| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance MCB Z 5 04939 GURU GOBIND NAGAR BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
7 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) SIRSA
GE(AF) SIRSA 125055
AS PER BOQ/PRICE SCHEDULE
2021_MES_452154_1
GE/SRA/T-21 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
GE(AF) SIRSA
AS PER NIT/TENDER DOCUMENTS
5 documents required · 5 mandatory
₹500
GE(AF) SIRSA
₹36,000
15 Jul 2021
17 Jun 2021
9 Jul 2021
17 Jun 2021
7 Jul 2021
2 Jul 2021
17 Jun 2021 - 29 Jun 2021
60 days
Amount
Taking down Copper/Aluminium Point Wiring any type including PVC casing caping /PVC Conduit (Light, Fan, Socket or Power) excluding Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings of any description and Making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
Taking down/out unserviceable Wires only (but except Fittings & Fixtures viz Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting, etc.) from the Existing Point Wiring (Light, Fan, Socket or Power) without disturbing PVC Casing & Caping/PVC or Steel Conduits/ERW Conduit of any description, complete all as specified and as directed.
Taking down/out unserviceable Wires only from the existing Sub-main Wiring of any type and any description, without disturbing Existing Conduit, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed.
Add to item No 4 for each additional light/Fan point on the same circuit complete all as directed by Engineer in Charge.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire drawn through Existing Rigid Non-metallic PVC Conduit, Earth Continuity Cable connected to Common Earth dolly for ONE 5 PIN SOCKET OUTLET 6 AMP ON THE SAME BOARD, complete all as specified and as directed
M&L Point Wiring using approved Colour Code as per IS with Zero hologen Flame Retardent (HFFR) Smoke Free, Non-toxic, Non-corrosive with Copper Conductor Cable 4.0 Sqmm (nominal area) with same size Earth Continuity Cable drawn in EXISTING ERW/GI CONDUIT of any description suitable for 16 Amp Socket Point and Making Good the disturbed surfaces of Walls, Celings, etc. (as per Site requirement), complete all as specified and as directed.
M&L Point Wiring with 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring using approved Colour Code as per IS with hologen Flame Retardent (HFFR) Smoke Free, Non-toxic, Non-corrosive with Copper Conductor Cable 1.5 Sqmm (nominal area) with same size Earth Continuity Cable drawn in EXISTING ERW/GI CONDUIT of any description suitable for LIGHT/FAN Point and Making Good the disturbed surfaces of Walls, Celings, etc. (as per Site requirement), complete all as specified and as directed.
M&L Point Wiring using approved Colour Code as per IS with Zero hologen Flame Retardent (HFFR) Smoke Free, Non-toxic, Non-corrosive with Copper Conductor Cable 2.5 Sqmm (nominal area) with same size Earth Continuity Cable drawn in EXISTING ERW/GI CONDUIT of any description suitable for 10 Amp Socket Point and Making Good the disturbed surfaces of Walls, Celings, etc. (as per Site requirement), complete all as specified and as directed.
S&F Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 2.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in EXISTING CONDUIT/PVC CASING & CAPING, complete all as specified and as directed.
S&F Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in EXISTING CONDUIT/PVC CASING & CAPING, complete all as specified and as directed.
M&L Flame Proof Sub-main Wiring with 2-Runs of 4.0 Sqmm Single Core, Halogen Free Flame Retardant (HFFR) insulated, multi-stranded, unsheathed 1100 Volt grade Copper Conductor Cable and 1-Run of 2.5 Sqmm Earth Continuity Wire of Single Core, Halogen Free Flame Retardant (HFFR) insulated, multi-stranded, unsheathed, 1100 Volt grade Copper Conductor Cable (Green Colour), drawn in/through EXISTING ERW/GI CONDUIT, complete all as specified and as directed.
M&L Flame Proof Sub-main Wiring with 2-Runs of 6.0 Sqmm Single Core, Halogen Free Flame Retardant (HFFR) insulated, multi-stranded, unsheathed 1100 Volt grade Copper Conductor Cable and 1-Run of 4.0 Sqmm Earth Continuity Wire of Single Core, Halogen Free Flame Retardant (HFFR) insulated, multi-stranded, unsheathed, 1100 Volt grade Copper Conductor Cable (Green Colour), drawn in/through EXISTING ERW/GI CONDUIT, complete all as specified and as directed.
S&F PVC Casing & Cappings of size 25mm, medium grade with all PVC Accessories and Making Good Surfaces to match the Exiting Treat-ment (as per Site requirement) including Taking down/out Old Unserviceable Casing & Cappings, complete all as per specified and as directed.
S&F PVC Conduit of size 25mm, medium grade with all PVC Accessories and Making Good Surfaces to match the Exiting Treat-ment (as per Site requirement) including Taking down/out Old Unserviceable Conduit, complete all as per specified and as directed.
S&F ERW Conduit of size 25mm, heavy duty with all Conduit Accessories and Making Good Surfaces to match the Exiting Treat-ment (as per Site requirement) including Taking down/out Old Unserviceable Conduit, complete all as per specified and as directed.
S&F ERW Conduit of size 32mm, heavy duty with all Conduit Accessories and Making Good Surfaces to match the Exiting Treat-ment (as per Site requirement) including Taking down/out Old Unserviceable Conduit, complete all as per specified and as directed.
S&F in repairs Switch Piano 6 Amp, Flush type, Single Pole, 1-way and , complete all as specified and as directed.
S&F in repais modular Switch 1 way 6 Amp, 1 module , complete all as specified and as directed.
S&F in repairs Switch Piano 16 Amp, Flush type, Single Pole, 1-way , complete all as specified and as directed.
S&F in repais modular Switch 1 way 16 Amp, 1 module , complete all as specified and as directed.
S&F in repairs Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin , complete all as specified and as directed.
S&F in repairs Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 6 Pin, complete all as specified and as directed.
S&F in repairs modular Socket Outlet 6 &16 Amp 2/3 pin combined 2 module, complete all as specified and as directed.
S&F in repairs Bell Push Button 6 Amp, Flush type suitable for Call Bell, complete all as specified and as directed.
S&F in repairs Modular Bell Push Button 6 Amp, 1 mosule suitable for Call Bell and , complete all as specified and as directed.
S&F in repairs Call Bell Electric Single Pole, 230 Volt, AC supply, Ding Dong type and , complete all as specified and as directed.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body and Fixing-in-repairs, complete all as specified and as directed.
S&F in repairs PVC rectangular block with cast iron junction box for mounting switches,sockets,fanregulator etc with 3 mm thick plastic laminated sheet cover of size up to 200 x 150 x 50 mm including cutting for mounting of switches and sockets, complete all as specified and as directed by Engineer-in-charge.
S&F in repairs PVC rectangular block with cast iron junction boxmounting switches,sockets,fanregulator etc with 3 mm thick plastic laminated sheet cover of size up to 250 x 200 x 50 mm including cutting for mounting of switches and sockets, complete all as specified and as directed by Engineer-in-charge.
S&F in repairs PVC rectangular block with cast iron junction box for mounting switches,sockets,fanregulator etc with 3 mm thick plastic laminated sheet cover of size up to 350 x 300 x 50 mm including cutting for mounting of switches and sockets, complete all as specified and as directed by Engineer-in-charge.
S&F in repairs Modular white plate frame 3 Module complete all as specfied and as directed by engineer-in-charge.
S&F in repairs Modular white plate frame 6 Module complete all as specfied and as directed by engineer-in-charge.
S&F in repairs Modular Metal flush box 3 Module complete all as specfied and as directed by engineer-in-charge.
S&F in repairs Modular Metal flush box 6 Module complete all as specfied and as directed by engineer-in-charge.
S&F Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type and Fixing-in-repairs, complete all as specified and as directed.
S&F in repairs Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 5.0 Watt LED 6500K and Connecting up with and including Copper Conductor Cable of size 23/0.0076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting , complete all as specified and as directed. MAKE : HAVELLS Cat Part No. LHEXBLP7IN1W005 or BAJAJ Cat Part NO. BCLSB 05 WH or HALONIX Cat Part No. Streak plus LED Batten (As approved)
S&F Flame Proof, Weather Proof LED Tube light fitting suitable for 1x18W (4 Feet) with Borosil Glass & connector suitable for 1x18 Watt LED Tube Light, product in Aluminium Die- Cast Alloy LM6 complete with Construction of Gr IIA, II B Tested and Certified CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked and Fixing-in-repairs, complete all as specified and as directed.
S&F in repairs Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 18 Watt LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.193 multi-stranded, 3 Core from Ceiling Rose to Light Fitting, connecting up, complete all as specified and as directed MAKE : HAVELLS Cat Part No.LHEXBLP7PN1W018 or BAJAJ Cat Part NO. BCLSB 18 WH or HALONIX Cat Part No. Streak plus LED Batten (As approved)
S&F in Repairs Decorative Ultra Modern LED 42W luminaire provide soft light glare free symmetrical illumination suitable for ceiling,Recessed panel comprising inbuilt occupancy with photo sensor with driver, complete all as directed. MAKE : HAVELLS Cat No. VENUSNEOHE2X2R42WLED830SMARTPLUS or BAJAJ Cat NO. BZRSQL 43W GZi WH Or SURYA (As approved)
S&F in repairs Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 10 Watt LED 6500K including Inverter LED Batten with lithium battery for Chargingb Time 8-10 hours and backup time 4 hours and connecting up with and including Copper Conductor Cable of size 23/0.193 multi-stranded, 3 Core from Ceiling Rose to Light Fitting, connecting up, complete all as specified and as directed MAKE : HAVELLS Cat Part No.LHEXACP7FN1W010 or HaALONIX LED Batten Inverter Prime 10W or C&S Electric Inverter Batten 10W (As approved)
S&F in Repairs LED Driver suitable for ceiling light 42 W Fixture size 595x595x65 mm Rectangular type having CRI 80 and CCT 6500 K. , complete all as specified and as directed. MAKE : HAVELLS Cat No LEDDRIVER36V42WS or its Equivalent C&S ELECTRIC/HALONIX /SURYA
S&F in repairs Flame Proof, Weather Proof Switch Socket with Plug Combined in LM6, Termination Box in LM6, 16 Amp, 415 Volt, TPN, 3 Pin and Earth Plug, Fully interlocked suitable for installation in hazardous as per IS-2147/ 62 Alluminium alloy/Cast Iron Neoprene Gasket Degree of Protection IP 65 and Certified CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked , complete all as specified and as directed.
S&F in repairs Switch Flame Proof Rotary type with Termination Box in LM6, 16 Amp, Single Pole, 250 Volt , complete all as specified and as directed.
S&F in repairs Flame Proof Weather Proof multi LED Flood Fitting 120 W, Product in Aluminium Die-cast Alloy LM6 Complete with Construction and Certified by CMRI DHANBAD with ISI marked and Elecrically Connecting up , complete all as specified and as directed.
M&L taking out existing Flame Proof Weather Proof Tube Light Fitting 2x36 Watt including Taking out Unserviceable conventional type Electronic Ballast, Starter, Tube Rod 36/40 Watt and retrofitting with New LED Light Fitting 2x18 Watt Complete with Glass of make Borosil including fixing with electrical connection with connector at original position and complete all as specified and as directed.
S&F in repair Flame Proof Weather Proof High-Bay LED 100 W Fitting , Product in Aluminium Die-cast Alloy LM6 Construction and Certified by CMRI DHANBAD with ISI marked and Elecrically Connecting up, complete all as specified and as directed.
S&F in repairs Flame Proof, Weather Proof Switch Socket with Plug Combined in LM6, Termination Box in LM6, 25 Amp, 415 Volt, TPN, 3 Pin and Earth Plug, Fully interlocked suitable for installation in hazardous as per IS-2147/ 62 Alluminium alloy/Cast Iron Neoprene Gasket Degree of Protection IP 65 and Certified CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked , complete all as specified and as directed.
S&F in repairs MCB Single Pole, 6 to 32 Amp (as directed), 240 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz including Connecting up , complete all as specified and as directed.
S&F in repairs MCB Single Pole & Neutral, 40 Amp, 240 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz including Connecting up , complete all as specified and as directed.
S&F in repairs MCB DB 8-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 63 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded/Concealed upto Wall surfaces including Connecting up with Existing Cable Incoming and Outgoing with Cable Lugs as per the Site requirement and and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to Match with the Existing Finishes , complete all as specified and as directed.
M&L taking out existing Flame Proof Weather Proof Tube Light Fitting 1x36 Watt including Taking out Unserviceable conventional type Electronic Ballast, Starter, Tube Rod 36/40 Watt and retrofitting with New LED Light Fitting 1x18 Watt, including refixing the same at original position and complete all as specified and as directed.
S&F in repairs Sheet Metal Enclosure, Single Pole with a 2-Pin and Earth Plug and Socket with and including 1 No. MCB Single Pole, 32 Amp, 240 Volt and Connecting up including , complete all as specified and as directed.
S&F in repairs MCCB 4 Pole, 415 Volt, Adjustable type, 100 Amps with breaking capacity 25 kA including Connecting up , complete all as specified and as directed.
S&Fin repairs Load Line DB 4-way Enclosure Double Door with MCCB 100 Amp rating, 16 kA, 4 Pole and suitable for 415 Volt 50 Hz AC Supply including Connecting up and Fixing-in-repairs, complete all as per specified and directed.
S&F MCB TP/TPN 4P, 63 Amp, 440 Volt, AC, 'C' Series for fixing on MCB DB’s, including Connecting up and Fixing-in-repairs, complete all as specified and as directed.
S&F PVC Flexible Pipe of size 25mm, with all PVC Accessories and Making Good Surfaces to match the Exiting Treat-ment including Taking down/out Old Unserviceable Conduit, complete all as per specified and as directed.
S&F Steel Flexible Pipe of size 25mm, with all PVC Accessories and Making Good Surfaces to match the Exiting Treat-ment including Taking down/out Old Unserviceable Conduit, complete all as per specified and as directed.
shiv shanker enterprises
SHIVAM ENTERPRISES
Ajay Enterprises
BS BUILDERS
AMBIKA ENTERPRISES
M/s Sheoran Brothers Builders And Engineers
M/s GURFATEH BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .