Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹25.9 L+₹2.0 L (8.31%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹27.9 L+₹4.0 L (16.7%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹31.2 L+₹7.2 L (30.1%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹29.1 L
EMD Value
₹58,144
Closing Date
19 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Mathew M Shepherd
GE (WEST) MATHURA
ADDN ALTN TO BUILDING NO. P 15, P 18 AND P 20 UNDER GE W MATHURA
2023_MES_619073_1
8300/1199/E8
Open Tender
Civil Works
Works
120 days
GE (WEST) MATHURA
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (WEST) MATHURA
₹58,144
Yes
29 Nov 2023
21 Sept 2023
26 Oct 2023
21 Sept 2023
19 Oct 2023
5 Oct 2023
Amount
M & L for Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks etc.
S&F powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S & F powder coated Anodised aluminium door section, aluminium sections weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws Anodise aluminium fitting such as including hinges 100 mm long (2 no) and suitable handle(2 No) complete all as specified and directed.
S & F powder coated aluminium sliding window three track with frame & two glass shutters using 4 mm thick glass tinted modi guard and one shutter with stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperture 1.61 mm using aluminium powder coated section aluminium cleat ,PVC track ,bearing, handle lock,rubber beading etc complete fittings as approved. Note:- Size of aluminium section shall be under- (i) Three track top and vertical - Jindal main-2010 section No 20621 or equivalent as approved by GE. (ii) Three track bottom - Jindal main - 2010 section No 20620 or equivalent as approved by GE. (iii) Shutter vertical section -Jindal main -2010 section 20604 or equivalent as approved by GE . (iv)Shutter top and bottom - Jindal main -2010 Section 20604 or equivalent as approved by GE. (v)Shutter vertical middle (interlock) - Jindal Main -2010 Section 20605 or equivalent as approved by GE.
S & F powder coated Anodised aluminium window and ventilator shutters side hung type without sash, aluminium sections weighing 0.55 kg/ m including necessary joining cleats, glazing clips rubber packing, anodised aluminium snap beading screws Anodise aluminium fitting such as peg stays 150 mm long (1 No ), including pag stay and hinges type B-21 100 mm long (2 No) and suitable handle (1 No) complete all as specified and directed.
S&F powder coated aluminium grill in windows,doors or ventilators of approved make complete all as specified and directed.
S & F 5mm thick coloured APP(Aluminium partition pannel) sheet using aluminium partition including joining cleats for fixing etc.(colour of sheet approved by GE)
S & F 5.50 mm thick frosted glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane.
S&F Sheet glass 5 mm thick in glazing to aluminium door, window & partition including pad, gasket complete all as specified and directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L in aluminium Motrice lock 4 levers and100 mm size for aluminium doors complete all as specified and directed.
S&F 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F door closer hydraulically regulated designation No. 3 universal type cast iron body suitable for door shutters of 851 to 1000mm in width of weight between 61 to 80 kg and fixed complete all as specified and directed.
S&F for double action floor spring hydraulically regululated made up of minimum 1.25mm thick aluminum sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Eng-in-charge.
S&F in repairs curtain rod, stainless steel of 25mm dia with fixing brackets stop rollers, knob etc fix complete all as specified and directed.
S&F GI lay in metal ceiling system of 600 x 600mm module which includes provides and fixing 'C' wall angle of size 20 x 30 x 20 mm of 0.5 mm thick prepainted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm c/c , suspending the main main C carrier os size 10 x 38 x 10 mm made of GI steel 0.7mm thick from the soffit with help of soffit cleat 37 x 27 x 25 x 1.6mm, rawl plugs of size 38 x 12 mm and C carrier suspension clip and main carrier bracket at 1000mm c/c. Inverted triangle shaped spring Tee having height of 24mm and width of 34 mm made of GI steel 0.45mm thick is then fixed to main C carrier and in direction to perpendicular to it at 600mm c/c with help of suspension brackets. Where ever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120gm/sqm(both side inclusive, fixing with clip in tiles into spring T with:-
GI metal ceiling lay in plain beveled edge global white colour tiles of size 600 x 600mm and 0.5mm thick with 25mm height, made of GI sheet having galvanizing of 100gm/sqm (Both side inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
GI metal ceiling lay in plain beveled edge global white colour tiles of size 600 x 600mm and 0.5mm thick with 25mm height, made of GI sheet having galvanizing of 100gm/sqm (Both side inclusive) and 20% perforation area with 1.8mm dia holes and having NRC of 0.5 electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed.
M&L for vitrified ceramic tiles light shade 10mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed bed in CM (1:4) complete all as specified and directed.
All as per item No 18.00 (here-in-before) above but as in skirting over 10mm thick backing coat in CM (1:3) complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) (1:2:4) type B1 using 20mm graded stone aggregate as in chajjas etc complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) (1:2:4) type B1 using 20mm graded stone aggregate as in beams, cantilevers, bressumers, lintels over 1.5 m span complete all as specified.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT MS bars of 5mm dia and upto 10mm dia as in stirrups and spacers cut to lengh bent to shape reqd incl cranking bending spirally for hooking for column and binding with MS annealed wire not less than 0.9mm dia complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc. for rough finished surface of concrete complete all as specified and directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 including water proofing compound on fair face of brick or concrete surface,finished even and smooth without using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound of approved complete all as specified and directed.
Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc. complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in CM (1:4) as on ceiling complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer including 1mm thick wall care putty prepartory to distemper complete all as specified and directed.
M&L preparation of new plastered surfaces and applying two coats of exterior weather coat and primer on walls all as specified.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old surface of walls and applying two coat of distemper oil emulsion distemper on wall incl applying a coat of wall care putty to achieve smooth finish to wall etc complete all as specified and directed.
M&L for complete removal and preparation of old painted surfaces of wall and applying two coat of exterior emulsion paint over a coat of primer complete all as specified and directed.
M&L for preparation of old treated surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick above or below ground level complete all as specified and directed.
M&L for 75mm thick cement concrete type C-2, (1:3:6) using 20mm graded stone aggregate as plinth protection and finished surface even and smooth without using extra cement complete all as specified and directed.
M&L 75 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for vitrified paving tiles (any colour) of size 30cm x 30cm x 10mm thick, with gray cement & pigment set, jointed and pointed in neat cement slurry in floors laid over and including 15mm screed bedding in cement mortar (1:4) complete all as specified and directed.
M&L for point wiring complete with 2.5sqmm single core FRLSH ISI marked PVC insulated cable with multi stranded copper conductor in and including PVC conduit 20mm dia and thickness not less than 1.5mm, ISI marked with all accessories for concealed conduit as directed at site including chase cutting for one light/fan point controlled by one switch including MS sheet sunken box concealed in wall duly painted inside with one coat of red oxide primer and two coats of black bituminous paint in out side with 3mm thick hylum brand bakelite sheet cover for fixing switches, sockets, regulators etc. alongwith 2.5 sqmm multi stranded FRLSH, PVC insulated copper cable as continuous earth connected to comman earth and earth dolly including making good the disturbed surfaces complete all as specified and directed.
All as per item No 43.00 (here-in-before) but for one 5 pin socket outlet 5amps point controlled by one switch on independent board.
All as per item No 43.00 (here-in-before) but for one 5 pin socket outlet 5amps point controlled by one switch on the same board with other switches.
M&L for Point wiring complete with 4 sqmm single core FRLSH PVC insulated cable with multi stranded copper condutor in and including PVC conduit 20mm dia and thickness not less than 1.5mm, ISI marked with all accessories for surface or concealed conduit as directed at site incl chase cutting for one light/fan point controlled by one one way switch including MS sheet sunken box concealed on wall duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint with 3mm thick hylum brand bakelite sheet cover for fixing switches, sockets, regulators etc. alongwith 4 sqmm multi stranded FRLSH, PVC insulaedcopper cable as continuous earth connected to common earth and earth dolly including making good the disturbed surfaces complete all as specified and as directed.
M&L for Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable drawn through and in existing surface / recessed PVC conduit and connecting incoming/outgoing electric connections and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable as earth conductor including taking down old unsv submain wiring and making good the disturbed surfaces complete all as specified and directed. Note: Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit of 32mm dia shall be measured and paid as one unit length.
S&F switch piano flush button single pole, one way 6 Amp 240 Volt complete all as specified and directed.
S&F switch piano flush button single pole, one way 16 Amp 240 Volt complete all as specified and directed.
S&F socket 6 amps 5 pin flush type, 230 volts complete all as specified and directed.
S&F socket out let, 6 pin 6 and 16 amps multi purpose 2 in 1 flush type 230 volt complete all as specified and directed.
S&F sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20A 240 Volt complete with one single pole MCB of cap 20/25 A, C series complete all as specified and directed.
S&F ceiling rose 63x30 mm three terminal, polycorbonate body complete all as specified and directed.
SS&F fan regulator electronic, five step type hum free suitable control speed of fan from 0 to 100% and connecting electrically all as required complete all as specified and directed.
S&F Angle/ batten holder polycorbonate type body suitable for batten fitting complete all as specified and directed.
Supply & fixing tube light fitting with surface and wall mounted decorative ultra slim round profile LED lighting fixture, 20 watt LED with entruded polycarbonate, environment friendly, energy efficient ready to use with polycarbonate diffuser & integrated electronic driver complete all as specified and directed.
Supply & fixing bulk head decorative LED light fitting of 10 W, IP - 66, environmental friendly, ultra modern, energy saving, surface mounted complete all as specified and as directed.
Supply & fixing tube light fitting with surface and wall mounted decorative ultra slim round profile LED lighting fixture, 10 watt LED with entruded polycarbonate, environment friendly, energy efficient ready to use with polycarbonate diffuser & integrated electronic driver complete all as specified and directed.
Supply & fixing security light with LED street light, 30 Watt, IP - 66, Impact resistance - IK07, colour temp- 5700 K, Class-I in pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, separate optical and control gear compartment & top opening for easy maintenance. Polyster powder coated grey after phosphochromate treatment High efficiency long life LED modules with SMD LED package mounted on MCPCB. Lumen efficacy of LED >110 lm/W with PC lens to ensure better uniformity of light distribution. Powered by Built-in, Potted electronic LED driver (SMPS based constant current supply) with lower THD, Output Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13 alongwith arm with single arm bracket OD 58 mm (max) with clamp, nut, bolts etc mounted on wall complete in all respect complete all as specified and directed.
Supply & fixing ceiling light with 40W Watt, 6500 K, slim LED panel 2' x 2' LED panel for recessed on ceiling) dust-free installation with high brightness LEDs for glare-free homogenous illumination with driver and all other connected accessories complete all as specified and directed.
Supply & fixing sheet metal enclosure MCB distribution board triple pole & neutral 415 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Supply & fixing sheet metal enclosure MCB distribution board Single Pole & Neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Supply & fixing of MCB, 415 Volt, 10 KA, 4 Pole, 100 Amps, C series complete all as specified and directed.
Supply & fixing of MCB DP, 240 Volt, 10 KA, 40 Amps, C series complete all as specified and directed.
Supply & fixing of MCB SPN, 240 Volt, 10 KA, 40 Amps, C series complete all as specified and directed.
Supply & fixing of MCB SPN, 240 Volt, 10 KA, 63 Amps, C series complete all as specified and directed.
Supply & fixing of MCB single pole 240 volt any rating from 6 to 32 amps, C series with rupturing capacity 10 KA complete all as specified and directed.
Supply and fixing BLDC ceiling fans, 5 star rated by Bureau of energy with service value of not less than 8.40, (26W±10%) with or without remote, with rated speed 350 Rev per min, air delivery 220 Cum/min complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200 mm sweep, suitable for single phase supply complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt, connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI pipe 20mm light grade for water filling including 15x20mm reducer socket funnel wire mesh, RCC cover with concrete 1:2:4 using 8 mm# bar@100 mm c/c both ways ,PCC chamber pit with PCC (1:3:6) type C-2 and excavation and earth work,disposal of suplus spoil to a dstance not exceeding 50mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) complete all as specified. Note :- The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level.
Supply & fixing PVC flat twin core of size 10 Sqmm complete all as specified and directed.
S&F LED bulb of capacity 10/12 watts not less than 700 lumens output at 6500K colour temp, complete all as specified and directed.
S&F Exhaust fan 300mm sweep, heavy duty, four blade, double ball bearing, 1400 RPM, minimum air delivery dishcarge 1710 CMH suitable for SP 230/250V, 50 Hz AC Supply with protective bird guard with louver shutters including grouting of frame in wall and connecting with and including 3 run 0.5 Sqmm single core, PVC insulated but sheathered FRLSH multistranded copper conductors cable from ceiling rose to exhaust fan complete all as specified and directed.
KASHI NATH BANWARI LAL
Ms Kamal Kant Agarwal
Ahmed constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .