Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 CrAdmitted-Finance | ₹7.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹8.1 Cr+₹82.3 L (11.4%)Admitted-Finance | ₹8.1 Cr+₹82.3 L (11.4%) | L2 | Admitted-Finance |
| 3 | L3₹8.1 Cr+₹83.5 L (11.5%)Admitted-Finance | ₹8.1 Cr+₹83.5 L (11.5%) | L3 | Admitted-Finance |
| 4 | L4₹8.2 Cr+₹90.9 L (12.5%)Admitted-Finance | ₹8.2 Cr+₹90.9 L (12.5%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S QAZI MUSHTAQ SON L1 | Ms Abdul Aziz Mir L2 | Ghulam Qadir L3 | SHARAT PURI CONTRACTORS L4 |
|---|---|---|---|---|---|---|---|
| 1.00Approach Road | |||||||
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator) over areas (Exceeding 30cm in depth, 1.5mtr in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.50 m, disposed earth to be levelled and neatly dressed in all kinds of soil 70% ordinary rock 30% for approach road. | 1,100 | Cum | - | - | - | - |
| 3.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. | 1,564 | Cum | - | - | - | - |
| 4.00Building Part | |||||||
| 5.00 | Earth work in excavation by mechanical means (Hydraulic excavator) over areas (Exceeding 30cm in depth, 1.5mtr in width as well as 10sqm on plan)
including disposal of excavated earth, lead upto 50m and lift upto 1.50 m, disposed earth to be levelled and neatly dressed in all kinds of soil 80% ordinary rock 20% for platform cutting. | 3,000 | Cum | - | - | - | - |
| 6.00 | Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches, drains, pipes and cables etc. (not exceeding 1.5mtr in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5mtr including getting out excavated soil and disposal of surplus soil as directed, within a lead of 50 mtr. in all kinds of soil 80% ordinary rock 20%. | 1,500 | Cum | - | - | - | - |
| 7.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level 1:5:10 (1 cement: 5 coarse sand :10 graded stone aggregate 40mm nominal size) Crushed | 160 | Cum | - | - | - | - |
| 8.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level 1:5:10 (1 cement: 5 coarse sand :10 graded brick aggregate 40mm nominal size upto floor V level) | 210 | Cum | - | - | - | - |
| 9.00 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring and shuttering- All work upto plinth level 1:1.5:3(1 cement:1. 5 coarse sand :3 graded stone aggregate 20mm nominal size) | 430 | Cum | - | - | - | - |
| 10.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts ans sturts, etc. upto floor five level excluding cost of Centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size) | 550 | Cum | - | - | - | - |
Tender Value
₹8.3 Cr
EMD Value
₹16.6 L
Closing Date
3 Mar 2020, 4:00 pmClosed
Er. Arshad Mir
Office of the Deputy General Manager, JKPCC Ltd., Unit 8th Rajouri.
Construction of New Degree College at Darhal Rajouri Phase-1st
2020_PWDJK_92003_1
e-NIT No. 26/Rajouri of 2019-20 Dt. 04-02-2020
Open Tender
Civil Works
Item Rate
540 days
RAJOURI
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
Yes
Financial Controller, JKPCC Ltd.
₹16.6 L
Yes
O/o Managing Director, JKPCC Ltd., Jammu
23 Jul 2020
5 Feb 2020
4 Mar 2020
5 Feb 2020
3 Mar 2020
10 Feb 2020
10 Feb 2020
Amount
Approach Road
Earth work in excavation by mechanical means (Hydraulic excavator) over areas (Exceeding 30cm in depth, 1.5mtr in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.50 m, disposed earth to be levelled and neatly dressed in all kinds of soil 70% ordinary rock 30% for approach road.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
Building Part
Earth work in excavation by mechanical means (Hydraulic excavator) over areas (Exceeding 30cm in depth, 1.5mtr in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.50 m, disposed earth to be levelled and neatly dressed in all kinds of soil 80% ordinary rock 20% for platform cutting.
Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches, drains, pipes and cables etc. (not exceeding 1.5mtr in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5mtr including getting out excavated soil and disposal of surplus soil as directed, within a lead of 50 mtr. in all kinds of soil 80% ordinary rock 20%.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level 1:5:10 (1 cement: 5 coarse sand :10 graded stone aggregate 40mm nominal size) Crushed
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level 1:5:10 (1 cement: 5 coarse sand :10 graded brick aggregate 40mm nominal size upto floor V level)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring and shuttering- All work upto plinth level 1:1.5:3(1 cement:1. 5 coarse sand :3 graded stone aggregate 20mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts ans sturts, etc. upto floor five level excluding cost of Centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size)
Providing and laying Reinforced Cement Concrete 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) in suspended floors, balconies, landings and staircase having upto 15° slope. excluding cost of centering and shuttering , all work upto floor V level
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level 1:3:6 (1 cement: 3coarse sand :6 graded stone aggregate 20mm nominal size) crushed
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. TMT bars
Centring and shuttermg including strutting, propping etc. and removal of form for· Foundations: footings, bases of columns etc. for mass concrete.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders,bressumers and centilevers.
Edges of slabs and breaks in floors and walls. Under 20 cm wide
Columns, Pillars, Piers, Abutments, Posts and Struts
Walls any thickness including attached pilasters, buttresses plinth and
Weather shade. Chajjas, corbels etc., including edges.
Stairs, (excluding landings) except spiralstaircases.
Providing and laying damped proof course 40 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand :4 graded stone aggregate 12.5mm nominal size) crushed
Brick work with common burnt clay F.P.S.(non-modualar)bricks of class designation 75 in foundation and plinth in Cement mortar 1 :6 ( 1 cement : 6 coarse sand)
Extra for brick work in superstructure above plinth level upto floor V level. (By manual means)
Half brick masonry with bricks of class designation 75 in foundations and plinth in Cement mortar 1 :4 ( 1 cement : 4 coarse sand)
Extra for half Brick masonry in superstructure above plinth level upto floor V level.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class teak wood
Providing and fixing lSI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including lSI marked M.S. pressed bright finished butt hinges with necessary screws of required size
12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) with making of groove between brick work and RCC
15mm Cement plaster of mix: 1 : 6( 1 cement : 6 fine sand) with making of groove between brick work and RCC
20 mm Cement plaster of mix: 1 : 4( 1 cement : 4 coarse sand) with making of groove between brick work and RCC
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 60x60cm
Providing and fixing Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 13755 of NITCO, ORIENT, SOMANY, KAJARIA or equivalent make in colour such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick bed of Cement Mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing antiskid floor tiles for ramp 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 13755 of NITCO, ORIENT, SOMANY, KAJARIA or equivalent make in colour such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick bed of Cement Mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing 1st quality ceramic glazed tiles conforming to IS :·13753 of minimum thickness 5 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA, or equivalent make in all colour, shades except begundy, bottle green, black of any size as approved by Eningeering in Charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 ( 1 cement: 3 coarse sand) and jointing wtih grey cement slurry@ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing gang saw cut mirror polished (pre moulded and pre Polished), machine cut for kitchen platform, vanity counters window sills facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels 16mm thick
Providing and fixing gang saw cut mirror polished (pre moulded and pre Polished), machine cut for stair steps and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels 16mm thick
Extra for providing opening of required size and shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble I stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
Extra for providing edge moulding to 18 mm thick marble stone counters, Vanities etc. over item no. 8.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge Granite work
Strctural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G. I limpet washers or with G. I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whereever required. 0.63mm thick with zinc coating not less than 27 5gm/m2
Providing and fixing of anchor board bolts 450 mm long with nuts for holding trusses,
Providing and fixing plained eaves boarding. 300x40 mm (nominal size)
Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G. I. limpet and bitumen washers complete. 0.63mm thick with zinc coating not less than 275gm/m2
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanised with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastner 12.5 mm diax40mm long with 6 mm dia bolts, othP.r flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G. I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick buttom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.l.intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G. I. wire at every junction, including fixing perimeter channels 0.5mm thick 7mm high having flanges of20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at450 mm centre to centre, with 25mm long drive-all screws@ 230 mm interval ,including fixing of gypsum board to celing section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers' specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with: 2.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-Part 1
Providing and laying water proofing treatment to vertical and horizontal surface of depressed portions of W.C., kitchen and the like consisting of : (I) 1st course of applying cement slurry @ 4.4kg/sqm mixed with water proofing compound conforming to IS: 2645 in recommended proportions including rounding of Junctions of vertical and horizontal surface. (II) lind course of 20mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions including rounding of Junctionsof vertical and horizontal surface. (Ill) Ill course of applying blown or/ residual bitumen applied hot at 1.7 kg. per sqm of area. (IV) IVth course of 400 micron thick PVC sheet. (Overlaps ·-1 at joints of PVC sheet should be 1 OOmm wide and pasted to each other with bitumen @ 1. 7 kg/sqm.
Providing and laying integral cement based water proofing treatment including prepration of surfaces as required for treatment of roofs, balconies, terracies etc consisting of following operations. a) applying a slurry coat of neat cement using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement: 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 andapproved by Engineer-in-charge. d) finishing the surface with 20mm thick jointless cement mortar of mix 1 :4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved byEngineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finially finishing the surface with trowel with neat cement slurrv and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer-in-charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design : In 75x75 mm deep chase
Making khurras 45x45 em with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outletcomplete.
Providing and fixing 1 mm thick M.S. steel door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer Using M.S. angles 40x40x6mm for diagonal braces
Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggreagate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. Crushed.
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface Water thinable Cement primer (Interior)
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Conpound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour Two coats
Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface Water thinable Cement primer (Exterior)
Finishing walls with acrylic smooth exterior paint of required shade on New work (two or more coats applied @ 1.67 litre/1 0 sqm over and including base Coat of water proofing cement paint applied @ 2.20kg/1 Osqm)
Applying priming coat: with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade on wood work. Two or more coats on new work
Painting with ready mixed synthetic enamel paint of approved brand and manufacture in all shades to give an even shade New steel work (two or more coats)
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and em beddings in cement concrete block 30x10x15 cm 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size )
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc.including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete,i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standardtubular sections/appropriate Z.sections and othersections of approved make conforming to IS : 733 and IS : 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber I neoprene .. gasket felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing I panelling, C.P. brass I stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- Charge (glazing, panelling and dash fasteners to be paid for separatelyPowder coated aluminium (minimum thickness kg 453.15 of powder coated 50 microns)
Providing and fixing 12mm thick prelaminated particle boardflat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-l type-11) in panelling fixed in aluminium doors, windows shutters and partition frames with C. P. brass I stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber I neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item.) With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg I sqm)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo em,possed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot" and single piece M.S. sheet outer box with slide plate etc. complet~ as per the direction of Engineer-in- Charge With Stainless Steel cover plate minimum 1.25 mm thickness
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 minimum anodic coating of Grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing windows frame with C.P. brass/stainless steel screws@ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (onlyweight of grill to be measured for payment)
Providing and fixing Galavanised wire mesh of average width of aperture 1.4 mm and nominal dia. of wire 0.63 mm in in aluminium door, window, ventilator shutters etc. with EPDM rubber I neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item.)
Providing and fixing lSI marked aluminium butt hinges lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 75x63x3.2 mm
Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 150x10 mm
Providing and fixing aluminium handles lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete 125 mm
Providing & fixing aluminium sliding door Bolts ISI marked anodized (annodic coating not less than grade AC 10 as per IS: 1368) transparent or dyed to required colour or shade with necessary screw etc. 300x16mm
Providing & fixing aluminium tower Bolts ISI marked anodized (annodic coating not less than grade AC 10 as per IS: 1368) transparent or dyed to required colour or shade with necessary screw etc. 300x10mm
Providing & fixing aluminium handles ISI marked anodized (annodic coating not less than grade AC 10 as per IS: 1368) transparent or dyed to required colour or shade with necessary screw etc. 450 mm
Carriage of material including loading and unloading and stacking at site complete Sand for average distance of 135 KM by MT
Stone aggregate Crushed 20mm and 40mm nominal size for average distance of 20 KM by MT
Bricks from average distance of 135 KM by MT
Plumbing/Sanitary
Providing and fixing water closet squatting pan ( Indiantype W.C. pan) with 100 mm sand cast Iron P or Strap,10 litre low level P.V. C. flushing cistern including flushpipe (of approved make) "manually contro(led device(handle lever) conforming to IS:7231, with all fittings andfixtures complete, including cutting and making goodthe walls and floors wherever required Orissa pattern white vitreous china W.C. pan of size 580x440 mm with integral type foot rests.
Providing and fixing white vitreous china pedestal type water closet (European type W.C . .pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures, complete including cutting and making good the walls and floors wherever requied W.C. pan with lSI marked white solid plastic seat and lid.
Providing and fixing wash basin with C. I./M.S. brackets,15mm C.P. brass pillar taps, 32 mm C.P. brass waste ofstandard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China wash basin size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated levers.
Providing & fixing of 32mm C.P Brass Waste Coupling for wash basin and sink, of approved quality.
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fitting complete. Flexible pipe 32 mm dia
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with C. I./M.S. brackets standard size of G. I. flush pipe and C.P. brass spreaders with brass unions and G. I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required Range of two urinal basins with 5 litre P.V.C white automatic flushing cistern of approved quality
Providing and fixing Salem Stainless Steel A lSI 304 (18/8) kitchen sink as per I.S. 13983 with C.l. brackets and stainless steel plug 40 mm including painting of fitting sand brackets, cutting and making good the walls wherever required 510x1040mm bowl depth 250mm
Providing and fixing 100 mm CP grating for gully, floor or Nahani trap.
Providing and fixing mirror of superior glass( of approved quality) and of required shape and size with plastic . moulded frame of approved make and shade with 6 mm thick hard Rectangular shape 453x357 mm
Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C. P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete
Providing and fixing toilet paper holder C.P. brass
Providing and fixing PVC pipes of following dia working pressure 6kg/cm2 of make Supreme, finolex or equivalent 160 mm dia
110 mm dia
75 mm dia
Providing and fixing PVC bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 160 mm dia working pressure 6kg/cm2 of make Supreme, finolex or equivalent
100 mm dia working pressure 6kg/cm2 of make Supreme, finolex or equivalent
75 mm dia. working pressure 6kg/cm2 of make Supreme, finolex or equivalent
Providing and fixing PVC plain bend of required degree: 160 mm dia. working pressure 6kg/cm2 of make Supreme, finolex or equivalent
100 mm dia. working pressure 6kg/cm2 of make Supreme, finolex or equivalent
75 mm dia. working pressure 6kg/cm2 of make Supreme, finolex or equivalent
Providing and fixing single plain junction of required degree with PVC acess door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x100mm dia working pressure 6kg/cm2 of make Supreme, finolex or equivalent
75x75x75mm dia working pressure 6kg/cm2
Providing and fixing single unequal junction of required degree with PVC acess door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x100mm dia working pressure 6kg/cm2 of make Supreme, finolex or equivalent
Providing and fixing single unequal plain junction of required degree working pressure 6kg/cm2 of make Supreme, finolex or equivalent
Providing and fixing PVC offsets working pressure 6kg/cm2 of make Supreme, finolex or equivalent 76 mm off sets. With 75 mm dia. Pipe
76 mm off sets. With 100 mm dia. Pipe
152 mm off sets. With 75 mm dia. Pipe
152 mm off sets. With 100 mm dia. Pipe
100mm PVC S&S working pressure 6kg/cm2 of make Supreme, finolex or equivalent
75 mm PVC S&S working pressure 6kg/cm2 of make Supreme, finolex or equivalent
Providing and fixing PVC collar: 100mm working pressure 6kg/cm2 of make Supreme, finolex or equivalent
75mm working pressure 6kg/cm2 of make Supreme, finolex or equivalent
Providing PVC solution joints of diameter 100mm
Providing and fixing trap of self cleaning design with screwed down or hinged grating with or with or without vent arm complete, including cost of cutting and making good the walls and floors: 100mm inlet and 100mm outlet working pressure 6kg/cm2 of make Supreme, finolex or equivalent
100mm inlet and 75mm outlet working pressure 6kg/cm2 of make Supreme, finolex or equivalent
Cutting chases in brick masonry walls for following diameter PVC pipes and making good the same with cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 12.5mm nominal size) 1:4 ( 1 cement: 4 coarse sand) 100mm dia.
75mm dia.
Providing and fixing M.S. stays and clamps for PVC pipes of diameter. 100mm dia.
75mm dia.
Providing and fixing Soap dish (C.P. brass) with bracket
Providing and fixing towel ring (C.P. brass)
Providing and fixing G.l. pipes complete with G.l. fittings and clamps, including cutting and making good the walls etc.: 15 mm dia. nominal bore (medium)
20 mm dia. nominal bore (medium)
25 mm dia. nominal bore (medium)
Providing and fixing G.l. pipes complete with G.l. fittings including trenching and refilling etc. (external work) 25 mm dia. nominal bore
40 mm dia. nominal bore
Making connection of G.l. distribution branch with G.l. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 25 to 40 mm nominal bore
Providing & fixing Brass gate ball valve of approved quality conforming to IS : 8931 of 15mm nominal bore
Providing & fixing Brass gate ball valve of approved quality conforming to IS : 8931 of 20mm nominal bore
Providing & fixing Brass gate ball valve of approved quality conforming to IS : 8931 of 25mm nominal bore
Providing & fixing Brass gate ball valve of approved quality conforming to IS : 8931 of 32mm nominal bore
Providing & fixing Brass gate ball valve of approved quality conforming to IS : 8931 of 40mm nominal bore
Providing & fixing Brass gate ball valve of approved quality conforming to IS : 8931 of 50mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS : 8931 15 mm nominal bore
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms 15 mm nominal bore
Providing and fixing C.P. Jet with connection pipe
Providing and fixing C.P. brass angle valve for basin mixer and gyser points _of approved make conforming to IS : 8931 15 mm nominal bore
Providing and fixing C.P. brass close hole basin mixer centre hole of approved quality and make, weighing not less than 1.970 kg 15 mm nominal bore of standard back type.
Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) R.C.C. top slab with 1 :2:4 mix ( 1 cemE?nt : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finsihed with a floating coat of neat cement complete as per standard design Inside size 90x80 em and 45 em deep including C.l. cover with frame (light duty) 455x61 Omm. internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With F.P.S. bricks with class designation 75 & with Crushed stone aggregate
Providing and fixing G.l. Union in G.l. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
40 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank lSI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid lSI license].
Constructing brick masonry chamber for underground C.l. ...,inspection chamber and bend with 75 class designation bricks in cement mortar 1:5 ( 1 cement: 5 fine sand) C. I. cover with frame (light duty) 455x6.1 0 mm internal dimensions, total weight of cover with fram.. e to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:2:4 mix ( 1 cement : 2coarse sand : 4 stone aggregate 40 mm nominal size),foundatior concrete 1:5:10 (1 cement: 5 fine sand: 10 graded f'tone aggregate 40mn nominal size), inside plaste:;r;g 12 mm thlck with Gernent mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of;neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x600x1 0 mm and 45 cm deep for single pipe line with common burnt clay bricks.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 em in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G. I. pipe etc.
Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement: 3 coarse sand 6 graded stone aggregate 20 mm nominal size) including disposal of malba.
Providing installation and testing of geysor of approved quality and manufacture venus/Bajaj or equilant all complete 50 litres capacity
35 litre capacity
Making soak pit 2.5 m diameter 3.0 metre deep with 45x45 em dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Internal Electrification Work
SUB HEAD-1 WIRING Wiring for switch controlled primary light points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface/concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 6 Amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications( Group C)
Wiring for switch controlled emergency light points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface / concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 6 Amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications and as required
Wiring for ceiling fan points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface / concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 6 Amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box with space for mounting an electronic fan regulator and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications.
Wiring for exhaust fan points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface / concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 3 pin 6 Amp shuttered socket outlet and 6 amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications.
Conduit carrying non-essential wiring shall not have essential or UPS wiring. Wiring for essential and UPS Providing, transportation will have thier own conduit system. No mixing of wiring is allowed.
Providing,transportation & fixing following suitable size modular GI box on surface or in recessas, painting etc.required. 2 Module
4 Module
6 Module
Providing and fixing of following size modular cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
4 Module
6 Module
Providing,transportation and fixing of 6 Amp 3/5 pin modular socket-on the existing modular plate & switch box excluding modular plate as required.
Providing,transportation and fixing of 16 Amp modular switch on the existing modular plate & switch box excluding modular plate as required.
Providing,transportation and fixing of 16 Amp modular socket on the existing modular plate & switch box excluding modular plate as required.
Providing and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Providing and fixing stepped type 2M-electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Providing,transportation and fixing ISI marked medium class PVC conduit on surface/recessed along with accessories including the cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting complete as per specifications as below and as required for sub circuits/ voice/ data/ TV system. 25 mm dia
40 mm dia
Providing,transportation and fixing of RJ-11 modular socket on the existing modular plate & switch box excluding modular plate as required for telephone system
Providing and drawing 2Pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing recessed PVC conduit as required.
Providing,transportation and fixing of the following sheet steel clad wall / recess mounting 10 Pair telephone tag block of IDC type constructed from 16 SWG sheet steel, finished with red oxide coating & two coats of paint, with hinged gasketted door and complete with adequately rated and sized telephone terminal block to receive incoming and outgoing wires.
Providing,transportation and fixing of RJ-45 modular socket on the existing modular plate & switch box excluding modular plate as required for networking system
Providing,transportation fixing, laying, testing and commissioning of 4-pair Cat 6e LAN cable in existing concealed / surface conduits in partition wall, complete as required
Telephone system and computer network will have separate conduit. No mixing of telephone and power wiring is allowed.
SUB HEAD III-SUB MAINS AND CABLES Wiring for circuits/submains with FRLS PVC insulated stranded copper conductor 1100 volt grade wires in surface/concealed conduit and including FR PVC insulated copper wire for earthing and making suitable end connections complete as required and as below. 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
2 X 6 sq. mm + 1 X 6 sq. mm earth wire.
2 X 10 sq. mm + 1 X 10 sq. mm earth wire.
2 X 16 sq. mm + 1 X 16 sq. mm earth wire.
SUB HEAD IV-DISTRIBUTION SYSTEM Providing,transportation, Providing and fixing following way,horizontal type three pole/single pole and neutral,sheet steel, MCB distribution board, 415/240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator). 6 way TPN double door
8 way TPN double door
12 way SPN double door
16 way SPN double door
Non-essential, Emergency and Power will have separate sub main boards. No mixing of wiring is allowed.
Providing and fixing 5 amps to 32 amps rating, 240 volts SP MCB 10kA, "C" curve, miniature circuit breaker suitable in the existing MCB DB complete with connections, testing and commissioning etc.
Providing and fixing following rating, double/four pole, 240/415 volts, DP/TPN MCB 10kA "C" curve in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32 amp
100 amps TPN
Providing and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
Providing and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Providing,transportation , providing and commissioning of following size cable in pipe/ Tray/ clamped to wall with suitable clamps saddles and fixing bolts. 3.5 core 240 Sq mm AL XLPE
3.5 core 120 Sq mm AL XLPE
Laying in ground including the cost digging and back filling with sand and brick protection as required The costs shall include for all cables to be provided with a 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables and route markers for cables in ground. 3.5 core 240 Sq mm AL XLPE
3.5 core 120 Sq mm AL XLPE
Providing,transportation and making end termination of the following size XLPE insulated cables 1100 Volt grade including cost of crimping tinned copper heavy duty lugs, brass compression glands, insulation tape and all requisite material for completion of joints. 3.5 core 240 Sq mm AL XLPE
3.5 core 150 Sq mm AL XLPE
Providing,transportation and fixing of 6in dia heavy PVC pipe complete as required.
Providing,transportation ,providing and fixing of 4in dia heavy PVC pipe complete as required .
Providing,transportation and fixing of 50W LED slim flood light.
Providing,transportation,providing and fixing of fan box
Providing,transportation,providing and fixing of fan plates big size
SUB HEAD V-FIXTURES AND FITTING Supply, transportation and fixing of 1x1 18W surface downlighter with a nominal system lumen output of 2050 lumens and a minimum system efficacy of min100 lm/W complete as required The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 The luminaire shall meet IP20 rating with THD<10%. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance.
Supply, transportation and fixing of 2x2 36W surface downlighter with a nominal system lumen output of 2050 lumens and a minimum system efficacy of 115 lm/W complete as required The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 The luminaire shall meet IP20 rating with THD<10%. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance.
SITC of ISI marked 5star energy saving 1200 mm sweep ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
SITC of exhaust fan 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Sample of all type of light fixtures / fans / exhaust fans / other fittings shall be approved from architect / site engineer & the sample of each approved fixture / fitting shall be kept & maintained at site.
SUB HEAD VI-Cable Tray Providing,transportation fixing and installing 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, inconvenient sections, including bolts & nuts, painting suspenders etc as required.
SUB HEAD VI-EARTHING Providing, transportation & Installation of earth pit comprising of 75 mm Cu pipe filled with crystalline conductive mixture with copper strip of size 40mm x 6mm of length 2 mtrs with eco friendly backfill compound 50 Kgs etc as required conforming to BIS standards having brick masonary chamber with hinged cover. (General Earthing for Each Panel)
(25 x4) mm GI Strip through PVC sleeve (Electrical Earthing) (From Electrical Earthing Pit to Electrical Earthing Busbar)
Providing and fixing of lightning arrestor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85mm dia 3 mm thick copper base plate including holes etc. complete job as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For Horizontal & Vertical run)
Providing,transportation ing and fixing 20 amps, 240 volts, SPN industrial type, socket outlet.
Design, manufacture, supplying fixing in position, testing and commissioning of the following front operated cubicle type, front access, dead back, steel enclosed free standing, dust and vermin proof, switchboard with with hinged and lockable doors complete with interconnections
630 Amps TPN MCCB
250 Amps TPN MCCB
100 Amp DP MCB
125 Amp TPN MCB
63 Amp FP Change over Switch
Cast resin current transformers
Amp & Volt Meter
White phase indicating lamps
Supply and fixing of iron stands for panels
Supply & Installation of earth pit as required
Supply and fixing of GI strip
supply and fixing of spreaders for solid connections of cables with 630Amp MCCB's
supply and fixing of spreaders for solid connections of cables with 250 Amp MCCB's
Ms Abdul Aziz Mir
Ghulam Qadir
SHARAT PURI CONTRACTORS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
SBDE26Darhal.pdf
Tender Documents • 0.52 MB
BOQ_173052.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .