Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹17.2 L+₹1.0 L (6.38%)Rejected-Finance | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹18.0 L+₹1.8 L (10.9%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹18.0 L+₹1.8 L (11.0%)Rejected-Finance | L4 | Rejected-Finance NOT A LOWEST BID | |
| 5 | L5₹18.7 L+₹2.5 L (15.7%)Rejected-Finance | L5 | Rejected-Finance NOT A LOWEST BID |
Tender Value
₹29.8 L
EMD Value
₹59,540
Closing Date
5 Oct 2021, 6:00 pmClosed
GE MH AND RH KIRKEE
GE MH RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR REWIRING OF OTM MARRIED ACCOMODATION INCL REPAIR REPLACEMENT OF ELECTRIC ENERGY METER CEILING FAN EXHUST FAN WALL FAN GEYSER SOLAR WATER HEATER IN INSP ORG UNDER GE MH AND RH KIRKEE
2021_MES_473935_1
8238/E8
Open Tender
Civil Works
Item Rate
270 days
KIRKEE AND AUNDH
AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE MH AND RH KIRKEE
₹59,540
Yes
12 Oct 2021
8 Sept 2021
7 Oct 2021
8 Sept 2021
5 Oct 2021
22 Sept 2021
8 Sept 2021 - 15 Sept 2021
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit and making good disturbed surfaces of walls, floors etc all as directed.
M&L for point wiring complete with 1.5 Sqmm 1100 volts grade single core FRLS PVC insulated unsheathed cable with multi stranded copper conductor drawn through and including PVC casing & capping of suitable size on walls/ ceiling etc and including provn of 1.5 sqmm PVC insulated Multistranded copper cable as earth continuity conductor connected to common earth dolly including 1.22 mm thick pressed steel terminal boxes of suitable thickness, 3mm thick laminated sheet cover to house switch/regulators etc for all as specified and directed for One fan/light /bell point controlled by one switch/bell push
All as per item No 2 above but for One switch socket outlet 5 Amps on independent board
All as per item No 2 above but for One socket outlet 5 Amps on the same board
All as per Item No 2 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 1.5 sqmm PVC insulated copper cable as earth continuity conductor for one switch socket outlet 15 Amps on independent board all as directed.
All as per Item No 2 here-in- before but with 4 Sqmm PVC insulated multistranded copper conductor with 2.5 sqmm cable as earth continuity conductor for Power Socket on independent board all as directed.
M&L for point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor drawn through non metallic rigid PVC conduit and accessories in surface of walls/ceilings/concealed in wall including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including 1.22 mm thick pressed steel terminal boxes of suitable thickness, 3 mm thick laminated sheet cover to house switch/regulators etc all as specified and directed for One fan/light /bell point controlled by one switch/bell push
All as per item No 7 above but for One switch socket outlet 5 Amps on independent board
All as per item No 7 above but for One socket outlet7 Amps on the same board
All as per Item No 7 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 1.5 sqmm PVC insulated copper cable as earth continuity conductor for one switch socket outlet 15 Amps on independent board all as directed.
All as per Item No 7 here-in- before but with 4 Sqmm PVC insulated multistranded copper conductor with 2.5 sqmm cable as earth continuity conductor for power Socket on independent board on the existing/new PVC surface conduit all as directed.
Supply and fix in repairs / replacement switch piano type one way 6 Amps all as specified and directed.
Supply and fix in repairs / replacement switch piano type 16 Amps i all as specified and directed
Supply and fix in repairs / replacement Bell push, flush type, 6 Amp all as specified and directed.
Supply and fix in repairs / replacement switch piano type two way 6 Amps all as specified and directed.
Supply and fix in repairs / replacement Bell push, Modular type, 6 Amp all as specified and directed.
Supply and fix in repairs / replacement socket outlet 2 in1,3 pin 5 Amps all as specified and directed.
Supply and fix in repairs / replacement socket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type all as specified and directed.
Supply and fix in repairs / replacement switch socket combination 2 in 1, 3 pin, 5 Amps all as specified and directed.
Supply and fix in replacement modular switch 1 way 6A 1 module complete all as specified and directed.
Supply and fix in replacement modular switch 2 way 6A 1 module complete all as specified and directed.
Supply and fix in replacement modular socket 6A 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in replacement modular socket 6A /16A 2/3 pin combined 2module complete all as specified and directed.
Supply and fix in replacement modular fan regulator,120 watt - 2 module complete all as specified and directed.
Supply and Fixing Modular white cover plate with frame 1module complete all as specified and directed.
Supply and Fixing Modular white cover plate with frame 2 module complete all as specified and directed.
Supply and Fixing Modular white cover plate with frame 3 module complete all as specified and directed.
supply and Fixing Modular white cover plate with frame 4 module complete all as specified and directed.
Supply and Fixing Modular white cover plate with frame 6 module complete all as specified and directed.
Supply and Fixing Modular white cover plate with frame 8 module complete all as specified and directed.
Supply and Fixing modular metal flush Box 1/2 module complete including taking down rusted metal box and necessary platering work and finish with existing wall paint all as specified and directed.
Supply and Fixing replacement modular metal flush Box 3 module complete including taking down rusted metal box and necessary platering work and finish with existing wall paint all as specified and directed.
Supply and Fixing replacement modular metal flush Box 4 module complete including taking down rusted metal box and necessary platering work and finish with existing wall paint all as specified and directed.
Supply and Fixing replacement modular metal flush Box 6 /8 module complete including taking down rusted metal box and necessary platering work and finish with existing wall paint all as specified and directed.
Supply and fix ceiling rose surface bakelite with three terminals complete including taking down rusted metal box and necessary platering work and finish with existing wall paint all as specified and directed.
Supply and fixing replacement of RCCB four pole 30 mA 63 A all as specified and directed by Engr-in-chrge. Make: Hager/L & T
Supply and Replace electric bell Ding Dong, AC 230 volts complete all as specified and directed.
S & F sheet metal enclosures for double door distribution board factory made duly painted 4 way SPN and neutral 240 v with 200 amps rated bus bar , suitable for fixing MCB /Isolators all as specified ( Make Cat No. DSDMTNVODI 08 of Standard or its equivalent in Havells /Indoasian )
S & F sheet metal enclosures for double door distribution board factory made duly painted 8 way SPN and neutral 240 v with 200 amps rated bus bar , suitable for fixing MCB /Isolators all as specified Make: Hager/L & T/legrand
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC Conduit of suitable size including 4.0 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge..Note: Two single core cable, earth wire and PVC conduit shall be measured as one length.
Taking down old submain wiring and M&L for sub main wiring with two single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 v.olt grade drawn into PVC conduit of suitable size including 6 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing all as specified and directed by Engr-in-Charge. Note: Two single core cable, earth wire and PVC conduit shall be measured as one length.
Taking down carefully old unserviceable existing Aluminium strip of size 25 mm x 3 mm and Supply & fix Aluminium strip 25 mm x 3 mm complete with saddles and fixing screws for fitting the strip all as specified and directed.
Taking down carefully old unserviceable existing Galvanised iron strip 32 mm x 6 mm and Supply & fix Galvanised iron strip 32 mm x 6 mm complete with saddles and fixing screws for fitting the strip all as specified and directed.
S & F fan regulator suitable for 1200/1400 mm ceiling fan (Electronic step type) complete all as specified and directed
M&L for Air terminations single pointed Aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangements on roof including taking down old all as directed.
M&L for Air terminations single pointed copper rod 12 mm dia and 300 mm long with necessary fixing arrangements on roof all as directed.
Supply and fix test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. head screw including taking down old all as spcified and directed by Engr- in - Charge..
M &L for repair, replacement of damaged, rusted cast iron/pressed steel terminal boxes on inside wall S & F Cast iron/pressed steel terminal boxes 60 mm deep 75 mm x 75 mm Square size and cutting sheet for mounting removed existing and new switches, sockets, fan regulator, etc with 3 mm thick plastic laminated sheet cover making surface good with cement plaster or POP all as specified and directed by Engr-in-charge.
M &L for repair, replacement of damaged, rusted cast iron/pressed steel terminal boxes on inside wall S & F Cast iron/pressed steel terminal boxes 60 mm deep 100 mm x 100 mm Square size and cutting sheet for mounting removed existing and new switches, sockets, fan regulator, etc with 3 mm thick plastic laminated sheet cover making surface good with cement plaster or POP all as specified and directed by Engr-in-charge.
M &L for repair, replacement of damaged, rusted cast iron/pressed steel terminal boxes on inside wall S & F Cast iron/pressed steel terminal boxes 60 mm deep 150 mm x 75 mm Square size and cutting sheet for mounting removed existing and new switches, sockets, fan regulator, etc with 3 mm thick plastic laminated sheet cover making surface good with cement plaster or POP all as specified and directed by Engr-in-charge.
S & F MCCB 4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacity 125 Amps
M & L for point wiring complete with and including 1.5 Sqmm (nominal area) single core multi stranded copper conductor PVC insulated but unsheathed FRLS cable 1100 volts drawn in to and including stove enamelled steel concealed conduit ISI marked of suitable size including its accessories such as tee, bend, elbow, socket and chiselling in wall complete and also making good the disturbed surfaces of wall/ceiling by cement mortar 1:4 including painting the distrubed wall to match with the existing surfaces and also including 1.5 sqmm PVC insulated and PVC unsheathed single core multistranded copper conductor FRLS cable 1100 V grade as earth wire for housing flame proof socket, regulator, switches etc complete including necessary FLP-WP multiple entry junction box of suitable size , FLP flexible metalic hose conduit and compressing cables with glands of flameproof double compression cable glands brass of suitable size and connecting to earth dolly all as specified and directed for One light , fan point controlled by one no of one way flameproof switch
All as per item No 52 above but for One switch socket outlet 5 Amps on independent board
All as per item No 52 above but for point wiring with 2.5 Sqmm cable for 15 Amp point
S & F Switch flame proof rotary type with termination box in LM6, 16 A, single pole 250 V, complete all as specified and directed.
S & F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 A, 250 V 2 P+Earth complete all as specified and as directed.
M & L for Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore
M&L for taking out point wiring including fittings and fixtures from the concealed conduit and providing point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor drawn through the existing non metallic rigid PVC conduit and accessories concealed in walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including 1.22 mm thick pressed steel terminal boxes of suitable thickness, 3mm thick laminated sheet cover to house switch/regulators etc all as specified and directed for One fan/light /bell point controlled by one switch/bell push
All as per item No 58 above but for One switch socket outlet 5 Amps on independent board
All as per item No 58 above but for One light point controlled by two nos of two way switch
All as per Item No 58 here-in- before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable for switch socket outlet 15 Amps on independent board all as directed.
All as per Item No 58 here-in- before but with 4 Sqmm PVC insulated multistranded copper conductor with 2.5 sqmm cable as earth continuity conductor for Power Socket on independent board on the existing Concealed conduit all as directed.
Taking down old unserviceable fitting and Supply and fixing LED lights fitting 20W, (4 FT long) ,6500k temp 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.as directed by Engr-in-charge. Make: Crompton /Wipro/Philips
Taking down old unserviceable fitting and Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.as directed by Engr-in-charge. Make: Crompton /Wipro/Philips
Taking down unservieable fitting Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. Make: Crompton /Wipro/Philips
Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. all as specified and directed. Make: Crompton /Wipro/Philips
S & F Recess mounting LED ultra modern design light fitting 18 watt, 1 x 1, with efficient LEDs all as specified and directed. Make: Make: crompton cat No: LSDP-09-CDL/Wipro/Philips
Taking down old unserviceable MH high bay light S & F suspended type Industrial LED High bay light 150 W with glass (IP-66) , energy saving, environment friendly & robust open type vertical Highbay/mediumbay LED IP 54 luminaire with high power COB LED as light source, including constant voltage and current LED driver all as directed. (Note: (i) Making arrangement for T & P to fixing of bay light is incluidng quoted rate. Make : :Crompton/C & S/Philips
Taking down conventional light fitting and Supply and fixing energy saving LED Flame proof light fitting 2 x 16/20 W CMRI certified suitable for Gas/Vapour group of IIA & IIB, IP 65 protection necessary screwing, fixing of exisitng iron channel required square box connecting with three core flexible wire all as specified and directed by Engr-in-Charge. Make :Crompton/C & S/Philips
M & L for repair and replacment of Flame proof Fan regulator all as specified and directed. Make: Sudhir or equivalent make of ISI marked
Supply and fix single phase LPRF type kwh meter 5-30 A LCD display with optical port and removing existing unserviceable meter and handed over to MES store yard all as specified and directed. Make: L & T /Havells
Supply and fix Three phase LPRF type kwh meter 10-60 A LCD display with optical port and removing existing unserviceable meter and handed over to MES store yard all as specified and directed. Make: L & T /Havells
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning., .Make L &T /Legrand/Hager
All as per item No 73 above but SP 40 AMP , .Make L &T /Legrand/Hager
All as per item No 73 above but SPN 32 Amps .Make L &T /Legrand/Hager
All as per item No 73 above but SPN40-63 Amps. Make L &T /Legrand/Hager
All as per item No 73 above but TPN 40-100 Amps. Make L &T /Legrand/Hager
Taking down defective vertical V/TPN DB existing at site S & F Vertical TPN DB IP-43 metal door 6 way CRCA Sheet steel, RAL 9003, powder coated provided with insulated vertical phase bus bars, neutral bars with shroud earth bar sticking saddles, cement spill protector color coded interconnecting wire set cable ties blanking plates and circuit identification labels with provision for MCCB As incomer and SP/TP MCBs as outgoings suitable for 4 pole MCCB 125 Amps. (MCCBs and MCB measured separately)Make: Schneider/L & T/Hager
M & L for earthing complete in repairs with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 3.20 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. (Note: (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge.
S & F in repairs thermostats/cutout ISI marked as required at site for geyser of capacity 25/35/50 Ltr of any make all as directed by Engr-in-charge
S & F in repairs of safety valve/high pressure valve ISI marked as per site requirement or all as per directed by Engineer-in-Charge.
S & F in repairs heating element of rating 1/1.5 KW as required at site including rubber washers all as specified and directed by Engr-in-charge..
S & F in repairs heating element of rating 2 KW as required at site including rubber washers all as specified and directed by Engr-in-charge..
S & F in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection all as specified and directed by Engr-in-Charge
S & Fixing in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection all as specified and directed by Engineer-in-charge.
S & Fixing in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge.
M & L for preparation of steel surface and applying of one coat of syntheic enamel paint white including writing of MES Nos with black paint complete to geysers of any capacity or make all as specified and directed by Engineer-in-charge.
M & L for repairs /re-fixing on exiting or new location to storage type electric water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following works mentioned here under againt Ser Nos (a) to (m) at different locations (a) Inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank .b) Examine water tightness of storage tank after cleaning. (c) Carry out operation of all stop cocks, pressure reducing valves etc. to ensures free movement of the working parts. (d) S & F Replacement of the rubber / PVC gasket to ensure water tightness. (m) Checking of safety valve (e) Testing of geysers after repairs.
S & F stop valve , cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore
M & L for rewinding of ceiling fan of 1200/1400 mm sweep of any make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection,capacitor base and testing complete all as specified and directed by Engr-in-Charge. Note: (a) Bearing will be measured and paid separately under relevant item of schedule.
All as per item No. 90 above but of Flame proof Ceiling fan of any size and type
All as per item No. 90 above but of Flame proof exhaust fan of any size and type
All as per item No. 90 above but Exhaust Fan of sweep 275-300 mm
All as per item No. 90 above but Exhaust Fan of sweep 350-450 mm
All as per item No. 90 above but wall mounted/Bracket fan of sweep 350-450 mm
All as per item No. 90 above but Air circulator of sweep 350-450 mm
Supply and fixing ball bearing (DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC
Supply only ball bearing suitable for 275-450 mm exhaust fan complete all as specified and directed Make : SKF/NBC or equivalent
Supply only capacitor 2.5 mfd for ceiling fan all as specified and as directed.
Supply only capacitor 4 mfd for exhaust fan all as specified and as directed
Fixing in repair aluminium strip 25 mm x 3mm complete with saddles and screws for fitting the strip.
Supply & fix four pointed ( centre tip 150mm and side spike 75mm) copper spike lighting arrester heavy duty copper rod opf size 15 mm dia both end screwed for easy fitment and 1.5mtr long and heavy duty copper base plate duly drilled on four corners of size 75mm x 75mm ,with necessary fixing arrangement on Top/side of pole complete including taking down old all as spcified and directed by Engr- in - Charge.
S & F Flampe proof MCB DB for 20 A incoming-1 No, Outgoing 10 Amps MCB 01 No, 6 A MCB -2 Nos (Note: All MCBs are flame proof type, necessary iron angle, fixing materials included in quoted rate)
M & L for repairing, replacment of unserviceable parts of solar water heater of any type after completion of work testing the heater all as specified and directed by Engr-in-Charge
S & F in repair of fountain water tight fitting of 20 W RGB under water light IP 68 luminaire, size 190 mm x 250 mm, SS housing including suitable wiring with submersible cable all as specified and directed by Engr-in-charge.
Taking down old submain wiring and M&L for sub main wiring with 4x6.0 sq. mm + 2x4.0 sq. mm earth wire core multistranded PVC insulated copper conductor FRLS Cable 1100 v.olt grade drawn into PVC casing capping of suitable size including two runs 4 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing all as specified and directed by Engr-in-Charge. Note: Four single core cable, two no s earth wire and PVC casing capping shall be measured as one length .
Labour only for attending genral complaints received through complaint slip with 01 High skilled electrician and 01 Helper for one shifts from 0830 hrs to 1730 hrs for monday to satarday at CQAE residential area, CQA tech area, Gunta Vihar, Manu Vihar,CQAFE tech area, NBC, CQA ME tech area(near Ambedkar chock) Note: - (i) The complaints will be entered in complaint slip by JE E/M MCM. (ii) The complaint slip should be returned to JE E/M on completion of the work with stores consumed. (iv) The complaints will be attended on the same day as assigned. (iii) The details of stores consumed, complaint slip are to be produced during the RAR bills. (v) Tools and minor items like srews, washer, as required for attending the complaints shall be provided by the contractor .
Decarbonizing of indoor MCB / meter box any type removing unserviceable MCCBs, burnt busbars, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter , replacing burnt, damaged bus bar of any size and fixing proper hanging front and rear openings, welding of hinges including welding of brokieng MS sheet using extra sheets replace burnt thimbles with new existing size thimbles replacing with new MCCB & MCBs, powder coating painting with suitable 'U' type gasket to make it dust and vermin proof, providing fancy locks incluidng dismantling the existing connected cables and re-connecting the same cables complete all as specified and directed by Engr -in- charge. Note : (i)MCCBs,indicator lamps,Ammeter, Volt meter, will be measured & paid separately as supply only . (ii) necessary MS sheet and welding incuding sealing the meter with sealing Lead/PVC seal with MES Emblum empossing on it all are inclusive coated rate. (iii) Required size of neutral bus bars including coated rate. (iv) Required size of copper cable for connecting MCBs and meters are including quoted rate.
S & F in reapir meterpanel box indoor type wall mounting of with locking arrangement including powder coating siemens grey shade for size 1200 (w) x 1000 (h) x 250 (d) mm. with the provision of MCB mounting chanels suitavble for mounting four nos three phase meter and one single phase meter for steer case meter all as specified and directed by Engr in charge.
Supply and fix in repairs / replacement switch socket combination 2 in 1, 5 pin, 15 Amps all as specified and directed.
PURVA ELECTRICALS AND ENGINEERS
metro electrical services
AN-ICON Engineering Technologies And Infrastructure Developments Pvt. Ltd
ganesh electricals and airconditioners
SHREE VAIBHAV ELECTRICALS
GRACE CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .