TENDER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
*Similar nature of work means: "Erection and commissioning of 25 KV O H E . O R Erection/Modification of power supply installations for 25KV O H E . O R Erection and commissioning of 132 KV and above voltage transmission line. O R Erection and commissioning of 132/33 KV and above voltage level substations"
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Design , supply, erection, testing & commissioning for the work for isolation of main line at KCI/Siding , RNQ (RGML siding), SLBN, Karala Road, Singrauli, Krishan Shila, Shakti Nagar, MHDA, ANH/SP & NBG/SSP in DHN & DDU division under Railway Project Danapur OF East Central Railway.
RP-DNR-EL-2X25KV-ISOLATI-~ECR
RP-DNR-EL-2X25KV-ISOLATI-
Open
Works - General
12 Months
Patna, Bihar
₹0
₹19.5 L
28 Oct 2026
28 Oct 2026
11 Nov 2026
175 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 9,76,53,855.23 | ||
| — | 108.00 | — | — | ||
| Supply and Erection of OHE Structure Portal/Mast/TTC/Super Mast/AT Mast RDSO no. ETI/OHE/13(4/84) or latest/ (a) Supply | — | — | — | 1,43,92,080 | |
| — | 108.00 | — | — | ||
| (b) Erection | — | — | — | 9,47,155.68 | |
| — | 100.00 | — | — | ||
| Supply & erection of 25KV caution, board as per RDSO DRG.no.ETI/OHE/P/7531or latest | — | — | — | 49,150 | |
| — | 240.00 | — | — | ||
| Concreate for foundations and plinths -other than hard soil (M-15) | — | — | — | 24,15,835.2 | |
| — | 250.00 | — | — | ||
| Reinforcement | — | — | — | 26,112.5 | |
| — | 14.00 | — | — | ||
| Supply & Erection of small part of steel ETI/OHE/13(4/84) & 49 (9/95)or latest" | — | — | — | 18,95,654.88 | |
| — | 1400.00 | — | — | ||
| Supply & Erection of Copper Jumper 160 sq mm RDSO Spec. no.ETI/OHE/3(2/94) Rev - 1 or latest | — | — | — | 10,23,610 | |
| — | 60.00 | — | — | ||
| — | — | — | 2,36,565.6 | ||
| — | n : - no.TI/SPC/OHE/INSCOM/1070(1/07 | """Supply&Erection of or latest""" | — | ||
| — | — | — | insulator. | ||
| — | — | — | RDSO | ||
| — | 60.00 | — | — | ||
| Erection | — | — | — | 39,304.2 | |
| — | 210.00 | — | — | ||
| Supply & Erection of PG clamp (1030/1040) RDSO no. ETI/OHE/G/SK/231 or latest | — | — | — | 61,534.2 | |
| — | 110.00 | — | — | ||
| Rainforced concrete for foundation and trench | — | — | — | 10,35,147.3 | |
| — | 10.00 | — | — | ||
| Supply & erection,tseing and commissioning of 25 KV single pole Vaccum Circuit breaker with connector and all accessories RDSO SpecTI/SPC/PSI/LVCBIN/0120 (DEC 2013) OR LATEST/ (a) Supply | — | — | — | 63,77,950.7 | |
| — | 10.00 | — | — | ||
| (b) Erection ,Testing & Commissioning | — | — | — | 1,76,521.4 | |
| — | 14.00 | — | — | ||
| Supply,Erection,Testing& commissioning of 25 KV single pole vacuum interrupter RDSO Spc. No.- TI/SPC/PSI/LVCBIN/0120 (Dec-2013) Ver 0 with A and C slip No. 1 (oct 2016) or latest/(a) Supply | — | — | — | 72,93,899.48 | |
| — | 14.00 | — | — | ||
| (b) Erection ,Testing & Commissioning | — | — | — | 1,48,326.64 | |
| — | 20.00 | — | — | ||
| Supply of 25 KV PT type -I RDSO no. ETI/Spc/PSI/PT/0210/06-2021 or latest(a) Supply/ | — | — | — | 18,22,118.8 | |
| — | 20.00 | — | — | ||
| (b) Erection of 25 KV PT type -I RDSO no. ETI/Spc/PSI/PT/0210/06-2021 or latest | — | — | — | 38,259.4 | |
| — | 10.00 | — | — | ||
| Supply & Erection of 25 KV PT type -II RDSO no. ETI/Spc/PSI/PT/0210/06-2021 or latest(a) Supply/(a) Supply | — | — | — | 9,64,556.5 | |
| — | 10.00 | — | — | ||
| (b) Erection | — | — | — | 21,929.6 | |
| — | 10.00 | — | — | ||
| (a) 25 Kv ETI/PSI/90(06/95)/ Supply | — | — | — | 17,77,619.5 | |
| — | — | — | Ratio | ||
| — | — | — | 1500-750/5A | ||
| — | 10.00 | — | — | ||
| Erection | — | — | — | 25,718.8 | |
| — | 8.00 | — | — | ||
| Supply Erection testing and commissioning of control and Relay panel as per latest RDSO specification | — | — | — | 2,49,91,417.68 | |
| — | 300.00 | — | — | ||
| Supply of earth screen wire of size 19/2.5 mm | — | — | — | 1,12,467 | |
| — | 300.00 | — | — | ||
| Erection of earth screen wire of size 19/2.5 mm | — | — | — | 4,503 | |
| — | 1200.00 | — | — | ||
| Supply and errection of cupper cross fedeer 150 sq mm (37/2.25 ) HDBC ./ Supply | — | — | — | 17,15,820 | |
| — | 1200.00 | — | — | ||
| Errection | — | — | — | 52,032 | |
| — | 200.00 | — | — | ||
| Supply & spreading of ballast/grvels in the switch yard | — | — | — | 4,09,568 | |
| — | 160.00 | — | — | ||
| Supply of 150 sq mm copper feeder wire ending cone as per drawing no ETI/OHE/P/1130 or latest | — | — | — | 1,97,628.8 | |
| — | 1600.00 | — | — | ||
| Supply & Erection of cables for Interrupter for control Indication/ (a)2X 7 corex2.5 sq.mm copper | — | — | — | 4,43,216 | |
| — | 1400.00 | — | — | ||
| (b) 2 core x 2.5 sq.mm copper | — | — | — | 2,15,166 | |
| — | 1600.00 | — | — | ||
| (c) 2 core x 4 sq.mm copper | — | — | — | 2,57,536 | |
| — | 1400.00 | — | — | ||
| (d) Cable of 2 core 10x2.5 sqmm | — | — | — | 4,21,624 | |
| — | 16.00 | — | — | ||
| Supply of DP isolator with SPS RDSO No- ETI/OHE/16(1/94) or latest | — | — | — | 15,63,897.6 | |
| — | 16.00 | — | — | ||
| Erection of DP isolator with SPS RDSO No- ETI/OHE/16(1/94) or latest | — | — | — | 97,220.32 | |
| — | 60.00 | — | — | ||
| Supply & Erection of Alluminium Bus Bar Connector/ (a)Bus terminal ( 6480 ) | — | — | — | 2,59,410.6 | |
| — | 60.00 | — | — | ||
| (b) Bus splice ( 6490 ) | — | — | — | 2,26,146 | |
| — | 75.00 | — | — | ||
| © Bus Tee connector ( 6500 ) | — | — | — | 2,96,845.5 | |
| — | 175.00 | — | — | ||
| (d) Terminal connector 36/20 mm ( 6530 ) | — | — | — | 5,82,452.5 | |
| — | 75.00 | — | — | ||
| ( e) Tap connector ( 6520 ) | — | — | — | 2,42,838 | |
| — | 75.00 | — | — | ||
| (f) Terminal connector ( Bolted type) (6830-I ) | — | — | — | 2,14,012.5 | |
| — | 10.00 | — | — | ||
| Supply Erection, testing & commissioning of RTU at SP/FP control Post, modification including modification in SCADA software at RCC with cable & commissioning materialsRDSO Spec. TI/SPC/RCC/SCADA/0133 with latets amendments | — | — | — | 1,19,11,466 | |
| — | 20.00 | — | — | ||
| (a)Supply & Erection of 25 kv single pole 1600 amp isolator including insulators with all fitting and accessories including & Erection of isolator as per Drg no. ETI/OHE/G/05513 sh-1 | — | — | — | 11,92,621.8 | |
| — | 50.00 | — | — | ||
| (b)Supply of operating rod insulator | — | — | — | 1,62,132.5 | |
| — | 120.00 | — | — | ||
| — | — | — | 13,15,620 | ||
| — | :- Supply | and errection or latest | — | ||
| — | — | — | RDSO | ||
| — | — | — | Spec. | ||
| — | 320.00 | — | — | ||
| Supply & Errection of Bimetallic connector for ACSR Zebra RI no. 11030 | — | — | — | 4,96,947.2 | |
| — | 50.00 | — | — | ||
| Supply of bus bar junction and connector (ID-11140) | — | — | — | 2,02,597 | |
| — | 50.00 | — | — | ||
| Erction of bus bar junction and connector (ID-11140) | — | — | — | 4,393.5 | |
| — | 150.00 | — | — | ||
| Supply & Erection of earth electrode with earth pit RDSO no.ETI/OHE/P/7021(8/84) or latest | — | — | — | 6,07,014 | |
| — | 450.00 | — | — | ||
| Supply & erection of 50X6 MS flat for earthing. | — | — | — | 1,37,745 | |
| — | 751.00 | — | — | ||
| Supply & erection of 75X8 MS lead in the ground for earthing | — | — | — | 3,10,245.61 | |
| — | 420.00 | — | — | ||
| Supply & erection of Tubular aluminium bus bar (50 x 39 mm dia) | — | — | — | 4,80,698.4 | |
| — | 120.00 | — | — | ||
| Supply of Expansion type terminal connector to suit 50 mm dia aluminium tubular bus bar, terminal pad of 25 KV CT/isolator (ID-11060) | — | — | — | 8,52,267.6 | |
| — | 120.00 | — | — | ||
| Erection of Expansion type terminal connector to suit 50 mm dia aluminium tubular bus bar, terminal pad of 25 KV CT/isolator (ID-11060) | — | — | — | 4,591.2 | |
| — | 75.00 | — | — | ||
| Supply of 25 KV system TEE connector to suit 50 mm O/D aluminium tubular bus bar (ID-11150)/ (a) Supply | — | — | — | 3,42,399 | |
| — | 75.00 | — | — | ||
| (e) Erection | — | — | — | 7,029 | |
| — | 75.00 | — | — | ||
| Supply of 25 KV system rigid bus splice connector to suit 50 mm O/D aluminium tube on both ways (ID-11180)/ (a) Supply | — | — | — | 3,21,599.25 | |
| — | 75.00 | — | — | ||
| (e) Erection | — | — | — | 6,785.25 | |
| — | 10.00 | — | — | ||
| Supply & Erection Terminal board in control cubicle | — | — | — | 1,19,376.2 | |
| — | 80.00 | — | — | ||
| Supply (other than insulators ) of materials (including insulator) for termination of copper cross feeder wire | — | — | — | 7,93,395.2 | |
| — | 80.00 | — | — | ||
| Erection of materials (including insulator) for terimation of copper cross feeder wire | — | — | — | 1,06,186.4 | |
| — | 250.00 | — | — | ||
| Supply & Erection of copper strip for earthing | — | — | — | 1,93,197.5 | |
| — | 500.00 | — | — | ||
| Supply & erection of Aluminium bus bar ( 36/28 mm dia) as per latest RDSO spec. | — | — | — | 2,79,865 | |
| — | 1500.00 | — | — | ||
| Structural steel work in single section including cutting, bending, straightening, drilling revetting bolting hoisting, fixing in position, including applying a priming coatof approved steel primer, complete- up to 2 mtr hight above GL, In RSJ, tees ,angles and channel . | — | — | — | 1,26,900 | |
| — | 320.00 | — | — | ||
| Supply & Erection Cable trench & cover. | — | — | — | 8,78,800 | |
| — | 10.00 | — | — | ||
| Supply of 110 V DC distribution boards as per RDSO specification. | — | — | — | 3,55,765 | |
| — | 10.00 | — | — | ||
| Erection, testing and commissioning of 110 V DC distribution boards as per RDSO specification. | — | — | — | 13,492.8 | |
| — | 10.00 | — | — | ||
| Supply of an iron clad 110 V, DC fuse box | — | — | — | 41,896.2 | |
| — | 10.00 | — | — | ||
| Erection of an iron clad 110 V, DC fuse box | — | — | — | 1,433.1 | |
| — | 10.00 | — | — | ||
| Supply and Erection of 240 V AC Distribution Board | — | — | — | 6,64,970 | |
| — | 280.00 | — | — | ||
| Supply of PG clamp RI 1051-3 | — | — | — | 1,16,468.8 | |
| — | 22.00 | — | — | ||
| Supply & Erection of 42 KV lightening Arrester RDSO no. ETI/PSI/71(1/87) or latest | — | — | — | 10,75,297.52 | |
| — | 50.00 | — | — | ||
| Supply of Soild copper bus bar connector (Bus terminal ) | — | — | — | 91,026 | |
| — | 50.00 | — | — | ||
| Erection | — | — | — | 940 | |
| — | 18.00 | — | — | ||
| Supply & erection of Catenary copper jumper or latest | — | — | — | 58,792.32 | |
| — | 25.00 | — | — | ||
| Supply & erection of 7 mm HD copper dropper wire. | — | — | — | 18,049 | |
| — | 100.00 | — | — | ||
| Supply of Soild copper bus bar connector (Bus terminal ) | — | — | — | 2,16,597 | |
| — | 100.00 | — | — | ||
| Erection | — | — | — | 1,961 | |
| — | — | — | Above/ 130477.60 Below/P | ||
| Suuply of a structure bond (Including black paint M S Flat and required nut, bolts spring washer. | — | 110.00 | — | — | |
| — | 110.00 | — | — | ||
| Erection of a structure bond (Including black paint M S Flat and required nut, bolts spring washer. | — | — | — | 43,149.7 | |
| — | 2.00 | — | — | ||
| Supply of fencing upright | — | — | — | 2,61,585.02 | |
| — | 2.00 | — | — | ||
| Erection of fencing upright | — | — | — | 14,741.18 | |
| — | 150.00 | — | — | ||
| Supply of fencing panel as per RDSO approved drawing | — | — | — | 5,96,875.5 | |
| — | 150.00 | — | — | ||
| Erection of fencing panel. | — | — | — | 23,613 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ClarificationregardingsubmissionofAnnexue-V.pdf
ATTACHMENT
GCCUpdateduptoACS-12_02_09_26.pdf
ATTACHMENT
UDINClarification.pdf
ATTACHMENT
TP.pdf
ATTACHMENT
2026_06_16Acceptanceofe-BankGuaranteee-BGinWorksContractsandPGMS_PMS_PSSAGC.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .