Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC 42 43A VIDYA SAGAR SARANI PALLY BARISHA KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹44.5 L+₹81,900 (1.88%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹46.3 L+₹2.7 L (6.10%)Rejected-Finance 8 28 BIJOYGARH P O JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹47.0 L+₹3.4 L (7.68%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹47.2 L+₹3.6 L (8.19%)Rejected-Finance 107 1A TOLLYGAUNG ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹42.0 L
EMD Value
₹83,960
Closing Date
18 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR / MAINT OF GEYSERS WITH ALLIED WORKS SERVICES FOR INSIDE AND OUTSIDE FORT WILLIAM UNDER GE FW KOLKATA
2021_MES_483090_1
8796/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (FW) Kolkata
Ref tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (FW) Kolkata
₹83,960
Yes
21 Dec 2021
21 Oct 2021
19 Nov 2021
21 Oct 2021
18 Nov 2021
4 Nov 2021
60 days
Amount
Taking down geysers any type and capacity (25/50 ltrs) from the existing position in wall and removing to stores for repairs, cleaning and re-fixing the same in original position after repairing including electric and water connection, testing etc complete all as directed by Engineer-in-Charge Notes : (i) Parts/accessories for geysers to be replaced shall be measured and paid separately under relevent items. (ii) Parts/accessories replaced against each geyser shall be recorded in tabular form in the MB. (iii) MES No. of geysers repaired shall be recorded in MB.
S&F in repair Copper heating element tubular/spiral steel type element 1500 Watt (ISI Marked) suitable for 25 litres capacity as per sample after removing the existing defective element complete all as directed by Engineer-in-Charge.
S&F in repair Copper heating element tubular/spiral steel type element 2000 Watt (ISI Marked) suitable for 25 litres capacity as per sample after removing the existing defective element complete all as directed by Engineer-in-Charge.
S&F in repair Porcelain heating element 1500 Watt (ISI Marked) suitable for 25 litres capacity as per sample after removing the existing defective element complete all as directed by Engineer-in-Charge.
S&F in repair Porcelain heating element 2000 Watt (ISI Marked) suitable for 25 litres capacity as per sample after removing the existing defective element complete all as directed by Engineer-in-Charge.
S&F in repair thermostat switch ISI marked for geysers of 25-50 litres capacity of micro gap steam type thermostat SEA and make as per sample approved by Engineer-in-charge, including testing complete.
S&F in repair thermostat switch ISI marked for geysers of 25-50 litres capacity of micro gap steam type thermostat TSE and make as per sample approved by Engineer-in-charge, including testing complete.
S&F in repair thermal cut switch ISI marked for geysers of 25-50 ltrs capcity, make as per sample approved by Engineer-in-charge, including testing complete.
S&F in repair thermostat auto cut off switch ISI marked for geysers of 25-50 ltrs capcity, make as per sample approved by Engineer-in-charge, including testing complete.
S&F in repair brass aperture plate complete with pluger pipe, bolts, nuts, and rubber ring complete and all connected components for 25 ltrs capacity geysers including testing complete all as per sample directed by Engineer-in-Charge.
S&F in repair split plate of 22 SWG MS sheet white stove enamelled suitable for bottom cover of 25 ltrs capacity geysers including testing complete all as per sample specified and directed by Engineer-in-Charge.
S&F in repair high density polythene pipe heavy duty confirming to IS 3075, 15mm dia, 600mm long, including brass coupling at each end (weighing not less than 40gms each) one end secured to inlet/outlet of geysers and other end to stop cock all complete with connection complete all as directed by Engineer-in-Charge.
Supply and fix in repair 20 Amps Metal clad socket 3 pin (2P+E), complete all as directed (Make : L&T, Cat No: MPS220S / HPL, Cat No: MHP2S20 / C&S, Cat No: CSDBSSPN020 or equivalent model in ABB / LEGRAND / HAVELLS / INDO ASIAN / HAGER / BCH / SCHNEIDER)
Supply and fix in repair 20 Amp Metal clad plug 3 pin (2P+E), complete all as directed Make : L&T, Cat No: MPS220P / HPL, Cat No: MHP2P20 / C&S, Cat No: CSDBPSPN020 or equivalent model in ABB / LEGRAND / HAVELLS / INDO ASIAN / HAGER / BCH / SCHNEIDER)
S&F of rubber/PVC gasket to ensure water tightness of 25/50 Ltr geyser suitable as per sample complete
Supply & Fixing in repairs Air release valve/dead weight Valve ISI mark suitable for 25/50 Ltr cap geyser specified and as direted by Engr-In-Charge.
Supply & Fixing in repairs Non return Valve brass of 15 mm bore after dismantling old unserviceable NRV of any size all as specified and as direted by Engr-In-Charge.
S&F glass wool (spl quality) at thermal insulation after removing the old glass wool in between the inner container and outer casing complete all as directed by Engineer-in-Charge.
S&F pilot lamps round neon indicator suitable for 25 ltrs capacity geyser fitted on the unit including necessary electric connection, testing complete including taking out old defective indicator complete all as specified and as directed.
S&F in repair stainless steel (SS 304) pipes for geyers, 600 mm long, 15mm dia with brass coupling and union at both ends & washers, heavy duty suitable for fixing on 15 mm dia GI pipe secured to inlet/outlet of geysers and other end to stop cock complete with all connections complete all as specified an directed.
Scraping, cleaning/removing deposited scales, correcting cavities as required for copper vessel outside surface, MS outer shell with top and bottom cover both surface shall be painted with two coat of synthetic enamel paint on outer surface of shell, top and bottom cover shall be painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and one coat of of red oxide to copper vessel outer surfaces and inner surface of outer shall geyser of any size 25/50 ltrs capacity and numbering/marking with different paint complete all as directed by Engineer-in-Charge.
Repairing leaked portion of inner tank of geyser of any type/capacity by mean of spot welding with slider/brass spot brazing and testing complete (Nos of spot welding not exceeding 5) complete all as directed by Engineer-in-Charge.
S&F mild steel bolts and nuts and washer 15mm dia 75mm to 100mm long with cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) including taking out old fixing bolt (set of four) from walls complete all as specified and as directed by Engineer-in-Charge.
S&F Mild steel clamp of flat iron of size (25X6mm ) made to shape 100mm long welded with outer casing of geyser to walls complete all as directed by Engineer-in-Charge.
S&F in repair copper inner tank for hard and soft water pressure upto 100PSI (7.00Kg/Cm2) and normal working pressure is 30 PSI(2.11Kg/Cm2) for 25 litres capacity geyser after removing the existing defective tank complete all as directed. (Make : Bajaj/Venus/Crompton/Racold/Havells or equivalent as approved by Accepting officer )
S&F in repair stainless steel inner tank for hard and soft water pressure upto 100PSI (7.00Kg/Cm2) and normal working pressure is 30 PSI (2.11Kg/Cm2) for 25 ltrs capacity geyser after removing the existing defective tank complete all as directed by Engineer-in-Charge. (Make : Bajaj/Venus/Crompton/Racold/Havells or equivalent as approved by Accepting Officer )
S&F in repair mild steel outer cover 22 SWG for 25 ltrs capacity any dia of geyser including bottom and top cover with MS clamp, outer ring and split pin including two coats of paint over one coat of red oxide primer including dismantling the unserviceable cover as per direction by the Engineer-in-Charge.
S&F in repair PVC insulated and PVC sheathed 0.75 sqmm 3 core flexible copper cable of size 24/0.20, 1100 volts complete including taking down old flexible unserviceable wire complete all as directed by Engineer-in-Charge
S&F metal clad single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 'C' Curve, 10 KA including all accesories complete. (MAKE OF ENCLOSURE : LEGRAND, Cat No. 507814 / L&T, Cat No. DBMPS220SD / SCHNEIDER, Cat No. A9HMS220/C&S, Cat No: CSDBPSSPN020 / C&S, Cat No: CSDBPSSPN020 / HPL, Cat No: MDBSPMT20 / BCH, Cat No: BCHPSDBSPN20 / HAVELLS, Cat No: DHDPUSN020/DHDPUDP020 or Equivalent Model in ABB / INDO ASIAN / HAGER) (NOTE : Enclosure & MCB shall be same manufacturer)
Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc. complete all as specified and as directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
M&L for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/scoket outlet etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one 5 amps switch socket combination on independent board complete all as specified and directed.
All as per item No. 32 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 26 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box).
M&L for concealed type point wiring with 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/socket outlet etc and including 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board complete all as specified and directed. (NOTES: - Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
-ditto- but in existing PVC conduit (NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit)
S & F new Switch piano, flush type, one way. 5/6 Amps, single pole, 240 volts complete all as specified and directed.
S & F new socket outlet, 2 in 1, 3 pin, flush type (non-shuttered), 5/6 Amps, 240 volts complete all as specified and directed.
S&F new switch socket combination outlet, 3 pin, flush type (non-shuttered), 5/6 Amps, 240 volts complete all as specified and directed.
S & F new switch socket combination outlet, flush type (non-shuttered), 6-in-1, 3 pin, 6/16 Amps, 240 volts complete all as specified and directed.
S&F in repair Chromium plated brass Angular stop cock concealed type incl concealed body, fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : Essco, Cat No: DLX-526 / PRAYAG, Cat No: PR-144 / SOMANY, Model: ETHER / JAINKO, Cat No: AVJ-1)
S&F Plug Top, 3 pin, 15/16 Amps, AC 230 Volts complete all as specified and directed
S&F Plug Top, 3 pin, 5/6 Amp, AC 230 Volts complete all as specified and directed
M&L in repair for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and incl PVC casing-caping of suitable size, surface type including taking down existing wiring complete all as specified and directed. (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
S&F in repair stop valve cast copper alloy, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or union for pipe 15mm bore, (ISI marked) complete all as specified and directed.
S&F, 15 mm bore fancy type stop valves, cast copper alloy, chromium plated (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and, complete all as specified and directed. (MAKE : ESSCO, Cat No: DLX-514B / PRAYAG, Cat No : PIS-18 / SOMANY, Model: ETHER / JAINKO, Cat No: CSV-1)
S&F TPN DB, IP 43 protection, double door (premium quality), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T, Cat No. DBTPN004DD / LEGRAND, Cat No: 507670 / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4 / PANASONIC, Cat No: BQS 304H / HAGER, Cat No: VYT04DH)
All as per Item No. 57 above 4 Way (8+12) TPN DB (normal quality) complete all as specified and directed. (MAKE : C&S, Cat No: CSDBTPNHPDD04 /BCH, Cat No: BCHHTPNDD04W / INDO ASIAN, Cat No: 811841 / HAVELLS, Cat No: DHDPTHODRW04 / HPL, Cat No: MDBTDD04)
S&F SPN DB, IP 43 protection, double door (Premium Quality), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN004DD / LEGRAND, Cat No: 507610 / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04 / HAGER, Cat No: VYS04D)
All as per Item No. 59 above 4 Way SPN DB (normal quality) complete all as specified and directed. (MAKE : C&S, Cat No; CSDBSPNPDD04 / BCH, Cat No: BCHSPNDD04W / HPL, Cat No: MDBDD04 / HAVELLS, Cat No: DHDPSHODRW04 / INDO ASIAN, Cat No: 811824)
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs (Premium Quality), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN008DD / LEGRAND, Cat No: 507611 /ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08 / HAGER, Cat No: VYS08D)
All as per Item No. 61 above 8 Way SPN DB (normal quality) complete all as specified and directed. (MAKE : C&S, Cat No: CSDBSPNPDD08 / BCH, Cat No: BCHSPNDD08W / HPL, Cat No: MDBDD08 / HAVELLS, Cat No: DHDPSHODRW08 / INDO ASIAN, Cat No: 811807)
NOTE FOR ITEM NO. 48 to 53 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured and paid seperately. (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
S&F MCB (premium quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (normal quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN)
S&F MCB (premium quality), 'C' series, SPN, 40 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (normal quality), 'C' series, SPN, 40 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (normal quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN)
MS AP CONSTRUTION AND CO
DEB AND COMPANY
KWALITY CONSTRUCTION
ARJUN DAS VALECHA
SINHA ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .