Loading…
Loading…
Tender Value
₹7.5 Cr
EMD Value
₹15.0 L
Closing Date
15 Sept 2026, 3:30 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
CIVIL
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N crores or V, whichever is lower; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of total contractual payments in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Similar nature of work for this work is "Any Civil Engineering Work".
27 conditions · 2 needing a document upload
Documents to be uploaded only in the website by the Tenderer Following Annexure duly filled and signed are to be uploaded online only prior to Closing of Tender. Original copy of all the documents to be submitted to office within 7 days whenever demanded by the Railway. Otherwise, Railway reserves rights to Reject/Accept such tender/offer without any reference to the tenderer/ tenderers. Annexure are available at Upload/View Document menu in Home Page of IREPS portal for works tender. Annexure Description 1. Annexure-I(a) Details of the Works Completed by the tenderer during the last seven years to be filled & submitted as per Annexure-I(a). 2. Annexure-I(b) Details of contractual payment received by the Tenderer during the last 3 (three) financial years including the current financial year to be filled & submitted in Annexure-I(b).3 Annexure-II Details of Plants and Machinery with the tenderer to be filled & submitted as per Annexure- II. 4. Annexure-III Details of Personnel and Organization of the Tenderer to be filled & submitted as per Annexure-III. 5. Annexure-IV Details of Works Presently on hand of the Tenderer to be filled & submitted as per Annexure- IV. 6. Annexure-V Details regarding Association of Railway Officer(s) with the tenderer to be filled & submitted as per Annexure- V. 7. Annexure-VI List of the Arbitration Cases of the Tenderer during last five years to be filled & submitted as per Annexure-VI. 8. Annexure-VII List of the Court Cases of the Tenderer during last Five years to be filled & submitted in Annexure- VII. 9. Annexure- VIII NEFT MANDATE FORM. All Payments to the agency (including the refund of the Bid Security of the unsuccessful bidder preferably) will be remitted through NEFT. The Tenderer is required to submit Bank details and A/C No. etc. in Annexure- VIII. 10. Annexure-IX GST COMPLAINT INVOICE: To be filled & submitted as per Annexure-IX. 11. Annexure V (A) by each partners of Partnership Firm/ JV/ HUF/ LLP; FORMAT FOR CERTIFICATE TO BE SUBMITTED / UPLOADED BY TENDERER ALONGWITH THE TENDER DOCUMENTS as per Annexure-V (A) of GCC-2022 12. Annexure-XI LETTER OF CREDIT: To be filled & submitted as per Annexure-XI. 13. Annexure-VIA BID SECURITY: Bank Guarantee Bond from any scheduled commercial bank of India to be filled & submitted as per Annexure-VIA. 14. Annexure-VIB Annual Contractual Turnover Data for the Previous 3/4 Years (Contractual Payment only) to be filled & submitted as per Annexure-VIA. 15. Submission of Form VA properly. 16. Annexure-VI of GCC- 2022: TENDERER'S CREDENTIALS (BID CAPACITY) to be submitted as per Annexure-VI of GCC-2022. (This annexure will be applicable, if tenders having advertised value more than Rs 10 crore wherein eligibility criteria includes bid capacity).
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII,IX,XI. Annexure-VI, VI A & VI B of GCC-2022 respectively. These Annexure are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days Otherwise, Railway reserves rights to Reject/Accept such tender/offer without any reference to the tenderer/tenderers.
Demand for Mandate for NEFT is to be uploaded with a scanned copy duly filled in and signed as per annexure no. VIII. This Annexure is available in View Document menu at Home page and is downloadable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Open e-tender for the work of Remaining work of Phase-1 for soft Upgradation of Sabour, Kahalgaon, BAKA & Godda station under Assistant Engineer/ Bhagalpur in the jurisdiction of Senior Divisional Engineer-II/ Eastern Railway, Malda.
98-MLDT-26-27~ER
98-MLDT-26-27
Open
Works - General
12 Months
Maldah, West Bengal
₹0
₹15.0 L
21 Aug 2026
21 Aug 2026
1 Sept 2026
173 items across 6 schedules · ₹8,61,59,306.76 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| Earth work in filling in embankment, trolley refuges, level crossing approaches, platforms etc. with all classification of approved soil done in layer not exceeding 300 mm thick with breaking all size of clods filling of loose pocket and hand ramming as directed by engineer in charge complete in all respect. With Contractor's earth of approved quality and specification obtained from outside Railway Earth with all lead lift as per site condition. | 10 cum | 500.00 | 2,227 | 1,11,350 | |
| 2 | Providing and fixing of precast central drain of factory made by using high performance self compacting concrete of size (PU shape drain T-6-600mm X 600mm). The rate is including all taxes, GST, royalty, lead, lift, descent, ascent, road taxes , transportation etc. (The rate for earth work in excavation paid separately) | Metre | 500.00 | 11,321.55 | 56,60,775 |
| 3 | Providing and fixing Stainless steel drinking railway water booth of specification sheet thickness 3mm, pipe dia 168mm, overall height 1850mm, floor mounted 04 taps (02 normal + 02 divyangjan), weight approx 116 kg, material SS:304, All material ZINDAL and lessure cutting of all parts. | Each | 33.00 | 38,860 | 12,82,380 |
| 4 | Providing and fixing Stainless steel drinking railway water booth jali of specification angle 35x35x5mm, length 5200mm, pipe 50x50x1.6mm, pipe length (1200mm- 14nos, 350mm - 14nos, 400mm- 4nos), weight approx 60kg, material SS 304. | Numbers | 33.00 | 20,100 | 6,63,300 |
| 5 | Supplying and fixing of coloured preferably yellow pu-tactile strips/studs (guiding/warning/positional) having thickness of 6.0 mm and stem width bet 20- 25 mm with fixing of 04 nos directional strip and 36 nos warrning studs or adhesive /screwed / self adhesive with 3 mtr tape, size 300 mm x 6 mm cover upto area per sq mtr 390 nos of studs. Within the area of 300 mm x 30 mm as ground surface indicator for the visually impaired person on the pedestrian pathway as per manufacturer design / specification and as per harmonized guide line and space standard for barrier free built environment for person with disability and elderly person which is completed as per direction of Engineer in site. as per below specification. Make-con aid (durotact/ eminent tactile/decio. | Sqm | 200.00 | 4,730.39 | 9,46,078 |
| 6 | Grouting by EPOXY resin Hardner HY 840 / HY 951 Aradite GY 257 (HUNTSMAN or CICA) all to be mixed by weight in thr ratio (1:2) respective under pressure 2 to 4 Kg/cm2 with the help of pressure grouting machine consisting of prime mover, mixture agitator primer as required for making holes to fit the nozzles etc. The rate includes cost of all materials, consumable, labours, tools and plants scaffolding/ staging with all lead lift etc as directed by engineer in charge. | Kg | 20.00 | 899.85 | 17,997 |
| 7 | Supplying including fitting and fixing 200mm dia electrically welded steel pipes IS medium class 8mm wall thickness ERWMS screwed and socketed pipes including welding of it at the required depth including painting, jointing and lowering complete as per specification. (The item will be operated as per requirement). | Metre | 20.00 | 3,377 | 67,540 |
| 8 | 80 mm roof panel roof panel 80, top and bottom sheet 0.5mm/0.5/mm ,density 40 kg (+/-2)/ m3 , color off white (effective width 1m chargeable width 1.06m) Remarks: Variation in quantity as per site condition. | Sqm | 50.00 | 4,013.5 | 2,00,675 |
| 9 | GRC Panel Tiles with 25mm of thickness, size, pattern, design and shade. The GRC product should be made from 53 Grade white Portland cement manufactured by JK Cement or Birla white, white quartz fine graded sieve Silica sand, Alkali Resistant glass fiber by NEG Japan, Owens corning Saint Gobain or equivalent, superplasticizer manufactured by Sika/Basf/Perma or equivalent and UV Resistant Synthetic inorganic pigments should be used for pigmentation manufactured by Bayferrox Lanxess or equivalent. The GRC casting shall take place with layering methodology using-spray machines. The fixing of GRC should be done using Dry Cladding method onto structural support members i.e. RCC, Brick work or MS Frame work quoted with Red oxide. The fixtures, fasteners and self- tapping screws to be used for drying. The quantity of fasteners or self tapping screws shall be calculated in according to the weight of screens and actual site fixing conditions. If there shall be a requirement of joint filling then Elastomeric exterior grade paintable PU Sealant will be used. For Final finishing of GRC one weather shield exterior grade water based diluted paint coat will be done if required. Vendor shall submit shop drawings of the same, the drawings to be duly approved by the engineer in charge at site. MS Framework if required to be paid extra as per actual. | Sqm | 100.00 | 6,018 | 6,01,800 |
| 10 | GRC Arch and Column of approved size, pattern, design and shade. The GRC product should be made from 53 Grade white Portland cement manufactured by JK Cement or Birla white, white quartz fine graded sieve Silica sand, Alkali Resistant glass fiber by NEG Japan, Owens corning Saint Gobain or equivalent, superplasticizer manufactured by Sika/Basf/Perma or equivalent and UV Resistant Synthetic inorganic pigments should be used for pigmentation manufactured by Bayferrox Lanxess or equivalent. The GRC casting shall take place with layering methodology using-spray machines. The fixing of GRC should be done using Dry Cladding method onto structural support members i.e. RCC, Brick work or MS Frame work quoted with Red oxide. The fixtures, fasteners and self- tapping screws to be used for drying. The quantity of fasteners or self tapping screws shall be calculated in according to the weight of screens and actual site fixing conditions. If there shall be a requirement of joint filling then Elastomeric exterior grade paintable PU Sealant will be used. For Final finishing of GRC one weather shield exterior grade water based diluted paint coat will be done if required. Vendor shall submit shop drawings of the same, the drawings to be duly approved by the engineer in charge at site. MS Framework if required to be paid extra as per actual. | Sqm | 100.00 | 12,390 | 12,39,000 |
| 11 | Drilling bore holes of 200 mm in Hard Rock by DT method as per requirement and instruction of Engineer-in-charge. the rate should include supply of all tools and plants, labour, material, mechanical rig etc. lowering and extracting the drilling equipment with allancillary works. | Metre | 200.00 | 3,948.15 | 7,89,630 |
| 12 | Drilling deep boring for sinking 250mm to 300mm dia tube well by any mechanical method or by reverse circulation method in any kind of soil except rock. Drilling/Boring is to be done as per requirement and instruction of engineer-in-charge for housing the casing pipe. The rate should include supply of all tools and plants, labour, materials, mechanical rig etc. lowering and extracting the drilling equipment?s with all ancillary works to achieve the high yield & safe clean drinking water, casing pipe etc of following depth [ from G.L to 120M below (+/- 10 meter)]. The rate includes the following items: Approx. Qty :- 1 Jobs (One Job) (i)Minimum dia 115 to max. 125mm PVC CASING PIPE PLAIN (ISI Marked) - As per requirement for the purpose. (ii)Minimum dia 115 to max. 125mm PVC CASING PIPE Ribbed Filter (ISI Marked) - As per requirement for the purpose. (iii)Electric cable (ISI Marked) of required length & core up to control panel. (iv)GI Binding WIRE- as per requirement for hanging the pump. (v)Adopter good capacity - 1 Set. (vi)Boring well cap - 1 No. (vii)Submersible pump - minimum 1.5 HP (Crompton Greaves or any similar approved) to give a minimum discharge 4000 litre/hour - 1 set complete. (viii)Control Panel Board - 1 No. (ix)Gravel of required size & specification or as required, approx - 4m3 (x)All other required valve, tee, union, socket, jute, grease, reducers, threading, cutting, fitting complete in all respect. NOTE:- (1)The rate includes boring, sinking, cleaning for a specified period to achieve the high yield & safe clean drinking water free from sand/earth etc & fixing all above & such accessories/materials. Water to be tested from approved laboratory at the own cost of contractor. No extra will paid for testing of water. (2)Payment for this item shall be made only when the discharge after 24 hours continuous running is minimum 4000 litres/hours. 'V' Notch & tank required for testing be made by the contractor. The rate includes the cost of this work also and not extra payment will be made for this. (3)G.I pipes required for connecting pump to supply line shall be paid through Sch. B1. | Numbers | 2.00 | 2,24,550 | 4,49,100 |
| 13 | Supplying, manufacturing fitting and fixing of prefabricated executive BIO-Toilet which includes Bio digester tank made of FRP having thickness 3 mm to 4 mm of size 1200 mm x 350 mm multi chamber having trapezoidal shape of capacity 350 liter. Superstructure of bio toilet shall be made of colour coated MS squre pipe with polish having floor made of aluminum chequered plate. Door and wall shall be made of 30mm thick PPGI PUFF panel and roof shall be made of colour coated galvanized sheet of 0.45 mm thick louvers aluminium fllushing in all corner joints. It shall be consists of European ceramic commode with WDI cistern of two modes 6 & 3 liters push button, stainless steel wash basin, vanity box with mirror, toilet bpaper holder, health faucet, soap dispenser, ISI marked bib cock, wash basin, colour hange, CFL light 8 watt with holder and wiring arrangement complete in all respect having capacity defecations per day | Per Unit | 16.00 | 1,88,800 | 30,20,800 |
| 14 | Supply of one liter Aerobic Bio Media. | Litre | 32.00 | 4,248 | 1,35,936 |
| Schedule total | ₹1,51,86,361 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022ACS11comp..pdf
ATTACHMENT
GCCAcs6.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
FormVA.pdf
ATTACHMENT
FormV.pdf
ATTACHMENT
CheckList_2.pdf
ATTACHMENT
GCC2022ACS-3_20230426_114140.pdf
ATTACHMENT
GCCACS4.pdf
ATTACHMENT
Commercialcompliance.pdf
ATTACHMENT
TechnicalCompliance.pdf
ATTACHMENT
ACS-2toGCC-2022.pdf
ATTACHMENT
GCCACS5.pdf
ATTACHMENT
GCCACS.pdf
ATTACHMENT
FormVIB.pdf
ATTACHMENT
ModifiedTDofHQ-29.08.25.pdf
ATTACHMENT
GCC-2022ACS9.pdf
ATTACHMENT
GCC-2022ACS10.pdf
ATTACHMENT
GCC-2022ACS7.pdf
ATTACHMENT
JPOregardingcablecutting.pdf
ATTACHMENT
BGFormatforBidSecurity.pdf
ATTACHMENT
BankGuaranteeProformaforPG.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].