Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹35.7 L+₹6.3 L (21.5%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹37.9 L+₹8.5 L (28.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹39.3 L+₹9.9 L (33.8%)Rejected-Finance 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹42.6 L+₹13.2 L (44.9%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
5 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AFEM Chakeri Kanpur
GE(AFEM Chakeri Kanpur
REPAIR / MAINT OF SERVO CONTROLLED VOLTAGE STABILIZERS OF VARIOUS CAPACITY AND CAPACITOR BANKS INSTALLED AT VARIOUS LOCATIONS AT AFS KANPUR
2023_MES_626540_1
8653/E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AFEM Chakeri Kanpur
As per tender document
9 documents required · 9 mandatory
₹500
GE(AFEM Chakeri
₹76,000
Yes
3 Feb 2024
3 Nov 2023
11 Dec 2023
4 Nov 2023
5 Dec 2023
21 Nov 2023
Amount
Disconnecting of LT supply from APFC panel any type and size and maintenance & servicing of complete capacitor bank panel of any capacity including cleaning of all contacts, decarbonising of contactor contacts with petrol/CRC, checking & tightening of all cable/ bus bar connection, CT connections & replacement of worn out parts such as capacitors, capacitor lugs, MOC, CT's, indicators, Rotary switches, APFC relays, fuses & measuring meters etc including setting of power factor 0.98 to 0.99 and testing after repair complete all as specified and directed. Note- Spare Parts replaced of APFC panel shall be measured and paid separately.
M & L in replacement of MPP heavy duty capacitor bank cylindrical type, 3 phase 440 volts of capacity 1 KVAR including necessary copper lead copper lugs of suitable size complete all as specified and directed. Make : L&T / Schnieder / BCH / EPCOS
All as per Item No 2 above but capacity 3 KVAR
All as per Item No 2 above but capacity 5 KVAR
All as per Item No 2 above but capacity 7.5 KVAR
All as per Item No 2 above but capacity 10 KVAR
All as per Item No 2 above but capacity 12.5 KVAR
All as per Item No 2 above but capacity 15 KVAR
All as per Item No 2 above but capacity 20 KVAR
All as per Item No 2 above but capacity 25 KVAR
All as per Item No 2 above but capacity 50 KVAR
All as per Item No 2 above but capacity 100 KVAR
All as per Item No 2 above but capacity 200 KVAR
S & F in replacement of 3 pole Capacitor duty Contactor type MOC suitable for upto 5 KVAR capacitor comprising of built-in-auxiliary contacts, 50 Hz AC rating 415 volts in existing LT panel complete all as specified and directed. Make : L&T / Siemens / Schnieder
All as per Item No 14 above but for upto12.5 KVAR capacitor.
All as per Item No 14 above but for upto 20 KVAR capacitor.
All as per Item No 14 above but for 25 KVAR capacitor.
All as per Item No 14 above but for 50 KVAR capacitor.
All as per Item No 14 above but for 100 KVAR capacitor.
All as per Item No 14 above but for 200 KVAR capacitor.
S & F in replacement of power factor controller relay of 7 steps suitable for operation at 415 V power and auxiliary both 5 amp as current measurement. The relay shall improve the PF by at least 0.98. The relay shall be microprocessor based with self diagnostic and setting complete all as specified and directed. Make : L& T / Siemens / Schnieder
All as per Item No 21 above but relay 8 steps
All as per Item No 21 above but relay 12 steps
S & F in replacement switch disconnector fuse with HRC fuse 100 Amps 4 pole 415 V ,panel mouting type without enclosure,including labour for alterration in panel etc complete all as specified and directed. Make : L&T / Schnieder / C&S
All as per Item No 24 above but of rating 250 Amps
All as per Item No 24 above but of rating 400 Amps
S & F in replacement digital ammeter flush type 96X96 Sqmm,3 Phase, 5A, Class1 in existing LT panel with suitable fixing arrangement and repair to wiring as required complete all as specified and directed. Make : L&T / HPL / AE / Conserve
S & F in replacement digital volt meter flush type 96X96 Sqmm, 0-500 volts,3 Phase,Class I in existing LT panel with suitable fixing and repair to wiring as required at site complete all as specified and directed. Make : L&T / HPL / AE / Conserve
S & F in replacement of indicator lamp LED type (R,Y,B in colour) suitable 110/220 volts AC or 30 volt DC for in existing LT panel with suitable wiring as required at site complete all as specified and directed. Make : L&T / HPL / AE / Conserve
S & F in replacement LT RG tape wounded current transformer in existing panel in replacement 300/5, 10 VA with suitable wiring complete all as specified and directed. Make: L&T / HPL / AE / Conserve
S & F in replacement LT RG tape wounded current transformer in existing panel in replacement 500/5, 15 VA with suitable wiring complete all as specified and directed. Make : L&T / AE / Kappa
Material & Labour in replacement of copper wire for control circuit in capacitor bank of size 2 core 2.5 sqmm 1100 volts grade complete all as specified and directed.
Material & Labour in replacement of copper wire for control circuit in capacitor bank of size 2 core 4 sqmm 1100 volts grade complete all as specified and directed.
S & F in replacement MCB SP 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. Make : Legrand / Indo Asian / L&T / Schneider / Havells
All as per Item No. 35 above but SPN of rating 16-32 Amps
All as per Item No. 35 above but TPN of rating 40-63 Amps
S & F in replacement digital multifunctional meter flush type 3 Phase, Class I in existing LT panel with suitable fixing and repair to wiring as required at site complete all as specified and directed. Make : L&T / HPL / AE / Conserve
S & F in replacement digital PF meter flush type 96X96 Sqmm, fixed in existing LT panel with suitable wiring and repair as required at site complete all as specified and directed. Make : L&T / HPL / AE / Conserve
M & L for repair & welding of LT feeder pillar box / APFC panel front / rear door and locking arrengement with lock & key including minor parts such as hinges, screw, nuts & bolts, gaskets etc including paint patch work making good as per existing colour and complete all as specified and directed.
Supply & fix in replacement of front and rear door of LT feeder pillar box according to existing feeder pillar box size made up of 3.15 mm thick MS sheet with two coat of existing feeder pillar box colour paint over one coat of red oxide primer complete all as specified and directed.
M & L for scrapping, cleaning, and preparation of old painted surface of LT feeder pillar box / APFC panel out door / indoor type of surface and painting with one coat of red oxide primer and two coats of synthetic enamel paint by spray gun complete all as specified and directed.
S & F in replacement Electronic Thyristor Module of each APFC PANEL 3 pole / 4 pole AC of capcity having coil voltage 250 volt 05 -10 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed.
All as per Item No 43 above but of capacity 12.5 - 20 KVAR
All as per Item No 43 above but of capacity 25 - 50 KVAR
All as per Item No 43 above but of capacity 100 - 200 KVAR
Preventive Maintenance and Servicing of Voltage Stabilizer, Air / Oil Cooled & Indoor / Outdoor type of 5 to 20 KVA capacity by disconnecting carefully its electric cable connection on primary & secondary side, checking both side bushing, bus bar connections, opening top cover of the Voltage Stabilizer by unscrewing its nuts, bolts, washers etc, rectify the electrical issues, if any, during servicing and re-fixing the top cover of voltage stabilizer according to previous system. Servicing of the Servo Voltage Stabilizer must be done through OEM or authorised personnel. (a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts etc. (b) Checking all brazings, joints, tap heads, gaskets and connection joints etc. (c) Checking all terminations / connections inside Voltage Stabilizer. (d) Checking moving / fixed contacts for contact wear and connection to winding etc. Note : - All defective parts including cable & oil to be replaced will be measured & paid separately.
All as per Item No 47 above but of capacity 25 KVA - 75 KVA
All as per Item No 47 above but of capacity 100 KVA - 300 KVA
All as per Item No 47 above but of capacity 400 KVA - 1000 KVA
S & F in replacement servo motor for instant start & stop, high torque input voltage 440 V, 3 phase, 50 Hz, 1500 RPM as per existing make and size for stabilizer of capacity 75 KVA complete all as specified and directed.
All as per Item No 51 above but of capacity 100 KVA
All as per Item No 51 above but of capacity 150 KVA
All as per Item No 51 above but of capacity 200 KVA
All as per Item No 51 above but of capacity 300 KVA
All as per Item No 51 above but of capacity 500 KVA
S & F in replacement of control relay of existing size and rating for over load / short circuit protection / high low voltage cut off / spike and surge protection / single phase protection for stabilizer of capacity 5 - 20 KVA complete all as specified and directed.
All as per Item No 57 above but of capacity 25 - 75 KVA
All as per Item No 57 above but of capacity 100 - 200 KVA
All as per Item No 57 above but of capacity 300 - 650 KVA
S & F in replacement of aluminum brush assembly for stabilizers complete all as specified and directed.
S & F in replacement of terminal strip for stabilizers complete all as specified and directed.
S & F in replacement of variable voltage wound coil for stabilizer of capacity 75 -100 KVA complete all as specified and directed.
All as per Item No 63 above but of capacity 150 - 200 KVA
All as per Item No 63 above but of capacity 300 - 650 KVA
S & F in replacement of control transformer of suitable rating for stabilizer of capacity 75 -200 KVA complete all as specified and directed.
All as per Item No 66 above but of capacity 300 - 650 KVA
S & F in replacement of PCB control card / Sensing control card digital microprocessor based for stabilizer of capacity 75 -100 KVA complete all as specified and directed.
All as per Item No 68 above but of capacity 150 - 200 KVA
All as per Item No 68 above but of capacity 300 - 650 KVA
Rectifying and arresting the oil leakage of stabilizer of any capacity, disconnection, removing of all fitments, replacing the components of the stabilizer such as gasket etc. , rectify the leaks in a variety of areas such as fins, flanges, valves, fastener assemblies, oil leakage through pin hole/ crack joint, drain valve, oil leakages through gasket joint etc complete all as specified and directed .
M & L for dismantling of stabilizers of capacity 25 KVA to 125 KVA indoor/outdoor type complete by opening cover by unscrewing nuts, bolts, gaskets, draining out oil and keeping safely for reuse after filtration, cleaning the inner body with caustic soda/detergent and washing to removing sludge etc, painting the inner side tank by Zinc chromate paint and preparing the same for reassembling complete all as specified and directed
All as per Item No 72 above but of capacity 150 - 200 KVA
All as per Item No 72 above but of capacity 300 - 650 KVA
M & L for topping up of oil in voltage stabilizer upto capacity 125 KVA at site having dielectric strength 40 - 60 KV during filling after initial filtration conforming to IS-335. Oil shall be supplied in sealed container complete all as specified and directed. Make :-Poweroil / HP / BPL / IOCL / SAVITA (Note:- (i) Before topping up transformer oil sealed container shall be got checked at MES store yard (ii) Breakup details of topping of oil as per capacity of voltage stablizer shall be entered in MB ).
All as per Item No 75 above but of capacity 150 - 250 KVA
All as per Item No 75 above but of capacity 300 - 650 KVA
Dehydration/ filtration of transformer oil of existing stabilizer installed at site with portable plant to improve the dielectric strength 50 to 70 KV including top up transformer oil upto the level complete all as specified and directed. Note:- (i) Conducting field testing of di-electric strength and acidity test of Tr. Oil to be carried out with acidity test kit before and after filtration. (ii) Transformer oil required for top up shall be measured and paid separately. (iii) The Contractor shall arrange his own the electric power required for testing/ de-hydration as and when required.
M & L for painting of stabilizer of for capacity 15 KVA to 25 KVA indoor/ outdoor type with one coat of red oxide primer and two coats of synthetic enamel paint with compressor spray Gun after removing all dust, rust etc. and writing description with white paint on location complete all as specified and directed
All as per item No 79 above but of capacity 50 to 150 KVA
All as per item No 79 above but of capacity 200 to 650 KVA
M & L for shifting of Stabilizer / LT panel etc from one location to another location from existing PCC platform and fixing on platform structure by suitable capacity of crane including necessary disconnection and connection and testing on completion complete all as specified and directed.
Dismantling and segregation of burnt and damaged copper coil from stabilizer upto capacity 250 KVA and making new coil with insulated copper wire of required gauge craft paper cotton tape insulation as per specification of old stabilizer including opening & heating before assembling the winding core and necessary testing as required including taking out unserviceable winding complete all as specified and directed.
All as per item No 83 above but of capacity 300 to 650 KVA
S & F in replacement control wiring of 1.5 Sqmm single core multi-stranded FRLS copper conductor insulated with heat shrinkable PVC sleeve tagged and secured for indicators / meters/Voltage Stabilizers etc including suitable size of copper lugs, PVC cable ducts, galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
Supply and fixing in replacement of gun metal gate valve , ISI marked suitable for oil inlet / outlet valves of voltage stabilizer complete all as specified and directed of bore dia 25-32 mm
All as per item No 86 above but of bore dia 40-50 mm
SUSHMANAND ENGINEERING WORKS
DUBEY TRADERS & eNGINEERS
A.B.Enterprises
Bharat Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .