Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 CrAccepted-AOC | ₹10.4 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹11.0 CrRejected-AOC 1027 SECTOR 21B CHANDIGARH 160022 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160022 | ₹11.0 Cr | L2 | Rejected-AOC OTHER THAN LOWEST |
| 3 | L3₹11.1 CrRejected-AOC 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹11.1 Cr | L3 | Rejected-AOC OTHER THAN LOWEST |
| 4 | L4₹11.2 CrRejected-AOC | ₹11.2 Cr | L4 | Rejected-AOC OTHER THAN LOWEST |
| 5 | L5₹13.2 CrRejected-AOC | ₹13.2 Cr | L5 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
₹10.1 Cr
EMD Value
₹8.3 L
Closing Date
20 Jul 2024, 6:00 pmClosed
CHIEF ENGINEER CHANDIGARH ZONE
CHIEF ENGINEER CHANDIGARH ZONE N ATEA OLD AIRPORT CHOWK CHANDIGARH 160003
CE CHZ CHM T 04 2024 25 CONSTRUCTION OF SINGLE MNS OFFICERS ACCOMODATION AT CHANDIMANDIR
2024_MES_657654_1
CE CHZ/CHM/T-04/2024-25
Open Tender
Civil Works
730 days
CHANDIMANDIR PANCHKULA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (UTILITY ) CHANDIMANDIR
₹8.3 L
Yes
4 Sept 2024
5 Jun 2024
22 Jul 2024
5 Jun 2024
20 Jul 2024
8 Jul 2024
Amount
SCHEDULE 'A' SECTION-I (BUILDING / STRUCTURE WORKS)
Lump sum price worked out by the Contractor for "Buildings/Structure Works " as listed in Sch 'A' Sec I
SCHEDULE 'A' SECTION-II (SITE CLEARANCE, DEVELOPMENT AND EARTH WORKS)
Lump sum price worked out by the Contractor for "Site Clearance , Development And Earth Works " as listed in Sch 'A' Sec II
SCHEDULE 'A'SECTION-III (INTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the Contractor for "Internal Electrification Works" as listed in Sch 'A' Sec III
SCHEDULE 'A' SECTION-IV (INTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for "Internal water supply works" as listed in Sch 'A' Sec IV
SCHEDULE 'A' SECTION-V (SEWAGE DISPOSAL WORKS)
Lump sum price worked out by the Contractor for "Sewage Disposal Works" as listed in Sch 'A' Sec V
SCHEDULE 'A' SECTION-VI (ROAD AND PATH WORKS)
Lump sum price worked out by the Contractor for "Road and Path works " as listed in Sch 'A' Sec VI
SCHEDULE 'A' SECTION-VII (EXTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for "External Water Supply Works" as listed in Sch 'A' Sec VII
SCHEDULE 'A' SECTION-VIII (EXTERNAL ELECTRIC SUPPLY WORKS)
Lump sum price worked out by the Contractor for "External Electric Supply Works" as listed in Sch 'A' Sec VIII
SCHEDULE 'A' SECTION-IX (LIGHTENING PROTECTION WORKS)
Lump sum price worked out by the Contractor for "Lightening Protection Works" as listed in Sch 'A' Sec IX
SCHEDULE 'A' SECTION-X (FIRE FIGHTING WORKS)
Lump sum price worked out by the Contractor for "Fire Fighting Works" as listed in Sch 'A' Sec X
SCHEDULE 'A' SECTION-XI (DEMOLITION/DISMANTLING WORKS)
Lump sum price worked out by the Contractor for "Demolition/Dismantling Works" as listed in Sch 'A' Sec XI
SCHEDULE 'A' SECTION-XII(Misc Items of Works including Soil Investigation Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
INTERNAL ELECTRIC SUPPLY WORKS
Point wiring (using approved colour coding as per IS) with 1100 volts grade, stranded copper conductor 1.5 Sqmm (nominal area), FRLSH,PVC insulated and unsheathed cable IS 694 marked TEC and FIA approved and including PVC concealed conduit(thickness not less than 1.5mm ) of suitable size and its fittings ISI marked PVC junction boxes terminated in sunken/pressed metal flush box for mounting of modular switches/sockets/fan regulators including white cover plate with frame, also including FRLSH PVC insulated unsheathed stranded copper conductor 1.5 Sqmm (nominal area) 1100 volts grade, copper conductor cable as earth continuity conductor to common earth and connected to earth dolly including necessary cutting/chases complete all as specified and directed by Engineer-in-Charge for the following (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) ( the cost of Modular cover plate and metal flush boxes is included in the unit rate quoted for this item) Note :Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost.:-
(a) One light point controlled by one switch or one (Ceiling/ Wall/ Exhaust) fan point controlled by one switch and regulator and one bell point controlled by one bell push
(b) One 3 pin 6 Amps socket outlet on independent board
(c ) One 3 pin 6 Amps socket outlet on same board
All as per item Ser No 25 here-in-above but one light point controlled by two 2 way switches.
Point wiring (using approved colour coding as per IS) with 1100 volts grade, stranded copper conductor 2.5 Sqmm (nominal area), FRLSH,PVC insulated and unsheathed cable IS 694 marked TEC and FIA approved and including PVC concealed conduit(thickness not less than 1.5mm) and of suitable size and its fittings ISI marked PVC junction boxes terminated in sunken/pressed metal flush box for mounting of modular switches/sockets/fan regulators including white cover plate with frame, also including FRLSH PVC insulated unsheathed stranded copper conductor 2.5 Sqmm (nominal area) 1100 volts grade, copper conductor cable as earth continuity conductor to common earth and connected to earth dolly including necessary cutting/chases complete all as specified and directed by Engineer-in-Charge for the following (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) ( the cost of Modular cover plate and metal flush boxes is included in the unit rate quoted for this item) Note :Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost for one 3 pin 5/15 Amp socket outlet.
Sub-main wiring with 2 single core FRLSH insulated and unsheathed cable with stranded copper conductor of 4.0 Sq mm drawing into & including heavy grade PVC Concealed conduit ISI marked of suitable size with all accessories and one additional 1 run of wire of 4.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles,including necessary cutting/chases complete all as specified and directed. Note: (i) Three runs each of one RM of 4.0 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose. (ii) Work to be executed from SPN DB to AC point.
Sub-main wiring with 2 single core FRLSH insulated and unsheathed cable with stranded copper conductor of 6.0 Sq mm drawing into & including heavy grade PVC Concealed conduit ISI marked of suitable size with all accessories and one additional 1 run of wire of 6.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles,including necessary cutting/chases complete all as specified and directed. Note: (i) Three runs each of one RM of 6.0 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose. (ii) work to be executed from main TPN DB to SPN DB.
Modular Blank plate 1 module suitable for modular switch board complete all as specified and as directed
Energy saving LED light fitting, 1 x20 watt, 230 volts, decorative ultra slim linear LED lighting fixture with extruded ploycarbonate, enviormental friendly, energy efficient ready to use pack, with electronic driver and with best quality diffuser high lumen output, 2.5 KV voltage surge protection, PF0.98, THD<10% suitable for surface/ pendant mounting complete with all accessories including and connecting of with twin core of PVCinsulated 0.75 Sqmm copper conductor cable complete all as specified.
Sheet metal enclosure MCB DB, 6 ways TPN, 240 volts,IP-54 protection, double door type grouting in wall in CM, flush mounted complete with 200 Amp rated bus bar complete all as specified and as directed.
Sheet metal enclosure MCB DB, 12 ways SPN, 240 volts,IP-43 protection, double door type grouting in wall in CM, flush mounted complete with 240V Amp rated bus bar complete all as specified and as directed.
Sheet metal enclosure MCB DB, 4 ways SPN, 240 volts,IP-43 protection, double door type grouting in wall in CM, flush mounted complete with 200 Amp rated bus bar complete all as specified and as directed.
MCB SP, 230 volt , 50 Hz, 6 to 32 A, 10 KA , "B" series complete all as specified and directed.
MCB SPN, 'B' Curve as incommer, 220 volt , 50 Hzs, 32 Amps, 10 KA ,complete all as specified and directed.
MCB TPN, 'B' Curve as incommer, 440 volt , 50 Hzs, 63 Amps, 10 KA , complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed by Engineer-in-charge.complete all as specified and directed.
RCBO- A Type (SPN-2 M) 32 Amps 30mA (In accordance with IS 12640-2 & ICE 61009-1) 240C, 50 Hz, with 10 kvA short circuit capacity, RCBO is designed for use in domestic, commercial and industrial distribution systems at the most downstream circuit for ensuring protection from leakage current, short circuit & over load to be user for a particular circuit. In normal unse, it is safe to use and free of threat to user as well as to environment complete all as specified and directed.
Arc Fault Detection Device (AFDD) 32A, rated voltage 240V AC, 50 Hz frequency, residual operating current 30mA, double pole, SPN, three module, Short circuit capacity 10kA, Type A, residual making and breaking capacity 500A, Electrical/Mechanical Endurance 10000 operations (made in India), Terminal capacity 25sqmm protection class IP-20, Protection class with enclosure IP-40, DIN Rail mounting method, Vibration Resistance 3g, Shock Resistance 40mm free fall complete all as specified and as directed.
Telephone socket complete all as specified and as directed.
TV socket complete all as specified and as directed.
Ceiling fan 5 star rated with BLDC technology AC single phase 240 Volt 50 Hz of size 1200 mm sweep complete in white colour having service value more than or equal to 6 with canopy, hanging rod and all accessories incl nuts,bolts, clamps etc including making connections with twisted 3 core PVC insulated unsheathed flexible cord of 0.75 sqmm copper conductor from ceiling rose to ceiling fan, complete all as specified and directed
Exhaust fan 300 mm sweep made of sturdy Engineering metal body, heavy duty, Single phase AC 230/240V, with energy efficient motor, pre lubricated double ball bearing, speed 900 rpm complete with louvers for wall mounting incl grouting,making hole in the wall and holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core from ceiling rose to exhaust fan incl cutting of hole of required size for fixing of the exhaust fan , complete all as specified and directed.
Exhaust fan 300 mm sweep made of sturdy Engineering plastic body, heavy duty, Single phase AC 230/240V, with energy efficient motor, pre lubricated double ball bearing, speed 900 rpm complete with louvers for wall mounting incl grouting,making hole in the wall and holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core from ceiling rose to exhaust fan incl cutting of hole of required size for fixing of the exhaust fan complete all as specified and directed
LED bulb 10 watt 230 volts AC 50 Hz Retrofit B22 base for lamp holder complete all as specified and directed.
Surface mounted wall Mirror LED light Compact & sturdy 10 watt,2 feet, LED decorative fixture with anti glare polycarbonate diffuser, multi purpose lighting solution & applications .all accessories & fixtures, internally prewired and connecting by providing copper flexible wire 23/.0076 mm twin core upto fitting, complete in all respects,
Surface mounted wall Mirror LED light Compact & sturdy 5 watt LED decorative fixture with anti glare polycarbonate diffuser, multi purpose lighting solution & applications .all accessories & fixtures, internally prewired and connecting by providing copper flexible wire 23/.0076 mm twin core upto fitting, complete in all respects,
Rigid non-metallic PVC conduit of 25 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. all as specified & directed.
Energy saving new generation energy saving and enviormental friendly long life LED building security light 1x 35 watts made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 32mm bore light grade GI pipe bend to shape, including MS clamp of size of required size including necessary modification at the upper end of GI pipe bracket as per pipe size of light fitting, making necessary holes and connected items like nut, bolts, washer etc. and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specfied and directed
Earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed. Note :- GI Strip more than 7.5 mtr will be measured and paid separately
Taking out existing ceiling fan any size,dismantling blades and removing fan and blades to store all specified and directed by Engr-in-charge
Taking out existing electric meter by disconnecting electric connection and removing electric meters to store and refixing with necessary electric connection of the same after completion of electric work all specified and directed by Engr-in-charge
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire burried in ground complete all as secified and as directed
Electric water heater (Geyser) storage type of capacity 25 Itr BEE 5 star rated with element of capacity 2KW, ABS body, metal tank with glass lined coating multiple heating option, shock safe plug puf insulation, incoly glass coated anode rod/ copper heating element with ISI mark, adjustable knob for temp setting with minimum & high working pressure, multifunctional safety value, & whirl/swirl flow technology, thermostat electronic type, complete including superior quality copper connection pipe heavy duty 15 mm dia 450 mm long, brass adopter for water connection with nickel coated ISI marked with fastener, nut bolt, washers duly grouted, giving shape to hole as suitable and plastering including testing complete all as specified and directed by Engineer-in-Charge complete all as specified and directed. Note:- (i) Portable residual current device is deemed to be included in overall cost. (16 Amp, 30mA). (ii) Water pipe line upto inlet of Geyser shall be part of internal water supply schedule.
ROAD AND PATH
80mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, walkway, parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand & filling the joints after laying complete all as specified and as directed.
SUMMER APPLIANCES
Supply and installation of Desert cooler electric driven (single phase) with outer body made of PGI (Plain Galvanised Iron) sheet not less than 1.20 mm thickness for fixed part,thickness of PGI (Plain Galvanised Iron) sheet for shutter not less than 0.80 mm thickness,front grill made of PGI (Plain Galvanised Iron) sheet with minimum weight 2.80 kgs,overall outer size not less than 66 cm X 66 cm X 99 cm (Height) ,copper wounded fan motor having nominal air flow capacity of 4000 cum per hour ,capacity of water storage tank not less than 80 ltr and submersible pump for required flow of water complete all as specified and directed.
Supply, installation, testing and commissiong of Water cooler partially stainless steel electric driven single phase having approx storage capacity of 40 ltrs and nominal cooling capacity of 20 ltrs per hour complete all as specified and directed.
Supply, installation, testing and commissionig Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250V copper wound with output voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 2 KVA.complete all as specified and directed.
EXTERNAL WATER SUPPLY
DI/GI pipe fittings for spigot and socketed/flanged joint suitable upto 150 mm bore such as bends(any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc),Tee pieces single branch. Y junction, double branch, cross (all sockets and spigot ) collars, caps and plugs,tail pieces with one end flange(integrally cast) and one end socket, complete suitable for any size of pipe and push on flexible rubber tyton joints/flange joints complete all as specified and directed
Sluice valve, 150 mm bore, cast iron body, having brass spindle with iron wheel at top, class PN 1.6, with flanged ends, drilled suitably, complete with joints and including necessary joints by means of bolts, nuts washers and rubber gaskets, conformig to IS 14846-2000 complete all as specified and directed.
Sluice valve, 80 mm bore, cast iron body, having brass spindle with iron wheel at top, class PN 1.6, with flanged ends, drilled suitably, complete with joints and including necessary joints by means of bolts, nuts washers and rubber gaskets, conformig to IS 14846-2000 complete all as specified and directed.
Construction of brick masonary valve pit of size 1000 mm x 1000mm x 900 mm (Internal size) thickness of walls shall be 23cm in brick work in CM 1:6, internally plastered 15 mm thick in CM (1:6) and externally plastered in CM (1:4), 15cm thick PCC 1:4:8 type D-2 having 15cm offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 on the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40 mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
Cutting road/Hard standing/ path up to 45cm width and 1 mtr depth and making good by using PCC type C2 (1:3:6) using 40 mm graded stone aggregate and finishing complete including earth work all as specified and directed.
EXTERNAL ELECTRIC SUPPLY WORKS
Supply, installation, commissioning and testing Manufacturer or OEM (original equipment manufacture) Diesel Engine Driven Generating Set capable of delivering 40 KVA or nearest higher rating 415 Volts (AC 3 Phase ,1500RPM ,4 wire system of supply) , 50 Hz at power factor 0.8 minimum. The DG Set shall consist of a diesel engine flexible coupling coupled directly to matching alternator and mounted on metalastic foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure (the complete set conforming to and test certified as per CPCB norms IV or latest and as specified) all as specified, directed complete with AMF control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet return oil arrangement, suitable exhaust pipe complete and shall comprise and including the following :-
(A)Engine (Prime Mover) : The diesel engine should be totally enclosed, compression ignition, water cooled (radiator cooled) turbo charged suitable for Power generation application having minimum of suitable BHP capacity to drive the 40 KVA alternator at 1500 rpm under NTP condition confirming to BS 649, complete with all interconnecting piping and the following standard accessories. Suitable fly wheel, Flexible coupling. Air Cleaner. Radiator heavy duty type,Cooling fan, Water circulating pump.Corrosion resistor, PT Fuel pump, Electronic governing control (EGC),Fuel filter,Fuel shut down solenoid (24V DC, stop solenoid, Lubricating Oil filter, Oil cooler, By pass filter, Silencer,Starter,cold starting kit,antivibration pad.
(B) ALTERNATOR:- AC alternator copper wound, self excited, self regulated, self ven 40 KVA PF 0.8 1500 RPM insulation class 'H'. Enclosure IP 23 complete with AVR with + 0.5% voltage regulation, directly coupled to and match the above engine and alternator confirming to IS-4722, permissible over load 10% for 1 hour in 12 hour operation complete all as per IS-13364.
(C) METALLASTIC : Anti-vibration pads for mounting engine, alternator assembly on the base frame/plate.
(D) BASE PLATE : Base Plate shall be made out of structural steel as per manufacturer's recommended design/specifications.
(E) ACOUSTIC ENCLOSURE : Provision of an integral type approved/certified acoustic enclosure weather proof, water proof and corrosion free, as per latest CPCB norms, for the DG Sets to restrict the noise level to 75 db at one meter distance and temp rise within canopy shall not exceed 50 - 70 degree C. It shall be made of 14 SWG CRCA MS Sheet with powder coated finish on outside and provided with non igniting fire retardant foam as acoustic material. There shall be four hinged doors out of which one shall be with a glass window. The base shall be of ISMB section all as directed and shall include as under:-
(F) BATTERY : (i) Suitable capacity battery maintenance free as per manufacturer recommendation (ii) Battery charging alternator with inbuilt regulator and suitable size copper leads
(G)Silencer shall be absorption type, non resistance, residential and exhaust pipe covered with asbestos rope of suitable size extending to about 2 meters outside the acoustic enclosures.
(ii) Internal wiring with PVC copper conductor cables, IS - 694 marked, FRLS in conduit and fluorescent lamp fittings.
(iii) Fuel tank of 8 hours capacity made out of 14 SWG CRCA MS sheet, duly powder coated and provided with float, gauge and fuel float switch - 01 Set (iv) Foundation for DG Set shall be as per design of OEM and shall be provided within overall cost quoted.
Material & Labour for cutting of existing hard standing/road up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed.
Taking out existing serviceable LT panel of capacity 250 amp after disconnecting all incoming and outgoing connections including taking out carefully cable size of 150/70/16 sq mm 3.5 core approx 3x30 mtr and refixing same LT panel at new location within 25 mtr radius and refixing all cables with suitable joints and lugs,PCC foundation for LT panel and necessary modification in existing panel and busbar complete all as specified and directed Note: Exavation & cable of any size will be measured and paid separately.
Supply installiation, testing and commissioning factory made,outdoor type, floor mounted, main LT panel board, cubicle type totally enclosed outer edge made out of 3.15 mm thick CRCA sheet and inner compartments of 2 mm thick sheet metal enclosed with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50HZ system , with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circuit cable entry holes at bottom only with suitable PVC/rubber/wooden brushes to prevant ingrass of water/vermin etc,inside the enclosure,required nos of holes to be fixed with chromium plate brass cable glands for cable entry and exit complete with neccesary internal wiring with standard copper conductor FRLS wire of adequate size,duly powder coated internally and externally of approved colour with pcc foundation (1:2:4) and aluminium busbar 400 amp ( 01 set comprising 4 nos strip) for 3 phase and neutral mounted on epoxy insulator,CTs, Ammeter, votmeter,indicator lamp including following accesories. INCOMING:- (i) MCCB 125 Amps, 4 pole,25KA = 01 No (Main Incoming for 16 Offrs Block) OUTGOING:- (ii) MCCB 32 Amps, 4 pole 16 KA =5 Nos (01 No for each floor and 01 spare) (ii) MCB SPN 20A =1 Nos (For Stilt) (iii) Digital Voltmeter-01 No (iv) Digital Ammeter-01 No (v) Indicator Lamp-01 Set (vi) CT-600/5
Supply installiation, testing and commissioning factory made,outdoor type, floor mounted, main LT panel board, cubicle type totally enclosed outer edge made out of 3.15 mm thick CRCA sheet and inner compartments of 2 mm thick sheet metel enclosed with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50HZ system , with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circuit cable entry holes at bottom only with suitable PVC/rubber/wooden brushes to prevant ingrass of water/vermin etc,inside the enclouser,required nos of holes to be fixed with choromium plate brass cable glands for cable entry and exit complete with neccesary internal wiring with standard copper conductor FRLS wire of adequate size,duly powder coated internally and externally of approved colour with pcc foundation (1:2:4) and aluminium busbar 1000 amp ( 01 set comprising 4 nos strip) for 3 phase and neutral mounted on epoxy insulator,CTs, Ammeter, votmeter,indicator lamp including following accesories. INCOMING:- (At Existing Power House) (i) ACB 4 Pole,415 v,Manual adjustable type Drawout type with microprocessor release of capacity 630 Amps 50KA = 01 No OUTGOING:- (ii) MCCB 160 Amps, 4 pole 25 KA =01 Nos(for LT panel for 16 Offrs Block) (ii) MCCB 250 Amp ,4pole 25 KA =02 Nos (for LT panel for 21 Offrs Blcok) (iii) Digital Voltmeter-01 No (iv) Digital Ammeter-01 No (v) Indicator Lamp-01 Set (vi) CT-600/5
Supply installiation, testing and commissioning factory made,outdoor type, floor mounted, main LT panel board, cubicle type totally enclosed outer edge made out of 3.15 mm thick CRCA sheet and inner compartments of 2 mm thick sheet metel enclosed with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50HZ system , with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circuit cable entry holes at bottom only with suitable PVC/rubber/wooden brushes to prevant ingrass of water/vermin etc,inside the enclouser,required nos of holes to be fixed with choromium plate brass cable glands for cable entry and exit complete with neccesary internal wiring with standard copper conductor FRLS wire of adequate size,duly powder coated internally and externally of approved colour with pcc foundation (1:2:4) and aluminium busbar 200 amp ( 01 set comprising 4 nos strip) for 3 phase and neutral mounted on epoxy insulator,CTs, Ammeter, votmeter,indicator lamp including following accesories. INCOMING:- (i) MCCB 125 Amps, 4 pole,25 KA = 01 No (Main Incoming for 16 Offrs Block) OUTGOING:- (ii) MCCB 32 Amps, 4 pole 16 KA =5 Nos (01 No for each floor and 01 spare) (ii) MCB SPN 20A =1 Nos (For Stilt)(iii) Digital Voltmeter-01 No (iv) Digital Ammeter-01 No (v) Indicator Lamp-01 Set (vi) CT-600/5
Supply installiation, testing and commissioning factory made,outdoor type, floor mounted, main LT panel board, cubicle type totally enclosed outer edge made out of 3.15 thick CRCA sheet and inner compartments of 2 mm thick sheet metel enclosed with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50HZ system , with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circuit cable entry holes at bottom only with suitable PVC/rubber/wooden brushes to prevant ingrass of water/vermin etc,inside the enclouser,required nos of holes to be fixed with choromium plate brass cable glands for cable entry and exit complete with neccesary internal wiring with standard copper conductor FRLS wire of adequate size,duly powder coated internally and externally of approved colour with pcc foundation (1:2:4) and aluminium busbar 200 Amp ( 01 set comprising 4 nos strip) for 3 phase and neutral mounted on epoxy insulator,CTs, Ammeter, votmeter,indicator lamp including following accesories. INCOMING:- (i) MCCB 100 Amps, 4 pole,16 KA = 01 No (Main Incoming ) (DG set panel) OUTGOING:- (i) MCCB 40 Amps, 4 pole 16 KA =3 Nos (For Lift & 01 No spare) (ii) MCCB 32 Amps, 4 pole 16 KA =3 Nos (For fire fighting & 01 No spare) (iii) Spare slot for Changeover Switch of capacity 63 Amps (iv) Digital Voltmeter-01 No (v) Digital Ammeter-01 No (vi) Indicator Lamp-01 Set (vii) CT-600/5
Supply installiation, testing and commissioning factory made Feeder Pillar outdoor type made out of 3.15mm thick incorporated with 3 phase 4 wire system aluminum bushar 200 amp, insulator with one no of incoming 32 amp TPN 4 pole , 415 volt , fixed on angle iron frame grouted in the PCC 1:2:4 upto 30 cm duly painted with powder coated paint and angle iron frame with two coat of synthetic enamel paint over a coat of red oxide primer paint complete all specified and directed . (This item shall be provided for each block fire fighting equipment)
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 240 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 185 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 150 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 70 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 50 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 25 sq. mm, 4 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 16 sq. mm, 2 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 10 sq. mm, 2 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
LED street light fitting 35 watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistance IP 65/66 protection all as specified and directed. Note:- GI pipe 40mm dia 1.2 mtr long, 02 Nos MS clamps of suitable size with fastener, copper cable of 1.5 sqmm for electric connection from ceiling rose to light fitting shall be deemed to be included in the item.
Post top lantern complete for 40 Watts LED,IP 65 protection with impact and corrosion resistant,360 degree indirect light complete with driver and fittings all as specified and directed
Aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish 3.5 mtrs long compatible for all post top range including earth work, PCC foundation as per design of manufacturer and all fittings complete all as specified and directed.
Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE cable of size 70 Sqmm complete all as specified.
Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE cable of size 150 Sqmm complete all as specified.
Earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed. Note :- GI Strip more than 7.5 mtr will be measured and paid separately
Supply and fixing Galvanised iron strip 25mm x 3mm burried in ground complete all as secified and as directed
Supply and fixing Galvanised iron tubes, `light grade', 40 mm bore, with all fittings for earth strip protection complete all as specified and directed.
SEWAGE DISPOSAL WORKS
Providing at site, lowering , laying, aligning, fixing in position and jointing in trenches at all level/ depths, ISI marked Asbestos cement pipes 150 mm dia class 1 (Mazza process) pipes for sewer and drainage application as per IS 6908-1991 (amended upto date with AC coupler joints sealed with rubber gaskets (EPDM/SBR) as per IS 5382 complete, including cost of all materials, labour, jointing, water sectional hydro testing (including cost and covenyance of water to site for testing) etc laid in trenches on concrete bed to level /gradient ,jointing with appropriate class fittings as per manufacturer's instructions including jointing accessories and fittings complete, all as specified and directed by Engineer-in-charge.
Providing at site, lowering , laying, aligning, fixing in position and jointing in trenches at all level/ depths, ISI marked Asbestos cement pipes 200 mm dia class 1 (Mazza process) pipes for sewer and drainage application as per IS 6908-1991 (amended upto date with AC coupler joints sealed with rubber gaskets (EPDM/SBR) as per IS 5382 complete, including cost of all materials, labour, jointing, water sectional hydro testing (including cost and covenyance of water to site for testing) etc laid in trenches on concrete bed to level /gradient ,jointing with appropriate class fittings as per manufacturer's instructions including jointing accessories and fittings complete, all as specified and directed by Engineer-in-charge
Precast cement concrete Grade M 30 manhole cover SFRC (steel fibre reinforced cover) factory made including suitable precast RCC frame as per manufacturer's instructions, heavy duty as approved by GE as in cover slabs of size 600 x 1200 x 100 mm thick set in cement mortar 1:4 and similar articles complete as per site requirement, all as specified and directed by Engineer-in-charge.
Precast cement concrete Grade M 30 manhole cover SFRC (steel fibre reinforced cover) factory made including suitable precast RCC frame as per manufacturer's instructions, heavy duty as approved by GE as in cover slabs of size 600 x 1500 x 100 mm thick set in cement mortar 1:4 and similar articles complete as per site requirement, all as specified and directed by Engineer-in-charge.
FIRE FIGHTING WORKS
Supply and fixing 63 mm dia instantaneous pattern branch short stainless steel 304 pipe, minimum 12.5 mm dia nozzle conforming to IS903, suitable for inter connection to hose pipe coupling complete all as specified and directed.
Supply, fixing and testing of Booster pumps for 440v, 3 phase 50 HZ confirming to IS-12469:1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for 900 LPM discharge,30M head and pressure 3.5 kg/cm2 with suitable star delta starter complete all as specified and directed. Note- Each block shall have two pumps ( 01 working + 01 standby)
Supply and fixing stop valve screwed complete of 25 mm dia all as specified and directed
Supply and fixing air release valve of size 25 mm dia complete all as specified and directed
Supply and fixing 2 way fire brigade complete all as specified and directed
Supply and fix addressable fire alam control panel complying with BS EN 54 single loop panel including 12V/7AH maintenance free battery for operation of panel complete all as specified and directed
Supply and fix addressable manual call point break glass type with alam LED. It should be interlinked with central control panel complete all as specified and directed.
Supply and fix addressable loop powered sounder complete all as specified and directed.
Sub main wiring with 2 single core FRLSH insulated and unsheathed cable with stranded copper conductor of 1.5 sqmm drawing into & including heavy grade steel concealed conduit ISI marked of suitable size with all accessories and one additional 1 run of wire of 1.5 sqmm but green in colour for earth DBs and boxes with proper thimbles, including necessary cutting/chases complete all as specified and directed. Note:- (i) Three runs each of one RM of 1.5 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Supply and fixing CO2 type fire extinguisher MS body with indicator filled with 4.5 kg capacity, filled with discharge hose and horn and squeeze grip type valve with initial charge. The extinguisher will be as per BIS: 15683 bearing ISI mark, vessel should be PESO, EN, PED approved and CE marked with all accessories, complete all as specified and directed.
Supply and fixing ABC stored pressure type fire extinguisher filled with 6 kg capacity bearing for fighting ABC class of fire.The extinguisher will be as BIS:15683 bearing ISI mark,vessel should be EN, PED approved and CE marked complete with all accessories, complete all as specified and directed.
Supply and fixing water stored pressure type fire extingusher,filled with 9 litre capacity minimum sheet metal thickness 1.5 mm fire extingusers . The extinguisher will be as per BIS: 15683 bearing ISI mark, vessel should be EN, PED approved and CE marked complete with all accessories, complete all as specified and directed.
Supply and fixing Mechanical foam stored pressure type filled with 9 litre capacity fire extingusher will be manufactured strictly as per BIS: 15683 bearing ISI mark and vessel should be EN, PED approved complete all as specified and as directed.
Supply and fixing fire bucket with stand complete all as specified and directed.
Supply and fixing linear pneumatic heat detection tube (UL approved) in MTR ,complete all as specified and directed.
Supply and fix Pressure switch 5 bar, complete all as specified and directed.
Supply and fix end of line adaptor with pressure gauge, complete all as specified and directed.
Supply and fix end of line plug, complete all as specified and directed.
Supply and fix T-connector, complete all as specified and directed.
Supply,installation,testing & commissioning of control input module used for monitoring two contacts and signals to the fire controller, status of monitored contacts and wiring to the contacts can monitor a single normally closed contact (for flow switch,tamper switch, conventional gas detectors).Approved by EN54/VDS/LPCB, complete all as specified and directed.
Earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade earth plate surrounded by alternate layer of coal dust and common solt 15 cm thik each layer all as per electrical plate and connected to Panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long.
Supply and fixing Aluminium strip 25mm x 3mm on lift body/motor to earth test point ternimal box with saddles and screws for fixing complete all as secified and as directed
Note:(i) Complete schedule of fire fighting shall be carried out as per recommendation of CFEES. (ii) Complete scheme shall be tested in presence of rep of user, rep of CWE & Engr-in-charge before issue of completion certificate. Only on successful operation of scheme completion shall be issued. (iii) Complete scheme shall be checked for successful operation at an interval of 6 months till completion of defect liability period. Cost of these checks shall be included in overall cost quoted. (iv) Refilling of portable type Fire extinguisher shall be carried out every six month till completion of defect liability period within overall cost quoted. (v) Complete scheme shall be executed by an agency which has minimum three years experience in executing similar works. (vi) Any leftout item required for successful operation of scheme is deemed to be included in overall rates quoted. (vii) Layout of complete scheme shall be prepared before execution and shall be got approved from GE. (viii) Escape Lighting and exit signage as per recommendation of CFEES shall be provided within overall cost included.
LIFTS
Design supply, install testing & commissioning 8 passengers lift, speed 1.0 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS- 14665, suitable to serve G + 04 upper floors with AC Variable Voltage & Variable Frequency drive(VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel framed glass doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (one each in car & near Ground floor landing door),standard panel suitable for lift complete all as specified and as directed, and including followings:- 1. Car dimensions 1100 mm wide x 1300mm deep x 2200mm high 2. Door opening min 800mm wide x 2000mm high 3. Handrail Round in Stainless Steel finish provided on rear wall of car 4. ACVVVF closed loop drive 5. Alarm button in car operating panel with battery back-up 6. Automatic operation for car fan 7. Adjustable door open time 8. Anti-nuisance (empty car) 9. Anti-nuisance (car call cancellation at direction reversal) 10. Blower fan in car for ventilation 11. Braille on push buttons
12. Car call cancellation by double pressing floor button in car operation panel 13. Door open and door close buttons in car operating panel 14. Door closing retries 15. Door nudging 16. Emergency light 17. Full load by-pass 18. Home landing 19. Infra-red screen for car door 20. Intercom 21.Jammed landing operating panel call button by-pass
22. Motor overheat protection 23. Overload function with audio-visual indication in car operating panel 24. Phase failure and phase reversal protection 25. Automatic rescue device in case of power failure 26. Attendant control 27. Car arrival chime on car 28. 4.3'' LCD display in landing operating panel on All Floors 29. Fireman control 30. Fireman emergency return 31. Independent operation (car VIP function) 32. Parking operation (key switch in landing operating panel) on main floor 33. Voice announcement unit in English language in car 34. RCC Socle for car and counter weight buffers. Note:(i) "Pre-commissioning of lift shall be carried out by "State Lift Inspector "within overall cost quoted. In case of non availability of " State Lift Inspector" rep of AO shall be carryout "pre-commissioning test within overall cost quoted. (ii) Lift shall be operated by contractor before completion for a period of one month only on successful operation for one month, lift shall be taken over. Complete expenditure on account shall be borne by contractor. (iii) All cable shall be fire survival type (iv) M&O of Lifts shall be carried out for the period of two years which shall be paid under separate schedule. Lift operator shall also be responsible for RESCUE in case Lift gts stuck.
Design supply, install testing & commissioning 8 passengers lift, speed 1.0 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS- 14665, suitable to serve G + 04 upper floors with AC Variable Voltage & Variable Frequency drive(VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel framed glass doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (one each in car & near Ground floor landing door),standard panel suitable for lift complete all as specified and as directed, and including followings:- 1. Car dimensions 1100 mm wide x 1300mm deep x 2200mm high 2. Door opening min 800mm wide x 2000mm high 3. Handrail Round in Stainless Steel finish provided on rear wall of car 4. ACVVVF closed loop drive 5. Alarm button in car operating panel with battery back-up 6. Automatic operation for car fan 7. Adjustable door open time 8. Anti-nuisance (empty car) 9. Anti-nuisance (car call cancellation at direction reversal) 10. Blower fan in car for ventilation 11. Braille on push buttons
12. Car call cancellation by double pressing floor button in car operation panel 13. Door open and door close buttons in car operating panel 14. Door closing retries 15. Door nudging 16. Emergency light 17. Full load by-pass 18. Home landing 19. Infra-red screen for car door 20. Intercom 21.Jammed landing operating panel call button by-pass
22. Motor overheat protection 23. Overload function with audio-visual indication in car operating panel 24. Phase failure and phase reversal protection 25. Automatic rescue device in case of power failure 26. Attendant control 27. Car arrival chime on car 28. 4.3'' LCD display in landing operating panel on All Floors 29. Fireman control 30. Fireman emergency return 31. Independent operation (car VIP function) 32. Parking operation (key switch in landing operating panel) on main floor 33. Voice announcement unit in English language in car 34. RCC Socle for car and counter weight buffers. Note:(i) "Pre-commissioning of lift shall be carried out by "State Lift Inspector "within overall cost quoted. In case of non availability of " State Lift Inspector" rep of AO shall be carryout "pre-commissioning test within overall cost quoted. (ii) Lift shall be operated by contractor before completion for a period of one month only on successful operation for one month, lift shall be taken over. Complete expenditure on account shall be borne by contractor. (iii) All cable shall be fire survival type (iv) M&O of Lifts shall be carried out for the period of two years which shall be paid under separate schedule. Lift operator shall also be responsible for RESCUE in case Lift gts stuck.
Earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade earth plate surrounded by alternate layer of coal dust and common solt 15 cm thik each layer all as per electrical plate and connected to Panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long.
Supply and fixing Aluminium strip 25mm x 3mm on lift body/motor to earth test point ternimal box with saddles and screws for fixing complete all as secified and as directed
DEMOLITION / DISMANTLING
Disconnecting the power supply and taking down carefully by unscrewing from boards fitting and fixture such as DBs, junction Box, panel of any size complete with all MCCBs, MCBs,etc and removing from site all specified and directed by Engr-in-charge
Taking down old unserviseble sub main wiring any size and removing from site all specified and directed by Engr-in-charge
Taking down of existing service cable 4 sqmm to 16 sqmm and removing from site all specified and directed by Engr-in-charge
Taking out existing Security light fitting any size and removing from site all specified and directed by Engr-in-charge
Taking out old MCCB any size and removing from site all specified and directed by Engr-in-charge
Taking out Old LT XLPE insulated, galvanized steel strip armourred cable,cross sectional area 35/50 sq mm and removing from site all specified and directed by Engr-in-charge
Taking down up or down steel tubing and connection 100mm bore including all fittings and removing complete all as specified and directed by Engineer-in-Charge.
SOIL INVESTIGATION
Mobilization of necessary eqpt and man power to the project site and dismantling of the same of completion of Field work from the site
Provision of two bore hole of 150mm dia in any type of soil upto max 35 mtr or upto refusal (N=100) whichever meet first conduction standard penetration test as per IS 2131-1981 (reaffirmed - 2016). Test shall be made at not more than 1.5 mtr interval or on change of strata whichever is less. (One no. of Borehole at each building site)
Provision of two bore hole of 150mm dia in any type of soil upto max 10 mtr or upto refusal (N=100) whichever meet first conduction standard penetration test as per IS 2131-1981 (reaffirmed - 2016). Test shall be made at not more than 1.5 mtr interval or on change of strata whichever is less. (One no. of Borehole at each building site)
Conducting following lab test on bore collected soil samples. (i) Direct/Triaxial Shear Test. (ii) Grain distribution curves & pattern in bore holes. (iii) Bulk desity. (iv) Natural Moisture content. (v) Dry Density. (vi) Water table. (vii) Specific gravity. (ix) Atterberg limit. (x) Hydrometer analysis. (xi) Liquid & plastic limit. (xii) Swelling Index).
MANNING AND OPERATION OF LIFTS:-
Manning & Operation of Lift electrically operated Microprocessor controlled complete with power driven automatic stainless steel (SS) sliding doors and having SS car enclosure of size, 8 passenger at a spped of 1.0m/sec to serve upto 5&6 floors (G+4&5 Floors) including automatic rescue device after completion of work. The defect if any shall be attended or intimated immediately to concerned incharge. ) (1 lift attendant per building per shift of 8 hours)(Total 02 lift attendants) Notes: (i) The Lift operator employed should be ITI and should have Minimum 4 year experience of lift operator. (ii) Lift operator shall be deployed for one shift per day. Timing of shift shall be as decided by GE.Lift operator shall also be responsible for RESCUE in case Lift gets stuck.
Description all as per item no 161 here in above but after completion of item no 161 above.Work order shall be placed separately.
Description all as per item no 161 here in above but after completion of item no 162 above.Work order shall be placed separately.
Note: For the purpose of arriving at contract amount, the amount of credit Rs 5109686.00 shall be deducted from the total amount arrived.
Total Rs.
H.P. CONSTRUCTION CO.
A.S. CONSTRUCTION CO.
SAR AGENCIES
Saru Enterprises Pvt Ltd
DES RAJ AND SONS BUILDERS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid