| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 CrAdmitted-Finance AIGAVAN UPARHAR DHARM RAJ MISHRA AIGAVAN UPARHAR MAHILA UPARHAR KARARI KAUSHAMBI UTTAR PRADESH 212216 UDYAM UP 46 0007784 | KAUSHAMBI | UTTAR PRADESH | 212216 | ₹6.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.3 CrAdmitted-Finance 2214 URBAN ESTATE JIND | JIND | HARYANA | 126101 | ₹6.3 Cr | L2 | Admitted-Finance |
| 3 | L3₹6.5 CrAdmitted-Finance | ₹6.5 Cr | L3 | Admitted-Finance |
| 4 | L4₹6.6 CrAdmitted-Finance FATEHABAD HGVY | PATIALA | PUNJAB | 140402 | ₹6.6 Cr | L4 | Admitted-Finance |
| 5 | L5₹6.9 CrAdmitted-Finance | ₹6.9 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Shiv Construction Company L1 | Ashok Kumar Garg L5 | OM Constructions L4 | M/s Vision India Infratech L3 | AJAY KUMAR CONTRACTOR L2 | M/S DDR Buildtech L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply of concealed box for fixing LED lights complete in all respects and as per directions of Engineer-in-charge | 298 | Each | 500 ₹1,49,000 | 150 ₹44,700 Lowest | 170 ₹50,660 | 160 ₹47,680 | 156 ₹46,488 | 179 ₹53,342 |
| 2.00 | Supply, installation, testing and Commissioning of street light in 32W LED IP66, MS decorative Pole in 3.5 mtr height and Double Arm Bracket in complete in all aspects with all accessories as per direction of Engineer In Charge. Make: Phillips, Vake, Havells etc. | 10 | Each | 3,000 ₹30,000 Lowest | 45,000 ₹4,50,000 | 46,350 ₹4,63,500 | 41,900 ₹4,19,000 | 41,600 ₹4,16,000 | 47,936 ₹4,79,360 |
| 3.00 | NS Perforated GI Tray with hangers and supports for copper piping (300 mm wide) | 50 | Metre | 1,000 ₹50,000 | 1,000 ₹50,000 | 1,055 ₹52,750 | 975 ₹48,750 | 950 ₹47,500 Lowest | 1,092 ₹54,600 |
| 4.00 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply :
Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to
operate up to 50 0C (out door ambient temperature) 1.5 TR with 5 Star BEE Rating | 4 | Each | 70,000 ₹2,80,000 | 35,000 ₹1,40,000 Lowest | 47,000 ₹1,88,000 | 46,000 ₹1,84,000 | 43,500 ₹1,74,000 | 52,487 ₹2,09,948 |
| 5.00 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable
upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply :
Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to
operate up to 50 0C (out door ambient temperature). 2.0 TR with 5 Star BEE Rating | 1 | Each | 90,000 ₹90,000 | 45,000 ₹45,000 | 46,000 ₹46,000 | 38,000 ₹38,000 Lowest | 48,500 ₹48,500 | 42,431 ₹42,431 |
| 6.00 | Supply, installation, testing and Commissioning of Centralised remote controller for operation and status monitoring of indoor units of ac | 1 | Nos. | 1,00,000 ₹1,00,000 | 50,000 ₹50,000 | 30,000 ₹30,000 | 43,212 ₹43,212 | 9,500 ₹9,500 Lowest | 46,000 ₹46,000 |
Tender Value
₹5.9 Cr
EMD Value
₹11.8 L
Closing Date
30 Jul 2026, 1:00 pmClosed
SANJEEV KUMAR
Municipal Corporation Faridabad
CONSTRUCTION OF COMMUNITY CENTRE AT SECTOR 16A, MC FARIDABAD.
2026_HRY_533494_1
202607CBCEAC 7776 4205 8693 D81A0DBCEAA8284ULB
Open Tender
Civil Works
Works
750 days
Faridabad (MC)
2 documents required · 2 mandatory
₹20,000
₹11.8 L
Yes
25 Aug 2026
3 Jul 2026
30 Jul 2026
3 Jul 2026
30 Jul 2026
3 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of concealed box for fixing LED lights complete in all respects and as per directions of Engineer-in-charge | 298 | Each | - | - |
| 2 | Supply, installation, testing and Commissioning of street light in 32W LED IP66, MS decorative Pole in 3.5 mtr height and Double Arm Bracket in complete in all aspects with all accessories as per direction of Engineer In Charge. Make: Phillips, Vake, Havells etc. | 10 | Each | - | - |
| 3 | NS Perforated GI Tray with hangers and supports for copper piping (300 mm wide) | 50 | Metre | - | - |
| 4 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply :
Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to
operate up to 50 0C (out door ambient temperature) 1.5 TR with 5 Star BEE Rating | 4 | Each | - | - |
| 5 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable
upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply :
Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to
operate up to 50 0C (out door ambient temperature). 2.0 TR with 5 Star BEE Rating | 1 | Each | - | - |
| 6 | Supply, installation, testing and Commissioning of Centralised remote controller for operation and status monitoring of indoor units of ac | 1 | Nos. | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
BOQ_612567.xls
BOQ • 0.26 MB
date0001.pdf
PDF • 0.02 MB
date0001.pdf
PDF • 0.02 MB
dateextend.pdf
PDF • 0.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].