10cm in width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & as directed.
M&L for preparation of new or previously untreated wooden surfaces over 10cm in width or grith and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & as directed.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified & as directed.
S&F in repairs vitreous china wash hand basin white flat back, size 550x400 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets, cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified & as directed.
S&F in repairs pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified & as directed.
S&F in repairs bib tap cost copper alloy chromium plated fancy type with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule in 15 mm bore complete all as specified & as directed.
S&F vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and Pedestal pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. complete all as specified & as directed.
S&F in repairs gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe for 20 mm bore dia of pipe complete all as specified & as directed.
S& F in repairs 110mm bore PVC (SWR) pipes single socketed in any lenth with rubber ring joints, to wall or floor complete all as specified & as directed.
S& F in repairs 75mm bore PVC (SWR) pipes single socketed in any lenth with rubber ring joints, to wall or floor complete all as specified & as directed.
S&F PVC (SWR) bends any radius 75mm dia complete all as specified & as directed.
S&F PVC (SWR) bends any radius 110mm dia complete all as specified & as directed.
S & F in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent dia of out let 75mm complete all as specified & as directed.
S&F in repairs PVC low level flushing cistern 10 ltrs capacity white with inlet ball value, float valve and handle including brackets, CP brass flush pipe and bend complete all as specified & as directed.
S&F PVC connection 450mm long and 15mm dia to flushing cistern/ sanitary fittings with PTMT nuts of length 450mm at the ends complete all as specified & as directed.
S&F in repairs 15 mm bore stop valves, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified & as directed.
S&F in repairs shelf of PTMT fixed and including chromium plated brass screws & wooden/plastic cleats (Minimum weight 300 gms) complete all as specified & as directed.
S&F in repairs chromium plated shower roses 125 mm size with or without swivel joints any size including fixing to steel pipe or unoin complete all as specified & as directed.
S&F in repairs 15 mm dia cast copper alloy chromium plated angle cock complete all as specified & as directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified & as directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified & as directed.
M&L for GI tubing 15mm dia medium grade with all fittings complete to wall and ceiling or laid in floors complete all as specified & as directed.
M&L for GI tubing 20mm dia medium grade with all fittings complete to wall and ceiling or laid in floors complete all as specified & as directed.
Fixing only tubes any grade with all fittings complete to wall and ceiling or laid in floors 15mm dia complete all as specified & as directed.
Fixing only tubes any grade with all fittings complete to wall and ceiling or laid in floors 20mm dia complete all as specified & as directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall complete all as specified & as directed.
Dismantling water tanks of capacity of water tank 1000 ltr complete all as specified & as directed.
S&F rotational moulded polyethylene water storage tanks 1000 liter capacity (cylindrical vertical with closed top) with and including ball brass valves, high pressure with polythene float and fly nut complete screwed for 20 mm bore iron pipe or for brass ferrule, hoisted and fixed in position complete as specified in SSR Part I 2009 complete all as specified & as directed.
S & F 20 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified & as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, lamp holders, light fitting etc removing materials to store for keeping in safe custody for taking credit or reuse serviceable fittings/fixtures and making good the disturbed surfaces of wall/floors complete all as specified & as directed.
M&L for Point wiring in concealed conduit with 1.5 Sqmm PVC insulated flame retardent low smoke (FRLS) single core stranded copper conductor for one light/fan/bell point in and including PVC conduit 19/20 mm dia to be terminated in pressed steel terminal boxes with 3 mm thick bakelite sheet top cover including 1.5 sqmm PVC insulated "Flame Retardent Low Smoke"( FRLS)" single core stranded copper earth continuity conductor controlled by one switch and/or one regulator and making good the disturbed surface complete all as specified and directed. (Wiring shall be made as per colour code in IS for Phase, neutral and earth)
All as per above but for One socket outlet 5/6 Amps on independent bd controlled by one switch.
All as per item no 2 above but for One socket outlet 5/6 Amps controlled by one switch on same board with other switches
All as per item No 2 here in before but one socket out let 15/16 Amps controlled by one switch on independent board and wiring with 2.5sqmm cable.
S&F switch piano, flush type, single pole, 15/16 Amps one way, 230 volts, complete all as specified & as directed.
S&F socket outlet 15/16 Amps multipurpose 3 pin 230 V complete all as specified & as directed.
S&F switch piano flush type single pole , 5/6 Amps one way, 230 volts, complete all as specified & as directed.
S& F socket outlet 5/6 Amps flush type piano 5 pin 230 volts complete all as specified & as directed.
S&F ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified & as directed.
S&F lamp holder , insulated body ,with back plate suitable for batten fitting complete all as specified and directed.
S&F LED Bulb 15 watt suitable for lamp holder complete all as specified and directed.
S&F in replacement surface/wall mounting LED batten 20 watt luminaire having Aluminium housing and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-LUMILINEPLUSBS20WLED865SPCSS or equivalent Model of Philips/Bajaj/CG as approved by GE.
Supply & fix in replacement, outdoor street light LED 30 watt luminaire white powder coated with extruded grey aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- SL30WLED757SASYTOPCMP or equivalent as approved by GE.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor complete all as specified & as directed.
M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 2.5 sqmm drawn in and including PVC rigid conduit medium grade not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 1.5 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 1.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces complete all as specified & as directed.
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 200 amps rated bus bar 240 volts complete all as specified and directed.
Supply & fix MCB SPN, 40 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed.
S & F MCB 6 to 40 Amps SP, 240 Volt C, series complete all as specified and directed.
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .
S&F iron metal body heavy duty exhaust fan 300mm sweep, 230 volts, 50 Hz, including connecting from ceiling rose to fan connector complete all as specified and directed
S&F iron metal body heavy duty exhaust fan 450 mm sweep, 230 volts, 50 Hz, including connecting from ceiling rose to fan connector complete all as specified and directed
Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core complete all as specified and directed.
Excavation in trenches getting out in soft/loose soil n.exc 1.50M wide and not exc. 1.50M in depth for foundation etc or for shafts, wells, cess pits, manholes etc area n exc. 10 Sqm on plan and not exc 1.5 in depth complete all as specified and directed.
Removing excavated material (soil) to a distance 50 mtr and not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply & laying reinforced precast concrete cable cover, class LV, type-I, flat, size 250 mm x 150 mm x 40 mm for cable protection complete all as specified & dirrected.
M&L for sand cushioning dry, fine for cable cushioning 8 cm below the cable and 15 cm above duly punned down to 18 cm over all complete all as specified & directed.
Balaji Associates
M/S Solanki Brothers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .