Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.5 L+₹1.3 L (4.44%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹31.1 L+₹2.8 L (9.79%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹31.5 L+₹3.2 L (11.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹31.6 L+₹3.3 L (11.6%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
27 Dec 2023, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REP MAINT OF INTERNAL WIRING INCLUDING SUB MAIN WIRING SPN TPN DBS BUILDING SECURITY LIGHTS TO CERTAIN OFFRS JCOS OR MD AND OTM ACCN AT SI LINES AND REP MAINT OF CEILING FANS EXHAUST FAN WALL MOUNTED FAN AND MISC EM WORKS AT SI LINES UNDER GE BHOPAL
2023_MES_629990_1
8236/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹99,800
Yes
15 Mar 2024
25 Nov 2023
29 Dec 2023
25 Nov 2023
27 Dec 2023
15 Dec 2023
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Labour only for attending day to day complaints for repairing of internal electrification work such as unserviceable tube lights, bulk head fittings, recess lights, mirror lights, building security lights, LED bulbs, switches, sockets, lamp holder, fan regulator, bell push, ceiling rose, plug top, MCBs and any other minor defects required for its smooth functioning at SI Line Military Station by deputing skilled and qualified electrician alongwith helper at any time of the day as per site requirement complete all as specified and directed. Note:- (i) Complaints shall be attended and rectified within 24 hrs after intimation or receiving reciept of complaint slip otherwise penalty of Rs 250.00 per day will be levied on contractor. (ii) Complaints will be reported on daily basis with complaint register. (iii) Other minor items such as insulating tape, screws, small pieces of electrical cables PVC insulated copper multistranded conductor of size 2.5 Sqmm three core upto length of 1.5 m etc as required to attend the complaint is included in quoted rates.
Taking down existing point wiring of any type with PVC conduit with fittings/PVC casing-capping or any other type for light, fan, power point including switch, socket, ceiling rose, etc and making good disturbed surface of wall/ceiling to match with existing surface complete all as specified and directed.
M&L for concealed point wiring for one light/fan/exhaust fan controlled by one switch with and including single core PVC insulated unsheathed flexible conductor FRLS cable of 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium grade PVC conduit as per IS 9537 (Part-III): 1983 of not less than 20mm nominal size including modular/ non modular type all accessories/fitting/ metal flush box/ cover plate/ junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LS cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including white wash/ distemper/ other painting to match the existing surface complete all as specified and directed. Note:- Cost of cutting chase and making good shall be included in the quated rates and wiring to be done as per approved colour code in IE rule.
All as per item No. 3.00 here-in-before but for one switch socket combination 5/6 Amps on independent board.
All as per item No. 3.00 here-in-before but for one three pin socket outlet 5 Amp on same board with other switches.
All as per item No. 3.00 here-in-before but for one switch socket combination 6 pin 5/15 Amps on independent board with wire of size 2.5 Sqmm in main and earth wire.
All as per Srl item No. 3.00 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm in main and earth wire.
M&L for surface casing caping of size 25mm size/ open conduit point wiring for one light/fan/exhaust fan controlled by one switch complete with and including single core PVC insulated unsheathed flexible conductor FRLS cables 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium grade PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular/ non modular type all accessories/fitting / metal flush box / cover plate/junction boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LS cable as continous earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including white wash/ distemper/ other painting to match the existing surface complete all as specified and directed. Note:- Wiring to be done as per approved colour code in IE rule.
All as per item No 8.00 here-in-before but for one light point controlled by 5/6 Amp, two way switch on independent board.
All as per item No. 8.00 here-in-before but for one switch socket combination 5/6 Amp on independent board.
All as per item No. 8.00 here-in-before but for one three pin socket outlet 5 Amp on same board with other switches.
All as per item No. 8.00 here-in-before but for one switch socket combination 6 pin, 5/15 Amps on independent board with wire of size 2.5 Sqmm in main and earth wire.
All as per item No.8.00 here-in-before but for one switch socket combination 6 pin, 5/15 Amps on independent board with wire of size 4.0 Sqmm in main and earth wire.
S&F of switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and directed.
S&F of switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed.
S&F of bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and directed.
S&F of switch piano, one way, single pole, 15 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and directed.
S&F of socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type, 240 volt AC complete all as specified and directed.
S&F of socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp, flush type, 240 volt AC complete all as specified and directed.
S&F of switch socket combination outlet multipurpose with PVC gang box, 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC ISI marked complete all as specified and directed.
S&F of ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and directed.
S&F in repairs buzzer electric, single phase, 240 volt, AC complete all as specified and directed.
S&F in repairs bell, ding dong type, electric, single phase, 240 volt, AC complete all as specified and directed.
S&F in repairs bell, multi music type, electric, single phase, 240 volt, AC complete all as specified and directed.
S&F of angle holder, PVC/Poly carbonate type with back plate suitable for batten fittings complete all as spcified and directed.
S&F of batten holder, PVC/Poly carbonate type with back plate suitable for batten fittings complete all as spcified and directed.
S&F of LED type tube light fitting, surface mounted lumanaires, 18 W, 240V, decorative ultra slim round /square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps, connector block, etc. with all accessories and connecting up with flexible 3 core copper conductor cable of suitable size including taking out old tube light fitting of any type complete all as specified and directed.
S&F of warm white in colour LED tube light fitting, surface mounted luminanaires, 18 watt, 240V, decorative ultra slim round/square profile LED lighting fixture with extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with bipin holders, LED Lamps, connector block, etc complete with all accessories internally prewired and connecting up with flexible 3 core copper conductor cable with suitable size including taking out old tube light fitting of any type complete all as specified and directed.
S&F of LED tube rod 20 watt, 240V, PV > 0.90, colour temp 6500 K, complete with all accessories including connecting up with flexible 3 core copper conductor cable with suitable size including taking out old tube light fitting of any type complete all as specified and directed.
S&F of white LED tube light fitting, two feet, 10 watt, slim design, 230 volts complete with all accessories including connecting up with flexible 3 core copper conductor cable with suitable size including taking out old tube light fitting of any type complete all as specified and directed.
S&F of warm white LED Tube light fitting two feet 10 watt, slim design, 230 volts, complete with all accessories including connecting up with flexible 3 core copper conductor cable with suitable size including taking out old tube light fitting of any type complete all as specified and directed. Note for item No. 27 ot 31:- Contractor will produce manufacturer test certificate and min two year warrenty from date of fixing.
S&F of ceiling fan regulator, electronic step type 240 V, AC 50 Hz, single pole, 100 watts flush/socket type complete all as specified and directed.
S&F in replacement ceiling fan capacitor of capacity 2.5 MFD complete all as specified and directed. Make: Epcos/Havells/Tibcon.
S&F in replacement exhaust fan capacitor of capacity 4.0 MFD complete all as specified and directed. Make: Epcos/Havells/Tibcon.
S&F in repairs PVC insulated unsheathed, ISI marked FRLS copper cable, 1.5 Sqmm AC 230 V complete all as specified and directed.
S&F in repairs PVC insulated unsheathed, ISI marked FRLS copper cable, 2.5 Sqmm AC 230 V complete all as specified and directed.
S&F of modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular switch, one way, 16 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular bell push switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular socket outlet 2-in-1, 5 pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
S&F of modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, complete all as specified and directed.
S&F of modular switch socket combination, multipurpose 6 pin, 6/16 amp, 3 module complete all as specified and directed.
S&F of modular fan regulator, 5 step, high speed complete all as specified and directed.
S&F of modular metal flush box of 6 module complete all as specified and directed.
S&F of modular metal flush box of 4 module complete all as specified and directed.
S&F of modular metal flush box of 3 module complete all as specified and directed.
S&F of modular white cover plate with frame of 6 module complete all as specified and directed.
S&F of modular white cover plate with frame of 4 module complete all as specified and directed.
S&F of modular white cover plate with frame of 3 module complete all as specified and directed.
Taking down unservicable sub main wiring including service connections, of any size and any description and making good disturbed surface of walls/ ceiling to match with existing surface complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with four single core PVC insulated ISI marked FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area with and including drawing into 20 mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade with all fittings in concealed wiring system by cutting chasing in walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note: (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor and PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with four single core PVC insulated ISI marked FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area with and including drawing into 20 mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade with all fittings in concealed wiring system by cutting chasing in walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note: (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor and PVC conduit pipe shall be measured as one unit length.
Taking down old unserviceable MCCB/MCB DB of any size and capacity including MCCB/MCB and wooden/metal boards complete all as specified and directed.
S&F of factory made sheet metal enclosure for MCB, DB, TPN, 415 Volts, 200 amps rated busbar, 4 way, double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangular board of first class hardwood of suitable size for mounting of DB box complete all as specified and directed. NOTE:- MCB shall be measured and paid seperately.
S&F of factory made epoxy powder coated distribution board TP&N 4 ways (VTPN MCCB DB) and space for MCCB as incomer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated neutral bar, insulated busbar assembly, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts complete all as specified and directed. NOTE:- MCCB shall be measured and paid seperately.
S&F of factory made sheet metal enclosure double door type surface mounted concealed in wall SPN, 8 ways, 240 Volts, ISI marked 200 amps bus bar, dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. NOTE:- MCB shall be measured and paid separately.
S&F of sheet metal enclosure double door type surface mounted concealed in wall, SPN ,12 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. NOTE:- MCB shall be measured and paid separately.
S&F of MCCB 160 Amp, 3 Pole, breaking capacity 36 KA and making all electrical connections by appropriate size of copper lugs complete all as specified and directed.
S&F of MCB, SP, 240 volts, 10 KA breaking capacity, 'B' curve, of capacity 6 to 32 amps including connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, SP, 240 volts, 10 KA breaking capacity, 'B' curve, of capacity 40 amps including connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, SPN suitable for 240 volts, 'B' curve, AC supply 6 to 32 Amps with over load and short circuit protection and rupturing capacity not less than 10KA including connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, SPN suitable for 240 volts, 'B' curve, AC supply 40 to 63 Amps with over load and short circuit protection and rupturing capacity not less than 10KA including connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, TPN suitable for 240 volts, 'B' curve, AC supply 63 Amps with over load and short circuit protection and rupturing capacity not less than 10KA including connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, TPN suitable for 240 volts, 'B' curve, AC supply 100 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA including connection with suitable size copper lugs complete all as specified and directed.
S&F in repairs 3 pin plug top AC-230 V, 5 Amp complete all as specified and directed.
S&F in repairs 3 pin plug top AC-230 V, 15 Amp complete all as specified and directed.
S&F in repairs single pole and neutral sheet metal enclosure with two pin and earth, plug and socket, suitable for single phase 240 V with and including one single pole MCB of capacity 20 amps, `C` charactristic, breaking capacity 10 KA including industial plug top complete all as specified and directed.
S&F in replacement PVC insulated PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC, 230 V and making necessary connection complete all as specified and directed.
S&F in replacement non metallic rigid PVC casing and caping, medium grade, ISI marked of 20 mm size complete all as specified and directed.
S&F in replacement non metalic PVC conduit, medium grade, ISI marked of size 20 mm dia complete all as specified and directed.
S&F in replacement LED ultra slim decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt white in colour with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable of size 0.5 sqmm three core complete all as specified and directed.
S&F in replacement LED ultra slim decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt warm white in colour with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core complete all as specified and directed.
S&F in replacement post top lantern fitting 25 watt (for gate light), energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with all accessories and making connection with PVC insulated multistranded copper flexible cable 0.5 sqmm three core all as specified and directed.
S&F in replacement building security light fitting made up of pressure die cast alluminium housing with high efficient 30 Watt LED as lighting source and pc over having top opening separate driver compartment with IP-66 protection and including IK 08 protection suitable galvanized iron pipe 32 mm bore, light grade 1 mtr length bent to shape to obtain required shape including clamps, nuts/bolts/washers etc; and connecting with PVC insulated multistranded copper flexible cable of size 0.5 sqmm three core copper wire complete all as specified and directed.
S&F in replacement flexible wire three core copper conductor of size 23/0.0076 for ceiling fans, light fittings etc complete all as specified and directed.
S&F in replacement of LED slim square/circular panel light fitting for surface ceiling light 12 watt, colour warm white including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector complete all as specified and directed.
S&F in replacement recess mounting spot LED light round down lighter designed with excellent thermally managed luminaire 12 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with driver three core flexible coppder conductor cases of suitable size complete all as specified and directed.
S&F of flexible LED strip with high brightness SMD LED as the light source for indoor application only, luminaire 24 watt, 220 V AC with high efficiency light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement LED decorative wall light, gold finish fixture with white glass diffuser suitable for 9 W LED bulb E27 base and making necessary connections complete all as specified and directed. Make: Havells (Gobleto WL 1LS E27 GLD) Cat part No-LHFOAKD1TZ1D060 or equivalent in Philips/ Bajaj/ C&G
S&F in replacement garden light 8W bamboo landscape light LED luminaire, new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light source and making necessary connections complete all as specified and directed. Make - Havells/ Philips/ Bajaj / C&G
S&F in replacement curved 6 watt LED warm white adjustable multiple angle mirror light including inbuilt LED driver new generation, energy saving, environmental friendly, long life aesthetically designed for diffused lighting with high power LED as light source complete all as specified and directed. Make - Havells/ Philips/ Bajaj / C&G
S&F in replacement 3 watt LED warm white rotate in 360 degree angle bed side light including inbuilt LED driver energy saving, environmental friendly, long life aesthetically designed aluminium landscape for diffused lighting with high power LED as light source complete all as specified and directed. Make - Havells/ Philips/ Bajaj / C&G
M&L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing including taking out old earthing complete all as specified and as directed.
M&L for re-winding of ceiling fans AC single phase 230 volts of sizes 1200mm/1400mm (collected from MES fan store) any make/ model including cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, replacement of ball bearing of suitable size, cleaning of bearing housing and shaft, replacing minor parts such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES fan store after testing complete all as specified and directed. Note for item no 84.00 to 88.00 (i) Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the SI Line E/M yard in presence of concern JE E/M. (ii) Space/room will be provided by AGE E/M in the E/M yard for carring out repair work. (iii) Contractor staff will collect defective fans from concern JE E/M, check the fans after opening it and intimate the defects in the fan to JE E/M before carring out the repairs. (iv) Bearing shall be measured and seperately under respective item as for supply only.
All as per item No. 84.00 here-in-before but exhaust fan, 400/450 mm sweep, AC single phase, 230/240 volts.
All as per item No. 84.00 here-in-before but exhaust fan, 300/380 mm sweep, AC single phase, 230/240 volts.
All as per item No. 84.00 here-in-before but exhaust fan, 230/250 mm sweep, AC single phase, 230/240 volts.
All as per item No. 84.00 here-in-before but wall / pedestal fan, of any sweep and capacity.
S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S&F in replacement upper set of clips for down rod with rubber bush (Garari) including set of nuts, bolts, washers and pin complete all as specified and directed.
S&F in replacement rubber bush (Garari) for mounting at upper side of down rod clip complete all as specified and directed.
S&F in replacement gun metal bush self lubricated, any size, suitable for ceiling and wall fans complete all as specified and directed.
S&F in replacement fan condenser 3.15 mfd, 230 volts complete all as specified and directed. Make: Epcos/Tibcon/Havells as approved by GE.
Supply only the bearing No. 6201 'ZZ' suitable for ceiling/ exhaust fans complete all as specified and directed. Make : SKF/NBC/FAG as approved by GE
Supply only the bearing No. 6202 'ZZ' suitable for ceiling/ exhaust fans complete all as specified and directed. Make : SKF/NBC/FAG as approved by GE
Supply only the bearing No. 6203 'ZZ' suitable for ceiling/ exhaust fans complete all as specified and directed. Make : SKF/NBC/FAG as approved by GE
Supply only the bearing No. 6204 'ZZ' suitable for ceiling/ exhaust fans complete all as specified and directed. Make : SKF/NBC/FAG as approved by GE
Taking down ceiling / wall fan from fan hook and disconnecting from ceiling rose, dismantling of fan parts i e. down rod and connector/condenser, nuts, bolts, split pins, rubber bush (garari), condenser carrier clip (PVC), in build connector two way, etc; complete with and incluidng M&L for servicing by cleaning, greasing/oiling in side surface of rotar by CTC with sand paper and carrying its all repair work and then re-fitting / reassembling and making the fan fuctional and fixing the fan in position after testing complete all as specified and directed. Note: Spares shall be measured seperately under respective item of Schedule 'A'.
Taking down exhaust fan and disconnection from ceiling rose, dismantling of fan parts i.e. connector/condenser, nuts, bolts, split pins, rubber bush (garari), condenser carrier clip (PVC), in build connector two way, etc; complete with and incluidng M&L for servicing by cleaning, greasing/oiling in side surface of rotar by CTC with sand paper and carrying its all repair work and then re-fitting / reassembling and making the fan fuctional and fixing the fan in position after testing complete all as specified and directed. Note: Spares shall be measured seperately under respective item of Schedule 'A'.
S&F in repairs down rod for ceiling fans duly painted with two coats of synthetic enamel paint 300 mm long & 19 mm outer dia with holes on both ends of the rod for connection wire complete all as specified and directed.
S&F in repairs down rod for ceiling fans duly painted with two coats of synthetic enamel paint 600 mm long & 19 mm outer dia with holes on both ends of the rod for connection wire complete all as specified and directed.
S&F in repairs exhaust fan metal blade duly powder coated suitable for 450 mm/380mm sweep fans as per existing complete all as specified and directed.
S&F in repairs exhaust fan metal blade duly powder coated suitable for 300 mm/230mm sweep fans as per existing complete all as specified and directed.
S&F in repairs blade assembly of celling fan suitable for 1200 mm sweep (set of three) fan of any make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs blade assembly of celling fan suitable for 1400 mm sweep (set of three) fan of any make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs outer frame complete with clamps, rubber packing, nuts, bolts with all accessories duly painted suitable for 450 mm /380 mm sweep exhaust fans complete all as specified and directed.
S&F in repairs outer frame complete with clamps, rubber packing, nuts, bolts with all accessories duly painted suitable for 230 mm /300 mm sweep exhaust fans complete all as specified and directed.
S&F in repairs top and bottom PVC canopy of ceiling fan of any sweep, make, colour and pattern as per existing model complete all as specified and directed.
M&L for applying two coats of DUCO paint (ISI grade) using spray machine including cleaning, washing and preparation of old painted surfaces and writing MES Nos on ceiling fans upto 1200/1400 mm sweep complete all as specified and directed.
M&L for applying two coats of DUCO paint (ISI grade) using spray machine including cleaning, washing and preparation of old painted surfaces and writing MES Nos on exhaust fan of 280/300/380/450 mm sweep complete all as specified and directed.
Dismantling of cabin fan of any sweep and overhauling by means of cleaning of stator, oiling and greasing including replacement of nuts, bolt and other minor parts and reassembling and re-fixing in posiion after testing complete all as specified and directed.
Removing unserviceable fan bearing shaft (of any type of fan) with and includng M&L for welding broken shaft area and threading in lathe machine to appropriate size and refixing in ceiling fan complete all as specified and directed.
S&F in replacement building LED security light fitting, 30 watt, pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out of GI light grade pipe 32 mm dia and 1.5 metre long with MS clamps, nuts, bolts, washers and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed.
Dismantling geyser of 25/50 ltrs capacity and of any description with and including M&L for cleaning, de-scaling the inner tank, inlet, outlet, overflow, geyser element, thermostat, U-assembly etc. with brush and cleaning rods using concentrated de-scaling solution mixed with water in suitable proportion till complete deposits/scale is removed and brazing if required for stopping the leakage of copper inner tank by gas welding for stopping the leakage of inner steel tanks, fixing serviceable parts in position, setting insulation properly as required, reassembling the complete geyser and fixing same in existing position and testing for its smooth functioning complete all as specified and directed. NOTE: Spares as required shall be measured and paid seperately.
S&F of 1.5 KW capacity heating element (ISI marked) round type/thread/triangle/push/ screw base type with ‘O’ ring including making electrical connection complete all as specified and directed. Make: Bajaj/ Usha /Theta
S&F of 2.0 KW capacity heating element (ISI marked) round type/thread/triangle/push/ screw base type with ‘O’ ring including making electrical connection complete all as specified and directed. Make: Bajaj/ Usha /Theta
S&F of electronic heating element (ISI marked) fitted with auto cut thermostat 1.5/2.0 KW suitable for 25/50 ltr geyser including making electrical connections complete all as specified and directed. Make: Bajaj/ Usha /Theta
S&F in replacement stainless steel geyser assembly 6/8 holes suitable for 25 ltr capacity, ISI marked complete all as specified and directed.
S&F in replacement stainless steel geyser assembly 6/8 holes suitable for 50 ltr capacity, ISI marked complete all as specified and directed.
S&F in replacement thermostat suitable for 25/50 Ltr geyser ISI marked with setting range 30 C to 80 C suitable for 230 volts AC electric supply complete all as specified and directed. Make : Dasfass / Ranco / Indfoss
S&F in replacement inner tank made of stainless steel suitable for 25 Ltr geyser complete all as specified and directed.
S&F in replacement inner tank made of stainless steel suitable for 50 Ltr geyser complete all as specified and directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 25 Ltr geyser complete all as specified and directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 50 Ltr geyser complete all as specified and directed.
S&F in replacement bottom cover made of steel duly powder coated suitable for 25 Ltr geyser complete all as specified and directed.
S&F in replacement bottom cover made of steel duly powder coated suitable for 50 Ltr geyser complete all as specified and directed.
S&F in replacement indicating lamp (set of two) 230 volts 50 HZ AC suitable for geysers of any type (round, square or rectangular type) complete all as specified and directed.
M&L for applying two coats of DUCO painting to Geysers of 25/50 ltr capacity using spray machine including cleaning, washing and preparation of old painted surfaces and writing MES Nos complete all as specified and directed.
S&F in replacement PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in replacemnt PVC connections 15 mm size nylon braided, heavy duty, 450mm long including rubber washers (suitable for hot water) complete all as specified and directed.
S&F in replacement pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified and directed.
S&F of electric water heater storage type (Geyser) of steel body powder coated with copper inner tank and heating element upto 2 KW of capacity 25 litre, BEE 5 Star rated with all accessories such as safety valve, thermostate, NRV etc.complete all as specified and directed.
S&F of 250mm sweep exhaust fan made of sturdy engineering plastic body with louvers shutter, voltage 230 V, 50 Hz, 1200 RPM and making necessary connection with flexible cable of required size complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 112617.00
Raj Contruction
HRK ENGINEERING CORPORATION
Neelam Traders
PRADEEP SISODIYA
PRADEEP TIWARI CONTRACTOR
UMESH ENTERPRISES
S R BUILDERS AND SUPPLIERS
Vinayak Trading House
Makewell Enterprises
HARNAM SINGH ANIL SINGH
RAJPATI CONSTRUCTION
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .