Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.1 LAdmitted-Finance 108 BADA CHAKA NAINI ALLAHABAD | ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | L1 | Admitted-Finance | |
| 2 | L2₹60.7 L+₹1.6 L (2.76%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹61.3 L+₹2.1 L (3.63%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SIDDHI ENTERPRISES L2 | PRACHI ENTERPRISES L3 | KHUSHI ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00Loading carriage & unloading of following materials from center store Daliganj to work site and its stacking. Distance approx. (0-35) kms. | ||||||
| 1.01 | 33 KV Lightening Arrester | 9 | Nos | 550 ₹4,950 | 510 ₹4,590 | 500 ₹4,500 Lowest |
| 1.02 | 33 KV VCB | 4 | Nos | 6,500 ₹26,000 | 6,100 ₹24,400 | 6,000 ₹24,000 Lowest |
| 1.03 | 33 KV C.T | 3 | Nos | 2,500 ₹7,500 | 2,100 ₹6,300 | 2,000 ₹6,000 Lowest |
| 1.04 | 33 KV T/F CONTROL PANNEL | 4 | Nos | 4,100 ₹16,400 | 4,100 ₹16,400 | 4,000 ₹16,000 Lowest |
| 1.05 | 33 KV POST INSULATOR | 6 | Nos | 120 ₹720 | 105 ₹630 | 100 ₹600 Lowest |
| 1.06 | 33 KV BUS ISOLATOR | 9 | Nos | 2,100 ₹18,900 | 2,050 ₹18,450 | 2,000 ₹18,000 Lowest |
| 1.07 | 33 KV LINE ISOLATOR | 3 | Nos | 2,100 ₹6,300 | 2,050 ₹6,150 | 2,000 ₹6,000 Lowest |
| 1.08 | ACSR CONDUCTOR PANTHAR | 800 | Mtr. | 11 ₹8,800 | 11 ₹8,800 | 10 ₹8,000 Lowest |
| 1.09 | 11 KV XLPE CABLE 3X300 sqmm | 350 | Mtr. | 15 ₹5,250 Lowest | 16 ₹5,600 | 15 ₹5,250 Lowest |
Tender Value
₹59.3 L
EMD Value
₹59,260
Closing Date
17 Sept 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE PURANIA, LUCKNOW
SE PURANIA, 33/11KV SUB STATION PURANIA, LUCKNOW
Re-Structuring of 33/11KV Sub Station Purania Yard in the work area of Sub Division Purania under the jurisdiction of EUDD-Daliganj, Lucknow
2025_MVVNL_1071471_1
24/EUDC-PURANIA/2025-26
Open Tender
Electrical Works
Item Wise
365 days
EUDD DALIGANJ
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EE.EDD BKT, LUCKNOW
₹59,260
Yes
20 Sept 2025
6 Sept 2025
17 Sept 2025
6 Sept 2025
17 Sept 2025
6 Sept 2025
Amount
Loading carriage & unloading of following materials from center store Daliganj to work site and its stacking. Distance approx. (0-35) kms.
33 KV Lightening Arrester
33 KV VCB
33 KV T/F CONTROL PANNEL
33 KV POST INSULATOR
33 KV BUS ISOLATOR
33 KV LINE ISOLATOR
ACSR CONDUCTOR PANTHAR
11 KV XLPE CABLE 3X300 sqmm
33 KV XLPE CABLE 3X300 sqmm
PCC POLE 8.5MTR
St pole 11 mtr long
MS Channel / MS Angle of Difference Size
Other Sub Station/ Line Materials
Laying of earthmat and earthing of Indoor & outdoor equipment’s of the Sub-Station after proper clamping and welding of joints including painting inside Soil as per RESPO/ Approved drawing details as given below all iron and steel material provided by contractor
Laying of M.S. Bar of 32mm dia for making the complete earthmat in the trenches in S/s Yard of 750mm depth and 500mm width with their straightening, cutting accordingly and welding with overlap joint of 100mm cross joint, T joint.
Making and driving of 3 Mtr. Long electrodes from 32mm dia M.S. Bar having one end conical 150mm long by heat tempering including cutting upto 750mm depth from ground level and welding with earth mat.
Making of triangular bridge by using M.S. electrodes and M.S. Strip 50x6mm with providing of well type pipe earthing upto 10 Mtr. Depth below G/L including welding etc. by boring process at T/F Neutral, LA and two side of 11 KV S/G including cost of GI Pipe of size 40mm dia 10 Mtr Long of ISI mark.
Welding & Laying of G.S. strip 50x6mm size with structures and all equipment’s in switchyard and control room, M.S. Bar including cutting, binding and proper fixing etc. complete. The welding and laying of G.S. Strips to L.A. with full length of structures and also the M.S. bridge near L.A. structures
Preparation of Power T/F plinth in size 4.5x3.5Mtr. 6 inches above ground level and fixing of rail pieces 2 Nos. as per RESPO/ Approved Drawing suitable upto 10 MVA load with complete material.
Earth filling inside and outside of the Sub-Station switchyard and also trenches excavated earlier as required upto plinth level including its carriage loading, unloading, ramming and proper dressing etc complete.
Fabrication, erection and grouting of the following structures as per RESPO/ Approved Drawing and its, plinth 45cm above ground level as directed by the Engineer In charge (All steel sections will be provided by Deptt).
Bus bar gentry (material provided by contractor)
Line isolator structure
Bus isolator Structure
Lightning Arrestor structure
33 KV VCB Structure with 3 No CTs
Neutal stand
Terminal gantry (material provided by contractor)
PT Structure
CT Structure
Disentailing (Mechanical & electrical) of Following equipment including loading unloading
33 KV Isolator line side
33 KV Isolator Bus side
Lightning Arrestor
33 KV VCB complete with CTs
Mounting and installation, including Mechanical & electrical fixing and adjusting of the following equipment on their respective structures including proper adjustment:
33 KV Isolator line side (to be provided by Deptt)
33 KV Isolator Bus side (To be provided by Deptt)
Lightning Arrestor (To be provided by Department)
33 KV VCB complete with CTs (To be provided by Deptt)
Dismantling of Old Iron Structure and carriage upto store
Temporary arrangement of 33 kv supply to existing system including laying of cable and material to be need for restoration of supply (all material provided by contractor except cable )
Disentailing of power transformer including radiator oil draining (drum provided by the contractor )
shifting of power transformer from existing plinth to new plinth
Centrifuging and refilling of oil
Erection, Fabrication, reaction of cable exposer type double pole on 11 Mtr. long ST pole along with fixing of necessary clamps. Accessories required including supply & fixing of straight MS 100x50mm top channel (2240 mm long) one no. dropper channel/Angle 100x50 mm 2 Nos. with arrangement of fixing 3 Nos pin insulator as per RESPO specification and direction of E/I. Only pole & insulator supplied by the dept.
Laying of cable double circuit 33 KV XLPE cable (3x70/120/170/185/300) sqmm in kaccha road by digging of trench laying cable with first class brick boxing and sand, as RESPO specification & direction of E/I.
Laying of cable double circuit 11 KV XLPE cable (3x70/120/170/185/300) sqmm in kaccha road by digging of trench laying cable with first class brick boxing and sand, as RESPO specification & direction of E/I.
Lighting arrangement of switch yard including erection of pole laying of cable as required Led light 240 watt -6 nos 40 watt -4 nos with mcb box and switch arrangement as per direction of site E/ Incharge
Wiring of control room including replacement of tube light damaged exhaust fan , ceiling fan , switch board ,extra light/fan with point as per requirement
Leveling and making of interlocking tiles inside the yard and making of approach road to power transformer, breaker ,isolators, plantation in switch yard/ substation using Cement/clay flower pot with small plant/flower.
Making of Cable trench for control cable as per norms
Earthing of Power TF / Sub Station Pipe type upto Water level deep boring and providing GI Pipe 1.5" dia and GI strip 65x5 mm attached with clamps. L piece, nut & bolts and GI pipe Cap. All material shall be supplied by the contractor.
Carriage of other material upto store as per site E/ Incharge
Other work as per requirement as per direction and Disc. Of site E/Incharge
Wiremess fencing of substation yard shall be made of rectangular of size per site requirement not exceeding 3 meter fabrication 45x45x5 mm angle the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mess. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as wll as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with MS flat of size 25x3mm to supports as per RESPO specification & direction of E/I. including painting of fencing with two coat of primer and two coat of enamel paint.
SIDDHI ENTERPRISES (BID ID -5529093)
PRACHI ENTERPRISES (BID ID -5536077)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .