Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC 35 DHARSA MAHITAL KHAN S BYE LANE JIGACHA MUKHERJEE PARA HOWRAH PIN 711112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | L1 | Accepted-AOC The work has been done. | |
| 2 | L2₹38.5 L+₹7.1 L (22.7%)Rejected-Finance CHATAPADMAPUR BATTALA RAMNAGAR CONTAI EAST MEDINIPUR PIN 721433 WEST BENGAL | CONTAI | EAST MEDINIPUR | WEST BENGAL | 721433 | L2 | Rejected-Finance This bidder is not L1 | |
| 3 | L3₹38.5 L+₹7.1 L (22.8%)Rejected-Finance PASCHIM KHILKAPUR G P BARASAT BLOCK 1 | PASCHIM BARDHAMAN | WEST BENGAL | 713148 | L3 | Rejected-Finance This bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
21 Feb 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE
OFFICE OF THE EXECUTIVE ENGINEER JHARGRAM ELECTRICAL DIVISION, P.W.Dte. Panch Matha More, PWD Building, Opposite Rabindra Park, Dist. Jhargram, Pin- 721507
Illumination of Deer Park with LED lamps Road lightning with allied Electrical Works of Jungle Mahal Zoological Park, in the district of Jhargram.
2025_WBPWD_810687_1
WBPWD/EE/JED/eNIQ51/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Jhargram
Please refer Tender documents.
3 documents required · 3 mandatory
₹80,000
13 May 2025
7 Feb 2025
24 Feb 2025
7 Feb 2025
21 Feb 2025
7 Feb 2025
Amount
Supply & delivery of 8.0 Mtr Hot Dip Galvanized (86-65 micron dry film thickness) Octagonal Pole, as per BSEN 10025; ASTM A572; IS 5986: IS 4759/2629, ASTM A123 and BSEN IS 1461 standard. The pole should be 8.0 Mtr long, bottom dia-175 mm, top dia-70 mm, thickness-4mm, continuously tapered and shall have octagonal cross section with pole cap at top, necessary cleat attachment/hanger for arm brackets. Base-plate having dimension 275x275x16 mm (minimum) and 4 nos 'J'-Type foundation bolt with double nut and plate washer, bolt dia 24mm , PCD- 300 mm ,bolt length- 750 mm/500 mm, Projected bolt length - 125 mm( these dimension are subjected to tolerance as per IS-2102 except for bending radius). The pole will consist of a built-in loop-box having one 32A 4-terminal stud type connector, one 250V 5A kit-kat fuse unit, one NL on porcelain insulator, it permits clear access to equipment like winches, cables, socket, etc and also facilitate easy removal of the winch. The door opening shall be complete with a closefitting, vandal resistance, weatherproof door( to IP-55 of IS:2147), providing with a heavy duty double internal lock with special paddle key. The door opening shall be carefully designed and reinforced with welded steel section , so that the mast section at the base shall be unaffected and undue buckling of the cut portion is prevented. The Pole should be supplied with adequate templates for the purpose of construction of base foundation. The pole should have earthing terminals 02(two) nos at a height of 600 mm from the base plate for connection of earth continuity wires/ conductors.( Bajaj/ Valmont/Orient/Surya
Erection of 8.0 Mtr octagonal GI (Hot Dip Galvanized in single dip) pole 1.6 Km from the store to work-site with foundation of M20 grade concrete for 8.0 Mtr GI Octagonal Pole with all the materials like sand, cement, stone chips, reinforcement steel, binding wire etc as relevant IS Code. by PCC Base foundation having (L-1000mm x W-1000mm x H-100mm) & RCC foundation having dimension (L-600mm x W-600mm x H-1600mm) including neatly cemented finish (3mm thick) partly below and above ground level. There should be multiple alkathene pipes upto 1.2 mtrs of 50 mm dia of adequate length for distribution of incoming & outgoing cables for street light wiring as directed by EIC in the CC foundation of octagonal poles.
Supply & Fixing of Hot Dip Galvanized (86-65 micron dry film thickness) 1.5 Mtr long Sword type Single Arm bracket made of 40NB Pipe with ball and Dome, as directed by EIC.(As per IS 5986: IS 4759/2629, ASTM A123 and BSEN IS 1461 standard.)
Supply and Delivary of Street Light Fittings
Supply of 150 W Street Light Lumen Efficacy >120 , CRI>70, CCT-5700K, IP- 66, Aluminum Dia Cast Housing , Potted driver, 4KV Internal 10 KV external SPD, LM 79 Report shall be provided from manufactures ownNABL Lab, Make : Bajaj model no. ENXT P 180L WH PO TG SD or equivalent model of Phillips/Bajaj/Surya/Orient as per direction of EIC ,Lighting Technology. (5 years of Warranty & Light efficacy will not get depreciated less than equal to 70% of the rated value over the lifetime of the Luminaries)
Supply & Delivery of 4 core 16sqmm of 1.1 KV grade alluminium XLPE Al. armoured LT cable, as directed by EIC. [Make : Havells/Polycab/Finolex/RR Kabel/KEI/Gloster]
a)Supply & Delivery of 4 core 25sqmm of 1.1 KV grade alluminium XLPE Al. armoured LT cable, as directed by EIC.[Make : Havells/Polycab/Finolex/RR Kabel/KEI/Gloster]
Laying only above 4 core 16sqmm cable through existing RCC/Hume/ GI Pipe/open masonry trench, as per GS.[F-1/3(A)]
Laying only above 4 core 16sqmm/25sqmm cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed, as per GS.[F-2-1(a)]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish from 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. [F-3/5(1)]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :[F-4/7(C )]
4 Core 16 Sq.mm
4 Core 25 Sq.mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
4 Core 16 Sq.mm [F-5-8(b)(xii)]
4 Core 25 Sq.mm [F-5-8(b)(xiii)]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm), as per GS. [E-9-C-1(a)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S&F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by ISI-Medium GI pipe, as per GS.[G-1-2(a)]
Excavation of soil for installation of Earth Electrode and filling & ramming, for Soft soil, as per GS.[G-1-1(a)]
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc., as per GS. (for flyover continuous earthing)[G-3-5(c)]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages No. 6 SWG
Proving trained manpower for guarding and traffic management at specific work zone as per direction of EIC
S & Installation of Feeder pillar box of suitable size made with 2 mm MS plate having front & back opening hinged with door handle and double locking arrangement with Godrej lock and keys. There should be proper ventilation spout at the centre of the top side. The pillar box should be erected over suitable brick structure with plaster and neat cement finish and to be painted by two coats of paints over two coats of primer. The pillar box should be provided with following incl. S&F switches, necessary connection etc. as required. 1) S & F 415V, 63A ,TPN Main switch (L&T)---1no. 2) S & F 415V, 100A,4 nos Bar Copper BBC---1no 4) S & F Time switch GIC make type FM quartz----1nos 5) S & F 3-Pole power contractor L & T Make ,(ML-3)-1nos 6) Outgoing 40 A TPN MCB --4 nos 7) Auto/Manual Toggle switch ---1nos 8) Diode type neon Indicator Lamp-3nos 9) Base for fixing three Phase Energy Meter at the back Side.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing materials as required.
50 mm dia
Supplying & Fixing PVC waterproof type looping cable box(SINTEX/As per EIC) size minimum 200x150x100 mm deep comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, two provision of compression type brass cable gland for upto 4- core 16 sqmm PVC/A cable and having lined with rubber gasketted top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole, including S&F 40x6 mm thick, suitable "C" type 4mm thick MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
Supplying and fixing 415V, 63A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(Make-LT/Havells / Standard)
Load Augmentation charges of WBSEDCL
TAPAN ELECTRICS (BID ID -6116924)
MODERN ELECTRIC (BID ID -6114557)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .