| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC OPP MINI ZOO HADDO SOUTH ANDAMAN 744 102 | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744102 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.1 L+₹23,549 (2.38%)Rejected-AOC B 33 171 PATEL NAGAR GURUDASPUR ROAD PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹10.8 L+₹90,375 (9.14%)Rejected-AOC | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹11.2 L+₹1.3 L (13.0%)Rejected-AOC D K CITY C 42 MINNIEBAY POST BOX NO 340 HPO PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-AOC Not L1 | |
| 5 | L5₹11.8 L+₹1.9 L (19.1%)Rejected-AOC NO 99 IE DG INDUSTRIAL ESTATE DOLLYUNJ POST BOX NO 554 JUNGLIGHAT POST SRI VIJAYA PURAM 744 103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-AOC Not L1 |
Tender Value
Refer Docs
EMD Value
₹31,000
Closing Date
15 Mar 2021, 6:00 pmClosed
GE
BIRCHGUNJ
REPAIR/REPLACEMENT OF INTERNAL WIRING MCBS DISTRIBUTION BOXES FITTING AND CONNECTED ITEMS IN OTMS AT BRICHGUNJ MIL STN AND AIR FORCE STATION UNDER GE BRICHGUNJ
2021_MES_423020_1
8109A GE BG
Open Tender
Civil Works
Item Rate
270 days
BIRCHGUNJ
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE BIRCHGUNJ
₹31,000
Yes
31 Mar 2021
17 Feb 2021
17 Mar 2021
17 Feb 2021
15 Mar 2021
3 Mar 2021
Amount
Taking down carefully, copper/aluminium point wiring (Light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, regulators, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed by Engineer-in-Charge.
Material and labour Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / ceiling etc. and including 1.5 sqmm copper cable FRLS PVC insulated and unsheathed cable 1100 volts as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for the following: -
One light point/Bell point controlled by one switch
One fan point controlled by one switch and one regulator
One 3 pin switch socket outlet point 5 amps on same board with other switches.
One light point controlled by two two way switch.
One 3 pin switch socket outlet point 5 amps on independent board.
Material and labour for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable 1100 volts in PVC casing & caping for 2 in one, 3 pin 5 Amps & 15 Amps multi purpose socket on independent board and existing cast iron or pressed steel terminal box with new laminated sheet top cover 3 mm thick, including PVC insulated & unsheathed copper conductor cable 4 Sqmm FRLS PVC insulated and unsheathed cable 1100 volts size for earth continuity conductor and connected to earth dolly including painting to existing sunken boxes with anticorrosive bituminous paint after thorough cleaning, all as specified and directed.
Material and labour for Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including 20mm dia medium grade rigid non-metallic surface PVC conduit and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for one light point controlled by one one way switch.
All as per item No. 4 here - in - before but for one fan point controlled by one 5 Amps switch
All as per item No. 4 here - in - before but for 3 pin 5 Amps switch socket combination on independent board.
All as per item No. 4 here - in - before but for 5 Amps switch socket point on the same board controlled by one switch.
Material and labour for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable 1100 volts in PVC medium grade conduit for 2 in one, 3 pin 5 Amps & 15 Amps multi-purpose socket on independent board and existing cast iron or pressed steel terminal box with new laminated sheet top cover 3 mm thick, including PVC insulated & unsheathed copper conductor cable 4 Sqmm size FRLS PVC insulated and unsheathed cable 1100 volts for earth continuity conductor and connected to earth dolly including painting to existing sunken boxes with anticorrosive bituminous paint after thorough cleaning, all as specified and directed.
Material and labour for point wiring as per colour coding with 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable 1100 volt drawn through in and including 19 mm thick rigid non-metallic PVC concealed conduit medium quality including new sunken terminal boxes duly epoxy painted and 3mm thick plastic laminated sheet top cover and continuity earth wire PVC insulated copper conductor standard unsheathed of size 1.5sqmm FRLS PVC insulated and unsheathed cable 1100 volts for one light point / bell point controlled by one switch/fan point controlled by one switch through regulator including cutting chases pinning in making good to facings where required and pointing in cement mortar 1:3 ends of edges of landing, steps, cills, sun shades, shelves, lintels, etc and cutting for concealed conduit wiring etc and making good, cutting not exc 10 cm girth in brick wall complete all as specified.
One light point/Bell point controlled by one switch
One fan point controlled by one switch and one regulator
One 3 pin switch socket outlet point 5 amps on same board with other switches.
One light point controlled by two two way switch.
One 3 pin switch socket outlet point 5 amps on independent board.
Material and labour for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable 1100 volts in and including PVC concealed conduit medium quality, for 2 in one 3 pin 5Amps & 15 Amps multi-purpose socket outlet on independent board and cast iron or pressed steel terminal box duly epoxy painted and with new laminated sheet top cover 3 mm thick concealed in wall including PVC insulated & unsheathed copper conductor cable 4 Sqmm size FRLS PVC insulated and unsheathed cable 1100 volts for earth continuity conductor and connected to earth dolly as per existing all as specified and directed by Engineer-in-Charge.
Supply and fix switch piano flush type single pole one way 5 amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix switch socket outlet 3 & 2 pin (mult pin) 5 amps flush/box type, complete all as specified and as dircted by Engineer-in-Charge.
Supply and fix switch socket outlet, 2 in 1, 3 pin 15 and 5 amps, controlled by one switch flush/box type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix lamp holder(angle type) PVC body with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix bell push single phase, 240 Volts, 50 Hz, complete all as specified and as directed by Engineer-In-Charge.
Supply and fix switch piano flush type single pole two way 5 amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge Make:-Anchor/Havells/Bajaj
Supply and fix bell Ding Dong 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge.
Supply and fix Cordless bell 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge.
Supply and fixing Modular switch 1 way 5 A, 1 module all as specified and directed.
Supply and fixing Modular switch 1 way 15 A, 1 module all as specified and directed.
Supply and fixing Modular Bell push 5A, 1 module all as specified and directed.
Supply and fixing modular socket outlet, 2/3 pin combined, 6/15 Amps, 2 module, 230 volts all as specified and directed.
Supply and fixing modular fan step regulator, 230 V, AC, 120W - 2 module
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as specified and as directed by Engineer-in-Charge Make :Indoasan/C&S/Legrand Note:- Incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc...
Supply and fix in repair MCB single pole and neutral, 240 volts, 6 to 32 amps,10KA,230V, B series complete all as specified and as directed by Engineer-in-Charge Make :Indoasan /C&S/Legrand
Supply and fix in repair MCB single pole 240 volts, 5 to 32 amps,10KA,B series ,230v complete all as specified and as directed by Engineer-in-Charge. Make :Indoasan/C&S/Legrand
S & F in repairs Single Pole and Neutral Enclosure with Two Pin Earth Plug and Socket complete with one MCB, SP, 20 Amps, 240 Volts all as specified and as directed. Make :Indoasan/C&S/Legrand
Supply and fix LED mirror light fitting 1 x 10 Watt provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable mirror light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge. Make: Philips Cat part No- BN021LED10S-6500PSU GRSI or Equivalent in Crompton/Havells.
Supply and fix 10 w LED bulk head fitting prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable fitting of any wattage, complete all as specified and directed by Engineer-in-Charge. Make -C&S cat part no- CG 801B10WLED or Equivalent in Crompton/Philips.
Supply and fix ventilating fan suitable for on working of AC 230 V ,50 Hz 200 mm sweep, incl louvers complete all as specified Make: Usha or eqvt in of Khaitan/ Havells. .
Supply and fix ventilating fan Ventil Air DX white suitable for on working of AC 230 V ,50 Hz 250 mm sweep ,incl louvers complete all as specified Make: Usha or eqvt in of Khaitan/ Havells.
Supply and fix Wall mounting fan electric driven single phase230 volts, oscillating type, 400 mm sweep, high quality ABS base with high speed motor and balanced blades and three leafed with 3 core copper cable of suitable size, complete all as per specified. Make Usha or eqvt in of Khaitan/Havells.
Supply and fix exhaust fans electric driven AC single phase 230 volts 300 mm sweep with louvers including grouting and making whole in wall all as specified. Make : Usha or eqvt in of Khaitan/Havells.
Supply and fix exhaust fans electric driven AC single phase 230 volts 380 mm sweep with louvers including grouting and making whole in wall all as specified. Make: Usha or eqvt in of Khaitan/Havells.
Material and labour for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 6 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories, complete including taking down old wiring all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
Supply & Fixing in repair PVC Casing caping of following sizes with accessories like PVC saddles, bend, Tees, Elbow and screws etc.
Supply and replace in repairs fan condenser 2.5 mfd, AC 440 volts, 50 Hz complete all as specified and as directed by Engr-in-Charge. (Make : Universal /KEIL/Havells)
Supply and fix in repairs ceiling fan hanging clamp with bush, locking pin and nut and bolt Including taking down complete all as specified and as directed by Engineer-in-Charge.
Material and labour, earthing complete with galvanize steel earth plate electrode 60 cms x 60 cms x6.00mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4.0mm by means of bolts ,nuts ,check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20 mm bore GI light grade (ISI marked ) with funnel and wire mesh ,including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No, 5 of MES Sch Part-1 (2009), complete all as specified.
Material and labour in repairs Stringing drawing earth continuity wire PVC insulated unsheathed multistranded copper conductor FR/FRLS by opening junction boxes/corner/wall panelling/ fitting/ fixtures etc connecting to common earth point & connecting to earth dolly for following sizes.
(a) 1.5 Sq mm
(b) 4 Sq mm
Supply and fix 1100 Volt grade heavy duty twin core 10 Sq mm of size,(2 core) flat or circular cable PVC tape and over all PVC sheathed as in service connections suspended by insulated hangers not more than 1.00 meter apart including 4 mm dia GI suspension wire and taking down old unserviceable wire of any type and any size complete all as specified.
Taking out and dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the exhaust fan of size 300mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassembling refixing at same/ required location, complete all as specified and as directed by Engr-in-Charge.
All as per item No 44 above but exhaust fan of 400/450mm sweep
Material and labour for preparation of old painted surface of exhaust fan of any sweep complete and painting the same with one coat of synthetic enamel paint of existing colour using brush and rewriting of MES No complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs condenser 4/3.5 mfd, AC 230 volts, 50 Cycles, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs ball bearing suitable for exhaust fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Taking down exhaust fan of any size/sweep from existing position complete with blades from brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unserviceable spare parts etc, and reassembling and refixing in the same position all as specified and as directed by Engr-in-Charge. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Taking down wall mounted fan of any size/sweep from existing position complete with blades from brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unserviceable spare parts etc, and reassembling and refixing in the same position all as specified and as directed by Engr-in-Charge. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Supply and fix ball bearing suitable for wall mounted fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Taking out and the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the wall mounted fan of size 400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassembling complete all as specified and as directed by Engr-in-Charge.
Supply and fix wall mounted fan covering Net
Supply and fix wall mounted fan blade
Supply and fix capacitor 2 mfd for wall fan.
Dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding with new rotor shaft the ceiling fan of size 1200mm/1400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassembling complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement canopy of ceiling fan, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement ceiling fan hanging clamp with bush, locking pin and nut and bolt, complete all as specified and as directed by Engr-in-Charge.
Dismantling and taking down ceiling fan of any size/sweep from existing position complete with blades, down rod and canopy etc and servicing the same properly by cleaning, greasing, oiling replacing the unserviceable spare parts etc, and reassembling and refixing in the same position all as specified and as directed by Engr-in-Charge. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Supply and fix ball bearing suitable for ceiling fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Supply and fix down rod of appropriate size suitable for ceiling fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
KAPOOR AUTOMOBILES
NAVJEEVAN ENTERPRISES
M/S KHUSHICONSTRUCTION
SMS Engineering Corporation
kakolil trade agencies
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .