Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-Finance | L1 | Accepted-Finance 1st Lowest Bidder | |
| 2 | L2₹2.0 L+₹25,760 (15.1%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest Bidder |
| Sl No | Description | Qty | Unit | M/S PRABHATT ENGINEERING WORKS L2 | M/s Meera Enterprises L1 |
|---|---|---|---|---|---|
| 1.00Following works are to be carried out at 132 KV S/s Nautanwa for retrofitting of Isolator disconnectors arm with 1 new design high capacity Isolators disconnectors of 145 KV side including cost of men, misc. consumables, T&P etc. to complete the job satisfactory. | |||||
| 2.00 | Safe carriage of 03 Nos. 145 KV Line side Isolator and 02 Nos. Bus side Isolators from 132 KV S/s FCI to 132 KV S/s Nautanwa after proper stacking and loading (distance approx. 80 Km and weight approx. 1400 Kg.) | 1 | Job | 10,000 ₹10,000 | 9,400 ₹9,400 Lowest |
| 3.00 | Opening of old and existing jumpers between old main bus-I and Bus-II and line side Isolators and between bus Isolator to Circuit Breaker. | 24 | Nos. | 500 ₹12,000 | 485 ₹11,640 Lowest |
| 4.00 | Dismantling of old existing different make Isolator installed in 132 KV switchyard by opening of its all accessories including arms , connecting pipes, male and female jaws of all three phase , P.I. and its mechanism box , safe lowering of all components , safe shifting of all dismantled components of different make Isolators to store as per guidance of supervising engineer including all cost of labour and T&P (All 03 phase of Isolator considered as 01 Job) | 4 | Nos. | 8,500 ₹34,000 | 7,600 ₹30,400 Lowest |
| 5.00 | Erection of New 132 KV Isolator of 132 KV switchyard of its complete mechanism like P.I. , Isolator arm assembly box and then checked complete alignment of new Isolator (work will be carried out as per drawing . Laying and termination of different size of control cable for NO/NC status from Isolator to control room panel as per direction of supervising engineer (if required). | 4 | Nos. | 10,000 ₹40,000 | 9,700 ₹38,800 Lowest |
| 6.00 | Jumparing of conductor as per standard specification in between bus to bus isolator and between bus isolators to circuit breaker etc. by proper cutting , bending , tightening of conductor by using necessary connectors to be provided by department. | 24 | Nos. | 500 ₹12,000 | 400 ₹9,600 Lowest |
| 7.00 | Overhauling work of 145 KV side LSI , BSI which includes replacement of defective part of Isolator (rotating head , Isolator connector provided etc.) cleaning of their P.I. , Oiling , greasing and finally setting proper alignment for their smooth operation (All materials provided by contractor). | 6 | Nos. | 6,000 ₹36,000 | 4,800 ₹28,800 Lowest |
| 8.00 | Overhauling work of 33 KV side LSI , BSI which includes replacement of defective part of Isolator (Jaw , Isolator connector provided etc.) cleaning of their P.I. , Oiling , greasing and finally setting proper alignment for their smooth operation (All materials provided by contractor). | 4 | Nos. | 3,000 ₹12,000 | 2,400 ₹9,600 Lowest |
| 9.00 | Major overhauling of mechanism of 145 KV CB of CGL make installed at 132 KV Bus coupler Bay and 132 KV TBC Bay at 132 KV S/s Nautanwa. Work includes overhauling of control block assembly, Opening latch , closing latch , support latch , anti-pumping assembly. Opening , cleaning and greasing of motor charging system , replacement of worn out part. Checking of shock absorber, closing damper etc. Checking of mechanism assembly for wear and tear , rectification / repairing of worn out parts. Checking of limit switch , power contactors , auxiliary contactors for proper functioning . Checking and retightening of all electrical connections, replacement of defective left and right spring of driving pawls . Measurement of closing and tripping time of circuit breaker. The work also include replacement of old contactor and MCB as per instruction of JE. | 2 | Nos. | 20,000 ₹40,000 | 16,000 ₹32,000 Lowest |
Tender Value
₹2.3 L
EMD Value
₹2,500
Closing Date
4 Dec 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle, UPPTCL, Pareshan Bhawan, Mohaddipur, Gorakhpur
WORK OF REPLACEMENT AND OVERHAULING OF 06 NOS. 145KV ISOLATOR AND 02 NOS. 145KV CIRCUIT BREAKERS OF 132KV NAUTANWA-MAINAHIYA (NEPAL) BAY I AND II AT 132KV S/S NAUTANWA , MAHARAJGANJ UNDER ETD-II, GORAKHPUR
2025_UPTCL_1089981_1
E-Tender No. 55-ETC(G)/2025-26
Open Tender
Electrical Works
Item Rate
60 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
SE, ETC, Gorakhpur
₹2,500
20 Jan 2026
12 Nov 2025
5 Dec 2025
12 Nov 2025
4 Dec 2025
12 Nov 2025
Following works are to be carried out at 132 KV S/s Nautanwa for retrofitting of Isolator disconnectors arm with 1 new design high capacity Isolators disconnectors of 145 KV side including cost of men, misc. consumables, T&P etc. to complete the job satisfactory.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.51 MB
BOQ_2001516.xls
BOQ • 0.39 MB
Technical55.pdf
Tender Documents • 0.89 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .