Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAdmitted-Finance | ₹1.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.8 Cr+₹10.8 L (6.57%)Admitted-Finance S 191 C FIRTS FLOOR SCHOOL BLOCK SHAKARPUR EAST DELHI DELHI EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | ₹1.8 Cr+₹10.8 L (6.57%) | L2 | Admitted-Finance |
| 3 | L3₹1.9 Cr+₹27.3 L (16.6%)Admitted-Finance | ₹1.9 Cr+₹27.3 L (16.6%) | L3 | Admitted-Finance |
| 4 | L4₹2.1 Cr+₹49.6 L (30.0%)Admitted-Finance OFFICE NO 301 KANCHAN ONYX COMPLEX UNDRI PISOLI ROAD S NO 9 PART PUNE MAHARASHTRA 411048 | PUNE | MAHARASHTRA | 411048 | ₹2.1 Cr+₹49.6 L (30.0%) | L4 | Admitted-Finance |
| 5 | L5₹2.5 Cr+₹88.6 L (53.7%)Admitted-Finance 3RD FLOOR PLOT NO 59 SY NO 41 AARADHYA GRANDEUR KAVURI HILLS MADHAPUR HYDERABAD TELANGANA 500033 | HYDERABAD | TELANGANA | 500033 | ₹2.5 Cr+₹88.6 L (53.7%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S. Safe N Secure Fire Systems L4 | GRID2CHIP L1 | INTERACTIVE DATA SYSTEMS LIMITED L5 | FACT SYSTEMS L3 | M/S SHIVA ENGINEERING AND TECHNOLOGIES PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Section: I) ADDRESSABLE FIRE ALARM SYSTEM
Fire Alarm Control Panel (FACP): Supplying installation testing and commissioning of Analogue addressable micro Processor - controlled, Standalone, Main Fire Alarm Control Panel 2 loop (1 Loop Card) (with minimum 125 detectors /125 devices capacity per loop card ) with LCD display, capable of being networked to the central monitoring System, to monitor and integrate other panels such as Access control System and accessories like detectors, LCP's, hooters, control modules, monitor modules, Fault Isolation Modules, response indicators, fire/ fault indicators, audio-visual signals, central processing units, complete with LCD display, zone indicating LEDs, having multiple access levels, event history file in non-volatile memory (EEPROM) as per the detailed specification, complete with PSU, Battery backup along with charger for 48 hours in non-alarm condition and 30 minutes in alarm condition etc. as required for each panel. The panel shall be UL listed fire alarm panel. | 3 | Each | 76,000 ₹2,28,000 Lowest | 1,20,721 ₹3,62,163 | 3,93,600 ₹11,80,800 | 2,65,000 ₹7,95,000 | 2,09,475 ₹6,28,425 |
| 2.10 | Addressable MultiSensor Detector: Supply of Addressable analogue MULTISENSOR / MULTICRITERIA type, UL Listed photo cum thermal detectors with solid state design, indicating LED, mounting base, mounting bracket etc. base box, loop in and loop out gland as per requirement and detailed specification. As per following position:
a) On Real Ceiling (Base Box is to be Used) /false flooring (Base Box with bracket is to be Used) | 161 | Each | 2,680 ₹4,31,480 | 2,223 ₹3,57,903 Lowest | 3,100 ₹4,99,100 | 2,550 ₹4,10,550 | 2,755 ₹4,43,555 |
| 2.20 | b) On False Ceiling | 58 | Each | 2,680 ₹1,55,440 | 2,223 ₹1,28,934 Lowest | 3,000 ₹1,74,000 | 2,550 ₹1,47,900 | 2,755 ₹1,59,790 |
| 3.00 | Addressable control modules: Supplying, installation, testing and commissioning of UL Listed Addressable control module complete with junction box etc. for control options for Hooters & for other control options like PA evacuation, Access Doors opening, the package Air Conditioners trip etc., in case of emergency, as required. | 20 | Each | 3,750 ₹75,000 | 4,174 ₹83,480 | 3,060 ₹61,200 | 2,650 ₹53,000 Lowest | 3,800 ₹76,000 |
| 4.00 | Addressable monitoring modules: Supplying, installation, testing and commissioning of UL Listed Addressable monitoring modules complete with junction box etc., to monitor status of other systems etc. as required. | 8 | Each | 3,520 ₹28,160 | 3,296 ₹26,368 | 3,200 ₹25,600 | 2,650 ₹21,200 Lowest | 3,800 ₹30,400 |
| 5.00 | Manual Call Point:Supplying installation testing and commissioning of UL Listed Manual call points with NO/ NC contacts slim type with Pull type/ break glass with Reset Lock & Key arrangement suitable for addressable function | 14 | Each | 4,280 ₹59,920 | 4,926 ₹68,964 | 3,715 ₹52,010 | 3,100 ₹43,400 Lowest | 3,895 ₹54,530 |
| 6.00 | Electronic Hooter Cum Strobe: Supplying, installation, testing and commissioning of Hooter having three distinct sounds with addressable relay module and strobe light with minimum 85 db from 1Mtr distance, UL listed etc. as required. | 11 | Each | 5,580 ₹61,380 | 5,463 ₹60,093 | 4,435 ₹48,785 | 2,950 ₹32,450 Lowest | 9,025 ₹99,275 |
| 7.00 | Fault Isolator Module: Supplying, installation, testing and commissioning of UL Listed Fault isolation module to electrically isolate different sections of detector loops (for every 20 detectors/ devices) as per detailed specifications.etc., as required. | 10 | Each | 2,550 ₹25,500 | 3,296 ₹32,960 | 3,060 ₹30,600 | 2,950 ₹29,500 | 247 ₹2,470 Lowest |
| 8.00 | Response Indicator: Supplying, installation, testing and commissioning of Response indicator having twin LEDs for mounting on false ceiling / wall at the entries of the cabin for indicating the operation of detectors in the above false ceiling / below false flooring detectors etc., as required. | 161 | Each | 150 ₹24,150 Lowest | 236 ₹37,996 | 310 ₹49,910 | 170 ₹27,370 | 865 ₹1,39,265 |
| 9.00 | Supplying and laying of 2 core x 1.5 sqmm armoured FRLS copper cable on surface/recess suitable for operation on 240V, 50Hz AC supplying including interconnections, testing etc., as reqd. | 3,250 | mtr | 150 ₹4,87,500 | 130 ₹4,22,500 | 150 ₹4,87,500 | 110 ₹3,57,500 Lowest | 209 ₹6,79,250 |
Tender Value
₹2.3 Cr
EMD Value
₹4.6 L
Closing Date
30 Jun 2023, 3:00 pmClosed
EXECUTIVE ENGINEER
602, 6th Floor, BSNL Bhavan Adarshnagar, Hyderabad-500063
Rate Contract for SITC of Addressable Fire Alarm, Fire Suppression and Aspirating Smoke Detection System for Main and DR Core DC and NMS sites under Project IX.2 at Various locations of BSNL.
2023_BSNL_157081_1
25/BEDH-II/2023-24
Open Tender
Electrical Works
Item Rate
180 days
HYDERABAD KOLKATTA BHUBANESHWAR
Please refer Tender documents.
14 documents required · 14 mandatory
₹1,770
AO CASH MAIN BSNL HYDERABAD
₹4.6 L
23 Jan 2024
12 Jun 2023
1 Jul 2023
12 Jun 2023
30 Jun 2023
12 Jun 2023
Amount
Section: I) ADDRESSABLE FIRE ALARM SYSTEM Fire Alarm Control Panel (FACP): Supplying installation testing and commissioning of Analogue addressable micro Processor - controlled, Standalone, Main Fire Alarm Control Panel 2 loop (1 Loop Card) (with minimum 125 detectors /125 devices capacity per loop card ) with LCD display, capable of being networked to the central monitoring System, to monitor and integrate other panels such as Access control System and accessories like detectors, LCP's, hooters, control modules, monitor modules, Fault Isolation Modules, response indicators, fire/ fault indicators, audio-visual signals, central processing units, complete with LCD display, zone indicating LEDs, having multiple access levels, event history file in non-volatile memory (EEPROM) as per the detailed specification, complete with PSU, Battery backup along with charger for 48 hours in non-alarm condition and 30 minutes in alarm condition etc. as required for each panel. The panel shall be UL listed fire alarm panel.
Addressable MultiSensor Detector: Supply of Addressable analogue MULTISENSOR / MULTICRITERIA type, UL Listed photo cum thermal detectors with solid state design, indicating LED, mounting base, mounting bracket etc. base box, loop in and loop out gland as per requirement and detailed specification. As per following position: a) On Real Ceiling (Base Box is to be Used) /false flooring (Base Box with bracket is to be Used)
b) On False Ceiling
Addressable control modules: Supplying, installation, testing and commissioning of UL Listed Addressable control module complete with junction box etc. for control options for Hooters & for other control options like PA evacuation, Access Doors opening, the package Air Conditioners trip etc., in case of emergency, as required.
Addressable monitoring modules: Supplying, installation, testing and commissioning of UL Listed Addressable monitoring modules complete with junction box etc., to monitor status of other systems etc. as required.
Manual Call Point:Supplying installation testing and commissioning of UL Listed Manual call points with NO/ NC contacts slim type with Pull type/ break glass with Reset Lock & Key arrangement suitable for addressable function
Electronic Hooter Cum Strobe: Supplying, installation, testing and commissioning of Hooter having three distinct sounds with addressable relay module and strobe light with minimum 85 db from 1Mtr distance, UL listed etc. as required.
Fault Isolator Module: Supplying, installation, testing and commissioning of UL Listed Fault isolation module to electrically isolate different sections of detector loops (for every 20 detectors/ devices) as per detailed specifications.etc., as required.
Response Indicator: Supplying, installation, testing and commissioning of Response indicator having twin LEDs for mounting on false ceiling / wall at the entries of the cabin for indicating the operation of detectors in the above false ceiling / below false flooring detectors etc., as required.
Supplying and laying of 2 core x 1.5 sqmm armoured FRLS copper cable on surface/recess suitable for operation on 240V, 50Hz AC supplying including interconnections, testing etc., as reqd.
Section: II) FIRE SUPPRESSION SYSTEM Designing and Supplying installation testing and commissioning of Vds/UL approved NOVEC 1230 fire suppression system, design for highest degree of protection and minimum extinguishing time for Server Room at uniform extinguishing concentration comprising of following components and related accessories, connections etc. as required. a) Supplying, installation, testing and commissioning of 120 Ltrs capacity seamless cylinder suitable for filling NOVEC 1230 complete with Cylinder Valve, Pressure gauge, safety outlet and port for low pressure switch connection and cylinder strap complete as required. Note: cylinder pressure, in compliance with Chief Controller of Explosive, Nagpur with electric & pressure operated control heads as per requirement complete with Master Actuation kit and other required accessories to make the cylinder completely operational etc complete as required.
b) Supplying and charging of NOVEC 1230 Agent in the existing cylinders.
c) Supplying installation testing and commissioning of Electrical Actuator with local manual actuator
d) Supplying installation testing and commissioning of Pneumatic actuator with all accessories
e) Supplying, installation, testing and commissioning of High pressure discharge flexible hose with fittings
f) Supplying, installation, testing and commissioning of Flexible actuation hose
g) Supplying, installation, testing and commissioning of Manifold
h) Supplying, installation, testing and commissioning of bracket for mounting the cyinders
i) Supplying, installation, testing and commissioning of NOVEC 1230 discharge brass nozzle
j) Supplying, installation, testing and commissioning of Non Return Valve
k) Supplying, installation, testing and commissioning of manual release switch (UL listed)
l) Supplying, installation, testing and commissioning of manual abort switch (UL listed)
Supplying, installation, testing and commissioning of suitable size M. S. Seamless pipes as per ASTM 106 Gr. B, Schedule-40 according to design consideration complete with necessary fittings including cutting, welding and clamping and shall be painted with two coats of primer and two coats of red enamelled paint as per fire norms etc., complete as required for the following areas. a) Hyderabad (Area appox 375sqmtr)
b) Kokata (Area appox 265sqmtr)
c) Odisha (Area appox 240sqmtr)
Supplying, installation, testing and commissioning of Two Zone Addressable Gas Release Panel facility to connect the Manual Abort/Release switches. The Panel shall provide potential free contacts for first knock, second knock, trouble/fault status. The Panel shall be complete with red colour housing, power supply unit, battery charger, batter etc., as reqd.
Section: III) Aspirating Smoke Detection System Aspirating Smoke Detector: Supply, installation, testing and commissining of Single channel Fire Alarm Aspiration system with coverage up to 500sqm and sensitivity range 0.00029% obs/ft to 6.25Obs/Ft, ultrasonic flow sensing and chamber air flow monitoring for presise system healthy information, dual source optical smoke detection technology, event log up to 18000 events, etc., as required as per the list of approved makes attached.
Aspirating Smoke Detector: Supply, installation, testing and commissining of Single channel Fire Alarm Aspiration system with coverage up to 250sqm and sensitivity range 0.00029% obs/ft to 6.25Obs/Ft, ultrasonic flow sensing and chamber air flow monitoring for presise system healthy information, dual source optical smoke detection technology, event log up to 18000 events, etc., as required as per the list of approved makes attached.
Supply, installation, testing and commissining of power supply unit (FM approved) 110/ 220V AC to 24V DC 2Amp complete as required.
Supply and laying of ISI marked CPVC pipe of 25mm dia for aspiration complete as per specifications, as required.
Supply, installation, testing and commissioning of capillary sampling point, as per specifications as required.
Supply and fixing of END CAP for large bore 25mm etc., as required.
Electronic Hooter: Supplying installation testing and commissioning of Hooter having three distinct sounds with addressable relay module with minimum 85 db from 1Mtr distance etc. as required.
M/S SHIVA ENGINEERING AND TECHNOLOGIES PRIVATE LIMITED
FACT SYSTEMS
M/S. Safe N Secure Fire Systems
INTERACTIVE DATA SYSTEMS LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.88 MB
BOQ_171978.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .