Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹38.2 L+₹6.0 L (18.5%)Rejected-Finance 15 1 1F MAYUR BHANJ ROAD POLICE STATION EKBALPORE KOLKATA 700023 | KOLKATA | KOLKATA | WEST BENGAL | 700023 | L2 | Rejected-Finance Being higher bid Value | |
| 3 | L3₹38.7 L+₹6.5 L (20.0%)Rejected-Finance | L3 | Rejected-Finance Being higher bid Value | |
| 4 | L4₹39.6 L+₹7.4 L (22.8%)Rejected-Finance | L4 | Rejected-Finance Being higher bid Value |
Tender Value
Refer Docs
EMD Value
₹71,000
Closing Date
21 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8947/E8
2021_MES_442302_1
GE/ALP (8947) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE ALIPORE KOLKATA
Class D and Category a i
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹71,000
Yes
5 Aug 2021
12 May 2021
22 Jun 2021
12 May 2021
21 Jun 2021
7 Jun 2021
60 days
Amount
BSA/KOL/SR(E/M)/13/2020-21 Taking down old BER water heater storage type by removing the nut and bolts from the wall , remove the connections of PVC connections for hot and cold water supply, stop cock etc complete all as specified and as directed. (Note : The old removed Geyser to be returned to MES E/M storeyard)
Supply and fixing of Water heater storage type, electric, storage capacity 25 litres and 2.0 KW 230V BEE 5 star rated vertical type with proper fixing on wall with suitable rag bolts and including making the water supply connection with PVC connections of suitable length for hot and cold water with one pair connecting pipe of suitable length , electric connections including testing after installation complete all as specified and as directed. Make;- Havells Senzo Cat NO GHWASESIB025 or equivalent in Bajaj/Racold
BSA/KOL/LBW/46/2020-21(B/R) Excavation in trenches n. exc 1.50 m wide and n. exc 1.50 m in deep for foundation etc n. exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and as directed
Material and labour PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Use and waste of formwork to sides of concrete fdns, footings, bases of columns raft and raft beam sides and soffits (if any) of fdn and plinth beams and similar work vertical or to better rough finished surface of concrete complete all as specified and directed.
Material and labour reinforced cement concrete M-25 (design mix) as in fdn, incl rafts, footings, fdn beams, plinth beams, bases for columns etc. complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts,pipers,columns and rough finished surfaces complete all as specified and directed.
Material and labour reinforced cement concrete M-25 (design mix) as columns,pillars,piers,posts and struts complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beam, beam haunchings, girders, bressummers, lintel etc and rough finished surfaces complete all as specified and directed.
Material and labour reinforced cement concrete M-25 (design mix) as in beam, lintels over 1.5m span etc complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs n.exc 200mm thick fair finished concrete surface. complete all as specified and directed.
Material and labour reinforced cement concrete M-25 (design mix) as in slabs supported on wall, beams and columns in floors, roofs, landing etc. complete all as specified and directed.
Material and labour TMT bars 10mm dia and over cut to length, bent to shape as required including cranking bending spirally for hoping for column hooking ends and binding with MS wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
Material and labour TMT bars 6mm dia to 8mm dia as in stirrups, spacers and binders etc.cut to length bent to shape required including cranking bending spirally for hoping for column hooking ends and binding with MS wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
Material and labour Brick work with sub class B bricks, straight or curved on plan, exc 6 m mean radius, built in Cement mortar (1:6) complete all as specified and directed.
Material and labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in Cement Mortar (1:4) complete all as specified and as directed.
Material and labour rendering on walls ,15 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for rendering on walls ,15 mm thick in cement mortar (1:6) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Cutting grooves in brick wall ,75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Material and labour rendering on Ceiling ,5mm thick in cement mortar (1:3) on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Supply and fixing vitreous china wash down water closet (Pedestal) including PVC seat cover closed pattern with flat bottem and cover and mild steel chromium plated hinge device,,connection to drain or outgoing pipe and to flushing pipe, anti-syphonage pipe, joint to socket or stoper etc. complete all as specified and as directed
Supply and fixing in repair PVC valveless, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia complete all as specified and as directed
Supply and fixing CP Health faucet with all necessary fittings. complete all as specified and as directed.
Supply and fixing vitreous china wash hand basin, white, flat back, size 550mm x 400mm excluding chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed. Note : Rate quoted under this item deemed included fixing of taps, plug and chain and connecting up to supply pipes, wastes or traps etc.
Supply and fixing 15 mm bore pillar taps, chromium plated with capstan heads, chromium plated, Fancy type screwed down for pipe, high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed.
Supply and fixing 15mm bore stop valve, chromium plated with crutch handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Supply and fixing 15mm Bib taps, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Supply and fixing 15 mm angular valve Chromium plated with fancy type chromium plated with high pressure, with crutch butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fixing Vitreous China bowl urinal flat back, size of 465x355x265 mm White ( minimum), with grating and union for discharge pipe ( excluding flushing cistern, flush pipe , and waste pipe) , including connections to flushing pipe and outgoing complete all as specified and directed.
Supply and fixing 32 mm dia PVC waste pipe for wash hand basin and urinal down pipe fixed complete all as specified and directed
Supply and fixing 5mm thick beveled edge best quality looking mirror of size 600x450 mm with 30 mm PVC beading all around the glass, mounted over 3mm thick PVC sheet complete all as specified and directed.
Supply and fixing Towel rail 600mm long of chromium plated fixed with and including chromium plated brass screws & wooden/plastic cleats complete all as specified and directed.
Supply and fixing 15 mm size, 600 mm long PVC connection pipe with PTMT nut complete all as specified and directed.
Supply and fixing 20 mm bore (Outer dia) CPVC pipes of SDR 11and plain/brass CPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors incl necessary fittings complete all as specified and directed.
Supply and fixing galvanised steel water 25 mm bore tubing (GI pipe), medium grade with all fittings and fixed to wall, floor and ceiling complete all as specified and as directed.
Supply and fixing 150 mm bore sand cast, soil iron and waste pipes, in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed.
Supply and fixing 150 mm bore sand cast,soil iron and waste pipes bends fixed with cement joints, fixed to walls complete all as specified and directed.
Supply and fixing 150 mm cast iron branch pieces, single (equal or unequal), ordinary or inverted(spigot or socket type) or with parallel branches complete all as specified and directed.
Material and labour 150 mm bore grade 'A' SGSW drain pipe laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed.
Supply and fixing CI Nahani trap of 100 mm dia, with grating incl jointing to waste pipe fixed in cement concrete, type B1 (1:2:4) complete all as specified and directed.
Supply and fixing CP mild steel gratings of 100mm dia complete all as specified and directed.
Material and labour PCC for concrete bed to drain pipe , 150 mm bore pipe including packing and under hunching against the sides of pipe after they are laid and tested in PCC (1:3:6) type C-2 using 40 mm graded stone aggreagate complete all as specified and directed.
Cutting into existing main hole for connecting new drains , making good to pipe and rendering ,cutting out existing benching for and forming branch channel ( half round or 3/4 section ) in cement concrete (1;2:4) type B-1 ,using 20 mm graded stone aggregate smooth finished and benching as required for 150 mm dia pipe complete all as specified and directed.
M&L Mild steel round bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips,Fe-410-S 0r Fe-410-O. complete all as specified and directed.
Material and labour precast cement concrete (1:2:4) type B-1, using 20mm graded aggregates as landings, cover slabs(for manholes etc),chullah hoods,chajjas,water troughs,mangers,shelves and similar articles with plain faces set in cement mortar (1:6) complete all as specified and directed.
Supply and fixing Brass chromium plated shower rose 125mm size complete all as specified and directed.
Material and labour for bedding layer of mortar 15 mm thick finished fair and even in CM 1:4 mixed with liquid water proofing compound on roof complete all as specified and as directed.
Material and labour for applying evely a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaniong surface on roof surface for fixing APP membrane complete all as specified and directed.
Material and Labour APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid over bitumen coated surfaces of roof applied with propane torch flames all as per manufacturers instructions. Note:- The APP membrane will have an overlap of 100mm on the end laps and 150mm on side laps. The overlaping and joints will be thermo sealed with the propane torch complete all specified and directed
Material and labour for applying protective coating with aluminium paint @ 0.2kg per sqm compete all as specified and directed.
Supply and fixing 1000 Ltrs Capacity rotational moulded polyethylene water storage tank, double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade wash out pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings complete all as specified and as directed.
Supply and fixing ball valve high pressure of PTMT 25 mm bore ( minimum weight 210gms) with epoxy coated aluminium rod and high density plastic ball screwed for iron pipes or brass ferrule and fixed complete all as specified and as directed.
M&L factory made solid panel PVC door frame of size 50mmx47mm out of 5mm plain colour PVC sheet reinforced with M.S. square tube,incl holdlfast all as per specification and drawing on SSR complete all as specified and directed.
Supply and fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with heat molded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for top rail and bottom rail on either side and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/seated to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame at site as per specification and drawing complete all as specified and directed.
Supply and fixing 100 mm size butt hinges stainless steel and fixed complete all as specified and directed.
S&F 30 mm thick factory made plain colour solid panel PVC Ventilator shutter consisting of frame made out of M.S. tube of 19 gauge thickness and size of 19 mm x 19 mm for stiles and 15 mm x 15 mm top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded Plain PVC ‘C’ channel of size 30 x 50 mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on the either side, 10 mm (5 mm x 2) thick, 20 mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Paneling SS wire mess 0.63 mm dia of wire and average width of aperture 1.18 mm of upper side of the lock rail and 4mm thick frosted glass of the lower side of lock rail. to be fitted in the M.S. frame welded to be stiles and rails with 30m wide x 5 mm thick PVC sheet beading on the either side and joined together with solvent cement adhesive etc. An additional 5 mm thick Plain PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ channel using PVC solvent cement adhesive etc. complete as per direction of Engineer-incharge, manufacturer’s specification & drawing.
Supply and fixing 3 mm thick sheet glass, ordinary quality and glazing with oil putty /wooden beads in square n. exc 0.5 sqm in each pane complete all as specified and as directed.
Supply and fixing aluminium handles cast type, anodised 150 mm. complete all as specified and as directed.
Supply and fixing 200 mm size aluminum anodised barrel tower bolt of extruded section complete all as specified and directed.
Taking down and refixing shutters in the same opening of area exc 1.0 sqm but not exc 2.0 sqm each of any description including easing and adjusting complete all as specified and directed.
Material and labour for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paints over and including a coat of red oxide primer complete all as specified and directed.
Supply and fixing framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars barred iron doors; ladders framed alusters; wald ways; railings; framework of water tanks and similar work confrming to Fe-290 Gde -E 165 complete all as specified and directed.
Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.
Material and Labour for complete removal of existing treatment and applying one coat wall care putty on old plastered surface, preparatory to distempering, priming plastered and other surfaces with chalk whiting and applying two coats of Acrylic distemper on Ceiling, pillasters, cornices etc complete all as specified and directed.
Material and Labour for preparation of Old plastered surfaces and applying two coats of Acrylic distemper on wall surface including preparation complete all as specified and directed.
Material and labour for preparing New decorated plastered of wall, pillasters, cornices etc and applying coat of 3 mm thick wall care putty with two coat acrylic distemper over a coat of primer complete all as specified and directed.
Material and labour broken stone or boulders hard core of gauge n.exc 63mm, deposited , spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and labour non skid, joint free, coloured ceramic tiles 7-8mm thick (Square/Rectunglar), as in floor etc ,area of each tile exc 0.11 Sqm but not exc 0.18 Sqm,.set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles, laid over and including15mm thick screed bed in Cement mortar (1:4) complete all as specified and directed.
Material and labour coloured Glazed ceramic tiles in vertical surface 450X 350X 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match and laid over and including 10mm thick rendering in Cement mortar (1:3) complete all as specified and directed.
Material and labour light shade Vitrified ceramic tiles 9-10 mm thick (Sqr/ rectangular) Polished, area of each tiles n.exc. 0.36sqm, in floors etc. set and jointed in neat cement slurry over and including a bedding layer of 15 mm thick iln Cement mortar (1:6) and pointed in white/colour cement to match complete all as specified and directed.
Material and labour 100 thick plain cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base of floor complete all as specified and directed.
Material and labour for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement including construction joint (30mm deep x 10mm wide) Grade A, complete all as specified and directed.
Material and labour for applying two coats of exterior emulsion paint(weather coat) on new surfaces over a coat of primer including a thin layer of wall care putty complete including preparation of surfaces and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in soft /loose soil complete all as specified and directed.
Removing excavated material ( soil) exc 1.50 KM but n.exc 5 KM and depositing at a level above the starting point complete all as specified and directed.
BSA/KOL/LBW/46/20-21 (E/M) Material and labour for point wiring for one light/fan point controlled by one one way switch,with 1.5 sqmm PVC insulated unshea-thed copper FRLS cable multistranded conductor 1100 volts grade (Red colour cable used for live connection, Black colour cable used for neutral connection and green cable used for earthing connection,Separate cable for earthing and neutral to be used for each individual circuit from the distribution board/Switch board) controlled by one way switch drawn through and including appropriate size of PVC casing capping with all accessoriese for surface wiring including 1.5 sqmm PVC insulatedun shealthed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to each point and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switches, socket and fan regulator with 3mm thick laminated bakelite laminated sheet cover all complete as specified and directed.
All as per item No 76 here-in-before but for 3 pin 5 Amps Switch Socket point on independent board with 1.5 Sqmm earth wire.
All as per item No 76 here-in-before but for 5 pin 15 Amps switch socket combination on independent board with 2.5 Sqmm eart wire.
M & L switch socket combination 2 in 1, 5 Amps, 240 V Flush type, uneversal all as specified and directed..
M & L switch socket combination 5 pin 5/15 Amps, flush type, 240 Volts, universal all as specified.
S & F switch piano type 5 Amp single pole one way all as specified and directed.
S & F ceiling rose surface backelite 65 x 50mm three terminal all as specified and directed.
Supply & fixing in repairs main stream battens fitting LED 20 watt tube 4 feet long fixing on PVC/wooden round block complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block all as directed. Make: C&S Cat No-LTDC0161820WLED or equivalent model in Havells/Philips/Bajaj/CG
M & L MCB SP of rating 6 to 32 Amps 240 V of capacity 10 KA ISI Marked.
M & L MCB SPN of rating 40 to 63 Amps Amps 240 V,of capacity 10 KA ISI Marked.
Supply and fixing MCB DB SPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge
Supply and fixing sub-main wiring (surface type) with PVC (FR-LSH) insulated & unsheathed two runs of 6 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 4 sq mm PVC (FRLS) insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through PVC casing & capping carefully complete all as directed. Note : Two runs of 6 sqmm and one run of 4 sqmm cable shall constitute one unit.
Supply and fixing exhaust fan AC 230/240V, 300 mm sweep complete with louvre including provision of hole for fixing of exhaust fan all as specified and directed by the Engr-in-Charge
Supply and fixing vertical storage type water heater (Geyser) of capacity 25 Ltrs with copper tank, 230 volts fixing the geyser with four Nos of rag bolts and making the electrical/water supply connection including testing after installation complete all as specified and as directed by Engr-in-Charge. Make : Racold Model :Altro or equivalent in Havells/Bajaj
Supply and fixing low density PVC flexible drain pipe of size 25 mm dia.complete all as specified and directed.
Supply and fix PVC inlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both ends sutiable to fix inlet of geyser complete all as specified and directed.
Supply and fix 450mm long brass CP connection with 2 nuts without nipple suitable for geysers. Make : Jaquar Cat No 805B or equivalent.complete all as specified and directed.
Supply and fixing 15 mm bore GI pipe medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Supply and fixing stop valves , cast copper alloy chromium plated of size 15 mm dia. complete all as specified and directed.
Supply and fixing bib taps, cast copper alloy fancy type chromium plated of size 15 mm dia. complete all as specified and directed.
BSA/KOL/LBW/48/2020-21(B/R) Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed.
Removing excavated material (soil) n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Material and labour for Anti termite treatment with Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
All as per item No 99 above but treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
All as per item No 99 above but Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
Material and labour for providing cement concrete 1:4:8 type D2 (Using 40mm graded stone agg) in foundation, mass concrete and filiings complete all as specified and directed.
Material and labour, providing reinforced cement concrete, M-25 (Design Mix), using 20 mm graded stone aggregate as in footing and plinth beams and the like complete all as specified and directed.
Material and labour, providing reinforced cement concrete, M-25 (Design Mix), using 20 mm graded stone aggregate, as in columns and the like complete all as specified and directed.
Material and labour, providing reinforced cement concrete, M-25 (Design Mix), using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
Material and labour, TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Material and labour, TMT bars 6 to 8 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Use and waste of formwork to sides of concrete fdns, footings, bases of columns raft and raft beam sides and soffits (if any) of fdn and plinth beams and similar work vertical or to better rough finished surface of concrete complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts,pipers,columns and rough finished surfaces complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beam, beam haunchings, girders, bressummers, lintel etc and rough finished surfaces complete all as specified and directed.
Supply and fixing rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fastening, heavy bracket framing (Beam, tee, angle, channel or flat section), including distance pieces, cleats etc. confirming to Fe – 410 – S including cutting, welding etc. complete all as specified and directed.
Supply and fixing rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
Supply and fixing, mild steel work such as post,truss, framed crane, gantries, rails and fastening (Beam, tee, angle, channel or flat section), including cleats, gussets/base plates of steel Fe, 410 W (Gde E-250) quality 'B' and similar work incl welding and riveting where required complete all as specified and directed.
Supply and fixing mild steel bolt hexagonal or square head one end and screwed the other or screw both ends to fe fitted with washer and one hexagonal or square nut exc 30cm long, exc 12 n exc 20 mm dia of neck all as specified and directed.
Material and labour for applying two coats of synthetic enamel paint over a coats of red oxide primer on new steel surface of any description over 10 cm width or girth, not otherwise specified including preparation of surfaces complete all as specified and directed..
Supply and fixing pre painted galvatume aluminium zinc coating GI corrogated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw etc complete all as specified and directed.
Supply and fixing pre painted galvatume aluminium zinc coating GI plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw etc complete all as specified and directed.
Material and labour pre cast cement concrete solid block masonary (1:3:6) type C1(using 20mm graded stone aggregate) exceeding 10cm thick and set in cement mortar (1:6) complete all as specified and as directed.
Material and labour rendering 15 mm thick in cement mortar (1:6) on fair faces of concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Material and labour rendering 15mm thick in cement mortar (1:4) on other than fair faces of concrete surfaces, finished even and smooth complete all as specified and directed.
Material and labour preparation of new surface and apply three coat of white wash on the walls. complete all as specified and as directed.
Material and labour for applying two coats of cement base paint over a coat of primer on cement plaster wall surfaces including preparation of surface. complete all as specified and as directed.
Supply and fixing Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and diected. (Height of bldg upto 12 storey)
All as per item No 123 above but without glazing bar complete all as specified and as directed.
Supply and fixing Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 (Height of bldg upto 12 storey) complete all as specified and as directed.
Supply and fixing steel rolling shutters of 1.25 mm thickness laths with ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete push & pull & gear operated type with bevel gear box and crank handle. complete all as specified and as directed.
Material and labour silver sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed by the Engr-in-Charge.
Material and labour hardcore of gauge n.exc. 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface for plinth protection complete all as specified and as directed.
Material and labour for providing cement concrete 1:4:8 type D2 (Using 40mm graded stone agg) , 75mm thick as in sub base in floor/paving etc. complete all as specified and as directed.
Material and labour for providing cement concrete 1:2:4 type B1 (Using 20mm graded stone agg) , 50mm thick as in floor/paving finishing used extra cement etc. complete all as specified and as directed.
Material and labour Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 20mm thick screed bedding in Cement mortar (1:6) including rubbing and polishing complete all as specified and directed.
Material and labour for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement including construction joint (30mm deep x 10mm wide) Grade A, complete all as specified and directed.
Material and labour cement concrete 1:3:6 Type - C2 (using 40mm graded stone aggragate) as benching in surface channel & drain complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 Cm inner girth in cement concrete, using extra cement, including forms moulds mi-tred stopped ends etcs complete all as specified and as directed.
Material and labour 100mm thick PCC type C-2 1:3:6 (40mm graded stone aggregate) as in flooring and paving etc finishing the surfaces rough for floor finishes complete all as specified and directed.
M&L Chequered cement concrete tiles 40cm x 40cm x 25mm thick, set, jointed and pointed with grey cement and pigment in floors over and including 20mm thick screed bedding in Cement mortar (1:6) complete all as specified and directed.
BSA/KOL/LBW/48/2020-21(E/M) Material and labour for point wiring for one light/fan/call bell point controlled by One Way switche,with 1.5 sqmm PVC insulated unsheathed copper cable multistrand conductor 1100 volts grade (Red colour cable used for live connection, Black colour cable used for neutral connection and green cable used for earthing connection, controlled by one way switch drawn through and including appropriate size of PVC casing capping with all accessoriese for surface wiring including 1.5 sqmm PVC insulated un shealthed copper cable multistrand conductor 1100 Volts grade for continuity earth wire connected to Each point and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick bakalite sheet cover complete all as specified and as directed.
All as per item No 137 here-in-before but for 3 pin 5 Amps Switch Socket point on independent board with 1.5 Sqmm. Earth wire complete all as specified and as directed.
Material and labour switch socket combination2 in 1 3 pin 5 Amps, 240 V Flush type, complete all as specified and as directed.
Supply and fixing switch piano type 5 Amp single pole one way. complete all as specified and as directed.
Supply and fixing ceiling rose surface backelite 65 x 50mm three terminal complete all as specified and as directed.
Supply and fixing LED tube light fitting 20 watt battens fittings nano diffuser technology to ensure minimum loss in light transmitted, zero mercury content green lighting solution with and incl 1X4 feet LED tube including necessary accessories and electric connection complete all as specified and as directed. Make: Philips Cat No-BN150W LED 20S-6500 PSE OD GR or equivalent model in Havells/Bajaj/C&S/CG
Supply and fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed. by Engr-in-charge
Supply and fixing MCB, single pole, 240 Volts, of 10KA capacity (6-32 Amps) Amps complete all as specified and as directed.
Supply and fixing MCB SPN, 40 to 63 Amps, 240 Volts , breaking capacity 10KA complete all as directed.
Supply and fixing MCB DB SPN (double door) 2Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.
Supply and fixing sub-main wiring (surface type) for main DB's to sub DB's with PVC (FRLS) insulated & unsheathed two runs of 2.5 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 1.5 sq mm PVC (FRLS) insulated & unsheathed copper conductor cable, 1100 Volt grade, with PVC casing & capping connected to common earth dolly as earth continuity conductor, drawn through PVC casing & capping carefully complete all as specified and as directed by the Engr-in-Charge. Note : Two runs of 2.5 sqmm and one run of 1.5 sqmm cable shall constitute one unit.
Supply and fixing LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.Make-Bajaj model No BRTFG 100W LED CRj/CG model No LSTP-90 CDL or equivalent in Havells/C&S/Philips
BSA/KOL/REV/25/2020-21 (B/R) Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. slabs ,lintel,chajja, fin , facia etc. 25 mm average thickness including tapering all edges, making square shoulders of cavities air and cleaning of exposed concrete surface of lightly picking materials by manual method including foreign materials , loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed upto 8 storey bldg.
Removing of concrete all around reinforcement bar upto 12 mm dia and over from behind the reinforcing bars average 25mm (but not less than 15mm air gap)by manual methods (using wire brushing ,chiselling etc) and applying chloride free rust removing chemical on rusting steel reinforcement bar and removing all rust from steel reinforcement bar by emery paper and cleaning the area throughly by water and allow it to dry and totally rust free of reinforcement bar all as complete as per manufacturer's instruction complete all as specified and as directed. upto 8 storey bldg. Make( Rust removing chemical ):- Reebaklens RR of FOSROC or quivalents solutions as listed
Material and labour for preparing existing reinforcement surface by brush and application two component epoxy zincrich primer on existing reinforcement surface of minimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2 and maximum coverage area 5.00 Sqm per litre complete all as specified and directed.upto 4 storey bldg.(INCL necessary scaffolding) Make- Nitozinc primer of FOSROC or equivalents chemical given in approved make list of PS.
Supply, materials and application of two component structural grade polymer modified reinstatement mortar of compressive strength, flexural strength shall not be less than 45 MPa at 28 days , 7MPa at 28 days respectively ( maximum coverage area 1.3 sqm per 25 kg pack @ 10 mm thickness) over a coat of epoxy Bonding agent on existing surface for strengthening of beams, columns & other structural elements of average thickness 25mm and morter shall be applied in layers n.exc 6mm thick in layers and including surface preparation and 10mm thick plaster CM(1:6) as per manufacturers instruction ccomplete all as specified and as directed. Note:- This item shall be execution where shuttering is not possible or small patch repairs of structural elements .Make (polymer modified reinstatement mortar):- Renderoc S2 of FOSROC or equivalent chemical given in approved make list of PS.
Supply and fixing iPowder coated aluminium sliding windows for three track with rubber gasket, stopper powder coated aluminium standard beads/glazing clips ,locking arrangement etc and aluminium frame of size 100 mmX25mmX3.00mm and shutter of section 20mm X40mm X3.00mm including one shutter of 4.8 thick plain glass and two shutter of stainless steel wire cloth, 0.63 mm dia of wire and average width of aperture 1.18 mm taking down old steel windows with necessary all fittings complete all as per manufacturer's instructions and complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing Powder coated aluminium door shutter fixed with rubber gasket, stopper, cleats, handles etc complete incl aluminium door styles of size 95 mm x 38 mm x 3.00 mm and aluminium door section of top, bottom and lock rail shutter frame of 95mm x 38mm x 3.00 incl both panels 4.8 mm thick frosted glass and taking down old door with necessary all fitting and all necessary fittings complete all as specified and as directed by the Engr-in-Charge.
Dismentling floor hearth or wall tiling including cement motor bedding incl backing, removing serviceable tiles to stone and rubbish off the premises complete all as specified and as directed.
Material and labour light shade Vitrified ceramic tiles 9-10 mm thick (Sqr/ rectangular) Polished, area of each tiles n.exc. 0.36sqm, in floors etc. set and jointed in neat cement slurry over and including a bedding layer of scread bed 15 mm thick iln CM 1:6 and pointed in white/colour cement to match complete all as specified and as directed.
Supply and fixing accoustic sound proofing wall/ceiling Panel (50 mm to100 mm) thick any size and shape screwed to studs/fixed, sound absorption ,fire resistance, thermal insulation fixing in plaster wall surface on (75mmx50mm timber stud at 600 mm centre) or 48mm stainless steel metal C studs and 52 mm sound blocker quilt SBQ2 (suspeneded cavity between studs) and sound proofing mat and repair of existing wall damp proof treatment with damp proof chemical complete all as specified and as directed.
Supply and laying 18 to 20 mm thick rubber flooring, any shape and size as approved by GE before incorporation in work, fixed in floor and making good to all corner and joints neatly complete all as specified and as directed.
Material and labour for suspended false ceilling system using chicogo metalic (E grid) exposed suspende system, grid section size 600mm x 600mm comprising of GI powder coated main runner of dimension 39 mm x 24mm x 0.80mm thick ( thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of Runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X 24mm x 0.8 mm thick wall angle 22.2mm x22.2mm x 0.65 mm thick ( thickness comprising of GI/0.35 + PPPCGS/0.3 mm & Weight of angle 0.70 kg for 3050 mm length) with and including 4mm thick HPSC ( High pressure steam cured) pre- primed, self embossed textured designer board, water resistant termite resistant, fire resistant for insulation and accustic purpose to be placed in the grid system duly suspended with 6 mm dia G I bars hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips (Wt- 0.007 Kg/clip) hold down clips (Wt - 0.0035 Kg/clip) with Provn of light fixture complete all as directed. Make- EVEREST/Gypsum/Saint gobain or other equivalent as approved. complete all as specified and as directed.
Material and labour brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Material and labour for 15 mm thick plastering on fair faces of brick wall in Cement mortar (1:6) surface finished even and fair complete all as specified and as directed.
Material and labour for preparing old wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paints complete all as specified and as directed.
Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.
Material and labour for 15mm thick plastering on faces of brick wall in Cement mortar (1:4) surface finished even and fair complete all as specified and as directed.
Material and labour for applying two coat acylic distemper over coat of putty on new plastered surfaces preparatory to distemper incl preparation of wall surfaces. complete all as specified and as directed.
BSA/KOL/REV/25/2020-21 (E/M) Material and labour for point wiring concealed type for one light/fan/call bell point controlled by One Way switche,with 1.5 sqmm PVC insulated unsheathed copper cable multistrand conductor 1100 volts grade (Red colour cable used for live connection, Black colour cable used for neutral connection and green cable used for earthing connection, controlled by one way switch drawn through and including appropriate size PVC conduit with all accessoriese for concealed wiring including 1.5 sqmm PVC insulated un shealthed copper cable multistrand conductor 1100 Volts grade for continuity earth wire connected to Each point and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick laminated bakalite sheet cover complete all as specified and as directed.
All as per item No 166 here-in-before but for 3 pin 5 Amps socket outlet on same board with 1.5 Sqmm cable. complete all as specified and as directed.
All as per item No 166 here-in-before but for 3 pin 5 Amps S/witch socket point on independent board with 1.5 Sqmm earth wire. complete all as specified and as directed.
All as per item No 166 here-in-before but for 5 pin 15 Amps switch socket combination on independent board with 2.5 Sqmm earth wire. complete all as specified and as directed.
Material and labour socket outlet 5 pin 5 Amps, flush type, 240 Volts, universal complete all as specified and as directed.
Material and labour switch socket combination 2 in 1, 6 Amps, 240 V Flush type, complete all as specified and as directed.
Material and labour switch socket combination 2 in 1, 5 pin 6/16 Amps,flush type, 240 Volts, complete all as specified and as directed.
Supply and fixing switch piano type 5 Amp single pole one way. complete all as specified and as directed.
Supply and fixing ceiling rose surface backelite 65 x 50mm three terminal complete all as specified and as directed.
Supply and fixing LED tube light fitting 20 watt battens fittings to ensure minimum loss in light transmitted, zero mercury content green lighting solution with and incl 1X4 feet LED tube including necessary accessories and electric connection complete all as specified and as directed. Make: Philips Cat No-BN150W LED 20S-6500 PSE OD GR or equivalent. model in Havells/CG/C&S/Bajaj
Supply and fixing recessed mounting luminaire LED 2X2, 27 Watt,230V, AC with full glow is a beautifully desined which is bound to delight the occupants with refreshing and comfortable and with necessary electric connection and complete all as specified and as directed. Make: Philips Cat No-RC38B G2 LED35S-6500 PSU OD WH or equivalent. model in Havells/CG/C&S/Bajaj
Supply and fixing ceiling fan of size 1400mm sweep, single phase heavy duty with their all accessories fixed properly on roof surfaces/ceiling including making hole to fixing 'S" hook including cutting of roof/ceiling finishing with cement plaster and making good to the distuberd surface of roof internal sides and two coats of distumber to match with the existing colour white/colour wash including connecting/testing complete all as specified and as directed. Make : Usha Model No: Striker or equivalent in Havells/Orient/CG
Supply and fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed by Engr-in-charge
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with BEE 3 star rating of capacity 1.5 TR complete all as specified and as directed.Make-Carrier model no CAS18DN3R30F0 or equivalent model in Voltas/Daikin/LG
Supply and fixing sub-main wiring (surface type) for main DB's to sub DB's with PVC (FR-LSH) insulated & unsheathed two runs of 4 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 2.5 sq mm PVC (FRL-SH) insulated & unsheathed copper conductor cable, 1100 Volt grade, with PVC casing & caping/conduit connected to common earth dolly as earth continuity conductor, drawn through PVC casing & capping carefully complete all as specified and as directed. Note : Two runs of 4 sqmm and one run of 2.5 sqmm cable shall constitute one unit.
Supply and fixing power supply unit consisting of starter with 20 Amps over ;load protection, MCB-20 Amps 10/25 A 3 pin combined socket including 6 modular sunkin box ,inner plate and top cover after and including taking down old one complete all as specified and as directed. Make:Crabtree or equivelent in Legrand/L&T
Material and labour framed brackets of angles or tees for fixing of outdoor unit of Split air conditioner including drilling, rivetting, welding as necessary and painting if necessary with one coat of red oxide primer and two coats of synthetic enamel paint complete all as specified and as directed.
DIPAK ENTERPRISE
SOVA ENTERPRISE
CHOWDHURY SMALL INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .