Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.5 LAdmitted-Finance HOUSE NO 3 ANANDA NAGAR SIXMILE KAMRUP ASSAM 781022 UDYAM AS 03 0004106 | KAMRUP METRO | ASSAM | 781022 | -10.11% | ₹2.5 L | L1 | Admitted-Finance |
| 2 | L2₹2.6 LAdmitted-Finance | -5.70% | ₹2.6 L | L2 | Admitted-Finance |
| 3 | L3₹3.1 LAdmitted-Finance | +13.85% | ₹3.1 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical F 238 239 1ST FLOOR PALAM CORPORATE PLAZA PALAM VIHAR GURGAON HARYANA 122017 UDYAM HR 05 0014058 06AAGCD0484L1ZI R M MII STATUS AS NOT VERIFIED | GURUGRAM | HARYANA | 122017 | - | - | - | Rejected-Technical Rejected |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Others-Registration copy not uploaded and Payment to AO not deposited, hence the tender is hereby rejected. |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
17 Feb 2026, 3:00 pmClosed
SE CIVIL JVVNL
SE CIVIL JVVNL RAM MANDIR BANI PARK JAIPUR
P/F FRP fencing work at various places at Karauli city (Phase- II)
2026_JVVNL_536570_7
E-NIT 33/2025-26
Open Tender
Civil Works
120 days
Karauli city (Phase- II)
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
AO(O and M),JVVNL, Bharatpur Through NEFT/RTGS/IMP
₹56,000
Yes
23 Feb 2026
8 Feb 2026
18 Feb 2026
8 Feb 2026
17 Feb 2026
8 Feb 2026
PART-A (Bldg.)
B-1/1.8 : Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or rains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils.
B-3/3.1.2 : Providing and laying in Position Cement Concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
B-11/11.29:- Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge).
B-14.2.1: Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. : 1: 3: 6 or richer mix.
B-1/1.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
B-1/1.1 : Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed : All kinds of soil
B-12/12.46: Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : B-12/12.46.1: Two or more coats on new work
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
PART- B (Item Rate Basis)
Providing and Fixing of Fibre Reinforced Polymer/Plastic (FRP) Fencing for 11/0.4 KV transformers or 33 KV substations, comprising panels measuring 2.00 meters in height and up to 1.50 meters in length. The fencing shall be in yellow/green/pink/grey, as directed by the Engineer-in-Charge (EIC). The fencing includes vertical posts made of 50x50x4 mm hollow square sections with a height of 2.70 meters, grouted in 1:2:4 cement concrete (holdfasts and cement concrete paid separately). The spacing between vertical posts shall not exceed 1.5 meters and must be provided at all corners. The mesh consists of 24 mm outer diameter hollow cylindrical sections with a 3 mm thickness, placed vertically at 75 mm center-to-center intervals, and a horizontal 40x40mm hollow square section with a 3 mm thickness, all enclosed within a 40x40 mm hollow square pipe frame with a 3 mm thickness. The panels are secured to the vertical posts using stainless steel bolts. The fencing includes a single entry gate, with a height of 2.00 meters and a width up to 1.50 meters, as per site requirements, fitted with stainless steel hinges and aldrops. The gate must also feature a screen-printed nameplate with "JVVNL" and a danger sign on an SMC sheet. The vertical posts and panel sections to be manufactured using an automatic pultrusion process, incorporating at least 45% fiberglass reinforcement within a polyester-based thermoset resin. The material meets the following specifications: heat deflection temperature 2170°c (IS:13411), self-extinguishing flame resistance (S:4249), and non-melting characteristics (IS:13360), with a density 2 2000 kg/m². The fencing must also be resistant to chemicals, have a high-gloss finish, and be weatherproof to ensure durability in various environmental conditions. The quality must ensure good fit and finish, with proper strength as per the direction of the EIC. The job includes all necessary loading, unloading, transportation, labor, tools, safety equipment, and installation with stainless steel bolts, clamps and fasteners (paid separately), completed as per the EIC's direction. During installation, all safety protocols must be strictly followed, particularly when working near live electrical equipment. The mode of measurement for this fencing will be in the length of fencing per meter
Disposal of rubbish un-wanted material dismanted material away from site at appropirate place including all lead and lift, loading unloading, transportatoin labour etc. As per direction of Engineer in charges.
P/F stainless steel bolts 150mm long threaded at both sides for fastening members of FRP Fencing fastenend with washer and nuts at both side for extra strengthening of fencing wheever required and direction of E/I
Providing and fixing Ush ape MS Clamp 200mm long 50mm wide and 1mm thick with 2 holes to accomodate fasteners 65mm long along with 2 nos fastener of 65mm in length i/c all material, labour, T&P complete in all respect and direction of E/|
Supply stacking and spreading of graded crusher brocken hard stone aggregate fee from organic matter including stacking & spreading in yard / trenches as per the standard specification of size 40mm to 63 mm incl. all lead & lift, transportation, labour, loading, unloading & T&P required for gravelling work as per direction if Engineer in charge incl. dressing & leveling.
Re-arranging of cable loops of 33/11 KV i/c levelling of ground, for graveling and fencing work around transformer at various locations i/c shifting the cables using safety gears, gloves complete, Shifting work only to be done during shutdownand under the direction of E/1.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.22 MB
Tendernotice_2.pdf
PDF • 2.31 MB
BOQ_956030.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid