Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-Finance FATORDA GOA | L1 | Accepted-Finance L1 | |
| 2 | L2₹5.0 L+₹35,330.47 (7.54%)Rejected-Finance FATORDA GOA | NORTH GOA | GOA | 403530 | L2 | Rejected-Finance L2 |
Tender Value
₹4.7 L
EMD Value
₹9,421
Closing Date
15 Dec 2025, 10:00 amClosed
Executive Engineer
Office of Executive Engineer, Div IV, PWD Tonca
Electrical maintenance / repairs of 24 nos. Polling Booths under Chimbel - 16 Constituency for forthcoming Zilla Panchayat Election - 2025.
2025_PWD_26821_1
31/1/2025-26/ASW-IV/EMN/PWD/40 LINE03
Open Tender
Electrical Works
Percentage
4 days
Tonca Caranzalem
Please refer to tender notice
3 documents required · 3 mandatory
₹4,000
Yes
₹9,421
Yes
17 Mar 2026
11 Dec 2025
15 Dec 2025
11 Dec 2025
15 Dec 2025
11 Dec 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in PVC casing caping with modular switch modular plates suitable size modular surface box of specified Category and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.;(c) Group C -- with Cat B Modular Accessories
Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required.;(b) Cat B
Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(l) 8 Module Cat B
Supplying and fixing following size modular PVC box alongwith modular base and cover plate for modulator switches in recess etc. as required;(m) 12 Module Cat B
Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required;(h) 5/6 A switch Cat B
Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required;(k) 3 pin 5/6 A socket outlet Cat B
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required;(b) Cat B
Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator);(n) 8 way double door Cat B
Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(f) SP Cat B
Supply of 3 core unarmoured PVC/XLPE insulated PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;3 Core 1.5 sq.mm
Supply of 3 core unarmoured PVC/XLPE insulated PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;3 Core 2.5 sq.mm
Supply and fixing of LED Batten 4 feet 20 W with led tube as required of make Panasonic Passolite or equivalent.
Supply of 9W LED Bulb of Havells, Bajaj, Phillips, Panasonic, Anchor, Crompton.
Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).;(b) In rocky strata
Extra for using salt and charcoal for GI or copper plate earth electrode as required( 96 Kgs of Charcoal and 5 Kgs of Salt)
Supply & fixing of 14/0.30 twin core FRLS PVC sheathed flat flexible copper cable including laying/fixing on pole/wall etc. as required.
Supply and laying of service wire for providing connection to light fittings complete as required. a) 2 Core 4 sq.mm
Supply of Pedestal fan 16" sweep of make Havells / Bajaj/ Crompton / Usha / Almonard
'Supply of 30W LED street light fitting of IP 66 protection make Havells cat no. ENDURAPEARLSL30WLED757SASYTOPCMP, or Equivalent in Crompton, Bajaj, Orient, Panasonic may be approved by Engineer in charge.
Providing Electrician for the maintenance of Poling Booths
Providing Helper for the maintenance of Poling Booths
Hiring of utility vehicle with 4 door and carrier including driver and all other expenses etc. Complete for a period of 1 year for official use for day and night use as required viz, Tata/Mahindra or equivalent.
Supply and erecting of 48 inch (1200mm sweep) ceiling fan double ball bearing type complete with all accessories.;(b) Cat B
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
Tendernotice_2.pdf
PDF • 7.69 MB
BOQ_27266.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .