Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
9 Nov 2020, 11:15 amClosed
EE EnM WS NW
MU BLOCK PITAMPURA
Internal n External Electrification with all accessories at MLA office in Mangol Puri AC 12
2020_DJB_196212_4
e-NIT No.15/ EnM (NW)/ 2020-21
Open Tender
Miscellaneous Works
Item Rate
30 days
MU BLOCK PITAMPURA DELHI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
A/C NO.50448339804
₹19,000
11 Jan 2021
2 Nov 2020
9 Nov 2020
2 Nov 2020
9 Nov 2020
2 Nov 2020
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. DSR 2018 (1.31)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. DSR 2018 (1.32)
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR 2018 (1.12)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. DSR 2018 (1.26)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR 2018 (1.25)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. DSR 2018 (1.44)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. DSR (1.50) 2018
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required, DSR 2018 (1.41)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. DSR 2018 (1.14.2)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, Single pole, DSR 2018 (2.10.1)
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A, DSR 2018(2.12.2)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. DSR 2018 (5.4)
Supply of HSU- 24CK3W3 1.5 Ton Split Air Conditioner Make: - Voltas / O General / Hitachi / Videocon / whirlpool / Samsang / Haier
S/O suitable Stabilizer for split air conditioner
S/O INS. Pipe. For Split A/C
S/O Wall Bracket for split A/C
Installation Charge for split A/C
S/O 190 Ltr refrigerator with five star rating. Make Voltas / Videocon / whirlpool / Samsung
S/O 15 Ltr water geyser with 5 star rating. Make; - Havells / Bajaj / Crompton.
S/O Stainless Steel Electric water cooler Make: - Blue Star/ Voltas / USHA
S/o 20 Watt Stout Plus LED tube light batten fitting make: Havells/ Crompton/ Bajaj/ Philips.
S/O PLUTO PANEL (SURFACE) Aesthetically designed 1x1, 2x2 & 4x1 LED flat panel for surface mounting which provides soft-light and glare free symmetrical illumination. 34 Watt Havells/ Crompton/ Bajaj/ Philips.
S/o ceiling fan, 1200 mm sweep make: Havells / Crompton
Supply of exhaust fan heavy duty 1400 RPM size 450 mm, Make: Havells/ Crompton/ Almonard
S/O Energy saving environmental friendly, long life, exclusive innovative pressure die cast aluminum bay light with high power LED as light source 72/80 watt LED light fitting etc. complete as required for fixing on the wall. Make: Bajaj / Havells / Philips
S/O 40 mm dia G.I. pipe of 1 meter length with 1500 angle band, suitable for fixing of 72/80 watt LED street light along with clamp, Nut & Bolt etc.
Installation Testing & Commissioning of 72/80 watt street light, wiring, connect with MCB with grouting of bolt at walls etc
IPCamera(Bullet)1/3" 2Megapixel PS CMOS Image sensor25/30fps@4M(2688×1520)H.265 and H.264 triple-stream encoding WDR(120dB), Day/Night(ICR), 3DNR, AWB, AGC, BLC3.6mm fixed lens (6mm optional)IR Range of 40 Mtrs, IP67, PoE, SD Card, IVS Features, It should be CE,UL, ISO & FCC certified. Make Hikvision / Samsung / IP Bullet
NVR(Network Video Recorder)4Ch. Network Video Recorder, 4 Ch. with 1080p Real-time Live View, H.265/MJPEG dual codec decoding Up to 5Mp resolution preview & playback Max 80Mbps incoming bandwidth Support 2/4/ SATA HDDs up to HDMI / VGA simultaneous video output Support Multi-brand network cameras ONVIF Version 2.3 conformance.
Surveillance Hard Disk Supported 4TB SATA III Surveillance Hard Disk Backup only for 30 day Backup (8X4TBHDD) Precision-tuned for high write surveillance workloads Reliably performs in multi-drive systems with RAID support
CAT-6 Cable.STP (Approx.)
9U Rack
LED Monitor 19”
Installation & Laying Charges including Fixing of camera
Goodwill Enterprises
ztp corporation
DEV ENGINEERS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .