| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.0 LAccepted-AOC 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | ₹4.0 L | 1 | Accepted-AOC ACCEPTED |
| 2 | 2₹4.1 LRejected-AOC | ₹4.1 L | 2 | Rejected-AOC REJECTED |
| Sl No | Description | Qty | Unit | rv electricals L1 | SUN ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00 | Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers. | 5.32 | 1M3 (One Cubic metre) | 198 ₹1,053.36 | 200 ₹1,064 |
| 2.00 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means | 0.57 | 1M3 (One Cubic metre) | 5,540 ₹3,157.80 | 5,596 ₹3,189.72 |
| 3.00 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500,
Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel
reinforcement and G.I. binding wire, wastage etc. complete complying with standard
specification and as directed by the departmental officers.(Contractor has to make his
own arrangements for the supply of steel reinforcement and binding wire) | 400 | 1Kg(One Kilo Gram) | 94 ₹37,600 | 96 ₹38,400 |
| 4.00Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be rovided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).. | |||||
| 4.10 | For Footing | 2.28 | 1M2 (One square metre) | 645 ₹1,470.60 | 653 ₹1,488.84 |
| 4.20 | For Circular Columns | 5.32 | 1M2 (One square metre) | 1,293 ₹6,878.76 | 1,306 ₹6,947.92 |
| 5.00 | Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). | 2.02 | 1M3 (One Cubic metre) | 8,290 ₹16,745.80 | 8,373 ₹16,913.46 |
| 6.00 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers. | 4.19 | 1M3 (One Cubic metre) | 160 ₹670.40 | 163 ₹682.97 |
| 7.00 | Supplying & fixing of high mast (12 Metre) with 6 Nos. 300W LED Fitting including all cost of materials and labour charges etc., completed | 1 | 1No (One number) | 3,14,000 ₹3.1 L | 3,15,000 ₹3.1 L |
| 8.00 | Earthing arrangements as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mmwith copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonrywork and with 38mm RCC cover slab for the brick masonry as per the standard specification and as directed by the Departmental Officers. | 1 | 1No (One number) | 3,100 ₹3,100 | 3,165 ₹3,165 |
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
2 Mar 2026, 3:00 pmClosed
COMMISSIONER
113 Thamilzh Salai(Palai Road) Thoothukudi Corporation
Providing of 12 Meter High Mast Light arrangements at STP near tharuvaikulam junction in Thoothukudi City municipal Corporation
2026_MAWS_665783_1
277/25-26/AEE(Electrical)
Open Tender
Electrical Works
60 days
THOOTHUKUDI CORPORATION
Refer tender Notice
2 documents required · 2 mandatory
₹0
₹5,000
26 Mar 2026
24 Feb 2026
2 Mar 2026
24 Feb 2026
2 Mar 2026
28 Feb 2026
Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be rovided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid)..
For Footing
For Circular Columns
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Supplying & fixing of high mast (12 Metre) with 6 Nos. 300W LED Fitting including all cost of materials and labour charges etc., completed
Earthing arrangements as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mmwith copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonrywork and with 38mm RCC cover slab for the brick masonry as per the standard specification and as directed by the Departmental Officers.
Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32Aneutral link and earth link (1" x 1/8" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TWreepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earthconnection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1 No 40 Amp 30MA Double Pole RCD / RCCB (Lower End) with suitable necessary connection
Supply and run of 2 of 4 sq.mm. (84 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade on double run of 7 / 20 GI bearer wire for service connection mains .
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_799664.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid