Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC Bidder awarded due
to lowest
bid value | |
| 2 | L2₹19.7 L+₹2.6 L (15.0%)Rejected-Finance | L2 | Rejected-Finance REJECTED
BIDDER
DUE TO
HIGH BID
VALUE | |
| 3 | L3₹20.8 L+₹3.7 L (21.9%)Rejected-Finance | L3 | Rejected-Finance REJECTED
BIDDER
DUE TO
HIGH BID
VALUE | |
| 4 | L4₹21.4 L+₹4.3 L (25.4%)Rejected-Finance | L4 | Rejected-Finance REJECTED
BIDDER
DUE TO
HIGH BID
VALUE | |
| 5 | L5₹22.1 L+₹5.0 L (29.5%)Rejected-Finance | L5 | Rejected-Finance REJECTED
BIDDER
DUE TO
HIGH BID
VALUE |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
30 Jun 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL VASEEM HIROLI
GE 859 EWS, C/O 99 APO, PIN-913859
REPAIR AND PREVENTIVE MAINT OF PUMP SET, STARTER PANELS, EARTHINGS AND OTHER ALLIED WKS FOR WATER SUPPLY INSTALLATION UNDER GE 859 EWS
2022_MES_528008_1
8334/E8
Open Tender
Civil Works
Item Rate
180 days
TENGA VALLEY
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 859 EWS
₹32,000
Yes
27 Jul 2022
2 Jun 2022
1 Jul 2022
2 Jun 2022
30 Jun 2022
16 Jun 2022
60 days
Amount
M&L for complete servicing by expert/auth service engineer once in quarter (three months or interval) including cleaning of engine with karosene or by blower where necessary, prevention of leakage of fuel / oil / water / coolant, tightening of loose nuts and bolts, retensioning of fan belt, descaling of radiator cleaning with cleaning agent, cleaning of fins by applying pressuried air using blower , checking of all electrical connections and testing on full load of Diesel Engine driven Pumping Set 127 BHP Capacity at Gachham Pump House and Birpur Pump House. Note :- (i) Items like Nuts, Bolts, washers, benjo bolts required at site deemed to be included in this unit rate. (ii) Major spares required at site will be measured and paid separately. (iii) Fuel and lubricants required for inspection and testing will be supplied by the Deptt.
S&F Fuel Filter element including 'O' ring for pump set.
S&F Lub Oil Filter element complete suitable for pump set.
S&F Air Filter element suitable for pump set.
S&F Fan Belt suitable for pump set.
Supplying Inhibitor Corrosion suitable for pump set.
Disconnecting/ unscrewing coupling set for RKB 125/150 HP pump set and seperating Pump and Motor/Gen Set, disconnecting all water connections from pump including suction and discharge pipe line and taking out the pump from base frame, transporting to workshop to carry out the necessary repairs and took back after repairs , installing on existing location,making all the connections carefully, commissioning and testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid seperately.
Replacement of Coupling set suitable for RKB 125/ 150 HP Pumping Set.
Replacement of gun metal impeller suitable for RKB 125/ 150 HP Pumping Set.
Replacement of gun metal bush suitable for RKB 125/ 150 HP Pumping Set.
Replacement of Gland Sleeve suitable for RKB 125/ 150 HP Pumping Set.
Replacement of body neck ring gun metal suitable for RKB 125/ 150 HP Pumping Set.
Replacement of Pump shaft stainless steel suitable for RKB 125/ 150 HP Pumping Set.
Replacement of Counter plate stainless steel suitable for RKB 125/ 150 HP Pumping Set.
Replacement of Diffuser Packing suitable for RKB 125/ 150 HP Pumping Set.
Replacement of Key way of Impeller disc suitable for RKB 125/ 150 HP Pumping Set.
Replacement of Key way of diffuser suitable for RKB 125/ 150 HP Pumping Set.
Replacement of Balancing disc suitable for RKB 125/ 150 HP Pumping Set.
Replacement of Balancing ring suitable for RKB 125/ 150 HP Pumping Set.
Supply, laying, fixing or passing through pipe , laid in trenches or fixed to pole/ wall or fixed to LT panel board, 1100 V grade heavy duty cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 185 sqmm, 3.5 core with required aluminium cable lugs incl dismantling and taking down old unsv one complete all as specified and directed. Make - Havells/Finolex/Polycab/Grandlay.
S&F GI tubing 100mm bore medium grade for cable protection on pole/ trench including taking down old unsv one complete all as specified and directed.
Excavation in trenches not exc 1.5 m in width and 1.5m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning , filling including spreading levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removal of surplus soil of distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all as specified and directed.
Supply, laying, fixing or passing through pipe, testing and commissioning of 1100 V grade PVC sheathed unarmoured cable LT, XLPE insulated copper conductor and overall PVC sheathed of size 150 sqmm, single core including copper cable lugs as per site requirement including taking down old unsv one complete all as specified and directed. Make - Havells/Finolex/Polycab.
Supply, laying, fixing or passing through pipe, testing and commissioning of 1100 V grade PVC sheathed unarmoured cable LT, XLPE insulated copper conductor and overall PVC sheathed of size 120 sqmm, single core including copper cable lugs as per site requirement including taking down old unsv one complete all as specified and directed. Make - Havells/Finolex/Polycab.
S&F in repairs Ball bearing No. 7311 BECBP complete all as specified and directed.
Supply and fixing cast iron Sluice valve PN 1:6 as per IS-14846, body, dome, wedge-CI IS:210, rings bronze IS:318, Spindle-SS IS-6603, Gland Packing gresy jute packing, fasteners-CS, Gasket-Natural rubber, Nominal size DN-150mm, both ends flanged in existing line without damaging to existing pipe line, fixed as in repair including dismentling taking down old unserviceable one complete all as specified and directed by Engineer-in-charge. Note :- Suitable size flanges for existing pipe line, joints and jointing material shall be included under this item. Make : Kirloskar / Leader / Zoloto / L&T (Audco)
All as per item serial No. 28 here-in-before but nominal size DN-100mm bore -ditto-
Supplying, fixing and testing of cast iron swing check non return valve PN 1.6 as per IS 5312 part I,body, dome, wedge - CI, IS 210, rings bronze,IS:318, Door - CI IS:210, Door face - natural rubber Gland packing gresy jute packing, fasterner,CS, gasket - Natural rubber, nominal size DN - 150 mm both ends flanged complete all as specified and as directed. Note-: Suitable size flange, joints and jointing materials shall be included under this item. Make : Kirloskar / Leader / Zoloto / L&T (Audco)
All as per item serial No. 30 here-in-before but nominal size DN-80mm bore -ditto-
M&L for PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in concrete pedastal for platform / supporting the CI/GI pipes including necessary form work including demolition of existing pedastal complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below notmal ground level, connected to galvanised iron earth strip 32x6mm upto test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI wire protection pipe 50mm bore up to main board completew as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete ass as specified and testing on completion complete ass as specified and directed by Engineer-in-charge. Note - The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (light grade) for watering 50mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
Supply, fixining and testing of Foot Valve PN 1.6 as per IS 5312 part -I, nominal size DN-150mm single end flanged complete all as specified and directed. Note :- Suitable size flange, joints and jointing materials shall be included under this item. Make : Kirloskar/ Leader/ Zoloto/ L&T (Audco).
All as per item serial No. 34 here-in-before but nominal size DN-80mm bore -ditto-
M&L for laying clean and dry sand in trenches / ducts for bedding and cushioning to cable complete all as specified and directed. Note : Only Punned down thickness shall be measured and paid.
Supply and laying unreinforced precast concrete cable cover, class LV. Type 1, flat , size 250mmx150mmx40mm complete all as specified and directed.
M/S ASHOK CONSTRUCTION
M/S DKT CONSTRUCTION
D.P. Traders
M/S YOGENDRA CONSTRUCTION CO
M/S TENZING ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .