| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder. Hence Accepted | |
| 2 | L2₹19.2 L+₹1.2 L (6.53%)Rejected-Finance D 60 BRINDAVAN NAGAR CIVIL AERODROME POST COIMBATORE 641014 | COIMBATORE | COIMBATORE | TAMIL NADU | 641014 | L2 | Rejected-Finance L2 bidder. Hence Rejected | |
| 3 | L3₹19.4 L+₹1.4 L (7.83%)Rejected-Finance | L3 | Rejected-Finance L3 bidder. Hence Rejected | |
| 4 | L4₹20.5 L+₹2.5 L (14.1%)Rejected-Finance 256A BHOLANATH NAGAR STREET NO 2 SHAHDARA NEAR GEETHA BHAWAN SHAHDARA EAST DELHI DELHI 110032 | SHAHDARA | DELHI | 110032 | L4 | Rejected-Finance L4 bidder. Hence Rejected | |
| 5 | L5₹22.5 L+₹4.5 L (25.1%)Rejected-Finance 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | L5 | Rejected-Finance L5 bidder. Hence Rejected |
Tender Value
₹23.2 L
EMD Value
₹46,450
Closing Date
16 Aug 2023, 6:00 pmClosed
AGM(E-E), Madurai Airport
Asst. General Manager (E-E)
ARMO Works of EandM Installations during 2023 2024. SH Miscellaneous and unforeseen electrical works for Ground Lighting Facilities of Madurai Airport
2023_AAI_157872_1
AAI/MDU/E-E/MDU-379/NIT-06/23
Open Tender
Electrical Works
Works
90 days
Operational area
Refer Tender Document
18 documents required · 18 mandatory
₹1,180
₹46,450
4 Oct 2023
27 Jul 2023
18 Aug 2023
27 Jul 2023
16 Aug 2023
27 Jul 2023
27 Jul 2023 - 14 Aug 2023
Amount
Supply of 1C X6 Sqmm, 5 KV grade single core, stranded copper conductor PVC insulated and PVC sheathed ,unarmoured ,underground unscreened ,Anti-rodent & Anti-termite treated Airfield Lighting Cable generally confirming to IS 1554 Part II with upto date amendments as required.
Supply of 1C X16 Sqmm, 5 KV grade single core, stranded copper conductor PVC insulated and PVC sheathed ,unarmoured ,underground unscreened ,Anti-rodent & Anti-termite treated Airfield Lighting Cable generally confirming to IS 1554 Part II with upto date amendments as required.
Supply of XLPE insulated PVC sheathed, Armoured Aluminium conductor power cable of 1.1 KV grade of following size etc as per IS 7098 part I 1988 with uptodate amendments etc complete as required. 3C X 25Sq.mm
Supply of series isolating transformer of rating 200W, 20A/6.6A of 5KV grade suitable for Runway light fittings etc as per particular specifications.
Supply of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting etc. OD-63 mm & ID-51mm nominal
Laying of 63 mm dia (OD-63mm & ID-51 mm nominal) DWC HDPE pipe/50mm dia GI Pipe direct in ground (75 cm below ground level) including cutting & jointing in all type of soil/hard rock/gravel/bitumen road including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required.
Supply of 16 Sq mm, 5 KV grade dry type plug and receptacle of type I , class B primary connector kit with field attachment and suitable for 5KV grade single core copper conductor,PVC insulated PVC sheathed AFL cable complete as required .
Supply of 6 Sq mm, 5 KV grade dry type plug and receptacle of type I , class B primary connector kit with field attachment and suitable for 5KV grade single core copper conductor,PVC insulated PVC sheathed AFL cable complete as required.
Making Field connections by crimping following sizes of plug & receptacle with the existing PVC copper conductor ,PVC insulated,PVC sheathed cable including filling the gap with water sealent material appplying HT insulation tape ,over which PVC tape etc as required 16 Sqmm
Making Field connections by crimping following sizes of plug & receptacle with the existing PVC copper conductor ,PVC insulated,PVC sheathed cable including filling the gap with water sealent material appplying HT insulation tape ,over which PVC tape etc as required. 6 Sqmm
Installation of 450mm CI transformer housing box with a base concrete of 1:3:6 of size 630X630X 100 mm thick, all round concrete of 1:2:4 ,150 mm thick top sloped with 1:2:4 cement concrete including excavation, disposal of material within 20 mtr lead. providing and fixing 300 mm long 15 mm dia "B" class GI pipe with checknut for drainage of water .complete as required.
Supply & Fixing of 6mm thick M.S. powder coated cover plate suitable for 330mm dia CI transformer housing box having 6nos of M10 tapped holes. Including Providing rubber gaskets suitable for 330mm dia CI transformer housing box.
Supply of M10 Size stainless steel bolts of 25mm length with spring & plain washers.
Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade / 5KV grade single core/two core AFL cable of size not exceeding 35Sqmm in the existing RCC/ HUME/METAL/GI/HDPE/DWC pipe etc. complete as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required.
providing and laying earth connection from earth electrode with 6 SWG dia G.I wire in 15mm dia G.I pipe in 30cm depth from earth electrode including connection with G.I. thimble excavation and re-filling etc. as required.
Providing and fixing 6 SWG G.I. wire on surface or in recess for loop earthing as required.
Drilling suitable horizontal bore across runway/taxiway/road/pavement and supplying & inserting 110mm dia PLB HDPE pipe in the bore along with required fittings including providing pulling rope through the pipe.
Providing and laying in position cement concrete 1:3:6 (1cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) of size 1Mtr x 1Mtr with an average thickness of 100mm around the Transformer housing Boxes /Earth pit chambers including top sloping the protruded portion of CI box/Earth pits with graded surface. This job also include Surface dressing, leveling ,watering, ramming, and finishing the surface as required.
providing masonry enclosure with cover plate having locking arrangement (Size of 300mm X 300mm) etc. as required.
Supply, Installation, Testing and commissioning of Three Phase Surge Protection Device (SPD) having 50KA (10/350 micro seconds) rating with limiting voltage of 1.5 KV, response time ≤ 100 ns to be installed in parallel at the mains power entry point & shall be of replaceable modular type including copper wire 16 sq.mm 12 mtrs. for connecting surge protection device in parallel to the busbar of the main electrical panel, 63 amp 3 phase MCB 4 pole with enclosure along with all accessories as required for installing as per tender specifications.
C P MONCHESTER ELECTRICALS
surbhi association
CREATIVE TRADING CO
CENTRE TAP ENGINEERING
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .