Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.4 CrAccepted-AOC DADRA AND NAGAR HAVELI DN | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396193 | ₹83.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹85.2 CrRejected-AOC | ₹85.2 Cr | L2 | Rejected-AOC L2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹59.4 Cr
EMD Value
₹69.4 L
Closing Date
9 Jan 2023, 12:00 pmClosed
Executive Engineer, Project Cell, PWD, DNH Silvass
PWD Campus Block No.I,DNH,Silvassa
Construction of Nursing College and Allied buildings at Dadra and Nagar Haveli. (3rd Call)
2022_UTDNH_6249_1
E-TENDER NOTICE NO.40 OF 2022-23 (Bldg)
Open Tender
Civil Works - Buildings
730 days
UT OF DNH
As per NIT refer
3 documents required · 3 mandatory
₹5,000
Executive Engineer, Project Cell, PWD, DNH Silvass
₹69.4 L
Silvassa
18 Mar 2023
20 Dec 2022
9 Jan 2023
20 Dec 2022
9 Jan 2023
20 Dec 2022
27 Dec 2022
Amount
CIVIL WORKS Sec.1.0 Earth work Providing material, labour, machinery for Excavation of foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth and back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting.
Providing material, labour for Excavation of foundation from 1.5 mt to 3.0 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth and back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting.
Providing material, labour for Excavation of foundation from 3.0 mt to 5.0 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth and back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by engineer in charge. - Any type of soil or rock not requiring Blasting.
Providing material, labour for Excavation of foundation from 5.0 mt to 7.0 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth and back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting.
Providing material, labour for Disposing off the un-used excavated stuff (black cotton soil, debries, of above items for all lead and lift/ depth outside the campus at non objectional place or as directed by Engineer in charge.
Providing material, labour for Filling in plinth with sand under floors including watering ramming, consolidating and dressing etc complete as directed by Engineer in charge.
Providing material and labour for injecting Chemical emulsion for PRE - CONSTRUCTIONAL anti-termite treatment and creating a chemical barrier on the top surface of plinth filling, inside junction of wall and floor, on top of damp proof course (DPC) or on masonry at level of plinth filling as per IS 6313 (Part-2)-1981 using chemical like chloropyripos emulsifiable, Biflex TC, lindane (IS 8944-1978) 20EC mixed with water in 1:19 ratio (1 liter chemical : 19 liters of water). The emulsion shall mentioned below, all as per specification and directions of Engineer-in-charge. Plinth area in plan at GF shall only be measured (for akk below specified steps) and paid. A guarantee bond of 10 years shall be furnished. A1) Bottom surface and the sides of the excavation made for masonry foundations at the rate of 4 liters/sqm (wherever applicable) A2) At the rate of 7.5 liter/ sqm to the backfill at the depth of 500mm below the original ground level. The soil in the immediate contact with the vertical surface of RCC column/ Masonry shall be treated. B) Top surface of the plinth filling including damp proof courses at the rate of 5 liter/sqm of internal plinth area etc. complete. C) At the rate of 7.5 liter/ sqm to the internal vertical surface from original Ground level to top of the earth filled in the plinth. D) At the rate of 7.5 liter/ sqm to the external vertical surface below finished Ground level to the full depth of the filling complete. E) 1 liter / linear meter along the junction of wall and floor at all stages.
Providing material and labour for Boring holes of 300mm dia upto 3.5 m deep in ordinary soil (for cast in situ piles) and getting out the soil and disposal of the surplus excavated soil within a lead of 1.0 Km with in the campus/ out side the campus as directed by Engineer in charge.
Providing material and labour for Felling trees of the girth beyond 30 cm and upto and 60 cm (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material as directed by Engineer in charge.
Providing material and labour for Felling trees of the girth beyond 60 cm and upto and 120 cm (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material as directed by Engineer in charge.
Sec: 2.0 PCC & RCC works Providing material and labour for laying Autoclave Aerated Concrete Block chips/ bats cement concrete in 1:4:8 (1 Cement : 4 Coarse Sand : 8 graded Autoclave Aerated Concrete Block chips/ bats) for sunk filling grade including compacting, finishing, curing etc. complete as directed by engineer in charge.
Providing material and labour for laying Plain cement concrete 1:3:6 (1- Cement : 3- Coarse sand : 6- crushed stone aggregates 20 mm nominal size) in Foundation and Plinth including cost of formwork, compacting, finishing, curing etc complete for all level, all height/ depth as directed by engineer in charge.
Providing material and labour for laying Plain cement concrete M15 in Foundation and Plinth including cost of formwork, compacting, finishing, curing etc complete for all level, all height/ depth as directed by engineer in charge.
Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding (with 18 SWG -1.22 mm GI wire) and placing in position complete for all floors, all levels, all heights/ depth complete as per drawings, specifications and direction of Engineer in Charge.
Providing material and labour for laying controlled cement concrete M-20 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work for all elements, all floors, any heights/ depths, any lead and lift including cost of formwork, compacting, finishing, curing but excluding the cost of reinforcement etc complete as directed by engineer in charge.
Providing material and labour for laying controlled cement concrete M-25 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work for all elements, all floors, any heights/ depths, any lead and lift including cost of formwork, compacting, finishing, curing but excluding the cost of reinforcement etc complete as directed by engineer in charge.
Providing material and labour for laying in position Ready Mixed M-20 grade concrete for reinforced cement conctere Grade slab work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere Pile work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere Columns, Pillars posts, Mullion, struts work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere Beams, Lintels, Runner, Girders, pile-cap work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere Slabs, staircase, landing, shelves, chhaja, cantilever work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere any type of wall work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere Foundations, footings,Base of columns and Mass concrete work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere Columns, Pillars posts, struts work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere Beams, Girders work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere any type of wall work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-35 grade concrete for reinforced cement conctere Columns, Pillars posts, struts work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-35 grade concrete for reinforced cement conctere any type of wall work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for fixing in expansion joint 100 mm thick SIL FLEX (Capcell HD 100) expansion joint board of best quality and approved make including cutting to required size and shape for all floors, all height etc complete as directed by Engineer In charge.
Providing material and labour for fixing 50 mm thick expansion joint by hydro cell semi rigid UV resistance with high performance laminated closed cell polythene foam joint filler in sheet foam at all floors, any lead and lift etc complete as directed by Engineer In charge.
Providing material and labour for filling the expansion joint by Thioflex 600 polymer or equivalent sealant confirm to BS 4254-1983 as per required shade and manufactured specification by making groove of 50 mm x 12.5 mm lather by cutting or by repairing groove and removing mortar drop or any other foreign materials including applying primer and filling required size (oversize of joint PU foam) etc complete for all floor all height as directed by Engineer in charge.
Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes from 25 to 50mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency.
Providing material and labour for filling 25 mm thick joint wiht elastomeric joint sealant two component, high performance polysulfide formulation conforming to BS:4254 and ASTM C 920 having weathering resistance to ultra-violet rays and shall exhibit shore A hardness of 25 and have movement accommodation factor 25% including using of compatible primer of approved standard for at all floors, any lead and lift etc complete as directed by Engineer In charge.
Providing material and labour for fixing in position PVC pipe sleeves of 50mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location).
Providing material and labour for fixing in position PVC pipe sleeves of 75mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location).
Providing material and labour for fixing in position PVC pipe sleeves of 110mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location).
Providing material and labour for fixing in position PVC pipe sleeves of 160mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location).
Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes from 51 to 77mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency.
Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes from 77 to 102mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency.
Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes from 102 to 125mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency.
Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) holes from 125 to 152mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency.
Chemical Anchor: Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 10mm and depth 150mm as per manufacturer/ structural consultant's specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item. Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge.
Chemical Anchor: Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 12mm and depth 180mm as per manufacturer/ structural consultant's specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item. Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge.
Chemical Anchor: Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 16mm and depth 240mm as per manufacturer/ structural consultant's specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item. Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge.
Mechanical Anchor : Providing material and labour for drilling, cleaning hole and fixing mechanical anchor of size 10 X 120 of approved make and suitable for fastenings both on concrete & masonary/aerated blocks. Anchor comprises of 10 mm diameter Polyamide PA 6 grade sleeve and of 7 mm diameter double threaded 6.8 grade Hex head double threaded screw made of carbon steel galvanized to minimum 5 microns. Fixing methodology shall be followed as per manufacturer’s guidelines. for all floors, all height as directed by engineer in charge.
Providing material and labour for fixing of expansion joint system for 100mm wide gap of approved make related with floor location as per drawings and direction of Engineer-In-Charge. The joints system shall be of extruded aluminum base members, self aligning/ self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor/ floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and match with finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates/ moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design. (Material shall conform to ASTM 6063). Rate shall be inclusive of stone fixing in between the system as per drawing. Cost of stone shall be paid in relevant tender item. Expansion joint system shall be as approved for all floor all level including scafolding etc complete as directed by engineer in charge.
Providing material and labour for fixing of expansion joint system for 100mm wide gap of approved make related with internal wall and ceiling joint location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning/ centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner/ ceiling application, with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Rate shall be inclusive of polyester powder coating of approved shade and make. Expansion joint system shall be as approved for all floor all level including scafolding etc complete as dircted by Engineer in charge.
Providing material and labour for fixing of expansion joint system for 100mm wide gap of approved make related with External wall joint location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning/ centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner, with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Rate shall be inclusive of polyester powder coating of approved shade and make. Expansion joint system shall be as approved for all floor all level including scafolding etc complete as dircted by Engineer in charge.
Providing material and labour for fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut Powder coated aluminium sheet 2.5mm thick (minimumthickness of powder coating 50 micron) and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge.
Sec.3.0 Centering & Form works Providing material and labour for formwork for exposed concrete surfaces (Only extra addition cost on normal shutering) (vertical or horizontal surface) in smooth finish, desired pattern and size as per drawing and specifications, including rendering with white cement and grey cement, using laminated shuttering plywood, for vertical and steel or laminated plywood shuttering for horizontal surfaces for all types RCC elements like slabs, walls, columns, beams, folded staircase (all sides), sill, coping, lintels, jambs, beam hunching, vertical fins, pardi etc. including neat cleaning the exposed concrete surface, as directed by the engineer-in-charge. In case of round window opening in exposed RCC wall, for payment of expose shuttering opening cutout shall not be deducted (both side). Rate shall be applicable for all floors, all levels, all places and all shapes. The contractor shall submit shuttering pattern including tie-rod hole position based on architectural conceptual drawings. (Same kind of shuttering material should be only used for standard and residual sizes.)
Sec.4.0 Masonry works Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth/ Upto basement Floor in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for Ground Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for First Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for Second Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for Third Floor at any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for Fourth Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for Fifth Floor at any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in foundation and plinth/ Upto Basement Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for Ground Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for First Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for Second Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for Third Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for Fourth Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for Fifth Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying of hollow concrete block masonry for jali work madeout from M20 grade 200mm thick hollow block of different size to cerate a pattern as per drawing confirming to IS 2185 Part I grade A (7.0), shape of hollow part shall be round, square or rectangle. Jali wall shall be constructed in cement mortar 1:2 (1 cement : 2 coarse sand) by providing 2 no of 6 mm dia. GI bar at each layer vertically as well as horizontally. GI wire/ rod shall be anchored in adjoining surface with quick fix chemical including roughening, cleaning, fixing and finishing/ rendering in grey and white cement sand mortar 1:1 in the line and level and in pattern including finishing, curing at all heights with necessary scaffolding etc complete as per the drawing and direction of Engineer in charge. Note: Payment should as per actual area of jali made out of hollow block, no deduction of hollow gap of block should be consider for payment.
Providing material and labour for fixing 190mm x 190 mm x 80 mm glass bricks of approved make and design with white CM 1:2 ( 1 white cement : 2 sand). Two numbers of 5 mm thick GI wires to be passed through PVC spacers in each joint horizontal as well as vertical by drilling holes in surrounding surface (brick or RCC) and filling the same with Hilti or equivalent chemical (rebarring). The PVC concealed spacer (with provision for passing the 2 no. GI wires in horizontal and vertical direction) shall be provided to maintain grooves/spaces for GI wire and white cement mortar at the junction of two glass bricks including curing. The sample of the glass brick shall be got approved by Architect. The glass bricks shall be fixed with placing GI wires vertically as well as horizontally after passing through the spacer and having minimum lap length of + 200 mm as per the site conditions at all the places, all heights, all level and in all shapes, etc. complete, as per drawing and as directed by Engineer-in-charge. Joints along the periphery of glass bricks shall be filled with approved make and color weather silicone sealant of DOW corning 789 or equivalent.
SEC:5 Doors and Windows work ALUMINIUM WORKS - Providing material and labour for fixing in position frames/ shutter for any type of aluminium work for any type of door, window, partition, fixed louvers, made out of any type of aluminium sections of approved make having minimum 50 micron pure polyester powder coating of approved shade, texture & colour of approved make for all floors/ all levels/ all heights/ all shapes/ all sizes including cutting, bending, crimping, fabricating in best workmanship manner etc as per the drawing, specification and as directed by Architect or Engineer-in-Charge. Contractor shall prepare shop drawing based on concept drawing and get approved from the consultants before procurement of material. All loose material shall be approved. Mockup of one/two window shall be executed as per approved shop drawing with all hardware. Work shall carried out as per the approved shop drawings, approved mock-up and approved sample. Actual weight of installed Aluminium sections which are visible shall only be measured and shall be considered for the payment. Contractor shall provide guarantee for stability, water tightness etc for 12 months after defects liability period. Rate shall be inclusive of providing aluminium sections, cutting, fabrication, errection and fixing to the best workmanship manner, including 1) Sheet metal screws and casted solid aluminum corner cleats fixed with external byttins with a spring for rapid and secure joint assembly for casement and sliding shutter and frame; 2) Glazing clips for receiving infill panel; 3) Best quality wool pile where ever shutter touches the frame and compatible microwave cured EPDM rubber; 4) Dash Anchor fasteners of HILTI HRDUGT or equivalent for fixing the frame assembly to the RCC or masonry surfaces. Minimum 1 anchor fastener shall be used for every 600 mm length of section for stability of frame. 5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4mm thick solid aluminium corner cleat of full thickness of section for connecting style and horizontal rails; 6) providing and fixing packing at every 600mm c/c of average 6 mm compact sheet of width (equal to section width less 30mm for backer rod and sealant); 7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker rod of avg. 10 mm thickness of approved make and color and then sealing the remaining gap with neutral grade G/M (Glazed & Metal) weather silicon sealant of approved make and color. 8) Termite treated seasoned teak wood as infill material to installe hardware in door shutter and frame as and when required but excluding. 1) necessary hardware; 2) Glazing or Infill material.
Providing material and labour for fixing 6mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.
Providing material and labour for fixing 8mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.
Providing material and labour for fixing 10mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.
Providing material and labour for fixing 12mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.
Providing material and labour for process charges of Frosting the glass (any thickness of glass) as per drawing and as directed by engineer in charge. Rate shall be for only for extra cost of Forsting on Glass for all floor, all height all level.
Providing material and labour for fixing 6mm thick Compact Sheet of any size, any shape, any color, any texture of approved make and as per approved sample (approved by architect). Compact sheet shall be fixed in aluminium frame and shutter work with necessary cutting of sheet, single side, double side coloured as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ adhesive tape/ screwing on the periphery of the sheet as per the required thickness etc. complete at all floors/ all levels/ all heights as per the drawing & directed by Engineer in charge. Cut edges of the compact sheet shall be provided with masking tape. Actual installed quantity shall be measured and paid.
Providing material and labour for fixing 1 mm thick Laminate sheet of approved make and shade on Non decorative flush door, panelling work, fixed partition, any ply surface etc with necessary nails, screws, adhesives as per drawings and as per approved sample. Laminate shall be either glossy, matt, Swede or any type of texture finish. The rate shall be for all heights, all floors, all places etc complete as directed by engineer in charge. Actual laid area shall be measured and paid without considering any westage.
Providing material and labour for fixing 6mm thick frame less mirror of approve make in any shape and sizes as per drawing. Mirror shall be fixed on 6mm thick cement bonded particle board (Bison panel) backing. Cement bonded particle board shall be fixed to wall with approved SS 304 fastener. All edges of glass shall be sharp grinded, cute corner and polished. Glass shall be fixed with silicon sealant/ 3M tape etc complete at all floors/ all levels/ all heights as directed by engineer in charge. Installed area of mirror shall be considered for payment without wastage. Rate shall be inclusive of cement board.
Providing material and labour for Extra charges for machined Perforation of required dia and pattern in flush door shutter/ compact sheet of any thickness for air circulation for all floor, all height all level as per drawing and as directed by Engineer in charge. Edges of perforation shall be finished and sharpen.
Providing material and labour forfixing single/ double action hydraulic floor spring with SS cover plate & adjustable concealed casted top pivot (two piece) and bottom strap of approved make for wooden/ aluminium doors of specified capacity with minimum one year guarantee. Rate shall be inclusive of cutting of floor neatly, grouting the floor spring & cleaning/ polishing the floor & maintaining in good working condition until defect liability period. In case of Aluminium shutter bottom arm of floor spring & top pivot shall be firmly fixed in the aluminium members using required size of teak wood by making rabbet in the wood. The Floor Spring shall conform to EN 1154. a) Hold open having weight up to 100 kg and shutter width upto 1200mm with std. spindle and cover plate. Closing force complying with EN 1154 2 - 4
Providing material and labour for fixing hydraulic rack and pinion door closer with standard arm (Silver finish) with screws to pivoted/ hinged door of approved make for specified door width with minimum one year guarantee. All adjustment screws face fixed. Rate shall be inclusive of fixing with using the template as per manufacturer’s specification & maintain in good working condition until defect liability period. The door closer shall conform to EN 1154 standard. a) with standard/ hold open arm with two independent closing valves and latching speed adjustable by arm without mounting back plate, Closing force complying with EN 1154 2 - 4 for up to 900 mm door shutter width
Providing material and labour for fixing SS-304 grade butt hinge of 100 x 75 x 3 mm - with ball bearing of approved make as per approved sample with necessary screws etc. complete for all floor all height all level as directed by Engineer in Charge.
Providing material and labour for fixing SS-304 grade butt hinge of 100 x 64 x 2.5 mm - without ball bearing of approved make as per approved sample with necessary screws etc. complete for all floor all height all level as directed by Engineer in Charge.
Providing material and labour for fixing set of dead lock of approved make with 55mm backseat, 20mm square for end with 72 mm centers including strike plate in satin stainless steel finish as per DIN 18251-1, grade 2 and prepared for euro profile cylinder (EPC) including strike plate and EPC length 60/70 mm standard Euro profile Pin Cylinder/ Half pin cylinder with both side key/ one side key one side knob operation with one pair of SS 304 Escutcheons (key hole plate) for wooden/ aluminium/ metal doors with necessary SS Phillips head screws etc complete for all floor, all level, all height as per approved sample and as directed by engineer in charge. The lock shall be with 3 keys.
Providing material and labour for fixing SS 304 satin finished set of narrow style dead lock of approved make with 25mm /35 mm set back necessary euro profile pin cylindrical lock 60/ 70 mm for Key and or knob operation and one pair of SS 304 Escutcheons (key hole plate) for aluminium door with necessary SS Phillips head screws etc complete for all floor, all level, all height as per approved sample and as directed by engineer in charge. The lock shall be with 3 keys.
Providing material and labour for fixing Mortise lock of approved make having 72mm centre to centre, 55mm Backset 20mm Square forend and 60/ 70mm standard Europrofile Pin Cylinder with both side key /one side key - one side knob operation and SS 304 grade hollow tubular pipe pair of Mortise handle of 22mm dia 150mm long with a pair of SS 304 Escutcheons (key hole plate) for wooden /aluminium/ metal doors with necessary ss phillips head screws etc complete for all floor, all height, all level as per approved sample as directed by engineern in charge. The lock shall be with 3 keys.
Providing material and labour for fixing Tubular dead bolt for toilet door of approved make with necessary screws etc complete for all floor, all height, all level as per approved sample as directed by engineern in charge. The lock shall be with 3 keys.
Providing material and labour for fixing Mortise shaft dead bolt of approved make with key (Alen Key lock), sleeve with 57mm backset and 25mm square forend in stainless steel satin finish etc complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing indicator bolt of approved make for toilet door with Thumb Turn inside & Emergency Release & Indicator Outside with necessary screws etc complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing SS 304 grade push-pull pair of handle of size 200 mm long x 19mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified.
Providing material and labour for fixing SS 304 grade push-pull pair of handle of size 300 mm long x 22 mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified.
Providing material and labour for fixing SS 304 grade push-pull pair of handle of size 450 mm long x 25 mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified.
Providing material and labour for fixing SS 304 grade push-pull pair of handle of size 600 mm long x 32 mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified.
Providing material and labour for fixing chromium plated brass/ SS 304 grade handles 150mm long D shape rod handle of approved make with both end bracket with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing 25mm diameter (1.5mm thick) SS 304/316 satin (brush) finish Disabled Grab Rails/ handle of 600mm long of approved make with necessary SS 304 grade screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing of SS 304 brush finish 450mm height Tower bolt (barrel type with minimum rod size shall be 10mm) of approved make in wooden doors/ aluminium doors/ metal doors with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing of SS 304 brush finish 250mm height Tower bolt (barrel type with minimum rod size shall be 10mm) of approved make in wooden doors/ aluminium doors/ metal doors with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing of SS 304 satin finish lever action Flush tower bolt with 19mm projecting bolt (extended rod of 600mm length) aluminum casted of approved make for double shutters aluminum door, with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing & fixing 200mm long (minimum rod size shall be 12mm and 50mm hanging handle) SS 304 brush finish Tadi (sliding bolt with out locking hole) of approved make with necessary screws, pins, bolts etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for Fixing SS 304 satin finish 100mm long Baby Latch including Bracket of 35 mm x 38mm, minimum Weight 198 grm with necessary SS Screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing SS 304 brush finish solid Door Stopper with magnet, fixed type, wall mounted (square/ round) of approved make with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing SS 304 brush finish solid Door bufer with pvc base, wall mounted (square/ round) of approved make with necessary screws etc. complete as approved by Engineer-in-charge in Charge.
Providing material and labour for fixing stainless steel (SS 304 grade) adjustable friction windows stays of size 355 X 19 mm of approved make with necessary stainless steel screws to the side hung windows etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing powder coated two point lock with mortise handle (without lock) of approved make with heavy gear mechanism of required capacity including all required accessories like handle, fork, connector, extensior, polyamide, locking point, corner transmission and striker etc as per approved manufacturer recomendatation for aluminium casement door and window (top hung or side hung) with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for ifxing of Hollow metal fire rated doors as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI against Test Schedule Ref No FR/0490 or ARAI for maximum rating of 2hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single & double leaf doors and Hardware should pass European certificate "CE" of conformity / UL with required fire ratings. Any deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer subject to architect’s approval and should be ISO Certified company. Providing material and labour for fixing Fire rated Door frame shall be double rebate profile of size 143 x 57 mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and SS 304 anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on the clear masonry opening. Frames shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test as per the directions of Engineer - in- charge. Rate shall be inclusive of anchore fastner and rubber silencer for all floor all level but excluding of SS ball bearing hinges).
Providing material and labour for fixing Fire rated Door shutter shall be 46mm thick fully flush double skin door with or without vision lite. Door shutter shall be manufactured from 1.2mm (18guage) minimum thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a beading and screws from inside. EPDM open cell sponge seal and bottom seal shall be provided at periphery and bottom of shutter as per manufacturer's specificatipon. Door shutter shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test as per the directions of Engineer - in- charge. Rate shall be inclusive of all type seal for all floor all level but excluding of vision panel and all type of hardware.
Providing material and labour for fixing fixed vision panel glass in fire rated door as per manufacturers recommendation with a G.I. beading, & special ceramic tape/ gasket of approved make etc complete for all floor all height as directed by engineer in charge. The glass should be 6mm clear borosilicate fire rated glass of 2 hour rating.(Actual installed glass size (with two decimal) to be measured for payments).
Mortise sash lock With Handle Providing and fixing narrow stile mortise lock with lever handle package complete set including lock, cylinder 1/2 Package with Pair of Design Lever Handle on Roses & escutcheons. Including narrow stile lock Sash lock with Backset as per door size 20mm Square forend. EPC 60/70mm length both side key operation or one side key and inside thumb turn with necessary screw etc. as approved by Engineer in charge.
Non Fire Rated Metal Door (Including Frame , Vision Panel and Shutter) Providing and fixing of non fire rated Hollow metal door at all levels from ISO 9001 -2000 certified Manufacturer. All hollow metal doors shall be fully metal with/ without vision panel or partly metal and partly glazed shautter. Pressed Galvanized steel Single/ Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be Double rebate profile of size 100 x 50 mm made out of 0.8mm thick galvanized steel sheet (20 gauge). Frames should be Mitered and field assembled with self tabs. Frames should be fixed with back plate bracket and anchor fasteners of approved size and make for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement slurry if recommended on the clear masonary opening. Door shutter should be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8mm (20 gauge) minimum thick galvanized steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads and reinforcement. The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be as per joinery details with a screw on glass beading on the inside. The vision glass should be 5mm clear toughened glass. Shutter shall be fixed to frame with SS 304 Ball Bearing Butt Hinges of size 100mm x 75mm x 3 mm (no of hinge as suggested by engineer in charge). All door shutter and frames shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate shall be include supply and installation of door i.e frame, anchor fastener, shutter with vision lite, hinge but exclude the cost of hardware (other than hinge) etc complete as directed by engineer in charge. Out to out area of door with frame shall be measured for payment. Incase of partly glazed shutter, area of glass shall ve deducted from measurement for payment and paid in relevant tender item. Shop drawing shall be prepared and submit by contractor and approved by Architect.
Providing and fixing SS 304 grade top bottom pair of Pivot of required capacity for door with all necessary ss phillips head screws etc complete as per drawing and sample approved by Architect/ EIC.
Frosted Film Providing and fixing in position PVC Frosting Glass film of approved make (of any pattern, shade and type) on glass partitions and doors for internal use. Film shall be pasted on glass without any appearing any air bubble. The rates shall be for all shapes and all heights with necessary scaffolding complete as per the Architectural drawings and manufacturer's specification & instructions as directed by the Engineer-in-charge. Film shall be with 10 years warranty.
Providing, Supplying and fixing ready made Access panel/ trap door (recess type) made from minimum 1 mm thick galvanised steel. Doors should be finished in Powder Coating with film thickness of 60 microns approx. in desired RAL Shades as approved by Architect. The manufacturer company must be ISO 9001-2015 certified. Same ceiling board shall be fixed in recess part (depth equal to thikness of board) of trap door. Door must be concealed type of hinges and appropriate provision for hanging from celling with locking system.
Providing, Supplying and fixing ready made Access panel/ trap door of size 600mm x 600mm made out of powder coated aluminium of approved make as per drawing including aluminium outer and inner frame, door, push latch, safety cable, removable hinge, intermediate and perimeter channel etc for all floor, all height etc complete as directed by engineer in charge. Contractor shall submit the technical data sheet of product regarding loading capacity to engineer in charge. Loose and fixed sample of access panel shall be approved by engineer in charge. Cost shall be inclusive of false ceiling board as per surrounding ceiling and its finishing.
Providing, Supplying and fixing ready made Access panel/ trap door of size 600mm x 1200mm made out of powder coated aluminium of approved make as per drawing including aluminium outer and inner frame, door, push latch, safety cable, removable hinge, intermediate and perimeter channel etc for all floor, all height etc complete as directed by engineer in charge. Contractor shall submit the technical data sheet of product regarding loading capacity to engineer in charge. Loose and fixed sample of access panel shall be approved by engineer in charge. Cost shall be inclusive of false ceiling board as per surrounding ceiling and its finishing.
Providing, Supplying and fixing ready made Access panel/ trap door of size 750mm x 750mm made out of powder coated aluminium of approved make as per drawing including aluminium outer and inner frame, door, push latch, safety cable, removable hinge, intermediate and perimeter channel etc for all floor, all height etc complete as directed by engineer in charge. Contractor shall submit the technical data sheet of product regarding loading capacity to engineer in charge. Loose and fixed sample of access panel shall be approved by engineer in charge. Cost shall be inclusive of false ceiling board as per surrounding ceiling and its finishing.
Providing and applying water based, low VOC, breathable and biodegradable, water, oil and stain repellent transparent coating with anti graffiti property on natural stone cladding/ Exposed RCC surface (suitable product according to sand stone/ marble/ granite) of approved make having acrylic fluoropolymer technology at all heights & leads and wherever instructed by Engineer-In-Charge. The treatment shall be in two coats wet-on-wet or as recommended by approved manufacturer including preparation of surfaces by cleaning, curing, protecting, independent double legged scaffolding etc complete. The rate includes the cost of all materials, its application by specialized applicators by spray coating with airless sprayer, cleaning the substrate of all laitance, construction dust, contaminants, double scaffolding, labour etc., all complete and at all levels, leads and heights as per particular specification & directions of Engineer-in-Charge. Guarantee Bond in the prescribed proforma shall be executed by the contractor for the satisfactory performance of the application for 10 years. The look and feel of the natural stone surface shall not be affected by coating.
Providing and fixing brass pivot of required size, top bottom pair of Pivot of required capacity for door with all necessary ss phillips head screws etc complete as per drawing and sample approved by Architect/ EIC.
Providing material and labour for fixing 120 min fire rated SS 304 Ball Bearing Butt Hinges 100mm x 75mm x 3 mm CE marked for fire rated metal door of approved make with necessary screws etc. complete as recommended by manufacturer for all floor all height and as directed by Engineer in Charge.
Providing material and labour for fixing Fire rated (120 minutes) Rack and pinion non-handed door closer of approved make EN size 2-4, with back check and standard arm with two independent closing valves and latching speed adjustable by arm. All adjustment screws face fixed with slide plate. The door closer shall be with Silver finish cover. The door closer shall conform to EN 1154 standards and CE marked with necessary fittings etc. complete for all floor, all height as recommended by manufacturer and as directed by Engineer in Charge.
Providing material and labour for fixing 1 point panic device in Contur design, carry bar for single door for fire and smoke check doors, with steel latch, security anti thrust latch for door widths upto 1300mm, consisting of 2102F, 2105 in silver finish of approved make. As per EN 1125, CE marked etc. complete for all floor, all height as recommended by manufacturer and as directed by Engineer in Charge.
Providing material and labour for fixing External trim with design lever handle of approved make suiting the panic bar for fire and smoke check doors for max. 60mm thick door prepared for half euro profile cylinder and in Silver finish with necessary fittings etc. complete for all floor all height as recommended by manufacturer and as directed by Engineer in Charge.
Providing material and labour for fixing 75mm thick wooden Asbestos Free Accoustic cum fire/smoke door of 120 minutes fire rating, conforming to BS: 476 part 22 IS: 3614 part -II, suitable to achieve apprrox. 32db, sound reducing properties suitable for fixing in wooden door frame of suitable section 140X90mm made out of Hardwood and the shutter comprising of 2 non -combustible boards sandwiching 41 mm thick fire resistant & accoustic insulation filler. The shutter is faced with 6mm thick commercial ply and 1mm thick Laminate on both faces and Hard wooden lipping all around the shutter. The frame shall be fitted with fire & smoke intumescent seal of size 10 x 4mm on all the three sides except bottom and shutter shall be fitted with fire & smoke intumescent seal of size 20 x 4mm on all the three sides except bottom. Autometic drop down seal shall be fixed at bottom of each shutter. . The shutter is fitted with the frame with the help of SS 304/ brass ball bearing hinges of size 125x89x3mm ( 04 nos. per leaf) including all type of accoustic seal. Rate shall be inclusive of wooden frame, door shutter, laminates, all type of seals, SS 304 grade/ brass heavy duty hinge, necessary SS 304 anchor fastner etc complete. Finishing i.e. laminate, polishing shall be paid in relevanrt tender item.
Sec.7.0 Plastering & Pointing works Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) upto Basement Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Ground Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for First Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Second Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Third Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Fourth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Fifth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) upto Basement Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Ground Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for First Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Second Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Third Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Fourth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Fifth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished upto Basement Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished for Ground Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished for First Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished for Second Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished for Third Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished for Fourth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished for Fifth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for fixing G.I. hexagonal chickenmesh of size 20mm x 20mm of 22 gauge at junction of concrete and brick work or between different materials after making "V" grove between two different material surface and filled with rich cement mortar and @ 100mm on each side of surfaces including necessary "U" nails/ screws/ washers with cleats for fixing, overlaps, curing, scaffolding etc complete for all floors/ all levels/ all heights/ all shapes as per direction of Engineer-in-charge.
Sec.8.0 Waterproofing works Providing material and labour for laying average 18mm thick double coat (water proof) smooth/ wired finish cement plaster on sides of masonry work/ block wall/ RCC wall, 12 mm thk first coat in CM 1:3 (1 cement : 3 coarse sand) by spraying , second coat of 6 mm of CM 1:3 (1 cement : 3 fine sand) and mixing Integral waterproofing liquid admixture for mortar in recommended proportions in both coats, finishing the surface wired finish/ smooth finish with a floating coat of neat cement slurry at 2.75 Kg/ sqm to receive the tiles for all floors, all shapes and all height including hacking to RCC surface, scaffolding, curing etc. complete for all floor, all height as directed by engineer-in-charge. Cement slurry admixed with Integral waterproofing liquid admixture for mortar in recommended proportions is to be applied before each coat and final finishing coat.
Providing material and labour for laying average 50 mm thick IPS, water proof cement concrete flooring in 1:2:4 (1 Cement : 2 Sand : 4 Graded Aggregate 10mm Nominal size) to RCC under ground tanks at all heights in line, level and gradient including mixing water proofing compound in recommended proportions suggested by manufacturer as approved by Engineer-in-charge and leaving the surface rough wired finish to receive any type of flooring / smooth finish etc complete for all floor all height as directed by engineer in charge.
Providing material and labour for laying integral cement based water proofing treatment (India type brick bat) including preparation of surface as required for treatment of roofs, balconies, terraces etc with average thickness of 120 mm and minimum thickness at khurra as 65 mm and consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with wired finish to receive china mosaic flooring. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge for all height all level.
Toilet waterproofing Providing material and labour for carrying out waterproofing treatment to sound concrete surface of toilets, sunken slabs, corridors, wet areas etc. after proper surface preparation to remove loose dust, dirt etc., repairing of cracks (if any) using polymer modified mortar, carry out cementitious injection grouting at leakage points modified with Plasticized Expandive Grout Admixture @ 225 gms per bag of cement, carry out 50 mm thick cement mortar (1:3) vatta/ corner modified with Styrene Butadine Polymer bonding agentat dosage of 2.5 Ltr per 50kg cement, Pre-dampening concrete surface, mixing and application of two coats of Elastomeric Polymer modified cementitious waterproofing coating by incorporating alkali resistance 45 gsm glass fibremesh between 1st and 2nd coat using suitable brush or roller as per coverage etc. complete for all floor al height all level as per manufacturer’s specification and as directed by engineer in charge. Cured Polymer modified cementitious waterproofing coating shall comply with ASTM D4060, ASTM D4541, ASTM D638,ASTM C836 and possess below properties: Mixed density: 1.68 g/cc, Adhesion to concrete-> 1 N/mm2, Non-toxic, Static crack accommodation-1 mm Water proofing system shall be executed by only approved applicator of approved brand and under strictly supervision of technical fellow of manufacturer. The rate includes giving 10 year guarantee for waterproofing on a Rs.100/- stamp paper in approved proforma.
Hole Packing treatment on service line Providing material and labour for applying total packing treatment on any type of pipes comes into water proofing area for all floor, all height as directed by engineer in charge as follows : Preparing the inside surface of core and Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Applying a coat of styrene- butadiene based polymer coating using Styrene Butadine Polymer bonding agentto enhance adhesion between the packing material and other surfaces. Packing the gap using non shrink cement polymer based grout using Non-shrink cementitious grout upto the surface of the bore whilst the bonding agent is in tacky state before application of water proofing treatment. Treatment shall be executed by same agency with same manufacturer's product. Warranty includes in water proofing item.
Providing material and labour for applying hydrophilic crystalline based waterproofing for concrete walls, raft (basement and under ground water tank) with system In two coat application. The application to be done from + ve (positive) side on a wet open pore green concrete surface at coverage of 0.8 to 1 Kg/Smt as per manufacturer specification. It should be hydrophilic in nature, should be able to grow crystals year after year to seal microcracks.The product should confirm to DIN 1048 part 5 and should provide in depth crystallization. The product technology should be CPWD and EIL approved. Application should be done on wet surface after 3-6 hours of casting of concrete. The material and application warranty to be given by manufacturer’s authorized distributor/ applicator on prescribed format. Rate shall be inclusive of construction joint treatment, crack repair, patch repair, grouting, including cost of scafolding for all height all level as directed by engineer in charge.
Providing material and labour for applying of Swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure, such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge for all floor, all height all level. The product performance shall carry guaranteed for 10 years against any leakage.
Sec.9.0 Flooring works Providing material and labour for laying Ceramic tiles 6mm thick in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush pointing in white cement, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge.
Providing material and labour for laying Ceramic tiles 6mm thick in skrting, risers of steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge.
Providing material and labour for laying 25mm thick (average) polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift in any shape and pattern etc complete as directed by Engineer In charge.
Providing material and labour for laying polished kota stone slab 25mm thick in risers of steps, skirting, Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift etc complete as directed by Engineer In charge.
Providing material and labour for laying 25 mm thick mirror polished machine cut kota stone slab of size upto 2.0mt length with uniform thickness for flooring, skirting, dedo, tread, riser, window jambs, coping over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with gray cement slurry including champhering in same gauge of exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. All Expose edges of stone shall be chmphered with same thickness and polished at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing material and labour for fixing 30 mm thick both side polished Kota stone upto 1.5mt long for shelves, counter, patitions in walls in CM 1:2, including making zaris 25 mm deep, fixing and making good all around, curing and semi mirror polishing to kota stone, at all floors any heights, any lead and lift etc complete as per drawing and directed by engineer in charge. The rate includes rounding, champhering and fine polishing of edges, maintaining upto handling ovre the project etc. complete as directed by engineer in charge.
Providing material and labour for laying 25mm thick (average) rough chiseled dressed kota stone flooring over 20mm average thick base of cement mortar 1:5 (1-Cement : 5-coarse sand) including pointing with cement mortar 1:2 (1-cement : 2-stone dust/sand), curing etc complet for at all floors any heights, any lead and lift etc complete as directed by Engineer Incharge.
Providing material and labour for laying cement concrete pavement (of any thickness) with 1:2:4 (1-cement : 2-coarse sand : 4-stone aggregate 20mm nominal size) including curing, finishing with floating coat of neat cement complete at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing material and labour for laying 24" x 24" vitrified 8 to 10 mm thick tile (Antiskid and matt finish) flooring, otta, Skirting over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing, curing & cleaning the surface for all floors all heights, all lead and lift etc complete as directed by Engineer Incharge. Rate shall be inclusive of base palster.
Providing material and labour for laying 8 to 10mm thick, double charged Vitrified tiles (of any shade glossy or satin finsh) of size upto 24" x 24"of approved make, shade and finish as approved by Architect/ EIC (Glossy) for all floors/ any height/ any levels etc in skirting, dado, risers of steps, jambs as per drawings. Wall tile is to be fixed over 10 to 12 mm thick wired finish plaster in cement mortar 1:3 (1 cement : 3 coarse sand) and average 6mm thick 1:1 cement sand mortar including pointing in white cement mixed with pigment of matching shade etc including curing, cleaning with mild oxalic acid, maintaining till handling over at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. Rate shall be inclusive of base palster.
Providing material and labour for laying approved quality mirror polished average 18mm thick Granite of approved shade in floor, otta, sill, skirting in any pattern etc sizes upto 600mm including average 20 mm thick cement mortar bedding in 1:6 laid and jointed with white cement and matching pigment including rubbing, re-polishing after fixing to remove any undulation between the joints (if required) with different grades of Emery, refilling of open joints, curing, daily cleaning and mopping, as directed for at least 15 days or up to the satisfaction of the EIC and as per approved sample and as directed by Engineer in charge at all floors/ all levels/ all heights and all shapes. (Only finished work will be measured.)
River wash finish Granite stone Flooring Providing material and labour for laying approved quality 18mm thick River finish Granite of approved shade in floor, otta, skirting, pavement, plaza or similar in any pattern including average 20 mm thick cement mortar bedding in 1:6 laid and jointed with white cement and matching pigment including rubbing, curing, finishing, cleaning etc complete as directed by EIC. Sample shall be approved before execution. Laying patern shall be as per drawing and instruction of EIC for all floors/ all levels/ all heights and all shapes. (Only finished work will be measured.)
Providing material and labour for fixing 18mm thick mirror polish Granite of uniform size and colour for treads and risers of stair, on coping etc size 1000mm to 2000 mm long, of approved shade, including necessary machine - cut edges (uniform thickness) rounded edges, as per design in required sizes and shapes over 20 mm (average) thick bedding of cement mortar 1:6 (1 cement: 6 coarse sand) laid and jointed with white cement and matching pigment including rubbing, re-polishing after fixing to remove any undulation between the joints (if required) with different grades of Emery, refilling of open joints, curing, daily cleaning and mopping, as directed for at least 15 days or up to the satisfaction of the EIC etc complete for all floors any heights, any lead and lift as per approved sample by Architect, drawings and instruction of EIC. The rate shall be inclusive of making rebates of 10x10mm for forming the grooves between treads and risers with polishing inside the groove. The rate includes machine cut edges of uniform thickness, rounding of edges, champhering and mirror polishing of edges and maintaing upto hand over the project.
Providing material and labour for fixing machine cut, mirror polished 18mm thick best quality Granite stone slab as per approved sample for dado, cladding, skirting, risers of steps etc., in required size and pattern as per drawing, laid on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, or fixed with stone fixing adhesive as per manufacturer's specifications including mirror polishing, champhering, edge polishing, rubbing, curing, finishing, necessary scaffolding, maintaining upto handling over the project etc complete for all floors any heights, any lead and lift etc complete as directed by Engineer Incharge. Backing coat plaster for dado shall be paid in relevant tender item. Shade of skirting must be match with flooring stone. Rate shall be inclusive of SS 304 grade pin and fastner for fixing the stone with mortar if required and/ suggested by engineer in charge.
Providing material and labour for fixing both side mirror polished 18mm thick best quality Granite stone slab as per sample approved by Engineer in charge with edges rounded and mirror polished, of required size fixed as urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement mortar 1:2 (1 cement : 2 coarse sand) as per drawing and as per direction of Engineer-in-charge. All expose edges shall be champhered and mirror polished. Rate shall be inclusive of chasing, cutting, edge champhering, edge polishing, curing, finishing, maintaining upto handling ovre the project etc complete for all floors all level etc complete as directed by Engineer Incharge.
Providing material and labour for fixing mirror polished 18mm thick best quality Granite stone slab as per sample approved by Engineer in charge with edges rounded and mirror polished, of required size fixed as platfrom/ vanity counter by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement mortar 1:2 (1 cement : 2 coarse sand) as per drawing and as per direction of Engineer-in-charge. 75mm high facia shall be fixed at the edge of platform with epoxy or stone fixing adhesive as per drawing. All expose edges shall be champhered and mirror polished. Rate shall be inclusive of chasing, cutting, edge champhering, edge polishing, making holes, curing, finishing, maintaining upto handling ovre the project etc complete for all floors all level etc complete as directed by Engineer Incharge. Installed area of platform and facia shall be measured for payment.
Providing material and labour for laying sandwich platform comprising of a) Sandwich of 18 mm thick single side polish Granite of approved size, shade and sample on top and 30 mm thick polished kota in bottom with 25mm thick cement mortar (1:4) in between b) At centre vertical sandwich supports of 30 mm thick two kota stone on sides and 20mm CM (1:4) in between and at both end walls vertical supports of 18 mm thick double side granite. c) 75 mm raised platform at bottom with kota on top and 50mm CM (1:4) at bottom, kota stone skirting as per design and approved sample. The rate includes rounding, champhering and mirror polishing of edges, facias of granite, MS support including necessary bonding adhesive (if required). Rate shall be also inclusive of curing, making holes & cutouts for sink, wash basin, Piller tap/ Bib tap at all floors all height etc complete as directed by Engineer Incharge. (Only plan area shall be measured & paid for). Rate shall be included all kota & granite mentioned in above.
Providing material and labour for laying machine cut single polished 18mm thick Jesalmer yellow stone in flooring, band etc as per design and drawing over 20 mm thick cement mortar 1:3 and pointing in joints in white cement with matching pigment, curing etc. complete. The rate should also include for polishing with different grades of emery, daily moping with water, buffing, finishing at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing material and labour for roughened strip 2.5 cm wide to form antiskid surface on treads of stairs in any type of stone including forming straight deep curved gishi (groove), 6 mm wide & 4 mm deep on two sides of the roughened area, chiseling, polishing the edges, sides and bottom of gishi etc. complete as per sample approved for all floor, all height. Only one time length of tread of stair shall be measured for payment.
Providing material and labour for laying broken china mosaic flooring for terrace using 12 mm to 20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or slope and to be tempered to bring mortar creme out upto surface using white cement including rounding off junctions and extending them upto 15 cm along the wall, curing, clearing with water and oxalic acid etc for all level, all height as directed by engineer in charge.
Providing material and labour for laying Porcelain Mosaic tiles of make by piccolo, Italia or Equivilant in different sizes (25mm x 25mm/ 50mm x 50mm/ 100mm x 100mm) having 8 mm thickness with water absorption less than 0.08% and conforming to IS: 15622, in any colours and shade, in Water body, skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints for al depth al level as directed by engineer in charge. The Glass mosaic tile shall be fixed as per approved pattern and design. Sample to be approved by Architect.
Providing material and labour for laying external grade full body homogeneous 10 to 12 nn thick hard vitrified tiles upto 600 mm x 600 mm size of approved make, shade and finish (Matt, Satin, Non skid, Rustic) as per design in floor with residue and of size upto 610mm x 610mm, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness over average 20 mm cement mortar and laid to proper slope, including grouting of joints, curing and cleaning with mild oxalic acid etc. complete as directed by Architects and Engineer in charge. Rate shall be inclusive of making 3mm groove with PVC spacer and filling the grove with epoxy grout of approved and shade, protection of flooring until the handling of the project for all floor, all level as directed by Engineer in charge. Only plan area should be measured and paid.
Providing material and labour for laying Cement Mortar for additional floor bedding in Cement Mortar 1:6 (1-Cement: 6 - coarse sand) including curing etc for all floor, all level all height. Additional bedding thickness shall be as per drawing and as directed by engineer in charge.
25mm Kotastone Flooring - Lecture hall Floor with curved Flooring Providing material and labour for laying 25mm thick (average) polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift in any shape and pattern etc complete as directed by Engineer In charge.
Providing material and labour for laying 25 mm thick mirror polished machine cut kota stone slab of size upto 2.5mt length with uniform thickness for flooring, skirting, dedo, tread, riser, window jambs, coping over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with gray cement slurry including champhering in same gauge of exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. All Expose edges of stone shall be chmphered with same thickness and polished at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing material and labour for laying 40 mm thick mirror polished machine cut kota stone slab of size upto 2.1mt length with uniform thickness for flooring, skirting, dedo, tread, riser, window jambs, coping over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with gray cement slurry including champhering in same gauge of exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. All Expose edges of stone shall be chmphered with same thickness and polished at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Italian Marble Flooring Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in Charge.
Extra for ornamental/ Intricate inlay flooring Extra for Providing & laying ornamental/ Intricate Inlay designer flooring on base of marble/granite flooring with specified inlay pattern with different required shade of marble, sand stone, lime stone, Granite or other specified material per design. Inlay pattern shall be done with CNC cutting machine/ laser cutting/ manual or by any means as per concept image or drawing. Contactor shall prepare shop drawing base on concept drawing or image and get it approved. Contractor shall prepared mock-up as per approved shop drawing and suggested by Architect. Inlay : Providing and laying inlay pattern with specified stone over base stone flooring stone as per approved shop drawing and approved sample. Base stone and inlay marble shall be cut with CNC cutting machine/ hand cutting and making pattern as per approved shop drawing. Inlay shall be fixed with suitable adhesive on existing base flooring. The thickness of inlay material shall be of required thickness of base stone. While applying the adhesive for marble or other stone inlay, color of marble or other stone shall not get varied. After completion of laying of base and inlay, contractor shall finish entire floor (as specified) as per satisfaction of Architect and Engineer in charge. Rate shall be inclusive of inlay material, labor, adhesive, grout, wastage, curing, cleaning with water jet, finishing, etc complete for all floor level and as directed by engineer in charge. Base stone flooring shall be paid in relevant tender item. Flooring area with inlay work shall be measured for payment.
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick flat
20mm premix carpet surfacing with 1.8 cum and 0.90 cum of stone chippings of 13.2 mm size and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately) with paving Asphalt grade VG - 30 with no solvent.
Providing and fixing Brass inlay strip in stone flooring and wall paneling work or similar elements including welding, grinding, buffing, polishing and making curvature (wherever required) and fixing the elements with necessary accessories & Brass/ SS316 dash fasteners, brass bolts etc., of required size with suitable arrangement as per approval of Engineer in charge. Brass shall be heavy and good quality clear satin finish. (for payment purpose only weight of brass members shall be considered of actual installed quantity excluding fixing accessories such as nuts, bolts fasteners etc.)
Grouting the joints of flooring tiles for average size up to 600mm x 600mm having joints of 3 to 5 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade from approved make (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Sample shall be approved before procurement of material.
Providing and laying Dry Stone Pitching including supply of stones and preparing surface, laying the stone etc. complete as per drawing and as directed by EIC.
Dry stone cladding with Red Agra stone Providing material and labour for fixing stone cladding on wall for all heights with natural finish AGRA RED stone of 40 mm thick, machine cut having size upto1200mm with grooves (10mm x 10mm) in both direction, sealing the joints with approved weather sealant of matching shade as per detail design and drawing. The stone shall be fixed with stainless steel clamps (304 grade) of required size and approved make, inserted in the wall, curing etc. complete. The rate shall also include grouting the clamps in brick/ RCC wall with non shrink cement mortar and SS 304 anchor fasteners for RCC surfaces, etc. complete for all level all height as directed by engineer in charge. Contractor shall prepare shop drawing based on concept drawing and get approved by engineer in charge/ Architect before execution. Contractor shall approved loose stone and mockup as per approved sample and shop drawing. The work shall be carried out as per the cladding sample approved by Architect and engineer in charge. Necessary MS structure shall be paid in relevant tender item.
Sec.10.0 Structural steel works Providing material and labour for, fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using MS Rolled Steel Sections, Hollow sections, Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheet, Flats, Bars , Angles, MS Sheet, Girder, Beam, cattle trap, deep threaded MS bolts, threaded J bolts, insert plate, support plate etc as per drawing. all confirming to latest relevant IS codes for the work of steel structures like staircases, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap, rungs, false ceiling frame work, Roof canopy, fencing posts, M.S. Screen & fencing jali frame work etc. including straightening, cutting, bending, bolting and welding the members all as per approved shop drawings and as per detailed specifications (for materials & workmanship) including necessary scaffolding/ staging etc. complete and comprising of Profile Cutting, Smooth grinding/ machining of edges/ faces/ all welding joints; Necessary welding ; Machine drilling of holes for joining/ anchoring; dry sanding, degreasing (wet cleaning) & preparation of rustfree surface manually or mechanically, metal putty to make the surface even and smooth, 1 coat zinc chromate yellow oxide primer and 2 coat of enamel paint of approved make shade of paint over all the surfaces of the steel sections. The Contractor shall prepare shop drawing as per GFC drawing and as per actual site condition and get approved before execution by engineer in charge. (Standard measurements will be paid for as actual cut length used at site)
Extra over and above on item no - 10.1 for epoxy primer and 2 coats of PU paint of approved make and shade on MS work as per drawing for all floor, all height, all level and as suggested by Engineer in charge.
Providing material and labour for fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked together through their entire length and jointed together at the ends by end locks mounted on specially designed pipe shaft with bracket plates, guide channels and arragements for inside and outside locking with push-pull operation including the cost of hood cover and spring, 1 coat of Yello zinc chromate primer and 2 coat synthetic enemel Paint of approved make and shade over all the surfaces etc. complete for all floor all height as directed by Engineer in charge. (A) Shutters having width upto 3.5 M.
Providing material and labour for fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked together through their entire length and jointed together at the ends by end locks mounted on specially designed pipe shaft with bracket plates, guide channels and arragements for inside and outside locking with push-pull operation including the cost of hood cover and spring, 1 coat of Yello zinc chromate primer and 2 coat synthetic enemel Paint of approved make and shade over all the surfaces etc. complete for all floor all height as directed by Engineer in charge. (B) Shutters having width 3.5 M. and above
Providing material and labour for, Fabricating and fixing SS hand rail / railing, gratings, corner guard of 304 grade made out of round, square or rectangle hollow sections, angle, plate, flat, rod/bar in satin/ brush finish including supporting fittings made out of SS 304 grade solid rods, flanges, compatible SS anchor fastener (mechanical or chemical) of Hilti or equivalent as per manufacturer's specifications, SS connecting bolts of required size with washers, SS base plate, lath work, argon arc welding, buffing, bending and bends as per the detail drawing with best (high) quality finish & as per the a sample approved by Architect and as directed by engineer-in-charge. Rate shall be inclusive of all material, labour wastage and for all floors/ all levels/ all heights. Railing shall be measured in KG & paid accordingly. Actual installed length of member shall be measured and no extra shall be paid for consumable fasteners.
SS water trough Providing material and labour for, Fabricating and fixing SS 304 grade water trough of size 300mm x 450mm with 300mm high SS sheet cladding (dedo) made out of 1.2mm thick sheet and required size of angle, flat etc in satin/ brush finish including supporting fittings made out of SS 304 grade solid rods, flats, anges, compatible SS anchor fastener (mechanical or chemical) as per manufacturer's specifications, SS supporting arrangement, latth work, argon arc welding bending and bends as per the detail drawing with best (high) quality finish & as per the a sample approved by Architect and as directed by engineer-in-charge. Rate shall be inclusive of all material, labour and wastage for all floor, all height, all level. Water trough shall be measured in Rmt. Installed length shall be measered. Contractor shall prepare shop drawing based on concept drawing ant get approved before execution.
Sec.11.0 Painting works White washing with lime on wall and ceiling surface (two coats) to give an even shade including thoroughly booming the surface to remove all dirt, dust; mortar drops and other foreign matter etc complete for all floors, all heights, all level as directed by Engineer Incharge.
Providing material and labour for applying (Synthetic) Plastic emulsion paint (minimum 2 coats) having VOC (Volatile Organic Compound) content less than 50 gm/ltr on newly dry interior plastered surface including ceiling, roof etc.at all heights/ all levels/ all surfaces to give an even shade including applying required coats (min two coats) of white cement based putty after thoughly brushing the surfaces free from mortar dropping and other foreign matter. Preparing the surface even and sand papered smooth, after applying every coat of putty complete. Priming coat of alkali resistant cement primer (water or solvent based) is to be applied over prepared smooth surface (undulation free) etc. complete as directed by engineer-in-charge. Sample to be approved before starting of the work by Architect/ EIC. The rate shall include the cost of filler for filling the cracks on surface, thoroughly brushing the surfaces with sand paper to make it free from mortar dropping and other foreign matter, scaffolding etc. as directed by engineer in charge.
Providing material and labour for applying Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc complete for all floors, all heights, all level as directed by Engineer Incharge.
Providing material and labour for applying external finish of average 2 to 2.5mm thick acrylic polymer based texture and pattern with standard tool and applicator as specified by manufacturer on exterior surfaces at all heights including scaffolding to give even shades including thoroughly brushing the surfaces free from mortar droping and other foreign matter and sand paper smoothed as per the manufacture specifications etc. complete for all floor, all height, all level and up to the satisfaction of Engineer in-charge/ Architect. The rate includes making of grooves, pattas and finishing as directed by Engineer in charge. Paint shall be measured and paid in seperate tender item. (Item should be executed by approved applicator only.)
Sec.12.0 Roofing works Providing material and labour for fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC for the best thermal Insulation. The Light weight calcium Silicate tile shall be of approved texture of size 595 X 595 x 15 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross ‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm centre to centre to form agrid of 1200X600mm and secondary cross ’T’ to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting on periphery walls/ partitions on a perimeter wall with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges light weight calcium silicate ceiling tiles in the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, as per specifications, drawings and as directed by engineer-in-charge. Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. Value of 0.50 (Minimum) and 0.75 NRC for Globe, light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity. 0.043° w/m KC.for the best thermal Insulation at all floors, any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing & Fixing M/F Suspended 12.5mm Plain Gypsum Board which includes GI Perimeter Channel is fixed along the perimeter of existing wall/ partition with the help of screws at 600mm centres. GI Ceiling Angle is suspended at up to suitable height as per sight conditions by fixing it to the GI soffit clit with Soffit Cleat and Rawl Plug creating 1220mm x 1220mm grid. GI Intermediate channel is fixed to the GI Ceiling Angle with 2 Nos of 4.2x13 GI metal to metal screw. The GI Ceiling Section is then fixed to the GI Intermediate Channel with the help of Connecting Clip and in direction perpendicular to the Intermediate channel at 457mm c/c. Single layer of 12.5mm tapered edge Plain Gypsum Board (Confirming to IS 2095-Part-I, 2011) is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing Compound & Joint Paper tape. The contractor should prepare shop drawings based on the concept drawing and get it approved by the Engineer-in-charge. After approval of drawings, the contractor shall prepare the sample based on the drawing and get it approved by the Engineer-in-Charge before execution. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights/ air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/ cutouts, making grooves between wall & board or as per drawing for all floor, all level, all height etc as directed by Engineer in charge. Area of cutouts shall not be deducted and no extra payment shall be considered for additional sections provided. Only plan area shall be considered for payment.
Metal False Ceiling: Providing material and labour for, fixing and laying of plain finish GI metal ceiling system consisting of 600 mm x 600mm Clip-in with double pip self-leveling feature and special tabs to allow removal of tile to enable plenum access with plain visual consisting of 600mm x 600 mm clip in tiles of galvanized steel in 0.5 mm thickness with bevel edge in Global white color precoated with primer coat at the rear side with Light Reflectance > 60% and load carrying capacity of 14 KG/ SQM. The T-sections have a galvanizing of 90 grams/sqm and passed through 500 hrs of salt test. Tiles would have fire performance of Class A2-s1.d0 as per EN13501. Installation: To comprise 3000mm long ‘C’ channels spaced at 1200mm centers securely fixed to the structural soffit by support clamp & approved hangers. The last hanger at the end of each C channel should not be greater than 600mm from the adjacent wall. Use a C-channel connector for splicing two pieces of C-channels. 4000mm Main carriers (spring tee bars) shall be spaced at 600mm centers in a direction perpendicular to the C-channels and shall be secured at every intersection with C channel using a hanger. Use connector to splice two pieces of main carriers. Tiles should be clipped in between two carriers (spring tee bars) from below. Perimeter trims to be of wall angles of white color secured to walls at 450mm maximum centers. Cut tiles to be secured to the wall angles using a spring clamp. Tile, grid system and suspention system shall be of same make and as per approved sample. The Tile & Grid system used together should carry a 10 year warrantee. Installation will be done by approved installer only. The shop drawing, specification and sample mock of miniumum 5 Sqmt with framework shall be approved by Architect/ EIC. Rate shall also include cost of making of all cutouts for light fixtures, gadgets, gizmo, pelmets, grooves, beads and also provide support/ template where ever required. The rate shall be in Sqmt for all floors/ all heights/ all levels including scaffolding etc. as directed by Engioneer in charge.
Perforated Gypsum tile acoustic false ceiling : Supplying material labour for fixing of Suspended ceiling system with 12.5mm thick glass fibre perforated gypsum plaster board/ tile of any size having any type of edges and any shape, any size, any pattern perforation and GI suspended framing system. This includes ribbed frame Perimeter Channel fixed to brick wall/partition with the help of nylon sleeves and screws at 600mm centres along the perimeter of ceiling. Then suspending ribbed section used as intermediate channel from the soffit at 1220mm centres with Ceiling Angle fixed to RCC Slab with Soffit Cleat and steel expansion Fasteners @ 600mm Centres respectively. Ultra frame ribbed Ceiling Section are then fixed to Intermediate channel with the help of four point connecting clip (0.8mm thick) and in perpendicular direction to the intermediate channel at 600mm centres. 12.5mm thick glass fibre perforated gypsum plasterboards/ tile of any size having any shape, any size, any pattern perforation with acoustical tissue backing is screw fixed with 25mm long Drywall screws at 230 mm centres. The screw fixing of gypsum plasterboards to the metal framing at the periphery, openings and cut edges should be at 150mm centres. Finally square or tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound, Joint Paper tape and two coats of Drywall Top Coat as per the drawing & approved sample. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights/ air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/ cutouts, scafolding, making grooves between wall & board or as per drawing etc complete for all level, all height, all floor amd as directed by Engineer in charge. Only plan area shall be considered for payment.
Providing material and labour for Fixing of Mineral Fibre Suspended Ceiling System with Bioguard (Bevelled Tegular with grove) edge tile with 15mm Exposed grid. The tiles should have Humidity Resistance (RH) of 95%, Light Reflectance 90%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 Part 6 & 7), in module size of 600x600 x minimum 15mm with Anti Microbial coating on the face of the tile.The tile shall be laid on Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/ black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/M2 & minimum pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with suspension system of same make. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres. SUSPENSION SYSTEM accessories shall be of same make and consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.5 mm of 1.8 m length, thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.8mm thick, galvanised spring steel for 2.68 mm with a minimum pull strength of 110 kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner.Contractor shall provide 0 year warranty against Tile & Grid system used together. Installation shall be done by approved applicatior of manufacturer all floors/ all heights/ all levels including scaffolding etc as directed by Engineer in charge.
Providing material and labour for fixing fabricated metal single shutter/ double shutter trap door made from 0.8 mm MS sheet, Inner Frame - 1.5 mm, Outer Frame - 2mm MS sheet and finished with powder coating of approved shade/ enamel/ acrylic paint (primer + 3 coats of paint) of approved make and shade. Door shall be installed on existing false ceiling framing with extra MS suspender with necessary hardware like allen key lock, hinges/ pivot, safety chain etc complete as directed by engineer in charge. Rate shall be inclusive for providing, loading/ unloading, transporting and installation at all floor all height but excluding the cost of extra suspender for installing the trap door. Area of trap door with frame shall be measured for payment.
Fiber cement board : Providing material and labour for fixing exterior grade cement fibre board/ plank cement pattas of 8 mm thickness at exposed concrete ceiling/ wall/ beam bottom with brass/ SS head screws as per drawings, specification and sample approved at all floors, all levels and all shapes etc complete as directed by engineer in charge. Rate shall be inclusive of all material, labour, scafolding, tools, tackes etc complete.
Mineral wool insulation Providing material and labour for installing 50mm thick 48kg/cum density mineral wool (pre-wrapped) in the wall panelling and over acoustic false ceiling as per required application, for all floor, all height, all level as per drawing and as directed by engineer in charge.
Plywood +laminates Acoustic False ceiling Providing material and labour for fixing 12 mm thick water resistant ply confirming IS 303 BWR of approved make for false ceiling, which includes GI framing like GypSerra of Saint Gobain or equivalent. 1.0mm thick laminates of approved make and shade shall be paste on external side of 12mm thick ply with adhesive of approved make. Exposed edges of ply shall be covered with 12mm thick 1st class teak wood bedding in total depth. Bedding patti shall be finished with Lacquer polish of approved make and shade. Contractor shall cut perforations/ round holes of various sizes in uniform/ rendom pattern on ply and laminates panel as per the drawing and approved by EIC/ Architect. The holes shall be CNC cut in computer. Framing includes Perimeter Channel is fixed along the perimeter of existing wall/ partition with the help of screws at 600mm centres. Ceiling Angle is suspended at up to suitable height as per sight conditions by fixing it to the soffit clit with Soffit Cleat and Rawl Plug creating 1220mm x 1220mm grid. Intermediate channel is fixed to the Ceiling Angle with 2 Nos of 4.2x13 metal to metal screw. The Ceiling Section is then fixed to the Intermediate Channel with the help of Connecting Clip and in direction perpendicular to the Intermediate channel at 457mm c/c. Suggested/ Mentioned board/ ply is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. All members of ceiling system i.e perimeter channel, angle, soffiet cleat, intermediate channel, connecting clip etc is GI (IS513) having YS-300Mpa, Finish-Galvanised 150GSM (IS 277). Knurled steel section has effective thickness of 2T (2 x depth). Only plan area shall be measured and paid without considering any wastage. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights /air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/cut-outs, making grooves between wall & board etc complete for all floor, all level, all height. Area of cut-outs shall not be deducted and no extra payment shall be considered for additional sections provided. Contractor shall prepare shop drawing based on concept drawing and get approved by engineer in charge. Sample of all loose material shall be approved. Contractor shall prepare mock-up (minimum 2.0 Sqm) with complete finish and get approved by engineer in charge. Necessary MS structure for frame and hanging system should be paid in relevant items.
Plywood + laminates Acoustic wall panelling with GI framing : Providing material and labour for fixing 12 mm thick water resistant ply confirming IS 303 BWR of approved make for wall panelling, which includes GI framing like GI CLOSED STUD partition of approved make. 1.0mm thick laminates of approved make and shade shall be paste on external side of 12mm thick ply with adhesive of approved make. Exposed edges of ply shall be covered with 12mm thick teak wood bedding with total depth. Bedding patti shall be finished with lacqure polish of approved make and shade. Contractor shall cut perforations/ round holes of various sizes in uniform/ rendom pattern on ply and laminates panel as per the drawing and approved by EIC/ Architect. The holes shall be CNC cut in computer. Framing - 48x0.6mm CLOSED STUD should be placed at 600mm c/c in 50x0.5mm floor channel. Floor channel should be cut & bend and braced with Wall and closed stud at every 900mm c/c vertically. Floor channel is anchored to the floor & True ceiling using Rawl plug of Ø8x45mm (Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-7.5kN for M20 concrete grade) with suitable anchor fasteners at 600mm c/c in centerline manner. GI noggin channel of 48x0.5mm width has to be provided at the horizontal joints of the two boards. End of paneling shall be closed with same thickness of ply. Only elevation area shall be measured and paid without considering any wastage. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights /air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/cut-outs, making grooves between wall & board etc complete for all floor, all level, all height. Area of cut-outs shall not be deducted and no extra payment shall be considered for additional sections provided. Contractor shall prepare shop drawing based on concept drawing and get approved by engineer in charge. Sample of all loose material shall be approved. Contractor shall prepare mock-up (minimum 2.0 Sqm) with complete finish and get approved by engineer in charge. Necessary MS structure for frame and hanging system/ service elements shall be paid in relevant items.
Fabric wall panelling Providing material and labour for fixing 13.5 mm thick 'Silance' Acoustic and Sound Absorption Panel System, size 2700mm x 1200mm & weighing 6.45 kg per sheet, manufactured from 100% polyester fibers/ poly propylene / polyethylene terephthalate panel. Fibers Needle punched and thermally bonded in a non – woven matrix semi rigid specifically tooled and pressed for maximum sound absorption, with an 70% NRC (0.70 NRC). 'Silance' Acoustic and Sound Absorption Panel System is to be fixed on 24" (600mm) gap framework, of chemically treated wood (CCA treatment) of 40 mm x 25mm wooden patti, which shall be fixed into wall and which shall create true line and level with screws, fixed horizontally or vertically (as per architectural design). 'Silance' Acoustic and Sound Absorption Panel ('Silance' Acoustic and Sound Absorption Panel System panels can also be fitted as the same way as above using Gypserra GI frame or 'Silance' Acoustic and Sound Absorption Panel System can also be installed with suitable adhesive directly on the wall. Fabric shall be covered with Fabric of approved make and shade as per the drawing in pattern of specified size. Rate shall be inclusive of fabric, Lipping, labour, necessary hardwares, adhesives required, etc. Wooden Beading shall be applied on all the sides of the panels of required size. Lacquer Polish shall be applied on expose wooden lipping etc. The rates shall be inclusive of laquer polishing, all wastages, fabric, labor for applying fabric, taxes, transportation, loading, unloading, fixing in position for all heights, scafolding etc. Complete and as directed by Engineer-in-charge. Only elevation area of fabric shall be measured and paid in Sqm. Wastage shall not be considered. Contractor shall get the sample approved by Architect/ Engineer-in-charges.
Providing material and labour for fixing of 12 mm thick approved quality soft board of approved make with cotton cloth/fabric of approved make and shade on 12mm thick BWR 300 grade ply with 1st class teak wood beading all around including lacquer polish, as approved sample and as directed by Architect. Elevation area of the soft board including lipping shall be measured and paid. The rates shall be inclusive of all wastages, laquer polishing, fabric, labor for applying fabric, for all level, all heights etc. complete as directed by Engineer-in-charge. Wastage shall not be considered. Contractor shall get the sample and approved by Architect/ Engineer-in-charges.
Providing material and labour for fixing precoated galvalume iron profile sheets (size, shape, shade and pitch of corrugation as approved by Engineer-in-charge). Profile sheet of nominal1015 mm effective cover width and nominal 28.5 mm deep ribs with subtle square fluting in the five pan at nominal 203 mm centre-to-centre. The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (BMT), 0.50mm Total thickness, Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 45% Zinc) as per AS 1397 /IS 15961- Zincalume AZ150 (Min.150 gms/sq.mt total on both sides) with superior quality paint coat. The paint shall have a total coating thickness of nominal 35 μm, comprising of nominal 20 μm exterior coat on top surface and nominal 5 μm reverse coat on back surface over nominal 5 μm primer coat on both surfaces of approved colour shade. The sheet shall be fixed using Self Drilling, Self Tapping bolts of approved make of required size (and all necessary overlaps complying to the manufacturer's specifications including cutting to size and shape, erecting at all levels, all height, providing openings, all fixtures and fixing, accessories with EPDM sealing, silicon sealant at ridge and valleys including all material, labour, scaffolding, wastage, tools, tackles, equipment, transportation, shop drawing, and excluding the cost of purlins and rafters etc all complete as per drawings as directed by the engineer in charge . The rate shall include end laps, side laps, bolts etc. Sheets shall be supplied in custom lengths upto 12.0 m. All overlaps shall be sealed with silicone sealants for sloped roofings. Actual plan area of roof shall be measured for payment with out considering wastage and overlap.
Providing material and labour for fixing Thermoformed, UV protected/ UV coated one piece polycarbonate domes of size 2mm thick x 600 mm dia clear opening embossed/ transparent/ milky white with side step including fixing with brass screws/ ss 304 anchor fasteners of approved make, EPDM rubber and neutral grade weather silicone sealant of approved make and shade etc. complete for all floor, all level all height as per manufacture's specifications and as directed byEngineer-in-charge.
Sec.15.0 General Development and Road works Box cutting the road surface to proper slope and camber for making a base for road work including removing the excavated stuff and depositing on the road side slope as directed upto 1 Km lead and all lift.
Providing and laying rubble soling in plinth and sub-base of road, compacted thickness specified as following, using specified size of hard stones for average 150mm thick soling, filling, covering and leveling the surface with a layer of earth after filling the voids (upto 25%) with sand, smaller sized black trap stones 20-40mm, 40-63mm, 63-90, 90-150mm size of stone/metals or stone chips, including watering, ramming well and compacting or consolidating each layer by static roller/ vibratory roller of required capacity as directed by Engineer-in charge.
Construction of Granular Sub Base (GSB) by providing coarse graded material of any grade, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, including all material, labour, machinery with all leads and lifts etc. complete as per MORTH specification and as directed by Engineer in charge.
Providing material and labour for, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tripper to site, laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge.
Providing material and labour for applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 7.5 kg/10sqm using mechanical means including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge.
Providing material and labour for laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour/ DMP 60-90 TPH capacity using crushed aggregates of any grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction etc complete including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge.
Providing material and labour for applying Tack Coat with Cationic Bitumen Emulsion RS1 complying with IS:8887. The tack coat shall be applied by a self-propelled or towed bitumen pressure sprayer, equipped for spraying the material uniformly at the rate of 2.5Kg/Sqmt etc complete including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge. No dilution or heating at site of RS1 bitumen emulsion shall be permitted.
Providing material and labour for laying Bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ min 5.4 % of mix, transporting the hot mix to work site, laying with a self-propelled paving machine equipped with an electronic sensing device to the required grade, level and alignment, rolling with 8-10 tonne static weight or vibratory roller or with a pneumatic tyre roller of 12 to 15 tonne weight to achieve the desired compaction as per approved design mix etc complete including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge.
Providing material and labour for laying precast fair finish curbing of (factory made and vacume pressed) RCC M25 grade curbing 300mm height x 125mm thick including necessary excavation, cutting the road, laying PCC 1:4:8 (1 cement: 4 sand: 8 stone aggregate 20/37 mm. down size), shuttering, exposed rendering, curing, flush pointing CM 1:3 excluding reinforcement as per the drawing, as per approved sample and as directed by Engineer in charge.
Providing material and labour for laying precast fair finish curbing of (factory made and vacume pressed) RCC M25 grade curbing 450mm height x 125mm thick including necessary excavation, cutting the road, laying PCC 1:4:8 (1 cement: 4 sand: 8 stone aggregate 20/37 mm. down size), shuttering, exposed rendering, curing, flush pointing CM 1:3 excluding reinforcement as per the drawing, as per approved sample and as directed by Engineer in charge.
Providing material and labour for laying shot blasted Non-interlocking (factory made) high density 60 mm thick M35 grade any colour brick type paver blocks of required size of approved make and shade for footpath, parking areas, service lanes and other areas as mentioned in the drawing including average 50 to 80 mm thick bedding layer of coarse sand below paver block. Laid paver block shall be mechanically compacted and as directed by Engineer in charge. The work shall be executed in line and level by skilled mason of flooring work only for paver blocks. It should be laid in such a way that the No cutting of the paver block to be necessary and if required, cutting of paver block by machine cut only. The Finished surface of the paver block shall have coarse sand texture finish. Sample to be approved before starting of the work by Architect/ EIC.
Providing material and labour for laying shot blasted Non-interlocking (factory made) high density 80 mm thick M45 grade any colour brick type paver blocks of required size of approved make and shade for footpath, parking areas, service lanes and other areas as mentioned in the drawing including average 50 to 80 mm thick bedding layer of coarse sand below paver block. Laid paver block shall be mechanically compacted and as directed by Engineer in charge. The work shall be executed in line and level by skilled mason of flooring work only for paver blocks. It should be laid in such a way that the No cutting of the paver block to be necessary and if required, cutting of paver block by machine cut only. The Finished surface of the paver block shall have coarse sand texture finish. Sample to be approved before starting of the work by Architect/ EIC.
Providing material and labour for laying 60mm thick Solid Concrete Combination Cobbles of differant size, made by vibro pressed method of VYARA or equivalent as approved by Architect/ EIC, with +/-3mm tolerance and thickness of wearing layer not less than 5mm of any color and shade (UV Light resistant fast colours from Lanxess only to be used) having compressive strength of 30 Kg/cm2 for footpath, parking areas, service lanes and other areas as mentioned in the drawing. Combination cobbles shall be laid as per approved pattern and suggested by manufacturer and Architect. Including providing and laying average 50 mm thick average bedding layer of coarse sand below the block as per required grading and specification.Laid paver block shall be mechanically compacted and as directed by Engineer in charge. The work shall be executed in line and level by skilled mason of flooring work only for paver blocks. The Finished surface of the paver block shall have coarse sand texture finish. Sample to be approved before starting of the work by Architect/ EIC.
Providing material and labour for grouting joints of average 5mm wide and depth as per flooring thickness of required thickness for External pavement work. 5mm depth of groove at top gap shall be filled with epoxy grout of approved make and shade. Remaining depth (below 5mm depth) of gap shall be filled with cementitious grout of approved make and shade. Rate shall be inclusive of provision of gap by PVC spacer, filling the gap with both type of grouting material etc in any pattern as directed by Engineer in charge.
Providing material and labour for laying cement concrete broom finish/ smooth finish pavement for plinth protection/ CC Road 100 –150 mm. thick with M25 concrete including giving a floating coat of 1:1 cement mortar, with Nominal temperature steel, tie bar, dowel bar as per MORTH specifications of section -6 etc complete as specified by the Engineer-in-charge. The rate shall be exclusive of reinforcement steel, dowel bar etc. The same shall be paid in relevant tender items. Rate shall be inclusive of concrete (to be laid in alternate panels size shall be apprx 4.5mt X 5.0mt ) with fair finished steel channel formwork, saw cutting of construction & contraction joints in width 3 to 5 mm x 1/4 to 1/3 thickness of pavement, filling the 25mm x 20 mm (BXD) expansion joint approximately at every 30 mt with readymix bitumiNous filler as per sample approved & directed by engineer incharge etc complete. Screened Sand to be only used
Vaccum dewatering Extra for carrying out vaccum dewatering & Power floater treatment in roads, pavements, floors well compacted, mechanically vibrated with screed vibrator, finished to required levels, floated with neat cement and power trowelled to get desired smooth finish / broom finish, over a leveling course, including MS channel or box shuttering, curing for 10 days with gunny bags etc complete. The size of panel should be approximately 3.75 x 5.5 m or as directed by Engineer. The Contraction joints to be formed at every 5m distance by grooving with mechanical saw within 48 hrs. Groove/sawed joints/ longitudinal joints shall be made of 6mm width and 25 mm depth min (1/3 rd depth of the pavement) as shown in the drawing. The rate shall be inclusive of labour, making the grooves and machinery cost.
Providing material and labour for laying of Hot applied Thermoplastic compound 2.5 mm thick including Reflectorising Glass Beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC : 35 & finished surface to be level, uniform and free from streaks and holes etc complete as directed by Engineer in charge.
Supplying material and labour for fixing cat eye (Stimsonite) made out from Acrilo beautile sterine injuction high compressed molding with reflector made of MMC (prismatic type of size 12cm x 6cm x 2.5cm) provided with bituminous adhesive 100g. with each unit for fixing. (Engineer grade) etc complete as directed by Engineer in charge.
Providing material and labour for fixing rumblers strips of 500 x 100 x 15 mm of any design suggested by Architectect/ EIC like bottom design, chequered design, anti skid pattern specially designed for road grip as per drawing & sample approved by Architect which is covered with premix bituminous carpet at 1m centre to centre at approved locations to control speed marked with white strips of road marking paint etc complete as directed by Engineer in charge.
Providing material and labour for fixing Rubber Corner Guards of approved make for Concrete Pillars in Basement Parking of size 825 x 65 x 65 x 6 mm with retro reflctive tape marking in yellow colour. Corner guard shall be fixed with SS 304 grade fastner as per manufacturer's specification etc complete as directed by Engineer in charge.
Providing material and labour for fixing 600mm dia Convex mirror made out of ABS/ PC plastic of approved make having viewing distance of 6.0 Mt. fixed on wall at basement ramp as per standard and as directed by Engineer in charge.
Providing material and labour for fixing FRC (Fiber reinforcemed concrete) Heavy Duty Man Hole Cover with frame of intrnal dia 560mm with 100x2mm MS flat allround, 16mm ø plain round bar for lifting the cover & should be fitted with plastic cups etc complete as directed by engineer in charge. On the upper periphery of frame 25 x 3 mm wide MS flat with hot dip galvanizing should be well embed in concrete to protect the edges of frame.
Providing material and labour for fixing Ductile iron manhole frame and cover/ grating/ chamber cover of approved make and type. Man hole cover shall be any type (hinged type, double sealed or recess type), any shape (square/ rectangle/ square frame with round cover) any grade (light duty/ medium duty/ heavy duty) of required loading capacity having double sealed system as per manufacturing standard BS EN-124, with proper lifting arrangement, black bituminous coating, including fixing in CC and finishing etc complete as directed by engineer in charge. Cover shall be as per drawing and as per approved sample. Recess manhole cover depth shall be according to pavement/ finish as per drawing.
Providing material and labour for making tree pit with 800mm diameter NP2 class hume pipe with 600 mm height to be placed on the filled garden soil and outside area of the hume pipe to be filled with the good quality earth. Hume pipe shall be filled with the mixture of garden soil, farm yard manure and required pesticides etc. complete as directed by Engineer in charge. Excavation and soil filling shall be paid in relevant tender item.
Tree pit cover Providing material and labour for fixing tree pit cover around the tree pit, factory made exposed /fare finish precast Tree pit cover block of two halve in FRC concrete of size - 0.90Mt x 0.90Mt x 0.065mt including transporting, fixing etc. complete as directed by Engineer in charge. The rate shall also include for erecting and fixing the pieces in position as shown in the drawing with necessary equipments without ant demage. (Sample to be approved)
Providing material and labour for fixing tree guard upto height of 1.8 metre fabricated from 30 x 30 x 3mm angle and 30 x 30mm weld mesh as per drawing and details. Necessary provisions for the anchoring to floor shall be made in the tree guard. Tree guard shall be painted with two coats of yellow oxide and three coats of enamel paint as per the shade approved by EIC.
Providing material and labour for casting, hoisting, installing, Precast Reinforced cement concrete (M25) Bench of size 1500 L x 450 mm W x 450mm H with two legs of size 350mm W x 450mm H with out back rest (all elements having 125mm thick) as per design and drawing having 18mm thick mirror polished Kotastone in one piece on top. Remaing surface of table and bench shall be expose rcc work. All edges of kota shall be champhered and polished. Rate shall be inclusive of RCC, reinforcement and kota work with all material, labour for making, fixing, loading, unloading, hoisting, placing, polishing etc complete as directed by engineer in charge.
Providing material and labour for installing floor/ wall mounted dustbins of Sintex, nilkamal, Prince or equivalent. Dust bin shall be one Piece Moulded, Heavy Duty Waste Bin of approx. 80 Litres capacity made out of FDA approved virgin grades of Polyethylene material manufactured from Rotational Moulding Process/ Blow Moulding Process absolutely smooth and sanitary, chemical resistant, blended with stabilizers, Anti Corrosive, Anti Acidic, Non toxic and free from joints, welds or rims; provided with fully openable unique lid, open from either side for easy garbage drop even from distance, ideal for Storage and Handling of Solid Waste to satisfy the criticalrequirements of MSW 2000. Virgin Grade of Polyethylene material confirming to the requirement of IS 10146 – 1982. Dustbin shall be fixed on floor or wall as per approved sample and as directed by Engineer in charge.
Providing material and labour for fixing G.I. barbed wire Fencing on existing MS post provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs etc for all height all level as directed by Enginer in charge. (cost of MS posts to be paid for separately) Payment to be made per metre cost of total length of barbed wire used.
Providing material and labour for fixing in position 80 mm thick factory made machine batched & machine mixed Solid Precast RCC Rectangular Covers on cable trench of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing material and labour for placing in position 80 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Supplying mterial and labour for laying of following size DWC HDPE pipe of 63mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge.
Supplying mterial and labour for laying of following size DWC HDPE pipe of 90mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge.
Supplying mterial and labour for laying of following size DWC HDPE pipe of 120mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge.
Supplying mterial and labour for laying of following size DWC HDPE pipe of 200mm dia outer dia ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete for all depth as directed by Engineer in charge.
Providing material and labour for laying in trench reinforced concrete non-pressure IS class NP-3 pipes of 1200 mm internal diameter on RCC cradle if specified (to the level and slope) and jointing at a depth from 1.5 m to 3 m with collars and butt-ends prepared for collar joints, including filling the joints with CM 1:1 and testing them etc., complete (RCC cradle shall be measured and paid in the relevant tender items).
Providing material and labour for laying in trench reinforced concrete non-pressure IS class NP-3 pipes of 500 mm internal diameter on RCC cradle if specified (to the level and slope) and jointing at a depth from 1.5 m to 3 m with collars and butt-ends prepared for collar joints, including filling the joints with CM 1:1 and testing them etc., complete (RCC cradle shall be measured and paid in the relevant tender items).
Sec - 16 Signage Work Providing material and labour for fixing SS 304 grade brush finish 1.2mm thick Internal signage of any shape any size with letter, numbers, graphic, symbol etc made by etching with duco paint frilling/ laser print or vinyle sticker with lamination of approved make and shade. All signage plates shall be made in CNC water jet cutting, with all smoothen edges and cute round corner. Signage matter shall be as per drawing. The plate shall be fixed on brick masonry or RCC wall/ door shutter or any other flat surface with the necessary fixing like stud, fastner, self adhesive tapr or sealant/ adhesive etc complete for all floor all height as directed by Engineer in charge.
Providing material and labour for, making and fixing 4 mm thick ACP sign of any shape and size of Flexi bond or equivalent to be cut on CNC router cutting and smoothen all corners and edges. Matter shall be cut in 3M Reflective vinyl and paste on it as per design and detail and as per manufacturer's specifications. UV stabilized lamination shall be paste on it. The ACP sheet shall be fixed with clamp on MS Pole/ fixed or mount on wall/ hung from ceiling with required fastning hardware. Content of sign shall be letters (In Gujarati & English), graphics/ maps, signs etc in any colour as per design, drawing and approved by Architect and Engineer in charge. Cost of MS Structure and Civil works shall be paid as per relevant tender items. The rate shall also include cost of scaffolding, drilling, fabrication, finishing, adhesive material etc at all height and all level as directed by Engineer in charge. The contractor should submit the shop drawings based on concept design and do the sampling and get it approval before mass production.
2.0 PLUMBING WORKS PHE-01.00 Water Supply Construction of 2 Bore Wells at Site: Boring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart / bore log, including hore & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, beyind 90 metre & up to 150 metre depth below ground level. All types of soil: 300 mm diameter (2 x 150 meters = 300 meters total length)
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine / medium / coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410, mild steel, screwed and socketed / plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacturer, including required hire & labour charges, fittings and accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm (2 x 130 meters = 260 meters)
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410, plain slotted (having slot size of 1.6 / 3.2 mm), mild steel, threaded and socketed / plain bevel ended casing pipe (Type A) of required dia, conforming to IS: 8110, of reputed & approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacturer, including required hire & labour charges, fittings and accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia (2 x 20 metres = 40 meters total length)
Development of tube well in accordance with IS: 2800 (part 1) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressore, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (2 x 8 hours = 16 hours total for 2 tube wells)
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing / casing pipe, removable as per requirement, all complete for borewell of 200 mm clamp
Providing and fixing M.S. Clamp of required diameter to the top of casing / housing ppe of tube well as per IS: 2800 (part 1), including necessary bolts & nuts of required size complete. - 200 mm clamp
Providing and fixing Bail plug / Bottom Plug of required dia to the bottom of pipe assembly of tubewell as per IS: 2800 (part 1): 200 mm clamp
Supplying submersible pump set for bore of 200 mm. dia. Or more having 3 phase motor capacity about 40-45 H.P discharge capacity having (c) (6 Stage) 1600 to 1300 L.P.M. discharge at the head 81 to 102 mtrs. suitable for 100 mm dia. delivery pipe. Cat.III
Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible Submersible copper cable approved make of following size: (f) 3 Core x 16 Sq. mm.
Providing Water proof straight Joint in PVC insulated flat flexible copper cable by using insulating material, water proofing material, & making the joint complete. (B) 16 to 35 Sq. mm
Supplying of following size of HEAVY UPVC column pipe with coupler and wire lock [E] 100 mm dia
Supply of following size of TOP & BOTTOM accessories i.e. Adaptor set (CI) long, pump guard set, starter pipe Rubber ring for submersible pump & UPVC column pipe as directed by Engineer - in - charge with necessary plumbing as desired. [G] 100 mm dia
Supplying & erecting ISI Marked G.l. Union for pipe connections suitable for (G) 100 mm(4")
Supplying and erecting ISI marked sluice valve at position with necessary material for following size of pipe diameter. (G) 100 mm(4")
Supplying, & erecting C.I. swing, check type non-return (Reflux) Valve -ISI marked suitable for following size (D) 100 mm dia.
Supplying, & erecting C.I. swing, check type non-return (Reflux) Valve -ISI marked suitable for following size (B) 65 mm dia.
Supplying, & erecting C.I. swing, check type non-return (Reflux) Valve -ISI marked suitable for following size (A) 50 mm dia.
Providing, fixing, testing and commissioning C.I. body, Motorised Butterfly valve (PN10 rating) with quarter turn, on/off electric actuator, SG Iron disc with EPDM/Nitrile seat, wafer type,with panel, IP-67 water tight alluminium enclosure with postion indicator working on operated by float type level controller and manually, VOLTAGE 220V AC. B) 50mm dia.
Providing, fixing, testing and commissioning C.I. body, Motorised Butterfly valve (PN10 rating) with quarter turn, on/off electric actuator, SG Iron disc with EPDM/Nitrile seat, wafer type,with panel, IP-67 water tight alluminium enclosure with postion indicator working on operated by float type level controller and manually, VOLTAGE 220V AC. C) 65mm dia.
Providing, fixing, testing and commissioning C.I. body, Motorised Butterfly valve (PN10 rating) with quarter turn, on/off electric actuator, SG Iron disc with EPDM/Nitrile seat, wafer type,with panel, IP-67 water tight alluminium enclosure with postion indicator working on operated by float type level controller and manually, VOLTAGE 220V AC. D) 80mm dia.
Providing & fixing on line Electro-magnetic flow meter with preamplifier & microprocessor based electronic flow meter mounted adjacent to flow sensor with Modbus data output to the BMS Rack located in the Plumbing Plant Room. Device to monitor the Total Flow, Flow rate / velocity, etc. Including wiring from sensor to transmitter. Complete with all type of Plumbing & Electrical connections, accessories, wiring, & supports complete with all respect. The signal from read out shall be 4-20 m.amps to be received on BAS. The complete installation would be as per the approval and direction of the Engineer-in-charge. Electronic Flow Sensor & Transmitter – Media Clear Liquids; Line Size - as mentioned below; Display - 8 Digit for Flow Rate & 8 Digit for Flow Totalized – 16 x 2 Backlit Alphanumeric LCD; MOC: Body – SS with PU Coating; Flange: SS 316; Flow Tube: SS 304; Liner: Hard Rubber; Electrical Wire of 3 core x 1.5 Sq. mm of approved make with 6 amp 3 pin plug, Protection Class: IP 68; Earthing as per manufacturers' standards; Accuracy: 0.5%; complete. (A) 50mm diameter
Providing & fixing on line Electro-magnetic flow meter with preamplifier & microprocessor based electronic flow meter mounted adjacent to flow sensor with Modbus data output to the BMS Rack located in the Plumbing Plant Room. Device to monitor the Total Flow, Flow rate / velocity, etc. Including wiring from sensor to transmitter. Complete with all type of Plumbing & Electrical connections, accessories, wiring, & supports complete with all respect. The signal from read out shall be 4-20 m.amps to be received on BAS. The complete installation would be as per the approval and direction of the Engineer-in-charge. Electronic Flow Sensor & Transmitter – Media Clear Liquids; Line Size - as mentioned below; Display - 8 Digit for Flow Rate & 8 Digit for Flow Totalized – 16 x 2 Backlit Alphanumeric LCD; MOC: Body – SS with PU Coating; Flange: SS 316; Flow Tube: SS 304; Liner: Hard Rubber; Electrical Wire of 3 core x 1.5 Sq. mm of approved make with 6 amp 3 pin plug, Protection Class: IP 68; Earthing as per manufacturers' standards; Accuracy: 0.5%; complete. (B) 65mm diameter
Providing & fixing on line Electro-magnetic flow meter with preamplifier & microprocessor based electronic flow meter mounted adjacent to flow sensor with Modbus data output to the BMS Rack located in the Plumbing Plant Room. Device to monitor the Total Flow, Flow rate / velocity, etc. Including wiring from sensor to transmitter. Complete with all type of Plumbing & Electrical connections, accessories, wiring, & supports complete with all respect. The signal from read out shall be 4-20 m.amps to be received on BAS. The complete installation would be as per the approval and direction of the Engineer-in-charge. Electronic Flow Sensor & Transmitter – Media Clear Liquids; Line Size - as mentioned below; Display - 8 Digit for Flow Rate & 8 Digit for Flow Totalized – 16 x 2 Backlit Alphanumeric LCD; MOC: Body – SS with PU Coating; Flange: SS 316; Flow Tube: SS 304; Liner: Hard Rubber; Electrical Wire of 3 core x 1.5 Sq. mm of approved make with 6 amp 3 pin plug, Protection Class: IP 68; Earthing as per manufacturers' standards; Accuracy: 0.5%; complete. (C) 80mm diameter
Providing & fixing on line Electro-magnetic flow meter with preamplifier & microprocessor based electronic flow meter mounted adjacent to flow sensor with Modbus data output to the BMS Rack located in the Plumbing Plant Room. Device to monitor the Total Flow, Flow rate / velocity, etc. Including wiring from sensor to transmitter. Complete with all type of Plumbing & Electrical connections, accessories, wiring, & supports complete with all respect. The signal from read out shall be 4-20 m.amps to be received on BAS. The complete installation would be as per the approval and direction of the Engineer-in-charge. Electronic Flow Sensor & Transmitter – Media Clear Liquids; Line Size - as mentioned below; Display - 8 Digit for Flow Rate & 8 Digit for Flow Totalized – 16 x 2 Backlit Alphanumeric LCD; MOC: Body – SS with PU Coating; Flange: SS 316; Flow Tube: SS 304; Liner: Hard Rubber; Electrical Wire of 3 core x 1.5 Sq. mm of approved make with 6 amp 3 pin plug, Protection Class: IP 68; Earthing as per manufacturers' standards; Accuracy: 0.5%; complete. (D) 100mm diameter
Providing and fixing C.I. / D.I. Body Wafer Type Lever operated Butterfly Valve as per IS: 13095, with C.I. / D.I. disc accurately guided between two stems, integrally moulded rubber (EPDM / Nitrile) for seating to the valve disc, gasket joint with matching pipe flanges, two piece stem guided between PTFE brushes, compatible to flanges as per BS 10 Table D, rated for PN 16, having tested at 2.4 MPa (shell) & 1.76 MPa (seat), at maximum working temperature od 90 degree C. A) 80mm diameter
Providing and fixing C.I. / D.I. Body Wafer Type Lever operated Butterfly Valve as per IS: 13095, with C.I. / D.I. disc accurately guided between two stems, integrally moulded rubber (EPDM / Nitrile) for seating to the valve disc, gasket joint with matching pipe flanges, two piece stem guided between PTFE brushes, compatible to flanges as per BS 10 Table D, rated for PN 16, having tested at 2.4 MPa (shell) & 1.76 MPa (seat), at maximum working temperature od 90 degree C. B) 65mm diameter
Providing and fixing Gun metal check or non-return fullway wheel valve.(A) 15mm dia.
Providing and fixing Gun metal check or non-return fullway wheel valve.(B) 20mm dia.
Providing and fixing Gun metal check or non-return fullway wheel valve.(C) 25mm dia.
Providing and fixing Gun metal check or non-return fullway wheel valve.(D) 32mm dia.
Providing and fixing Gun metal check or non-return fullway wheel valve.(E) 40mm dia.
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (c) 32mm dia nominal bore.
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (e) 50mm dia nominal bore.
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (f) 65mm dia nominal bore.
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (f) 80mm dia nominal bore.
Providing and fixing Cast Steel (A 216 Gr. WCB) Gate Valve Class-150 (Flanged) (g) 100mm dia nominal bore.
Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Ashirvad / Equivalent. b) 20 mm nominal bore
Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Ashirvad / Equivalent. c) 25 mm nominal bore
Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Ashirvad / Equivalent. f) 50 mm nominal bore
Providing and fixing PVC Ball valves with S.S. 304 ball valve on EPDM seat, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Ashirvad / Equivalent. g) 65 mm nominal bore
Providing, fixing, jointing, testing and commissioning of Pressure Reducing Valve Set for cold water supply comprising of 2 Nos Gun Metal ball valves on inlet & outlet & 01 no. Globe valve for by-pass, 01 No. Brass housing diaphragm operated Pressure Reducing Valve with flanged / screwed connection, with in-built SS 316 Filter with filter opening size 0.8 mm or lower, 1 Nos Pressure gauge on outlet, and 1 No. 15 mm dia safety valve. The complete system is tested to a pressure not less than 10 Kg/Sq.cm Including necessary pipe & fittings; i.e. flanges/ unions, nuts, bolts and washers complete as required. (installed on cold water make up line to Hot water mixing tank) with all necessary accessories, as per specification/drawings and as directed by Engineer In Charge. Note: The PRV shall be installed in an accessible location. Inlet Pressure: Max. 10 Kg/Sq.cm Outlet Pressure: 2.5 Kg/Sq.cm 25 mm dia (Brass Housing - PRV)
32 mm dia (Brass Housing - PRV)
50 mm dia (Brass Housing - PRV)
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (18.12.6 - 50 mm Dia nominal bore)
Providing and laying in trenches galvanised Mild Steel tubes (medium grade) of the following nominal bore, and tube fitting (Earthwork in trenches to be measured and paid for separately) (E) 65mm
Providing and laying in trenches galvanised Mild Steel tubes (medium grade) of the following nominal bore, and tube fitting (Earthwork in trenches to be measured and paid for separately) (H) 80mm
Supplying ISI Marked (Embossed) following size of Heavy duty “C” Class G.I . Pipe & erecting as directed by Engineer-in-charge with necessary plumbing as desired. (G) 100 mm dia.
Making connection of galvanized Mild Steel distribution branch with galvanized mild steel main 50mm to 80mm nominal bore by providing and fixing tee including cutting and threading the pipes complete.
Supplying & erecting approved make Automatic liquid level controller 6A.as per instruction of Engineer in charge on site complete with wiring connection with existing wires , with copper conductor from pump to upper and lower tank.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [A] 15 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [B] 20 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [C] 25 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [D] 32mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [E] 40mm.
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (ii) 20 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (iii) 25 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (iv) 32 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) (Sch-40) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (vi) 50 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) (Sch-40) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (vii) 65 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) (Sch-40) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (viii) 80 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) (Sch-40) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (ix) 100 mm nominal outer dia pipes
Providing and Fixing vitreous china extended wall mount water closet (EWC) as per IS: 2556 (Part 2) of size 610 x 370 x 320mm (P Type) including seat and cover as per IS: 2548 of approved make and quality, and as approved by Engineer-in-charge, including all necessary fittings and accessories, complete. (II) Type 2 - Hindware - Flora - Model # 20098 / Equivalent
Providing & fixing C.P. brass Concealed type flush valve (Metropole Flush Valve) with, 25 mm dia C.P. flush pipe with clamp and adapter, rubber joint, C.P. brass wall flange, elbow complete with all other accessories. Make: Jaquar - FLV-1085N or Equivalent
Providing, fixing, testing & commissioning of Single Piece Concealed cistern Floor mounting frame, installation kit and "P" type drain pipe connection set for Wall Hung WC, with dual flush 3/6 ltr with wall flush plate of approved make and push fit flexible hose complete including cutting and making good the walls where required complete as directed by Engineer-in-charge. Make: Jaquar - JCS-WHT-2431FP + Dual Flush Plate - JCP-2415 / Hindware - Concealo - 511725 + Dual Flush Plate - Loop - 508178 / Equivalent
Providing and fixing 8mm dia C.P. / S.S. jet with flexible tube up to 1 meter long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer-in-charge.
Providing and fixing ABS Chrome plated Brass Hand Shower (Health Faucet) of approved make and quality and as approved by Engineer - In - Charge, including 8 mm dia, 1 Meter long Flexible tube & wall hook including cutting and making good the walls wherever required complete as per directions of the Engineer-in-charge. Make: Jaquar - ALD-573GA or Equivalent of the same make.
Providing & fixing Divyang toilet set with European Closet (P Trap) & wall mount wash basin & all divyang requirements with dual flush tank, seat & lead (heavy duty) including C.I. Brackets, C.P. brass hinges, M.S. / C.I. painted brackets, 32mm CP waste Coupling, 32mm size CP bottle trap, CP brass Spatula Faucet, etc. all Internal fittings complete with S.S grab rails etc. rubber buffers, C.P nuts, bolts etc making holes in walls & floors, & finishing for ready to use.The rate includes all necessary connection charges as per product detail to the satisfaction and as directed by the Engineer-in-charge. Make: Hindware - Matrix - 70002 Set of WC, Wash Basin, Grab Bars; Make: Jaquar - Spatula Faucet - FLR-5093N; Make: WaterTech / Prayag - PTMT wastecoupling & bottle trap. Divyang Set: Make - Hindware - Matrix Set - 70002; Long Handle Basin Cock: Make: Jaquar - Florentine - FLR-5031 N / Equivalent.
Providing and fixing white vitreous China semi-recessed washbasin with single hole for pillar tap fitted over the counter with required and appropriate silicon sealant and making good the same, including pillar tap, braided hose, 32mm waste coupling, 32mm CP brass bottle trap, complete as per the direction and approval of the Engineer in charge. Size: 520 mm x 460mm x 160mm depth. Wash Basin - Make: Hindware - Enigma - #91012; Pillar Tap - Make: Jaquar - VGP-81011B ; Waste Couling - Make: Jaquar - ALD 705L130; Bottle Trap - Make: Jaquar - ALD 769L250x190
Providing and fixing white vitreous China overcounter washbasin with single hole for pillar tap fitted over the counter with required and appropriate silicon sealant and making good the same, including pillar tap, braided hose, 32mm waste coupling, 32mm CP brass bottle trap, complete as per the direction and approval of the Engineer in charge. Size: 380 mm x 380mm x 130mm depth. Wash Basin - Make: Hindware - Fabio - #10104; Pillar Cock with neck aerator - Make: Cera - F3002103; Waste Couling - Make: Cera - F8050301; Bottle Trap - Make: Cera - F8060301
Providing and fixing Flat Back Large Urinal of approved make and quality including conecting the Urinal with waste pipe , pressmatic flush valve, spreader, including fixing to wall with C.P. brass screws, rawl plugs, etc. complete. Make: Hindware - Flat Back Large of size 610 x 410 x 380mm - 60002 / Equivalent.
Providing and fixing washbasin with single hole for pillar tap with C.I. or M.S. brackets painted white including cutting holes and making good the same but excluding fittings. (A) Vitreous China: (ii) Flat Back washbasin 550 mm x 400 mm size. (i) In white colour.
Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required: 17.10.2 - Kitchen Sink without drain board Size: 610 x 510 mm bowl depth 200mm
Providing and fixing C.P. brass Side single lever sink mixer with swinging spout (table mounted) with 450mm long braided hoses, of approved make and quality, and as approved by the Engineer-in-charge, and conforming to Manufacturers Standards. Make: Jaquar - Florentine - FLR-5179B / Equivalent.
Providing and fixing white vitreous china laboratory sink of size 600x450x200 mm with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required as directed by Engineer-in-charge.
Providing and fixing C.P. brass waste for washbasin or sink. (A) 32mmdia.
Providing and fixing C.P. brass waste for washbasin or sink. (B) 40mm dia.
Providing and fixing toilet paper holder.(A) C.P. Brass
Providing and fixing screw down bib taps of following size.(B) Brass chromium plated screws down Bib Tap. (i) 15mm dia.
Providing and fixing of 15mm nominal bore CP Brass Angle valve confirming to IS: 8931, for wash basins, water coolers, geyser points, etc of approved quality and as approved by and directed by the Engineer-in-charge.
Providing and Fixing 15 mm dia. CP brass two way bib cock with wall flange and ceramic disc cartridge complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. Make: Jaquar-FLR-5041NG or Equivalent of the same make.
Providing and Fixing 15 mm dia. CP brass extended lever handle pillar cock with ceramic disc cartridge for all laboratory sinks or as directed by the Engineer-in-charge, complete, making all necessary connections etc of approved make. Make: Jaquar-Florentine - FLR-5031 N / Equivalent.
Providing and Fixing 15 mm dia. Wall mounted type CP brass pressmatic bib cock with Auto Closing System with Built-in Control Cock With Wall Flange complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. Make: Jaquar-PRS-043 / Equivalent.
Providing and fixing 15 mm diameter Pillar Cock with lift tye operating knob & base flange of approved make and quality and as approved by Engineer - In - Charge, including 600 mm long braided hose with M10X1 Nipple, 15mm nut, O-ring & rubber washer, including cutting and making good the counters wherever required complete as per directions of the Engineer-in-charge. Make: Jaquar - Pillar Cock - Florentine - FLR - 5015; Braide Hose Pipe - ALD-801B / Equivalent.
Providing and fixing pillar tap, capstan head, screw down high pressure with screws, shanks and back nuts. (i) 15mm dia.
Providing and Fixing in position CP brass Pressmatic Urinal Flush Valve Auto-closing system with built in Control Cock and Wall flange of approved or equivalent make, including 15mm diameter x 200mm long S.S. pipe connection with Urinal and spreader, and including all necessary materials required for fixing. All complete as per directions of the Engineer-in-charge. Make: Self Closing pressmatic angle cock: Cera - F9020203; Spreader - F8070201 / Equivalent.
Providing and fixing chromium plated, bottle trap with necessary couplings of approved quality for wash basin.
Providing and Fixing SS Liquid Soap Dispenser of approved make and quality, and as approved by the Engineer-in-charge, including all necessary materials required for fixing. All complete as per directions of the Engineer-in-charge. Make; Jaquar - ACN-1137N / Equivalent
Type 1 - Size 129mm x 129mm Square Matt finish with Cockroach trap consisting of 104mm diameter (101mm) perforated top cover, 77mm Ø x 70mm high Cockroach Trap ideal for 100mm drain pipe with floor trap cover as specified in approved make and quality. Make: Chilly - Square Gypsy: Model No: CCT-SG-129 / Equivalent.
Type 2 - Size 150mm x 150mm Square Matt finish with Cockroach trap consisting of 100mm diameter solid top cover, 77mm Ø x 70mm high Cockroach Trap ideal for 100mm drain pipe with floor trap cover as specified in approved make and quality. (For Urinal only) Make: Chilly - Lifestyle Square : Model No: CCTL-S-150 / Equivalent.
Providing and fixing ball cock of approved. quality as directed.(B) Abonite (ii) 50mm dia.
Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size having weight not less than 35Kg.
Providing and fixing G.I. Rain water spout of 50mm dia. and 30cm. length.
Providing and fixing of self cleansing P Trap, in Structured Wall UPVC non pressurized wastewater piping as per IS: 14735, of size 110mm x110mm with solvent cement welding, complete, including cost of cutting and making good the walls and floors. Make: Astral / Ashirvad / Prince.
Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
Providing, laying and jointing in true line and level 75 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Make: Astral / Ashirvad / Prince.
Providing, laying and jointing in true line and level 50 diametre P.V.C (6kg/cm2) conforming to IS 4985 with single socket, & fittings of approved make for drainage system pipe line, pipe shall be jointed with each other with appropriate solvent cement, pipe shall be shall be concealed in walls as directed, including necessary fittings such as bends, shoes etc. including testing of pipes and joints, including cost of all materials. Make: Astral / Ashirvad / Prince.
Providing, laying and jointing in true line and level 40 diametre PVC (6kg/cm2) conforming to IS 4985 with single socket, & fittings of approved make for drainage system pipe line, pipe shall be jointed with appropriate solvent cement, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints, including cost of all materials. Make: Astral / Ashirvad / Prince.
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 75 mm diameter with jali of the following nominal diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making good the walls.
Providing and fixing unplasticized PVC SWR as per IS: 13592 (Type B), vent cowl as approved and directed by the Engineer-in-charge. For 110 mm Dia pipe. Make: Astral / Ashirvad / Prince.
Providing and fixing unplasticized PVC SWR as per IS: 13592 (Type B), vent cowl as approved and directed by the Engineer-in-charge. For 150 mm Dia pipe. Make: Astral / Ashirvad / Prince.
Providing, laying and jointing in true line and level 150 diametre U.P.V.C (Type A) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Make: Astral / Ashirvad / Prince.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised-PVC rain water pipes conforming to IS : 13592 (Type A), including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe Bend - 110mm dia pipe
PHE 03.00 Drainage Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps.(B) 150mm x 100mm size P or R type
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(B) 150mm (upto 10 ton)
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(C) 250mm (upto 10 ton)
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(D) 300mm (upto 10 ton)
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(E) 450mm (upto 10 ton)
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(G) 600mm (upto 10 ton)
Providing and erecting at the site of work steel ventilating column of 150m internal diameter and 12.20 Metre High from G.L. to bottom of top grill including C.I. grill and base plate bolts and nuts etc. and excavation in foundation of size 120cm. x 120vcm. x 165cm. and filling the pit with first layer of cement concrete 1:3:6 mix (1-cement :3-coarse sand :6-graded stone aggregate 20mm nominal size) of 120cm. x 120cm. x 90cm. and remaining pit with B.B.C. 1:3:6 mix (1-cement :3-coarse sand:6-Brickbats 40+50mm size) and providing fillet in Cement concrete 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm. nominal size) at G.L. and 3 coats of silver paint etc. complete. (upto 10 ton)
Constructing brick masonary chamber for under ground C.I. Inspection Chamber and bends with bricks having crushing stregth no less then 35 kg/cm2 in C.M 1 :5 having C.I. cover with frame (light duty) of size 455 mm x 610 mm internal dimension total weight of cover with frame to be not less than 38 kg (Wt. of cover 28 kg, Wt. of frame 15 kg), R.C.C. top slab with 1: 2 : 4 mix (1 Cement : 2 coarese sand : 4 grade stone aggregate 20 mm size) foundation concrete 1:5:10 inside plaster 15 mm thick with cement mortar 1 : 3 finished smooth with a floating coat of neat cement on walls and bed concerete etc. complete. (iii) Inside dimension 600 mm x 850 mm and 450 mm deep for pipe line with three or more inlets.
Constrcting Manhole with R.C.C. top slab in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm. nominal size), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 Brick bats 40 to 50 mm. size) inside plastering 15mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20mm nominal size) finished smooth complete including curing and testing. (i) Inside size 900mm x 1200 mm and 1.50 meter deep including heavy duty FRC Manhole frame and cover of size - 560 diameter total weight of cover and frame to be not less than 128 kgs (Wt. of cover 64 kg and Wt. of frame 64 kg) (A) with 230 mm thick walls of brick masonary using bricks having crushing strength not less then 35 kg/sq.cm in cement motar 1 : 5 (1 cement : 5 coarse sand) (1) A type depth 0.9 metre for 150 mm diameter sewer.
(I) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over item No.24.27 (I) for depth from 0.9M to 1.5M.
Constrcting Manhole with R.C.C. top slab in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm. nominal size), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 Brick bats 40 to 50 mm. size) inside plastering 15mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20mm nominal size) finished smooth complete including curing and testing. (i) Inside size 900mm x 1200 mm and 1.50 meter deep including heavy duty FRC Manhole frame and cover of size - 560 diameter total weight of cover and frame to be not less than 128 kgs (Wt. of cover 64 kg and Wt. of frame 64 kg) (A) with 230 mm thick walls of brick masonary using bricks having crushing strength not less then 35 kg/sq.cm in cement motar 1 : 5 (1 cement : 5 coarse sand) (2) B type depth 1.50 metre for 150 mm diameter sewer.
(I) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over item No.24.27 (I) for depth from 1.5M. to 2.25M
Constructing brick masonry road gully chamber 500mm x 450mm x 600mm including 500mm x 450mm C.I. horizontal grating with frame complete.
Constructing brick masonry road gully chamber 1100mm x 500mm x 775mm including 500mm x 450mm C.I. horizontal grating with frame complete.
PHE 04.00 Equipments Water Treatment Plant: Supply, Installation, Testing and Commissioning of water treatment plant having Ultra-filters, Micro-cartridge filters, Resin Treament, Anti-scalant treatment, or any of these in a combination to provide scaling free water to all buildings within the campus, including centrifugal multistage water pump (1 working + 1 standby), connected plumbing work, control panel for auto cutoff, auto on, auto regeneration, auto rinse and auto filter mode (1 working + 1 standby) with IP55 protection with all necessary equipment, piping and connected activities as per specification and operating conditions as mentioned by manufacturer or as directed by engineer in charge. System Capacity: 330,000 litres per day. Make: Aquila RO Systems Pvt Ltd / Linc Digital (Ion Exchange) / Cleantech Water.
DRAINAGE SUMP PUMP: Providing and fixing compact monoblock dry motor submersible pumps of suitable rating, with non-clog free flow open impeller, solid handling capacity of upto at least 28mm suitable for operation on 415 volts +10% , 3 Phase, 50Hz, A.C supply, speed 2900 RPM including oil chamber, guide wire for lifting & lowering of pump, M.S. galvanized lifting chain, duck foot bend complete. The pump sets shall be supplied with required accessories & as per specification with the following : (a) Complete piping 80 mm dia common delivery upto 7.5 m in heavy Duty Class 'C' G.I. -- 1 Set (c) 65 mm dia Flap type Non-return valve.-- 2 Nos (d) Necessary cables from pump set to control panel (position of panel marked on enclosed drawings).- 1 Set (e) Electrical control panel having all necessary accessories & safety devices of standard specifications and suitable for receiving incommer cable to conncet complete. (Panels with sump pumps near each sump as per site conditions). --1 No. (f) Each set consist of 2 nos.of pumps - 1 working & 1 stand by (Complete set as above with 2 nos. pumps including cost for valves, piping, Control Panel and Cabling, Level Controllers etc as required and as specified) 2.The entire system alongwith pumps & control panel must be sourced from single manufacturer only for unit responsibility. Discharge: 15 Cu. Mtr / Hr Head: 10 Meter (minimum)
Hydro-pneumatic System - for Zone 2: Supply, Installation, Testing And Commissioning Of Compact Self Contained Skid Mounted Hydropneumatic System as follows: Design, engineer, procure, supply, test and commission a pre-engineered, factory fabricated, assembled & tested, fully integrated, highly efficient pump, IE2 motors, skid mounted, complete ready-to-connect packaged variable speed water pressure booster station. The packaged variable speed water pressure booster station shall be complete with vertical multi stage centrifugal pumps connected in parallel, high efficiency IE 2 motors, an air-cooled external variable frequency drive, intelligent multi-pump controller, the controller shall be mounted in a control cabinet with an IP 41 enclosure of suitable rating having Potential free contacts to monitor On/Off & Trip status with necessary sensors/switches; hot Dipped Galvanised suction and delivery manifolds; isolation ball valves on suction and discharge of each pump; non return valve on discharge side of each pump; hot dip galvanised common base frame; and diaphragm pressure vessel. Complete (Skid mounted / wall mounted / floor mounted) electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (list to be provided by the vendor). All installations such as electrical wiring from Electrical Panel to Pump panel, civil foundations, etc is included in this scope. Set of accessories such as NRVs, isolating valves, Hot dip Galvanized Iron suction and delivery header, pressure gauge, GI base frame, pressure switches, pressure transducers, inter connecting power and control cabling etc. complete. For Zone 2: Residential Soft Water Supply (3 W + 1 S) Flow Rate (Each Pump): 286 LPM Head (Each Pump): 87 MTRS Flow Rate (System): 858 LPM (51.5 Cu. Mtr / Hr)
For Zone 2: Residential Soft Water Supply (3 W + 1 S) Flow Rate (Each Pump): 167 LPM Flow Rate (System): 500 LPM (30 Cu. Mtr / Hr) Head (Each Pump): 87 MTRS
Hydro-pneumatic System - for Zone 1: Supply, Installation, Testing And Commissioning Of Compact Self Contained Skid Mounted Hydropneumatic System as follows: Design, engineer, procure, supply, test and commission a pre-engineered, factory fabricated, assembled & tested, fully integrated, highly efficient pump, IE2 motors, skid mounted, complete ready-to-connect packaged variable speed water pressure booster station. The packaged variable speed water pressure booster station shall be complete with vertical multi stage centrifugal pumps connected in parallel, high efficiency IE 2 motors, an air-cooled external variable frequency drive, intelligent multi-pump controller, the controller shall be mounted in a control cabinet with an IP 41 enclosure of suitable rating having Potential free contacts to monitor On/Off & Trip status with necessary sensors/switches; hot Dipped Galvanised suction and delivery manifolds; isolation ball valves on suction and discharge of each pump; non return valve on discharge side of each pump; hot dip galvanised common base frame; and diaphragm pressure vessel. Complete (Skid mounted / wall mounted / floor mounted) electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (list to be provided by the vendor). All installations such as electrical wiring from Electrical Panel to Pump panel, civil foundations, etc is included in this scope. Set of accessories such as NRVs, isolating valves, Hot dip Galvanized Iron suction and delivery header, pressure gauge, GI base frame, pressure switches, pressure transducers, inter connecting power and control cabling etc. complete. For Zone 1: Academic Soft Water Supply (3 W + 1 S) Flow Rate (Each Pump): 250 LPM Flow Rate (System): 750 LPM (45 Cu. Mtr / Hr) Head (Each Pump): 67.5 MTRS
For Zone 1: Academic Recycled Water Supply: (2 W + 1S) Flow Rate (Each Pump): 167 LPM Flow Rate (System): 500 LPM (30 Cu. Mtr / Hr) Head (Each Pump): 67.5 MTRS
Hydro-pneumatic System - for all buildings (terrace): Supplying and erecting Fully Automatic hydro pneumatic booster system with cast iron housing Enclosure class IP44 minimum , with built in PTO motor protection and stainless steel impeller pump, pump modelGRUNDFOS CMB 5-46 series or equivalent with 24 Liter hydro pneumatic pressurized tank capacity 8 m3/hr,Rated head :40 mtr, motor rating : 1.5 H.P. includes pressure switches, Non Return Valve, Pressure Gauge, 5 way Brass connector, with necessary Plumbing work of 25mm dia suction and delivery pipe which includes all required size of pipes, Joints valves, Bypass valve, labor all accessories required for installation of pressure pump ( Foundation work and base stand cost included)
Sewage Treatment Plant: Supply, installation, testing & commissioning of Sewage Treatment Plant MBR Type (Package Treatment Plant) of 230 kLD with collection tank, primary, secondary & tertiary treatment also with all electromechanical equipments, interconnected piping, valves, pumps, instruments, gauges, electrification like panel, starter, cabling, earthing, etc. complete. The sizing of tank/equipment shall take care of average as well as peak flow. The outlet parameters shall be as per specifications.(Including civil cost of Bar Screen Chamber) (Cost of civil works for tanks not included). The entire system shall be installed, all relevant approvals from local and other authorities to be procured, submitting of the reports, certificates, etc as per norms and requirements, training of staff, handing over all relevant documents, etc complete as directed and approved by the Engineer-in-charge. Make: Linc Digital (Ion Exchange) / Equivalent
Drinking Water Fountains: Supply installation, testing and commissioning of recessed bi level drinking water fountain, with double ss finish bubbler and one alcove bottel filling station with sensor and mechanical operation Drinking water fountain with 8GPH cooling capacity, stainless steel body ,approx size 1003mmX Depth 400 mmX hight 1162mm, ss bubbler guard operated between 50 to 120 PSI, chilling unit suitable for R134a refrigerant, adjustable thermo state,With MDCU29, supply complete with all accessories.R-134a refrigerant. Shall comply with ANSI 117.1 and ADA. Shall be listed by Underwriters Laboratories to US and Canadian standards, GRIHA Certifide (Green Rating for Integrated Habitat Assessment), TUV-SUD Certifide and shall comply with ANSI/NSF 61 and NSF/ANSI 372. Make: Oasis - Aqua Pointe M8CRSBFY -Cooling- with Touchless operations / Make: WAE: DWF NT02.SB.CH + WAE DWF LEGACY.SB.BF / Equivalent
Supplying & erecting 5 stage single reverse osmosis water purification system with M.S. powder coated frame, prefilter housing with 'O' ring presediment filter GAC filter, carbon filter suitable buster DC pump capacity 80 psi, mention with 40 psi inline type post carbon filter auto low & high pressure switches with following size of storage tank & LPH capacity & erected as directed with one year comprehensive maintenance guarantee. [C] 50 Ltr / Hr with 250 psi 2 nos booster pump
Sec. 3.0 Electrical works ELW 01.00 HT PANEL Supplying, Testing & Commissioning of 1 no.400A HT VCB as incomer and 2 nos 400A HT VCB as outgoings .The panel should have tinned copper busbars and extensible type for future requirements. This should be complete with metering and protection and complete in all as per specification. Panel must be extensible type.
ELW 02.00 Transformer Supplying, Installtion,Testing, Commissioning & unloading at site, shifting to the erection site assembling, leveling, grouting, installing, field testing and commissioning of 1000KVA Dry type Transformer with on load tape changer with OLTC and RTCC. +10% to -10% in step of 1.25%. Maximum Losses must be 4.5 kW at 50% load & 12 kW at 100% load, Z% - 5% maximum, Scope also includes connection between OLTC and RTCC. Complete in all respect as per specification.
ELW 03.00 Substation Equipment and substaion Auxiliary Providing and erecting ISI Marked 3core 240 Sq.mm XLPE insulated 11 KV armoured, unearth cable Aluminium conductor IS-7098 to be laid on wall with clamps or in provided cable trench / pipe approved manner as directed.
SITC of H.T. cable indoor type end connection for 11 KV XLPE, 240 sq mm x 3 core cable
Suppplying & Erecting automatic emergency light with maintenance free battery for 2 X 18 watts CFL tube. With exide make battery
Supplying & Erecting Rubber mat 1.1 KV grade ISI marked 1000 x 1000 x 4 mm size.
Supplying & Erecting Rubber mat 11 KV grade ISI marked 1000 x 1000 x 12 mm size.
Providing and erecting danger notice board for high voltage installation to be erected as per I.S.
Providing printed instruction chart both in English & REGIONAL LANGUAGE & duly framed out on glass for treatment of person suffering from Electric shock.
Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply.
Supplying Standard First aid box with all the Standard contents.
Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and Red out side with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall hook..
Supplying & Erecting 1.5 mtr. (5') x 0.9 mtr. (3.1') x 0.6 mtr. (2.1') Floor mounted stand (For keeping 4 Nos.of buckets) made of 30 x 30 x 4 mm. angle iron welded with 4 hooks and duly painted with one coat of red lead & two coats of Approved enameled silver paints.
Supply installation testing and commissionning of Wall hooks of 22 to 25 cms. projection for keeping fire buckets made out of 15 mm. dia M.S. rod grouted in wall to a depth of minimum 15 cms.
ELW 04.00 MV Switch Gear And Power Panel Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. MAIN PANEL AT SUBSTATION As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. EMERGENCY POWER PANEL AT SUBSTATION As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. 210 kVAR APFCR PANEL As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. EMERGENCY POWER PANEL_ACADEMIC BUILDING As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. RHS POWER PANEL@GF_ACADEMIC BUILDING As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect UPS PANEL_ACADEMIC BUILDING As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. EXTERNAL LIGHTING PANEL (OUTDOOR DUTY) As per Single line diagram
ELW 05.00 DG Set with AMF panel Supplying, installation, testing and commissioning of DG set of 1 # 500 KVA with approximate 602 BHP engine with enclouser & suitable alternator complete with all necessary fuel piping,Aluminium cladding, exhaust piping, control panel, Auto synchronizing, auto load sharing AMF Panel, silencer & its piping, Acoustic silencer, Alternator cable termination box suitable for Aluminium cables,initial battery charging,base frame, battery and charger complete in all respect. Scope also includes preparing necessary drawing submitting to authorities, getting their approval / sanction and final certificate including NOC from pollution board(if required) to energize the D G Set . (Rate Includes 1 Nos. of 500 kVA Dg sets, 1 Nos. Control & AMF Panels and 1 No. of Auto synchronizing Panel etc. -Please refer Specification for Auto Sycn. Panel)
ELW 06.00 Distribution Board DISTRIBUTION BOARD Supplying, assembling, grouting, levelling, installation, Connecting & testing D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement. TPN Distribution Board : Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 12 SPMCB as outgoing per phase (i.e. 16 way TPN D.B.) with 16 way PPI kit
Supplying, assembling, grouting, levelling, installation, Connecting & testing D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement. Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 8 SPMCB as outgoing per phase (i.e. 12 way TPN D.B.) with 12 way PPI kit
Supplying, assembling, grouting, levelling, installation, Connecting & testing D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement. Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 4 SPMCB as outgoing per phase (i.e. 8 way TPN D.B.) with 8 way PPI kit
Supplying, assembling, grouting, levelling, installation, Connecting & testing D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement. Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 2 SPMCB as outgoing per phase (i.e. 6 way TPN D.B.) with 8 way PPI kit
SPN Distribution Board : Supplying, erecting, testing and commissioning of SPN D.B. with space for DPELMCB as incoming and 12 SPMCB as outgoing per phase (i.e. 16 way SPN D.B.
upplying, erecting, testing and commissioning of SPN D.B. with space for DPELMCB as incoming and 8 SPMCB as outgoing per phase (i.e. 12 way SPN D.B.)
VTPN Distribution Board: Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush / surface mounted double door (IP54) fitted with insulated copper busbar, isolated neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986,IP-54 suitable for 63/100 AMP TPN MCCB + RCCB as incomer and three phase outgoing as per following .(The DBs should be used of same company of MCB to be used) 8 way outgoing
MCB 's and its Accessories Supplying, Assembling, levelling, connecting & testing following MCB / ELMCB / MCCB etc in boards as specified in 8.1, 8.2. Miniature circuit breaker single pole 6A to 25A. suitable to operate on 240V. A.C. system and having breaking capacity 10 KA to be erected in existing box. Confirming to IS 8828 / 1996 with ISI Mark.
Providing & erecting 240V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS: 8828 in existing box having following capacity. 6 to 32 A DP MCB
SITC of 6A / 10A / 16A / 20A / 25A DP RCBO (RCCB+MCB) (30mA)
SITC of 32 / 40 A DP RCBO(RCCB+MCB) (30mA)
SITC of 32 A DP RCBO(RCCB+MCB) (100mA)
SITC of 40 A DP RCBO(RCCB+MCB) (100mA)
SITC of 63 A DP RCBO(RCCB+MCB) (30mA)
SITC of 63 A DP RCBO(RCCB+MCB) (100mA)
SITC of 63 A FP RCBO(RCCB+MCB) (300mA)
SITC of 6 to 32 A TP MCB
SITC of 6 to 32 A FP MCB
SITC of Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB.
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs Single doop IP30 4 way
Surge Protection Devices (SPD) Supplying, Assembling, levelling, connecting & testing following VSPs etc in boards 1.2KV Protection level FP, Class 's', (Imax-15KA, 8/20µS) Cat 003954
Surge Protection Devices (SPD) Supplying, Assembling, levelling, connecting & testing following VSPs etc in boards 1.2KV Protection level DP, Class 's', (Imax-15KA, 8/20µS) Cat 003974
SITC of Blank Plates
Caution Board : SITC of Caution boards of size 150 x 150 mm. to be supplied & fixed on the D.B.
MCCB SITC of 100 A FP MCCB with Sheet steel metal enclouser
SITC of 125A FP MCCB with Sheet steel metal enclouser
ELW 07.00 MV Cabling CABLES Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 400 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 300 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 240 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 185 Sq.mm x 3.5C Al. Cable
Supply, testing and Layingand commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 150 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 120 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 95 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 70 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 50 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 35 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 25 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 16 Sq.mm x 4C CU. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 10 Sq.mm x 4C CU. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 6 Sq.mm x 4c CU. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 4 Sq.mm x 4c CU. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 4 Sq.mm x 3c CU. Cable
ELW 08.00 Cable Termination Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 400 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 300 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 240 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 185 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 150 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 120 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 95 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 70 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 50 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 35 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 25 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 16 Sq.mm x 4C CU. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 10 Sq.mm x 4C CU. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 6 Sq.mm x 4C CU. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 4 Sq.mm x 4C CU. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 4 Sq.mm x 3c CU. Cable
ELW 09.00 Cable Tray Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 150 x 100 made out of 2 mm thick ladder type
Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 150 x 50 made out of 2 mm thick ladder type
Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 300 x 100 made out of 2 mm thick ladder type
Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 450 x 100 made out of 2 mm thick ladder type
Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 600 x 100 made out of 2 mm thick ladder type
Supply & Installation of hot dip GI perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 150 x 100 made out of 2 mm thick perforated type
Supply & Installation of hot dip GI perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 300 x 100 made out of 2 mm thick perforated type
Supply & Installation of hot dip GI perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 450 x 100 made out of 2 mm thick perforated type
Supply & Installation of hot dip GI perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 600 x 100 made out of 2 mm thick perforated type
Supplying , fabricating and installation of various sizes clamps for cable tray supports using available M.S. sections & rod as per drawings or instructions of engineer in charge or consultant including applying zinc chromate yellow oxide and two to three coats of required enamel paints with anchor fasteners etc.
ELW 10.00 Internal Wiring WITH MODULAR TYPE SWITCHES Wiring of points to be done in open/concealed manner in 25 mm dia medium guage Rigid PVC FRLS pipe. Wiring shall be done with FRLS type copper flexible wire of 650V/1100V. Separate pipe should be taken for circuit mains. Nos of ciruit of the same phases may be taken in same conduit .The circuit shall be laid in 25/40 mm dia medium guage rigid PVC FRLS pipe.The point rate shall include all the necessary piping and wiring from sub panel / Distribution board to switch board & switch board to the batten holder / angle holder / connector / ceiling rose all inclusive except sub panel / Dist board. The wiring shall be done as per relevant prevailing standard. The looping of the wiring should be done in the switch boxes or light and fan point outlet boxes to avoid the junction boxes. The junction boxes and switch boxes for the ceiling light point, fan point etc shall be minimum 60/75 deep. All the necessary jarry in brick plastered walls should be done with machine cutter only , also jarry should be filled with cement, sand and wire mesh as required, the material cost for rough finish shall be included in point rate.Whenever pipes are required to be laid in flooring shall be of.Wiring should be done as per distribtion details. Each circuit should have dedicated phase, neutral & earth wire. Wire sizes to be used as under For Light Points /fan point/ wall fan / 6A 3 Pin Plug - DB to SB - 2.5sqmm for Phase & Neutral & 1.5 sqmm for Earth - SB to on board Point - 1.5 sqmm for Phase & Neutral & Earth For 6A Plug point. - 1.5 sqmm for Phase, Neutral & Earth For 6/10/16A general purpose plug point - 2.5 sqmm for Phase, Neutral & 1.5 sqmm Earth For 16A plug point for A/C and Geyser - 4 Sqmm for Phase, Neutral & 2.5 sqmm Earth For 20/32A plug point - 6 sqmm for Phases, Neutral & 4 sqmm Earth No zarry will be allowed in expose brick work. The conduit shall be provided when the walls are under construction. The pipes in slab shall be laid before the slab is casted. One light point controlled by one single way 6 A switch.
Loop light point to be controlled from same switch.(Looping from first point)
One light point controlled by two, two way 6 A switch
One ceiling fan outlet point controlled by one 6 A switch and hum free electronic type step regulator and cast iron fan box.
One 6 A x 5 pin 250 Volt universal socket outlet point controlled by one 6 A switch located on switch board.
6 A x 5 pin 250 Volt universal switched socket outlet point at convenient location.
6/16 A x 250 V switch socket point on one switch box with 2.5 sqmm flexible wires and phase and neutral and 1.5 sq nm flexible Cu. wire as earth wire. The rate should include conduiting upto DB.
6/16A x 250 Volt switched socket outlet point for body storage with 4 sq.mm wire for phase and neutral & 2.5 sq.mm earth wire.
-Do- as above but switch and socket at different location
Exhaust fan outlet point with 6A 5 pin socket controlled by one 5 single way switch located at different location.
Bell point controlled by Bell push switch with Buzzer / bell of approved make.
SITC computer power supply point with 2 nos of 6 amp 5 pin socket with 1 no. of 6/16 Amp. socket with 1 no 16 A Switch with indicator & wiring of computer point will be done through 2 nos.of 2.5 sq. mm Cu. wires as phase & Neutral and 1 nos. of 1.5 sq.mm.as earth wire. .( This cost includes the wiring from DB to Computer point.)
20 A x 250 V plug & socket with interlocked switched socket, DP MCB and surface mounting box IP 66 with DIN rail for 2 module legrand make Cat no.056669 or equivalent but without cost of wiring and piping.
METAL CLAD SWITCJH SOCKET SITC of Metal Clad Switch Socket with 10A SP MCB (2P+E)
SITC of Metal Clad Switch Socket with 20A DP MCB (2P+E)
SITC of Metal Clad Switch Socket with 20A FP ELMCB (2P+E)
SITC of Metal Clad Switch Socket with 32A FP ELMCB (P+E)
MAINS The mains is considered from the meter/sub panel to the individual distribution boards. Supplying and Laying mains with 4 nos. of 25 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 2 nos 10 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 50 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Laying mains with 4 nos. of 16 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 2 nos 6 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Providing mains with 4 nos. of 10 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 2 nos 4 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Providing mains with 4 nos. of 6 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 2 nos 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Laying mains with 2 nos. of 4 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories.
Supplying and Laying mains with 2 nos. of 6 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories.
Supplying and Providing mains with 2 nos. of 10 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 nos 6.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Laying mains with 2 nos. of 2.5 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories.
Supplying and Laying mains with 2 nos. of 1.5 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 1.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories.
Supplying , fabricating and installation of various sizes junction boxes made out to 14 gauge sheet with all necessary accessories & hardware etc All the necessary fabrication required will be included in the scope of contractor. Scope also includes two coat of primer and two coat of paining of each items on all the sides complete in all respect.
ELW 11.00Light Fixtures and Fans Supplying and erecting, testing and commissioning of 21W 4' Feet LED Recessed Mounted indoor Channel Linear Lights Fittings with opal diffuser-Make equilavent Regent make Slash s (Minimum 2200 Lumens)
Supplying and erecting, testing and commissioning of 42W 7'/8' Feet LED Recessed Mounted indoor Channel Linear Lights Fittings with opal diffuser-Make equilavent Regent make Slash s (Minimum 4200 Lumens)
Supplying and erecting, testing and commissioning of 21W 4' Feet LED Surface/Suspended Mounted indoor Channel Linear Lights Fittings with opal diffuser-Make equilavent Regent make Slash S, complete with all hanging & mounting accessories.(Minimum 2400 Lumens)
Supplying and erecting, testing and commissioning of 42W 7'/8' Feet LED Hanging Mounted indoor Channel Linear Lights Fittings with opal diffuser-Make equilavent Regent make Slash S, complete with all hanging & mounting accessories.(Minimum 4200 Lumens)
Supplying and erecting, testing and commissioning of 60W 7'/8' Feet LED Recessed Mounted indoor Channel Linear Lights Fittings with opal diffuser-Make equilavent Regent make Slash S, complete with all hanging & mounting accessories
Supplying and erecting, testing and commissioning of 36W LED Recessed Mounted Square (600 x600 mm.) indoor Panel type -Make Philips RC380 LED42S or equilavent (Minimum 4200 Lumens)
Supplying and erecting, testing and commissioning of 50W LED Recessed Mounted Square indoor Panel with opal diffuser-Make Philips RC380 LED72S or equilavent (Minimum 7200 Lumens)
Supplying and erecting, testing and commissioning of 20W 4 ' LED Surface Mounted indoor Battern Lights Fittings - Philips or equilavent (BN100C LED20S) For Single lamp.
Supplying and erecting, testing and commissioning of 40W 4 ' LED Surface Mounted indoor Battern Lights Fittings - Philips or equilavent (BN100C LED40S) For Double lamp.
Supplying and erecting, testing and commissioning of LED Surface Mounted Down Lighter 22W LED - Philips Make SM251 LED22S.
Supplying and erecting, testing and commissioning of LED Surface Mounted Down Lighter 18W LED - Philips Make SM251 LED20S.
Supplying and erecting, testing and commissioning of LED Surface Mounted Down Lighter 12w LED - Philips Make SM251 LED12S.
Supplying and erecting, testing and commissioning of 26W LED Surface Mounted Down Lighter -Make Wipro or equilavent ( Halo,CRDL-11S033HP57)
Supplying and erecting, testing and commissioning of 650mm dia LED Hanging Light Point Type Vela Round 1250 direct/indirect -Regent Make Solo 45W or equivivalent.
Supplying and erecting, testing and commissioning of LED Recessed Mounted Circular with High Efficency Translucence Diffuser -Make Regent or equilavent (Type-Solo LED 55 KW With Dimmble)
Supplying and erecting, testing and commissioning of Wall Mounted LED Black Light -Crompton or equilavent (Type-STUD-LBHP-10-CDL)
Supplying and erecting, testing and commissioning of LED Surface Mounted Down Lighter -Make Regent Rea IP65-35w or equivivalent ( EXTERIOR-IP65)
Supplying and erecting, testing and commissioning of LED Surface Mounted Industrail Corroson proof Fixture Ip 65 -Make Crompton or or equilavent (IPFC111LT8-16 1X 20W)
Supplying and erecting, testing and commissioning of LED Surface Mounted Industrail Corroson proof Fixture Ip 65 -Make Crompton or or equilavent (IPFC111LT8-16 2X 20W)
Supplying and erecting, testing and commissioning of 5W Foot Light Point Outdoor Duty IP 67
Supplying and erecting, testing and commissioning Hanging Light Point -Phillips or equilavent (Type -QPG 303) (Lamp -120to 14w led e27)
Supplying and erecting, testing and commissioning (F) 12W LED Under Water Light,12V DC including Driver,IP-67 with die-cast/deep drawn housing with impact resistance clear toughened glass.
Supply,Installation, testing and commissioning following sizes ceiling Fans with 5 step electronic regulator. 36" Dia Sweep Ceiling Fan as per approved colour & equivalent to crompton make high speed Providing and erecting Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 230 V. 50 Cys. 1200 mm. sweep complete, canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2, 3 core flexible wire with earthing [ Make shall be approved by Engineer in charge]
Supplying and erecting 19/20mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/O. 2 flat 3 core flexible wire with ear thing.
Supplying and erecting approved make low noise decorative exhaust fan having size 200mm with 1350 RPM with square frame.ABS body with inbuilt lowers & square frame.
Supplying and erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM. (A)305 mm dai 900 RPM (CAT-2)
(B)380 mm dai 900 RPM (CAT-2)
(C)380 mm dai 1400 RPM (CAT-2)
(D)450 mm dai 900 RPM (CAT-2)
(E)450 mm dai 1400 RPM (CAT-2)
SITC of suitable M.S. louver shutter of the Exhaust fan.
Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover.(approved make OEM has to submit test certificate including value of earth resistane of installation. -Length of Pipe : 3 Mtrs. -Back filling Compound :2 nos Bags of 25 Kg
Earth wire/strips : Supply and laying cu. earthing required size strips for interconnecting the earthing stations, panels, DB's etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with : a) Fixing accessories. b) Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. 25 x 3 mm/ 32X6mm / 50x6mm CU. strip/ 38x6 Cu earth link
SITC of No.8 gauge bare cu. earth wire
ELW 13.00 Miscellaneous PVC PIPES Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 25 mm dia with GI pulling wire.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 32 mm dia with GI pulling wire.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 40 mm dia.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 50 mm dia.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 75 mm dia.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 90 mm dia.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 110 mm dia.
Supplying and laying following sizes DWC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 200 mm inner dia.
Supplying and laying following sizes DWC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 63 mm Outer dia.
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes. 25mm
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes. 32mm
SITC of of 3 compatement 225 mm x 38 mm, 1.6mm thick, under floor metal trunking/race way with all accessories made out of hot dip pre galvanized metal coated steel sheet.
SITC of of 1 compartement 100 mm x 38 mm, 1.6 mm thick, under floor metal trunking/race way with all accessories made out of hot dip pre galvanized metal coated steel sheet.
SITC of 3 compartment Access outlet / service box of 250 x 250 x 60-75 mm with all accessories made out of high pressure die cast material suitable for above race ways .
SITC of 2 compatement 100 mm x 50 mm wall trunking/race way with cover and all accessories made out of PVC .
Fire Stopper SITC of Equivalent to Hilti make Hilti Mineral Wool Board System Providing Fire resistant board system with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The fire resistant board system shall comprise of a mineral wool board coated with an ablative coating CP 670 at 0.7mm dft. The mineral wool board should be of min.160 kg/m3 density. All contact surfaces and cavities shall be sealed with a joint filler CP 606. The service lines could be of various types like electrical cables trays, metal pipes, etc. The product shall be age tested for as per Dafstb and DIBT standards. The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 38 g/l as per LEED 2009. The product shall bear the UL and FM approval logo on the packing where applicable.
SITC of Equivalent to Hilti make CP 636 Firestop Mortar Providing & fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc. The product shall be age tested as per Dafstb and DIBT standards. The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.
SITC of Equivalent to Hilti make CP 620 Expanding Seal Providing Fire expanding foam with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls made of concrete/ masonry or Gypsum for passing service shafts. The expanding foam expands seven times its volume to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The product shall be age tested as per Dafstb and DIBT standards. The product shall provide water tightness when tested for W rating as per UL standards and shall be tested for providing a sound insualtion of 50 db when tested in accordance with ASTM E 90. The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 1.3 g/l as per LEED 2009. The product shall be tested and approved by third party agencies such as UL & FM. The product should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.
ELW 14.00 External Lighiting Poles Supply & installation of 3.6 Mtr long, 114 mm outer uniform dia. GI street light pole with medium class GI pipe with zinc coating and two coats of paint / pu coats of approved shed complete with base plate as per requirement complete in all respect as per drawing. Junction box shall be in concealed manner (inside the pole)with one no 6A SP mcb and 5 way 16A Connector strip suitable to terminate armoured cables with glands. Adequate size cutout with opeanable hinged door should be provided on pole with necessary gasket to ensure water tight arrangement for pulling cables and installation of mcb, connectors etc, complete in all respect as per requirement and instruction of engineer in charge.Scope also includes necessary foundation, earthing, cable entry pipes, 3 core round flexible wire from junction box to light fixture etc,.
Supply & installation of 6 Mtr long, 165 mm outer uniform dia. GI street light pole with medium class GI pipe with zinc coating and two coats of paint / pu coats of approved shed complete with base plate as per requirement complete in all respect as per drawing. with double arm bracket & Junction box shall be in concealed manner (inside the pole)with one no 6A SP mcb and 5 way 16A Connector strip suitable to terminate armoured cables with glands. Adequate size cutout with opeanable hinged door should be provided on pole with necessary gasket to ensure water tight arrangement for pulling cables and installation of mcb, connectors etc, complete in all respect as per requirement and instruction of engineer in charge.Scope also includes necessary foundation, earthing, cable entry pipes, 3 core round flexible wire from junction box to light fixture etc,.
Supply & installation of 4.6 Mtr long, 165 mm outer uniform dia. GI street light pole with medium class GI pipe with zinc coating and two coats of paint / pu coats of approved shed complete with base plate as per requirement complete in all respect as per drawing. with double arm bracket & Junction box shall be in concealed manner (inside the pole)with one no 6A SP mcb and 5 way 16A Connector strip suitable to terminate armoured cables with glands. Adequate size cutout with opeanable hinged door should be provided on pole with necessary gasket to ensure water tight arrangement for pulling cables and installation of mcb, connectors etc, complete in all respect as per requirement and instruction of engineer in charge.Scope also includes necessary foundation, earthing, cable entry pipes, 3 core round flexible wire from junction box to light fixture etc,.
STREET LIGHT FIXTURE Supplying, erecting, connecting, testing and commissioning of following type posttop Light Fixture with all necessary Hadware, Internal Wiring with Lamp,Ballast etc. all required accessories Complete in all respect. Posttop Light fixture-Keselec VALE 50W LED ASYM 3000K DECORETIVE Posttop IP 66 OPTIC LUMINAIRE WITH ALUMINIUM BODY CLEAR ACCYLIC
Supplying, erecting, connecting, testing and commissioning of following type street Light Fixture with all necessary Hadware, Internal Wiring with Lamp,Ballast etc. all required accessories Complete in all respect. Keselec VALE 50W LED ASYM 3000K DECORETIVE Suspended IP 66 OPTIC LUMINAIRE WITH ALUMINIUM BODY CLEAR ACCYLIC
Supplying, erecting, connecting, testing and commissioning of following type street Light Fixture with all necessary Hadware, Internal Wiring with Lamp,Ballast etc. all required accessories Complete in all respect. Keselec VALE 50W LED ASYM 3000K DECORETIVE Suspended IP 66 OPTIC LUMINAIRE WITH ALUMINIUM BODY CLEAR ACCYLIC
Supplying, erecting, connecting, testing and commissioning of 1000 mm.height , 18W and above Bollard with all necessary Hadware, Internal Wiring with Lamp,Ballast etc. all required accessories Complete in all respect with base plate & foudation bolts Bollard -Make - Ligman or equivalent LED lamp, Integral Ballast, IP65
ELW Sec 15.00 Lighitning Protection SITC of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per IEC 62561- 2 conducted in the Govt. accredited thirty party laboratory to meet the requirement of IS/IEC 62305 with Required Accessories - Aluminium Holding clamp at every 1 mtr distance, Aluminium/SS cross splicer at every crossing of Alu. conductor, Expansion piece with connectors at every 20 mtr distance, Aluminium straight Splicer to connect conductors. All Accessories should be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse current withstand test: 100 kA of 10/350µs waveform(Ageing & Electrical test ) conducted in a sequence manner & tested in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 6230
Supply, installation, testing and commissioning of test link complete with inter connections between aluminium round conductor & GI strip or GI strip to GI strip all fixing accessories etc required for complete installation, Complete in all respect with all required accessories.
SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST 34mm dia 3000 mm long- Cold Galvanized
Down Conductor System SITC of 10 mm MS Round Solid Conductor having smooth surface Should be tested and use exclusively for lightning protection (Vertical Riser/Down Conductor which shall be concealed in Column) to meet the requirement of IS IEC 62305 With Accessories - Earthing stud of dimension SS-75mm OD plate with 10mm dia tail connector used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. (For Interconnecting the Column and the Terrace AL Conductor / Strip/Flat), SS Cross Connector to connect Earth fixing point to vertical raiser/Down conductor, SS Straight Splicer at every 4 Mtr to connect MS conductor in column, Bonding /Rebar Clamp at every 3 mtr suitable for interconnecting round conductor with reinforcement inside the concrete for structural earthing system, SS connector -To connect external conductor 8- 10 mm with earth fixing point. All Accessories should be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse current withstand test: 100 kA of 10/350µs waveform(Ageing & Electrical test ) conducted in a sequence manner & tested in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 6230
SITC of Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Complete in all respect with all required accessories.
ELW 16.00 UPS Supply (FOR Site), Testing & Commissioning of ON LINE UPS system with 15 mins battery backup and with battery rack complete in all respect. 40KVA UPS 3 ph in 3 ph out for balance load
Supplying and erecting approved make online Un-interruptible Power Supply system with IGBT Based rectifer and Inverter & sealed maintenance free batteries. Single phase Input and Single Phase output with Inbuilt Isolation transformer with 0.8 load power factor with battery, over under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following capacity & with Following size of batteries for 30 Min Backup (Minimum 6720 VAh) 6 KVA UPS with 28 AH, 20 Nos. Battery Certification : BIS
ELW 17.00 SOLAR SYSTEM SOLAR PLANT Design, Engineering, Supply, Installation, Testing & Commissioning of 100 KWp Grid connected Solar PV Power Plant consisting of Solar PV modules, Power Conditioning Unit (Inverter with all accessories/ features), Junction Boxes, PVC Pipes, Cables/Wires including connectors/plugs/fuses, ACDB, Suitable Lightening Arrestor/Earthlink etc. and accessories along with Tool kit and spares for 1 year. The scope of work includes suitable mounting along with all cables, hardware, nuts, bolts etc.
ELV WORKS Sec.1.0 Telephone and Data Networking Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed. 25 mm
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (A)50 mm outer dia
Providing & erecting main Distribution (MDF) indoor type, back mounted frame as per DoT standard approved with krone strips (e) Suitable for 200 pair
Cabling - Multipair Cables Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos. of pairs. With necessary connections. A Conductor Size 0.5 mm. (b) Armoured. (Jelly Filled) (3) Fifty Pairs.
Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos. of pairs. With necessary connections. A Conductor Size 0.5 mm. (b) Armoured. (Jelly Filled) (4) One Hundred Pairs.
Telephone / Data Networking Cabling Supplying & erecting approved make LAN cable of following size in existing pipe as per direction. [C] CAT - 6
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge. (8) Computer RJ-45 socket Cat. III.
SITC of Jack Panel, fully loaded with 24 nos. UTP ports for PCB based IO Jacks (RJ45, TIA-568C Category-6, Installation and Termination of all 24 nos. Catergory-6 UTP , unloaded with individually replaceable 24 nos. Category-6 I/O Jacks complying with TIA-568.C.2, as per given jack specification Shall be suitable for loading unshielded & shielded jacks for different category systems (CAT 6 & CAT 6A)
SITC of company fabricated patch cords shall conform to Cat- 6 & conductor shall be stranded for better flexibility Shall support network line speeds up to 1 Gbps Shall have RJ-45 jacks. (A) 1 Mtr
SITC of company fabricated patch cords shall conform to Cat- 6 & conductor shall be stranded for better flexibility Shall support network line speeds up to 1 Gbps Shall have RJ-45 jacks. (B) 2 Mtr
Data Networking - Fiber Optic Cable and Components Providing & erecting Optical Fiber cable should be ISO/IEC- 11801 , Outer sheath FRLSZH Shall be 9µ, Single mode OS2 steel armoured cable as per ISO/IEC- 11801 Shall be able to meet Gigabit & 10 Gigabit Ethernet performance requirement specified by IEEE 802.3z (1000 Base-X) & IEEE 802.3ae (10GBase-X) Shall have water blocked construction to prevent water absorption and consequent damages. Water blocking with flooding Gel and water blocking yarn shall comply for IEC 60332-3 for flame retardant, IEC 61034- 2 for low smoke & IEC 60754-2 for toxicity & acidity. Tensile load should be 2700 Newton or higher Optical Parameters – SM, (a) Attenuation @ 1310nm(max) ≤ 0.34 dB/Km, (b) Attenuation @ 1550nm(max) ≤ 0.22 dB/Km with neccessory connections as per technical specification etc. as required. (A) 6 core Single mode
Providing & erecting Optical Fiber cable should be ISO/IEC- 11801 , Outer sheath FRLSZH Shall be 9µ, Single mode OS2 steel armoured cable as per ISO/IEC- 11801 Shall be able to meet Gigabit & 10 Gigabit Ethernet performance requirement specified by IEEE 802.3z (1000 Base-X) & IEEE 802.3ae (10GBase-X) Shall have water blocked construction to prevent water absorption and consequent damages. Water blocking with flooding Gel and water blocking yarn shall comply for IEC 60332-3 for flame retardant, IEC 61034- 2 for low smoke & IEC 60754-2 for toxicity & acidity. Tensile load should be 2700 Newton or higher Optical Parameters – SM, (a) Attenuation @ 1310nm(max) ≤ 0.34 dB/Km, (b) Attenuation @ 1550nm(max) ≤ 0.22 dB/Km with neccessory connections as per technical specification etc. as required. (C) 24 core Single mode
Providing & erecting Fiber Optic LC style fully loaded Patch Panel (FOPP), 19" Rack Mount with following nos. of OS2 9/125μ Pigtails as per ISO/IEC-11801-OS2 Pigtails with LC Type Connectors Shall have all accessories including coupler plates pre loaded with duplex LC couplers (OS2), pigtails for terminating fibers on the FOPP Pigtail Attenuation ≤0.3dB measured measured against reference connector Return Loss ≥ 45dB, in mated condition Pigtail Cable Information – Outer Jacket Diamter – 0.9mm, Outer jacket colour – white , Outer Jacket Material – LSZH Shall be Front Patching Type, 1U high and rack mountable on standard 19” rack with mounting arrangements (B) 24F Loaded with Coupler, Pigtail and Splice Trays
Providing & erecting Fiber Optic LC style fully loaded Patch Panel (FOPP), 19" Rack Mount with following nos. of OS2 9/125μ Pigtails as per ISO/IEC-11801-OS2 Pigtails with LC Type Connectors Shall have all accessories including coupler plates pre loaded with duplex LC couplers (OS2), pigtails for terminating fibers on the FOPP Pigtail Attenuation ≤0.3dB measured measured against reference connector Return Loss ≥ 45dB, in mated condition Pigtail Cable Information – Outer Jacket Diamter – 0.9mm, Outer jacket colour – white , Outer Jacket Material – LSZH Shall be Front Patching Type, 1U high and rack mountable on standard 19” rack with mounting arrangements (A) 12F Loaded with Coupler, Pigtail and Splice Trays
SITC of PIGTAIL LC SM SIMPLEX LENGTH- 1m as per technical specification etc. as required.
SITC of PATCH CORD LC-LC SM DUPLEX LENGTH- 3m as per technical specification etc. as required.
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. for OFC Marker, as per technical specification etc. as required.
Networking Enclosures & Accessories Supplying, installtion, testing and commissioning of ruggedized, IP54 rated outdoor Pole/Wall mountable 9U enclosure for housing power supplies, fiber LIUs, and industrial networking switch, with suitable provisions for DIN rails, cable management as per technical specification etc. as required.
Providing & Erecting Netwrok rack with following capacity with Necessary cooling fan,Cable manager,6A PDU,equipment rack with necessary mounting accessories. (D) 15 U
Providing & Erecting Netwrok rack with following capacity with Necessary cooling fan,Cable manager,6A PDU,equipment rack with necessary mounting accessories. (H) 24 U
Supply, Installation, Testing & Commissioning of 42U (800W X 800D) floor mount closed rack complied with UL, CSA, TUV, EIA 310, DIN 41494, DIN 41494, ISO 9001, ISO 14001, IEC 297 and current industry practices, CRCA Steel Door - Plain, Vented at Bottom, Fully perforated at front and rear side, with screw fitted side panels. 19" L type mounting angles at front and rear, top and bottom cover with cable entry provision, with required accessories as per technical specification etc. as required.
Active Components- Data & Voice Networking TYPE-1 Core Switch Supplying, installtion, testing and commissioning of Layer 3 features switch: 16 # port 10G SFP+ & 8 Port 10G Copper Ports With redudant power supply & standard mouting hardware & accessories. Core Switch for Server room complete as per technical specification etc. as required.
Type 2 Switch: 24 Port POE Supplying, installation, testing and commissioning of Layer 2 Manageable, Stackable Networking switch having 24 # 10/100/1000Tx ports, all 24 ports shall be capable of providing PoE+ as per 802.3at, switch having a PoE power budget of minimum 370 Watts, minimum 4 SFP+ ports complete as per technical specification etc. as required.
Type 3 Switch: 24 Port Non POE Supplying, installation, testing and commissioning of Layer 2 manageable networking switch, 24 # 10/100/1000Tx ports,minimum 4 SFP+ ports complete as per technical specification etc. as required.
Type 4 Switch: 48 Port POE Switch Supply, Installation, Testing and Commissioning of Layer 2 Manageable, Stackable Networking switch having 48 nos. 10/100/1000 Base-T ports, all ports capable of providing PoE+ as per 802.3at, switch having a PoE power budget of minimum 720 Watts, additional minimum 4 SFP+ ports complete as per technical specification etc. as required.
Type 5 Switch: 48 Port Non - POE Supply, Installation, Testing and Commissioning of Networking Switch (Access Switch) having 48 nos. 10/100/1000 Base-T ports, stacking, additional minimum 4 SFP+ ports, with all licenses from day 1 and inclusive of dual redundant hot-swappable power supplies installed from day 1, complete as required and as per technical specifications
TYPE-6 Supplying, installtion, testing and commissioning of Industrial Grade Layer 2 Fully Managed 8 Ports Gigabit Switches, 8 x Gigabit RJ-45 PoE / PoE+ ports, 2 x 1G SFP ports, -40° to 70° C operating temperature, Up to 30W per port PoE Budget (PoE modules only) as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of 10G SFP+ LR singlemode transceivers, 1310nm, duplex LC termination supporting distance upto 10000 mtrs, inclusive of any hardware or interfaces such as modules for populating SM-LC transceivers complete as required.
Supply, Installation, Testing and Commissioning of 1G Base-T transceivers, RJ-45 termination supporting distance upto 100 mtrs, inclusive of any hardware or interfaces such as modules for populating RJ-45 Base-T transceivers complete as required.
Supply, Installation, Testing and Commissioning of Wireless indoor Access Point supporting Dual band with Wi-Fi 6 operation with MIMO support 4 x 4, Minimum 3 streams, One 10/100/1000 BASE-TX auto-sensing (RJ45) PoE port, as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Wireless Controller & WIPS : Wireless controller alongwith WIPS capable of supporting min. 400 access points, inclusive of licence costs for supplied Access Points from day-1. Centralized Hardware Controller based architecture, complete as required and as per technical specifications
Network Management System Supply, Installation, Testing and Commissioning of Network Management System (NMS): Network Management Tool for Centralised Configuration, Administration, Fault and Performance Monitoring and Virtualisation Management for wired and wireless LAN infrastructure complete as required and as per technical specifications.
SITC of Digital / PCM / TDM EPABX System having SMT design, system with flexible universal slots. Inbuilt Auto attendant facility, Minimum 15 Nos. conference, Analog extension line, Calling GSM, E&M line, PRI / EI & VOIP program me through Analog telephone digital key from Ethernet, public address cord, shall have unrestricted simultaneous dialing facility, QSIG protocol on PRI, 95 / STD / ISD / Local-Locking, Class of Service, Quick Dial-Single Digit dialing of any two external number, Once only ring device, Boss/Secretary-Do not disturb Facility, Power Down Mode, Hot Line, Hot Outward Dialing, Day Night Mode, Auto Call Back, Barge-in, Call Pick Up & Call Transfer, Call transfer while Ringing with Voice Guide System, (DISA), Caller ID (CLI), CLI Base ECF, CLI Base routing Internet Ready Port, External Music Port, Call Budgeting, Call Most Calculation (ASMDR), DID Direct Inverse Dialing, External Music Input, Fax Homing, Global Directory Printing with following capacities [E] No of Extension 128, No of Junctions 24, No of expandable ports : 512, Operators Console - 01 Compatible : ISDN and Networking
providing and erecting add on Digital PRI T1E1 single card suitable for existing system of following ports suitable for 30 channel as per technical specification etc. as required.
Providing and erecting IP Phone with display with all IP system supported
Supply, Installation, Testing and Commissioning of User Call Control Application for all users/extensions, Voice Messaging Application inclusive of voice mail licences for users and inclusive of computer application and operating system, Emergency response services with voice messaging, inclusive of licences as per technical Specification.
Supply, Installation,Testing and Commissioning of Digital Telephone with DSS console and related software/ licences as per tender specification etc. as required.
Sec.2.0 Video Survelance/CCTV System Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Camera, 1/2.8" CMOS, 2 MP @ 25fps, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 X 1080, triple stream, 2.8 -12 mm motorized focus and zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 50m IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 2 In/ 1out, PoE, H.264 High Profile and MJPEG, Inbuilt analytics Trigger line/Intrusion/Loitering, PoE Class 3 and 12V DC, IP 67, IK 10 vandal proof, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Bullet Camera, 1/2.8" CMOS, 2 MP @ 25fps, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 X 1080, triple stream, 2.8 -12 mm motorized focus and zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 50m IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 2 In/ 1out, PoE, H.264 High Profile and MJPEG, Inbuilt analytics Trigger line/Intrusion/Loitering, PoE Class 3 and 12V DC, IP 67, IK 10 vandal proof, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR PTZ Camera with auto tracking, 1/1.9" CMOS, 2 MP @ 25fps, triple stream, Min. Illumination required 0.005 lux @ F1.6 (color) & 0.0005 lux @ F 1.6(B/W), 120dB True WDR, Min. Pixels 1920 × 1080, triple stream, 6mm –180 mm 30x motorized focus & zoom lens, BLC, HLC, 3DNR, Defog, Electronic Image Stabilitzation, Privacy Mask, IR range with 150mtr IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 7 In/ 2 out, PoE, H.264 High Profile and MJPEG, PoE Class 5 and 12V DC/24VAC, IP 67, IK 10 vandal proof, Having Operating temp range : –40°C to 70° C. Certifications: ONVIF Profile S compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant. as per technical specification etc. as required.
Supplying, installtion, testing and commissioning of Video Management Software supporting ONVIF Profile S & G, PSIA, real time streaming protocol (RTSP) standards, emerging technologies in the industry, like 4K resolution, H.265 video compression codec, 3D PTZ control, Fisheye camera and multi-imager/ lens camera support, and intelligence events. Software proposed shall have scalability of 128 cameras per server with at least 256 licenses to record all the cameras from the Day 1 and expandable up to unlimited cameras. Videom Managment Software shall support simultaneous recording, live monitoring, playback/search of recorded video for up to 4K resolution on all cameras, taking snapshots and viewing presets for PTZ cameras and system management, Videowall management. Video Management Software shall support - 1) Free Firmware upgrade; 2) Lifetime software licence, must not be renewed periodically; 3) It should support unlimited channels; 4) It should support N:1 and N:M redundancy; 5) It should have calender view for better playback investigation; 6) It should support Smart Motion Detection; 7) It Should support Surrounding View feature of cameras; 8) The camera zoom in/out, controlling and setting should be able done from software; 9) The proposed softsware should be latest versin available from OEM 10) VMS Shall support scheduled backfilling of the recordings from the edge storage/SD card of cameras to the server. For details specification refer tender technical specification etc. as required.
Supplying, installtion, testing and commissioning of Server(s) required for NSM & NVMMS - Industry standard Intel based platform, rack mounted, redundancy architecture for critical hardware components, licensed Microsoft Server operating system and requisite user licenses, licensed application suites, 2 x Quad Core Intel® Xeon latest processors or better, 8 GB of RAM, 2 x 1.2 TB of SAS HDDs, minimum 2 additional hard disk drive bays for expansion, 1,280 x 1,024 Display/ video resolution, 2 X 10/100/1000 ethernet network interface card, Video memory 2GB above, RAID support built-in, DirectX 8.1 above and pre-installed DVD-R/W Drive and Appropriate Licensed Operating Systems as per NSM & NVMMS Requirement. as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Network storage required with a capacity to store the content for 288 cameras for 24Hrs x 30 days at 25fps and 1080p (Minimum 350TB from day 1). It should be scalable (should have sufficient expansion bays for HDDs) for at least additional 50 cameras. Vendor shall submit bandwidth and storage calculator for the proposed camera models, as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Client PC - Industry standard Intel based platform computer system. Intel Core i7 latest generation, 4 GB of RAM DDR3 ,1 TB SATA II hard drive for OS and VMS applications, NVidia card 1 GB graphics card , 1600 x 1200 or higher screen resolution, 1 X 1000Mbps ethernet network interface card ,16x DVD+/- RW Drive alongwith appropriate licenced Operating System, licenced applications suites from OEM and application licences as per the technical specifications etc. as required.
Supplying, installing, testing and commissioning of 65-inch, LED Panel, 16:9 Aspect ratio, 350 cd/m2 Brightness, Anti-glare panel surface with viewing angle 176 degree, 4K pixels resolution, Video Input Interfaces : HDMI Type A Connector x 2, Mini D-sub 15-pin x 1, 20 Watt Built in Speakers with wall mount bracket as per technical specification etc. as required.
Supply installation testing and commissioning of 116" Diagonal, 3.69 Sqm2 Videowall with controller, 1.25 Pixel pitch as per technical specification etc. as required.
Supplying, installation, testing & commissioning of central graphical fire alarm management system having IS or BS (EN 54) (Vds approved) or NFPA 72 UL/ULC/FM approved) with Latest Ammendment to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of repeater panel having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector having IS-11360-1985 or BS 5446 Part I-1977 & Part VII –1985 (VdS approved) or NFPA72 ( UL/ULC/FM approved) with Latest ammendment complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
SITC of Sensor common mounting base, includes stainless steel contacts, slim profile - only 8mm, quick connection via square cable clamps, facility for remote indicator, Approved by LPCB. as per technical specification etc. as required.
SITC of Sensor isolator mounting base, includes stainless steel contacts, slim profile - only 8mm, quick connection via square cable clamps, facility for remote indicator, Approved by LPCB. as per technical specification etc. as required.
Supplying, installation, testing & commissioning of intelligent aspiration detector having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment for area coverage of minimum 5000 sq. ft. complete as required.
SITC of Analogue Addressable Single Output Module . which Includes a single output, flying leads for easy installation. Electronically addressed, Approved by LPCB & Vds. as per technical specification etc. as required.
SITC of Analogue Addressable Single Input Module. which Includes a single monitored input, flying leads for easy installation. Electronically addressed, Approved by LPCB & Vds. as per technical specification etc. as required.
SITC of Duct Detector with 0.6 Mtr Unique sampling Tube. as per technical specification etc. as required.
Digital Evac / Public Address System. SITC of Controller Heart of the Plena Voice Alarm System EN 54‑16 certified Built-in message manager and 240 W amplifier Six‑zone outputs 6 emergency and 6 business triggers as per technical specification etc. as required.
SITC of Power amplifier, 480W as per technical specification etc. as required.
SITC of Ceiling loudspeaker 6W, metal with clamp and back box as per technical specification etc. as required.
SITC of Cabinet loudspeaker 6W as per technical specification etc. as required.
SITC of Music source, USB/SD/Tuner MP3 playback from SD card and USB inputs FM tuner with RDS, presets and digital control Simultaneous operation of SD/USB-player and FM tuner Separate outputs for digital source and FM tuner
SITC of Volume control unit, 36W as per technical specification etc. as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. (A)Speaker cable Single pair, 2-core, 1.5 sqmm
Sec.4.0 Access Control System “Providing & erecting approved make Fingerprint and card based premium Door controller with LCD and Keypad having following features.”(A) Optical Fingerprint and card based Reader (Card personality Module not included) “(B) Dot – Matrix LCD and Touch sense Keypad “(C) Built-in interfaces like door lock, door sense exit Reader, Exit switch, Ethernet RS485, Aux Input & aux output port “(D) 5000 Events, access Control, Time Attendance, Tamper Detection “(E) 4 LEDS and Buzzer”
“Providing & erecting approved make Card Reader having following features. “[A] Wiegand/ RS232 Interface “(B) Power supply from COSEC Door controller or through Separate Adaptor “(C) Compatible with any COSEC Door controllers “(D) 4 LEDs (Status, Alarm, Allowed and Denied) and Buzzer “(E) Tamper Detection”
“Providing & erecting approved make Card Personality Module (CPM) having following features “(A) EM proximity Card Reader Module [Low Frequency] “(B) Compatible with any COSEC Door Controllers and COSEC Reader CA “(C) Supports EM Proximity Card”
Providing & erecting approved make Application Software Platform for 500 User having following features “(A) With 100 Users “ (B) Expandable up to 500 Users with COSEC USER 100 “(C) Supports up to 16 Door Controller “(D) Basic Access Control Basic Time Attendance and Enrollment Management (E) Compatible with all COSEC Hardware “(F) Add Other COSEC software modules on requirement.
Providing & erecting approved make Time Attendance Module (TAM) Having following features “(A) Comprehensive Time Attendance and Leave Management Software Module “(B) For 500 Users [AS per COSEC GE PLATFORM USERS] “(C) Attendance and leave Policy Creation “(D) Integration with payroll and HRM “(E) Shift Schedule, Holiday Schedule and Past Adjustment “(F) Manually Attendance Correction “(G) Leave/Tour Application and approval “(H) Report and Charts Generation
“Providing & erecting approved make Access control Module (ACM) having following features (A) Comprehensive Access Control Management (B) For 500 Users [AS PER COSEC GE PLATFORM users] (C) Time, User and Zone Based Access Control (D) Access Zones, Access Modes and Access Levels (E) Advanced Access Control Feature like 2-person rule, First in user rule, Antipass Back, Guard Tour, Duress Detection and more (F) Various Reports Generation
Supply, Installation, Testing & Commissioning of Drop Bolt Or EM Door Lock as per Door type & site Location requirement.
Sec.5.0 Cable TV Distribution System Providing following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate front plate modules erected with necessary connection. As desired by Engineer In charge. (4) TV Co-axial Socket outlet. Cat. III.
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (b) RG – 6.
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (e) RG – 11.
Sec.5.0 Audio Visual System Supply, Installation, Testing and Commissioning of 75" Smart Interactive 4K display, 7H hardness toughen anti glared glass , In-built Android 8.0, RAM 3 GB, 16 GB ROM, 10 Points Touch in Android and 20 points Touch in Windows, Smart Object recognition and responsive multi-touch, Multiple Inputs for connectivity, 15W x 2 Speakers, Inbuilt Screen Sharing Software, Slimmer Frame, Customize GUI, Wireless presentation with Quad View Option, Broadcast upto 200 Devices, Remote Display Management with required wall mount kit as per site requirement, as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of Smart Interactive Full HD 55" display |8H Hardness , In built Android, RAM 2 GB,ROM 8 GB, 10 Points InGlass IR Touch, Smart Object recognition and responsive multi-touch, 2 Wide angle Full HD cameras of 86° Field-of-View Lens Integrated in the Panel, 4 Microphones with Pickup Range 8 Mtr having ECHO cancellation Integrated in the Panel, 2 Nos. of 10W Speakers, In-built wifi, BYOD Ready, with required wall mount kit as per site requirement, as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of 85" Smart 4K Non-Touch display , In-built Android 8.0, RAM 3 GB, 16 GB ROM, 20W x 2 Speakers , 6 no. of Beam Forming Microphones with Echo Cancellation, 50000 Hours of Life , 500 nits Brightness, Multiple Inputs for connectivity, Inbuilt Screen Sharing Software, Slimmer Frame |OPS Slot for On-Board Computer Connectivity with required mouting kit as per site requirement, as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of On-Board Computer OPS (Core i5 Processor, 8 GB RAM, 128 GB SSD) with the software as per technical specification etc. as required.
Supplying, installing, testing and commissioning of VC UNIT of Full HD Video Conferencing system with 1 + 3 Sites Connectivity with HD Communication Camera, Boundary Mic X 2 , Two Monitor Output, Video Input : HDMI X 2 for Camera, RGB X 1 and HDMI X 1 for PC Input, Video Output: HDMI X 2, RJ 45 X 1 for Control Purpose as per technical specification etc. as required.
Supplying, installation, testing and commissioning of DLP Laser Projector or better with Laser light source having 20,000 hrs life or more, 9600 Lumens or brighter, WUXGA resolution (1920 x 1200) and Contrast ratio (dynamic) 18,000:1 or better. Inbuilt capability of Vertical & Horizontal Keystone correction, Digital Zoom, 10-bit colour display or better, HDR support, Full HD 3D ready., Inputs: VGA in/out, , 2 HDMI2.0 , HDBaseT, 3G-SDI in/out Controls: 3D sync in/out, RS232, Audio in/out stereo, With Zoom lense of 1.25-2.0:1 zoom, all complete with required mounting kit as per site requirement as per technical specification etc. as required.
SITC of DLP/LCD 5000 Lumens laser projector compatible with 4K & HDR IP6X dust resist provides good brightness and reliability, Up to 30,000 hours laser light source life and virtually zero maintenance for system, 1.6x zoom & vertical lens, Native Resolution WUXGA 1920 x 1200, Brightness, Contrast, 300,000:1 (w/ Extreme black) , Light Source , Laser phosphor Light Source life 30,000 hours to 50% brightness (Eco mode), Zoom Type 1.6x Manual, Lens Shift +8% (99%~107%) vertical, I/O Connectors HDMIx2 (one MHL), USB power(5V/1.5A), VGA-In 1 x1, Composite x1, Audio-In x1 (Mic), Audio-In x1, Audio out x1, VGA Out x1, 12V Out x1, Kensington Lock x1, RS232 x1, RJ45 x1, wireless remote control erected as directed by engineer incharge
SITC of DLP/LCD 4000 Lumens LASER projector compatible with 4K & HDR, IP6X dust resist provides good brightness and reliability, approx 20,000 hours laser light source life and virtually zero maintenance for system, 1.3x zoom, Tilt free orientation, including portrait mode, Native Resolution ,XGS or more Contrast 25,000:1, Light Source Life 20,000 hours to 50% brightness (Eco mode) I/O Connectors HDMI x1, HDMI/MHL x1, VGA in x1, Audio in x 1, Audio out x1, USB Power (5V/1.5A), RS232, Micro USB(FW Upgrade), RJ-45 x1, wireless remote control erected as directed by engineer incharge
SITC of following standard size MW fabric Tab-Tension Tubular Motorized Screen with RF remote, Aspect Ratio-16:9, (G) 160 inch Diagonal
SITC of following standard size MW fabric Tab-Tension Tubular Motorized Screen with RF remote, Aspect Ratio-16:9, (E) 133/135 inch Diagonal
Supplying, installation, testing and commissioning of 297 in diagonal (252" x 157") or higher size matt white motorised projection Screen with required mounting kit as per site requirement, as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Modular Pop-Up Box / Cable cubby Includes a Universal power outlet X 2 Nos. and space for four customer-supplied cables HDMI Port X 1nos, RJ-45 X 2 Nos, as per technical specification etc. as required.
SITC of HDMI TX and give HDBaseT/ twisted pair signal and give HDMI output ,Bi-directional RS-232 and IR signals, resolution of 4K@60 Hz at sampling rate of 4:2:0 ,Minimum data rate of 10Gbps ,HDMI signal over 180m for full HD resolution , 4K resolution upto 90m or above ,HDTV and HDCP compatible ,2K and 4K support ,3D as well as EDID pass through ,Support for Deep Color, x.v.Color™, Lip Sync, HDMI Uncompressed Audio Channels, Dolby TrueHD, DTS −HD, CEC as directed by engineer in charge (B) Premium Make (KRAMER / AMX/ EXTRON / CRESTRON)
SITC of HDMI RX and giveHDBaseT/ twisted pair signal and give HDMI output ,Bi-directional RS-232 and IR signals, resolution of 4K@60 Hz at sampling rate of 4:2:0 ,Minimum data rate of 10Gbps ,HDMI signal over 180m for full HD resolution , 4K resolution upto 90m or above ,HDTV and HDCP compatible ,2K and 4K support ,3D as well as EDID pass through ,Support for Deep Color, x.v.Color™, Lip Sync, HDMI Uncompressed Audio Channels, Dolby TrueHD, DTS −HD, CEC as directed by engineer in charge (B) Premium Make (KRAMER / AMX/ EXTRON / CRESTRON)
Supplying, installation, testing and commissioning of 4K60 HDbaseT Transmitters Should have built in 2x1 switcher, 2xHDMI and 1x HDBaseT output along with 1xHDMI loopout for local monitor or an external switcher should be supplied, as per technical specification etc. as required.
Supplying, installation, testing and commissioning of 8x4 matrix 4K video scalers cum switcher with minimum 6 X HDMI IN, 2 X STP IN and 2 X HDMI Out, 2 X STP Out, HDCP 2.2, EDID supported as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Passive Multiple Driver Column Array EN54, IP65 rated Loudspeaker consisting of 7 x 3.5" full range drivers with 150 W RMS Power @ 8 Ohms, Frequency Response(±3 dB) 150 Hz - 11 kHz, Frequency Range (-10 dB) 110 Hz - 14 kHz, Sensitivity 90 dB, 130 degrees horizontal dispersion, Maximum SPL 112 dB and 118 dB Peak, Transformer Taps at 70V/100V : 150W/ 75W / 37.5W / 19W / 9.5W. EN 54-24 Certified, as per site requirement as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Compact Full Range 4" Ceiling Speaker with 30 W RMS power @ 8 Ohms, Frequency Response (±3 dB) 102Hz - 20kHz, Frequency Range (-10 dB) 70 Hz - 20 kHz, Sensitivity 84 dB, 120 degrees Coverage, Maximum SPL 99 dB Average and 105 dB Peak, Transformer Taps @ 70 V/100V: 25 W / 12.5 W / 6.3 W, UL and EN 54-24:2008 certified Type A with steel back can..as per the technical specifications etc. as required.
Supply, Installation, Testing & Commissioning of Two-way 16 Watt RMS Ceiling loudspeaker suitable for 70/100 V line, 100 Hz - 18 KHz frequency response, SPL Max.100 dB, Sensitivity 87dB (1W @ 1m), Nominal Impedance 8 Ohm.as per the technical specifications etc. as required.
Supply, Installation, Testing & Commissioning of Two-way 16 Watt RMS Wall Surface loudspeaker suitable for 70/100 V line, 100 Hz - 18 KHz frequency response, IP55 rated, SPL Max.100 dB, Sensitivity 87dB, Nominal Impedance 8 Ohm.as per the technical specifications etc. as required.
Supply, Installation, Testing & Commissioning of Dual Channel Commercial Class D Amplifier for Green Room & Control Room with Energy Star Certification delivering 2 x 120 W @ 4/8 Ohms and 70V/100V,distortion <0.05%,Frequency response 20 Hz to 20 kHz, +0.5 / -1 dB,Signal-to-noise >97 dBA, as per site requirement as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of 2-Channel 800W Class D Power Amplifier delivering 2 x 400W per channel at 70 V, 2, 4, 8 and 16 ohms,THD 20 Hz - 20 kHz at 1W <0.1%,Signal to Noise Ratio >112 dBA, Frequency Response 2 Hz - 40 kHz,CMR 50 dB,Sensitivity 4 dBu, as per technical specification etc. as required.
Supplying, installation, testing and commissioning of 4 in 1 Media processor - supports recording, switching, mixing and live streaming at 1080p, Supports 1080p 60/30fps video recording, Supports 4 HDMI Inputs and IP video sources, Should have minimum 1TB inbuilt storage. as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Full HD 1080p, Minimum 20X Optical Zoom, 20 Presets, 30 Frames per Second, Ethernet Out, HDMI Out, 3G-SDI Out, Audio In, RS232/422 Controls, -170° ~ +170° Panning angle, -30° ~ +90° Tilting angle capturing presenter and students. as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Joystick for PAN/Tilt/Zoom Cameras and Focusing, RS232C/RS455 Communication Interfaces, High Brightness OLED Display, Auto Backlit Keys.as per technical specification etc. as required.
SITC of Handheld Wireless Mic with Cardiod polar pattern,Dynamic microphone ,frequency response 80Hz-18kHz,RF sensitivity < 1.0 Uv,Image rejection>55dB,Dyanmic range >95dB and receiver having 30 or more channels possible,S/N ratio >100dB A,dynamic range >95db B,distortion <1 %,frequency band:618-634MHz,more than 12hrs battery life with AA battery.The transmitter & receiver should be of metal body
SITC of Wireless Mic Lapel with condenser,frequency response 100Hz-15kHz,Cardiod polar pattern,,RF sensitivity < 1.0 Uv,Image rejection>55dB,Dyanmic range >95dB and receiver having 32 channels possible,S/N ratio >100dB A,dynamic range >95db B,distortion <1 %,frequency band:618-634MHz,more than 12hrs battery life with AA battery.The transmitter & receiver should be of metal body as per the technical specifications etc. as required.
SITC of Condenser Cardioid 18" Goose neck Microphone for Podium with back electret,with frequency response100 Hz to 15,000 Hz, Cardioid polar pattern,sensitivity of 4.5 mV/Pa and output impedance 200 ohm
Supply, Installation, Testing & Commissioning of UHF Antenna Distribution System, as per the technical specifications etc. as required.
Supply, Installation, Testing & Commissioning of UHF Wide-band Directional LPDA Antennas, as per the technical specifications etc. as required.
Supplying, installing, testing and commissioning of two way communication 10 x 8 Audio Digital Signal Processors, with Minimum 10 AEC balanced mic/line inputs, Minimum eight balanced mic/line outputs. as per technical specification etc. as required.
Supplying, installing, testing and commissioning of Digital Processing Unit with 4 balanced mic inputs, 2 balanced Mic/Line inputs and 1 stereo unbalanced input; 1 stereo and 2 mono outputs; 2-channel USB audio interface, 6-channel Smart Mix (gate or gain sharing), Onboard acoustic echo canceler (AEC) processing, as per technical specification etc. as required.
Supplying, installing, testing and commissioning of Control unit control and power up to 50 delegate units, with monitor loudspeaker, as per technical specification etc. as required.
Supplying, installing, testing and commissioning of Delegate Unit device built in mic, loudspeaker, Minimum Two 3.5 mm stereo headphone sockets, Stem length of the microphone shall be Minimum 19.2 in, as per technical specification etc. as required.
Supplying, installing, testing and commissioning of Chairman Unit device built in mic, loudspeaker, Minimum Two 3.5 mm stereo headphone sockets, with Chairman Priority button, Stem length of the microphone shall be Minimum 19.2 in, as per technical specification etc. as required.
Supplying, installing, testing and commissioning of Extension Cable Assembly - 2MTRS
Supplying, installing, testing and commissioning of Extension Cable Assembly - 10MTRS
Supply, Installation Testing & Commissioning 3 ft HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed Specifications
Supply, Installation Testing & Commissioning 6 ft HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed Specifications
Supply, Installation Testing & Commissioning 12 ft HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed Specifications
Supply, Installation Testing & Commissioning 20 ft HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed Specifications
Supply, Laying, Testing and Commissioning of Ultra Flexible High Speed HDMI Cables HDMI Cable 15 Meter HDMI 2.0 Cable Male to Male, support Deep Color, 4K 4096 x 2160 @60Hz; 3840 x 2160 @ 60Hz 4:4:0, Minimum conductor gauge - 30AWG, gold Plating, as per technical specification etc. as required.
Supply, Laying, Testing and Commissioning of Ultra Flexible High Speed HDMI Cables HDMI Cable 20 Meter HDMI 2.0 Cable Male to Male, support Deep Color, 4K 4096 x 2160 @60Hz; 3840 x 2160 @ 60Hz 4:4:0, Minimum conductor gauge - 30AWG, gold Plating, as per technical specification etc. as required.
Supply, Laying of Shielded Twisted Pair (STP) 4Pairs 24 AWG Cable with connector, as per technical specification etc. as required.
Supply, Laying, Testing and Commissioning of Two 16 AWG conductors non- plenum Speaker Cable, for High performance cable for audio signals as per technical specification etc. as required.
Supply, Laying, Testing and Commissioning of Dual 20 AWG shielded twisted pairs with individual drain wires for Mic and Controlling Purpose, as per technical specification etc. as required.
Sec.6.0 iBMS System Supplying, installation, testing and commissioning of Intel Core I7 Processor with EISA bus and with 3GHz minimum clock speed, minimum of 8 GB RAM , 512 KB cache, Minimum of 1TB storage, optical Mouse, 104 keys key board, with 10/100 Mbps Ethernet card (Min. of 3 slots) & internal modem. Server shall be RAID 5 configured. The system shall be provided with 21" TFT monitor for viewing GUI application. The back up server takes over in case the master server fails. This will be a redundant server configuration. with 21" LED / LCD Colour Monitor. as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Laser Jet B/W Printer - A4 Size. as per technical specification etc. as required.
Supplying, installation, testing and commissioning of IBMS Server Software suite: This Web technology based software suite shall have unlimited concurrent user login licences. The client license provided shall display actual graphics as represented in the server machine. Shall be capable of interfacing with Bacnet/IP based DDC controllers, Bacnet/IP or modbus RTU 3rd party interface. Complete with Webserver for IBMS interface on Internet / Intranet. License for minimum hard/soft I/Os to be considered as per I/O Summary. Software should have the following Key features: 1. User Defined dashboard. Any Number of dashboard can be added by user. 2. Scalar/Vector Graphics to be supported. 3. Monthly Calender Dashboard: Monitor the demand/ consumption pattern for all days in a a month in a single screen. 4. Software shall be able to communicate with bacnet/ lonworks/ modbus simultaneously. 5. Mobile Platform: IPAD/ Android Compatible. 6. Software shall be Forword & Backward Compatible with 10 Years Obselation Support from OEM. 7. Display of HTML 5 Pages fromm company intranet or Internet for full smart device compatibility - with NO Java Dependancy in the Browser. 8.Database supported by software should be either SQL/oracle/db2. Also software should support 128 bit ssl encryption. Note: All required Software with original license competent with BMS software
Supply, Installation, Configuration, Programming of Web Based Energy Management & Reporting Tool software for Monitoring Building efficiency & Customization of Energy Management (For 100 Meters) Application that will Communicate with the Main Framework having Capability of Energy Profiling, Energy Mapping, Load Calculations, Predictive Energy Analysis, Energy Spectrum Analysis etc as per Functional Specifications of the Bid for 50 points. Bidders Must Consider all Application Modules and Licenses to be Part of the Bid. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. for Chiller Units Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for Secondry Pump Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for AHU's (1 Nos) VFD Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for Energy Meter's ( 102 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for UPS's (2 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for Breaker's Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for Fire Alarm System (1500 Points) Soft Data Integration on Bacnet Over IP. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for Access Control System . as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for DGs (2 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for STPs (1 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Chiller Plant Room - as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Air Handling Unit - as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Treated Fresh Air Unit - as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Ventillation Fans - Smoke Exhuast , Evacuation Fans, Jet Fans as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Electrical System - as per technical specification etc. as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Plumbing System - as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Water Tanks - as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Fire Fighting System - as per IO Summary and as per technical specification etc. as required.
Supply, installation, testing and commissioning of hand held portable operator terminals.(POT) touch screen type, shall be able to view graphs , alarms , parameters etc These shall be required if the Controllers and Integration Units do not have a built in keypad on the facia . With required connectors etc. - 4inch. as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Outdoor type Ambient Temperature with Humidity Sensor with radiation shield , IP65 rated(Temp Range -30 to +50 °C, RH : 0-100 %). as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Air Differential Pressure switches the for indicating the Blower status in Air able to measure pressure at zero pascal pressure.as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Air Differential Pressure switches the for indicating the Filter status in Air able to measure pressure at zero pascal pressure.as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Temperature with Humidity Sensor, IP65 rated with RH accuracy 3 %, temp accuracy +_ 0.7 deg (0 to 70 Degree) as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Air Type Differential Pressure Transmitter as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Water Type absolute Pressure Transmitter as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Water Type Differential Pressure Switch as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Immersion Temperature Sensor,IP 65 rated thermister type Range of temp -10 to 110) with Thermowell as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Ultrasonic type Flow Meter as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Ultrasonic type Level Transmitter (5mtr. Depth ) as per technical specification etc. as required.
Supplying, laying , testing and commissioning of 2 Core X 1.0 Sqmm Armoured Shielded Copper Cable (per Hard & Soft I/O points to DDC). as per technical specification etc. as required.
Supplying, laying , testing and commissioning of 4 Core X 1.0 Sqmm Armoured Shielded Copper Cable (per I/O points hard wired to DDC). as per technical specification etc. as required.
Supplying, laying , testing and commissioning of 3 Core X 1.5 Sqmm Armoured Shielded Copper Cable (per DDC to UPS Power Supply). as per technical specification etc. as required.
5.0 FFTG Works FFTG-01.00 Fire pumps & Acce, Yard Hydrant, Internal Hydrant, Hose reel & Sprinkler System Supply, Installation, Testing and Commissioning of Electric driven Pump (Hydrant & Sprinkler pump) suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, centrifugal, end suction back pull out pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 90 m. head conforming to IS standards. b) Casing - CI, Imperller-Bronze, Shaft - SS 410, Mechanical seal c) Squirrel cage induction motor with suitable HP with synchronous speed 2970 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. d) Common Base plat for Pump and motor and coupling, coupling guard, rubber belows, anti-vibration arrangement, cables & other accessories as required for complete Installation of pump set. e) Suitable cement concrete foundation with cement concrete plaster complete with anti-vibration arrangement.
Supply, Installation, Testing and Commissioning of Diesel Engine driven fire pump (Standby Pump) suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, centrifugal, end suction back pull out pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 90 m. head conforming to IS standards. b) Casing - CI, Imperller-Bronze, Shaft - SS 410, Mechanical seal c) Diesel Engine with suitable HP with synchronous speed 2300 RPM, diesel tank, battery, exhaust pipe with insulation with all required accessories. d) Common Base plat for Pump and motor and coupling, coupling guard, rubber belows, anti-vibration arrangement, cables & other accessories as required for complete Installation of pump set. e) Suitable cement concrete foundation with cement concrete plaster complete with anti-vibration arrangement.
Providing, Fixing, Testing and Commissioning of Electric driven pump Hydrant & Sprinkler( pressurization pump) suitable for automatic operation and consisting of following: complete in all respect as required. a) Vertical inline pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 180 lpm at 90 m. head conforming to IS standards. b) Casing - SS 304, Imperller-SS 304, Shaft - SS 304, Mechnical seal c) Squirrel cage induction motor with suitable HP with synchronous speed 2900 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. d) Common Base plat for Pump and motor and coupling, coupling guard and other accessories as required for complete installation of pump set. e) Suitable cement concrete foundation duly plastered with anti vibration pads.
Supply, Installation, Testing and Commissioning of 150 mm dia. Pressure Gauge (for all pipes) of range 0 - 15 Kg / cm² Polished Stainless Steel Case with positive seal against weather, moisture & dust, with Glycerine filled, screwed, nipple, isolation valve, U-type stainless steel siphon tube and complete with necessary as required.
Supply, Installation, Testing and Commissioning of Pressure Switches for automation of fire pumps. Pressure switches shall be SPDT type suitable for single phase supply with diaphragm, IP 67 protection as required.
M.S. Above Ground Pipe Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, Above ground M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. a) 200 mm dia. (wall thickness 6.3 mm)
b) 150 mm dia.
c) 100 mm dia.
d) 80 mm dia.
e) 65 mm dia.
f) 50 mm dia.
g) 40 mm dia.
h) 32 mm dia.
i) 25 mm dia.
M.S. Under Ground Pipe Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, Under ground M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges / wrapping coating 4mm thick / 150mm width as per IS:10221 etc., and two coats of anticorrosive primer and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. a) 150 mm dia.
b) 100 mm dia.
c) 80 mm dia.
Supply, Installation, Testing and Commissioning of C.I. Y type Strainer with S.S. Screen/SS 304 having 1.2mm perforation with require accessories. a) 200 mm Dia.
Supply, installation, testing and commissioning of C.I. Butterfly valve (IS:13095 , PN 16) with flanges, nut bolts, gaskets complete as required. a) 150 mm dia.
b) 100 mm dia.
c) 65 mm dia.
Supply, Installation, Testing and Commissioning of C.I. Sluice valve (IS: 14846,PN 16) with flanges, nut bolts, gaskets complete as required. a) 200 mm dia.
b) 150 mm dia.
c) 80 mm dia.
d) 65 mm dia.
Supply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve (PN 1.6) a) 200 mm dia.
b) 150 mm dia.
c) 100 mm dia.
d) 65 mm dia.
Supply, Installation, Testing and Commissioning of Air vessel of size 450 x 2000 mm long fabricated from 8 mm thick M.S Plate and installed vertically on suitable legs with required necessary valves and connection with required accessories.
Supply, Installation, Testing and Commissioning S.S. Fire Hydrant Single Landing Valve with 80 mm N.B. flanged inlet, SS spindle controlled 63 mm dia female instantaneous outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories Conforming to IS:5290. Including fixing with anchor fastener and flanged tapping complete as required.
Supply, Installation, Testing and Commissioning of Fire Hose Cabinet wall mounting type 18swg (750 mm x 600 mm x 250 mm deep) with required accessories as per specification.
Supply, installation, testing and commissioning non-percolating rubber reinforced lined Fire Hose pipe (as per IS : 636) of 63 mm dia and 1no.x15 mtrs long. The hose shall be rated for burst pressure of 38 kg/sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903) bound as per specification.
Supply, Installation, Testing and commissioning of 63 mm dia instantaneous pattern SS short branch pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required by the Local Fire Authority.
Supply, installation, testing and commissioning of First Aid Hose Reel (25 kg/cm²) conforming to IS:884 comprising of hose reel drum, 8 mm shut off nozzle, hose reel tubing type-3 as per IS: 444 of 25 mm dia x 30 mtr. long, painting, fixed wall type with fixing bracket, anchor fastener, bolts & nuts etc. complete as required by Local Fire Authority.
Supply, installation, testing and commissioning of forged brass Ball Valve.(PN 25) a) 25mm dia
Supply, Installation, Testing and Commissioning of 25mm Brass Sprinkler test and Drain Valve (300 PSI) assembly with all required fittings as per drawing and as directed.(UL listed & FM approved)
Providing & fixing Gun Metal fire brigade suction hose coupling (draw-out connection) with 2 nos 63 mm dia instantaneous type male couplings complete as per specification/drawings and as directed by Engineer In Charge.
Supply, installation, testing and commissioning of Cast Iron Two Way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut bolts etc. complete as required.
Supply, installation, testing and commissioning of Cast Iron Four Way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut bolts etc. complete as required.
Supply, Installation, Testing and Commissioning of Gun Metal Air Release Valve with necessary fittings. Size: 25 mm (For Riser)
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150 mm dia
Supply, Installation, Testing and commissioning of Quartzoid Bulb type Sprinkler Heads. a) Pendent Sprinkler with rosette plate 68°C - K-80 - standard response - UL listed
b) Upright Sprinkler 68°C - K-80 - standard response - UL listed
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. a) Size: 1000mm
b) Size: 1200mm
c) Size: 1500mm
Supply, Installation, Testing and commissioning of Vane type Flow Indicating Switch with fittings, Flanges, nut-bolts, washers etc. as per requirement. (UL listed & FM approved) a) 150 mm dia.
b) 100 mm dia.
Supply, installation, testing and commissioning of Pump on/off Remote switches to each internal hydrant valve with required accessories.
Supply, installation, testing and commissioning of XLPE insulated FRLS copper armoured Cable from each Pump on/off switches to Panel with all necessary accessories. Size: 4 core x 2.5 sq. mm
Providing and laying Brick Masonary Valve Chamber of inside dimension 1.0M x 1.0M x 1.2M deep with 9" thick wall 20mm thick plastered from inside and 6mm thick MS cover with handle. Top cover to be painted with Red oxide primer and shall be capable of with stand 20 tone load.
FFTG 02.00 Fire Extinguisher and Exit Signages Supply, installation, testing and commissioning of Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 kg confirm to IS:15683, stored pressure, squeeze type with ISI marked fitted with required accessories including wall suspension brackets.
Supply, installation, testing and commissioning of ABC (MAP 90%) type 6 kg stored pressure, squeeze type confirm to IS:15683, with ISI marked fitted with required accessories including wall suspension brackets.
Supply and fixing of ISI mark (IS:15683) Clean Agent HCF236fa, 10 Kg modular type ceiling mounted Fire extinguisher , Stored pressure type with pressure guage.
Providing, fixing AUTO GLOW photo luminescent Signage's as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: a) Fire lift: size: 100 X 300mm
b) In case of Fire, do not use lift, use staircase: 200 X 200mm
c) Fire Equipment : size: 100 X 300mm
Supply Of Self Contained Rechargeable SWGS Emergency Egress Routes Lighting With the 1X 3 W LED Lamp. The equipment Shall Surface/hanging mounted with all require Accessories with requirement for the Fire and Safety code of practice with 3 Hours backup. Nominal Input Voltage 230 +-10 % to 240V A.C. +-10 % 50 Hz +-10 % as specified in specification. (Size:300 x 180mm)
Getting Approval/NOC of Fire protection system (Hydrant, Sprinkler etc..) from local fire authority and any other relevant statutory authority at initial and various other stages of work, including preparation of report/drawings as per fire authority.
Design, Supply, Installation, Testing, and Commissioning of Chiller Plant Manager suitable to control 04 nos. of Water cooled chillers with VFD (2 Working + 2 Future), 4 Nos. Twin Cell Cooling Towers (2 Working + 2 Future), 4 nos. of Primary Pumps (2 Working + 1 standby + 1 Future), 4 nos. of Variable Frequency driven Secondary pumps (2 Working + 1 standby + 1 Future) & 4 Nos. of Condensor Pumps (2 Working + 1 standby + 1 Future) as per HVAC BOQ. The CPM shall be a 32 Bit microprocessor based, programmable controller, factory pre-programmed system housed in a IP54 rated panel enclosure of suitable size (and qty). Shall have integrated color graphics display for display of plant graphics, facility to change settings etc. Shall have on-board EPROM memory expandable through add-on memory card like micro SD card capable of storing sampled plant data for 5 years. Shall be capable of communicating with 3rd party BMS through Bacnet / IP. Shall have at least 2 nos. of on-board integrators for integrating chillers, VFD through open serial protocal like modbus RTU, grundfos bus, Wi Lo bus etc. Embedded web-server facility shall be optional. Shall do the function of time based scheduling, load based start / stop, run time equalization, trip / fault detection and annunciation of the high side refrigeration plant, namely; chillers, pumps, motorized on / off isolation valves etc. It shall also control the pumping system & shall co-ordinate with the primary side. Shall calculate plant load based on chilled water return header temperature. Price to include lump sum supply and laying of 2C x 1.0 sq mm armored FRLS signal cable from field sensor / actuators up to controller.
Primary Chilled Water Pumping System: Supply, Installation, Alignment, Testing and Commissioning of End Suction Top discharge Back Pull out Centrifugal type Primary Chilled water pumps as specified. The pump shall be dynamically balanced and supplied with Flexible coupling with Guard, Corrossion resistant painted factory supplied MS baseframe with necessary vibration isolators and Rubber flexible bellows at suction and discharge nozzels; Pump shall be designed to operate for 15 MWC TDH; this TDH is assumed; Pumps shall be checked for Parallel Pumping Operation and checked for actual (vendor specific) Chiller Shell Pressure drop to arrive at actual TDH and Motor Ratings; Quoted price shall include cost of vibration isolation and all other associated accessories & duly insulated with insulation and finish similar to Chilled water piping Insulaiton specifications ; 1 No. - End Suction Top discharge Back Pull out type pump with bronze impellar - designed to operate at minimum 80% overall efficiency, S.S Shaft, CI body and mechanical seal. Lot - Closed cell nitrile rubber insulation of not less than 22 mm thick duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications. 2 Nos. - 150 mm dia dial type pressure gauges. With stainless steel binders & vibration dampers. 1 No. 4 Pole hi-efficiency - Suitable HP, Eff 1 Class TEFC IP 55 squirrel cage induction motor with class 'F' insulation, 1500 RPM synchronous speed, operating on 415 Volts + 10 %, 3 phase, 50 Hz A.C. supply. (3 working + 1 stand by) The price shall include supply & return pipe side expansion bellows. Lot - Mounting frame with anit vibration pads
Condenser Cooling Water Pumping System with accessories Supply, Installation, Alignment, Testing and Commissioning of End Suction & Top discharge Back Pull out Centrifugal type Condenser Cooling water pumps as specified. The pump shall be dynamically balanced and supplied with Flexible coupling with Guard, Corrossion resistant painted factory supplied MS baseframe with necessary vibration isolators and Rubber flexible bellows at suction and discharge nozzels; Centrifugal Pump with above accessories. Pumps shall be checked for Parallel Pumping Operation and checked for actual (vendor specific) Condenser Shell Pressure drop to arrive at actual TDH and Motor Ratings; performance curves will be attached with the Bid. 1 No. - End Suction Top discharge Back Pull out type pump with bronze impellar - designed to operate at minimum 80% overall efficiency, S.S Shaft, CI body and mechanical seal. 2 Nos. - 150 mm dia dial type pressure gauges. With stainless steel binders & vibration dampers. 1 No. 4 Pole efficiency - Suitable HP, Eff 1 Class TEFC IP 55 squirrel cage induction motor with class 'F' insulation, 1500 RPM synchronous speed, operating on 415 Volts + 10 %, 3 phase, 50 Hz A.C. supply. (3 Working + 1 Stand By) Lot - Mounting frame with anit vibration pads The price shall include supply & return pipe side expansion bellows. 1200 GPM / 20 M WC (2 Working + 1 Stand by + 1 Future)
Supplying, installing, testing and commissioning of FRP induced draft counter flow rectangular multicell type CTI approved FRP cooling tower with VFD of 300 TR heat rejection capacity multi cell and multi fan with PVC fillings with intergal louvers and drift eliminators open pan sutaible flow water distribution complete with hot FRP water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced two nos. axial flow type fan-direct driven with PVC blades & Al Alloy Hub driven IP55 TEFC 710 RPM vertical flange mount motor suitable for 415 ± 10 % V, 50 Hz, 3 phase supply; power / control wiring, earthing, drain, make up, quick fill connection and vibration isolation etc. as recommended by mfr. not less than tender specified requirements; Tower Design Capacity shall be 300 TR (equivalent THR) when designed for Temp Range = 4 °C, Cooling water Flow 1200 GPM and Leaving temp 32 °C at 28.0 °C design WBT; L/G ratio and Evaporative loss calculations shall be submitted along with the bid; Water Temp In - 36.0 °C, Water Temp Out - 32.0 °C, For Chiller Capacity - 300 TR, Flow Rate - 1200 GPM (2 Working + 2 Future) For Chiller TR / Flow Capacity - 300 TR / 1200 GPM
Chilled Water Expansion Tank Supplying, installation, testing and commissioning of Precharged Steel Closed expansion tank as per specification with replaceable heavy duty butyl rubber bladder, mounting stand with all necessary system connection & charging valve connection to facilitate on site charging. Tank to meet ASME Boiler & pressure vessel code along with all necessary valves & fittings complete as per technical specifications, drawings and requirements. - 500 Litres.
Insulation of above Expansion tank with Nitrile Rubber with Woven Glass Fibre Covering insulation complete as per technical specifications, drawings and requirements
Air & Dirt Separator Supply, Installation, Testing & Commissioning of Air & dirt Seperator as per specification Suitable for 350 mm Dia line size & 3600 GPM. at plant room complete as per technical specifications, drawings and requirements
Insulation of above Air & Dirt Seperator with Nitrile Rubber with Woven Glass Fibre Covering insulation complete as per technical specifications, drawings and requirements
Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 25 mm thick panels consisting of G.I. casing of thickness 0.8 mm outside layer and 0.8mm inside layer with polyurethene foam (PUF) insulation having a density of 40 Kg / Cu M factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward / backward curved centrifugal fan with 40 mm static, 4 row deep cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type air pre-filters having efficiency 90% down to 10 micron, belt with TEFC drive motor (Eff-1) suitable for 415+/-, 10% volts, 50 Hz, 3 phase, A.C. supply with starter panel, drain connections with drain valve, 2mm thick Stainless steel single sloping insulated drain pan (for zero water retention), Descaling valve, auto air purge valve, thermometers and pressure gauge at the inlet and outlet of coilss, supplied with factory fitted matching size 2 way ON / OFF actuator type Brass / Control valve / Cu piping with required couplings and ends flanged to fit CHW In / Out piping, necessary vibration isolation arrangement, Supply air side canvass connection with damper etc, complete as per specifications. Price shall be complete with Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, Automanual Status, Temperature Indicator availability on Panel with BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan and duly internally wired and tested. Followings are capacities. 4.15 TR / 2230 CFM 65mm Static Pressure
2.96 TR / 1660 CFM 65mm Static Pressure
8.50 TR / 1700 CFM 65mm Static Pressure at Ground Floor
10.20 TR / 1750 CFM 65mm Static Pressure at First Floor
10.80 TR / 2150 CFM 65mm Static Pressure at First Floor
13.10 TR / 2150 CFM 65mm Static Pressure at Second Floor
13.00 TR / 2450 CFM 65mm Static Pressure at Second Floor
15.60 TR / 2550 CFM 65mm Static Pressure at Third Floor
13.00 TR / 2450 CFM 65mm Static Pressure at Third Floor
6.00 TR / 1200 CFM 65mm Static Pressure at Fourth Floor
16.00 TR / 2950 CFM 65mm Static Pressure at Fourth Floor
15.10 TR / 3000 CFM 65mm Static Pressure at Fifh Floor
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling suspended Chilled Water Cassettes, 4 way flow type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters 70% down to 20 micron, Hydrophilic Al fins and Copper Chilled Water Cooling Coil section with minimum 2 Row and minimum 13 FPI, in-built condensate drain pump, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent control cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 electrothermic / motoric modular actuator (0 to 10 Volt DC Signal) fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. Unit shall be supplied with BMS compatible Digital Group Controller, necessary Networking Adapters and Gateway with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required.The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 400 CFM
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Ceiling Suspended Chilled Water Fan Coil Units as specified below with; Single Skin Fan Coil Units in standard construction with Fan section with DIDW multi blowers & energy saving Single Phase BLDC motor/ EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al type Copper Coil section with minimum 3 Rows and minimum 13 FPI Chilled / Hot Water Cooling Coil, pre-assembled valve station with set of brass ball valve with "Y" strainer set, Insulated extended L shaped Drain Pan, supplied with pre-calibrated matching size 2 way / Pressure independent modulating cum balancing valve of minimum PN25 rating with P/T plugs and minimum IP54 t electrothermic / motoric modular actuator (0 to 10 Volt DC Signal), fixed on FCU Cu piping with required couplings and ends flanged to fit CHW field In / Out piping and its compatible 24VAC control transformer; All valve assemblies are to be insulated with closed cell elastomeric nitrile rubber insulation. UNit shall be supplied with Digital Fan Coil Thermostat with Fibre water proof casing BMS compatible with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 400 CFM
Design, Supply, Lifting & Shifting at actual proposed location of site, Installation, Testing, Commissioning and Field Performance Validation of Decorative Wall Mounted type Chilled Water based High Wall type Fan Coil Units with energy saving Single Phase BLDC motor / EC Motor (Electronically Commuted Motor), Filter section with prefilters, Hydrophilic Al fins and Copper Chilled / Hot Water multi step Cooling Coil section with minimum 2 Row and minimum 13 FPI Chilled Water Cooling Coil, combination of Automatic/ Dynamic Balancing valve and an in-built 2 way ON / OFF control valve of minimum PN 16 rating with pair of brass ball valve with "Y" strainer set, fixed outside FCU, Cu piping with required couplings to fit CHW field In / Out piping; All piping are to be insulated with closed cell elastomeric nitirile rubber insulation. Unit shall be supplied with Digital Display type cordless remote and capable of connecting with BMS with interface modbus protocol to connect the DDC panel (230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display) and supplied with 10 RMT cable from Controller to FCU as required. The Performance of units should be certified by a reputed third party agency and available for witness testing facility at manufacturer's factory. 300 CFM
Supply, installation, testing and commissioning of cabinet type Floor Mounted / Loft Mounted Type single skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection along with damper at suction side & descharge side cowl; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 5000 CFM / 40mm Static Pressure for Toilet
Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly. The Fan assembly along with motors should be tested for Temperature range: 300 °C / 2 Hours for Smoke Evacuation as per EN 12101-3. Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. 21000 CFM / 15mm Static Pressure For Smoke Evacuation of Lecture Theatre
Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly.Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. All other fan Floor mounting accesories will be provide with the fan. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested. 30000 CFM / 30mm Static Pressure
SUB HEAD 'C' - CHILLED WATER PIPING INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 °C mean temperature class ‘O’ insulation applied by suitable adhesive, over and above glass cloth to be applied, complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 400mm dia.(32 mm thick insulation)
350mm dia.(32 mm thick insulation)
300mm dia. (32 mm thick insulation)
250mm dia.(32 mm thick insulation)
200mm dia.(32 mm thick insulation)
150mm dia. (32 mm thick insulation)
125mm dia.(32 mm thick insulation)
100mm dia. (32 mm thick insulation)
80mm dia.(32 mm thick insulation)
65mm dia(32 mm thick insulation)
50mm dia(32 mm thick insulation)
40mm dia. (32 mm thick insulation)
32 mm dia(19 mm thick insulation)
25 mm dia(19 mm thick insulation)
19 mm dia(19 mm thick insulation)
INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. providing and erecting BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified 250mm dia.
200 mm dia
150mm dia.
125mm dia.
100mm dia.
80mm dia.
65mm dia.
50mm dia.
40mm dia.
Providing and erecting BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 200 mm dia
150mm dia.
125mm dia.
100mm dia.
80mm dia.
65 mm dia
50mm dia.
40 mm dia
Providing and erecting NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. 200mm dia.
150mm dia.
Providing and erecting Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 200mm dia.
80mm dia.
65mm dia.
50mm dia.
40mm dia.
32mm dia.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing & fixing in position the mercury in glass industrial type thermometers.
SS BALL VALVE complete with Flanges Nutbolts with SS Body and Working parts. 40mm dia.
32 mm dia.
25 mm dia.
Supplying, fixing, testing and commissioning of Automatic Air Purge Valve at AHU chilled water outlet pipe duly insulated to the same specifications as the connected piping and adequately supported as per specifications. 20mm dia.
SUB HEAD 'D' - CONDENSER WATER PIPE CONDENSER WATER PIPE Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:- The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 400 mm dia.
350 mm dia.
300mm dia.
250 mm dia
200mm dia.
150mm dia.
125mm dia.
100mm dia.
65mm dia.
50mm dia.
40mm dia.
VALVES WITHOUT INSULATION Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Providing and erecting BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 400 mm dia.
250 mm dia.
150 mm dia.
65 mm dia.
50 mm dia.
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe & PN 16 pressure rating for hot water circulation as specified. 250mm dia.
Providing and erecting NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified. 250mm dia.
Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC, and upto 20mA electric signal and providing similar transduced feedback output to control system as required. 250mm dia.
200mm dia.
65mm dia.
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. 80mm dia.
65mm dia.
50mm dia.
40mm dia.
32mm dia.
Pot STRAINER as specified with SS Jali complete with pair of flanges neoprene gasket. 400mm dia.
SS BALL VALVE complete with Flanges Nutbolts with SS Body and Working parts. 40mm dia.
25 mm dia.
SUB HEAD 'E' DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sq. mm) for integration within AHU room Damper
Actuator
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers complete as per specifications and size & shape as per site requirement and approved design.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as per specifications and size & shape as per site requirement and approved design.
Supplying, fixing testing commissioning of supply air diffuser of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core and size & shape as per site requirement and approved design.
Supplying, fixing testing commissioning of Return air diffuser of powder coated aluminium without volume control dampers with anti smudge ring & removable core and size & shape as per site requirement and approved design..
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. (A) 200 mm dia.
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire Damper
Actuator
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19mm
Supplying and fixing 50mm thick aluminium foil faced resin bonded fibre glass insulation (on duct) of density 24 kg/cu.m or mineral wool insulation(non combustible) of density 44 kg/cum after applying two coats of cold setting adhesive (CPRX compound) sealing all joints with self adhesive aluminium tape & covering with 0.63mmx19mm GI wire mesh netting & butting all joints and laced with GI wire complete and finally covered with one layer of tar felt stuck with hot bitumen as per specifications and as required. (for outdoor applications)
Supplying & fixing 50mm thick TF quality expanded polystyrene for underdeck insulation on slab/wall /shaft exposed to sun/atmosphere as per specifications.
Supply & Installation at fixing of resing bonded slab & with company bonded black glass tissue faced for False Ceiling Insulation as per detail specifications - 50mm
SUB HEAD 'F' - AIR COOLED VARIABLE REFRIGERANT SYSTEM Supply, Installtion, Testing & Commissioning of Variable Refrigerant System. Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) 20 HP
Supply, installation, testing and commissioning of following minimum capacity VRV High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with noise level maximum 60 dB @min 400 cfm /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2 TR
Central wired Remote Control System
Supply installation testing commissioning Shielded Shielded Control Cables for VRV System with necessary ISI mark Medium class rigid PVC pipes with necessary accessories with termination in machine and control equipments. 2C X 1.5 Sq mm Shielded Armoured
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
SUB HEAD 'G' - Miscelleneous Works Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 50 mm dia.
40 mm dia.
32mm dia.
25 mm dia.
19 mm dia.
Providing and erecting Inverter based approved make split air-conditioning unit consisting of condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of extra supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes Eco Friendly green gas charging and 15A plug top & Remote Control & MS Stand) with necessary core cutting. (A) for 0.8 to 1.0 ton capacity
(1)For 3 Star Rating of current year (B) for 1.5 ton capacity
(1)For 3 Star Rating of current year (C) 1.7 to 2 ton capacity
MEDIUM VOLTAGE CABLE Supply, laying, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, stranded AL / Cu conductor Armoured cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building. The scope shall include: Delivery of the cables at site. Unloading at site store. Shifting of cable from site store to place of installation. Excavation in hard or soft murrem / rocky area upto required depth, supply and laying of protection bricks, supply and backfilling with fine sand, leveling the ground to match with the existing condition. Laying of cable in the excavated trenhc / prepared trench / cable tray / duct / hume pipe / channel / floor trunks when laid inside or outside the building. Connection of cable. Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. Testing of insulation and continuity of cable and submission of reports to the client's representative. To prepare submission drawing and to take approval of consultant at each stage. To prepare & submit as-built drawing and handing over document to end user. 3C X 4 SQ. MM. CU XLPE CABLE
3C X 25 SQ. MM. CU XLPE CABLE
3.5C X 70 SQ. MM. AL XLPE CABLE
3.5C X 240 SQ. MM. AL XLPE CABLE
4C X 6 SQ. MM. CU XLPE CABLE
4C X 10 SQ. MM. CU XLPE CABLE
4C X 16 SQ. MM. CU XLPE CABLE
CABLE END TERMINATION AND CONNECTION Supply, fixing, connection, testing & commissioning of single compression brass cable glands and crimping type Bimetalic lugs / sockets with necessary tools and equipments as specified in specifications and IS. The glands and lugs / sockets shall be suitable for cable size and type mentioned above. The job also includes, if necessary, supply and fixing of extension busbar of same material on circuit breaker or panel board terminal / connector to connect more than one no. of parallel cables or to connect higher size cable to lower size unit. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh. 3C X 4 SQ. MM. CU XLPE CABLE
3C X 25 SQ. MM. CU XLPE CABLE
3.5C X 70 SQ. MM. AL XLPE CABLE
3.5C X 240 SQ. MM. AL XLPE CABLE
4C X 6 SQ. MM. CU XLPE CABLE
4C X 10 SQ. MM. CU XLPE CABLE
4C X 16 SQ. MM. CU XLPE CABLE
CABLE TRAYS Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 600 x 100 made out of 2 mm thick ladder type
450 x 100 made out of 2 mm thick ladder type
300 x 100 made out of 2 mm thick ladder type
150 x 100 made out of 2 mm thick ladder type
EARTHING Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover.(approved make OEM has to submit test certificate including value of earth resistane of installation. -Length of Pipe : 3 Mtrs. -Back filling Compound :2 nos Bags of 25 Kg
Earth wire/strips : Supply and laying cu. earthing required size strips for interconnecting the earthing stations, panels, DB's etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with : a) Fixing accessories. b) Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. 25 x 3 mm/ 32X6mm / 50x6mm CU. strip/ 38x6 Cu earth link
SUB HEAD 'I' - OPERATION & MAINTENANCE SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. Only Opearation Cost During DLP
1st Year after DLP
2nd Year after DLP
3rd Year after DLP
4th Year after DLP
5th Year after DLP
PIPE WORK Providing, laying & jointing in position PVC/ HDPE pipe conforming to ISI standard and suitable for the respective working pressures with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instruction, PVC pipe 90mm-6 kg/cm2
PVC pipe 75mm-6 kg/cm2
PVC pipe 63mm-6 kg/cm2
PVC pipe 50mm-6 kg/cm2
PVC pipe 40mm-6 kg/cm2
Earth work excavation and refilling 300x450mm
SPRINKLERS & ACCESSORIES Providing & fixing of PGP ULTRA, Pop-up ROTOR sprinkler having variable adjustable arc (50 to 360 degrees)nozzle capable of covering 4.9m -14.0 m at 2.5 Bars with discharge rate of 0.02- 0.891Lps.The Rotor body, stem, nozzle and screen shall be constructed of heavy-duty, ultraviolet resistant plastic with small exposed cover.
Providing & Fixing of SJ- 712, 3/4" Pop up Connecting Four Elbow Swing joint Assembly. The fittings shall be made of UV resistant thermo plastic.
Providing and fixing of PP service saddle of varying size.3/4'
Providing & fixing of Rotatory Pop up having colour coded MP Rotator nozzle with multiple stream water spray capable of covering 2.5m- 10.7m with Matched Precipitation Rate .The Spray Head body shall be constructed of heavy-duty, ultraviolet resistant plastic and stainless steel spring with mutifunctional wiper seal with small exposed cover.
Providing & fixing of PS- Ultra, Pop up spray head bodies, having features an encased plastic 'cage' to provide unmatched resistance to grit,with high efficiency ADJUSTABLE nozzle capable of covering 1.2M -5.2m at 1.0 - 2.1 Bars, pressur. Additionally Two-piece ratchet mechanism, Features is Precision controlled flush at pop-down clears debris from unit, Construction of time-proven UV_resitant plastic.
Providing & Fixing of SJ- 512, 1/2" Pop up Connecting Four Elbow Swing joint Assembly. The fittings shall be made of UV resistant thermo plastic.
Providing and fixing of PP service saddle of varying size.1/2'
DRIP LATRAL AND ACCESSORIES Supply and fixing of flexible Blank tubing and resistance to UV damage and algae growth black in colour 16 mm size. With all fittings and accessories.( Dripline 16 mm 50 cm 3.8 lphinline lateral)
Supply and fixing of flexible Blank tubing and resistance to UV damage and algae growth black in colour 16 mm size. With all fittings and accessories.( Plain Dripline 16 mm plain lateral)
Supply and fixing of PC dripers 8lph
Supply and Fixing Rod Comes Pre -Bent or plastic lateral stack to Staple Distribution Tubing , Drip Line to Finished Grade.
VALVES & ACCESSORIES Providing and fixing of PVC Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem non mechanical ,with a base which permits maximum penetration into the valve of size 63mm.
Providing and fixing of PVC Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem non mechanical ,with a base which permits maximum penetration into the valve of size 50mm.
Providing & fixing of Isolation Valve in mainline for bypass and flow diversion of approved quality
Providing & fixing of a double acting 1" Air release valve, The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar. Including service saddle and riser assembly.
Providing & fixing of 12" Rectangular Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout
Providing & fixing of 10"Round box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout
Providing & fixing of 6"Round box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout
Providing & fixing of Brass Quick coupling valve made up of solid brass with locking cover corrosion resistant and stainless steel spring. Including service saddle and riser assembly.
Providing & fixing of Brass Key threads into top of QCV to provide water access And Brass Swivel Elbow
FILTERATION UNIT Providing & Fixing of Sand Filter 40m3/hr , MANUAL
Providing & Fixing of DISC FILTER- with capacity matching pump design flow having an suitable inlet connections , to create a helical effect in the incoming water ,spinning particulate in suspension away from the filtering element and so minimizing cleanings frequency ,3/4" outlet for flushing at bottom of filter & maximum working presure of 10 Bars. with pressure gauge.
PUMPING UNIT Providing & Fixing of (Monoblock/Openwell submersible) pumpset of having discharge 6.5 lps@48 mtr head . suitable for pumpset having panel box and fixed alongwith following accessories starter ,start / stop push buttons , Ammeter, Voltmeter , Indicating lamps, MCB , with cable, etc.
Providing and fixing of control panel suitable for pumpset having panel box and fixed alongwith following accessories starter ,start / stop push buttons , Ammeter, Voltmeter , Indicating lamps, MCB , with cable, etc.
Providing & Fixing of ,Suction ,Delivery & Header Pipe
Providing & fixing of control Valve /Butterfly Valve in mainline for bypass and flow diversion of approved quality 3"
Providing & fixing of Non Return Valve to prevent back flow 3"
Providing and fixing of Pressure Release Valve 2"
Automation Equipment Supply and fixing of Direct burial 14 AWG x 2C cable for two way communication between controller and decoders
PVC conduit Pipe complete 32 mm
Supply and fixing of ICC2 MEDIUM CONTROLLERS WITH EZDM EZ Decoder Output Module internal transformer control system , cycle +soak, Raindelay, SOLARSYNC Mini weather station, controlling upto 1 master valve with diagnostic feature in wire shorttest ,voltage test at stations, standard accessories complete
Supply and fixing of EZ1 1 Station Decoder
Supply and fixing of 1.5" Solenoid globe Valves with fabric reinforced diaphram and rugged PVC construction ,compatible with and slow closing to prevent water hammer,pressure rating upto 10 bar with 24AC solenoid, with provision to attach Pressure Regulator
Supply and fixing of 2" Solenoid globe Valves with fabric reinforced diaphram and rugged PVC construction ,compatible with and slow closing to prevent water hammer,pressure rating upto 10 bar with 24AC solenoid, with provision to attach Pressure Regulator
Supply and fixing of direct bury -on wire connector with strain relief , with waterproof silicon sealant.
Supply and fixing of SOLARSYNC COMPATIBLE WITH PRO-C, ICC AND I-CORE CONTROLLERS, COMES COMPLETE WITH SENSOR PLATFORM AND CONTROLLER INTERFACE, AUTOMATICALLY RESPONDS TO LOCAL WEATHER CHANGES .
Supply and fixing of ACCU-SYNC-ADJ ACCU-SYNC PRESSURE REGULATOR, ADJUSTABLE PRESSURE MODEL 1.4–7 BAR (20–100 PSI), WORKS WITH ANY HUNTER VALVE
Supply and fixing of copper grounding rod, clamps, charcoal and all requisite accessories complete
Supply and fixing of Pump relay 24 AC PLA relay
Clearance of site by removal of business vagetation etc & disposal of sam outside the project site as directed
Supplying and stacking of good earth at site including royalty & carriage upto 1 KM (earth measured in stack will be reduced by 20% for payment) Total top soil in plantation areas upto the depth of 20cm
Supplying and stacking of manure on site including royalty & carriage upto 1.5KM (manure measured in stacks will be reduced by 8% for payment)
TREES The rate includes for transprotation at site, excuvation of 0.9x0.9x0.9m.pits for trees. Filling pits with prepared manure soil (ratio 1:2, one part sludge plus two parts good earth by volume) supply, transportation & mixing of soil improvement nutrients including manure as required and inside coat of Aldrin in all pits, flooding with water, dressing including removal of rubbish &surplus earth if any with all leads and lifts, planting and stacking in full & final location including all locations specified
SHURBS, CLIMBERS & SPECIMEN PLANTS The rate includes for transportation of site excavation of 0.6x0.6x0.6m pits for large shrubs and climbers. Filling pits with prepared manure soil in the ration 1:2 (one sludge two good earth by volume) Supply, transportatioin & mixing of soil imporvement nutrients including manure as required and removal of rubbish & surplus. Inside coat of Aldrin in all pits, flooding with water, dressing including earth if any with all leads & lifts, painting & stacking in full & final location.
GROUND COVER The rate includes for transportation to site, excavation of beds upto 0.3m depth. Filling with prepared manure soil in the ratio 1:2 (one part of sludge to two parts of good earth by volume).Supply, transportation & mixing of soil improvement nutrients includ8ing manure as required and inside coat of \Aldrin in all pits, flooding with water, dressing including removal or rubbish & surplus earth if any with all leads & lifts, planting & stacking in full & final location including all locations specified.
LAWN Preparation of lawn of grassing by excavation to a depth of 0.30m. Removing all foreign bodies over 50mm dia. Refilling with the mix of earth and manure in ratio 2:1. Greade lawn areas to finish levels as indecated on grading plans. All lawn areas shall slope to drain. Where on grades are shown areas shall have a smooth and continual grade between existing or fixed control (suchas walks, curbs,catch basins, elevations at steps or building) and levels shown on plans, Roll, scanfy, rake and leven as necessary to obtain true, even lawn surface. All finish grades shall meed approval of the Project Engineer before grassing is done.
YASHNAND ENGINEERS AND CONTRACTORS PVT. LTD.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid