Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.7 LAccepted-AOC NO 920 10TH MAIN 1ST BLOCK GANANABHARATHI LAYOUT KENGERI BANGALORE 560060 | BENGALURU RURAL | KARNATAKA | 560060 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹49.8 L+₹4.1 L (8.86%)Rejected-Finance | L2 | Rejected-Finance Other Than Lowest | |
| 3 | L3₹49.9 L+₹4.2 L (9.17%)Rejected-Finance | L3 | Rejected-Finance Other Than Lowest | |
| 4 | L4₹51.3 L+₹5.5 L (12.1%)Rejected-Finance | L4 | Rejected-Finance Other Than Lowest | |
| 5 | L5₹51.7 L+₹6.0 L (13.0%)Rejected-Finance | L5 | Rejected-Finance Other Than Lowest |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
18 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BRICHGUNJ
GE BRICHGUNJ PORT BLAIR - 744103
PROVN OF STORAGE ACCN AND CERTAIN LBW WORKS UNDER GE BRICHGUNJ PORT BLAIR
2024_MES_642816_2
8436A
Open Tender
Civil Works
Item Rate
180 days
GE BRICHGUNJ
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Brichgunj
₹96,000
Yes
30 Mar 2024
4 Mar 2024
20 Mar 2024
4 Mar 2024
18 Mar 2024
12 Mar 2024
Amount
M&L Surface dressing n exc 15 cm deep and getting out in soft loose Soil
M & L Excavating over areas, n exc 1.5 m deep and getting out in any type of Soil.
All as per item no 2.00 but add for each additional 1.5m or part thereof in depth beyond the first 1.5 m and getting out in any type of soil.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm all as specified.
M&L Cement concrete in foundations, filling and mass concrete type D-2 1:4:8 (40mm graded aggregate).
M&L Reinforced cement concrete (design mix M-30 grade using 20mm graded aggregate) in Foundations footings, plinth beams, bases for columns, etc and mass concrete.
M&L Reinforced cement concrete (design mix M-30 grade using 20mm graded aggregate) above top of footings including attached pilasters and buttresses.
M&L Reinforced cement concrete (design mix M-30 grade using 20mm graded aggregate) Columns, pillars, piers, posts and struts.
M&L Reinforced cement concrete (design mix M-30 grade using 20mm graded aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span.
M&L Reinforced cement concrete (design mix M-30 grade using 20mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.
M&L Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm
M&L Removing excvated soil to a distance n.exc 50 m and depositing as directed
M&L Formwork flat or curved to sides of concrete foundations, footings, bases of columns, and plinth beams and similar work vertical or to batter
M&L Formwork flat or curved to to sides of pillars, posts, struts, piers, columns and stanchions
M&L Formwork flat or curved to sides and soffits offloor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvesincluding sup- ports, overhangs, etc. also splays between floors and beams, etc.
M&L Formwork flat or curved to Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item no 17.00 here in before but 6mm to 8mm dia
M&L pre-cast cement concrete masonary in PCC 1:3:6 type C1 using 20mm graded aggregate with solid block, exceeding 10cm in width setting in CM 1:6 complete.
M&L for 40mm thick Damp proof course in cement concrete 1:2:4 type B-O to horizontal or vertical surface including necessary formwork
M&L for 15mm thick rendering in two layers of 10mm thick backing coat inCM 1:6 and 5mm thick floating coat in CM 1:4 mixed with water proofing compound on all external wall surfaces/ RCC roof surface all as specified and as directed by Engg-in-Charge
M&L for 10mm thick rendering in CM 1:6 on all internal wall surfaces all as specified and as directed by Engg-in-Charge
M&L for rendering 5mm thick in CM 1:3 on soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like all as specified and as directed by Engg-in-Charge
M&L Filling under floors or in foundations including watering and consolidation
M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 10cm thick, watered and rammed to a true surface
M&L 100mm thick PCC 1:4:8 Type D-2 as in sub base for floors.
M&L 40mm thick Cement concrete type B-0,1:2:4 (12.5mm gradedaggregate) as in plinth protection
M & L for 40mm thick PCC 1:2:4 type Bo (using 12.5mm coarse aggregate) as in floors including finishing even and smooth using extra cement all as specified.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including prepartion and applying priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces
M & L for applying two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surfaces of wall including preperation of surfaces complete all as specificed and as directed
M & L for applying two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surfaces of Ceilings, soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like including preperation of surfaces complete all as specificed and as directed
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. Note: (i) The said item has to be carriedout in different quarters located in areas under occupied condition.(ii) The working hours shall be planned such a manner that there should not be any disturbance to the occupants.(iii) The rate quoted shall include considering the above.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge.Note: (i) The said item has to be carriedout in different quarters located in areas under occupied condition.(ii) The working hours shall be planned such a manner that there should not be any disturbance to the occupants.(iii) The rate quoted shall include considering the above.
S&F 150mm long extruded aluminium alloy anodised handles fabricated type
S& F Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing clips to sheet cast or extruded sections and fixing bolt or cast aluminium alloy
S&F Aluminium anodised barrel tower bolt of extruded section of size 150mm long
Supply only 12 mm thick Prelaminatd particle board, exterior grade, prelaminated exterior grade on both sides with decorative choice lamination and fixed to aluminium frames complete all as specified and as directed by Engineer -in-Charge.
S&F in repair Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type B-21 100mm Size
Supply only 4mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed by Engineer-in-charge.
Supply only aluminium alloy wire mesh 0.45 nominal dia of wire and average width of aperture 1.40mm fixed with aluminium wire staples complete all as directed by Engineer-in-Charge.
Supply only Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type C-21 75mm Size
Supply only adjustable aluminium powder coated window handle with hook of size 125mm complete all as specified and as directed.
S&F anodised aluminium grill (anodised transparent or dyed to required shad according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to poper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
S & F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachemtns attachment
S & F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240
Preparation of new or previously untreated steel surfaces & applying a two coats of synthetic enamel paint over a coat of red oxide primer over 10cm in width or girth,not otherwise described.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
M&L Surface dressing n exc 15 cm deep and getting out hard/Dense Soil
M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 10cm thick, watered and rammed to a true surface
M&L 100mm thick PCC 1:4:8 Type D-2 as in sub base for floors.
M&L for glazed, polished Chequered cement concrete tiles 300mm x 300mm x 25mm thick, set, jointed and pointed in neat cement slurry, including screed bedding layer in cement mortar 1:6, 20mm thick in flooring complete all as specified and as directed by Engr-In-Charge
Dismantling boarding, any description, fixed in any position with nails all as specified and directed.
Supply only 4mm thick ACP (Aluminium Composite panel) fixed to aluminium frames/ shutters for complete all as specified and as directed by Engineer in Charge.
S & F 100 mm long Aluminium, anodised, barrel tower bolts of extruded section.
S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised.
S&F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type C-21 75mm Size
M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 sqm n.exc 0.11 sqm, in floors etc set and jointed in neat cement slurry in floors and pointed with coloured cement to match the colour of tiles incl screed bed or bedding layer of mortar 15mm thick in CM 1:4 for laying floor finishes complete all as specified.
M & L for Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick backing coat in Cm 1:3 all as specified.
M & L for point wiring complete with single core multi stranded Copper conductor FRLS cable of size 1.5 sqmm PVC insulated unsheathed 1100 volt grade in and including PVC conduit suitable size including Tee junction bends etc in wall/fixed on ceiling and PVC switch board box type complete all as specified and as directed by Engineer-in-Charge. One light point controlled by one way switch
One ceiling fan point controlled by one way switch
One three pin 5 Amp switch socket cum on Independent board
Supply and fix of switch piano flush type single pole one way 5 Amp all as specified and directed.
S & F switch socket combination 2 in 1, 5 Amps, 5 pin multipurpose, flush type, 230 Volts Make: Anchor/ Leader/ Maru
Supply and fix ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specfified and as directed by Engineer-in-Charge
Supply and fix fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge
Supply and fix ceiling fan suitable for working on AC 230 volts, 50 Hz,1200 mm sweep 5 star rating with down rod and canopy colour of milky white including suitable fan hook/ clamp for fixing of fan on ceiling complete all as specified and as directed.
S & F Recess mounting type LED Panel lights fitting of dimension 2x2 feet, 35/36W, 220V, AC with driver including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed and as specified by the engineer in charge.
S&F 35 W pressure dia cast aluminium housing IP66 protection with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs complete all as as specified and as directed by Engineer-in-Charge
Supply and fix MCB single pole, 240 volts, 5 to 32 Amps, all as specified and as directed.
Supply and fix MCB SPN 240 volts, 5 to 32 Amps, all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 3 Core 10 sq mm.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out Soft/loose Soil
Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cm soil / hard dense soil.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point.Soft Soil / hard dense soil
Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked all specified and directed.
S&F tube light grade galvanised with all fittings laid in trenches for 50 mm dia bore.
Material and Labour for cutting bituminous road at a width not more than 30cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with cement concrete 1:2:4, type, B-2 to match the existing surfaces of the road all as specified and as directed by Engineer in charge.
VAJRA CONSTRUCTIONS
Forge Engineering & Electricals
V D JADEJA
RAJESH ENTERPRISE
Harsh Infrastructure
KUZHIKKAL ENTERPRISES
ANAND REFRIGERATION
SAPTHAGIRI CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .