Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹22.2 L+₹52,257 (2.41%)Rejected-Finance 1ST FLOOR P R COMPLEX AT ROAD GUWAHATI 781 001 | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance Not Validated (Other than lowest bidder) | |
| 3 | L3₹23.7 L+₹2.0 L (9.01%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L3 | Rejected-Finance Not Validated (Other than lowest bidder) |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
17 Sept 2022, 6:00 pmClosed
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
REPAIR MAINT TO DG SET, CAPACITOR PANEL, STREET LIGHT REPAIR AND OTHER ALLIED WORKS AT OTHER THAN BASISTHA AREA UNDER GE GUWAHATI
2022_MES_546223_1
GE/GUW/37/8232 OF 2022-23
Open Tender
Civil Works
Item Rate
150 days
GUWAHATI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE GUWAHATI
₹48,000
Yes
7 Nov 2022
18 Aug 2022
19 Sept 2022
18 Aug 2022
17 Sept 2022
5 Sept 2022
18 Aug 2022 - 25 Aug 2022
Amount
Repair/Servicing of Diesel Engine Make : Kirloskar, Model No. EA 20 directly coupled with alternator of 15 KVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed. Note: (i)New Spares as required shall be measured and paid separately under item nos 2 to 9 as “Supply only” and cost of repairing id deemed to be inclusive in the unit rate quoted) (ii) Work shall be carried out through Original manufacturer or their autorized dealer, cetificate of the same shall be produced commencement of work (iii) Proper record of testing shall be maintained as directed by Engg-In-Charge (iv) Quoted rate is inclusive of necssary oiling and greasing, cotton ware, brushes etc and T&P required for the same
Supply only Air filter element
Supply only Fan belt
Supply only Fuel Filter
Supply only Lub Oil Filter
Supply only Feul pipe
Supply only copper washer
Supply only Exhaust fan (heavy duty)
Supply only AVR 3 Phase 15 KVA
Repair/Servicing of Diesel Engine Make : Kirloskar Green Model No. EA 20 directly coupled with alternator of 20 KVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed. Note: (i)New Spares as required shall be measured and paid separately under item nos 11 to 17 as “Supply only” and cost of repairing id deemed to be inclusive in the unit rate quoted) (ii) Work shall be carried out through Original manufacturer or their autorized dealer, cetificate of the same shall be produced commencement of work (iii) Proper record of testing shall be maintained as directed by Engg-In-Charge (iv) Quoted rate is inclusive of necssary oiling and greasing, cotton ware, brushes etc and T&P required for the same
Supply only Air filter element
Supply only Fan belt
Supply only Fuel Filter
Supply only Lub Oil Filter
Supply only Feul pipe
Supply only copper washer
Supply only AVR 3 Phase 20 KVA
Repair/Servicing of Diesel Engine Make : Greaves Ltd, Model No. 3YWAK directly coupled with alternator of 25 KVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed. Note: (i)New Spares as required shall be measured and paid separately under item nos 19 to 25 as “Supply only” and cost of repairing id deemed to be inclusive in the unit rate quoted) (ii) Work shall be carried out through Original manufacturer or their autorized dealer, cetificate of the same shall be produced commencement of work (iii) Proper record of testing shall be maintained as directed by Engg-In-Charge (iv) Quoted rate is inclusive of necssary oiling and greasing, cotton ware, brushes etc and T&P required for the same
Supply only Air filter element
Supply only Fan belt
Supply only Fuel Filter
Supply only Lub Oil Filter
Supply only Feul pipe
Supply only copper washer
Supply only AVR 3 Phase 20 KVA
Repair/Servicing of Diesel Engine Make : Kirlosker Bliss(Engine Ser No. ZKR3A0141AB02A-002) directly coupled with alternator of 140 KVA capacity, draining out the existing engine oil from the bottom of the oil sump and checking the entire serviceablity system of DG set testing and commissioning the same at site complete all as specified and as directed. Note: (i)New Spares as required shall be measured and paid separately under item nos 27 to 30 as “Supply only” and cost of repairing id deemed to be inclusive in the unit rate quoted) (ii) Work shall be carried out through Original manufacturer or their autorized dealer, cetificate of the same shall be produced commencement of work (iii) Proper record of testing shall be maintained as directed by Engg-In-Charge (iv) Quoted rate is inclusive of necssary oiling and greasing, cotton ware, brushes etc and T&P required for the same
Supply only Air filter element
Supply only Fuel Filter
Supply only Lub Oil Filter
Supply only Auto Start Relay
Disconnecting and dismantling including taking down carefully radiator assembly from 140 KVA DG Set for cleaning soldering including servicing dully disconnecting all water hose and other mechanical supports, transporting the radiator assembly to work shop, opening into parts cleaning the radiator fans with cleaning such as cotton waste cotton rags and soda water etc. soldering/brazing the broken/leakage fins and reassembling the same after replacement of defective spares and transporting the same from workshop to site and mounting its to original position including testing etc. complete all as directed.
Disconnecting and taking down carefully defective self starter of 24 volt capacity of 140 KVA DG Sets duly disconnecting all electrical cable connections and mechanical supports, transporting the same to civil authorised work shop and dismantling and opening into parts of self starter for assessing the defects and damaged parts and rectifying the defects by changing the defective spares including testing the same after replacement of defective spares and bring back the self starter from workshop to site and re-install the same to its original position and reconnect all disconnected connections and mechanical supports etc. all as specified and as directed..
Supply & fix in repair, brass battery terminals (Set of two) complete all as specified and as directed.
Disconnecting and taking down carefully defective fuel injection pump assembly of 140 KVA diesel generating set(Make Kirloskar Bliss) duly disconnecting all mechanical supports and opening in authorised work shop opening the FIP assembly and cleaning the spares and drying up the same sort out the defective parts and reassembling FIP after replacement of defective spares and taken back the FIP from work shop and reinstalled in existing position duly reconnect all disconnected mechanical supports and fuel lines etc. all as specified and as directed. Note: (i)New Spares as required shall be measured and paid separately under item nos 35 & 36 as “Supply only” and cost of repairing id deemed to be inclusive in the unit rate quoted) (ii) Work shall be carried out through Original manufacturer or their autorized dealer, cetificate of the same shall be produced commencement of work
Supply only Feul injector Nozzle of 140 KVA DG Set
Supply only Injector Claw of 140 KVA DG Set
Supply only Engine Oil suirable for DG Set (K-Oil 15W/40) in 20 Ltrs Container complete all as specified and as directed.
S&F in repair, Battery, 12 Volts, AH-180, plate -25, suitable for DG Set including initial charging.complete all as specified and as directed. Make: Exide, Model No-IN1800 plus or equivalent as approved by GE from list of makes
S&F in repair, Battery, 12 Volts, AH-105, suitable for DG Set 63 KVA to 125 KVA including initial charging complete all as specified and as directed. Make: Exide, Model No-GP 115E41L or equivalent as approved by GE from list of makes
Disconnecting and taking down carefully defective fuel injection pump assembly of 15/20/25 KVA diesel generating set(Make Kirloskar Green) duly disconnecting all mechanical supports and opening in authorised work shop opening the FIP assembly and cleaning the spares and drying up the same sort out the defective parts and reassembling FIP after replacement of defective spares and taken back the FIP from work shop and reinstalled in existing position duly reconnect all disconnected mechanical supports and fuel lines etc. all as specified and as directed. Note: (i)New Spares as required shall be measured and paid separately under item nos 41 to 42 as “Supply only” and cost of repairing id deemed to be inclusive in the unit rate quoted) (ii) Work shall be carried out through Original manufacturer or their autorized dealer, cetificate of the same shall be produced commencement of work
Supply only Feul injector Nozzle of 15/20/25 KVA DG Set
Supply only Injector Claw of 15/20/25 KVA DG Set
Supply only distilled water in 1Ltr packed bottle suitable battery all as per sample of approved make, complete all as specified and directed.
Supply only Coolent suirable for DG Set in 5 Ltrs Container complete all as specified and as directed.
Discnnecting electrically of Automatic power factor correcting panle (APFC panel ), of 125/100 kVAr capacity by taking out the enclosure including all components ,checking of power factor correction capacitors, APFC relay, capacitor duty contactors complete and refixing the same after duly repaied and replacement of unserviceable components/parts and testing of power factor after reparing complete all as specified and directed by Engr-in charge. Note: (i)New Spares as required shall be measured and paid separately under item nos 46 to 56 as “Supply only” and cost of repairing id deemed to be inclusive in the unit rate quoted) (ii) Work shall be carried out through Original manufacturer or their autorized dealer, cetificate of the same shall be produced commencement of work
Supply only power factor correction capacitors heavy duty cylindrical (Gas filled) 2.5 KVAr, 440 Volts, complete all as specified and directed.
Supply only power factor correction capacitors heavy duty cylindrical (Gas filled) 5 KVAr, 440 Volts, complete all as specified and directed.
Supply only power factor correction capacitors heavy duty cylindrical (Gas filled) 7.5KVAr, 440 Volts, complete all as specified and directed.
Supply only power factor correction capacitors heavy duty cylindrical (Gas filled) 20 KVAr, 440 Volts, complete all as specified and directed.
Supply only Capacitor duty contactor 30 KVAr , 415V , 3 Ph , 50 Hz Type MO C33.5, built in auxiliary contacts 1 NO, complete all as specified and directed.
Supply only LED type RYB indicating lamps (Set of three)
Supply only 6 Amps control fuse links and base
Supply only 16 Amps control fuse links and base
Supply only 32 Amps control fuse links and base
Supply only MPX-25, 25 Amps, TP, 415 Volts, Power Contactor
Supply only MPX-12, 12 Amps, TP, 415 Volts, Power Contactor
Taking down existing LED light fitting and replacing the burnt/unserviceable Drivers of capacity 25/30 Watt (Drivers shall be existing make of LED light fittings) and refixing the same in the existing pole and connecting up complete all as specified and directed.
Taking down existing LED light fitting and replacing the burnt/unserviceable Drivers of capacity 45/60 Watt (Drivers shall be existing make of LED light fittings) and refixing the same in the existing pole and connecting up complete all as specified and directed.
Taking down existing LED light fitting and replacing the burnt/unserviceable Drivers of capacity 90/120 Watt (Drivers shall be existing make of LED light fittings) and refixing the same in the existing pole and connecting up complete all as specified and directed.
S&F in repair, Post top lantern LED type 40 Watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp and connecting up with and including two core PVC insulated coppper conductor cable of 2.5 Sqmm complete all as specified and directed
S&F in repair, LED street light fitting 35 Watt 230 Volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and connecting up with and including two core PVC insulated coppper conductor cable of 2.5 Sqmm complete all as specified and directed
S&F in repair, LED street light fitting 60 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and connecting up with and including two core PVC insulated coppper conductor cable of 2.5 Sqmm complete all as specified and directed
S&F in repair, LED street light fitting 90 Watt 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and connecting up with and including two core PVC insulated coppper conductor cable of 2.5 Sqmm complete all as specified and directed
S&F in repair, LED flood light 120 watt 230 volts AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and connecting up with and including two core PVC insulated cppper conductor cable of 2.5 Sqmm complete all as specified and directed.
S&F in repair, 40mm bore GI pipe bracket (Light Grade) of length 2 mtrs bent to shape and fixed with 25mm x 4mm MS flat with necessary nuts, bolts, washers etc, as required and painting with two coats of syntheic enamel paint over a coat of primer anf fixed to pole complete all as specified and as directed.
S&F in repair, 50mm bore GI pipe bracket (Light Grade) of length 2 mtrs bent to shape and fixed with 25mm x 4mm MS flat with necessary nuts, bolts, washers etc, as required and painting with two coats of syntheic enamel paint over a coat of primer anf fixed to pole complete all as specified and as directed.
S&F in repair 4 Sq.mm size two core PVC insulated cppper conductor cable of for connection from junction box to street light fittings run through pole complete all as specified and as directed.
M&L thermpolastic cable junction box IP55 with metric knocknouts for cable entry and 4 way terminal of size 167mm x 125mm x 82mm fixed in position with aluminum clamps of size 25mm x 3mm and necssary nuts and bolts complete all as specified and directed.
M & L preparation of old painted surfaces of LT steel tubular pole 9.00 m long, cross arms, bracings, supports, clamps, back plate with nut bolts washers and providing one coat of aluminium paint including numbering and making strips in circular shape of diameter 150 mm black colour letter of hight 50 mm complete all as directed by Engr in Charge not exceeding 150 mm upto 1.5 mtr above ground level with alternate layer of yellow and black paint complete all as specified & as directed.
M&L for trimming of tree branches (by taking proper shut down from Sub-Station) near LT/HT over head lines upto 3 m clearance around the line on all sides including removing from site all as required and directed. (Note : T&P and ladders will be arranged by the contractor at his own cost)
M&L Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron earth lead wire of 4 sqmm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismentaling old unserviceable ones complete all as specified and directed.
Taking out old unserviceable UG cable of any size or description including taking out old brick protection complete all as directed.
Excavation in trenches not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.
M&L sand cushioning in cable trenches over & under the cable, with river washed coarse sand (of approved source) as per standard practice with proper compaction complete all as specified and directed.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 3½ core complete all as specified and as directed.
M&L steel tubular swaged poles, complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9.00 meter long, inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint including preparation of surfaces and making strip 150mm wide in alternate layer of black and yellow syntheic enamel paint upto 1.5 metre above Coping, including dismanting old unserviceable pole, complete all as specified and as directed.(The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161) NOTE : Earthwork, cement concrete will be measured and paid seperately under appropiate items
M & L Plain cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate)as in coping of poles including all necessary formwork complete all as specified & as directed.
M&L Plain cement concrete (1:4:8) type-D2 with using 40 mm graded crushed stone aggregate as in mass concrete etc complete all as specified and as directed.
M&L for Plain cement concrete (1:3:6) type-C2 with using 40 mm graded crushed stone aggregate as in foundation for pole/stay and mass concrete etc complete all as specified and as directed.
M/S PANKAJ SUPPLY SYNDICATE
M/S SEWAK SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .