Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.9 L+₹1.9 L (17.5%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L2 | Rejected-Finance Not Being Eligible | |
| 3 | L3₹13.0 L+₹2.0 L (18.1%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance Not Being Eligible | |
| 4 | L4₹13.8 L+₹2.9 L (26.0%)Rejected-Finance | L4 | Rejected-Finance Not Being Eligible | |
| 5 | L5₹14.3 L+₹3.4 L (30.6%)Rejected-Finance | L5 | Rejected-Finance Not Being Eligible |
Tender Value
₹12.2 L
EMD Value
₹24,500
Closing Date
19 Jun 2020, 6:00 pmClosed
CWE AF SOUTH BANGALORE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVN OF 400KVA TRANSFORMER FEEDING TO BUILDING NO P 1 AND OTHER FACILITIES AT CQAE (WE) JALAHALLI BANGALORE
2020_MES_345094_1
85183
Open Tender
Civil Works
Item Rate
120 days
Jalahalli Bangalore
As per tender documents
7 documents required · 7 mandatory
₹500
GE (M) (AF) Jalahalli
₹24,500
Yes
30 Jun 2020
15 May 2020
22 Jun 2020
15 May 2020
19 Jun 2020
29 May 2020
16 May 2020 - 22 May 2020
Amount
Supply, install, test and commissioning copper wound step down transformer, out door type complete with stranded fittings, HT, 11 KV, 3 phase, LT, 433 V, 3 phase, 4 wire with off load tapings on Primary side to vary secondary voltage + / - 7.5% with tapings at every 2.5% rating of capacity 400 KVA including bushing on HT side and LT side all as per IS-1180 with energy efficiency level 2 complete with all standard fittings and accessories all as specified and directed comprising following accessories :- Note : This item includes the following (a) HT Cable box comprising of three Nos porcelain bushings HT 11 KV with brass bushing rods nuts and washers. (b) LT cable box on LV side consisting of four Nos porcelain with brass bushing rods complete with nuts and washers with two Nos cable gland suitable for 3.5 core 400 sqmm LT U/G cable. (c) Oil conservator with filler type drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e) Explosion vents. (f) Thermometer pocket on tank cover. (g) Rating plate and terminal marking plate. (h) The earthing terminal two Nos to facilitate fixing of earth strip. (i) Oil filling hole with cap/plug with connection plate complete. (j) Air relief valve plug. (k) Initial filling to transformer oil. (l) PCC block platform of suitable size in cement mortar 1:6 with PCC foundation 1:4:8 type D-2 using 40mm graded stone aggregate, PCC 1:2:4 type B-1 using 20mm graded stone aggregate 20 cm thick coping over brick work plastering to exposed surface of platform. (m) Two Nos GI tubing light grade 100mm dia and suitable length embedded in brick wall on LT/HT side for drawing underground cable. Note :The Quoted Rate for this item is deemed to be included for Note (a) to (m).
Material and labour for XLPE insulated, screened PVC bedded, galvanized strip, armoured , electric power cable , heavy duty , with aluminium conductor 11 KV (E) grade, cross sectional area 120 Sqmm, 3 core confirming to IS-7098 ( Part II ) (amended upto date ) including supplying, jointing and testing, complete all as specified and as directed.
M&L insulated armoured heavy duty electric XLPE cable with aluminium conductor 1100 volts grade cross sectional area 400 sqmm 3.5 core including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Material and labour for cable jointing kit for 11 KV (E) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Material and labour for cable jointing kit for 11 KV (E) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in hard /dense soil all as directed.
Returning filling in including spreading, leveling Watering and well ramming in layers not exceeding 25cm all as directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Supply and spread fine river sand in trenches, as in cable cushioning all as directed. Note :-For payment purpose only punned thickness will be considered .
Supplying & laying un-reinforced precast concrete cable cover, class HV,Type 1, flat, size 300 mm x 180 mm x 40 mm abutting each other with gap between adjacent slab not exceeding 10mm over under cable for protection all as specified and as directed.
Brick protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified.
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (Earth pit not less than 2.25m below ground level). The top edge of earth plate not less than 1.5 mtr below ground level connected to GI strip 32x6 mm as earth lead by means of nuts, bolts, thimbles, check nuts, washer of GI or steel at two places including PCC (concrete chamber) shall be PCC 1:3:6 type C-I by using 20 mmgrade stone aggregate with finish internal surface of concrete chamber shall be given 15mm thick plasterin CM 1:4, funnel with wire gauge, 80 mm thick RCC pit cover, 320x320mm of RCC 1:2:4 type B-I using 20 mm graded stone aggregate reinforced with XPM jalli, charcoal dust and common salt all as shown in electrical plate no. 5 of SSR Part-I 2009 and specified including provn of GI strip protected by 40mm dia med grade pipe and water pipe shall be 20 mm bore medium grade, including all excavation works, earth work and connecting the earthing lead to an earth test point/main switch/MCB DB's and testing after completion complete all as specified and directed by Engineer-in-Charge.
All as per item No.12 here-in-before but using 20 x 3 mm copper strip and copper plate of size 600 x 600 x 3.15 mm, as earth electrode complete all as specified and as directed.
M/S SRI BALAJI ENTERPRISES
devan enterprises
Thirumala Construction
kamadhenu Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .