As per NIT
Design, Engineering, Supply, Erection, Testing and commissioning 400 KV Quad Moose Double Circuit DC Transmission line on Double Circuit and Multi-Circuit towers from the existing 400/220 KV Pandiabil PGCIL Grid Substation to the proposed 400/220/33 KV Grid Substation at TSSEZ, Gopalpur Approx-157.363 km on EPC Contract basis.
CPC-65/2026-27::1
CPC-65/2026-27
Open Tender
Works
CPC, Bhubaneshwar
₹29,500
₹5.5 Cr
25 Aug 2026
25 Aug 2026
12 Nov 2026
25 Aug 2026
11 Nov 2026
Checklist for Bid Submission
1 Certificate regarding Certificate of Incorporation To be submitted in case company To be submitted in Soft Copy.
2 Soft copy of Attachments & Bid Form Duly Filled Excel Sheet of Attachment and Bid Form to be uploaded in Soft Copy along with Bid. To be submitted in Soft Copy.
3 Power of Attorney (POA) Duly notarized (on Stamp Paper of requisite value), indicating that the person(s) signing the bid has(ve) the authority to sign the bid. In case of bid submitted by a Joint Venture two (lead + other) partners, if allowed as per stipulated Qualification Requirements in Annexure-A (BDS), bidder shall submit. Power of Attorney for Joint Venture and Joint Venture Agreement as per given format Submission of Hard copy in ‘Original’and uploading of Scanned Copy
4 Bid Security The bid security shall, at the bidder’s option, be in the form of a crossed bank draft in favour of OPTCL or a bank guarantee from a reputed bank selected by the bidder. Alternatively, same can be submitted as online payment through OPTCL ONLINE PAYMENT “www.tenderwizard.com/OPTCL”, a link of which is provided on the. The copy of ‘Online Payment Acknowledgement – Suppliers’ generated subsequent to the payment shall be submitted along with hard copy part of the bid. The format of the bank guarantee shall be in accordance with the form of bid security included in the Bidding Documents. Bid security shall be valid upto 240 days from the date of Bid Opening. The Bid Security shall be in favour of Odisha Power Transmission Corporation Limited payable at Bhubaneswar. Submission of Hard copy and uploading of Scanned Copy
5 Bidding Document Fee Bid document cost for amount as specified in BDS- Hard copy of document related to online payment of bid document cost as indicated in BDS . Copy of the payment proof may be uploaded online on the portal. Submission of Hard copy and uploading of Scanned Copy
6 Tender Processing Fee Tender Processing Fee for amount as specified in BDS- Hard copy of document related to online payment of Tender Processing Feeas indicated in BDS. Copy of the payment proof may be uploaded online on the portal. Submission of Hard copy and uploading of Scanned Copy
7 Attachment-8: Manufacturers Authorization Form (if applicable) To be submitted on Company's Letterhead. Signed and stamped with company seal by a full time Director/ CEO/ Chairman-cum-Managing Director. Submission of Hard copy and uploading of Scanned Copy
8 Attachment-14: Integrity Pact To be submitted on a non-judicial stamp paper of Rs. 100/-. (in two originals, Signed on each page by Power of Attorney Holder and duly witnessed) Submission of Hard copy in ‘Original’ and uploading of Scanned Copy
9 Attachment-18: Safety Pact To be submitted on a non-judicial stamp paper of Rs. 100/-. (in two originals, Signed on each page by Power of Attorney Holder and duly witnessed) Submission of Hard copy in ‘Original’ and uploading of Scanned Copy
10 Attachment 20: Declaration of Key Managerial Person jointly with Power of Attorney holder Signed by CEO/Managing Director/Company Secretary/ Director/ CFO/ any of the partner in case of partnership firm/ any other officer entrusted with substantial powers of the management of the affairs of the company/firm and POA Holder To be submitted in Soft Copy.
11 Attachment 23: Compliance to the process of E-Reverse Auction. On Company's Letterhead To be submitted in Soft Copy.
12 Attachment-24: Declaration by the bidder regarding events encountered pursuant to ITB Clause 2.1. (In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture) On Company's Letterhead To be submitted in Soft Copy.
15 Attachment-27: Certification by the Bidder as per order no. F.No.6/18/2019-PPD dated 23/07/2020 issued by Public Procurement Division, Department of Expenditure, Ministry of Finance, Government of India (DoE Order) in line with ITB 2.1 (In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture) Company's Letterhead To be submitted in Soft Copy.
16 Attachment 28: Power of Attorney by Joint Venture partners To be submitted on a non-judicial stamp paper of Rs. 100/-. (in two originals, Signed on each page by Power of Attorney Holder and duly witnessed) Submission of Hard copy in ‘Original’ and uploading of Scanned Copy
17 Attachment 29: Joint Deed of Undertaking by Joint Venture partners To be submitted on a non-judicial stamp paper of Rs. 100/-. (in two originals, Signed on each page by Power of Attorney Holder and duly witnessed) Submission of Hard copy in ‘Original’ and uploading of Scanned Copy
18 Documents for Qualifying Requirement (QR) In support of meeting the qualifying requirements (QR) such as copy of letter of award/ work order, completion certificate, copy of audited balance sheet for five years etc., shall be uploaded by the bidder along on the portal as part of technical bid To be submitted in Soft Copy.
NOTE: This checklist is not exhaustive and issued for the purpose of reference Only. In case of any ambiguity, the provisions of Bidding Documents shall prevail.
GUARANTEED WEIGHTS OF STUBS, TOWERS SUPER STRUCTURE AND EXTENSIONS WITH BOLTS & NUTS AND SPRING WASHERS SEPARATELY FOR 400kV DOUBLE CIRCUIT & MULTI CIRCUIT TOWER WITH ACSR QUAD MOOSE CONDUCTOR FOR WIND ZONE-V
No. of Towers offered 1. Tangent Tower - DA (up to +9m)- 1 No. 2. Angle Tower - DB (up to +9m)- 1 No. 3. Angle Tower - DC (up to +9m)- 1 No. 4. Angle Tower - DD (up to +9m)- 1 No. 5. Tangent Tower- QA (up to +9m)- 1 No. 6. Angle Tower- QB (up to +9m)- 1 No. 7. Angle Tower- QC (up to +9m)- 1 No. 8. Angle Tower- QD (up to +9m) (30°-45°)- 1 No. 9. Angle Tower- QD (up to +9m/+18m) (45°-60°)- 1 No.
S. No DESCRIPTION WEIGHT OF STRUCTURE EXCLUDING BOLT & NUTS, STEP BOLTS, SPRING & PACK WASHERS WEIG HT OF NUTS & BOLTS WEIGHT OF SPRING WASHER WEIGHT OF STEP BOLTS WEIGHT OF PACKING WASHERS OVERALL WEIGHT
1 STUBS & CLEATS SUITABLE FOR:-
1.1 Tangent tower DA (up to +9m)
1.2 Angle type tower DB (up to +9m)
1.3 Angle type tower DC (up to +9m)
1.4 Dead End tower DD (up to +9m)
1.5 Tangent tower QA (up to +9m)
1.6 Angle type tower QB (up to +9m)
1.7 Angle type tower QC (up to +9m)
1.8 Dead End tower QD (up to +9m) (30°-45°)
1.9 Dead End tower QD (up to +9m) (45°-60°)
1.10 Dead End tower QD (up to +18m) (45°-60°)
2 SUPER STRUCTURE / EXTENSIONS
2.1 Tangent tower DA for ACSR QUAD MOOSE
2.1.1 Normal Tower
2.1.2 +3m Extension
2.1.3 +6m Extension
2.1.4 +9m Extension
2.2 Angle type tower DB for ACSR QUAD MOOSE
2.2.1 Normal Tower
2.2.2 +3m Extension
2.2.3 +6m Extension
2.2.4 +9m Extension
2.3 Angle type tower DC for ACSR QUAD MOOSE
2.3.1 Normal Tower
2.3.2 +3m Extension
2.3.3 +6m Extension
2.3.4 +9m Extension
2.4 Dead End tower DD for ACSR QUAD MOOSE
2.4.1 Normal Tower
2.4.2 +3m Extension
2.4.3 +6m Extension
2.4.4 +9m Extension
2.5 Tangent tower QA for ACSR QUAD MOOSE
2.5.1 +3m Extension
2.5.2 +6m Extension
2.5.3 +9m Extension
2.6 Angle tower QB for ACSR QUAD MOOSE
2.6.1 +3m Extension
2.6.2 +6m Extension
2.6.3 +9m Extension
2.7 Angle tower QC for ACSR QUAD MOOSE
2.7.1 +3m Extension
2.7.2 +6m Extension
2.7.3 +9m Extension
2.8 Dead End tower QD (30°-45°)
2.8.1 +3m Extension
2.8.2 +6m Extension
2.8.3 +9m Extension
2.9 Dead End tower QD (45°-60°)
2.9.1 +3m Extension
2.9.2 +6m Extension
2.9.3 +9m Extension
2.9.4 +18m Extension
2.10 STUB SETTING TEMPLATE
2.10.1 Tangent tower DA (up to +9m)
2.10.2 Angle type tower DB (up to +9m)
2.10.3 Angle type tower DC (up to +9m)
2.10.4 Dead End tower DD (up to +9m)
2.10.5 Tangent tower QA (up to +9m)
2.10.6 Angle type tower QB (up to +9m)
2.10.7 Angle type tower QC (up to +9m)
2.10.8 Dead End tower QD (30°-45°)(up to +9m)
2.10.9 Dead End tower QD (45°-60°)(up to +9m)
GUARANTEED VOLUMES OF EXCAVATION, CONCRETING AND WEIGHT OF REINFORCED STEEL PER TOWER FOR 400kV DOUBLE CIRCUIT & MULTI CIRCUIT TOWERS WITH QUAD MOOSE CONDUCTOR
S.no Description No. of towers Volume of excavation in cum Volume of M20 (1:1.5:3) concreting Volume of lean concrete 1:3:6 ratio Weight of reinforcement in kg.
1 IN NORMAL & DRY SOIL FOR :
1.1 Tangent tower DA (up to +9m) 1
1.2 Angle type tower DB (up to +9m) 1
1.3 Angle type tower DC (up to +0m) 1
1.4 Dead End tower DD (up to +9m) 1
1.5 Tangent tower QA (up to +9m) 1
1.6 Angle type tower QB (up to +9m) 1
1.7 Angle type tower QC (up to +9m) 1
1.8 Dead End tower QD (30-45) (up to +9m) 1
1.9 Dead End tower QD (45-60) (up to +9m) 1
1.10 Dead End tower QD (45-60) ( +18m) 1
2 IN WET SOIL FOR :
2.1 Tangent tower DA (up to +9m) 1
2.2 Angle type tower DB (up to +9m) 1
2.3 Angle type tower DC (up to +0m) 1
2.4 Dead End tower DD (up to +9m) 1
2.5 Tangent tower QA (up to +9m) 1
2.6 Angle type tower QB (up to +9m) 1
2.7 Angle type tower QC (up to +9m) 1
2.8 Dead End tower QD (30-45) (up to +9m) 1
2.9 Dead End tower QD (45-60) (up to +9m) 1
2.10 Dead End tower QD (45-60) ( +18m) 1
3 PARTIALY SUBMERGED
3.1 Tangent tower DA (up to +9m) 1
3.2 Angle type tower DB (up to +9m) 1
3.3 Angle type tower DC (up to +0m) 1
3.4 Dead End tower DD (up to +9m) 1
3.5 Tangent tower QA (up to +9m) 1
3.6 Angle type tower QB (up to +9m) 1
3.7 Angle type tower QC (up to +9m) 1
3.8 Dead End tower QD (30-45) (up to +9m) 1
3.9 Dead End tower QD (45-60) (up to +9m) 1
3.10 Dead End tower QD (45-60) ( +18m) 1
4 FULLY SUBMERGED SOIL FOR:
4.1 Tangent tower DA (up to +9m) 1
4.2 Angle type tower DB (up to +9m) 1
4.3 Angle type tower DC (up to +0m) 1
4.4 Dead End tower DD (up to +9m) 1
4.5 Tangent tower QA (up to +9m) 1
4.6 Angle type tower QB (up to +9m) 1
4.7 Angle type tower QC (up to +9m) 1
4.8 Dead End tower QD (30-45) (up to +9m) 1
4.9 Dead End tower QD (45-60) (up to +9m) 1
4.10 Dead End tower QD (45-60) ( +18m) 1
5 BLACK COTTON SOIL FOR :
5.1 Tangent tower DA (up to +9m) 1
5.2 Angle type tower DB (up to +9m) 1
5.3 Angle type tower DC (up to +0m) 1
5.4 Dead End tower DD (up to +9m) 1
5.5 Tangent tower QA (up to +9m) 1
5.6 Angle type tower QB (up to +9m) 1
5.7 Angle type tower QC (up to +9m) 1
5.8 Dead End tower QD (30-45) (up to +9m) 1
5.9 Dead End tower QD (45-60) (up to +9m) 1
5.10 Dead End tower QD (45-60) ( +18m) 1
6 DRY FISSURED ROCK FOR :-
6.1 Tangent tower DA (up to +9m) 1
6.2 Angle type tower DB (up to +9m) 1
6.3 Angle type tower DC (up to +0m) 1
6.4 Dead End tower DD (up to +9m) 1
6.5 Tangent tower QA (up to +9m) 1
6.6 Angle type tower QB (up to +9m) 1
6.7 Angle type tower QC (up to +9m) 1
6.8 Dead End tower QD (30-45) (up to +9m) 1
6.9 Dead End tower QD (45-60) (up to +9m) 1
6.10 Dead End tower QD (45-60) ( +18m) 1
7 SUBMERGED FISSURED ROCK FOR :
7.1 Tangent tower DA (up to +9m) 1
7.2 Angle type tower DB (up to +9m) 1
7.3 Angle type tower DC (up to +0m) 1
7.4 Dead End tower DD (up to +9m) 1
7.5 Tangent tower QA (up to +9m) 1
7.6 Angle type tower QB (up to +9m) 1
7.7 Angle type tower QC (up to +9m) 1
7.8 Dead End tower QD (30-45) (up to +9m) 1
7.9 Dead End tower QD (45-60) (up to +9m) 1
7.10 Dead End tower QD (45-60) ( +18m) 1
8.1 Tangent tower DA (up to +9m) 1
8.2 Angle type tower DB (up to +9m) 1
8.3 Angle type tower DC (up to +0m) 1
8.4 Dead End tower DD (up to +9m) 1
8.5 Tangent tower QA (up to +9m) 1
8.6 Angle type tower QB (up to +9m) 1
8.7 Angle type tower QC (up to +9m) 1
8.8 Dead End tower QD (30-45) (up to +9m) 1
8.9 Dead End tower QD (45-60) (up to +9m) 1
8.10 Dead End tower QD (45-60) ( +18m) 1
9 SANDY SOIL FOR :-
9.1 Tangent tower DA (up to +9m) 1
9.2 Angle type tower DB (up to +9m) 1
9.3 Angle type tower DC (up to +0m) 1
9.4 Dead End tower DD (up to +9m) 1
9.5 Tangent tower QA (up to +9m) 1
9.6 Angle type tower QB (up to +9m) 1
9.7 Angle type tower QC (up to +9m) 1
9.8 Dead End tower QD (30-45) (up to +9m) 1
9.9 Dead End tower QD (45-60) (up to +9m) 1
9.10 Dead End tower QD (45-60) ( +18m) 1
10 RIVERBED PILE FOUNDATION
10.1 Tangent tower DA (up to +9m) 1
10.2 Angle type tower DB (up to +9m) 1
10.3 Angle type tower DC (up to +0m) 1
10.4 Dead End tower DD (up to +9m) 1
10.5 Tangent tower QA (up to +9m) 1
10.6 Angle type tower QB (up to +9m) 1
10.7 Angle type tower QC (up to +9m) 1
10.8 Dead End tower QD (30-45) (up to +9m) 1
10.9 Dead End tower QD (45-60) (up to +9m) 1
10.10 Dead End tower QD (45-60) ( +18m) 1
VOLUMES OF EXCAVATION, CONCRETING AND WEIGHT OF REINFORCED STEEL PER TOWER FOR 400kV MULTI CIRCUIT TOWERS ON TWIN ACSR MOOSE CONDUCTOR
S.no Type of Tower & Location No. Type of foundation Volume of excavation in cum Volume of M20 (1:1.5:3) concreting Volume of lean concrete 1:3:6 ratio Weight of reinforcement in kg.
Work Completion schedule
Sl No. Name of Activity Period (30 months) (Activity in days)
1 Acknowledgement of LOA/NOA 0-7
2 Signing of thye Contract Agreement 0-30
3 Drawing/design approval 30-90
4 Supply of equipment at site Materials (To be supplied in Phased manner 90-510
5 Civil works of the Pacakge/Works 90-660
6 Erection & installation work of the Package/Works (to be executed as per the PERT/BAR Chart) 90-725
7 Testing and Pre-Commissioning 725-790
8 Charging of Transmission Line 790-830
9 Handing Over of Transmission Line 830-900
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
TenderNoticeCPC65.pdf
pdf • 0.19 MB
Vol_I_Vol-I_00- Bidding Document for bid_OPTCL_Pandiabil-Gopalpur.docx
docx • 0.76 MB
Vol_I_Vol-I_01- IFB_Invitation_for_Bid_OPTCL_ Gopalpur-Pandiabil.docx
docx • 0.07 MB
Vol_I_Vol-I_02- Section - II ITB -Instruction to Bidder_OPTCL Gopalpur_Pandiabil.docx
docx • 0.16 MB
Vol_I_Vol-I_03- Section-III-BDS _Bid data Sheet_OPTCL_Gopalpur_Pandiabil.docx
docx • 0.06 MB
Vol_I_Vol-I_04-Annexure-A (BDS)_Qualification of bidder_OPTCL_Gopalpur_Pandiabil.docx
docx • 0.07 MB
Vol_I_Vol-I_05-Annexure-B to BDS_e-Reverse auction_OPTCL_Gopalpur_Pandiabil.docx
docx • 0.04 MB
Vol_I_Vol-I_06-Annexure-C to BDS_Sample format for e-Reverse auction_OPTCL-Gopalpur_Pandiabil.doc
doc • 0.04 MB
Vol_I_Vol-I_07-Section - IV GCC -General Condition of Contract_OPTCL_Gopalpur_Pandiabil.docx
docx • 0.20 MB
Vol_I_Vol-I_08- Section-V-SCC -Special Condition of Contract_OPTCL_Gopalpur_Pandiabil.docx
docx • 0.06 MB
Vol_I_Vol-I_09- Annexure-I to Section-V (SCC)_List of Name of Nationilised and Private Bank_OPTCL_Gopalpur_Pandiabil.docx
docx • 0.02 MB
Vol_I_Vol-I_10- Appendix-I to Section-V (SCC)-Environmental Management Plan_OPTCL_Gopalpur_Pandiabil.doc
doc • 0.72 MB
Vol_I_Vol-I_11-Section - VI -Forms and Procedures incl Terms of payment_OPTCL_Gopalpur_Pandiabil.docx
docx • 0.38 MB
Vol_I_Vol-I_12-General Information to bidder-Clauses for Bid Outright rejection non responsive etc.-.docx
docx • 0.02 MB
Vol_I_Vol-I_13-Vol-III_10-Checklist_OPTCL.xlsx
xlsx • 0.01 MB
Vol_I_Vol-I_14-Vol-III_10-Legends_OPTCL.pdf
pdf • 0.03 MB
Vol_I_Vol-I_15-Format of Insurance Surety Bond (3).pdf
pdf • 0.63 MB
Vol_I_Vol-I_16- Annexure-II (a) Guaranteed_values_Structures.xlsx
xlsx • 0.01 MB
Vol_I_Vol-I_17-Annexure-II (b) Guaranteed_values-Foundation.xlsx
xlsx • 0.02 MB
Vol_I_Vol-I_18-Work completion schedule.xlsx
xlsx • 0.01 MB
TS_A_E10-GENERAL EQUIPMENT SUBSTATION ACCESSORIES.pdf
pdf • 0.97 MB
TS_A_E43-HTLS CONDUCTOR HARDWARE FITTINGS ACCESSORIES.pdf
pdf • 0.83 MB
TS_A_E41-TESTING INSTRUMENTS T P OFFICE FURNITURE.pdf
pdf • 0.16 MB
TS_A_E37-SAS CR PANEL.pdf
pdf • 5.33 MB
TS_A_E32-DIGITAL POWER LINE CARRIER EQUIPMENT TELEPROTECTION.pdf
pdf • 0.53 MB
TS_A_E28B-DIESEL GENERATORS (250 500KVA).pdf
pdf • 1.45 MB
TS_A_E28A-DISEL GENERATORS (82.5 160KVA).pdf
pdf • 0.17 MB
TS_A_E27-OPGW ACCESSORIES.pdf
pdf • 1.48 MB
TS_A_E25-TESTING INSTRUMENTS MAINTENANCE KITS OTHER T P.pdf
pdf • 1.64 MB
TS_A_E23-LT CONTROL POWER CABLES.pdf
pdf • 2.92 MB
TS_A_E20B- HARDWARE FITTINGS CLAMPS CONNECTORS ACCESSORIES.pdf
pdf • 1.84 MB
TS_A_E20A-CONDUCTOR EARTH WIRE.pdf
pdf • 2.14 MB
TS_A_E18-48V VRLA BATTERY SMPS BATTERY CHARGER.pdf
pdf • 1.62 MB
TS_B_E29-FIRE PROTECTION SYSTEM.pdf
pdf • 1.18 MB
TS_B_E9-ELECTRICAL EQUIPMENT INSTALLATION COMMISSIONING-1.pdf
pdf • 0.49 MB
TS_B_E8-DRAWING TEST CERTIFICATES AND O M MANUALS.pdf
pdf • 0.53 MB
TS_B_E42-MONOPOLE TOWERS.pdf
pdf • 0.63 MB
TS_B_E40-TRANSFORMERS FOR 765KV.pdf
pdf • 1.86 MB
TS_B_E39-REACTORS.pdf
pdf • 1.79 MB
TS_B_E38-TRANSFORMERS UPTO 400KV.pdf
pdf • 2.69 MB
TS_B_E36-PEB GIS BUILDING.pdf
pdf • 1.14 MB
TS_B_E35-FIBER OPTIC TERMINAL EQUIPMENT.pdf
pdf • 1.00 MB
TS_B_E33D-PORCELAIN LONGROD INSULATORS.pdf
pdf • 1.29 MB
TS_B_E33C-SOLID CORE POST INSULATORS.pdf
pdf • 1.16 MB
TS_B_E33B-COMPOSITE LONGROD INSULATORS.pdf
pdf • 1.77 MB
TS_B_E33A-PORCELAIN ANTI FOG DISC INSULATORS.pdf
pdf • 1.39 MB
TS_B_E30- GAS INSULATED SWITCHGEARS.pdf
pdf • 2.90 MB
TS_C_E7-SWITCHYARD STRUCTURE.pdf
pdf • 0.51 MB
TS_C_E31-220KV-132KV-33KV XLPE POWER CABLE.pdf
pdf • 1.37 MB
TS_C_E26-TRANSMISSION LINES.pdf
pdf • 1.04 MB
TS_C_E24-SUBSTATION LIGHTING.pdf
pdf • 0.79 MB
TS_C_E22-AIR CONDITIONERS.pdf
pdf • 0.39 MB
TS_C_E21-TOWER DESIGN.pdf
pdf • 1.20 MB
TS_C_E19-LT DISTRIBUTION BOARDS.pdf
pdf • 1.48 MB
TS_C_E17B-220V VRLA BATTERY CHARGER.pdf
pdf • 1.40 MB
TS_C_E17A-220V VRLA BATTERY.pdf
pdf • 1.12 MB
TS_C_E16B-CVT.pdf
pdf • 1.52 MB
TS_C_E16A-IVT.pdf
pdf • 1.46 MB
TS_C_E15-SURGE ARRESTERS.pdf
pdf • 1.57 MB
TS_C_E14-STATION TRANSFORMERS.pdf
pdf • 0.59 MB
TS_C_E13-ISOLATORS.pdf
pdf • 0.90 MB
TS_C_E12-CURRENT TRANSFORMERS.pdf
pdf • 1.87 MB
TS_C_E11-CIRCUIT BREAKER.pdf
pdf • 1.92 MB
TS_D_E6-CIVIL WORKS.pdf
pdf • 7.64 MB
TS_D_E5-DESIGN OF SUBSTATION.pdf
pdf • 0.66 MB
TS_D_E4-METEROLOGICAL DATA.pdf
pdf • 0.38 MB
TS_D_E3-SYSTEM DATA.pdf
pdf • 0.62 MB
TS_D_E2- GENERAL TECHNICAL CLAUSES FOR DESIGN.pdf
pdf • 0.93 MB
TS_D_E1-GENERAL CLAUSE.pdf
pdf • 0.62 MB
TS_D_E0-Contents of TS.pdf
pdf • 0.21 MB
addendum1.pdf
pdf • 0.18 MB
corrigendum2.pdf
pdf • 0.18 MB
corrigendum1.pdf
pdf • 0.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .