Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.3 LAccepted-AOC SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹20.7 L+₹2.4 L (13.2%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹21.3 L+₹3.0 L (16.6%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹23.1 L+₹4.8 L (26.3%)Rejected-Finance | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹23.8 L+₹5.5 L (30.3%)Rejected-Finance BHANDARI NIWAS BHARAT NAGAR TEH DISTT PATHANKOT PIN 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹98,800
Closing Date
6 Jun 2024, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPLACEMENT OF INTERNAL WIRING WITH REPLACEMENT OF FITTING AND FIXTURES, DB S, SUB MAIN WIRING, SERVICE CABLE AND CONNECTED WORKS AT MIRAN SAHIB UNDER GE JAMMU
2024_MES_651091_1
GEJC-01/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE Jammu
₹98,800
Yes
10 Jul 2024
10 May 2024
8 Jun 2024
10 May 2024
6 Jun 2024
24 May 2024
Amount
Attending of day to day complaints 24 X 7 Hours for internal electrification system of all type of electrical complaints and any type / nature of complaints at OTM, KLP and MD Accn and all as directed by MES representative of Miran Sahib. Notes: - (i) Contractor / his representative shall attend MES service centre daily routine complaints at 0900 hours to note down the complaints from concerned JE and shall submit compliance report at 1700 hours for the complaints given in the morning. (ii) Labour rates deemed to be included in the quoted rate in respect of relevant schedule of items. (iii) All types of T&P as required at site for the work shall be arranged by the contractor under his own arrangements, cost deemed to be included in quoted rates. (iv) A recovery @ Rs. 650/- per day per complaint shall be recovered from the contractor if complaint given to the contractor remains unattended / not rectified at the end of the day. (v) Contractor shall employee minimum of one electrician and one helper or relevant technician (for complaints) having adequate experience in the said field. (vi) Any type of complaints to be attended and record in complaint slip.
Taking down old unserviceable copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden / iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid / steel conduit and into existing cast iron / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Notes: - (a) Wiring shall be done by using proper colour coding including making the disturbed surface good. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description all as per Ser item No 3.00 here-in-before but for one 5 pin socket outlet 5 amps on the same board complete all as specified and as directed.
Description all as per Ser item No 3.00 here-in-before but for one 5 pin socket outlet, 5 amps, independent complete all as specified and as directed.
Description all as per Ser item No 3.00 here-in-before but for one 5 pin socket outlet, 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Supply only switch piano, flush type single pole, one way 5 Amp, 240 volts ISI marked complete all as specified and directed.
Supply only socket outlet 2 in 1, 3 pin, 5 A complete all as specified and directed.
Supply only switch socket outlet combined 5 pin 5 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply only switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply only socket outlet 3 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and directed.
Supply only switch piano, flush type single pole one way 15 Amps, 240 volts ISI marked complete all as specified and directed.
Supply only ceiling rose 3 terminal surface type complete all as specified and directed.
Supply only lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply only bell, AC 230 Volts single pole complete all as specified and directed.
Supply only bell push flush type single pole one way 5 amp complete all as specified and directed.
Supply only holder any type for batten fitting ISI marked complete all as specified and directed.
Supply only MCB single pole 6 to 32 Amps, 240 Volt 'B' series complete all as specified and directed.
Supply only SPN 32 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
Supply only insulation tape roll of different colours as per sample complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including new cast iron / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Notes: - (a) Wiring shall be done by using proper colour coding including making the disturbed surface good. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description all as per Ser item No 23.00 here-in-before but 5 Amp socket outlet on same board complete all as specified and as directed.
Description all as per Ser item No 23.00 here-in-before but socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.
Description all as per Ser item No 23.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Description all as per Ser item No 23.00 here-in-before but drawn through and including new surface conduit PVC rigid non metalic conduit 20 mm dia for socket outlet 5 amp independent board complete to accomodate the accessories for PVC Gang Box complete all as specified and as directed.
Description all as per Ser item No 23.00 here-in-before but drawn through and including new surface conduit PVC rigid non metallic conduit 20 mm dia for socket outlet 15 amp independent board complete to accomodate the accessories for PVC Gang Box complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including pressed steel with existing colour terminated boxes of modular metal flush boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following: - Notes: - (a) Suitable modular white cover sheets with frame as specified to be provided in replacement to mild steel / Galvanised sunken boxes and measured and paid separately as per relevant item. (b) Wiring shall be done by using proper colour coding including making disturbed surface good. (c) Earth wire shall be of green colour. (d) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description all as per Ser item No 29.00 here-in-before but 5 Amp socket outlet on same board complete all as specified and as directed.
Description all as per Ser item No 29.00 here-in-before but socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.
Description all as per Ser Item No 29.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Supply and fixing in replacement modular switch 1 way 6 A, 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement socket, 6 A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement socket 6 A / 16 A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box ½ module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 3 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 4 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 6 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 8 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 12 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 3 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 4 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 6 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 8 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 12 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud TPN 6 way 415 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed magnetic setting of capacity 125 Amps 16 KA complete all as specified and as directed.
Supply and fixing in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing SPN 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing 415 V, 10 KA 'B' curve TPN 40 to 125 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement for switch piano, flush type single pole one way 5 Amp, 240 volts complete all as specified and as directed.
Supply and fixing in replacement for switch piano, flush type single pole one way 15 Amps, 240 volts complete all as specified and as directed.
Supply and fixing in replacement socket outlet 2 in 1, 3 pin, 5 A 240 volts complete all as specified and as directed.
Supply and fixing socket outlet 5 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete all as specified and as directed.
Supply and fixing in replacement switch socket outlet combined 5 pin 5 amp flush type, 240 volts complete all as specified and as directed.
Supply and fixing in replacement switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 volts complete all as specified and as directed.
Supply and fixing for bell push, flush type single pole, 5 Amp, 240 volts complete all as specified and as directed.
Supply and fixing ceiling rose 3 terminal surface type complete all as specified and as directed.
Material and labour in replacement for lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Material and labour in replacement for self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
Supply and fixing in replacement LED light fitting 1 x 20 Watt, 220 Volt, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95, 100 Lumen / Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts 50 Hz complete all as specified and as directed.
Supply and fixing in replacement LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 Volt AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing in replacement bulk head luminaries IP-65 with opal diffuser 10 watt, 230 Volts LED type complete with 10 watt LED Bulb all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 Volt AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and as directed.
Supply and fixing in replacement calling bell Ding Dong / buzzer AC 230 Volts, single pole complete all as specified and as directed.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement copper cable for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed.
Material and labour in replacement copper cable for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed.
Material and labour for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 precast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed.
Supply and fixing in replacement unserviceable wooden / cast iron sunken box with new CRCA pressed steel terminal box of size 7X4' including taking down old complete with cemented and patch work all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement unserviceable wooden / cast iron sunken box with new CRCA pressed steel terminal box of size 4X4' including taking down old complete with cemented and patch work all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement unserviceable wooden / cast iron sunken box with new CRCA pressed steel terminal box of size 10X8' including taking down old complete with cemented and patch work all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (06 No's each) of size 8''X5'' all as specified and directed.
Supply and fixing in replacement Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (12 No's each) of size 12''X10'' all as specified and directed.
Supply and fixing in replacement Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (02 No's each) of size 5''X5'' all as specified and directed.
Supply and fixing in replacement plug top 15 Amps complete all as specified and directed.
Supply and fixing in replacement of Vertical Distribution Board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCB's and should be IP-43 protected with copper bus bars, neutral links, earthing bar all as specified and directed including taking down old unserviceable DB/MCB any type. Notes: - (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 volts with adjustable thermal settings. (ii) MCB's shall be measured and paid separately. (iii) TPN DB and MCCB should be of same make.
Supply and fixing in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 5 amp 240 volt alongwith switch piano 5 amp 240 volt complete all as specified and as directed.
Supply and fixing in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 5 amp 240 volt alongwith switch piano 15 amp 240 volts complete all as specified and as directed.
Supply and fixing in replacement of fancy light 9 watt for false ceiling complete all as specified and directed.
Hi Tech Engineers
BMMJ TRADERS AND ENGINEERS
N S MANHAS
M/s GIrdhari Lal Rakesh Kumar
Durga Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .