Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAdmitted-Finance 126 JULEDHA SARDHANA SARDHANA MEERUT UTTAR PRADESH 250342 | MEERUT | UTTAR PRADESH | 250342 | L1 | Admitted-Finance | |
| 2 | L2₹13.8 L+₹74,000 (5.67%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹14.1 L+₹1.1 L (8.44%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹16.0 L+₹3.0 L (22.7%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | Rejected-Technical | - | Rejected-Technical Incomplete Document |
| Sl No | Description | Qty | Unit | M/S RAGHAV and BROTHERS L2 | M/S DHARAM DASS & BUDH PRAKASH & CO. L1 | Navitech Technologies Pvt. Ltd. L4 | Mahalaxmi Electricals and Developers L3 |
|---|---|---|---|---|---|---|---|
| 1.00Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :- | |||||||
| 1.01 | 33 KV Lightening arrestor (EDD-1=7, EDD-3=6, EDD-IV=7) | 20 | Nos | 100 ₹2,000 Lowest | 2,000 ₹40,000 | 4,500 ₹90,000 | 425 ₹8,500 |
| 2.00 | Installation of 33 KV Lightening arrestor (as per UPPCL Respo)
(EDD-1=7, EDD-3=6, EDD-IV=7) | 20 | Nos | 500 ₹10,000 Lowest | 3,500 ₹70,000 | 5,000 ₹1,00,000 | 800 ₹16,000 |
| 3.00Providing fixing and Commissioning of numerical relay that should have protection for 3 OC+1 EF having following technical Parameters. Note:-The material should be of PVVNL approved vendor) | |||||||
| 3.01 | (i) Current rating: 1A/5A Site Selectable.
(ii) Aux Supply: 180-240V AC +24V DC Rated (As per IEC) with Communicable Port.
(iii) Draw Out with CT Shorting.
(iv) Front LEDs Display for following:- L1, L2, L3, E, Trip for Faulty Phase/Earth, Low Set Trip, High Set Trip.
(v) Relay should have minimum 4 DI, 6 DO.
(vii) The relay should have Cold Load pick up, Harmonic Blocking and CBFP. It should have minimum 10 Fault records and 10 Events records.
a lp>5 to 400% in step of 1%.
b lp>5 to 3000% in step of 1%.
c le>5 to 250% in step of 1%.
d le>5 to 1500% in step of 1%.
e Te>0.02 Sec to 20 sec in step of 0.01 Sec.
f Ti>0.02 Sec to 20 sec in step of 0.01 Sec.
Note:-
Breaker Failure Detectiion.
Communication Ports: RS485/RS232.
Communication Protocols: MODBUS-RTU&IEC 60870-5-103.
Programming through local keypad.
Selectable definite Time or IDMT curves as per IEC standards.
Rated input current selectable 1A or 5A.
Password protection to guard against unauthorized access & editing of setting.
Storage of latest 10 fault records with time stamping.
Mounting/Case:Draw-out/Non Draw-out.
Trip Circuit Supervision through digital input.
(EDD-1=13, EDD-3=13, EDD-IV=14) | 40 | Nos | 25,000 ₹10,00,000 | 18,000 ₹7,20,000 Lowest | 28,000 ₹11,20,000 | 21,000 ₹8,40,000 |
| 4.00 | Providing and Commissioning of Master Trip relay in Power T/f at various 33/11 kv Sub station. (EDD-1=18, EDD-3=18, EDD-IV=18) | 54 | Nos | 5,000 ₹2,70,000 | 7,000 ₹3,78,000 | 3,500 ₹1,89,000 Lowest | 8,800 ₹4,75,200 |
| 5.00 | Replacement of defective of WTI in 10/8/5 MVA Power Transformer (as per sample provided by department). (EDD-1=04, EDD-3=04, EDD-IV=04) | 12 | Nos | 4,000 ₹48,000 | 4,000 ₹48,000 | 3,900 ₹46,800 | 3,100 ₹37,200 Lowest |
| 6.00 | Replacement of defective of OTI 10/8/5 MVA Power Transformer (as per sample provided by department). (EDD-1=04, EDD-3=04, EDD-IV=04) | 12 | Nos | 4,000 ₹48,000 | 4,000 ₹48,000 | 4,500 ₹54,000 | 3,100 ₹37,200 Lowest |
Tender Value
₹17 L
EMD Value
₹17,000
Closing Date
12 Sept 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
SE, EDC-1, Meerut
ETN0-35/EDC-1/MT/2025-26
2025_PVVNL_1069503_1
ETNo.35/EDC-1/MT/2025-2026
Open Tender
Electrical Works
Lump-sum
180 days
Under EDC-1
ETN0-35/EDC-1/MT/2025-26
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER
₹17,000
23 Sept 2025
29 Aug 2025
12 Sept 2025
29 Aug 2025
12 Sept 2025
29 Aug 2025
Amount
Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :-
33 KV Lightening arrestor (EDD-1=7, EDD-3=6, EDD-IV=7)
Installation of 33 KV Lightening arrestor (as per UPPCL Respo) (EDD-1=7, EDD-3=6, EDD-IV=7)
Providing fixing and Commissioning of numerical relay that should have protection for 3 OC+1 EF having following technical Parameters. Note:-The material should be of PVVNL approved vendor)
Providing and Commissioning of Master Trip relay in Power T/f at various 33/11 kv Sub station. (EDD-1=18, EDD-3=18, EDD-IV=18)
Replacement of defective of WTI in 10/8/5 MVA Power Transformer (as per sample provided by department). (EDD-1=04, EDD-3=04, EDD-IV=04)
Replacement of defective of OTI 10/8/5 MVA Power Transformer (as per sample provided by department). (EDD-1=04, EDD-3=04, EDD-IV=04)
M/S RAGHAV and BROTHERS (BID ID -5527100)
Mahalaxmi Electricals and Developers (BID ID -5529325)
Navitech Technologies Pvt. Ltd. (BID ID -5529996)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .