SUPPLY OF HYDRAULICS LAB EQUIPMENTS
2020_DoTE_157640_1
GPTCKDV/128/B2/2020 SUPPLY OF HYDRAULICS LAB
Limited
Laboratory and scientific equipment
Supply
10 days
Chidambaram
REFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹0
Exempted
25 Feb 2020
11 Feb 2020
19 Feb 2020
11 Feb 2020
18 Feb 2020
11 Feb 2020
11 Feb 2020 - 18 Feb 2020
HYDRAULICS LAB EQUIPMENTS:
CLOSED CIRCUIT BERNOULLI’S THEOREM APPARATUS: DESCRIPTION : Circuit Bernoulli’s Theorem Apparatus. SUPPLY TANK : Made up of SS 304 Unit of suitable size provided with piezometer for the measurement of total potential head. SIZE: 300X300X700=63 LITERS VARIABLE CROSS SECTION TRANSPARENT DUCT: A transparent duct made of acrylic and of smooth variable cross section with suitably spaced 0.5mm height replaceable high quality graduated glass tube to measure the pressure head along the duct and a GM flow control valve. MEASURING TANK : Made up of SS 304 Unit of suitable size with an overflow arrangement & provided with a PVC control valve & an elbow. SIZE: 300X300X500 =45 LITERS SUMP TANK : Made up of SS 304 Unit of suitable size for storage of water to circulate through experimental unit. SIZE: 1250X300X300= 112.5LITERS SUPPLY PUMP SET: Supply pump set of 0.5 HP to pump the water from the sump to the unit through proper piping system with a gate valve to control the rate of flow, and connect with a suitable switch. MAIN SWITCH: Single phase main switch. SERVICES REQUIRED: Single phase power supply 200/220V & water to fill up the sump tank. Note: 1. All pipings should be GI pipe 2. Operation manual with experiment procedure should be provided. 3. Performance test should be done at our premises and test report should satisfy the performance requirement of the equipment
CLOSED CIRCUIT VENTURIMETER APPARATUS: DESCRIPTION : VENTURIMETER TEST RIG. PIPING SYSTEM : Two G.I. pipe lines of size 20 & 25mm fitted with MS tank provided with individual gate valves & Distribution chamber with isolation cocks to facilitate individual experiment on individual venturimeter. DIFFERENTIAL HEAD MEASUREMENT :1 meter manometer with mercury.. MEASURING TANK : Made up of SS 304Unit of suitable size with an overflow arrangement & provided with a PVC control valve & an elbow. SIZE: 400X300X500=60 LITERS SUMP TANK: Made up of SS 304Unit of suitable size for storage of water to circulate through experimental unit. SIZE: 1250X300X400=150 LITERS SUPPLY PUMP SET : Supply pump set of 0.5 HP to pump the water from the sump to the unit through proper piping system with a gate valve to control the rate of flow, and connect with a suitable switch. MAIN SWITCH : Single phase main switch. SERVICES REQUIRED : Single phase power supply 200/220V & water to fill up the sump tank. Note: 1. All pipings should be GI pipe 2. Operation manual with experiment procedure should be provided. 3. Performance test should be done at our premises and test report should satisfy the performance requirement of the equipment
CLOSED CIRCUIT ORIFICEMETER APPARATUS: DESCRIPTION : ORIFICEMETER TEST RIG. PIPING SYSTEM : Two G.I. pipe lines of size 20 & 25mm MS tank fitted with provided with individual gate valves & Distribution chamber with isolation cocks to facilitate individual experiment on individual orifice meter. DIFFERENTIAL HEAD MEASUREMENT: 1 meter manometer with mercury. MEASURING TANK : Made up of SS 304 Unit of suitable size with an overflow arrangement & provided with a PVC control valve & an elbow. SIZE: 400X300X500=60 LITERS SUMP TANK: Made up of SS 304Unit of suitable size for storage of water to circulate through experimental unit. SIZE: 1250X300X400=150 LITERS SUPPLY PUMP SET: Supply pump set of 0.5 HP to pump the water from the sump to the unit through proper piping system with a gate valve to control the rate of flow, and connect with a suitable switch. MAIN SWITCH : Single phase main switch. SERVICES REQUIRED: Single phase power supply 200/220V & water to fill up the sump tank. Note: 1. All pipings should be GI pipe 2. Operation manual with experiment procedure should be provided. 3. Performance test should be done at our premises and test report should satisfy the performance requirement of the equipment
CLOSED CIRCUIT ORIFICE TANK APPARATUS DESCRIPTION: For determination of co- efficient of discharge (cd) SUPPLY TANK: Made up of SS 304 Unit of suitable size with a fixture arrangement to mount 2 replaceable orifice. SIZE: 300X300X1000=90 LITERS ORIFICE: Two orifices made of gunmetal which is 1.Circular of 10mm diameter 2.circular of 15mm diameter MEASURING TANK: Made up of SS 304 Unit of suitable size with an overflow arrangement & provided with a PVC control valve & an elbow. SIZE: 400X300X400=48 LITER SUMP TANK: Made up of SS 304 Unit of suitable size for storage of water to circulate through experimental unit. SIZE: 1500X300X400= 180LITERS SUPPLY PUMP SET: Supply pump set of 0.5 HP to pump the water from the sump to the unit through proper piping system with a gate valve to control the rate of flow, and connect with a suitable switch. MAIN SWITCH: Single phase power supply 200/220V & water to fill up the sump tank. Single phase main switch. SERVICES REQUIRED: Single phase power supply 200/220V & water to fill up the sump tank. Note: 1. All pipings should be GI pipe 2. Operation manual with experiment procedure should be provided. 3. Performance test should be done at our premises and test report should satisfy the performance requirement of the equipment
CLOSED CIRCUIT MOUTHPIECE TANK APPARATUS DESCRIPTION: For determination of co- efficient of discharge (cd), SUPPLY TANK: Made up of SS 304 Unit of suitable size with a fixture arrangement to mount 2 replaceable orifice. SIZE: 300X300X1000=90 LITERS MEASURING TANK: Made up of SS 304Unit of suitable size with an overflow arrangement & provided with a PVC control valve & an elbow. SIZE: 400X300X400=48 LITER SUMP TANK: Made up of SS 304 Unit of suitable size for storage of water to circulate through experimental unit. SIZE: 1500X300X400= 180LITERS SUPPLY PUMP SET: Supply pump set of 0.5 HP to pump the water from the sump to the unit through proper piping system with a gate valve to control the rate of flow, and connect with a suitable switch. MAIN SWITCH :Single phase main switch SERVICES REQUIRED : Single phase power supply 200/220V & water to fill up the sump tank. Note: 1. All pipings should be GI pipe 2. Operation manual with experiment procedure should be provided. 3. Performance test should be done at our premises and test report should satisfy the performance requirement of the equipment
CLOSED CIRCUIT PIPE FRICTION APPARATUS: DESCRIPTION Pipe Friction Apparatus. PIPEING SYSTEM : Two G.I. pipe lines of size 15 & 20 mm having a set of individual gate valve & Distribution chamber with isolated cocks to facilitate individual experiments on piping system. FRICTIONAL HEAD LOSS : ½ meter manometer with mercury. MEASURING TANK Made up of SS 304 Unit of suitable size with an overflow arrangement & provided with a PVC control valve & an elbow with piezometer. SIZE: 400X300X500=60 LITERS SUMP TANK: Made up of SS 304 Unit of suitable size for storage of water to circulate through experimental unit. SIZE: 1250X300X400=150 LITERS SUPPLY PUMP SET: Supply pump set of 0.5 HP to pump the water from the sump to the unit through proper piping system with a gate valve to control the rate of flow, and connect with a suitable switch MAIN SWITCH : Single phase main switch. SERVICES REQUIRED: Single phase power supply 200/220V & water to fill up the sump tank. Note: 1. All pipings should be GI pipe 2. Operation manual with experiment procedure should be provided. 3. Performance test should be done at our premises and test report should satisfy the performance requirement of the equipment
CLOSED CIRCUIT FRANCIS TURBINE TEST RIG- 1HP CAPACITY: FRANCIS TURBINE: Type : Inward flow reaction Turbine Capacity :1HP Rated speed :1000 rpm Discharge capacity : 750 LPM Supply Head : 10 meters Buckets : Gun Metal Vanes (Aerofoil Blade shaped) LOADING: Loading : Rope Brake Material : Cast Iron Drum Size : 200 MM Diameter SUPPLY PUMP SET: Size : 3”x2 ½” Discharge : 750 Liters / Minute Total Head : 20 Meters Motor capacity : 5 HP FLOW MEASUREMENT : Venturimeter Material : C.I. body PRESSURE MEASUREMENT P: ressure Gauges RPM INDICATOR : DIGITAL SUMP TANK :Material of Construction: Made up of SS 304 SIZE: 1250X700X600=525 LITERS SERVICE REQUIRED : Electrical supply – 5 HP, 3 phase, 440 Volts, 50 Hz, Ac supply Note: 1. All pipings should be GI pipe 2. Operation manual with experiment procedure should be provided. 3. Performance test should be done at our premises and test report should satisfy the performance requirement of the equipment
TDK EQUIPMENTS
SRI JAI EQUIPMENTS
RANGA ENTERPRISES
JAY INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .