Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹6.4 LAccepted-AOC NULL | L 1 | Accepted-AOC L1 | |
| 2 | L 2₹6.4 L+₹971.80 (0.15%)Rejected-Finance | L 2 | Rejected-Finance L 2 | |
| 3 | L 3₹6.6 L+₹16,382 (2.55%)Rejected-Finance | L 3 | Rejected-Finance L 3 | |
| 4 | L 4₹6.7 L+₹26,130 (4.07%)Rejected-Finance D 981 ASHOK NAGAR GALI NO 12 SHAHDARA DELHI 32 | SHAHDARA | DELHI | 110031 | L 4 | Rejected-Finance L 4 | |
| 5 | L 5₹7.1 L+₹68,664 (10.7%)Rejected-Finance | L 5 | Rejected-Finance L 5 |
Tender Value
₹7.6 L
EMD Value
₹15,300
Closing Date
28 Mar 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony New Delhi 110024
Special Repair of double storied block on back side of Lajpat Nagar colony hospital in Ward no. 57-S Central Zone. Sub Head Improvement of EI Fans and Compound Lights..
2022_SDMC_111322_1
EE(Elect.)/CNZ/2021-22/54-01
Open Tender
Electrical Works
Item Rate
60 days
C-Block, Defence Colony New Delhi
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹15,300
14 Dec 2024
26 Mar 2022
29 Mar 2022
26 Mar 2022
28 Mar 2022
26 Mar 2022
30 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cableetc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 5/6 &15/16A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way (4 + 24), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 Amps
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole.
Supplying and fixing following rating ,double pole,240 volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required 63 amps
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 8 module (125mm x125 mm)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Up to 35 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size on wall surface as required. Up to 35 sqmm
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
S.I.T.C of LED Tube type Luminaire 20W rating complete with Extruded Aluminium Batten prewired with high efficient LED with the following: (a) Total System wattage 20 watt +/- 5% (b) Luminous Efficacy Lumens/watt >=95 (c) power factor >= 0.95
Supply,installation,testing & commissioning of single phase monoblock pump set complete with all accessories workable on 240/415 volts,50 Hz AC supply.(a) 1 HP (0.75 KW) Single phase pump set,head from 12-30 mtr. suction and delivery 25X25 mm.
Supply of 2 x 6 Sqmm size of XLPE insulated and PVC sheathed Al. Conductor Armored cable confirming to 7098 as reqd.
Supply of 4 x 25 Sqmm size of XLPE insulated and PVC sheathed Al. Conductor Armored cable confirming to 7098 as reqd.
Supply of 12'' ( 300 mm )sweep 1400 RPM exhaust fan heavy duty complete with shutter,blade etc as required.
SITC of 60 W LED Flood light luminiare fitted with lens ,made of pressure die cast aluminium housing & toughened glass cover complete with following specification as required.(b) Total system wattage=60 watt+/-5%.(d) Luminiaire effiency >=100Lm/w.(e) power factor >=0.95.(f) Protection class -IP-66
P & F of Hot Press Sheet Moulded Compound (SMC),fire retardant (Temp. resistanceup to 200 deg.C),IP-55 weatherproof pole box of inner dimension 200 mmx160 mmx98 mm complete with suitable arrangement for fixing of 2 nos.of 6 to 32 amp single pole MCB & 63 Amp. double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN channel with 2 Nos. of MS clamps with SS back plate of suitable size with danger monogram & property printed on the cover etc. as required.
A.J ENTERPRISES
SETH CONSTRUCTIONS
SANGWAN ELECTRICALS
Grover Electricals
The Electrician
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .