Loading…
Loading…
Tender Value
₹9.5 L
EMD Value
₹18,913
Closing Date
16 Jun 2026, 2:00 pmDue today
NISHANT BATTAN
Pundri W.S Divn. Kaithal
Estimate for extenstion of RCC Pipeline for disposal of flood water into existing pipeline in village Dussain near Ahun Road.
2026_HRY_528381_1
2026F42CC7FC 426F 4B37 8005 4E3167C87C91112IRR
Open Tender
Civil Works
30 days
DOSAIN
3 documents required · 3 mandatory
₹1,000
₹18,913
Yes
11 Jun 2026
11 Jun 2026
16 Jun 2026
11 Jun 2026
16 Jun 2026
11 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1HSR Items | ||||||
| 1.01 | [11.5.2]12 mm cement plaster of mix : 2. 1:3 (1 cement: 3 fine sand) | - | Sqm | 126 | - | BI01010001010000000000000515BI0100001113 |
| 1.02 | [21.95.5]Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, and item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: 5. 600 mm | - | Metre | 2,568 | - | BI01010001010000000000000515BI0100001114 |
| 1.03 | [4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil | - | cum | 78 | - | BI01010001010000000000000515BI0100001115 |
| 1.04 | [4.16.1.3]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.3. All kind of soil Pipes, cables etc, exceeding 300 mm dia but not exceeding 600 mm dia. | 1 | Metre | 131 | ₹130.87 | BI01010001010000000000000515BI0100001116 |
| 1.05 | [4.17]Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). | 1 | Metre | 3 | ₹3 | BI01010001010000000000000515BI0100001117 |
| 1.06 | [6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | - | cum | 3,476 | - | BI01010001010000000000000515BI0100001118 |
| 1.07 | [6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) | - | cum | 4,374 | - | BI01010001010000000000000515BI0100001114 |
| 1.08 | [6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete | 1 | Sqm | 156 | ₹155.84 | BI01010001010000000000000515BI0100001115 |
| 1.09 | [6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more | - | Kg. | 66 | - | BI01010001010000000000000515BI0100001116 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
BOQ_607383.xls
BOQ • 0.25 MB
AD0168157.pdf
Additional Documents • 0.65 MB
Download all tender documents and submit your bid