Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.6 CrAccepted-AOC CANADA BUILDING 224 DR D N ROAD MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹11.6 Cr | 1 | Accepted-AOC Emerged as the Lowest Bidder after Reverse Auction |
| 2 | 2₹11.7 CrRejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹11.7 Cr | 2 | Rejected-Finance As the Bidder is not the Lowest Bidder. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not meets the ENIT criteria as per para 2D (III-c and f) |
Tender Value
₹11.1 Cr
EMD Value
₹22.1 L
Closing Date
4 Oct 2022, 6:00 pmClosed
AGM(Engg-E),ER
O/o ED (Engg)-ER and NER, CHQ - AAI, Safdarjung Airport, New Delhi
Upgradation of CAT-I lighting system to CAT-II lighting system at Swami Vivekanand International Airport, Raipur
2022_AAI_127260_1
AAI/CHQ/ER/E-E/RPR/CAT-II/22
Open Tender
Electrical Works
270 days
SVI Airport
As per Tender Document
30 documents required · 30 mandatory
₹3,540
₹22.1 L
Yes
23 Mar 2023
30 Aug 2022
10 Oct 2022
31 Aug 2022
4 Oct 2022
13 Sept 2022
31 Aug 2022 - 6 Sept 2022
Amount
Supply of Runway CENTRE LINE (CL) light Bidirectional (RED/White) 8 inch dia.
Supply of Runway CENTRE LINE (CL) light Bidirectional (White/White) 8 inch dia.
Supply of FAA Certified Inset type fittings suitable for Uni directional high intensity TOUCH DOWN ZONE (TDZ) a) Unidirectional touchdown light (White) 8 inch dia.
Supply of 12 inch dia Inset type fittings suitable for Uni directional high intensity SIDE ROW (SR) (RED Color)
Supply of Elevated type fittings suitable for Uni directional high intensity SIDE ROW (SR) (RED Color)
Supply of 12 inch dia Inset type fittings suitable for Uni directional high intensity APPROACH LIGHTS FOR EXTENDED RWY CENTRE LINE (White Color)
Supply of Elevated type fittings suitable for Uni directional high intensity APPROACH LIGHTS FOR EXTENDED CENTRE LINE (White Color)
Supply of 12 inch dia Inset type fittings unidirectional suitable for high intensity THRESHOLD (Green Color)
Supply of elevated type Uni-Directional Runway threshold wing bar (Green Color)
Supply of Inset type fittings unidirectional suitable for high intensity END light fitting (Red Color)
Supply of Inset type Uni directional Stop Bar light fitting (Red Color)
Supply of Unidirectional Runway guard light fitting with two elevated type fixed focus High Intensity fixture
Supply of 2 x 4 sqmm secondary lead made out of multi stranded copper conductor
Supply of 6 sq.mm 5 KV grade Single Core unarmoured Primary Circuit Cable
Supply of 6 sqmm, 5 KV grade plug and receptacle of type I, class 'B' connector
Supply of Constant Current Regulator (CCR) of micro processor controlled, thyristor type 2.5 KW
Supply of Constant Current Regulator (CCR) of micro processor controlled, thyristor type 4 KW
Supply of Constant Current Regulator (CCR) of micro processor controlled, thyristor type 5 KW
Supply of Constant Current Regulator (CCR) of micro processor controlled, thyristor type 7.5 KW
Supply of Constant Current Regulator (CCR) of micro processor controlled, thyristor type 10 KW
Supply of Constant Current Regulator (CCR) of micro processor controlled, thyristor type 20 KW
Supply of Constant Current Regulator (CCR) of micro processor controlled, thyristor type 30 KW
Design and SITC of ALCMS System
Supply of Isolating transformer - 45Watt 6.6/6.6 Amps
Supply of Isolating transformer - 65Watt 6.6/6.6 Amps
Supply of Isolating transformer - 100Watt 6.6/6.6 Amps
Supply of Isolating transformer - 200Watt 6.6/6.6 Amps
Supply of Isolating transformer - 300Watt 6.6/6.6 Amps
Supply, Laying, Testing & Commissioning of 4 pair CAT 6 cable
Supply, installation, testing & commissioning of Guidance signage board (lP 65 prorection) complying to ICAO standard
Supply of 1.1 KV grade XLPE insulated, PVC sheathed, armoured Copper conductor cable 3 C x 10 Sq. mm.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed, armoured Copper conductor cable 3 C x 16 Sq. mm.
Supply of 1.1 KV grade XLPE insulated, PVC sheathed, armoured Copper conductor cable 3 C x 35 Sq. mm.
Installation, testing and commissioning of following sizes inset fitting Fitting size up to 8 "
Installation, testing and commissioning of following sizes inset fitting Fitting size above 8" up to 12 "
Installation, testing & commissioning of Elevated type approach / runway edge / threshold / end / taxiway light fixtures/ Runway Guard light
Installation, Testing & Commissioning of CCR of capacity 2.5 KW to 30 KW
Supply of rectangular C.I. Isolating Transformer housing box of Size 600mm (l)x 350mm(w) X450mm(h)
Installation of rectangular C.I. Transformer housing box of Size 600mm x 350mm X 450mm height
Supply of Cast iron Isolating Transformer housing box, water tight round type, metal container of outside dia 330 mm, height 450 mm
Installation of CI housing box of size 330 mm dia and 450 mm deep
Laying of one number PVC/XLPE insulated and PE sheathed primary circuit cable of 5 KV grade of following size in the existing RCC/ HUME/ METAL pipe/ HDPE Pipe/ Open masonary duct Single Core 6.0 sq. mm
Kerf cutting with machine in taxiway/runway/apron of PQC/bituminous surface of depth upto 100 mm and width upto 25 mm for 1 or 2 nos secondary lead AFL cable
Kerf cutting with machine in taxiway/runway/apron of PQC/bituminous surface of depth upto 150 mm and width upto 25 mm for 3 or 4 nos secondary lead AFL cable
Laying of one number 2 X 4 sq mm AFL secondary cable along with 1 X 4 sq mm earth cable of voltage grade not exceeding 1.1 KV in the existing RCC / HUME / METAL / GI / HDPE pipes
Supply and laying of follwing size double wall corrugated high density polyethylene (DWC HDPE pipe) pipe OD 63 mm/ ID 50 mm
Supply and laying of follwing size double wall corrugated high density polyethylene (DWC HDPE pipe) OD 50 mm/ ID 38 mm
Supply and Fixing of secondary Connectors (male & Female) of size 2 x 4 Sq.mm
Earthing with 'B' class G. I. earth pipe 4.5 mtrs. long x 40 mm dia
Supply & laying earth connections from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G. I. pipe
Supply and fixing 6 SWG G. I. wire on surface or along with primary AFL Cable for loop earthing
Supply and laying of green color single core 2.5 Sq.mm PVC insulated copper conductor earth wire
Making field connection by crimping of 6 sq. mm plug & receptacle with existing 6 sq. mm single core copper conductor primary airfield cable
Taking GPS based co-ordinates on complete length of main runway, cable route etc by using total station and identifying the locations of light fixtures, route of cable etc
Numbering of Airfield Light Fixtures on the base/ top surface/ RCC foundation of light fixture with good quality of black color enamel paint
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455 mm x 610 mm internal dimensions
Supply and Laying of HDPE pipe of 100 mm dia PN-10 as per IS 4984 by Horizontal Directional Drilling (HDD) method in soft soil
Supply, Installation, Testing & Commissioning Totally Type Tested Panel (Form -4B Construction) complying to IEC: 61439-1/2 cubicle type LT panel
Operation and routine maintenance of complete ALCMS system alongwith 30 Nos of CCRs, workstations,networking panel etc. First year (during DLP)
Operation and routine maintenance of complete ALCMS system alongwith 30 Nos of CCRs, workstations,networking panel etc. Second year (during DLP)
Operation and routine maintenance of complete ALCMS system alongwith 30 Nos of CCRs, workstations,networking panel etc. Third year (during first year of CMC)
Operation and routine maintenance of complete ALCMS system alongwith 30 Nos of CCRs, workstations,networking panel etc. Fourth year (during second year of CMC)
Operation and routine maintenance of complete ALCMS system alongwith 30 Nos of CCRs, workstations,networking panel etc. Fifth year (during third year of CMC)
Operation and routine maintenance of complete ALCMS system alongwith 30 Nos of CCRs, workstations,networking panel etc. Sixth year (during fourth year of CMC)
Operation and routine maintenance of complete ALCMS system alongwith 30 Nos of CCRs, workstations,networking panel etc. Seventh year (during fifth year of CMC)
AICMC of complete ALCMS System. (Rate quoted for 12 months ) First Year after DLP
AICMC of complete ALCMS System. (Rate quoted for 12 months ) Second Year after DLP
AICMC of complete ALCMS System. (Rate quoted for 12 months ) Third Year after DLP
AICMC of complete ALCMS System. (Rate quoted for 12 months ) Fourth Year after DLP
AICMC of complete ALCMS System. (Rate quoted for 12 months ) Fifth Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating less than 10 KW (Rate quoted for 12 months ) First Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating less than 10 KW (Rate quoted for 12 months ) Second Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating less than 10 KW (Rate quoted for 12 months ) Third Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating less than 10 KW (Rate quoted for 12 months ) Fourth Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating less than 10 KW (Rate quoted for 12 months ) Fifth Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating 10 KW to 20 KW (Rate quoted for 12 months ) First Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating 10 KW to 20 KW (Rate quoted for 12 months ) Second Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating 10 KW to 20 KW (Rate quoted for 12 months ) Third Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating 10 KW to 20 KW (Rate quoted for 12 months ) Fourth Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating 10 KW to 20 KW (Rate quoted for 12 months ) Fifth Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating 30 KW (Rate quoted for 12 months ) First Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating 30 KW (Rate quoted for 12 months ) Second Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating 30 KW (Rate quoted for 12 months ) Third Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating 30 KW (Rate quoted for 12 months ) Fourth Year after DLP
AICMC of Microprocessor based Constant Current Regulators (CCRs) of rating 30 KW (Rate quoted for 12 months ) Fifth Year after DLP
Bidder Name
Amount in Words
AMA Private Limited
Manish Electricals
AMA Private Limited
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid