Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹28.2 LAdmitted-Finance GODAVERI COMPLEX 1ST FLOOR BLOCK NO 104 MAIN ROAD HALDUCHAUR HALDWANI 263139 | NAINITAL | UTTARAKHAND | 263139 | ₹28.2 L | Admitted-Finance |
| 2 | Rejected-Technical | - | Rejected-Technical Uploaded past orders are not fulfilling the PQR criterial clause 6(b) of nit for the requisite value. |
| 3 | Rejected-Technical | - | Rejected-Technical Uploaded past orders are not fulfilling the PQR criteria clause 6(b) of NIT |
| 4 | Rejected-Technical WARD 14 PANDIT JAWARHLAL NEHRU NAGAR CHAKARBHATA WARD BILASPUR 495001 CHHATTISGARH | BILASPUR | BILASPUR | CHHATTISGARH | 495001 | - | Rejected-Technical a. Uploaded past orders are not fulfilling the PQR criteria clause 6(b) of nit for the rquisite value. uploaded annexure-IX for no banning black listing delisting on non-judicial stamp paper of Rs 100 instead of Rs. 200. hence cannot be considered |
| 5 | Rejected-Technical | - | Rejected-Technical a. Udyam certificate uploaded and exemption for EMD taken on portal. however certificate issued in the state of gujarat. Hence cannot be considered. b. Uploaded past orders are not flfilling the PQR criteria clause 6(b) of NIT for the rquisite valvue |
| Sl No | Description | Qty | Unit | M/S. ARUDRA ENGINEERS PVT LTD |
|---|---|---|---|---|
| 1.00High Pressure Hydrojet Cleaning of Steam Condenser tubes of unit no. 1 at 2X600 MW | ||||
| 1.10 | Cleaning of Condenser tubes by High Pressure Hydro Jetting @ 600-800 bar pressure.
Technical Specification of Condenser tubes: -
Cooling Water Flow: 66000 M3/Hr (Total for Two Condensers)
Number of Passes: 02
Length: 13000 mm Total no. of Cooling tubes: 2 x 17266 = 34532 Nos.
Condensing Zone- 2x15764 Nos.
Air Cooling Zone- 2x1502 Nos.
Size of Cooling Tubes-
Dia. 28.575 x 0.7112 mm
Dia.28.575 x 0.889mm (For Top Two Rows)
Material of tubes: S.S.-304 | 34,532 | Nos. | 5,17,980 ₹6.1 L |
| 2.00High Pressure Hydrojet Cleaning of Steam Condenser tubes of unit no. 3 & 4 at 2X660 MW | ||||
| 2.10 | Hydrojet cleaning of condenser tubes of U# 3 & 4
• No. of tubes in a single condenser= 31252 with 30.16mm triangular pitch
• No. of condensers in single unit = 2 (one HP and one LP condenser)
• No. of equipment to be provided for cleaning simultaneously, quadruple or double operative at time.
• Both condenser cleaning to be done simultaneously in a unit throughout 24 hrs shifts
• Hydro jet pressure= 500 bar
Condenser Tube Details:
impingement zone condensing zone Air cooled zone
No of tubes for one 660 MW unit (nos) 3752 53752 5000
OD 22.225 mm 22.225 mm 22.225 mm
ID 20.447 20.803 19.735
Thickness 0.889 mm 0.711 mm 1.245 mm
MOC TP 304 SS TP 304 SS TP 304 SS | 1,25,008 | Nos. | 18,75,120 ₹22.1 L |
Updated dates
Tender Value
₹26.7 L
EMD Value
₹53,400
Closing Date
19 Jan 2026, 3:30 pmClosed
CE(Gen), SSTPP Dongalia
IIIrd Floor Admin Building SSTPP
Work contract for High Pressure Hydrojet Cleaning of Steam Condenser tubes of unit no. 1 at 2x600 MW and unit no 3 and 4 at 2x660 MW at SSTPP, MPPGCL, Dongalia.
2025_MPPGC_459316_1
WT-2847/MM-II
Open Tender
Miscellaneous Works
15 days
Addl. C.E.(P and W)SSTPP, Dongalia
Please refer Tender documents.
18 documents required · 18 mandatory
₹1,000
Yes
₹53,400
Yes
29 Apr 2026
9 Dec 2025
20 Jan 2026
9 Dec 2025
19 Jan 2026
9 Dec 2025
High Pressure Hydrojet Cleaning of Steam Condenser tubes of unit no. 1 at 2X600 MW
Cleaning of Condenser tubes by High Pressure Hydro Jetting @ 600-800 bar pressure. Technical Specification of Condenser tubes: - Cooling Water Flow: 66000 M3/Hr (Total for Two Condensers) Number of Passes: 02 Length: 13000 mm Total no. of Cooling tubes: 2 x 17266 = 34532 Nos. Condensing Zone- 2x15764 Nos. Air Cooling Zone- 2x1502 Nos. Size of Cooling Tubes- Dia. 28.575 x 0.7112 mm Dia.28.575 x 0.889mm (For Top Two Rows) Material of tubes: S.S.-304
High Pressure Hydrojet Cleaning of Steam Condenser tubes of unit no. 3 & 4 at 2X660 MW
Hydrojet cleaning of condenser tubes of U# 3 & 4 • No. of tubes in a single condenser= 31252 with 30.16mm triangular pitch • No. of condensers in single unit = 2 (one HP and one LP condenser) • No. of equipment to be provided for cleaning simultaneously, quadruple or double operative at time. • Both condenser cleaning to be done simultaneously in a unit throughout 24 hrs shifts • Hydro jet pressure= 500 bar Condenser Tube Details: impingement zone condensing zone Air cooled zone No of tubes for one 660 MW unit (nos) 3752 53752 5000 OD 22.225 mm 22.225 mm 22.225 mm ID 20.447 20.803 19.735 Thickness 0.889 mm 0.711 mm 1.245 mm MOC TP 304 SS TP 304 SS TP 304 SS
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tendernotice_2.pdf
PDF • 0.47 MB
NEWSBDworkservices.pdf
Tender Documents • 30.17 MB
Tenderschedule2847.pdf
Tender Documents • 0.45 MB
NITdetails2847.pdf
Tender Documents • 0.30 MB
NIT2847.pdf
Tender Documents • 0.13 MB
BOQ_548976.xls
BOQ • 0.38 MB
TechnicalBiD2847.xls
Additional Documents • 0.31 MB
Credentials.xls
Additional Documents • 0.09 MB
ModelCertificate.pdf
Additional Documents • 0.17 MB
Newannexuresaffidavit.pdf
Additional Documents • 0.82 MB
Download all tender documents and submit your bid