Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAdmitted-Finance HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L1 | Admitted-Finance | |
| 2 | L2₹35.7 L+₹3.8 L (11.8%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹40.0 L+₹8.1 L (25.3%)Admitted-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L3 | Admitted-Finance | |
| 4 | L4₹41.7 L+₹9.8 L (30.6%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹45.0 L+₹13.1 L (41.0%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Indu Electricals L2 | SUN LIGHT HOUSE L6 | Universal refrigeration and Engineering Company L3 | SHILPA CONSTRUCTION COMPANY L4 | L and S ENTERPRISES L7 | omsai thermax engineers L1 | Haasith constructions L5 | SRI SAI ENTERPRISES L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Disconnecting and removing and replacing of the following unserviceable items from the Chiller of MEMS for smooth functioning complete all as specified and directed by the Engr-in-Charge. | |||||||||||
| 1.01 | Disconnecting and removing the un-serviceable EXV board of chiller unit fo Air cooled AC plant, from the existing position, supply and fixing in repairs new EXV board all as specified and directed by Engineer-in-charge. | 1 | Each | 3,60,000 ₹3,60,000 | 4,00,800 ₹4,00,800 | 3,20,250 ₹3,20,250 | 3,30,000 ₹3,30,000 | 4,00,790 ₹4,00,790 | 2,70,000 ₹2,70,000 Lowest | 3,51,000 ₹3,51,000 | 4,10,000 ₹4,10,000 |
| 1.02 | Disconnecting and removing the unserviceable EXV Motor from its existing position and replace with new EXV Motor in repairs all as specified and directed | 1 | Each | 1,22,500 ₹1,22,500 | 1,64,000 ₹1,64,000 | 1,09,800 ₹1,09,800 | 1,14,000 ₹1,14,000 | 1,63,000 ₹1,63,000 | 81,000 ₹81,000 Lowest | 1,18,950 ₹1,18,950 | 1,63,500 ₹1,63,500 |
| 1.03 | Disconnecting and removing the unserviceable EXV Cable from its existing position and replace with new EXV Cable in repairs all as specified and directed | 1 | Each Job | 40,000 ₹40,000 | 50,000 ₹50,000 | 36,600 ₹36,600 | 42,000 ₹42,000 | 46,000 ₹46,000 | 33,300 ₹33,300 Lowest | 43,582 ₹43,582 | 46,250 ₹46,250 |
| 1.04 | Disconnecting and removing the unserviceable Refrigerent Sensor from its existing position and replace with new Refrigerent Sensor in repairs all as specified and directed | 2 | Each | 44,000 ₹88,000 | 10,000 ₹20,000 Lowest | 36,600 ₹73,200 | 42,000 ₹84,000 | 47,000 ₹94,000 | 36,000 ₹72,000 | 43,680 ₹87,360 | 47,350 ₹94,700 |
| 1.05 | Disconnecting and removing the unserviceable Liquid Line Paper Filter from its existing position and replace with new Liquid Line Paper Filter in repairs all as specified and directed | 2 | Each | 500 ₹1,000 Lowest | 9,000 ₹18,000 | 5,945 ₹11,890 | 5,100 ₹10,200 | 9,000 ₹18,000 | 25,000 ₹50,000 | 5,937 ₹11,874 | 9,350 ₹18,700 |
| 1.06 | Disconnecting and removing the unserviceable Flow Switch from its existing position and replace with new Flow Switch in repairs all as specified and directed | 1 | Each | 3,000 ₹3,000 | 14,500 ₹14,500 | 6,310 ₹6,310 | 6,000 ₹6,000 | 8,000 ₹8,000 | 2,700 ₹2,700 Lowest | 6,678 ₹6,678 | 8,125 ₹8,125 |
| 1.07 | Disconnecting electrically and mechanically the condensor fan motor from the existing position and rewinding, varnishing, insulation, ovening, greasing to the condensor fan motor, replacing of bearings all as specified and directed. | 6 | Each Job | 12,000 ₹72,000 | 18,500 ₹1,11,000 | 11,500 ₹69,000 | 11,400 ₹68,400 | 15,000 ₹90,000 | 9,000 ₹54,000 Lowest | 12,265 ₹73,590 | 15,241 ₹91,446 |
| 1.08 | Disconnecting and removing the unserviceable Fan Motor MCB from its existing position and replace with new Fan Motor MCB in repairs all as specified and directed | 3 | Each | 18,000 ₹54,000 | 19,000 ₹57,000 | 17,475 ₹52,425 | 17,700 ₹53,100 | 20,000 ₹60,000 | 14,400 ₹43,200 Lowest | 18,135 ₹54,405 | 20,125 ₹60,375 |
| 1.09 | Inspection charges for testing, programming, commissioning etc for AC plant at MEMS Lab | 1 | Each Job | 75,000 ₹75,000 | 1,00,000 ₹1,00,000 | 6,950 ₹6,950 Lowest | 81,600 ₹81,600 | 90,000 ₹90,000 | 63,000 ₹63,000 | 85,995 ₹85,995 | 90,850 ₹90,850 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Oct 2025, 6:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIRS AND REPLACEMENT OF CONTROL SWITCH GEAR ELECTRIC CONTROL VFD AUTOMATION SYSTEM SCALE PREVENTER AT RCI UNDER GE I RND RCI HYDERABAD
2025_MES_722850_2
8300
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(I) R AND D RCI
MES enlisted Class D category c i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT.
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹90,000
Yes
4 Nov 2025
29 Sept 2025
15 Oct 2025
29 Sept 2025
13 Oct 2025
1 Oct 2025
Amount
Disconnecting and removing and replacing of the following unserviceable items from the Chiller of MEMS for smooth functioning complete all as specified and directed by the Engr-in-Charge.
Disconnecting and removing the un-serviceable EXV board of chiller unit fo Air cooled AC plant, from the existing position, supply and fixing in repairs new EXV board all as specified and directed by Engineer-in-charge.
Disconnecting and removing the unserviceable EXV Motor from its existing position and replace with new EXV Motor in repairs all as specified and directed
Disconnecting and removing the unserviceable EXV Cable from its existing position and replace with new EXV Cable in repairs all as specified and directed
Disconnecting and removing the unserviceable Refrigerent Sensor from its existing position and replace with new Refrigerent Sensor in repairs all as specified and directed
Disconnecting and removing the unserviceable Liquid Line Paper Filter from its existing position and replace with new Liquid Line Paper Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable Flow Switch from its existing position and replace with new Flow Switch in repairs all as specified and directed
Disconnecting electrically and mechanically the condensor fan motor from the existing position and rewinding, varnishing, insulation, ovening, greasing to the condensor fan motor, replacing of bearings all as specified and directed.
Disconnecting and removing the unserviceable Fan Motor MCB from its existing position and replace with new Fan Motor MCB in repairs all as specified and directed
Inspection charges for testing, programming, commissioning etc for AC plant at MEMS Lab
Disconnecting and removing and replacing of the following unserviceable items from the Chiller of Radar Seekar Lab for smooth functioning complete all as specified and directed by the Engr-in-Charge.
Disconnecting and removing the unserviceable fan contactors from existing position and replace with new Fan Contactors in repairs all as specified and directed
Disconnecting and removing the unserviceable fan MCCB from its existing position and replace with new Fan MCCB in repairs all as specified and directed
Disconnecting electrically and mechanically the condensor fan motor from the existing position and rewinding, varnishing, insulation, ovening, greasing to the condensor fan motor, replacing of bearings all as specified and directed.
Disconnecting and removing the unserviceable drier filter from its existing position and replace with new Drier Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable external oil filter from its existing position and replace with new External Oil Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable ball valve from its existing position and replace with new Ball Valve in repairs all as specified and directed
Disconnecting and removing the unserviceable screw compressor oil from compressor and replace with new Screw Compressor Oil in repairs all as specified and directed
Disconnecting and removing the unserviceable temperature sensor from its existing position and replace with new Temperature Sensor in repairs all as specified and directed
Inspection charges for testing, programming, commissioning etc for AC plant at Radar Seekar Lab
Disconnecting and removing and replacing of the following unserviceable items from the Chiller of EHSV Lab for smooth functioning complete all as specified and directed by the Engr-in-Charge.
Disconnecting and removing the unserviceable Chiller Main Module from existing position and replace with new Chiller Main Module in repairs all as specified and directed
Disconnecting and removing the unserviceable EXV Module from its existing position and replace with new EXV Module in repairs all as specified and directed
Disconnecting and removing the unserviceable Temperature Sensor from its existing position and replace with new Temperature Sensor in repairs all as specified and directed
Disconnecting and removing the unserviceable Flow Switch from its existing position and replace with new Flow Switch in repairs all as specified and directed
Inspection charges for testing, programming, commissioning etc for AC plant at EHSV Lab
Disconnecting and removing and replacing of the following unserviceable items from the Chiller of Q&R Lab for smooth functioning complete all as specified and directed by the Engr-in-Charge.
Disconnecting and removing the unserviceable Fan Board from existing position and replace with new Fan Board in repairs all as specified and directed
Disconnecting and removing the unserviceable SCPM Board from its existing position and replace with new SCPM Board in repairs all as specified and directed
Disconnecting and removing the unserviceable LP Transducer from its existing position and replace with new LP Transducer in repairs all as specified and directed
Disconnecting and removing the unserviceable HP Transducer from its existing position and replace with new HP Transducer in repairs all as specified and directed
Disconnecting and removing the unserviceable Internal Oil Filter from its existing position and replace with new Internal Oil Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable External Oil Filter from its existing position and replace with new External Oil Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable Flow Switch from its existing position and replace with new Flow Switch in repairs all as specified and directed
Disconnecting electrically and mechanically the condensor fan motor from the existing position and rewinding, varnishing, insulation, ovening, greasing to the condensor fan motor, replacing of bearings all as specified and directed.
Disconnecting and removing the unserviceable Screw & Bearing from its existing position and replace with new Screw & Bearing in repairs all as specified and directed
Disconnecting and removing the unserviceable Fan Motor MCB from its existing position and replace with new Fan Motor MCB in repairs all as specified and directed
Inspection charges for testing, programming, commissioning etc for AC plant at Q&R Lab
Disconnecting and removing and replacing of the following unserviceable items from the Chiller of Navigation Complex for smooth functioning complete all as specified and directed by the Engr-in-Charge.
Disconnecting and removing the unserviceable TCPM Board from existing position and replace with new TCPM Board in repairs all as specified and directed
Disconnecting and removing the unserviceable EXV Board from its existing position and replace with new EXV Board in repairs all as specified and directed
Disconnecting and removing the unserviceable Temperature Sensor from its existing position and replace with new Temperature Sensor in repairs all as specified and directed
Disconnecting and removing the unserviceable 5/8th Ball Valve from its existing position and replace with new 5/8th Ball Valve in repairs all as specified and directed
Disconnecting and removing the unserviceable Oil Filter from its existing position and replace with new Oil Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable Compressor Oil from compressor and replace with new Compressor Oil in repairs all as specified and directed
Inspection charges for testing, programming, commissioning etc for AC plant at Navigation Complex
Disconnecting and removing and replacing of the following unserviceable items from the Chiller of IIR Seekar Lab for smooth functioning complete all as specified and directed by the Engr-in-Charge.
Disconnecting electrically and mechanically the condensor motor from the existing position and rewinding, varnishing, insulation, ovening, greasing to the condensor motor, replacing of bearings all as specified and directed.
Disconnecting and removing the unserviceable HP Switch from its existing position and replace with new HP Switch in repairs all as specified and directed
Disconnecting and removing the unserviceable LP Switch from its existing position and replace with new LP Switch in repairs all as specified and directed
Disconnecting and removing the unserviceable OSS Switch from its existing position and replace with new OSS Switch in repairs all as specified and directed
Disconnecting and removing the unserviceable Angle Valve from its existing position and replace with new Angle Valve in repairs all as specified and directed
Disconnecting and removing the unserviceable Copper Pipe from compressor line and replace with new Copper pipe in repairs all as specified and directed
Disconnecting and removing the unserviceable Flare Nuts from its existing position and replace with new Flare Nuts in repairs all as specified and directed
Disconnecting and removing the unserviceable Copper Tee from its existing position and replace with new Copper Tee in repairs all as specified and directed
Disconnecting and removing the unserviceable Voltage Protection Devise (VPD) from its existing position and replace with new Voltage Protection Devise (VPD) in repairs all as specified and directed
Disconnecting and removing the unserviceable Subzero from its existing position and replace with new Subzero in repairs all as specified and directed
Disconnecting and removing the burntout Copper 3 Core Cable, 1.5 Sqmm size with new Copper 3 Core Cable, 1.5 Sqmm size in repairs all as specified and directed
Disconnecting and removing the unserviceable Compressor Contactor from its existing position and replace with new Compressor Contactor in repairs all as specified and directed
Disconnecting and removing the unserviceable PVC / CPVC Pipe from its existing position and replace with new PVC / CPVC Pipe in repairs all as specified and directed
Disconnecting and removing the unserviceable MCCB, 250 Amps, 4P from its existing position and replace with new MCCB, 250 Amps, 4P in repairs all as specified and directed
Disconnecting and removing the unserviceable Chiller Pump Bearing from its existing position and replace with new Chiller Pump Bearing in repairs all as specified and directed
Opening of the screws, covers of the aircooled condensing units, Descaling of the aircooled condensing units to bring down the high pressure, Cleaning of the dust particles formed on the coil system with diluted 'ASFOCLEAN' chemical, Costic Soda by pouring on the coil with leg pump or mechanical system till the clearing of the dust on the coil as primary wash and detergent powder or surf water as final wash and testing complete of condensing units all as specified and directed.
Supply and Filling of Refrigerant gas R-134A / R-22 / 407 or as recommended by OEM.
Indu Electricals (BID ID -3448965)
Universal refrigeration and Engineering Company (BID ID -3449442)
SHILPA CONSTRUCTION COMPANY (BID ID -3449537)
Haasith constructions (BID ID -3449969)
SUN LIGHT HOUSE (BID ID -3449349)
L and S ENTERPRISES (BID ID -3449740)
SRI SAI ENTERPRISES (BID ID -3449333)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .