| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹38.1 L+₹32,743 (0.87%)Rejected-Finance | L2 | Rejected-Finance LOWEST BIDDER OTHER THAN | |
| 3 | L3₹41.5 L+₹3.7 L (9.79%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L3 | Rejected-Finance LOWEST BIDDER OTHER THAN | |
| 4 | L4₹44.2 L+₹6.4 L (16.9%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance LOWEST BIDDER OTHER THAN | |
| 5 | L5₹47.7 L+₹9.9 L (26.1%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L5 | Rejected-Finance LOWEST BIDDER OTHER THAN |
Tender Value
₹38.7 L
EMD Value
₹77,480
Closing Date
18 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO HT FEEDERS 3 AND 4 OF MPH AND CPH UNDER GE UTILITY UDHAMPUR
2021_MES_489063_1
CWE/U(U)-70/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
GE UTILITY UDHAMPUR
₹77,480
Yes
24 Dec 2021
18 Nov 2021
20 Dec 2021
18 Nov 2021
18 Dec 2021
6 Dec 2021
60 days
Amount
Steel tubular swaged pole erected to truly vertical or planted as strut complete with 6 mm thick MS Base plate,welded to pole,finial taper cap, bolts, nuts, screws,11 Mtr long, type 410 SP - 55,including drilling of holes of required size for fixing of cross arms,painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the portion embedded in concrete, and marking pole no. with black paint at suitable height all as specified and directed by Engineer-in-Charge including dismantling/ taking down existing pole. Note:- (a) The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of BOQ (b) Test certificate of Steel tubular pole shall be submitted to department before installation at site
Taking down the unserviceable iron acessories from pole structures and Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections ( flat, angle, channel) including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified.
Taking down the unserviceable lightning arrestors 2/4 pole structures .Supply and Fix lightining arresters expulsion type complete with all fittings suitable for 11000 volts grade conforming to IS-3070 part-I, transmission class, discharge capacity 65KA, complete all as specified and as directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to galvanised iron earth strip 32 x 6mm by means of bolts,check nuts and washers and earth strip protected by provision of GI pipe light grade 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test point with fixing arrangement, funnel, wire mesh and earth work in any type of soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I all as specified and testing on completion.
Srl item No 4 Contd … Note : 1. Note :- Cost of GI earth strip & protection pipe upto 7.5 mtr is deemed to be included in unit rate. 2. On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
ACSR conductor of required size of over head lines on poles including streching, tightening of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor all as specified and directed by Engineer- in- Charge including dismantling/ taking down existing ACSR conductor.
Cable jointing kit for 11KV (Earthed) grade cable for End joint heat shrinkable type joint outdoor termination complete with jointing material and acessories suitable for 3 core XLPE armoured aluminium conductor cable 120 sq.mm in repair complete all as specified & directed by Engineer-in-charge
Taking down the u/s SF-6 switchgear from the 11 KV system. Supply , install, testing and commissioning of 11KV SF-6 switchgear,630 Amps, 21KA/3 sec, indoor duty internal are IAC AFL 21 KA for 1 sec for Gas tank, SF6 gas insulated , one side extensible 4 way, manual operated ring ment unit. Operated in combination of 1 No load break switchg as incommer and 3 nos load break switch as out goings consisting of copper busbar in SF6 insulated 304(Non-ferrite Non Magnetic grade) complete all as specified & directed by Engineer-in-charge . Stainless steel enclosure of thickness 2.5 mm with manometer fixed. Switchgear shall confirming to IEC-62271-100, IEC-62271-200-2003& IEC 60694-1996. The RMU shall be along the cable chamber to put to an outdoor enclosure to have ingress protection of minimum IP 54. Should have voltage presence indicator and each LBS feeder should have fault passage indicator. Switchgear shall accomodated with syntheic rubber mats 2m x 1 m x 0.5mtrs -01 No . Note: 1. Old u/s circuit breaker shall be deposited in AGE E/M E/S store yard.
Cable jointing kit for 11KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and acessories suitable for 3 core XLPE armoured aluminium conductor cable 120 sq.mm in repair complete all as specified & directed by Engineer-in-charge
Taking down the unserviceable HT Cable in the existing electrical network system of ( Central Power House to JNE Substation and MPH to JNE Substation ) any of location . Supply, laying & testing cable XLPE cable earthed system insulated heavy duty screened PVC bedded, galvanised strip or wire armoured electric power cable with stranded aluminium conductor 11000 volts grade (with earth system) as per IS, cross sectional area 120 sqmm 3 core complete all as specified and directed.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr in depth for laying of under ground cable and getting out in soft/ loose soil complete all as specified & directed by Engineer-in-charge
Description all as above but depth exceeding 1.5 mtr but not exceeding 3.0 mtr complete all as specified & directed by Engineer-in-charge.
Returning filling in excavated soil in trenches including spreading , levelling, watering and well ramming in layers n exc 25 cm thick complete all as specified & directed by Engineer-in-charge
Removing of excavated soil to a distance n exc 50mtr and deposited where directed at a level not exceeding 1.5 mtr above starting point complete all as specified & directed by Engineer-in-charge
Plain cement concrete (1:3:6 ) type C-2 (using 40mm graded crushed stone aggregate) as in foundation/ mass concrete complete all as specified & directed.
Providing, cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles including use of form work and finishing all exposed faces of concrete as per clause 4.11.16.2 (a) & (d) of SSR Part-I complete all as specified.
Supply and lay DWC (Double wall corruguated) pipe 90/76 mm conforming to IS: 14930/ IS 16205 for protection of HT Cable 120sq.mm, ISI Marked, including necessary snap-fit coupler required for fixing complete all as specified & directed by Engineer-in-charge
Material and labour for road cutting for laying of HT/LT Cables / Pipes and making good the disturbed surfaces as equal to existing road finishes including refilling the excavated material, compacting , WBM and black top carpeting with bitumen & aggregates complete all as specified & directed by Engineer-in-charge
Switch Air break gang operated tripple pole structure mechanically operated from ground level mounted on and including 12 No insulators and steel frame, out door type, suitable for vertical installation, single break, provided with locking arrangement consisting of MS channel, HT post type insulator copper alloy high pressure assembly with drop out fuse assembly with fuse carrier fuse element 5-20 amp mounted on insulator and operating rod of 25mm dia medium grade GI pipe complete conforming to IS-1018 of 1972 with continuous current rating upto 400 amps and voltage 11 KV including testing and commissioning all as specified including dismantling of existing air break switch.
proach associates
MOHAN LAL AND SONS
K S BUILDERS
FANGALIA TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .