| 1 | L1₹40.1 LAccepted-AOC 77 DR ZAKIR HUSAIN WARD NEAR GAZI MASJID NAI BASTI GOHALPUR JABALPUR NAI BASTI GOHALPUR JABALPUR MADHYA PRADESH 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.8 L+₹2.7 L (6.67%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹47.8 L+₹7.7 L (19.2%)Rejected-Finance 5 36 ANJALIVILAI PADMANABHPURAM THUCKALAY KANYAKUMARI DIST TAMIL NADU 629175 | KANNIYAKUMARI | TAMIL NADU | 629175 | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
Closing Date
19 Jul 2021, 3:30 pmClosed
Asst.Gen.Manager(E-E)
O/o AGM(E-E), Coimbatore International Airport, Coimbatore-641014.
ARMO of E and M Installations at Coimbatore International Airport for the year 2021_22 and 2022_23. SH_ Comprehensive Maintenance of Split AC Units and Water Coolers Cum fountains at Coimbatore International Airport.
2021_AAI_75445_1
AAI/CBIA/ENGG(E)/CMCAC/2021-22
Open Tender
Electrical Works
Works
730 days
Coimbatore International Airport
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,180
Exempted
9 May 2022
12 Jul 2021
20 Jul 2021
12 Jul 2021
19 Jul 2021
12 Jul 2021
12 Jul 2021 - 16 Jul 2021
Amount
SH : I FOR THE FIRST YEAR ( 2021-22) Annual comprehensive Maintenance of following air-conditioners of all makes of following capacity at different locations including providing all necessary consumables and spares complete as required as per special condition/technical specification including CMC of Voltage stabilizers & timers, wherever connected etc as required. More than 6 years old AC units
1.0 Ton Window/ Split AC Units
1.5/ 2.0 Ton Window/Split / Cassette AC Unit
3.0 / 4.0 Ton Split / Cassette / Floor mounting/ductable AC Unit
Annual comprehensive Maintenance of following air-conditioners of all makes of following capacity at different locations including providing all necessary consumables and spares complete as required as per special condition/technical Specification, including CMC of Voltage stabilizers & timers, wherever connected etc as required.
1.0 Ton Window/ Split AC Units
1.5/ 2.0 Ton Window/Split / Cassette AC Unit
3.0 / 4.0 Ton Split / Cassette / Floor mounting/ductable AC Unit
5.5 TR walk in cooler ( Cargo )
11 TR Ductable AC units
16.5 TR Ductable AC units
Annual comprehensive Maintenance of Water Coolers of all makes of capacity upto 150 Ltr at different locations including providing all necessary consumables and spare complete as required as per special condition/technical specification etc as required.
Dismantling and re-installation of following type split type AC units up to 4 mtrs refrigerant piping including mounting of indoor and out door units, drain piping arrangements, charging of refrigerant gas, insulation of refrigerant piping with extended polythylene / PVC piping etc. complete as required
1.0/1.5 Ton/ 2 Ton Split AC Units
3/4 Ton Split/ Cassette / Floor mounting AC Units
All inclusive Comprehensive maintenance contract of Drinking Water fountain system installed at Coimbatore Airport including attending all breakdowns, carrying out preventive maintenance checks and servicing, repairing/replacing all components of the system as per the scope of work etc as per technical specification complete as required.
Supply of extra copper pipe line suitable for 1.0TR, 1.5TR, 2.0TR,3TR & 4.0TR AC units including providing insulation control cable etc., complete as required.
3/8" and 1/2" Copper pipe line
3/8" and 5/8" Copper pipe line
1/4" and 1/2" Copper pipe line
SH: II FOR THE SECOND YEAR ( 2022-23) Annual comprehensive Maintenance of following air-conditioners of all makes of following capacity at different locations including providing all necessary consumables and spares complete as required as per special condition/technical specification including CMC of Voltage stabilizers & timers, wherever connected etc as required. More than 6 years old AC units
1.0 Ton Window/ Split AC Units
1.5/ 2.0 Ton Window/Split / Cassette AC Unit
3.0 / 4.0 Ton Split / Cassette / Floor mounting/ductable AC Unit
Annual comprehensive Maintenance of following air-conditioners of all makes of following capacity at different locations including providing all necessary consumables and spares complete as required as per special condition/technical Specification, including CMC of Voltage stabilizers & timers, wherever connected etc as required.
1.0 Ton Window/ Split AC Units
1.5/ 2.0 Ton Window/Split / Cassette AC Unit
3.0 / 4.0 Ton Split / Cassette / Floor mounting/ductable AC Unit
5.5 TR walk in cooler ( Cargo )
11 TR Ductable AC units
16.5 TR Ductable AC units
Annual comprehensive Maintenance of Water Coolers of all makes of capacity upto 150 Ltr at different locations including providing all necessary consumables and spare complete as required as per special condition/technical specification etc as required.
Dismantling and re-installation of following type split type AC units up to 4 mtrs refrigerant piping including mounting of indoor and out door units, drain piping arrangements, charging of refrigerant gas, insulation of refrigerant piping with extended polythylene / PVC piping etc. complete as required
1.0/1.5 Ton/ 2 Ton Split AC Units
3/4 Ton Split/ Cassette / Floor mounting AC Units
All inclusive Comprehensive maintenance contract of Drinking Water fountain system installed at Coimbatore Airport including attending all breakdowns, carrying out preventive maintenance checks and servicing, repairing/replacing all components of the system as per the scope of work etc as per technical specification complete as required.
Supply of extra copper pipe line suitable for 1.0TR, 1.5TR, 2.0TR,3TR & 4.0TR AC units including providing insulation control cable etc., complete as required.
3/8" and 1/2" Copper pipe line
3/8" and 5/8" Copper pipe line
1/4" and 1/2" Copper pipe line
Job Contract for providing regular Operation & Maintenance of Split Ac Units, Cassette Ac units, Tower AC units, Ductable AC units, Water fountain & Water Coolers installed in Terminal Building and ancillary buildings in general shift (2 skilled, 1 Un skilled), as per the special conditions /technical specification and as per the instructions of the Engineer-in-Charge Note: If your quote for this item is lesser than the monthly minimum wages given in tender document page no.177, then your tender will be rejected in the CPP portal itself and your tender will not be considered for further financial evaluation to assess the L1 Tender.
GENIUS AIRCON PRIVATE LIMITED
RAM ENGINEERING GROUPS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .