Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC AT BARIMAL PO HATIBARI PS SUKINDA DIST JAJPUR PIN 755018 | JAJAPUR | ODISHA | 755018 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹28.4 L+₹2.3 L (8.62%)Rejected-Finance AT BRAJARAJPUR PO INS CHILKA DISTT KHORDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹28.6 L+₹2.5 L (9.47%)Rejected-Finance AT AMRITPUR PO NB CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹51,000
Closing Date
22 Nov 2021, 6:00 pmClosed
Garrison Engineer Chilka
Garrison Engineer Chilka PO INS Chilka Distt Khordha Odisha 752037
ADDITION / ALTERATION AND SPECIAL REPAIRS TO SHIP MAST AND PARADE GROUND AND PROVN OF AXIS ROAD FOR EXISTING RO PLANT AT INS CHILKA UNDER GE CHILKA
2021_MES_483191_1
GE/CHL/8749 OF 2021-22
Open Tender
Civil Works
Item Rate
182 days
Garrison Engineer Chilka
MES Enlisted Contractor of Class D category a i
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Chilka
₹51,000
Yes
3 Dec 2021
22 Oct 2021
29 Nov 2021
22 Oct 2021
22 Nov 2021
8 Nov 2021
22 Oct 2021 - 30 Oct 2021
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavating over areas not exceeding 1.5 m depth and getting out as in soft/ loose soill complete all as specified and as directed.
Excavating in post holes (or similar holes) , each not exceeding 0.5 cum , getting out, returning, filling in and removing surplus soil to a distance not exceeding 50 m in soft/oose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L for natural river sand as cushioning of cables including spreading and punning down complete all as specified and as directed. Note :- Punned thickness shall be measured for payment purpose
Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance exceeding 50 m but not exceeding 100 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Moorum or red bajri filling in floors pavings/ roads, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering to required level and gradient complete all as specified and as directed.
M&L for broken stone hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for providing precast cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate louvres and jallies 25mm thick (measured solid) including all moudlings but excluding frame , set in cement mortar 1:4 complete all as specified and as directed.
M&L cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in lintels upto 1.5m clear span,chajjas, roof kerbs or mud stops, rounded or chamfered on edges and other similar work complete all as specified and as directed.
M&L RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L cement concrete1:2:4 type B-1 using 20 mm graded stone aggregate in coping , benching of manholes etc and including necessary use and waste of form work complete all as specified and as directed.
M&L RCC 1:2:4 type B-1 using 20 mm graded stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns etc complete all as specified and as directed.
M&L RCC 1:12:4 type B-1 using 20 mm graded stone aggregate in columns, pillars, piers, posts and struts etc complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
M&L for brick work with fly ash bricks, straight or curved on plain exceeding 6m means radius built in cement mortar 1:6 complete all as specified and as directed.
Supply and laying fly ash brick of size 200x100x80mm locallly available as protection of cable in trenches complete all as specified and as directed.
M&L for Walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6, complete all as specified and as directed.
Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges, rough finish surfaces of concrete complete all as specifed and as directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft & raft beams, side & soffits of foundation & plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete flat complete all as specified and as directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns, and stanchions rough finished surfaces of concrete square, rectangular or polygonal complete all as specified and as directed.
Cutting existing steel tubing 80 or 100 mm bore of pipe for alterations or additions complete all as specified and as directed. Note:-Each cut measured as one unit.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not packing) removing of serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L 18 to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and as directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L 100 mm thick cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate, surface finished even and fair complete all as specified and as directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of flooring, surface finished even rough to receive further finishes complete all as specified and directed
M&L for 75 mm thick cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as sub base of flooring complete all as specified and directed
M&L for chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigment over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and as directed.
Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L 15 mm thick rendering on brickwork or concrete surfaces in cement mortar 1:4,surface finished even and fair complete all as specified and as directed.
M&L for applying two coats of weather proof acrylic emulsion paint exterior grade (100% acrylic) of silver steak shade of asian paint over a coat of primer including preperation of newly plastered external surfaces of walls of any description over 10 cm width or girth etc on column/ pillars, RCC chajja and facia complete all as specified and as directed.
M&L applying three coat of white wash on wall including preparation of newly plastered surfaces of wall complete all as specified and as directed.
M&L for applying two coat of white wash on walls including preparation of old decorated plastered surfaces of wall complete all as specified and as directed.
M&L applying one coats of synthetic enamel paint including preperation of old painted steel surfaces of any description , not otherwise described over 10cm width or girth complete all as specified and as directed.
M&L applying two coats of synthetic enamel paint on iron and steel work of any description over one coat of red oxide primer including preperation of surfaces complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling and setting aside for reuse within 50 m of steel poles or struts, any size complete all as specified and directed
Fixing only 80 or 100 mm bore old galvanised iron steel tubing and connections in new or old position (Walls, ceiling, floors, etc) complete all as specified and as directed.
S&F 80 mm bore galvanised iron tubes, 'medium grade' with all fittings such as bends, elbow. reducer, socket etc and fixed complete to walls and ceilings or laid in floor complete all as specified and as directed.
S&F 32 mm bore galvanised iron tubes, 'medium grade' with all fittings such as bends, elbow. reducer, socket etc and fixed complete to walls and ceilings or laid in floor complete all as specified and as directed.
M&L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting etc not exceeding 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for providing and fixing stainless steel tube (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc of required size on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.
S&F stainless steel hand rail ball ( Grade 304) 50mm dia on top of stainless steel tube and fixing arrangements complete all as specified and as directed.
S&F stainless steel handrail chain 6 mm dia ( Grade 304) fixed with the hook to stainless steel tube and fixing arrangements complete all as specified and as directed.
M&L Mild steel TMT bar 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for column hooking end and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M&L Mild steel TMT bar 6 to 8 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for column hooking end and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M&L Mild steel TMT bar 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M&L for 40 mm dia bore galvanised iron light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and as directed. Make:- Tata/ Jindal/ Prakash Surya.
M&L 10 mm thick rendering in cement mortar 1:3 on brick work or concrete surfaces , surface finished even and fair complete all as specified and as directed.
M&L Cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in foundation filling etc to make good disturbed surfaces base of Garden light complete all as specified and as directed.
M&L for reinforced concrete pipes class NP-3, laid and jointed complete with collar of 450 mm dia complete all as specified and as directed.
M&L soling (or sub base) 200mm thick with broken boulders or quarried stone, interstices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and as directed. Note:- Spread thicknees is to be measured.
M&L for 100 mm thick PCC 1:3:6, type C-2 using 40 mm graded stone aggregate as sub base of floor or hard standing or in path, surface finished rough to receive further finishes complete all as specified and as directed.
M&L for 150 mm thick PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in floor or hard standing or in path, surface finished even and fair complete all as specified and as directed.
M&L forming construction (Dummy) joints 65 mm deepx10 mm wide filled with sealing compound, Grade 'A' complete all as specified and as directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering. doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) Fe-410w Gde-250 quality A and hanging also fastening and fixing completeall as specified and as directed.
Taking down carefully copper/ aluminium point wiring for light, fan, socket or power point complete with fittings such as switches, fan regulators, light fittings, tube light fittings, bracket light fittings and ceilling rose, holders etc including making good the disturbed surface of walls, complete all as specified and as directed.
M&L for point wiring with PVC FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5 sqmm drawn through in including PVC casing & caping (ISI Marked) not less than 20mm wide with pressed steel concealed box duly covered with 3 mm thick laminated sheets for mounting switches,sockets and other accessories with and including 1.5 sqmm copper conductor FRLS cable for earth continuity conductor of green colour for one light point/ fan point/ exhaust fan/ one 5/6 Amp socket outlet controlled by one 5/6 Amps one way switch complete all as specified and as directed.
All as per item No 61 above but, one socket outlet, three pin, 5/6 Amp on the same board with other switches complete all as specified and as directed.
All as per item No. 61 here-in-before but for 15/16Amp socket out let, independent with 2.5 sqmm copper cable of PVC FRLS insulated, unsheathed, multi stranded and 2.5 sqmm copper conductor cable FRLS as earth continuity conductor of green colour complete all as specified and as directed.
S&F switch socket combination 2 pin & 3 pin 5 Amp, 230 volt, multipurpose, complete all as specified and as directed.
S&F switch socket combination 5 in 1 type, 3 pin 5 / 15 Amp, 230 volt, multipurpose, complete all as specified and as directed.
Taking down old unserviceable MCB DBs with MCBs any type by unscrewing from wall or ceiling and making good the disturbed surface to match with the existing complete all as specified and as directed.
S&F factory made sheet metal enclosure for DBs double door (fixed flush to the wall), SPN, 240 volt, 4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 sqmm copper PVC sheathed stranded cable for earth continuity and suitable for housing MCB’s complete all as specified and as directed. Make:- C&S Electric Ltd /Standard/Havells
S&F MCB 6 to 32 Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified and as directed. Make:- C&S Electric Ltd/Standard/Havells.
S&F MCB 40 Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, complete all as specified and as directed. Make:- C&S Electric Ltd/Standard/Havells.
Supply, laying, jointing and testing XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 6 sqmm 2 core including necessary cable lugs, glands, insulation tape etc including taking out existing unserviceable cable complete all as specified and as directed. Make:- Paragon/Gloster/Havells
S&F in replacement of Garden light 25 watt LED CORAL (Opal), IP-65 new generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun alluminium landscape luminaire with high power LEDs as light source including 40 mm dia galvanised iron pipe having 2.0 M length with suitable size of nuts, bolts , washers etc complete all as specified and as directed. Make :- Havells Model No. CORALPT25WLED757PSYMTOPC or equivalent in Phillips/Crompton Greaves/Bajaj as approved.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-2009, connected to earthing with DBs all as specified including excavation and earth work in any type of soil, PCC 1:3:6 type C-1 using 20mm graded stone aggregate in chamber & 40mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slab, reinforced, with 8mm dia TMT bar at 150mm c/c both ways, 15mm dia GI pipe light grade for earth lead protection, 20mm dia GI medium grade pipe for watering , water funnel etc complete all as specified and testing on completion.
M&L for repair to pot holes of any depth, not exceeding 1 Sqm each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc cutting around edges to at least 25mm in depth, making good by applying tack coat @ 5 Kg per 10 Sqm using paving bitumen VG-30, and putting in pre-mixed bitumenous macadam, well rammed and sealed with binder using paving bitumen of grade VG-30 , 9.8 Kg per 10 Sqm blinded with 0.09 cum of stone chipping , 6.3 mm size and again well rammed (including supply of premixed macadam, binder and chipping) complete all as specified and as directed.
M&L for preparing existing black top road surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt including applying evenly a priming/ tack coat with paving bitumen VG-30 grade at 5 kg per 10 Sqm complete all as specified and as directed.
M&L for laying 40mm consolidated compacted thickness of bituminous premix semi-dense asphaltic concrete with 5.5% binder content by using paving bitumen VG-30 grade by weight of total mix, rolled and compacted to required camber and gradient by using hot mix plant and spread with mechanical paver, rolled and compacted to required camber and gradient with 8 to 10 tonne power road roller complete all as specified and directed Note:- If actual design mix comes less than 5.5% binder content then the rate of recovery of bitumen shall be as pe rate in purchase voucher per kg for the purpose of adjustment. However no adjustment shall be made if the binder content is more than 5.5%
M&L for preparation of new/old surfaces of road/pavements and the like 10cm wide and applying 2mm thick (reflective type) resin thermoplastic paint for road marking strips, lines adashes, arrows, letters etc of apporoved colour by fully authomatic thermoplastic paint applicator machine, fitted with profile shoe, glass beads dispenser, propane tank heaters and profile shoe heater etc, driven by the skilled operator complete all as per MORTH specifications and as directed
BHARAT KUMAR BALL
PABITRA MOHAN PARIDA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .