Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 CrAccepted-AOC HOUSE NO 20 BAGHARBARI VIDYANAGAR 2 PANJABARI GUWAHATI ASSAM 781037 | KAMRUP METRO | ASSAM | 781037 | ₹1.7 Cr | 1 | Accepted-AOC Accepted |
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
4 Dec 2023, 2:00 pmClosed
Chief Engineer, PWD(Roads), Assam
O/o the Chief Engineer, PWD(Roads), Assam
Construction of (i) Dinesh Ojha Path (ii) Tribeni Path under Mukhya Mantri Nagaria Pakki Path Nirman Asoni for the year 2023-24.
2023_PWD_34196_5
MMNPPNA/GMC(Re-bid-Lot-1,2)
Open Tender
Civil Works – Roads
Item Rate
120 days
Guwahati
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,800
₹3.8 L
Yes
18 Sept 2024
24 Nov 2023
4 Dec 2023
24 Nov 2023
4 Dec 2023
24 Nov 2023
24 Nov 2023 - 4 Dec 2023
Amount
Dismantling of cement concrete pavements by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto the lead of 1000m , stacking serviceable materials and unserviceable materials separately. Cement concrete
Removal of unserviceable materials with disposal upto 1000 metres ( Removable of unserviceable soil including excavation, loading and disposal upto 1000 metres lead but excluding replacement by suitable soil which shall be paid separately as per clause 305)
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 1 as per Technical Specification Clause 404. WBM Gr-III
Providing and laying Interlocking Concrete Block Pavement with M40 grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage.
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Providing 'Sparkle Solar Roads Studs, manufactured by Tata B.P Solar India Ltd. Of size (125mm x 125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDs-three on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour. Weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty anf free maintenance from one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician). a)Bi-directional Stud
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Cleaning and de-silting of road side drains/ cross drains etc. by mechanical means with adequateroad safety measures by providing caution boards/ safety ribbons/ proper barricading where necessary/ proper lighting if necessary etc without damaging the footpaths/ slabs/ road surfaces etc including immediate disposal of the semi liquid/ silt/ garbage/ floating materials/ polythene etc taken out from the drains/ culverts etc upto a lead of 20.00 km from the site within 24 hours as directed keeping the road surface/ footpath etc clean and as directed by the department. De-siltation work will have to be carried out as and when necessary as directed by the Engineer-in-Charge
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. 600mm equilateral triangle
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. 9ii) 600mm circular.
Direction and place identification signs upto 0.9 sqm size board Retro-Reflectorised Traffic signs . Providing and erecting direction and place identification retro-refectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting, 2mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post (75 x 75 x 6)mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete (450 x 450 x 600)mm below ground level as per approved drawing and technical specification Clauses 1701
Re-construction of RCC Load Bearing Drain (0.90 x 0.90)m Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved materials. (I) Ordinary Soil Quantity (A) Manual means (Depth upto 3m) (without de-watering)
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803,1202 & 1203 (A) With crushed stone. 'PCC Grade M15
Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification steel shuttering formwork. (E)R.C.C. Grade M20 (a) Height upto 5m Using concrete Mixer
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, .complete as per drawing and technical specifications.
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification. (B) Sandy materials
Repairing of Brick Drain: Brick masonry work in cement mortar 1:3 in foundation complete excluding pointing and plastering, as per drawing and technical specifications.
Plastering with cement mortar (1:3 ) on brick work in sub-structure as per Technical specifications
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification steel shuttering formwork. (E)R.C.C. Grade M20 (a) Height upto 5m
Construction of RCC Cross Culvert (1.10m x 1.10m): Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. (i) Lime/Cement Concrete (ii) By Mechanical Means (A) Cement Concrete
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved materials. (I) Ordinary Soil Quantity (A) Manual means (Depth upto 3m) (without de-watering)
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803,1202 & 1203 (A) With crushed stone. 'PCC Grade M15
Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications
Plain/reinforced concrete in substructure complete as per drawings and technical specifications Clause 802,804, 805, 806, 807 ,1202 & 1204 (A) With crushed stone. IV) RCC M25 i) for height upto 5m
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, .complete as per drawing and technical specifications.
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification. (B) Sandy materials
Chamber protection of Jica (2.00m x 2.00m): Dismantling of cement concrete pavements by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto the lead of 1000m , stacking serviceable materials and unserviceable materials separately. Cement concrete
Reinforcement in Super Structure: Supplying, fitting and placing TMT bar reinforcement in sub-structure including splicing complete as per drawing and technical specifications. (b) other make ISI approved TMT reinforcement bar of Fe-415 N/mm2
Plain/reinforced cement concrete, in Sub Structure complete as per drawing and technical specification. Using Steel Shuttering F) RCC Grade -M25. Using Concrete mixer
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .