Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC ROWRIAH KB ROAD PO CHALIHA JORHAT 785004 ASSAM | JORHAT | JORHAT | ASSAM | 785004 | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹19.2 L+₹1.5 L (8.27%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
18 Jan 2022, 6:00 pmClosed
GE (AF) JORHAT
GE (AF) JORHAT PIN-785005
REPAIR MAINTENANCE OF COOLING APPLIANCES ALL TYPES OF ACs WATER COOLERS REFRIGERATORS DEEP FREEZERS HUMIDIFIERS VOLTAGES STABILIZERS VARIOUS TYPES OF GEYSERS SOLAR HEATING SYSTEM UNDER AFH AND AFS OF GE AF JORHAT.
2021_MES_482150_2
8915/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) JORHAT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹36,000
Yes
1 Feb 2022
29 Dec 2021
20 Jan 2022
29 Dec 2021
18 Jan 2022
5 Jan 2022
Amount
M&L for servicing of 1.5/2.0/3.0 TR capacity window/split type AC after disconnecting from electric supply, opening suction & dicharge pipes of outer unit , and removing scratch, dust with iron brush,cleaning condessor unit,compressor, cooling coil/cleaning of fan blade/ cleaning of filter of inner unit etc,with water & air blower including (checking thermostate, starting capacitior, running capacitor) and reinstalling the same at the desired places complete all as specified and directed. Note:Refreigerant Gas shall be measured and paid under respective item here-in-after separately as required and as pre manufacturer instruction.
Taking down/up defective AC (Window/Split Type) 1.5 TR Capacity, Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt rotary type Compressor Sealed Unit and providing new Compressor of same Capacity and same make, Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas including re-connection of Electric Connections and Testing, complete all as specified and directed. MAKE : CAMIPRO/EMERSION/TECUMSEH Note:Refreigerant Gas shall be measured and paid under respective item here-in-after separately as required and as pre manufacturer instruction.
All as per Item No. 2 above but AC (Window/Split Type) 2.0 TR Capacity. Note:Refreigerant Gas shall be measured and paid under respective item here-in-after separately as required and as pre manufacturer instruction.
Taking down/up defective AC (Window/Split Type) 1.5 TR Capacity, Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt reciprocating type Compressor Sealed Unit and providing new Compressor of same Capacity and same make, Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas including re-connection of Electric Connections and Testing, complete all as specified and directed. MAKE : CAMIPRO/EMERSION/TECUMSEH Note:Refreigerant Gas shall be measured and paid under respective item here-in-after separately as required and as pre manufacturer instruction.
All as per Item No. 4 above but AC (Window/Split Type) 2.0 TR Capacity. Note:Refreigerant Gas shall be measured and paid under respective item here-in-after separately as required and as pre manufacturer instruction.
S&F Fan Motor of AC (Window/Split Type) 1.5 TR Capacity of approved Make and sample of required Size to suit existing AC including Taking out the unserviceable Fan Motor from AC complete all as specified and directed. MAKE : VOLTAS/LG/AMTEX/HITACHI/CARRIER/ BLUE STAR
S&F Air Circular Blower Fan Motor of AC (Split Type) 1.5 TR Capacity of approved Make and sample of required Size including Taking out unserviceable Air Circular Blower Fan Motor from AC complete all as specified and directed. MAKE : VOLTAS/LG/AMTEX/HITACHI/CARRIER/ BLUE STAR
S&F Air Circular Blower Fan Motor of AC (Split Type) 2.0/3.0 TR Capacity of approved Make and sample of required Size including Taking out unserviceable Air Circular Blower Fan Motor from AC complete all as specified and directed. MAKE : VOLTAS/LG/AMTEX/HITACHI/CARRIER/ BLUE STAR
S&F Remote Circuit Board including senser and display with Remote of Inverter AC (Split Type) 1.5/2.0 TR Capacity (as per Sample/ Site Requirement) and taking out unserviceable Remote Circuit Board, senser and display from AC, complete all as specified and directed. MAKE : AMTREX/LG/VOLTAS/HITACHI/CARRIER/ BLUE STAR
S&F Capacitor 36 mfd – 50 mfd of AC (Window/Split Type) 1.5/2.0 TR Capacity including Taking out unserviceable Capacitor from AC complete all as specified and directed. MAKE : ELECTRO/UNIVERSAL/TIBCON
S&F Fan Motor Capacitor 6 mfd of AC (Window/ Split Type) 1.5/2.0 TR Capacity including Taking out unserviceable Fan Motor Capacitor from ACcomplete all as specified and directed. MAKE : USHA/UNIVERSAL/TIBCON
S&F Condenser coil for Split AC 1.5/2.0 TR capacity including taking down old unserviceable condenser coil complete all as specified and directed.
S&F Condenser coil for Refrigerator 210/310 ltr capacity including taking down old unserviceable condenser coil complete all as specified and directed.
Gas Charging with R-22/R-32/M-22 Gas of AC (Window/Spilt Type) 1.5/2.0/3.0 TR Capacity with required quantity and as suitable for Refrigerant in the Unit including Checking of Leakage in the System, Brazing the Leakage Parts of Oil Gas Tubing as required complete all as specified and directed.
Gas Charging with R-134A/R-410A/R-407C/R-404A Gas of AC (Window/Spilt Type) 1.5/2.0/3.0 TR Capacity with required quantity and as suitable for Refrigerant in the Unit including Checking of Leakage in the System, Brazing the Leakage Parts of Oil Gas Tubing as required, complete all as specified and directed.
Taking down and shifting to other location AC split type/window (1.5TR, 2.0TR, 3.0TR) capacity and Re-installation/ re-commissioning with one inner unit, one outer unit after minor servicing including making connection with copper tubes from inner unit to outer unit including filling of refrigerant gas and connecting electrically and testing, complete all as specified and directed.
S&F in repair Sheet Metal Enclosures with Plug Top and MCBs Single Pole Enclosure with a Two Pin and Earth Plug and Socket complete with a MCB Single Pole, 6-32 Amp Capacity and Connecting Electrically complete all as specified and directed.
S&F Metal Clad Plug & Socket type 'MP' & 'MS' three pin 20Amp, 250V ,
S&F Copper capillary tube 5/8" as suitable size for repairing window/split type AC including necessary gas welding complete all as specifiesd and directed. (Each coil of 15 RM)
S&F Copper capillary tube 1/4" as suitable size for repairing window/split type AC including necessary gas welding complete all as specified and directed.(Each coil of 15 RM)
All as per item No. 21 above but capacity 210/315 ltr.
S&F Ice Cooling Chamber (as Approved) for Refrigerator 210/315 LITRE Capacity including Taking down unserviceable Ice Cooling Chamber from Refrigerator, complete all as specified and directed.
S&F Starting Relay (OPEN TYPE/BOX TYPE) for Refrigerator of any description including Taking down Unserviceable Starting Relay from Refrigerator, complete all as specified and directed.
S&F Bib tap Cast copper alloy 15 mm bore chromium plated Push type complete all as specified and directed.
S&F PVC Connection with brass unions at both ends with brass nuts, suitable for fixing to 15 mm bore GI Pipe of length 600mm, complete all as specified and directed.
S&F PVC drain out pipe 25 mm bore as per existing by providing necessary GI Clamps nuts bolts etc complete all as specified and directed.
M&L for replacement of base plate of water cooler of any capacity, made out of 2 mm thick MS sheet and painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparation of External old steel surfaces of Water Cooler 40/80 LITRE Capacity, removing existing Paint and applying one Coat Synthetic Enamel Paint (Colour Shade as approved ) with Spray painting and Writing MES No, etc complete all as specified and directed.
M&L for Rewinding Fan Motor of existing Water Cooler 40/80 and 120/150 LITRE Capacity with suitable size Copper Wire including Taking out Unserviceable copper winding from Fan Motor of AC, complete all as specified and directed.
S&F Starting Relay for Water Cooler 40/80/120/150 LITRE Capacity including Taking out Unserviceable Starting Relay from Water Cooler, complete all as specified and directed.
M&L for Overhauling of Voltage Stabilizer of 1.0 KVA, 2.0 KVA/3.0 KVA & 5 KVA Capacity of any make including replacement of defective Relays, Capacitors, Switches, Voltmeters and Testing, complete all as specified and directed.
M&L for Painting of External old outdoor unit shed of split AC'S 1.5/2.0/3.0 TR capacity and removing existing Paint and applying two Coat of Synthetic enamel Paint (Colour Shade as approved ) after preparation of surfaces of AI and PGI sheet complete all as specified and directed.
M&L for repairing De-humidifire, Servicing, cleaning, including checking serviceability at the site and reinstalling at the same place complete all as specified and directed.
M&L for repairing of casset type AC'S after disconnecting from electric supply, opening suction & dicharge pipe from outer unit , removing/ scratch dust with iron brush,cleaning condessor unit,compressor,cooling coil/cleaning of fan blade/ cleaning of filter of inner unit etc, and reinstalling at the same place including Re-filling of refregerent Gas of approved make, complete all as specified and directed.
M&L for insullation to copper tubing of size 1/4"/1/2" as per sample approved complete all as specified and directed.(Each coil of 10 RM)
S&F Flexible pipe of size 20 mm dia complete all as specified and directed.
S&F Flexible PVC cable 3 core, 6 sqmm PVC insulated copper multi-stranded FRLS conductor, drawn through PVC casing caping/ PVC conduit with all accessories as required, complete all as specified and directed.
Taking down wall mounted Geyser of Capacity 25/35/50 ltrs by disconnecting electric supply and water connections including the defective spares and refixing after repair/maint work and testing all as specified and directed. Note : The spares required shall be measured and paid separately under relevant item here-in-after
Taking down and opening the Geyser, Descaling of silt deposited /Cleaning of inner tank of geyser 25 to 35 Ltrs capacity including washing with clean water, checking the spare parts, re-assembling and testing complete all as specified and directed.
All as per item S No 42 here in before but of capacity 50 Ltrs capacity.
M&L for Repairs to inner copper/Steel tank of geyser 50/35/25 Ltrs capacity for leaks by pressure test, including gas welding and making the same leak proof, testing complete all as specified and directed.
Supply only the following spares for Geyser of 25/35/50 Ltrs capacity as per the make of the Geyser Make: Venus/Recold/Ramson/Orison/Bajaj/Ditz
Apparatus plate
Bimetal Thermostat
Auto cut thermostat
Heating element screw/push/triangular type any shape for 1.5 KW capacity
Heating element 2.0 Kilo watts with round/triangle base, push and clamp fixing type
Indicating lamp of any shape/size as per site requirement
Glass wool for insulating of tank
Steel water tank suitable for 25 Ltrs capacity
Copper water tank suitable for 35 Ltrs capacity
Copper water tank suitable for 50 Ltrs capacity
Air pressure release safety valve 15 mm dia
S&F in Replacement of Non-return valve made out of brass vertical type 15 mm dia ISI marked complete all as specified and directed
S&F in replacement of bottom and top cover suitable for existing 50 lit capacity geyser made out of 22 gauge MS sheet as per sample approved duly painted with white synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
All as per serial item No 47 above but for 25 lit capacity of geyser
S&F in replacement of GI union, 15 mm dia medium grade complete all as specified and directed
S&F in replacement of GI nipple, 15 mm dia , 50 mm long medium grade complete all as specified and directed.
S&F in replacement of GI elbow 15 mm dia medium grade complete all as specified and directed
S&F in replaceent of GI socket 15 mm dia, medium grade complete all as specified and directed
M&L for Prepration of outer body surface of Geysers and painting one coat of synthetic enamel paint by spray painting and writing MES No on geyser in block letter not less than 5 mm wide and 25 mm high with black paint for 25 lit capacity of geysers complete all as specified and directed
All as per serial item No 53 above but for 50 Lit capacity Geysers.
S&F in repairs Apparatus plate assembly by means of welding/brazing as required to stop leakage etc for 25/50 lit capacity geyseres of existing make at site and testing complete all as specified and directed
S&F in repair Stop cock cast copper of 15mm bore, chromium plated high pressure with crutch handle including fitting/fixtures complete all as specified and directed.
S&F in repair MS nut bolts 4 Nos, 10 mm dia 150 mm long grouting to brick wall providing PCC (1:2:4) type B-1 for fixing of geyser and making good to disturbed surfaces complete all as specified and directed.
S&F in repair MCB single pole 230 volts 06-32 Amps complete all as specified and directed.
S&F PVC insulated 3 core multistranded copper conductor cable of size 2.5 Sqmm maintaining color code (Red) for Phase, Black for Neutral and green for earth conductor) including taking down the old U/S cable all as specified and directed Make: Plaza/Finolex/Kinjal
S&F Galvanized iron pipe medium grade 15mm bore with all fittings/ fixtures like Tee, Elbow, Bend, union socket etc fixed to wall/ceiling/floor with clamps including taking down the old U/s pipe all as specified and directed Make: Tata/Jindal
S&F sheet metal enclosure with three pin socket and top with one MCB double pole 20 Amps 240 Volts, 50Hz complete all as specified and directed, Make: Havells/Legrand.
S&F Plug Top of 16 Amps suitable for the geyser complete all as speciified and direcetd
S&F in repair Bib tap cast copper alloy of 15 mm bore with crutch handle complete all as specified and directed.
Taking down and shifting to other location Geyser of 25 Litrs capacity and fixing with nuts bolts and washers after grouting in PCC 1:2:4 complete all as specified and directed.
Taking down and shifting to other location Geyser of 50 Litrs capacity and fixing with nuts bolts and washers after grouting in PCC 1:2:4 complete all as specified and directed.
M&L for Sub main wiring 2 x 2.5 sqmm FR PVC insulated copper conductor ,single core cable in PVC casing caping alongwith PVC copper earth wire 1x2.5 Sqmm complete all as specified and directed.
S&F Stainless steel flexible connection pipe for hot /cold water 15mm bore size with PTMT nuts of length 450 mm complete all as specified and directed Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
M/S BARUA REFRIGERATION WORKS
Bidder Name
M/S DHAR AND DHAR
M/S BARUA REFRIGERATION WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .