| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-Finance 26 8 2 PUNE MUMBAI ROAD OPP B U BHANDARI SHOWROOM EKTA PARK SOCIETY WAKDEWADI PUNE 411 003 | PUNE | MAHARASHTRA | 411003 | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹38.9 L+₹65,511.98 (1.71%)Rejected-Finance FLAT NO 8 205 SNO 296 2 DIVINE HOMES PORWAL ROAD KSHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance not being lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (CME) Khadki
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
Repair/cleaning of existing sewage line, soil waste pipes, septic tank etc in certain OTM accn, 269 Engr Regt and CEDU at CME
2023_MES_599596_2
8441/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (CME) Khadki
Class D, a(I)
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (CME) Khadki
₹90,000
Yes
27 Jun 2023
9 Jun 2023
27 Jun 2023
9 Jun 2023
23 Jun 2023
11 Jun 2023
Amount
Cleaning of bore blocked sewage lines in any depth any dia by pressure jet by using mechanical/ hydraulic pressure using vehicle type hydrulic methods or modern methods from manholes or manholes to cleaning eye or cleaning eye to clean eye until the smooth flow of sewage line is restored including taking out sludge in semi liquid stage including all water effluence etc refixing man hole cover and removing all materials from site of work upto outside CME complex land and depositing in excavated earth pit of suitable size including supply and sprinkling bleaching powder and covering sludge with earth after removal of blockage etc complete all as directed.
Note: 1. These complaints are to be attended on day to day basis with sufficient manpower and tools.
Note: 2. Quoted rate is deemed to be inclusive of earthwork & excavation, sprinkling sufficient bleaching powder including transporting the sludge & other materials in closed vehicle.
Note: 3. Contractor shall employ min 02 Nos. safaiwala daily for under mention locations. (a) 01 No. for OTM accn & (b) 01 No. for 269 ER & 262 CEDU area .
Note: 4.In case contractor fails to deploy said number of safaiwala for any of the days for attending complaints for whatsoever reasons in that case, recovery @ Rs. 600/Safaiwala shal be recovered from RAR/FB being paid.
Cleaning of manholes blockages (including WC, urinal, kitchen and bathrooms) systematically using necessary tools mechanical ways with suction motor vehicle mounted and/ or manually such as by rodding, bamboo fanti and disc of required size (with safety measure gas etc) flushing with water the pipe until water clear the flow of sewage from both side between two adjacent manhole/gully traps or WC/ NT of any size or depth, taking out sludge in semi liquid stage/roots of tree etc. including all water effluences etc and removing all material to outside CME complex land and depositing in earth pit of suitable size including supply of sprinkling bleaching powder and covering sludge with earth after removal of blockage etc complete all as specified and directed.
Note :1. These complaints are to be attended on day to day basis with sufficient manpowder and tools.
Note: 2. Quoted rate is deemed to be inclusive of earthwork & excavation, sprinkling sufficient bleaching powder including transporting the sludge & other materials in closed vehicle.
Note: 3. Contractor shall employ min 02 Nos. safaiwala daily for under mention locations. (a) 01 No. for OTM accn & (b) 01 No. for 269 ER & 262 CEDU area .
Note: 4. In case contractor fails to deploy said number of safaiwala for any of the days for attending complaints for whatsoever reasons in that case, recovery @ Rs. 600/Safaiwala shal be recovered from RAR/FB being paid.
Cleaning of nahani trap of any size.
Cleaning of gully trap of any size
Excavation in trenches not exc. 1.50m wide and 1.50m depth for foundation, man hole etc and getting out in soft/loose soil all as specified and directed.
All as per item No.6 above, but in hard/dense soil
Exacavation in over area not exceeding 1.5m deep and getting out in soft/loose soil complete as specified and directed by Engr-in-Charge.
All as per item No.8 above, but in hard/dense soil
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete as specified and directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete as specified and directed by Engr-in-Charge.
Demolition of brick/ stone/PCC block masonry built in cement mortar/cement lime mortar all as specified and directed by Engr-in-charge.
M&L for precast plain cement concrete solid block masonry type C-1 1:3:6 (using 20 mm graded stone aggregate), built in CM 1:6 exc, 10 cm width all as specified and directed by Engr-in-charge
M&L for rendering 15 mm thick cement plaster in CM 1:6 on concrete surface/ stone masonry surface or other than fair face of brick work incl finishing even and smooth without using extra cement complete as specified and directed by Engr-in-Charge.
Taking down cement plaster of any description incl raking out joints, hacking for key and scrubbing down with water etc complete as specified and directed by Engr-in-Charge.
M&L in repair for RCC drain pipes 150mm, class NP-3 laid in trenches and jointed complete with collar all as specified complete as specified and directed by Engr-in-Charge.
All as item No.15 above, but 200mm dia
M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in concrete bed to RCC drain pipes including packing under and haunching against side of pipes with concrete after they are laid and jointed, dia of pipe 150mm complete as specified and directed by Engr-in-Charge.
All as item No.17 above, but 200mm dia
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil complete as specified and directed by Engr-in-Charge.
Removing excavated material (soil) not.exceeding 50m and deposited where directed at a level not exceeding 1.5 m above the starting point complete as specified and directed by Engr-in-Charge.
M&L for precast RCC concrete cover slab of sizes (600 mm x 450 mm x 75mm, 600 mm x 600 mm x 75mm and 900 mm x 450 mm x 75mm thick) for man holes with provision of collar all around to house the cover slab and collar fixed to wall of manhole in cement mortar 1:6 having smooth surface finish complete including taking down old unserviceable concrete cover slab all as specified and directed by Engineer-in Charge.
M & L for TMT bar 5mm dia & over upto and including 10mm dia in cut to length, bend to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for PCC (1:2:4) type B1, using 20mm graded stone aggregate as in coping, bands, plinth courses, parapets, kerbs etc like incl weathering, slightly rounded or chamfered throating complete all as specified & directed.
Bailing out waste water from septic tank well upto top of sludge/broken media mechanically using suction motor vehicle mounted and removing the same out of CME complex including removal of sludge etc. complete all as specified and directed by Engineer -in- Charge for 10 users
All as item No. 24 above, but 25 user.
All as item No. 24 above, but 50 user.
All as item No. 24 above, but 100 user.
M & L cutting hole in brick walls/stone walls exc one brick but not exc 2 bricks for any purpose and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed by Engineer-in Charge.
M & L PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in sub base of floors 75mm thick complete all as specified and directed by Engineer-in Charge.
M&L for cement concrete 50mm thick 1:3:6 type C-1 (using 20mm graded stone aggregate) as in floor, finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in Charge.
M&L coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick set pointed with neat cement slurry with grey cement and pigment in floorsover and including 15mm thick screed bed in cm 1:4 complete including taking down old unserviceable tiles all as specified and directed.
M & L machine pressed precast concrete interlocking paver block with grey cement and no pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with glossy finish, colour shade over and including 25mm thick sand cushioning as directed by Engineer-in-Charge including taking down old unserviceable paver block. Note : Rate quoted shall deem to include for sand, spreading and levelling of sand for cushioning.
Cleaning and removing all scale and dirt duly spraying diluted bleaching powder and rubbing with wire brushes etc from tank any type (AC or PVC) and from mouth of circulating pipes etc exc 250 ltr n.exc 500 tlr capacity including write date of cleaning and next due date also with white synthetic enamel paint and complete as specified and directed by Engr-in-Charge.
..-do- all as per item No.33 above, but exc 500 litre and n.exc 1000 litre capacity.
M&L for bituminous road cutting to a width of 45cm and depth of 50 cm for laying of sewage pipe, culverts etc and making good with PCC (1:3:6) type C1 (using 20mm graded stone aggregate ) all as specified and directed.
M&L for vitrified tiles of 400x400mm, 12mm thick mat rough finish, breaking strength =1500N, modulas of rupture 38N/mm2, bulk density =2.2 per gm/cc, colour resistance to uv light as in parking tiles etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete including taking down old unserviceable tiles all as specified and directed.
S&F in repair 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
All as per item No.37 above, but 110mm complete all as specified and directed.
S&F in repair 75mm PVC (SWR) bend any radius complete all as specified and directed
All as per item No.39 above, but 110mm dia complete all as specified and directed.
S&F in repair 75mm PVC (SWR) junction single (single T) equal or unequal complete all as specified and directed.
All as per item No.41 above, but 110mm bore of pipe complete all as specified and directed.
M&L in repair 75mm PVC (SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed.
All as per item No.43 above, but 110mm complete all as specified and directed.
S&F in repair 75mm PVC (SWR) vent cowl complete all as specified and directed.
All as per item No.45 above, but 110mm complete all as specified and directed.
(Applicable for above all items)
Contrator has to employ skilled/unskilled tradesman with adequate experience & required documents to be submitted to office.
Labour should wear contractors uniform with firm logo, failing which recovery should be made.
Minimum of 02 x teams of each trades shall be available for maint of urgent nature whenever called upon of any trade, failing which recovery will be initiated for not employing adequate labour at site.
Site clearance shall be done by contractor after finishing work and obtain the signature of occupant as the site clearance has done. The same shall be verified and put up before issue of completion certificate
All Scarps will be done with mechanical scaper
Mechanical scaper should be deposited in our store at the time of sample approval
BSK Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .