| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹2.3 Cr+₹13,113 (0.06%)Accepted-AOC | ₹2.3 Cr+₹13,113 (0.06%) | L2 | Accepted-AOC Awarded |
| 2 | L1₹2.3 CrRejected-AOC | ₹2.3 Cr | L1 | Rejected-AOC Rejected |
| 3 | L2₹2.3 Cr+₹13,113 (0.06%)Rejected-AOC | ₹2.3 Cr+₹13,113 (0.06%) | L2 | Rejected-AOC Rejected |
| 4 | L2₹2.3 Cr+₹13,113 (0.06%)Rejected-AOC | ₹2.3 Cr+₹13,113 (0.06%) | L2 | Rejected-AOC Rejected |
| 5 | L2₹2.3 Cr+₹13,113 (0.06%)Rejected-AOC C O NIRANJAN DAS SARUPETA BARPETA ASSAM 781318 | SARUPETA | BARPETA | ASSAM | 781318 | ₹2.3 Cr+₹13,113 (0.06%) | L2 | Rejected-AOC Rejected |
Tender Value
₹2.6 Cr
EMD Value
₹5.2 L
Closing Date
17 Oct 2023, 2:00 pmClosed
Chief Engineer (Roads), PWRD, Assam
O/o the Chief Engineer Roads, PWRD, Assam, Chandmari, Guwahati, 781003.
MMNPPNA_23_24_08 (i) Construction of cover drain from Raju Sonar house Aziz Ali house at ward No-2.( Ch-0.00 m to Ch-670.00 m) (ii) Construction of cover drain leading from Lt Kamal Moulick house to Bimal saha Grocery shop via Shymapalli at ward
2023_PWD_32684_7
CE/DEV/TB/08/2023-24/14
Open Tender
Civil Works
Item Rate
270 days
Barpeta Road MB
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,190
₹5.2 L
Yes
O/o the Chief Engineer Roads, PWRD, Assam
15 May 2024
27 Sept 2023
17 Oct 2023
27 Sept 2023
17 Oct 2023
10 Oct 2023
27 Sept 2023 - 9 Oct 2023
9 Oct 2023
Amount
(i) Construction of cover drain from Raju Sonar house Aziz Ali house at ward No-2. (From Ch 0.00 M to 670.00 M) Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary soil Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 PCC Grade M 20 Nominial mix (1:2:4)
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Direction and Place Identification signs upto 0.9 sqm size board A Retro-reflectorised Traffic Signs (ii) Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Tehnical Specification Clause 1701.
(ii) Construction of cover drain leading from Lt Kamal Moulick house to Bimal saha Grocery shop via Shymapalli at ward No -7 (from Ch 0.00 M to 732.00 M) Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary soil Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 PCC Grade M 20 Nominial mix (1:2:4)
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Direction and Place Identification signs upto 0.9 sqm size board A Retro-reflectorised Traffic Signs (ii) Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Tehnical Specification Clause 1701.
(iii) Construction of Road with Rcc cover Drain(Nort Side) in Barpeta Road Vegetable Market at ward no-9. (from Ch 0.00 M to 453.00 M (A) By mix in place Method -Construction of granular sub base by providing well graded material, spreading in uniform layers with motor grader on prepare surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification clause 401. (ii) For Grading Material (Gr-II)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. A) By Manual Means Using stone screening Type-B 11.2 mm for Gr.III
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 complete including carriage. (i) Including Edge Restrain / Edge Block
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm equilateral triangle
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 800mm x 600mm rectangular
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
RCC Drain Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary soil Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 PCC Grade M 20 Nominial mix (1:2:4)
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
GUPTA HARDWARE PRIVATE LIMITED
kamalchgoyary
JINTU DAS
Uttam Karmakar
UGPB Construction
TEKLO BORO BASUMATARY
Dewarshi Das
BHUPEN DAIMARY
CAPITAL FOOD SUPPLY
BISWADEV DAS
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .