Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹25.0 L+₹3.5 L (16.5%)Rejected-Finance NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹27.3 L+₹5.9 L (27.4%)Rejected-Finance | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹27.6 L+₹6.2 L (28.7%)Rejected-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L4 | Rejected-Finance Not become lowest bidder | |
| 5 | L5₹29.3 L+₹7.9 L (36.6%)Rejected-Finance | L5 | Rejected-Finance Not become lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
1 Oct 2024, 6:00 pmClosed
CWE JHANSI
HQ CWE JHANSI
REPAIR MAINT OF CERTAIN E/M WORKS AT MIL STN NOWGONG UNDER AGE E/M AT GE JHANSI
2024_MES_672396_1
CWE/JHA/J/TOKEN/30 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
JHANSI
As per tender documents
9 documents required · 9 mandatory
₹500
GE JHANSI
₹60,000
Yes
12 Dec 2024
5 Sept 2024
3 Oct 2024
5 Sept 2024
1 Oct 2024
26 Sept 2024
Amount
Re-filling / Topping up of new transformer oil into the body / conservator tank of transformer to the desired level complete all as specified and directed. Make: Power Oil / Electrol / Transol (Savita) / Servo ELectra. Note: The dielectric strength of oil should not be less than 40 KV.
Supply and fix in replacement of HV side porcelain transformer bushing with brass stud, nuts, bolts & washers including oil seal and gaskets suitable for following rating of step down transformers complete all as specified and directed.
Power transformer upto 5 MVA, 33 KV / 11 KV complete all as specified and directed.
Distribution transformer up to 500 KVA, 11/0.433 KV complete all as specified and directed.
Opening the LV side cable box and disconnecting the LT cables and Supply and fix in replacement of oil seal and gasket suitable for LV side bushing of 11KV/433V transformer of rating up to 500 KVA complete all as specified and directed.
M&L for preparation of old painted surfaces of outdoor/indoor type power / distribution transformers and painting with synthetic enamel paint of approved colour using spray painting machine / spay gun through out externally and writing machine number in white colour on black background complete all as specified and directed for following rating of transformers:-
Power transformer upto 5 MVA, 33 KV / 11 KV
Distribution transformer up to 500 KVA, 11/0.433 KV
Disconnecting the defective transformer of any rating from HV side, LV side and earthing connections and carefully shifting the trolley mounted mobile type transformer of capacity 400 KVA from one location to other location within the nowgong cant with the help of tractor or any suitable means of transportation and making all HV, LV and earthing connections and testing complete all as specified and directed.
Supply and fix in replacement of breather assembly complete with new silica gel and fixing accessories suitable for following rating of existing transformers of any make:-
Power transformer upto 5 MVA, 33 KV / 11 KV
Distribution transformer up to 500 KVA, 11/0.433 KV
Supply and replace silica gel into the breathers of power / distribution transformers of any capacity and make complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard / dense soil for laying of cables complete all as specified and directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and spread M-sand in trenches for cushioning of cable/in yard complete all as specified and directed. Note: Punned down thickness only shall be measured for the purpose of payment.
Material & Labour for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines / cables and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below hard standing will be measured and paid under relevant items.
Material & Labour for Power Cables, Aluminum Stranded Conductor of 150 Sqmm 3.5 core XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings and testing on completion all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items.
Material & Labour for Power Cables, Aluminum Stranded Conductor of 95 Sqmm 3.5 core XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings and testing on completion all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items.
Material & Labour for Power Cables, Aluminum Stranded Conductor of 50 Sqmm 3.5 core XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings and testing on completion all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items.
Supply and fix in replacement of 50mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed.
Supply and fix in replacement of MCCB 100A, 25KA, 4 Pole with fixed thermal magnetic release mounted in MCCB sheet steel enclosure including spreader terminals and connecting up with suitable lugs complete all as specified and directed.
Supply and fix in replacement of MCCB, 160 A, 3 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal magnetic release along with busbar spreader terminal plates including taking down existing unserviceable MCCB of any description complete all as specified and directed.
Supply and fix in replacement of MCCB, 250 A, 3 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal magnetic release along with busbar spreader terminal plates including taking down existing unserviceable MCCB of any description complete all as specified and directed.
Material and labour for preparation of old painted surfaces of HT / LT steel poles and painting with one coat of aluminium paint on all steel surfaces such as poles, channels, angles, clamps, nuts, bolts and washers of any description and Zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band / strips (Make: 3M or equivalent) of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from coping of pole and writing the pole number in black colour on yellow background at a suitable place on the pole including applying one coat of snow cem on PCC coping of pole complete all as specified and directed.
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion including taking out of unserviceable earthing set complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
Material and labour for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT baRs @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
M&L for Cable jointing kit for 33 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95/120 sqmm complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95/120 Sqmm complete all as specified and directed.
Unbinding from insulators and restretching ACSR conductor of any size on LT poles with and including binding with 2mm dia aluminium binding wire to insulators, complete all as specified & directed. Note : 1. The cost of binding wire is deemed to be included in quoted rates. 2. The distance between two poles having 4/5/6 conductors will be considered as one span.
Design, fabricate, supply, installation, testing and commissioning of outdoor type cubicle panel board compartmentalized suitable for 3 phase 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory having modern fabrication facilities, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility. Complete panel board shall be applied with power coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 600mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards(02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall not be less than 1250mm x 1250mm x 450mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring complete all as specified and directed. Note : (i) The Contractor shall submit set of all drawings of the L.T. Panel and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing. However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.
M&L for pruning of tree branches up to 2.0 meter clearance all around HT/LT overhead lines and depositing where directed at a distance not less than 50m complete all as specified and directed. Note: The item will be measured in span length between poles. The approx span length is 50m.
Supply and fix in replacement of Stay assembly with 16mm dia stay rod and all accessories as shown in electrical plate No 1 complete all as specified and directed. Note: Loop type insulator, stay clamps, stay wire, excavation and concrete measured separately.
Supply and fix in replacement of Galvanized stay strand, 7/3.15mm including proper tightening to required tension complete all as specified and directed.
Supply and fix in replacement of Loop type insulator, vitreous porcelain, white, brown or green Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundations of pole/ stay assembly complete all as specified and directed.
Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and directed.
M&L point wiring for one light point with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass screws for mounting switches, sockets, fan regulator, etc controlled by one switch complete all as specified and directed. Note : 1. In case cutting & chasing of conduit is encountered with any beam / column/Stone wall, the ISI Marked PVC casing & capping or surface conduit will be used to avoid any damage to the RCC portion. 2. No cutting & chasing shall be done on ceiling surface for laying PVC conduit for ceiling fan point wiring etc, hence the PVC casing & capping or surface conduit will be used for the same. 3. In place of terminal box on stone wall, PVC gang box/rectangular box for mounting switches/sockets/regulators with back and front cover will be used.
All as per item No 35 above but for Lamp holder point controlled by one 6 Amp switch one way complete all as specified and directed.
All as per item No 35 above but for one ceiling fan/exhaust fan controlled by one 6 Amp switch one way complete all as specified and directed.
All as per item No 35 above but for one Switch socket 6 Amps, 2-in-1 on same board complete all as specified and directed.
All as per item No 35 above but for one 6 Amps, 2-in-1 switch socket out let flush type on the independent board complete all as specified and directed.
All as per item No 35 above but with 2.5 Sqmm copper conductor cable along with one run of 2.5 Sqmm copper conductor cable green in colour for continuous earthing for One 16Amps socket point on the independent board controlled by one switch complete all as specified and directed.
All as per item No 35 above but with 4 sq mm FRLS copper wire with 4 Sqmm FRLS copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board complete all as specified and directed.
Supply and fix in replacement ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement socket 6 Amps, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed.
S&F, in repalcement, of Switch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed.
S&F, in repalcement, of Socket, 6 pin, 16 Amp, , 240 volts, complete all as specified and directed.
S&F, in repalcement of angle/batten type Lamp holder, metal cased, bakelite body, 240 volts, complete all as specified and directed.
S&F of 9 W White LED retrofit lamp B-22 holder base with polycarbonate diffuser and heat sink, complete all as specified and directed.
Supply and fix electronic fan regulator rotary type in 5 steps, 240V, 50Hz complete all as specified and directed.
Supply and fix MCCB / MCB distribution board, Vertical TPN, 4 way with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: (i) MCCB / MCBs shall be measured and paid separately. (ii) In case cutting & chasing is encountered with any beam / column/Stone wall, the DBs may be installed on stone wall only as directed by Engineer-in-charge.
Supply and fix in replacement MCB distribution board, SPN, 8 way in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Notte: (i) MCBs shall be measured and paid separately. (ii) In case cutting & chasing is encountered with any beam / column/Stone wall, the DBs may be installed on stone wall only as directed by Engineer-in-charge.
Supply and fix in replacement MCB distribution board, TPN 4Way in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: (i) MCBs shall be measured and paid separately. (ii) In case cutting & chasing is encountered with any beam / column/Stone wall, the DBs may be installed on stone wall only as directed by Engineer-in-charge.
Supply and fix MCCB 100A, 16 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release including cable connection withcomplete all as specified and directed.
S&F in replacement MCB TPN 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
S&F in replacement MCB TP 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
S&F in replacement MCB SPN 40 amps 240 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
S&F in replacement MCB SP 06 to 32 amps 240 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.
Supply and fix LED batten with CRCA sheet steel body box type pre-wired suitable for and including provision of 1x20 Watt (4 feet) retrofit LED tube with PC body, full white and connecting up with twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
Supply and fix Exhaust Fan 300mm sweep, 900 RPM, metal body with louvers suitable for working on 230V, 50 Hz, Single phase AC supply complete all as specified and as directed.
Supply and fix Exhaust Fan 450mm sweep, 900 RPM, metal body with louvers suitable for working on 230V, 50 Hz, Single phase AC supply complete all as specified and as directed.
Taking down ceiling fan from any position sealing cable end, dismantling blades and depositing fan and blade to E/M Store complete all as specified and directed.
S&F ceiling fan 1200mm sweap size, with and incl ceiling clamp, rubber real, set of 03 blades, 02 nos canopy, metal body, double bearing and making all necessary elect connection complete all as specified and directed.
S&F in replacement down rod in any position/at any height suitable for hanging ceiling fans of 1200/1400 mm sweep made up of medium grade GI pipe 15 mm dia any length as per site requirement and making hole and cut in rod complete all as specified and directed.
Supply and fix in replacement LED street/security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 40mm dia light grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.
Taking down existing sub main wiring of aluminium / copper of 4/6/10sqmm size incl all accessories complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering etc, complete all as specified and directed.
M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed for the following sizes:- Note: (i) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length (ii) Five runs of copper cable and one run of PVC conduit shall be measured as one unit length (iii) In case cutting & chasing of conduit is encountered with any beam / column/Stone wall, the PVC casing & capping or surface conduit will be used to avoid any damage to the RCC portion as directed.
2x6 Sqmm + 1x6 Sqmm
2x4 Sqmm + 1x4 Sqmm
4x6 Sqmm + 1x6Sqmm
M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed.
Supply and fix in replacement of fan capacitor 2.5 mfd, 440V suitable for ceiling fan complete all as specified and directed.
Taking down Ceiling fan of any size carefully, dismantling blades and Cutting and removing of old burnt/damaged winding, cleaning of slots and other parts and rewinding the ceiling fan motor with super enameled copper winding wire of existing gauge with suitable class of insulation, applying varnish, heating, drying, assembling, including replacement of bush/bearings, rubber seal, ms split pin, down rod, and testing for satisfactory performance and refixing after repair in its existing or new location and connecting up including provision of cable from ceiling rose or connector to ceiling fan and testing for satisfactory functioning complete all as specified and directed.
All as per item No 69 above but for exhaust fan/desert cooler motor of any size complete all as specified and directed.
Taking down carefully the electric storage type water heater of capacity up to 50 ltrs from its installed position by disconnecting all water and electric supply connections for necessary repairs, opening the geyser carefully, identifying and replacing the defective parts, reassembling and reinstalling in its existing location or new location and testing for proper functioning complete all as specified and directed. Note: The spare parts required shall be measured and paid separately under relevant items as "Supply Only".
Supply only copper heating element 1500 Watts / 2000 Watts of any type suitable for existing model of geyser 25L/50L complete all as specified and directed.
Supply only thermostat of any type suitable for existing model of geyser 25L/50L complete all as specified and directed.
Supply only apparatus plate of any type suitable for existing model of geyser of capacity 25L/50L complete all as specified and directed.
Supply only indicator lamp Red or Green of any type suitable for existing model of geyser of capacity 25L/50L complete all as specified and directed.
Supply and fix in replacement of flexible PVC connection 450mm long suitable for Hot/Cold water application complete all as specified and directed.
Material and labour for shifting of Split type AC 1.5 / 2.0 TR capacity of any make / model from one location to the other location alongwith stabilizer by carefully taking down the indoor and outdoor unit, copper piping with insulation, drain pipe, wall mount bracket etc and installing the same at new location including testing & commissioning complete all as specified and directed. Note : 1. The cost of making hole for passing through inlet / outlet copper pipes, drain pipe and electrical cable and making good of surface at both location as original by plastering / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect. 2. Extra copper piping if required at new location will be measured and paid separately under respective items.
Supply and fix in replacement of PVC drain pipe 1/2'' size including proper clamping on wall surfaces suitable for 1.5 / 2.0 TR capacity split type AC complete all as specified and directed.
Supply and testing in replacement of remote control unit with batteries suitable for 1.5 / 2.0 TR capacity split type / window type Air conditioners of existing model complete all as specified and directed.
Supply and fix in replacement of copper tube of size 1/4'' to 1/2'' suitable for 1.5 / 2.0 TR capacity split type Air conditioners / walk-in-cooler / Central / package type AC of existing model complete all as specified and directed.
M&L for gas charging of Air Conditioner window / split type / walk-in-cooler of capacity 1.5 / 2.0 TR with R - 22 / R-32 /R-410a or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/brazing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed.
Material and labour for gas charging of refrigerator of capacity up to 310 Liters with R - 22 / R-134A / R-438A / R-600A or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/bracing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed.
Supply and fix in replacement of following spare parts suitable for refrigerator of capacity up to 310 Liters, single phase, 230 V, 50 HZ, AC of existing model complete all as specified and directed.
Hermetically sealed reciprocating type / rotary type compressor unit including gas charging
Compressor start relay
Overload relay
Copper condenser coil
Thermostat
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in any type of soil for laying of cables complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
Material & Labour for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines / cables and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below hard standing will be measured and paid under relevant items.
Material & Labour for Power Cables, Aluminum Stranded Conductor 16 Sqmm 4 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings / connecting overhead lines with suitable binding wire and testing on completion including taking down existing unserviceable cable of any description complete all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.
Material & Labour for Power Cables, Aluminum Stranded Conductor 16 Sqmm 2 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings / connecting overhead lines with suitable binding wire and testing on completion including taking down existing unserviceable cable of any description complete all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.
Material & Labour for Power Cables, Aluminum Stranded Conductor 10 Sqmm 4 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings / connecting overhead lines with suitable binding wire and testing on completion including taking down existing unserviceable cable of any description complete all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.
Material & Labour for Power Cables, Aluminum Stranded Conductor 10 Sqmm 2 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings / connecting overhead lines with suitable binding wire and testing on completion including taking down existing unserviceable cable of any description complete all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.
Supply and fix in replacement of 50mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure laid in trenches/ floors/ duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed.
Supply and fix in replacement of 120 Watt LED street light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP66 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including taking down of existing unserviceable street light fitting of any description complete all as specified and directed.
Supply and fix in replacement of 60 Watt LED street light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP66 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including taking down of existing unserviceable street light fitting of any description complete all as specified and directed.
Supply and fix in replacement of 35 Watt LED street light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP66 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including taking down of existing unserviceable street light fitting of any description complete all as specified and directed.
Supply and fix Thermoplastic cable junction box IP 66/67 “weather proof”, for outdoor installation (with knockouts for cable entry) of size 220mm x 140mm x 95mm with provision of 63Amps rated four pole (3P+N) connector, one single pole MCB of 6 Amps rating mounted on DIN rail, PVC cable glands of suitable size for incoming and outgoing cables and PVC gland for copper control cable for light fitting including fixing on steel tubular poles / PCC poles with suitable size MS clamps with fixing brackets (02 Nos), nuts, bolts, washers etc duly painted with two coats of aluminium paint over a coat of red oxide primer on steel clamps and brackets in taking down old junction box etc complete all as specified and directed.
Supply and connect in replacement of PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts grade, conforming to IS 694, three core, 2.5 sqmm for connecting from junction box to street light fitting/ connect in any description complete all as specified and directed.
Taking down the defective LED street light fitting/security light fitting of various wattage from 45 to 120 watt from 9m/11m pole etc from any position/height and indentifying the fault and replacing the defective LED driver/replacing the burnt wiring and re-assembling the fittings and re-fixing in its original position and testing for proper functioning complete all as specified and directed. Note :- Supply only of LED driver and supply and replacement of cable shall be measured and paid separately under relevant items of BoQ.
Supply and fixing in replacement of LED driver as per sample suitable for existing make & model of 120 watt LED street light fitting complete all as specified and as directed.
Supply and fixing in replacement of LED driver as per sample suitable for existing make & model of 90 watt LED street light fitting complete all as specified and as directed.
Supply and fixing in replacement of LED driver as per sample suitable for existing make & model of 70 watt LED street light fitting complete all as specified and as directed.
Supply and fixing in replacement of LED driver as per sample suitable for existing make & model of 45 watt LED street light fitting complete all as specified and as directed.
Supply and fix in replacement of LED Post top light fitting 40 Watt / 45 Watt, made in die-cast aluminum housing with decorative clear opal acrylic diffuser, IP 65 protection, spun aluminum powder coated canopy, low power Warm White (WW) LEDs connected in series and parallel combination with better heat dissipation arrangement with LED color temperature- 3000K ±300K, Highly efficient constant current electronic driver having operating voltage range from 140-280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 5KV complete suitable for up to 60mm OD pipe entry with fixing bolts including taking down existing unserviceable post top light of any description complete all as specified and directed.
Supply and fix in replacement of GI pipe bracket made out of 40mm dia medium grade GI pipe of 1.50mtr long bent to required shape and fixed to steel tubular / PCC pole with clamps made out of 40mm x 5 mm MS flat fixed with suitable nuts, bolts and washers etc including taking down existing unserviceable bracket of any description complete all as specified and directed.
Making holes (02 Nos - one near cable junction box and other near street light bracket) on existing steel tubular poles of any type, thickness & height through drilling / gas welding work having smooth and chamber edge of hole, for drawing street light control cable through inside of pole complete all as specified and directed.
Supply and fix in replacement of Post top lantern Black ABS plastic spigot, spun aluminium canopy, with clear acrylic diffuser and accessories along with LED lamp 14 Watt with B22 base lamp holder including taking down existing unserviceable post top lantern fitting of any description complete all as specified and directed.
S&F of LED flood light luminaire of 90 Watt capacity, with toughened glass cover, IP 66 protection and individual high power LEDs with secondary optics having Lumen efficacy of LED ≥140 lm/W, viewing angle of 120° to ensure better uniformity, independent Potted IP67 electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection upto 10 kV with inbuilt SPD & other safety test as per IS 15885 Part-2 / Sec 13, IEC60598-1 complying, duly fixed on High mast of any height and type, with and incl making all electric connection complete all as specified and directed.
S&F of LED flood light luminaire of 150 Watt capacity, with toughened glass cover, IP 66 protection and individual high power LEDs with secondary optics having Lumen efficacy of LED ≥140 lm/W, viewing angle of 120° to ensure better uniformity, independent Potted IP67 electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection upto 10 kV with inbuilt SPD & other safety test as per IS 15885 Part-2 / Sec 13, IEC60598-1 complying, duly fixed on High mast of any height and type, with and incl making all electric connection and taking down of UNSV flood light fitting of any type, complete all as specified and directed.
Taking up or down steel water tubing alongwith fittings and connections of following sizes from any trenches/on walls/ceilings/floors or any description, complete all as specified and directed.
15mm dia size
20mm dia size
25mm dia size
40mm dia size
50mm dia size
80mm dia size
100mm dia size
M&L for GI water tubing of following sizes nominal bore, medium grade, ISI marked, with and including all fittings i.e. bend, tee, elbow, reduce, union etc, laid in trenches, complete all as specified and directed. Make : Jindal / TATA / Prakash Surya / Swasthik Note : 1. The excavation & earthwork shall be measured & paid for separately. 2. The cost of all type of GI fitting i.e. bend, tee, elbow, reduce, union etc is deemed to be included in quoted rates.
25 mm dia size
40 mm dia size
50 mm dia size
80 mm dia size
100 mm dia size
M&L for GI water tubing of following sizes medium grade, ISI marked, with and including all fittings i.e. bend, tee, elbow, reduce, union etc, fixed to wall /floor/ ceiling, complete as specified and directed. Make : Jindal / TATA / Prakash Surya Note : The cost of all type of GI fitting i.e. bend, tee, elbow, reduce, union etc is deemed to be included in quoted rates.
15 mm dia size
20 mm dia size
25 mm dia size
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for laying of pipes and getting out in any type of soil, complete all as specified and directed.
Returning filling in with and including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in any type of soil, complete all as specified and directed.
Removal of excavated soil / material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point, complete all as specified and directed.
S&F in replacement of Gun metal globe or Gate valves of Following sizes with ironwheel head, screwed both ends for iron pipe including taking out unserviceable valve, complete all as specified and directed. Make - Prayag / Leader / Prince / Sant Valves
50 mm dia nominal bore
40mm dia nominal bore.
25mm dia nominal bore.
20mm dia nominal bore.
15mm dia nominal bore.
Cleaning the internal portion of RCC overhead reservoir of capacity 1,00,000 Liters having staging height up to 20 meters by applying wire brush on walls and bottom of tank and removing the silt/sand/ fungus etc deposited inside the tank by opening wash out valve, followed by cleaning with bleaching water solution and fresh water and finally applying one coat of white wash on internal surfaces including writing the date of cleaning and due date of cleaning in white colour on black background on external wall complete all as specified and directed.
Cleaning the internal portion of RCC underground / semi underground sump of capacity 50,000 Liters by applying wire brush on walls and bottom of tank and removing the silt/sand/ fungus etc deposited inside the sump with buckets and depositing where directed, followed by cleaning with bleaching water solution and fresh water and finally applying one coat of white wash on internal surfaces including writing the date of cleaning and due date of cleaning in white colour on black background on external wall complete all as specified and directed.
Cleaning of water well of dia 40 ft and depth 60 ft by taking out water, mud, sludge, dust particles by the help of non clogging pumping set etc. from bottom of well and thrown out as directed, scraping inner surface by the help of steel wire brush and treating surface with bleaching powder complete with and incl 02 coat of white washing including writing the date of cleaning complete all as specified and directed. Note : Damage/risk to human life during cleaning is contractor's responsibility and no claim on this account will be admissible.
Disconnecting the electric cable and water mains, lifting the submersible pump set of capacity up to 25 HP along with column pipe and submersible cable from bore well having depth up to 150 meters for carrying out repairs / rewinding / replacement of defective submersible cable / replacement of rusted column pipe / etc and re-installing and reconnecting the water mains and electric connections and testing for satisfactory performance complete all as directed. Note: Repairs, rewinding, submersible cable, shifting of submersible pump to civil work shop etc shall be measured and paid separately under relevant items of Sch 'A'.
Shifting of pump set with motor of any type and any capacity from any pump house / open well / bore well to civil workshop for repair / rewinding and bringing back with suitable mode of transport complete all as specified and directed.
Cutting and removing burnt out winding from submersible electric motor of any make of capacity up to 12.5 HP and rewinding with water proof poly wrapped copper winding wires of existing gauge and number of turns and testing for satisfactory performance complete all as specified and directed.
Cutting and removing burnt out winding from submersible electric motor of any make of capacity 17.5 to 25 HP and rewinding with water proof poly wrapped copper winding wires of existing gauge and number of turns and testing for satisfactory performance complete all as specified and directed.
Overhauling of pump set of any make by opening the pump and motor, replacing the worn out/defective spare parts, making good of shaft and shaft sleeve, cleaning internally, lubricating the rotating parts, reassembling the pump and motor duly replacing the all the packing material, worn out bolts, nuts, washers etc and testing for satisfactory performance complete all as directed and directed for the submersible pump set of capacity up to 25 HP. Note: (i) Quoted rate shall deemed to be inclusive of necessary packing material, nuts, bolts & washers etc. (ii) Spare parts replaced shall be measured and paid separately under relevant items of Sch 'A' as supply only.
Supply only the following spare parts suitable for submersible / open well submersible pump sets and motors :-
Ball bearing suitable for up to 25 HP pump set
Impeller suitable for submersible pump up to 25 HP pump set
Strainer suitable for submersible pump up to 25 HP pump set
Coupling assembly suitable for submersible pump up to 25 HP pump set
Sand guard suitable for submersible motor up to 25 HP pump set
Oil seal suitable for submersible motor up to 25 HP pump set
Thrust bearing suitable for submersible motor up to 25 HP pump set
S&F in replacement of cast iron non return valves of following size,having pressure rating PN 1.0, ISI marked with gun metal sheet and flap , both ends fanged, with and incl all jointing material i.e. new rubber gaskets, nuts, bolts, washers etc of required size with and incl taking down old unserviceable valve, complete all as specified and directed. Make : L&T Valve / Leader Valve / Kirloskar Valve.
80 mm dia nominal bore.
100mm dia nominal bore.
M/S Ritu Tandon (BID ID -3123925)
M/s Raghav Traders (BID ID -3123471)
SHRI HARI CONSTRUCTION (BID ID -3123344)
m/s gupta trading (BID ID -3122825)
m/s bobby enterprises (BID ID -3123540)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .